| Plan Review Stops For Permit 08100666 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
P |
Date |
2009-09-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2009-09-24 |
Time |
16:54 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2009-09-24 |
Time |
16:54 |
Sent To |
|
|
| Notes |
| 2009-09-24 17:00:53 | ENGINEERED ANALYSIS CALCULATIONS WERE SUBMITTED FOR | | | INCREASED UPLIFT. REVISION TO INSTALL ENGLERT SERIES | | | 1300 METAL ROOFING IS CODE COMPLIANT. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
F |
Date |
2009-09-17 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2009-09-17 |
Time |
07:27 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2009-09-17 |
Time |
07:27 |
Sent To |
|
|
| Notes |
| 2009-09-17 07:38:56 | REVISION TO CHANGE METAL ROOFING PRODUCT APPROVAL IS | | | DENIED. THE ENGLERT SERIES 1300 METAL ROOF WITH FL # | | | 11727.5 HAS A DESIGN UPLIFT PRESSURE OF -60 PSF AND THE | | | PLANS REQUIRE -83.1 PSF IN ROOF ZONE 3. THE PRODUCT | | | LIMITATIONS REQUIRE ANY RATIONAL ANALYSIS COMPUTATIONS | | | TO BE PREPARED BY A QUALIFIED DESIGN PROFESSIONAL IN | | | COMPLIANCE WITH 2007 FBC SECTIONS 104, 105, 106. SEE | | | PAGE 4 OF 7 OF REPORT NO.08-148-1300-90-A3W-ER. SUBMIT | | | SIGNED, SEALED AND DATED CALCULATIONS FOR THIS PRODUCT | | | OR PRODUCT APPROVALS FOR ANOTHER ROOF COVERING. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2009-07-20 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2009-07-20 |
Time |
15:06 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2009-07-20 |
Time |
15:06 |
Sent To |
|
|
| Notes |
| 2009-07-20 15:07:58 | REVISED PLAN SHEETS SP-1 AND A-1 ARE OK PENDING ZONING | | | APPROVAL. | | | REVISED PLAN SHEET A-2 IS OK. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2009-07-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2009-07-09 |
Time |
12:21 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2009-07-09 |
Time |
12:21 |
Sent To |
|
|
| Notes |
| 2009-07-09 12:23:02 | REVISED PRODUCT APPROVAL FOR FLAT ROOF FROM TAMKO TO | | | GAF. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2009-05-04 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2009-05-04 |
Time |
07:52 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2009-05-04 |
Time |
07:52 |
Sent To |
|
|
| Notes |
| 2009-05-04 07:53:29 | SUBMITTED SUB-SURFACE SOIL REPORT |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2009-03-06 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2009-03-06 |
Time |
10:11 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2009-03-06 |
Time |
10:11 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2009-01-26 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2009-01-26 |
Time |
14:52 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2009-01-26 |
Time |
14:52 |
Sent To |
|
|
| Notes |
| 2009-01-26 13:52:26 | 2004 FBC W/2007 REVISIONS | | | ADDITION AND LEVEL 2 ALTERATION | | | | | | DENIED BY BUILDING | | | | | | 1) A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. FS 713 | | | | | | 2) SUBMIT A COPY OF THE PAID RECEIPT FOR THE COUNTY | | | IMPACT FEES. | | | | | | 3) THE DETAILS FOR THE CUPOLA ARE INCOMPLETE. PLEASE | | | SPECIFY THE DIMENSIONS, THE ROOF FRAMING, ROOF | | | SHEATHING, ROOF TO WALL CONNECTIONS, ETC. | | | | | | 4) THE PRODUCT APPROVAL NOA THAT WAS SUBMITTED FOR THE | | | CAST-CRETE LINTELS DOES NOT INCLUDE THE 8" WIDE LINTELS | | | WHICH ARE FOR THE 8" BLOCK WALLS. PLEASE SUBMIT THE NOA | | | FOR 8" WIDE LINTELS. DCA RULE 9B-72 | | | | | | 5) THE PRODUCT APPROVAL NOA THAT WAS SUBMITTED FOR THE | | | TAMKO MODIFIED ROOF COVERING IS FOR INSTALLATION ON | | | CONCRETE DECKS. THE FLAT ROOF OVER THE LOGGIA IS A WOOD | | | DECK. PLEASE SUBMIT THE NOA FOR WOOD DECKS. SPECIFY THE | | | ASSEMBLY, FASTENING OPTION AND DESIGN PRESSURE THAT | | | WILL BE USED. IF ENHANCED FASTENING AT CORNER AND | | | PERIMETER AREAS IS REQUIRED, SUBMIT RAS 117 | | | CALCULATIONS AS REQUIRED BY LIMITATION NUMBER 7 OF THE | | | NOA. | | | | | | NOTE: THE LETTER THAT WAS SUBMITTED IN RESPONSE TO THE | | | COMMENTS CONTAINED SEVERAL ERRORS AS TO THE SHEETS OF | | | THE PLANS WHERE THE CORRECTIONS WERE MADE. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-11-18 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2008-11-18 |
