Plan Review Details - Permit 08100551
| Plan Review Stops For Permit 08100551 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-11-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-11-13 |
Time |
15:39 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-11-13 |
Time |
15:39 |
Sent To |
E |
|
| Notes |
| 2008-11-13 15:53:54 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2004 | | | FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FS FLORIDA STATUTE | | | | | | | | | | | | 1. IMPORTANCE FACTOR OF 1.0 TO BE USED IN ENGINEERING | | | CALCULATIONS, FBC R301. THIS IMPROVEMENT AFFECTS THE | | | INTEGRITY OF THE ROOF OF A RESIDENCE. | | | | | | 2. DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED FOR | | | PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED ORIGINALS | | | FS471. | | | | | | 3. GOVERNING CODE SHOULD INCLUDE 2007 | | | REVISIONS/SUPPLEMENTS. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2008-11-14 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-11-14 |
Time |
08:54 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-11-14 |
Time |
08:34 |
Sent To |
I |
|
| Notes |
| 2008-11-14 08:54:06 | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | | | THE 2004 FLORIDA RESIDENTIAL BUILDING CODE, 2007 | | | REVISIONS, 2005 NEC, 2004 FBC AS AMENDED, CHAPTER 1.AND | | | FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | | | | 1} THE VALUE ON THE APPLICATION MUST INCLUDE THE TOTAL | | | COST OF LABOR AND MATERIAL. VALUATION REFERENCES MAY | | | INCLUDE THE LATEST PUBLISHED DATA OF NATIONAL | | | CONSTRUCTION COST ANALYSIS SERVICES PER 108.3 FBC AS | | | AMENDED. | | | | | | A PERMIT SHALL NOT BE ISSUED UNTIL FEES AUTHORIZED | | | UNDER SECTION 553.80, FLORIDA STATUTES, HAVE BEEN PAID. | | | 108.1 FBC. | | | | | | ADJUST THE VALUE AT THE PERMIT CLERK?S DESK, AND PAY | | | THE DIFFERENCE IN FEES PRIOR TO RESUBMITTING. | | | | | | 2} INDICATE SYSTEM MANUFACTURER AND MODEL PANELS ARE | | | INTENDED TO BE USED. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-11-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-11-07 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-11-07 |
Time |
13:59 |
Sent To |
B |
|
| Notes |
| 2008-11-07 13:59:46 | TO "MISC' BOX#3 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-11-14 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-11-14 |
Time |
08:55 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-10-24 |
Time |
11:56 |
Sent To |
PC |
|
| Notes |
| 2008-11-03 11:58:23 | TO $5000.00 OR LESS "P" BOX, HOWEVER OTHER PLAN REVIEWS | | | ARE REQUIRED. *MRPERSON. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2008-11-03 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-11-03 |
Time |
13:18 |
Rev Time |
1.00 |
| Received By |
mperson |
Date |
2008-11-03 |
Time |
13:18 |
Sent To |
Z |
|
| Notes |
