| Plan Review Stops For Permit 08100489 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2008-12-08 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-12-08 |
Time |
16:08 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-12-08 |
Time |
16:08 |
Sent To |
|
|
| Notes |
| 2008-12-08 16:08:49 | NEW SHEETS #2 AND #3 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2008-10-30 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-10-30 |
Time |
09:39 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-10-30 |
Time |
09:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2008-12-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-12-05 |
Time |
11:11 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-12-05 |
Time |
11:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2008-11-04 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-11-04 |
Time |
08:14 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-11-04 |
Time |
08:14 |
Sent To |
|
|
| Notes |
| 2008-11-04 08:14:12 | | | | | | | | | | | | | ** DENIED REVIEW ** | | | | | | 1) NOTE: PLEASE INCLUDE NEW OR EXISTING HORNS, STROBES, | | | HORN/STROBE DEVICES MEETING FBC 11-4.28.1, .2 AND .3. | | | PLEASE LIST THE HEIGHTS AND LEVELS. | | | | | | 2) NOTE: PLEASE INCLUDE THE LIGHTING PERFORMANCE | | | CALCULATIONS PER 13-415.2, 13-415.2.ABC.1.1,.1.2. | | | THESE WOULD BE FOR NEW AREAS ONLY AND MAY BE SHOWN ON | | | PLANS FOR TABLE 13-415.2.B | | | PLEASE BE SURE TO COMPLETE THE FIXTURE LEGEND. | | | | | | **IMPORTANT** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED | | | INTO TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2008-12-10 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-12-10 |
Time |
11:25 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-12-10 |
Time |
11:06 |
Sent To |
|
|
| Notes |
| 2008-12-10 11:22:51 | *****APPROVED***** | | | | | | | | | PLANS WERE PREVIOUSLY APPROVED ON 10/30/2008; | | | NEW/REPLACED SHEETS A-2, A-3, A-4, & E-1 WERE STAMPED, | | | INITIALED, AND DATED IN ADDITION TO PREVIOUSLY | | | FIRE-STAMPED A-1. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2008-10-30 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-10-30 |
Time |
13:50 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-10-30 |
Time |
13:50 |
Sent To |
|
|
| Notes |
| 2008-10-30 13:53:17 | SEPARATE SHOP DARWINGS AND PERMIT REQUIRED FOR FIRE | | | SPRINKLER REMODEL. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-12-15 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2008-12-15 |
Time |
13:47 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2008-12-02 |
Time |
13:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-12-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-11-14 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2008-10-22 |
Time |
16:33 |
Sent To |
|
|
| Notes |
| 2008-10-22 16:35:57 | TO "BOB"#9 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2008-12-14 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-12-14 |
Time |
11:08 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-12-14 |
Time |
11:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2008-10-28 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-10-28 |
Time |
12:04 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2008-10-28 |
Time |
11:43 |
Sent To |
|
|
| Notes |
| 2008-10-28 12:03:55 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | *** DENIED *** | | | | | | 1) PLEASE STATE ON MECHANICAL PLAN HOW THE BATHROOM | | | EXHAUST FANS ARE BEING CONTROLLED TO PREVENT THE A/C | | | SUPPLY AIR FROM ENTERING THE SPACE WHEN THE EXHAUST | | | FANS ARE NOT RUNNING AND BEING RETURNED TO THE A/C | | | SYSTEM THROUGH THE MAKE-UP TRANSFER DUCT, SEE 2004 | | | FBC/M 403.2.1 (3) AND 407.1. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
N |
Date |
2008-12-15 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-12-15 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-12-15 |
Time |
11:06 |
Sent To |
|
|
| Notes |
| 2008-12-15 11:07:25 | RENOVATION ONLY -- NO ALTERATION INDICATED |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2008-10-31 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-10-31 |
Time |
14:35 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-10-31 |
Time |
14:35 |
Sent To |
|
|
| Notes |
| 2008-10-31 15:17:06 | PLUMBING PLAN REVIEW: | | | DENIED: | | | | | | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | | PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE. | | | | | | 1. SHEET A-2 SCOPE OF WORK (RESTROOMS): CLEARLY | | | INDICATE IN THE SCOPE OF WORK THE ADDITION OF ONE | | | LAVATORY SINK IN THE WOMENS BATHROOM FOR THE 7TH FLOOR | | | AND ALSO PROVIDE SANITARY AND POTABLE WATER RISER | | | DIAGRAMS FOR THE PROPOSED LAVATORY. PER FBC-2004 | | | CHAPTER 1, (W.P.B. AS AMENDED) SECTION 106.3.5.1.3 | | | PLUMBING (3)(4)(13). | | | | | | 2. SHEET A-3 SCOPE OF WORK (RESTROOMS): CLEARLY | | | INDICATE IN THE SCOPE OF WORK THE ADDITION OF ONE | | | LAVATORY SINK IN THE WOMENS BATHROOM FOR THE 9TH FLOOR | | | AND ALSO PROVIDE A SANITARY AND POTABLE WATER RISER | | | DIAGRAM FOR THE PROPOSED LAVATORY. PER FBC-2004 CHAPTER | | | 1, (W.P.B. AS AMENDED) SECTION 106.3.5.1.3 PLUMBING | | | (3)(4)(13). | | | | | | ********IMPORTANT INFORMATION******** | | | WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE | | | OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW | | | PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | END OF COMMENTS: | | | | | | *PLEASE CALL IF THERE ARE ANY QUESTIONS. | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | PHONE= (561) 805-6730 | | | FAX= (561) 805-6731 | | | E-MAIL= [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2008-11-04 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2008-11-04 |
Time |
09:12 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2008-11-04 |
Time |
09:12 |
Sent To |
|
|
| Notes |
|
|