Time |
10:29 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2008-11-18 |
Time |
10:29 |
Sent To |
|
|
| Notes |
| 2008-11-18 10:25:59 | 2004 FBC W/2007 REVISIONS | | | LEVEL 2 ALTERATIONS AND ADDITION | | | | | | DENIED BY BUILDING | | | | | | 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT WILL | | | BE REQUIRED. FS 713 | | | | | | 2) IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | COPY OF RECEIPT SUBMITTED TO CITY OF | | | WEST PALM BEACH BUILDING DEPARTMENT, | | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | | | 3) ON SHEET A1 THE WALL TYPE SPECIFIED FOR THE NEW | | | POWDER ROOM #114 IS INCORRECT. DRYWALL IS SPECIFIED ON | | | THE EXTERIOR WALLS. PLEASE CORRECT. | | | | | | 4) THE MASONRY OPENING SIZES SPECIFIED FOR THE OVERHEAD | | | GARAGE DOORS IN THE DOOR SCHEDULE ON A6 ARE INCORRECT. | | | PLEASE REVISE. | | | | | | 5) SUBMIT PRODUCT APPROVALS OR DESIGN DETAILS FOR THE | | | ROOF CUPOLA. RULE 9B-72 AND FBC R801.2 | | | | | | 6) SHOW COMPLIANCE WITH R309.1 OPENING PROTECTION. | | | OPENINGS BETWEEN THE GARAGE AND RESIDENCE SHALL BE | | | EQUIPPED WITH SOLID WOOD DOORS NOT LESS THAN 1-3/8 | | | INCHES (35 MM) IN THICKNESS, SOLID OR HONEYCOMB CORE | | | STEEL DOORS NOT LESS THAN 1-3/8 INCHES (35 MM) THICK, | | | OR 20-MINUTE FIRE-RATED DOORS. | | | | | | 7) SPECIFY THE CONNECTORS THAT WILL BE USED TO ANCHOR | | | THE 2 X 8 RAFTERS TO THE EXISTING TRUSSES AT THE NEW | | | FRONT PORCH ROOF. FBC R801.2 | | | | | | 8) THE TRUSS ANCHOR NUMBERS IN THE SCHEDULE ON S4 DO | | | NOT CORRESPOND TO THE ID TAGS ON THE ROOF FRAMING | | | PLANS. PLEASE CLARIFY. FBC 106.1.1 AND R802.1.6.5 | | | | | | 9) ON S2 THE DESIGN CRITERIA SPECIFIES THE 2002 FBC AND | | | ASCE 7-98. PLEASE UPDATE TO 2004 FBC AND ASCE 7-02. SEE | | | FBC R CHAPTER 43. | | | | | | 10) THE STRUCTURAL NOTES, WIND-LOADING NOTES AND TRUSS | | | NOTES ON SHEET S5 SPECIFY ASCE 7-98. PLEASE CORRECT TO | | | ASCE 7-02. FBC R CHAPTER 43. | | | | | | 11) PROVIDE A WINDOW BUCK DETAIL. FBC R613.6.1.1 | | | | | | 12) SHOW COMPLIANCE OF STAIRS WITH R311.5.3.2 TREAD | | | DEPTH. THE MINIMUM TREAD DEPTH, EXCLUSIVE OF NOSING, | | | SHALL BE NOT LESS THAN 9 INCHES.TREADS AND RISERS OF | | | STAIRS SHALL BE PERMITTED TO BE SO PROPORTIONED THAT | | | THE SUM OF TWO RISERS AND A TREAD, EXCLUSIVE OF | | | PROJECTION OF NOSING, IS NOT LESS THAN 24 INCHES NOR | | | MORE THAN 25 INCHES. THE TREAD DEPTH SHALL BE MEASURED | | | HORIZONTALLY BETWEEN THE VERTICAL PLANES OF THE | | | FOREMOST PROJECTION OF ADJACENT TREADS AND AT A RIGHT | | | ANGLE TO THE TREAD'S LEADING EDGE. THE GREATEST TREAD | | | DEPTH WITHIN ANY FLIGHT OF STAIRS SHALL NOT EXCEED THE | | | SMALLEST BY MORE THAN 3/8 INCH. | | | | | | 13) FBC 106.3* CITY AMENDMENTS PRODUCT APPROVALS. THOSE | | | PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | | | | 14) SUBMIT TWO COPIES OF PRODUCT APPROVALS FOR THE | | | GLASS BLOCK. FAC RULE 9B-72 | | | | | | 15) NOA NO. 01-0209.03 FOR THE CAST-CRETE LINTELS | | | SPECIFIED ON SHEET S1, IS EXPIRED. PLEASE CORRECT. FAC | | | RULE 9B-72 | | | | | | 16) SPECIFY WHICH ATTACHMENT METHOD LISTED IN THE | | | PRODUCT APPROVAL NOA WILL BE USED TO ANCHOR THE | | | CONCRETE ROOF TILES. FBC R905.3.7 | | | | | | 17) PRODUCT APPROVALS WERE SUBMITTED FOR PGT HORIZONTAL | | | ROLLER WINDOWS, HOWEVER, ON SHEET A6 ALL WINDOWS ARE | | | SPECIFIED AS CASEMENT. PLEASE INDICATE WHICH WINDOWS | | | WILL BE HORIZONTAL ROLLER WINDOWS OR REMOVE THESE | | | PRODUCT APPROVALS FROM THE PACKAGE. RULE 9B-72 | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2009-10-01 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2009-10-01 |
Time |
14:38 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2009-10-01 |
Time |
14:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2009-07-24 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-07-24 |
