| Plan Review Stops For Permit 08100428 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2009-04-07 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2009-04-07 |
Time |
16:22 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2009-04-07 |
Time |
16:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2009-02-12 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2009-02-12 |
Time |
08:31 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2009-02-12 |
Time |
08:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2008-12-02 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-12-02 |
Time |
09:47 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-12-02 |
Time |
09:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-10-28 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-10-28 |
Time |
12:33 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-10-28 |
Time |
12:33 |
Sent To |
|
|
| Notes |
| 2008-10-28 12:33:51 | BUILDING PLAN REVIEW | | | PERMIT: 08100428 | | | ADD: 1525 N. FLAGLER DR. #100 | | | CONT: MORGAN CONTRACTING GROUP INC. | | | TEL: (561)330-9600 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 10-28-08 | | | REVIEW: 1ST | | | ACTION: DENIED | | | | | | 1) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE & REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 2) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) AFTER | | | JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC | | | BUILDING WITH THE 2007 SUPPLEMENTS. THIS INFORMATION | | | SHALL BE INDICATED ON THE PLANS. | | | | | | 3) FBC 1210.2 WALLS WITHIN 2 FEET OF URINALS AND WATER | | | CLOSETS SHALL HAVE A SMOOTH, HARD, NONABSORBENT | | | SURFACE, TO A HEIGHT OF 4 FEET ABOVE THE FLOOR. NOTE: | | | PAINT ON DRYWALL IS NOT CONSIDERED A HARD SURFACE. | | | | | | 4) FBC 11-7.1(2) (I) A PORTION OF THE MAIN COUNTER | | | SHALL HAVE A MINIMUM LENGTH OF 36 INCHES AND A MAXIMUM | | | HEIGHT OF 36 INCHES. SHEET A3.1 #3 SHOWS THE RECEPTION | | | DESK HEIGHT AT 3?- 6?. | | | | | | 5) SHEET A1.0 DOOR #3 CLEARANCE SHALL MEET THE | | | REQUIREMENTS OF 11-4.13.6 MANEUVERING CLEARENCES AT | | | DOORS. MINIMUM MANEUVERING CLEARANCES AT DOORS THAT ARE | | | NOT AUTOMATIC OR POWER-ASSISTED SHALL BE AS SHOWN IN | | | FIG. 25. THE FLOOR OR GROUND AREA WITHIN THE REQUIRED | | | CLEARANCES SHALL BE CLEAR & LEVEL. NOTE: 18? MINIMUM. | | | | | | | | | | | | 6) (2004 FBC) 106.1.1 INFORMATION ON CONSTRUCTION | | | DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL BE OF | | | SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE & | | | EXTENT OF THE WORK PROPOSED & SHOW IN DETAIL THAT IT | | | WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | | RELEVANT LAWS, ORDINANCES, AND RULES AND REGULATIONS AS | | | DETERMINED BY THE BUILDING OFFICIAL. THE PLANS NEED TO | | | CLEARLY SHOW THE EXISTING WALLS AND THE NEW WALLS. | | | PROVIDE A WALL LEGEND TO SHOW THIS ASPECT OF THE PLANS. | | | | | | 7) ROOM 108 ON SHEET A1.0 WHERE THE DOOR IS REMOVED, IS | | | THAT AN EXTERIOR WALL OR A PARTITION WALL WHICH NEEDS A | | | FIRE RATING? IF THAT IS A PARTITION WALL, STATE THE UL | | | NUMBER FOR THE NEW WALL. THERE IS NO WALL TYPE | | | INDICATED. | | | | | | 8) SHOW THE FOLLOWING INFORMATION FOR THE BREAK ROOM | | | SINK ON THE PLANS. FBC 11-4.24.2. SINKS SHALL BE | | | MOUNTED WITH THE COUNTER OR RIM NO HIGHER THAN 34" | | | ABOVE THE FINISH FLOOR. 