| 2008-11-03 13:38:18 | PLUMBING PLAN REVIEW: | | | DENIED: | | | | | | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | | PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE. | | | | | | 1. THE "FLORIDA SOLAR ENERGY CENTER, APPROVED SOLAR | | | ENERGY SYSTEM" SHEET IS INDICATING SEVENTEEN DIFFERENT | | | MODEL NUMBERS FOR THE COLLECTOR MANUFACTURER AND THREE | | | CONTROLLER MANUFACTURER'S. CLEARLY INDICATE ON THE | | | RESUBMITTAL WHICH MODEL NUMBER COLLECTOR AND CONTROLLER | | | ARE BEING USED ON THE PROPOSED SOLAR POOL. PER FBC-2004 | | | CHAPTER 1, (W.P.B.) AS AMENDED SECTION 106.1.2 | | | ADDITIONAL DATA. | | | | | | 2. NOTE: ALL PLANS, SPECIFICATIONS, AND ACCOMPANYING | | | DATA BEING FILED FOR PUBLIC RECORD SHALL CONTAIN THE | | | PRINTED NAME OF THE RESPONSIBLE PERSON WITH THE | | | ORIGINAL SIGNATURE AND DATE ON SUCH INFORMATION. PER | | | FBC-2004 CHAPTER 1, (W.P.B. AS AMENDED SECTION | | | *106.3.4.3. | | | IF THE DESIGN PROFESSIONAL IS AN ARCHITECT OR ENGINEER, | | | THEN HE OR SHE SHALL AFFIX HIS OR HER OFFICIAL SEAL, | | | SIGNATURE AND DATE TO SAID DRAWINGS, PER FLORIDA | | | STATUTES 481 AND 471 RESPECTIVELY. | | | *THE CONTRACTOR OF RECORD MAY BE THE DESIGN | | | PROFESSIONAL IF EXEMPTIONS UNDER FLORIDA STATUTES | | | 471.003(H) APPLY. | | | | | | 3. THE VALUE ON THE PERMIT APPLICATION APPEARS LOW FOR | | | (9) 4' X 12' PANELS. THE VALUE ON THE PERMIT | | | APPLICATION MUST INCLUDE THE TOTAL COST OF LABOR, | | | MATERIALS AND DESIGN. | | | PER (W.P.B AS AMENDED) SECTION 108.3 BUILDING PERMIT | | | VALUATION. IF, IN THE OPINION OF THE BUILDING OFFICIAL, | | | THE CLAIMED VALUATION OF BUILDING, ALTERATION, | | | STRUCTURAL, ELECTRICAL, GAS, MECHANICAL OR PLUMBING | | | SYSTEMS APPEARS TO BE UNDERESTIMATED ON THE | | | APPLICATION, THE PERMIT SHALL BE DENIED. | | | | | | 4. PER FS 713.13 (1) THRU (6): A NOTICE OF COMMENCEMENT | | | IS REQUIRED FROM THE - PALM BEACH COUNTY COURTHOUSE - | | | 4TH FLOOR RECORDING DEPT. 205 N. DIXIE HWY., BEFORE THE | | | FIRST INSPECTION. PER FS 713.13 (2): IF THE IMPROVEMENT | | | DESCRIBED IN THE NOTICE OF COMMENCEMENT IS NOT ACTUALLY | | | COMMENCED WITHIN 90 DAYS AFTER THE RECORDING THEREOF, | | | SUCH NOTICE IS VOID AND OF NO FURTHER EFFECT. | | | | | | END OF COMMENTS: | | | | | | *IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2008-11-07 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2008-11-07 |
Time |
11:08 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2008-11-07 |
Time |
11:03 |
Sent To |
I |
|
| Notes |
| 2008-11-07 11:08:11 | PLANNING AND ZONING DEPT: ***ZONING FAILED*** | | | | | | 1. PLEASE PROVIDE ALL RESPONSES IN WRITING. | | | | | | 2. PROVIDE AN ELEVATION OF THE BUILDING AND INDICATE | | | THE HEIGHT DIMENSIONS INCLUDING THE SOLAR PANEL. NOTE: | | | PURSUANT TO THE CITY OF WEST PALM BEACH ZONING AND LAND | | | DEVELOPMENT REGULATIONS, SECTION 94-306(A): HEIGHT | | | EXCEPTIONS. EXEMPTIONS TO HEIGHT LIMITS. HEATING, | | | VENTILATION, AND AIR CONDITIONING EQUIPMENT; CHURCH | | | STEEPLES, BELL TOWERS, FLAG POLES, CHIMNEYS, PARAPETS, | | | STAIR ENCLOSURES, TANKS, DECORATIVE FEATURES, ELEVATOR | | | HOISTWAYS OR EQUIPMENT, TELEVISION OR RADIO ANTENNAS, | | | AND RELATED MECHANICAL OR FUNCTIONAL FEATURES MAY | | | EXCEED DISTRICT HEIGHT REQUIREMENTS BY TEN PERCENT. | | | | | | FOR ADDITIONAL INFORMATION, THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT | | | WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH | | | PLANNING DEPARTMENT WEBSITE AT | | | WWW.CITYOFWPB.COM/PLAN/INDEX.HTM. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | | CONTACT ME. | | | | | | MAGGIE CRUZ, ASSOCIATE PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: (561) 822-1444 OR (561) 805-6720 | | | E-MAIL: [email protected] | | | |
|
|
|