| 2008-11-08 07:26:22 | |
| | |
| | DENIED |
| | |
| | 1) A DESIGN PROFESSIONAL THAT IS REGISTERED TO PRACTICE |
| | UNDER CHAPTER 481 OR 471 OF THE FLORIDA STATUTES SHALL |
| | AFFIX THEIR OFFICIAL SEAL, SIGNATURE AND DATE TO SAID |
| | DRAWINGS AND SPECIFICATIONS PER 106.1 FBC 2004. PHOTO |
| | COPIED, STAMPED OR REPRODUCED SIGNATURES ARE NOT |
| | ACCEPTABLE PER 61G1-16.003 F.A.C. (DOCUMENTS SHALL BE |
| | SIGNED PERSONALLY) |
| | |
| | 2) WORK ON EXISTING BUILDINGS IS COVERED UNDER THE FBC |
| | (EXISTING) AS SUCH A DESIGN PROFESSIONAL OR OWNER MUST |
| | ELECT ONE OR A COMBINATION OF LEVELS OF ALTERATION PER |
| | 301.5 FBC (EXISTING) |
| | |
| | 3) PROVIDE ATTIC ACCESS ON DRAWINGS TO ALL AREAS AS |
| | REQUIRED PER R807.1 FBC RES. |
| | |
| | 4) PROVIDE ROOF VENTILATION ON DRAWINGS THAT COMPLIES |
| | WITH R806.1 - 806.3 FBC RES. |
| | |
| | 5) THE PERMIT WAS INCORRECTLY TAKEN IN AS A ROOFING |
| | PERMIT, IT IS A RESIDENTIAL REMODEL PERMIT YOUR LICENSE |
| | NUMBER HAS BEEN CHANGED BACK TO THE CGC NUMBER ON THE |
| | PERMIT APPLICATION. THE SCOPE OF WORK WILL NEED TO |
| | INCLUDE THE ROOF COVERING AND THE ROOFING CONTRACTOR |
| | SECTION WILL NEED TO BE FILLED OUT AND A PERMIT NUMBER |
| | GENERATED FOR THE ROOFING. |
| | |
| | 6) IF THE ROOFING PERMIT IS TO BE INCLUDED ON THIS |
| | PERMIT PRODUCT APPROVALS WILL BE REQUIRED AND THEY MUST |
| | BE REVIEWED AND APPROVED BY THE DESIGNER OF RECORD |
| | (ARCHITECT) |
| | |
| | BLDG PLAN REVIEW |
| | ADRIAN MORSE |
| | 561-805-6716 |
| | |