Time |
16:28 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-07-24 |
Time |
14:59 |
Sent To |
|
|
| Notes |
| 2009-07-24 16:28:40 | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | | | THE 2007 FLORIDA RESIDENTIAL BUILDING CODE, 2009 | | | REVISIONS, 2005 NEC, 2004 FBC AS AMENDED, CHAPTER 1.AND | | | FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | | | | 1} THE RISER DIAGRAM INDICATES AN OVERHEAD FEED TO THE | | | ATS. THE RELOCATED METER AND ATS LOCATION SHOWN ON THIS | | | REVISION IS IN VIOLATION OF230.70(A)(1)***READILY | | | ACCESSIBLE LOCATION THE SERVICE DISCONNECTING MEANS | | | SHALL BE INSTALLED AT A READILY ACCESSIBLE LOCATION | | | EITHER OUTSIDE OF A BUILDING OR STRUCTURE OR INSIDE | | | NEAREST THE POINT OF ENTRANCE OF THE SERVICE | | | CONDUCTORS. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2009-03-06 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-03-06 |
Time |
15:13 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-03-06 |
Time |
14:41 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2009-01-05 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-01-05 |
Time |
14:51 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-01-05 |
Time |
09:23 |
Sent To |
P |
|
| Notes |
| 2009-01-05 11:53:29 | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | | | THE 2004 FLORIDA RESIDENTIAL BUILDING CODE, 2007 | | | REVISIONS, 2005 NEC, 2004 FBC AS AMENDED, CHAPTER 1.AND | | | FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | | | | SHEET E-5: | | | | | | 1} PER 110.9 AND 110.10: OBTAIN THE AVAILABLE FAULT | | | CURRENT AT THE UTILITY AND CALCULATE THE SAME AT THE | | | EQUIPMENT. INDICATE THE AIC RATING FOR THE EQUIPMENT IS | | | EQUAL TO OR GREATER THAN THE AVAILABLE FAULT. SHEET | | | E-5. | | | | | | 2} 702.5 CAPACITY AND RATING | | | AN OPTIONAL STANDBY SYSTEM SHALL HAVE ADEQUATE CAPACITY | | | AND RATING FOR THE SUPPLY OF ALL EQUIPMENT INTENDED TO | | | BE OPERATED AT ONE TIME. OPTIONAL STANDBY SYSTEM | | | EQUIPMENT SHALL BE SUITABLE FOR THE MAXIMUM AVAILABLE | | | FAULT CURRENT AT ITS TERMINALS.*** THE OUTPUT OF THE | | | GENERATOR IS 125 AMPS, THE CALCULATED LOAD IS 135 AMPS. | | | THE GENERATOR IS NOT RATED FOR THIS LOAD. SET A | | | SUBPANEL TO SEPARATE THE LOADS OR INCREASE THE | | | GENERATOR AMPACITY. | | | | | | 3} THE #6 GROUND RAN TO THE GROUNDING ELECTRODE IS IN | | | VIOLATION OF 250.122. THERE MUST BE AN EQUIPMENT GROUND | | | FROM THE PANEL, WHERE THE SHORT WILL BE DETECTED, TO | | | THE GENERATOR TO ENABLE THE MAIN TO TRIP UNDER A SHORT | | | CIRCUIT CONDITION.THE NEUTRAL, TO WHICH THE GENERATOR | | | "GROUND" IS CONNECTED THROUGH THE GEC, AND THE GROUND | | | WILL BE ISOLATED AFTER THE FIRST MEANS OF DISCONNECT | | | PER 210.24(A)(5), WHICH WILL BE THE ATS AS CONFIGURED | | | ON THE RISER DIAGRAM. | | | | | | 4} PROVIDE THE MANUFACTURERS SPECIFICATIONS FOR THE | | | GENERATOR AND THE TRANSFER SWITCH. NOTE: THE TRANSFER | | | SWITCH MUST HAVE AN "OFF" POSITION AS THE FIRST MEANS | | | OF DISCONNECT, AND MUST BE 200 AMP RATED WITH AN AIC | | | RATING CONCURRENT WITH THE SERVICE EQUIPMENT AND | | | GREATER THAN THE FAULT CURRENT CALCULATION. SEE COMMENT | | | #1. | | | | | | 5} CIRCUITS #9 & 11 @ 3000 VA ARE IN VIOLATION OF | | | 310.16 & 210.23(A)(1)- "CORD-AND-PLUG-CONNECTED | | | EQUIPMENT NOT FASTENED IN PLACE THE RATING OF ANY ONE | | | CORD-AND-PLUG-CONNECTED UTILIZATION EQUIPMENT NOT | | | FASTENED IN PLACE SHALL NOT EXCEED 80 PERCENT OF THE | | | BRANCH-CIRCUIT AMPERE RATING". 3000/120=25 AMPS. | | | | | | 6} CIRCUITS 3O, 32 ,34, 36 FOR THE CONDENSING UNITS | | | HAVE INCORRECT OVERCURRENT PROTECTION PER MANUFACTURERS | | | SPECIFICATIONS GIVEN ON SHEET M-5. 