Plan Review Details - Permit 08100428
Plan Review Stops For Permit 08100428
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2009-04-07 Cont ID  
Sent By mjacobs Date 2009-04-07 Time 16:22 Rev Time 0.00
Received By mjacobs Date 2009-04-07 Time 16:22 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2009-02-12 Cont ID  
Sent By mjacobs Date 2009-02-12 Time 08:31 Rev Time 0.00
Received By mjacobs Date 2009-02-12 Time 08:31 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2008-12-02 Cont ID  
Sent By mjacobs Date 2008-12-02 Time 09:47 Rev Time 0.00
Received By mjacobs Date 2008-12-02 Time 09:47 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-10-28 Cont ID  
Sent By mjacobs Date 2008-10-28 Time 12:33 Rev Time 0.00
Received By mjacobs Date 2008-10-28 Time 12:33 Sent To  
Notes
2008-10-28 12:33:51BUILDING PLAN REVIEW
 PERMIT: 08100428
 ADD: 1525 N. FLAGLER DR. #100
 CONT: MORGAN CONTRACTING GROUP INC.
 TEL: (561)330-9600
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 10-28-08
 REVIEW: 1ST
 ACTION: DENIED
  
 1) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE & REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 2) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) AFTER
 JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC
 BUILDING WITH THE 2007 SUPPLEMENTS. THIS INFORMATION
 SHALL BE INDICATED ON THE PLANS.
  
 3) FBC 1210.2 WALLS WITHIN 2 FEET OF URINALS AND WATER
 CLOSETS SHALL HAVE A SMOOTH, HARD, NONABSORBENT
 SURFACE, TO A HEIGHT OF 4 FEET ABOVE THE FLOOR. NOTE:
 PAINT ON DRYWALL IS NOT CONSIDERED A HARD SURFACE.
  
 4) FBC 11-7.1(2) (I) A PORTION OF THE MAIN COUNTER
 SHALL HAVE A MINIMUM LENGTH OF 36 INCHES AND A MAXIMUM
 HEIGHT OF 36 INCHES. SHEET A3.1 #3 SHOWS THE RECEPTION
 DESK HEIGHT AT 3?- 6?.
  
 5) SHEET A1.0 DOOR #3 CLEARANCE SHALL MEET THE
 REQUIREMENTS OF 11-4.13.6 MANEUVERING CLEARENCES AT
 DOORS. MINIMUM MANEUVERING CLEARANCES AT DOORS THAT ARE
 NOT AUTOMATIC OR POWER-ASSISTED SHALL BE AS SHOWN IN
 FIG. 25. THE FLOOR OR GROUND AREA WITHIN THE REQUIRED
 CLEARANCES SHALL BE CLEAR & LEVEL. NOTE: 18? MINIMUM.
  
  
  
 6) (2004 FBC) 106.1.1 INFORMATION ON CONSTRUCTION
 DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL BE OF
 SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE &
 EXTENT OF THE WORK PROPOSED & SHOW IN DETAIL THAT IT
 WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, AND RULES AND REGULATIONS AS
 DETERMINED BY THE BUILDING OFFICIAL. THE PLANS NEED TO
 CLEARLY SHOW THE EXISTING WALLS AND THE NEW WALLS.
 PROVIDE A WALL LEGEND TO SHOW THIS ASPECT OF THE PLANS.
  
 7) ROOM 108 ON SHEET A1.0 WHERE THE DOOR IS REMOVED, IS
 THAT AN EXTERIOR WALL OR A PARTITION WALL WHICH NEEDS A
 FIRE RATING? IF THAT IS A PARTITION WALL, STATE THE UL
 NUMBER FOR THE NEW WALL. THERE IS NO WALL TYPE
 INDICATED.
  