11-4.24.3 KNEE CLEARANCE THAT | | | IS AT LEAST 27" HIGH 30" WIDE, AND 19" DEEP SHALL BE | | | PROVIDED UNDERNEATH SINKS. 11-4.24.5 CLEAR FLOOR SPACE. | | | A CLEAR FLOOR SPACE AT LEAST 30 INCHES BY 48 INCHES | | | COMPLYING WITH SECTION 11-4.2.4 SHALL BE PROVIDED IN | | | FRONT OF A SINK TO ALLOW FORWARD APPROACH. THE CLEAR | | | FLOOR SPACE SHALL BE ON AN ACCESSIBLE ROUTE AND SHALL | | | EXTEND A MAXIMUM OF 19 INCHES UNDERNEATH THE SINK. | | | | | | 9) SHEET A1.0 ACCESSIBLE TOILET SHOWS TWO DIFFERENT | | | TYPES OF WALL SYMBOLS IN BACK OF THE WATER CLOSET. WILL | | | THERE BE A TYPE P-1 AND A TYPE P-2 WALL CONSTRUCTED IN | | | THIS AREA? STATE HOW THE TOP AND BOTTOM TRACK WILL BE | | | FASTENED TO THE STRUCTURE. CLARIFY. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | (561)805-6726 | | | [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2009-08-14 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-08-14 |
Time |
11:45 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-08-14 |
Time |
11:18 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2009-02-10 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-02-10 |
Time |
12:20 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-02-10 |
Time |
11:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2008-12-08 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-12-08 |
Time |
08:28 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-12-04 |
Time |
13:18 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2008-10-24 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-10-24 |
Time |
15:23 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-10-24 |
Time |
14:48 |
Sent To |
|
|
| Notes |
| 2008-10-24 15:15:39 | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2005 | | | NEC, NFPA-72 2002, NFPA-101 2003, 2004 FBC AS AMENDED, | | | CHAPTER 1.AND FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | | | | 1} THIS PROJECT MUST COMPLY WITH CHAPTER 13 FBC. SEE | | | 13-415.1ABC.1.1FOR TIME CLOCK REQUIREMENTS AND FOR | | | LIGHTING DENSITIES. ALL THAT IS REQUIRED FOR THE | | | ELECTRICAL REVIEW IS THE BASIC PRESCRIPTIVE | | | REQUIREMENTS. SEE 13-415.2.ABC.1 PERFORMANCE | | | CALCULATION PROCEDURES, GENERAL. | | | THE INTERIOR LIGHTING POWER ALLOWANCE FOR A BUILDING OR | | | A SEPARATELY METERED OR PERMITTED PORTION OF A BUILDING | | | SHALL BE DETERMINED BY EITHER THE BUILDING AREA METHOD | | | DESCRIBED IN SECTION 415.2.C.1 OR THE SPACE-BY-SPACE | | | METHOD DESCRIBED IN SECTION 415.2.B.1. THE INSTALLED | | | INTERIOR LIGHTING POWER IDENTIFIED IN ACCORDANCE WITH | | | SECTION 415.2.ABC.1.1 SHALL NOT EXCEED THE INTERIOR | | | LIGHTING POWER ALLOWANCE DEVELOPED IN ACCORDANCE WITH | | | SECTION 415.2.C.1 OR 415.2.B.1. THIS CAN BE | | | DEMONSTRATED ON THE PLANS INDICATING THE WATTAGES OF | | | THE LUMINAIRES CHOSEN FOR THE PROJECT CONFORM TO THE | | | DENSITY REQUIREMENTS. INDICATE WATTAGES ON THE FIXTURE | | | SCHEDULE TO CORRELATE WITH THE ONES IN THE | | | CALCULATIONS. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2009-04-09 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2009-04-09 |
Time |
14:51 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2009-04-09 |
Time |
14:43 |
Sent To |
|
|
| Notes |
