Plan Review Details - Permit 08110028
Plan Review Stops For Permit 08110028
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2009-01-14 Cont ID  
Sent By shill Date 2009-01-14 Time 14:29 Rev Time 0.00
Received By shill Date 2009-01-14 Time 14:29 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2008-12-18 Cont ID  
Sent By shill Date 2008-12-18 Time 09:25 Rev Time 0.00
Received By shill Date 2008-12-18 Time 09:25 Sent To FIRE
Notes
2008-12-18 09:33:42****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FAC FLORIDA ADMINISTRATIVE CODE
 FS FLORIDA STATUTE
  
 1. SEE PREVIOUS LIST, FAC61G15-23.002. IF PRACTICING
 THROUGH A COMPANY, THE CERTIFICATE OF AUTHORIZATION
 NUMBER IS TO BE INCLUDED IN THE TITLE BLOCK. THIS MAY
 BE HANDWRITTEN ON THE PLAN.
  
 2. AN ELECTRIC PERMIT IS REQUIRED. ACCORDING TO OUR
 RECORDS, ALTHOUGH THIS JOB HAD A VIOLATION NOTICE
 ISSUED ON 10/28/08, AN ELECTRIC PERMIT APPLICATION HAS
 NOT BEEN MADE. PLEASE PROVIDE THE ELECTRIC PERMIT
 NUMBER OR HAVE THE ELECTRIC CONTRACTOR APPLY FOR
 PERMIT.
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-11-19 Cont ID  
Sent By shill Date 2008-11-19 Time 14:36 Rev Time 0.00
Received By shill Date 2008-11-19 Time 14:36 Sent To  
Notes
2008-11-19 14:42:35****CORRECTIONS****
 ***REVISED 12/17/8***
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FAC FLORIDA ADMINISTRATIVE CODE
 FS FLORIDA STATUTE
  
  
 1. CLARIFY SCOPE OF WORK. ARCHITECTURAL FLOOR PLANS
 WERE SUBMITTED FOR THE ENTIRE FLOOR; INDICATE WHAT WORK
 WILL BE COVERED UNDER THIS PERMIT. REVISE THE
 APPLICATION TO NOTE HOW MANY GATES (STATES
 "INSTALLATION OF GATES") TO BE CONSISTENT WITH THE
 PLANS WHICH SHOULD CLEARLY NOTE EACH GATE TO BE
 INSTALLED.
  
 2. WIND LOAD CALCS, SEE FAC61G15-23.002 AND INCLUDE ALL
 INFORMATION REQUIRED. CALCULATIONS ARE TO BE SIGNED AND
 SEALED ON EACH SHEET WITH ALL REQUIRED INFORMATION OR
 AN INDEX SHEET PROVIDED.
  
 3. PROVIDE A STRUCTURAL DETAIL SIGNED AND SEALED BY THE
 ENGINEER SHOWING COMPLIANCE WITH WIND DESIGN CRITERIA.
 FBC1609.
  
 NEW COMMENT 12/17/8
  
 4. AN ELECTRIC PERMIT IS REQUIRED.
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2009-01-13 Cont ID  
Sent By btrobaug Date 2009-01-13 Time 16:16 Rev Time 0.00
Received By btrobaug Date 2009-01-13 Time 16:11 Sent To FIRE
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2008-12-18 Cont ID  
Sent By btrobaug Date 2008-12-17 Time 16:58 Rev Time 0.00
Received By btrobaug Date 2008-12-17 Time 16:33 Sent To Z
Notes
2008-12-18 07:11:30 
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES:
  
 THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2005
 NEC, NFPA-72 2002, NFPA-101 2003, 2004 FBC AS AMENDED,
 CHAPTER 1.AND FOUND NONCOMPLIANT WITH THE FOLLOWING:
  