 8) SHOW THE FOLLOWING INFORMATION FOR THE BREAK ROOM
 SINK ON THE PLANS. FBC 11-4.24.2. SINKS SHALL BE
 MOUNTED WITH THE COUNTER OR RIM NO HIGHER THAN 34"
 ABOVE THE FINISH FLOOR. 11-4.24.3 KNEE CLEARANCE THAT
 IS AT LEAST 27" HIGH 30" WIDE, AND 19" DEEP SHALL BE
 PROVIDED UNDERNEATH SINKS. 11-4.24.5 CLEAR FLOOR SPACE.
 A CLEAR FLOOR SPACE AT LEAST 30 INCHES BY 48 INCHES
 COMPLYING WITH SECTION 11-4.2.4 SHALL BE PROVIDED IN
 FRONT OF A SINK TO ALLOW FORWARD APPROACH. THE CLEAR
 FLOOR SPACE SHALL BE ON AN ACCESSIBLE ROUTE AND SHALL
 EXTEND A MAXIMUM OF 19 INCHES UNDERNEATH THE SINK.
  
 9) SHEET A1.0 ACCESSIBLE TOILET SHOWS TWO DIFFERENT
 TYPES OF WALL SYMBOLS IN BACK OF THE WATER CLOSET. WILL
 THERE BE A TYPE P-1 AND A TYPE P-2 WALL CONSTRUCTED IN
 THIS AREA? STATE HOW THE TOP AND BOTTOM TRACK WILL BE
 FASTENED TO THE STRUCTURE. CLARIFY.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 (561)805-6726
 [email protected]
  
  
  
  

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2009-08-14 Cont ID  
Sent By btrobaug Date 2009-08-14 Time 11:45 Rev Time 0.00
Received By btrobaug Date 2009-08-14 Time 11:18 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2009-02-10 Cont ID  
Sent By btrobaug Date 2009-02-10 Time 12:20 Rev Time 0.00
Received By btrobaug Date 2009-02-10 Time 11:14 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2008-12-08 Cont ID  
Sent By btrobaug Date 2008-12-08 Time 08:28 Rev Time 0.00
Received By btrobaug Date 2008-12-04 Time 13:18 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2008-10-24 Cont ID  
Sent By btrobaug Date 2008-10-24 Time 15:23 Rev Time 0.00
Received By btrobaug Date 2008-10-24 Time 14:48 Sent To  
Notes
2008-10-24 15:15:39 
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES:
  
 THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2005
 NEC, NFPA-72 2002, NFPA-101 2003, 2004 FBC AS AMENDED,
 CHAPTER 1.AND FOUND NONCOMPLIANT WITH THE FOLLOWING:
  
 1} THIS PROJECT MUST COMPLY WITH CHAPTER 13 FBC. SEE
 13-415.1ABC.1.1FOR TIME CLOCK REQUIREMENTS AND FOR
 LIGHTING DENSITIES. ALL THAT IS REQUIRED FOR THE
 ELECTRICAL REVIEW IS THE BASIC PRESCRIPTIVE
 REQUIREMENTS. SEE 13-415.2.ABC.1 PERFORMANCE
 CALCULATION PROCEDURES, GENERAL.
 THE INTERIOR LIGHTING POWER ALLOWANCE FOR A BUILDING OR
 A SEPARATELY METERED OR PERMITTED PORTION OF A BUILDING
 SHALL BE DETERMINED BY EITHER THE BUILDING AREA METHOD
 DESCRIBED IN SECTION 415.2.C.1 OR THE SPACE-BY-SPACE
 METHOD DESCRIBED IN SECTION 415.2.B.1. THE INSTALLED
 INTERIOR LIGHTING POWER IDENTIFIED IN ACCORDANCE WITH
 SECTION 415.2.ABC.1.1 SHALL NOT EXCEED THE INTERIOR
 LIGHTING POWER ALLOWANCE DEVELOPED IN ACCORDANCE WITH
 SECTION 415.2.C.1 OR 415.2.B.1. THIS CAN BE
 DEMONSTRATED ON THE PLANS INDICATING THE WATTAGES OF
 THE LUMINAIRES CHOSEN FOR THE PROJECT CONFORM TO THE
 DENSITY REQUIREMENTS. INDICATE WATTAGES ON THE FIXTURE
 SCHEDULE TO CORRELATE WITH THE ONES IN THE
 CALCULATIONS.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status P Date 2009-04-09 Cont ID  
Sent By mawillia Date 2009-04-09 Time 14:51 Rev Time 0.00
Received By mawillia Date 2009-04-09 Time 14:43 Sent To  
Notes
2009-04-09 14:53:18REVISION #3, DATE 3/18/09, APPROVED***
  
  
 REVISED PLAN SHEET A2.0 STAMPED, INITIALED, AND DATED.