110.3(B). | | | | | | 7} CIRCUIT #10 INDICATES THE DISHWASHER/DISPOSER ON THE | | | SAME CIRCUIT IN VIOLATION OF 210.23(A)(1). | | | | | | NOTE: THE SMOKE DETECTOR CIRCUIT # 24 MUST BE ON AN ARC | | | FAULT BREAKER PER 210.12(B). | | | | | | SHEET E-3: | | | | | | 8} 9B-3.0472 CARBON MONOXIDE PROTECTION. (2) EVERY | | | BUILDING FOR WHICH A PERMIT FOR NEW CONSTRUCTION IS | | | ISSUED ON OR AFTER 7/1/08 AND HAVING A | | | FOSSIL-FUEL-BURNING HEATER OR APPLIANCE, A FIREPLACE, | | | OR AN ATTACHED GARAGE SHALL HAVE AN OPERATIONAL CARBON | | | MONOXIDE ALARM INSTALLED WITHIN 10 FEET OF EACH ROOM | | | USED FOR SLEEPING PURPOSES***ALTHOUGH THE DETECTOR IN | | | THE GARAGE IS RECOMMENDED AND PERMISSIBLE, THE | | | REQUIREMENT IS FOR THE HALLWAYS OUTSIDE SLEEPING ROOMS. | | | | | | 9} 680.43(A)(3) PROTECTION, SPA OR HOT TUB SUPPLY | | | RECEPTACLES THAT PROVIDE POWER FOR A SPA OR HOT TUB | | | SHALL BE GROUND-FAULT CIRCUIT-INTERRUPTER PROTECTED.*** | | | INDICATE ON PLANS. | | | | | | SHEET E-4: | | | | | | 10} 210.52(D) BATHROOMS IN DWELLING UNITS, AT LEAST ONE | | | RECEPTACLE OUTLET SHALL BE INSTALLED IN BATHROOMS | | | WITHIN 900 MM (3 FT) OF THE OUTSIDE EDGE OF EACH BASIN. | | | THE RECEPTACLE OUTLET SHALL BE LOCATED ON A WALL OR | | | PARTITION THAT IS ADJACENT TO THE BASIN OR BASIN | | | COUNTERTOP.***BATH #2 DOES NOT COMPLY WITH REQUIRED | | | SPACING. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2008-11-14 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-11-14 |
Time |
15:12 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-11-14 |
Time |
10:52 |
Sent To |
P |
|
| Notes |
| 2008-11-14 14:24:40 | | | | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | | | THE 2004 FLORIDA RESIDENTIAL BUILDING CODE, 2007 | | | REVISIONS, 2005 NEC, 2004 FBC AS AMENDED, CHAPTER 1.AND | | | FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | | | | 1} THE GENERATOR SHOWN ON THE RISER DIAGRAM MUST BE | | | LABELED AS FUTURE OR PROVIDE ALL DOCUMENTATION REQUIRED | | | FOR A RESIDENTIAL GENERATOR INSTALLATION WITH THE | | | RESUBMITTAL. | | | | | | 2} AN EQUIPMENT GROUNDING CONDUCTOR MUST BE INSTALLED | | | FROM THE FIRST MEANS OF DISCONNECT TO THE PANEL PER | | | 250.118, SIZED PER 250.122. | | | | | | 3} AN EQUIPMENT GROUNDING CONDUCTOR MUST BE INSTALLED | | | FROM THE TRANSFER SWITCH TO THE GENERATOR PER 250.122. | | | | | | 4} PANEL "A" IS LISTED AS HAVING A 225 AMP MAIN | | | BREAKER, BUT HAS A 200 AMP MAIN DISCONNECT FEEDING IT. | | | IT IS ALSO SHOWN AS BEING RECESSED , VERIFY THESE AS A | | | REVISION WOULD BE REQUIRED AT A LATER DATE NOT CORRECT. | | | | | | 5} THE A/C EQUIPMENT PANEL DESIGNATION AND CIRCUIT | | | NUMBERS ARE SHOWN IN PANEL "A" BUT LISTED IN PANEL "E". | | | CORRELATE SAME, 408.4 | | | | | | 6} 210.11(C)(3) BATHROOM BRANCH CIRCUITS IN ADDITION TO | | | THE NUMBER OF BRANCH CIRCUITS REQUIRED BY OTHER PARTS | | | OF THIS SECTION, AT LEAST ONE 20-AMPERE BRANCH CIRCUIT | | | SHALL BE PROVIDED TO SUPPLY BATHROOM RECEPTACLE | | | OUTLET(S). SUCH CIRCUITS SHALL HAVE NO OTHER OUTLETS. | | | EXCEPTION: WHERE THE 20-AMPERE CIRCUIT SUPPLIES A | | | SINGLE BATHROOM, OUTLETS FOR OTHER EQUIPMENT WITHIN THE | | | SAME BATHROOM SHALL BE PERMITTED TO BE SUPPLIED IN | | | ACCORDANCE WITH 210.23(A)(1) AND (A)(2)***CIRCUIT A-30 | | | IN THE POWDER ROOM AND OFFICE BATHROOM, SHEET E-1, AND | | | THE NEW BATH VIOLATE THE EXCEPTION AS THE LIGHT AND FAN | | | ARE ON THAT CIRCUIT | | | | | | 7} ANOTHER RECEPTACLE MUST BE ADDED IN THE NEW | | | BATHROOM, SHEET E-2, TO COMPLY WITH 210.52(D). | | | | | | 8} A SMOKE ALARM MUST BE ADDED OUTSIDE THE EXISTING | | | BEDROOM ON SHEET E-1TO COMPLY WITH R313.1.2 "OUTSIDE | | | EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY | | | OF THE BEDROOMS".. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2009-07-21 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-07-21 |
Time |
13:25 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-07-20 |
Time |
16:52 |
Sent To |
|
|
| Notes |
| 2009-07-21 13:31:31 | REVISION DENIED | | | REFERENCE: | | | FBC-2004 RESIDENTIAL | | | FBC-2004 FUEL GAS | | | | | | 1. SHT P-3 GAS RISER DIAGRAM AND GAS PIPING CHART. 2 | | | INCH PIPE IS REQUIRED FOR SECTIONS D, E, F & G ON THE | | | RISER DIAGRAM AND ON C, D, E, F, & G ON THE CHART. | | | TABLE 402.4(2). -- ALSO 1-1/4" IS REQUIRED FOR THE | | | PIPING FOR SECTIONS U & V. TABLE 402.4(2). | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2009-03-12 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2009-03-12 |