 REVIEW IN FAIL STATUS UNTIL AN ELECTRICAL PERMIT IS
 APPLIED FOR AND ALL ASSOCIATED FEES ARE PAID FOR
 VIOLATION OF 108.4 FBC AS AMENDED: WORK COMMENCING
 BEFORE PERMIT ISSUANCE. ANY PERSON WHO COMMENCES ANY
 WORK ON A BUILDING, STRUCTURE, ELECTRICAL, GAS,
 MECHANICAL OR PLUMBING SYSTEM BEFORE OBTAINING THE
 BUILDING OFFICIAL?S APPROVAL OR THE NECESSARY PERMITS
 SHALL BE SUBJECT TO A PENALTY OF 300 PERCENT OF THE
 USUAL PERMIT OF 100 PERCENT OF THE USUAL PERMIT FEE IN
 ADDITION TO THE REQUIRED PERMIT FEES, AS SET IN
 APPROVED SCHEDULE OF FEES.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2009-01-14 Cont ID  
Sent By mwennerg Date 2009-01-14 Time 09:46 Rev Time 0.00
Received By mwennerg Date 2009-01-14 Time 09:46 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2008-12-23 Cont ID  
Sent By mwennerg Date 2008-12-23 Time 10:40 Rev Time 0.00
Received By mwennerg Date 2008-12-23 Time 10:40 Sent To  
Notes
2008-12-23 10:46:13***DENIED***
  
 1) PLEASE SEE OTHER REVIEW COMMENTS REGARDING
 APPLICATION FOR AN ELECTRICAL PERMIT.
  
 2) PROVIDE INFORMATION THAT DESCRIBES FAILSAFE
 MECHANISM SHOULD LOSS OF POWER OCCUR.
  
  
 MIKE WENNERGREN, ASST. FIRE MARSHAL
 FIRE PLAN REVIEW
 FIRE PREVENTION (561) 804-4756

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2009-01-13 Cont ID  
Sent By adarroug Date 2009-01-13 Time 10:03 Rev Time 0.00
Received By adarroug Date 2009-01-13 Time 10:03 Sent To E
Notes
2009-01-13 10:03:37TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2008-12-17 Cont ID  
Sent By btrobaug Date 2008-12-17 Time 16:32 Rev Time 0.00
Received By btrobaug Date 2008-12-17 Time 16:32 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-11-17 Cont ID  
Sent By adarroug Date 2008-11-17 Time 16:35 Rev Time 0.00
Received By adarroug Date 2008-11-17 Time 16:35 Sent To B
Notes
2008-11-17 16:35:36TO "MISC" BOX#2

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-11-19 Cont ID  
Sent By shill Date 2008-11-19 Time 14:42 Rev Time 0.00
Received By shill Date 2008-11-04 Time 15:52 Sent To  
Notes
2008-11-04 15:53:06TO "Z" BOX

Review Stop Z ZONING
Rev No 2 Status P Date 2008-12-18 Cont ID  
Sent By mflis Date 2008-12-18 Time 08:23 Rev Time 0.00
Received By mflis Date 2008-12-18 Time 08:23 Sent To  
Notes
2008-12-18 08:24:07ZONING REVIEW: PASSED
  
 ** GATES LOCATED PER ENLARGED PLAN SUBMITTAL
  
 MATT FLIS - 822-1445

Review Stop Z ZONING
Rev No 1 Status F Date 2008-11-14 Cont ID  
Sent By btrobaug Date 2008-12-18 Time 07:01 Rev Time 0.00
Received By mflis Date 2008-11-14 Time 11:20 Sent To  
Notes
2008-11-14 11:23:29ZONING REVIEW: FAILED
  
 ** LOCATION AND PLACEMENT OF GATES IS UNCLEAR FROM
 LARGE-SCALE ARCHITECTURAL PLANS. PLEASE ADD ENLARGED
 PLAN DETAILING LOCATION OF EACH GATE, WITH DIMENSIONS,
 SHOWING PROPOSED INSTALLATION.
 ** IF ANY ADDITIONAL OPERATIONAL EQUIPMENT, SEPARATE
 FROM GATE STRUCTURE, IS TO BE PROVIDED, PLEASE NOTE
 LOCATION IN PLANS.
  
 MATT FLIS - 822-1445