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2009-02-17 Cont ID  
Sent By mwennerg Date 2009-02-17 Time 10:02 Rev Time 0.00
Received By mwennerg Date 2009-02-17 Time 10:01 Sent To  
Notes
2009-02-17 10:02:39REVISION #2 DATED 1/30/09

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2008-12-05 Cont ID  
Sent By mwennerg Date 2008-12-05 Time 12:51 Rev Time 0.00
Received By mwennerg Date 2008-12-05 Time 12:51 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2008-10-30 Cont ID  
Sent By mwennerg Date 2008-10-30 Time 10:57 Rev Time 0.00
Received By mwennerg Date 2008-10-30 Time 10:57 Sent To  
Notes
2008-10-30 10:58:01ONLY ONE (1) SET OF PLANS STAMPED AT THIS TIME DUE TO
 AVAILABILITY.

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2009-09-15 Cont ID  
Sent By rregueir Date 2009-09-15 Time 11:34 Rev Time 0.00
Received By rregueir Date 2009-09-15 Time 11:34 Sent To M
Notes
2009-09-15 11:34:59MECH REVISION SENT TO RR DESK.

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2009-07-29 Cont ID  
Sent By lmartine Date 2009-07-29 Time 09:32 Rev Time 0.00
Received By lmartine Date 2009-07-29 Time 09:32 Sent To  
Notes
2009-07-29 09:32:37IN MECH. BOX

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2009-04-02 Cont ID  
Sent By adarroug Date 2009-04-02 Time 12:36 Rev Time 0.00
Received By adarroug Date 2009-04-02 Time 12:36 Sent To  
Notes
2009-04-02 12:38:41TO "B12"

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2009-02-06 Cont ID  
Sent By adarroug Date 2009-02-06 Time 08:40 Rev Time 0.00
Received By adarroug Date 2009-02-06 Time 08:40 Sent To  
Notes
2009-02-06 08:43:02TO "BOB"#10

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-11-21 Cont ID  
Sent By adarroug Date 2008-11-21 Time 16:44 Rev Time 0.00
Received By adarroug Date 2008-11-21 Time 16:44 Sent To  
Notes
2008-11-25 16:54:45TO "BOB"#7
2008-11-21 16:44:54WAITING FOR "BOB"

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-11-21 Cont ID  
Sent By adarroug Date 2008-10-30 Time 16:43 Rev Time 0.00
Received By adarroug Date 2008-10-22 Time 10:02 Sent To  
Notes
2008-10-22 10:02:51TO "BOB"#13

Review Stop M MECHANICAL (A/C)
Rev No 6 Status N Date 2009-09-23 Cont ID  
Sent By rregueir Date 2009-09-23 Time 14:01 Rev Time 0.00
Received By rregueir Date 2009-09-15 Time 11:41 Sent To  
Notes
2009-09-23 14:02:58REVISION WITHDRAWN BY CONTRACTOR PER CONVERSATION WITH
 BOB LOUCKS, MECHANICAL ENGINEER. PLANS WILL NOT BE
 PICKED UP AND WILL BE DISCARDED. MECHANICAL WORK TO BE
 COMPLETED PER CURRENT PERMIT RECORD SET OF PLANS.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT:
 RONALD J. REGUEIRO
 561.805.6719
 [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 5 Status F Date 2009-08-06 Cont ID  
Sent By rregueir Date 2009-08-06 Time 15:11 Rev Time 0.00
Received By rregueir Date 2009-08-06 Time 15:04 Sent To E
Notes
2009-08-06 15:07:30REVISED M1 AND M2 DENIED
  