Time |
10:27 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2009-03-12 |
Time |
10:27 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2009-09-16 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-09-16 |
Time |
09:21 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-09-16 |
Time |
09:21 |
Sent To |
|
|
| Notes |
| 2009-09-16 09:21:57 | SENT TO RMCDOUGAL. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2009-09-15 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-09-15 |
Time |
15:46 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-09-15 |
Time |
15:46 |
Sent To |
|
|
| Notes |
| 2009-09-15 15:47:03 | SENT TO ZONING. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
|
Date |
2009-07-06 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-07-06 |
Time |
14:56 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-07-06 |
Time |
08:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2009-05-01 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2009-05-01 |
Time |
16:00 |
Sent To |
|
|
| Notes |
| 2009-05-01 16:00:46 | GAVE TO MCDOUGLE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2009-02-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-02-10 |
Time |
11:09 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-02-10 |
Time |
11:09 |
Sent To |
Z |
|
| Notes |
| 2009-02-10 11:09:48 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-12-23 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2009-01-26 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-12-23 |
Time |
10:55 |
Sent To |
Z |
|
| Notes |
| 2008-12-23 10:55:43 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-11-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-11-07 |
Time |
16:55 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-11-07 |
Time |
16:55 |
Sent To |
E |
|
| Notes |
| 2008-11-07 16:55:21 | TO "SFR" "E" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-11-19 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-11-19 |
Time |
09:04 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-11-03 |
Time |
11:46 |
Sent To |
|
|
| Notes |
| 2008-11-03 11:46:52 | TO "SFR" "Z" |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
P |
Date |
2009-02-23 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2009-02-23 |
Time |
17:08 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2009-02-23 |
Time |
17:14 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
2008-12-29 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2008-12-29 |
Time |
09:11 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2008-12-29 |
Time |
09:11 |
Sent To |
Z |
|
| Notes |
| 2008-12-29 09:40:57 | ***LANDSCAPE REVIEW FAILED*** | | | | | | 1. PURSUANT TO SECTION 94-442(B)(2)(A), FOR SINGLE | | | FAMILY DWELLING UNITS, AT LEAST ONE SHADE, FLOWERING OR | | | FRUIT TREE SHALL BE PLANTED FORE EACH 1200 SQUARE FEET | | | OF OPEN SPACE, OR PORTION THEREOF. BASED UPON 7,700 | | | SQUARE FEET OF OPEN SPACE, SEVEN (7) TREES ARE REQUIRED | | | AND ONLY FIVE (5) HAVE BEEN PROVIDED. | | | | | | 2. PURSUANT TO SECTION 94-442(D), PRIVATE LAND AND | | | PUBLIC RIGHTS-OF-WAY BETWEEN STREET OR SIDEWALK | | | SURFACES AND REQUIRED BUFFER STRIPS AND LANDSCAPED OPEN | | | SPACE AREAS SHALL BE PLANTED WITH GRASS. GRASS AREAS | | | SHALL BE SODDED. | | | | | | 3. PURSUANT TO SECTION 94-445(4)(G)(3), AUTOMATIC | | | IRRIGATION SYSTEMS SHALL BE USED FOR THE CULTIVATED | | | LANDSCAPE AREAS FOR ALL PROPERTIES. THE ENTIRE SITE | | | SHALL BE IRRIGATED, INCLUDING THE RIGHT-OF-WAY. | | | | | | 4. PLEASE PROVIDE THE TABULATION NECESSARY FOR THE | | | EVALUATION OF COMPLIANCE WITH ARTICLE XIV OF THE ZONING | | | AND LAND DEVELOPMENT REGULATIONS 'XERISCAPE DESIGN | | | OPTIONS'. THE LANDSCAPE PLAN MUST SATISFY A MINIMUM | | | TOTAL OF 15 POINTS FOR A SINGLE FAMILY DWELLING UNIT. | | | | | | 5. PLEASE PROVIDE SCREENING FOR THE AIR CONDITIONING | | | UNITS AND ANY OTHER MECHANICAL EQUIPMENT. | | | | | | 6. PURSANT TO SECTION 94-442(F), LANDSCAPING SHALL BE | | | INSTALLED IN ACCORDANCE WITH THE CLEAR VISION | | | REQUIREMENTS OF SUBSECTION 94-305(E). THE PROPOSED | | | HEDGE SHALL BE MOVED AWAY FROM THE CITY SIDEWALK AND BE | | | PLANTED ADJACENT TO THE CIRCULAR DRIVEWAY. THIS WILL | | | OPEN UP THE VISTA TO THE DRIVER WHEN EXIITING THE | | | DRIVEWAY. | | | | | | 7. PLEASE PROVIDE A PLANT LIST WITH THE PLANT NAMES, | | | QUANTITY, SIZE AND SPACING OF ALL PROPOSED PLANT | | | MATERIAL. | | | | | | 8. SHOW ALL OVERHEAD LINES, OVERHANGING TREE LIMBS, | | | EASEMENTS AND UTILITIES ON THE LANDCAPE PLAN TO AVOID | | | CONFLICTS. | | | | | | 9. STAFF RECOMMENDS THAT LANDSCAPING BE INSTALLED ALONG | | | THE FRONT BUILDING ELEVATION. | | | | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT | | | KUSSNER @ (561) 822-1462. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2009-09-10 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-09-10 |
Time |
13:29 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-09-10 |
Time |
07:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2009-07-17 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-07-17 |
Time |
16:36 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-07-17 |
Time |
16:35 |
Sent To |
|
|
| Notes |
| 2009-07-17 16:36:19 | REVISED M3 DELTA 6 M4 DELTA 2 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2009-03-16 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2009-03-16 |
Time |
09:09 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2009-03-16 |
Time |
09:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2009-01-26 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2009-01-26 |
Time |
10:32 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2009-01-26 |
Time |
10:23 |
Sent To |
|
|
| Notes |
| 2009-01-26 10:31:22 | 01/26/09 | | | PLEASE PROVIDE TRANSFER DUCT SIZE ON PLANS SECTION | | | M1602.4 BALANCED RETURN AIR # 2 . 2004 RFBC | | | PLEASE REFER TO SECTION 13 609.1.ABC.1 IN REGARDS TO | | | FRESH AIR INTAKE DETAIL PAGE M-5 | | | PLAN REVIEW BY HAROLD MOSER 161-805-6732 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2008-11-04 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-11-04 |
Time |
13:33 |
Rev Time |
1.30 |
| Received By |
tgordon |
Date |
2008-11-04 |
Time |
13:33 |
Sent To |
Z |
|
| Notes |
| 2008-11-04 14:31:23 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | *** DENIED *** | | | | | | 1) ENERGY CALCULATIONS NEED TO BE ON FORM 600A-04R, SEE | | | 2004 FBC 13-600.3.A (12-8-06 REVISION). | | | | | | 2) ENERGY CALCULATIONS LINE 6 NEEDS TO SHOW THE TOTAL | | | SQUARE FEET UNDER AIR FOR THE HOUSE, SEE 2004 FBC | | | 13-600.0 METHOD A AND 13-600.2.A.3.2. | | | | | | 3) ENERGY CALCULATIONS LINE 8A SHOWS R-6 ON SLABS EDGE, | | | PLANS SHOW NO INSULATION ON SLABS EDGE. THE TWO MUST | | | COINCIDE, PLEASE CORRECT SEE 2004 FBC 13-605.1.ABC.1.2. | | | | | | 4) ENERGY CALCULATIONS LINE 9A SHOWS R-11 ON CONCRETE | | | WALLS, PLANS SHOW R-4.1 ON THE CONCRETE WALLS. THE TWO | | | MUST COINCIDE, PLEASE CORRECT PER 2004 FBC 13-103.3. | | | | | | 5) ENERGY CALCULATIONS LINE 10A SHOWS UNDER ATTIC, | | | PLANS SHOW ICYNENE BEING INSTALLED UNDER THE ROOF THIS | | | WOULD BE A SINGLE ASSEMBLY, PLEASE CORRECT SEE 2004 FBC | | | 13-604.2.A.1. | | | | | | 6) ENERGY CALCULATIONS LINE 12A SHOWS A 60,000 BTU A/C | | | SYSTEM IS BEING INSTALLED, MECHANICAL PLANS SHOW THREE | | | SYSTEM BEING INSTALLED ONE 3.5 TON AND TWO 2 TON | | | SYSTEMS, PLEASE CORRECT PER 2004 FBC-103.3. DO SAME FOR | | | LINE 13A HEATING SYSTEMS. | | | | | | 7) ENERGY CALCULATIONS LINE 14C IS TAKING THE CREDIT | | | FOR H.R.U. (HEAT RECOVERY UNIT). PLEASE SUBMIT DETAILED | | | MANUFACTURER'S SPECIFICATION'S FOR THE UNIT AND SHOW | | | WERE THE UNIT WILL BE INSTALLED ON THE MECHANICAL PLAN. | | | SEE 2004 FBC 13-612.2.A.3.1. | | | | | | 8) THE COOLING LOAD CALCULATIONS SUBMITTED ARE ONLY FOR | | | ONE ZONE. PLEASE SUBMIT COOLING LOAD CALCULATIONS FOR | | | ALL THREE ZONES, PER 2004 FBC 13-607.1.ABC.1. | | | | | | 9) MECHANICAL PLAN M-1 SHOWS THE CONDENSATE LINE FROM | | | A.H.U. #1 DISCHARGING ON THE FRONT PORCH. THE | | | CONDENSATE WATER MAY NOT DISCHARGE THERE, PLEASE | | | CORRECT PER 2004 FBC/R M1411.3. | | | | | | 10) A/C SYSTEM MODEL NUMBERS AHU TWE040E CU TWX042D100A | | | AND AHU TWE031E CU TWX024C100A LISTED ON THE A/C | | | EQUIPMENT SCHEDULE COULD NOT BE FOUND ON THE ARI | | | DIRECTORY WEB-SITE, PLEASE CORRECT OR SUBMIT AN ARI | | | CERTIFICATE, SEE 2004 FBC 13-607.1.ABC.3.1.1. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2009-07-21 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-07-21 |
Time |
13:31 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-07-20 |
Time |
16:52 |
Sent To |
|
|
| Notes |
| 2009-07-21 13:38:10 | REVISIONS OK SHEETS P-3, P-4 & P-5. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2009-03-12 |
Time |
|
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2009-03-10 |
Time |
14:42 |
Sent To |
G |
|
| Notes |
| 2009-03-10 15:08:49 | PLUMBING PLAN REVIEW: | | | | | | 1. OK | | | 2. OK | | | 3. OK | | | 4. OK | | | 5. OK | | | 6. OK | | | 7. OK | | | 8. OK | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2009-01-20 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2009-01-20 |
Time |
10:25 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2009-01-16 |
Time |
10:46 |
Sent To |
|
|
| Notes |
| 2009-01-20 10:12:33 | PLUMBING PLAN REVIEW: | | | DENIED: | | | | | | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | | GAS/PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE. | | | | | | 1. OK | | | 2. OK | | | 3. OK | | | 4. SHEET P-6 WATER RISER DIAGRAM - PLEASE SHOW WATER | | | HAMMER ARRESTORS AT DISH WASHER AND ICE MAKER (2). | | | (A) 604.9 WATER HAMMER. A WATER-HAMMER | | | ARRESTOR SHALL BE INSTALLED WHERE | | | QUICK-CLOSING VALVES ARE UTILIZED. | | | 5. OK (NOTE: RELIEF TO BE INSTALLED IF REQUIRED BY | | | TANKLESS MANUFACTURER). | | | NEW: | | | 6. SHEET P-6 GAS RISER - 1. SUBMIT AN ISOMETRIC DRAWING | | | THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2004 | | | FUEL GAS CODE. | | | 7. INDICATE THE DELIVERY PRESSURE (PSI) | | | PER FBC-2004 FUEL GAS CODE SEC. 402.2. | | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. (P-3 INDICATES | | | PRESSURE AS LESS THAN 2 PSI. PRESSURE SHOULD BE LESS | | | THAN 0.5 PSI OR 2 PSI). | | | 8. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2004 FUEL GAS CODE SEC 402.2 | | | | | | ********IMPORTANT INFORMATION******** | | | WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE | | | OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW | | | PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | END OF COMMENTS: | | | | | | *IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | LARRY WAGNER | | | (561)805-6692 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2008-11-19 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-11-19 |
Time |
08:55 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-11-18 |
Time |
16:56 |
Sent To |
|
|
| Notes |
| 2008-11-19 09:03:39 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | | | | 1. SHT P-1 SANITARY RISER DIAGRAM. THE AUTOMATIC | | | CLOTHES WASHER FIXTURE DRAIN SHALL CONNECT TO A BRANCH | | | DRAIN OR DRAINAGE STACK A MINIMUM OF 3 INCHES IN | | | DIAMETER. SECTION 406.3. | | | | | | 2. SHT P-1 SANITARY RISER DIAGRAM. THE CLEANOUT BEHIND | | | THE W/M SHALL BE INSTALLED A MINIMUM 4 FEET ABOVE | | | FINISHED FLOOR FOR ACCESS. SECTION 708.9 | | | | | | 3. SHT P-1 FLOOR PLAN AND SANITARY RISER DIAGRAM. | | | PLEASE SHOW THE CLEANOUTS REQUIRED BY SECTIONS 708.3.4 | | | & 708.3.5, AT THE BASE OF EACH STACK AND NEAR THE | | | JUNCTION OF THE BUILDING DRAINS AND THE BUILDING SEWER. | | | | | | 4. SHT P-2 WATER RISER DIAGRAM. WATER HAMMER ARRESTORS | | | ARE REQUIRED ON THE SUPPLY LINES TO THE DISHWASHER AND | | | THE ICE MAKER IN THE KITCHEN AREA. SECTION 604.9. | | | | | | 5. SHT P-2 WATER RISER DIAGRAM. THE RELIEF VALVE | | | DISCHARGE FOR THE WATER HEATER SHALL NOT HAVE ANY | | | TRAPPED SECTIONS AND SHALL HAVE A VISIBLE AIR GAP OR | | | AIR GAP FITTING LOCATED IN THE SAME ROOM AS THE WATER | | | HEATER. SECTION 504.6.1. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
F |
Date |
2009-07-23 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2009-07-23 |
Time |
14:30 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2009-07-23 |
Time |
14:27 |
Sent To |
|
|
| Notes |
| 2009-07-23 14:30:07 | PLANNING AND ZONING DEPT: ***ZONING FAILED*** | | | | | | 1. PLEASE PROVIDE ALL RESPONSES IN WRITING. | | | | | | 2. INDICATE SETBACK DIMENSIONS FROM THE PROPOSED | | | GENERATOR EQUIPMENT TO ALL PROPERTY LINES. PURSUANT THE | | | CITY OF WEST PALM BEACH ZONING AND LAND DEVELOPMENT | | | REGULATIONS (ZLDR), SECTION 94-305(B)(4): MECHANICAL | | | EQUIPMENT MAY NOT PROJECT MORE THAN 4 FEET INTO A | | | REQUIRED SETBACK. | | | | | | NOTE: THE SUBMITTAL OF THE REQUESTED INFORMATION MAY | | | GENERATE ADDITIONAL COMMENTS. | | | | | | FOR ADDITIONAL INFORMATION, THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT | | | WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH | | | PLANNING DEPARTMENT WEBSITE AT | | | WWW.CITYOFWPB.COM/PLAN/INDEX.HTM. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | | CONTACT ME. | | | | | | MAGGIE CRUZ, ASSOCIATE PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: (561) 822-1444 OR (561) 805-6720 | | | E-MAIL: [email protected] | | | | | | PLACED BACK ON R10 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2009-02-23 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2009-02-23 |
Time |
18:02 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2009-02-23 |
Time |
17:40 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2008-12-29 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2009-02-23 |
Time |
17:14 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2008-12-26 |
Time |
13:24 |
Sent To |
E |
|
| Notes |
| 2008-12-29 11:30:10 | PLANNING AND ZONING DEPT: ***ZONING FAILED*** | | | | | | 1. PLEASE PROVIDE ALL RESPONSES IN WRITING. | | | | | | 2. PLEASE COMPLY WITH THE LANDSCAPE PLAN REVIEWER | | | COMMENTS. | | | | | | NOTE: THE SUBMITTAL OF THE REQUESTED INFORMATION MAY | | | GENERATE ADDITIONAL COMMENTS. | | | | | | FOR ADDITIONAL INFORMATION, THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT | | | WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH | | | PLANNING DEPARTMENT WEBSITE AT | | | WWW.CITYOFWPB.COM/PLAN/INDEX.HTM. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | | CONTACT ME. | | | | | | MAGGIE CRUZ, ASSOCIATE PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: (561) 822-1444 OR (561) 805-6720 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2009-01-26 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2008-11-07 |
Time |
15:41 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2008-11-07 |
Time |
15:39 |
Sent To |
I |
|
| Notes |
| 2008-11-07 15:41:38 | PLANNING AND ZONING DEPT: ***ZONING FAILED*** | | | | | | 1. PLEASE PROVIDE ALL RESPONSES IN WRITING. | | | | | | 2. PURSUANT TO THE CITY OF WEST PALM BEACH ZONING AND | | | LAND DEVELOPMENT REGULATIONS (ZLDR), SECTION | | | 94-441(C)(2): AS THE VALUE OF THE PROPOSED WORK EXCEEDS | | | 50% OF THE STRUCTURE'S VALUE (LISTED AS "IMPROVEMENT | | | VALUE" WITH THE P.B.C. PROPERTY APPRAISER'S OFFICE), | | | LANDSCAPING SHALL BE IN COMPLIANCE WITH ALL APPLICABLE | | | REGULATIONS FOUND IN ARTICLE XIV OF THE ZLDR. | | | | | | PLEASE SUBMIT TWO (2) COPIES OF A LANDSCAPE PLAN | | | SHOWING COMPLIANCE WITH SECTIONS 94-442 AND 94-445 OF | | | THE ZLDR. | | | | | | FOR ADDITIONAL INFORMATION, THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT | | | WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH | | | PLANNING DEPARTMENT WEBSITE AT | | | WWW.CITYOFWPB.COM/PLAN/INDEX.HTM. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | | CONTACT ME. | | | | | | MAGGIE CRUZ, ASSOCIATE PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: (561) 822-1444 OR (561) 805-6720 | | | E-MAIL: [email protected] | | | |
|
|