| 2009-04-09 14:53:18 | REVISION #3, DATE 3/18/09, APPROVED*** | | | | | | | | | REVISED PLAN SHEET A2.0 STAMPED, INITIALED, AND DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2009-02-17 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2009-02-17 |
Time |
10:02 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2009-02-17 |
Time |
10:01 |
Sent To |
|
|
| Notes |
| 2009-02-17 10:02:39 | REVISION #2 DATED 1/30/09 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2008-12-05 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-12-05 |
Time |
12:51 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-12-05 |
Time |
12:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2008-10-30 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-10-30 |
Time |
10:57 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-10-30 |
Time |
10:57 |
Sent To |
|
|
| Notes |
| 2008-10-30 10:58:01 | ONLY ONE (1) SET OF PLANS STAMPED AT THIS TIME DUE TO | | | AVAILABILITY. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2009-09-15 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-09-15 |
Time |
11:34 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-09-15 |
Time |
11:34 |
Sent To |
M |
|
| Notes |
| 2009-09-15 11:34:59 | MECH REVISION SENT TO RR DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2009-07-29 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2009-07-29 |
Time |
09:32 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2009-07-29 |
Time |
09:32 |
Sent To |
|
|
| Notes |
| 2009-07-29 09:32:37 | IN MECH. BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2009-04-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-04-02 |
Time |
12:36 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-04-02 |
Time |
12:36 |
Sent To |
|
|
| Notes |
| 2009-04-02 12:38:41 | TO "B12" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2009-02-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-02-06 |
Time |
08:40 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-02-06 |
Time |
08:40 |
Sent To |
|
|
| Notes |
| 2009-02-06 08:43:02 | TO "BOB"#10 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-11-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-11-21 |
Time |
16:44 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-11-21 |
Time |
16:44 |
Sent To |
|
|
| Notes |
| 2008-11-25 16:54:45 | TO "BOB"#7 | | 2008-11-21 16:44:54 | WAITING FOR "BOB" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-11-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-10-30 |
Time |
16:43 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-10-22 |
Time |
10:02 |
Sent To |
|
|
| Notes |
| 2008-10-22 10:02:51 | TO "BOB"#13 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
N |
Date |
2009-09-23 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-09-23 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-09-15 |
Time |
11:41 |
Sent To |
|
|
| Notes |
| 2009-09-23 14:02:58 | REVISION WITHDRAWN BY CONTRACTOR PER CONVERSATION WITH | | | BOB LOUCKS, MECHANICAL ENGINEER. PLANS WILL NOT BE | | | PICKED UP AND WILL BE DISCARDED. MECHANICAL WORK TO BE | | | COMPLETED PER CURRENT PERMIT RECORD SET OF PLANS. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
F |
Date |
2009-08-06 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-08-06 |
Time |
15:11 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-08-06 |
Time |
15:04 |
Sent To |
E |
|
| Notes |
| 2009-08-06 15:07:30 | REVISED M1 AND M2 DENIED | | | | | | THIS REVISION HAS ELIMINATED TTHE DUCT SMOKE DETECTOR | | | AS REQUIRED PER FBC-M 606.2.1. SUBMITTAL FORM CLAIMS | | | THAT THE DESIGN CAPACITY OF THE NEW RTU DOES NOT EXCEED | | | 2000 CFM. HOWEVER, THE REVISED FLOOR PLAN A TOTAL AIR | | | SUPPLY OF 2210 CFM. THE DUCT SMOKE DETECTOR SHALL NOT | | | BE ELIMINATED. THE DUCT SMOKE DETECTOR SHALL BE | | | INSTALLED AND CONNECTED TO THE BUILDING FIRE ALARM | | | SYSTEM IN ACCORDANCE WITH FBC-M 606.4. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2009-04-14 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-04-14 |
Time |
16:44 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-04-14 |
Time |
16:44 |
Sent To |
PC |
|
| Notes |
| 2009-04-14 16:44:54 | REVISED M-1, CHANGE FROM CEILING TO SIDEWALL DIFFUSERS |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2009-02-15 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-02-15 |
Time |
11:55 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-02-15 |
Time |
11:54 |
Sent To |
|
|
| Notes |
| 2009-02-15 11:55:27 | REVISED M2 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2008-12-06 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-12-06 |
Time |
16:44 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-12-06 |
Time |
16:44 |
Sent To |
E |
|
| Notes |
| 2008-12-06 16:44:39 | PREVIOUS REVIEW PASSED, BUT MECH PAGES WERE CHANGED. | | | NEW PAGES REVIEWED AND STAMPED. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2008-10-28 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-10-28 |
Time |
14:50 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2008-10-28 |
Time |
14:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2009-02-17 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-02-17 |
Time |
17:00 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-02-17 |
Time |
17:00 |
Sent To |
|
|
| Notes |
| 2009-02-17 17:01:19 | REVISION OK -- SHT P1. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2008-12-04 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-12-04 |
Time |
08:53 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-12-04 |
Time |
08:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2008-10-29 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-10-29 |
Time |
13:29 |
Rev Time |
1.15 |
| Received By |
mperson |
Date |
2008-10-29 |
Time |
13:29 |
Sent To |
|
|
| Notes |
| 2008-10-29 14:29:01 | PLUMBING PLAN REVIEW: | | | DENIED: | | | | | | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | | PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE. | | | | | | 1. SHEET A1.0 INDICATES A PROPOSED HI/LO DRINKING | | | FOUNTAIN. PLEASE PROVIDE THE FOLLOWING INFORMATION | | | COMPLIANT WITH THE FBC-2004 CHAPTER 11, FLORIDA | | | ACCESSIBILITY CODE SECTIONS FOR THE DRINKING FOUNTAIN. | | | | | | **SECTION 11-4.15 DRINKING FOUNTAINS AND WATER COOLERS | | | (ELEVATION DETAIL REQUIRED WITH THE FOLLOWING | | | INFORMATION) | | | | | | SECTION 11-4.15.2 SPOUT HEIGHT. SPOUT HEIGHT 36" TO | | | OUTLET MAXIMUM. | | | | | | SECTION 11-4.15.3 SPOUT LOCATION. FRONT OF UNIT, WATER | | | FLOW IN TRAJECTORY THAT IS PARALLEL OR NEARLY PARALLEL | | | TO FRONT OF THE UNIT, WATER FLOW MINIMUM OF 4" HIGH. ON | | | AN ACCESSIBLE OVAL OR ROUND BOWL FLOW OF WATER IS | | | WITHIN 3" OF THE FRONT OF FOUNTAIN. | | | | | | SECTION 11-4.15.4 CONTROLS. SHALL BE FRONT MOUNTED OR | | | SIDE MOUNTED NEAR FRONT EDGE. | | | | | | SECTION 11-4.15.5 CLEARANCES. KNEE 27" HIGH, & 30" X | | | 48" FLOOR SPACE. | | | | | | SECTION 11-4.1.3(10)(A) WHERE ONLY ONE DRINKING | | | FOUNTAIN IS PROVIDED ON A FLOOR, THERE SHALL BE A | | | DRINKING FOUNTAIN WHICH IS ACCESSIBLE TO INDIVIDUALS | | | WHO USE WHEELCHAIRS IN ACCORDANCE WITH SECTION 11-4.15 | | | AND ONE ACCESSIBLE TO THOSE WHO HAVE DIFFICULTY BENDING | | | OR STOOPING.(THIS CAN BE ACCOMMODATED BY THE USE OF A | | | HI-LO FOUNTAIN OR BY SUCH OTHER MEANS AS WOULD ACHIEVE | | | THE REQUIRED ACCESSIBILITY FOR EACH GROUP ON EACH | | | FLOOR). | | | | | | 2. SHEET A1.0 INDICATES A SINK IN THE BREAK ROOM. | | | PLEASE PROVIDE THE FOLLOWING INFORMATION COMPLIANT WITH | | | THE FBC-2004 CHAPTER 11, FLORIDA ACCESSIBILITY CODE | | | SECTIONS FOR THE SINK. | | | | | | **SECTION 11-4.24 SINKS (ELEVATION DETAIL REQUIRED WITH | | | THE FOLLOWING INFORMATION) | | | | | | SECTION 11-4.24.2 HEIGHT. MAXIMUM 34" A.F.F. TO RIM OR | | | COUNTER. | | | | | | SECTION 11-4.24.3 KNEE CLEARANCE. MINIMUM 27" HIGH, 30" | | | WIDE, AND 19" DEEP. | | | | | | SECTION 11-4.24.4 DEPTH. MAXIMUM 6-1/2" DEEP. | | | | | | SECTION 11-4.24.5 CLEAR FLOOR SPACE. 30" X 48" AND | | | CLEAR FLOOR SPACE SHALL EXTEND A MAXIMUM OF 19" | | | UNDERNEATH THE SINK. | | | | | | SECTION 11-4.24.6 EXPOSED PIPES AND SURFACES. INSULATE | | | TO PROTECT AGAINST CONTACT. | | | | | | SECTION 11-4.24.7 FAUCETS. LEVER-OPERATED, PUSH-TYPE, | | | OR ELECTRONICALLY CONTROLLED ARE ACCEPTABLE DESIGNS. | | | | | | 3. SHEET A1.0 KEY NOTES (11): PLEASE ADD THE FOLLOWING | | | TO THIS KEY NOTE."PER FBC-2004 PLUMBING, SECTION 704.5 | | | DEAD ENDS: IN THE REMOVAL OF ANY PART OF A DRAINAGE | | | SYSTEM, DEAD ENDS SHALL BE PROHIBITED. A PLUMBING | | | PERMIT IS REQUIRED AND AN INSPECTION IS REQUIRED OF | | | PLUMBING DEMO WORK PRIOR TO COVERING DEMO WORK WITH | | | FINNISH WALLS, CIELINGS, OR POURED CONCRETE SLABS". | | | | | | 4. SHEET A3.0 ENLARGED TOILET ROOM PLAN AND ELEVATIONS: | | | PLEASE PROVIDE THE FOLLOWING REQUIRED INFORMATION | | | COMPLIANT WITH THE FBC-2004 CHAPTER 11, FLORIDA | | | ACCESSIBILITY CODE SECTIONS FOR THE FOLLOWING PLUMBING | | | FIXTURES. | | | | | | A} WATER CLOSETS SECTION 11-4.16.5 FLUSH CONTROLS. | | | MOUNTED ON WIDE SIDE MAX. 44" HIGH. | | | | | | B} LAVATORIES SECTION 11-4.19.5 FAUCETS. | | | LEVER-OPERATED, PUSH-TYPE AND ELECTRONICALLY CONTROLLED | | | ARE EXAMPLES. | | | | | | 5. SHEET P2 PLUMBING SPECIFICATIONS (8): PLEASE KNOW | | | THAT AIR CHAMBERS ARE NOT APPROVED BY THE FBC-2004 | | | PLUMBING CODE SECTION 604.9 WATER HAMMER AS A MEANS OF | | | CONTROLLING WATER HAMMER. PLEASE DELETE THE FOLLOWING | | | "ALL OTHER FIXTURES & SUPPLIES TO HAVE AIR CHAMBERS" ON | | | THIS NOTE FOR THE RESUBMITTAL. | | | | | | ********IMPORTANT INFORMATION******** | | | WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE | | | OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW | | | PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | END OF COMMENTS: | | | | | | *IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | PHONE= (561) 805-6730 | | | FAX= (561) 805-6731 | | | E-MAIL= [email protected] |
|
|