 THIS REVISION HAS ELIMINATED TTHE DUCT SMOKE DETECTOR
 AS REQUIRED PER FBC-M 606.2.1. SUBMITTAL FORM CLAIMS
 THAT THE DESIGN CAPACITY OF THE NEW RTU DOES NOT EXCEED
 2000 CFM. HOWEVER, THE REVISED FLOOR PLAN A TOTAL AIR
 SUPPLY OF 2210 CFM. THE DUCT SMOKE DETECTOR SHALL NOT
 BE ELIMINATED. THE DUCT SMOKE DETECTOR SHALL BE
 INSTALLED AND CONNECTED TO THE BUILDING FIRE ALARM
 SYSTEM IN ACCORDANCE WITH FBC-M 606.4.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT:
 RONALD J. REGUEIRO
 561.805.6719
 [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2009-04-14 Cont ID  
Sent By rregueir Date 2009-04-14 Time 16:44 Rev Time 0.00
Received By rregueir Date 2009-04-14 Time 16:44 Sent To PC
Notes
2009-04-14 16:44:54REVISED M-1, CHANGE FROM CEILING TO SIDEWALL DIFFUSERS

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2009-02-15 Cont ID  
Sent By rregueir Date 2009-02-15 Time 11:55 Rev Time 0.00
Received By rregueir Date 2009-02-15 Time 11:54 Sent To  
Notes
2009-02-15 11:55:27REVISED M2

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2008-12-06 Cont ID  
Sent By rregueir Date 2008-12-06 Time 16:44 Rev Time 0.00
Received By rregueir Date 2008-12-06 Time 16:44 Sent To E
Notes
2008-12-06 16:44:39PREVIOUS REVIEW PASSED, BUT MECH PAGES WERE CHANGED.
 NEW PAGES REVIEWED AND STAMPED.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2008-10-28 Cont ID  
Sent By tgordon Date 2008-10-28 Time 14:50 Rev Time 0.45
Received By tgordon Date 2008-10-28 Time 14:50 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2009-02-17 Cont ID  
Sent By kstevens Date 2009-02-17 Time 17:00 Rev Time 0.00
Received By kstevens Date 2009-02-17 Time 17:00 Sent To  
Notes
2009-02-17 17:01:19REVISION OK -- SHT P1.

Review Stop P PLUMBING
Rev No 2 Status P Date 2008-12-04 Cont ID  
Sent By kstevens Date 2008-12-04 Time 08:53 Rev Time 0.00
Received By kstevens Date 2008-12-04 Time 08:53 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2008-10-29 Cont ID  
Sent By mperson Date 2008-10-29 Time 13:29 Rev Time 1.15
Received By mperson Date 2008-10-29 Time 13:29 Sent To  
Notes
2008-10-29 14:29:01PLUMBING PLAN REVIEW:
 DENIED:
  
 PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH
 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO
 CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE
 (F.A.C.), AND FLORIDA STATUTES (F.S.).
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE.
  
 1. SHEET A1.0 INDICATES A PROPOSED HI/LO DRINKING
 FOUNTAIN. PLEASE PROVIDE THE FOLLOWING INFORMATION
 COMPLIANT WITH THE FBC-2004 CHAPTER 11, FLORIDA
 ACCESSIBILITY CODE SECTIONS FOR THE DRINKING FOUNTAIN.
  
 **SECTION 11-4.15 DRINKING FOUNTAINS AND WATER COOLERS
 (ELEVATION DETAIL REQUIRED WITH THE FOLLOWING
 INFORMATION)
  
 SECTION 11-4.15.2 SPOUT HEIGHT. SPOUT HEIGHT 36" TO
 OUTLET MAXIMUM.
  
 SECTION 11-4.15.3 SPOUT LOCATION. FRONT OF UNIT, WATER
 FLOW IN TRAJECTORY THAT IS PARALLEL OR NEARLY PARALLEL
 TO FRONT OF THE UNIT, WATER FLOW MINIMUM OF 4" HIGH. ON
 AN ACCESSIBLE OVAL OR ROUND BOWL FLOW OF WATER IS
 WITHIN 3" OF THE FRONT OF FOUNTAIN.
  
 SECTION 11-4.15.4 CONTROLS. SHALL BE FRONT MOUNTED OR
 SIDE MOUNTED NEAR FRONT EDGE.
  
 SECTION 11-4.15.5 CLEARANCES. KNEE 27" HIGH, & 30" X
 48" FLOOR SPACE.
  
 SECTION 11-4.1.3(10)(A) WHERE ONLY ONE DRINKING
 FOUNTAIN IS PROVIDED ON A FLOOR, THERE SHALL BE A
 DRINKING FOUNTAIN WHICH IS ACCESSIBLE TO INDIVIDUALS
 WHO USE WHEELCHAIRS IN ACCORDANCE WITH SECTION 11-4.15
 AND ONE ACCESSIBLE TO THOSE WHO HAVE DIFFICULTY BENDING
 OR STOOPING.(THIS CAN BE ACCOMMODATED BY THE USE OF A
 HI-LO FOUNTAIN OR BY SUCH OTHER MEANS AS WOULD ACHIEVE
 THE REQUIRED ACCESSIBILITY FOR EACH GROUP ON EACH
 FLOOR).
  
 2. SHEET A1.0 INDICATES A SINK IN THE BREAK ROOM.
 PLEASE PROVIDE THE FOLLOWING INFORMATION COMPLIANT WITH
 THE FBC-2004 CHAPTER 11, FLORIDA ACCESSIBILITY CODE
 SECTIONS FOR THE SINK.
  
 **SECTION 11-4.24 SINKS (ELEVATION DETAIL REQUIRED WITH
 THE FOLLOWING INFORMATION)
  
 SECTION 11-4.24.2 HEIGHT. MAXIMUM 34" A.F.F. TO RIM OR
 COUNTER.
  
 SECTION 11-4.24.3 KNEE CLEARANCE. MINIMUM 27" HIGH, 30"
 WIDE, AND 19" DEEP.
  
 SECTION 11-4.24.4 DEPTH. MAXIMUM 6-1/2" DEEP.
  
 SECTION 11-4.24.5 CLEAR FLOOR SPACE. 30" X 48" AND
 CLEAR FLOOR SPACE SHALL EXTEND A MAXIMUM OF 19"
 UNDERNEATH THE SINK.
  
 SECTION 11-4.24.6 EXPOSED PIPES AND SURFACES. INSULATE
 TO PROTECT AGAINST CONTACT.
  
 SECTION 11-4.24.7 FAUCETS. LEVER-OPERATED, PUSH-TYPE,
 OR ELECTRONICALLY CONTROLLED ARE ACCEPTABLE DESIGNS.
  
 3. SHEET A1.0 KEY NOTES (11): PLEASE ADD THE FOLLOWING
 TO THIS KEY NOTE."PER FBC-2004 PLUMBING, SECTION 704.5
 DEAD ENDS: IN THE REMOVAL OF ANY PART OF A DRAINAGE
 SYSTEM, DEAD ENDS SHALL BE PROHIBITED. A PLUMBING
 PERMIT IS REQUIRED AND AN INSPECTION IS REQUIRED OF
 PLUMBING DEMO WORK PRIOR TO COVERING DEMO WORK WITH
 FINNISH WALLS, CIELINGS, OR POURED CONCRETE SLABS".
  
 4. SHEET A3.0 ENLARGED TOILET ROOM PLAN AND ELEVATIONS:
 PLEASE PROVIDE THE FOLLOWING REQUIRED INFORMATION
 COMPLIANT WITH THE FBC-2004 CHAPTER 11, FLORIDA
 ACCESSIBILITY CODE SECTIONS FOR THE FOLLOWING PLUMBING
 FIXTURES.
  
 A} WATER CLOSETS SECTION 11-4.16.5 FLUSH CONTROLS.
 MOUNTED ON WIDE SIDE MAX. 44" HIGH.
  
 B} LAVATORIES SECTION 11-4.19.5 FAUCETS.
 LEVER-OPERATED, PUSH-TYPE AND ELECTRONICALLY CONTROLLED
 ARE EXAMPLES.
  
 5. SHEET P2 PLUMBING SPECIFICATIONS (8): PLEASE KNOW
 THAT AIR CHAMBERS ARE NOT APPROVED BY THE FBC-2004
 PLUMBING CODE SECTION 604.9 WATER HAMMER AS A MEANS OF
 CONTROLLING WATER HAMMER. PLEASE DELETE THE FOLLOWING
 "ALL OTHER FIXTURES & SUPPLIES TO HAVE AIR CHAMBERS" ON
 THIS NOTE FOR THE RESUBMITTAL.
  
 ********IMPORTANT INFORMATION********
 WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE
 OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW
 PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 END OF COMMENTS:
  
 *IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 PHONE= (561) 805-6730
 FAX= (561) 805-6731
 E-MAIL= [email protected]


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved