Plan Review Details - Permit 08100364
Plan Review Stops For Permit 08100364
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2009-07-17 Cont ID  
Sent By rmcdouga Date 2009-07-17 Time 13:29 Rev Time 0.00
Received By rmcdouga Date 2009-07-17 Time 13:29 Sent To  
Notes
2009-07-17 13:31:15SUBMITTED PRODUCT APPROVAL FOR OUTSWING DOOR AS
 REQUESTED IN PROVISO.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2008-12-02 Cont ID  
Sent By rmcdouga Date 2008-12-02 Time 07:46 Rev Time 0.00
Received By rmcdouga Date 2008-12-02 Time 07:46 Sent To P
Notes
2008-12-02 08:04:27BUILDING PROVISO
  
 SUBMIT TWO COPIES OF PRODUCT APPROVALS FOR THE 2-8 X
 6-8 OUTSWING DOOR FOR APPROVAL PRIOR TO INSTALLING.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-10-27 Cont ID  
Sent By rmcdouga Date 2008-10-27 Time 13:53 Rev Time 0.00
Received By rmcdouga Date 2008-10-27 Time 13:53 Sent To P
Notes
2008-10-27 14:28:522004 FBC W/2007 REVISIONS
 CONSTRUCT DETACHED GARAGE
  
 DENIED BY BUILDING
  
 1) THE PRODUCT APPROVAL FOR THE JOHNS-MANVILLE MODIFIED
 ROOFING SYSTEM THAT WAS SUBMITTED IS FOR THE 2007
 FLORIDA BUILDING CODE. THE CURRENT CODE IS THE 2004
 FBC. PLEASE SUBMIT TWO COPIES OF THE PRODUCT APPROVALS
 FOR THE 2004 FBC. FAC RULE 9B-72. NOTE: SPECIFY WHICH
 ONE OF THE APPROVED ASSEMBLIES AND FASTENING OPTION
 WILL BE USED LISTED IN THE PRODUCT APPROVAL WILL BE
 INSTALLED. IF THE DESIGN PRESSURE IS LESS THAN -89 PSF,
 THEN PROVIDE RAS 117 CALCULATIONS FOR THE ENHANCED
 FASTENING AT THE PERIMETER AND CORNER ROOF AREAS.
  
 2) THE PRODUCT APPROVAL FOR THE CLOPAY GARAGE DOOR IS
 NO LONGER CURRENT. SUBMIT TWO CURRENT STATE OR
 MIAMI-DADE PRODUCT APPROVALS FOR THE GARAGE DOOR AS
 REQUIRED BY FAC RULE 9B-72.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2009-05-27 Cont ID  
Sent By btrobaug Date 2009-05-27 Time 12:00 Rev Time 0.00
Received By btrobaug Date 2009-05-27 Time 11:58 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2008-12-01 Cont ID  
Sent By btrobaug Date 2008-12-01 Time 10:22 Rev Time 0.00
Received By btrobaug Date 2008-12-01 Time 10:12 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2008-10-27 Cont ID  
Sent By btrobaug Date 2008-10-27 Time 09:26 Rev Time 0.00
Received By btrobaug Date 2008-10-27 Time 07:11 Sent To M
Notes
2008-10-27 09:26:56 
  
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES:
  
 THE 2004 FLORIDA RESIDENTIAL BUILDING CODE, 2007
 REVISIONS, 2005 NEC, 2004 FBC AS AMENDED, CHAPTER 1.AND
 FOUND NONCOMPLIANT WITH THE FOLLOWING:
  
 1} 225.31 DISCONNECTING MEANS
 MEANS SHALL BE PROVIDED FOR DISCONNECTING ALL
 UNGROUNDED CONDUCTORS THAT SUPPLY OR PASS THROUGH THE
 BUILDING OR STRUCTURE.
 225.32 LOCATION
 THE DISCONNECTING MEANS SHALL BE INSTALLED EITHER
 INSIDE OR OUTSIDE OF THE BUILDING OR STRUCTURE SERVED
 OR WHERE THE CONDUCTORS PASS THROUGH THE BUILDING OR
 STRUCTURE. THE DISCONNECTING MEANS SHALL BE AT A
 READILY ACCESSIBLE LOCATION NEAREST THE POINT OF
 ENTRANCE OF THE CONDUCTORS. FOR THE PURPOSES OF THIS
 SECTION, THE REQUIREMENTS IN 230.6 SHALL BE UTILIZED.
  
 2} 250.32 BUILDINGS OR STRUCTURES SUPPLIED BY FEEDER(S)
 OR BRANCH CIRCUIT(S)
 (A) GROUNDING ELECTRODE BUILDING(S) OR STRUCTURE(S)
 SUPPLIED BY FEEDER(S) OR BRANCH CIRCUIT(S) SHALL HAVE A
 GROUNDING ELECTRODE OR GROUNDING ELECTRODE SYSTEM
 INSTALLED IN ACCORDANCE WITH 250.50. THE GROUNDING
 ELECTRODE CONDUCTOR(S) SHALL BE CONNECTED IN ACCORDANCE
 WITH 250.32(B) OR (C). WHERE THERE IS NO EXISTING
 GROUNDING ELECTRODE, THE GROUNDING ELECTRODE(S)
 REQUIRED IN 250.50 SHALL BE INSTALLED.
  
 INDICATE COMPLIANCE WITH THESE ARTICLES BY PROVIDING A
 RISER DIAGRAM
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
  

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2009-07-14 Cont ID  
Sent By dpalmer Date 2009-07-14 Time 13:55 Rev Time 0.00
Received By dpalmer Date 2009-07-14 Time 13:55 Sent To B
Notes
2009-07-14 13:55:49TO RMCD

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2009-05-22 Cont ID  
Sent By dpalmer Date 2009-05-22 Time 15:03 Rev Time 0.00
Received By dpalmer Date 2009-05-22 Time 15:03 Sent To E
Notes
2009-05-22 15:03:53TO BT

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2008-11-18 Cont ID  
Sent By adarroug Date 2008-11-18 Time 13:52 Rev Time 0.00
Received By adarroug Date 2008-11-18 Time 13:52 Sent To Z
Notes
2008-11-18 13:52:39TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-10-24 Cont ID  
Sent By adarroug Date 2008-10-24 Time 16:09 Rev Time 0.00
Received By adarroug Date 2008-10-24 Time 16:09 Sent To E
Notes
2008-10-24 16:09:38TO "SFR" "E"

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-10-28 Cont ID  
Sent By mperson Date 2008-10-28 Time 14:07 Rev Time 0.00
Received By mperson Date 2008-10-17 Time 11:21 Sent To PC
Notes
2008-10-17 11:21:35TO "SFR" "Z"

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2008-10-27 Cont ID  
Sent By rmcdouga Date 2008-10-27 Time 14:29 Rev Time 0.00
Received By rmcdouga Date 2008-10-27 Time 14:29 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2008-12-17 Cont ID  
Sent By rmcdouga Date 2008-12-17 Time 13:39 Rev Time 0.00
Received By rmcdouga Date 2008-12-17 Time 13:39 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2008-10-28 Cont ID  
Sent By mperson Date 2008-10-28 Time 12:00 Rev Time 0.30
Received By mperson Date 2008-10-28 Time 11:55 Sent To I
Notes
2008-10-28 12:00:23PLUMBING PLAN REVIEW:
 DENIED:
  
 PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH
 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO
 CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE
 (F.A.C.), AND FLORIDA STATUTES (F.S.).
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE.
  
 1. SHEET A-1 INDICATES AN EXISTING WELL HEAD LOCATED
 INSIDE THE PROPOSE DETACHED GARAGE. PLEASE PROVIDE THE
 FOLLOWING INFORMATION OF THE EXISTING WELL HEAD ON THE
 RESUBMITTED PLANS PER THE FBC-2004 PLUMBING CODE
 SETIONS.
  
 A} PLEASE CLARIFY THE USE OF THE EXISTING WELL HEAD. IS
 THE EXISTING WELL HEAD FOR POTABLE WATER OR IRRIGATION.
 PLEASE CLEARLY INDICATE THIS ON THE RESUBMITTAL. PER
 FBC-2004 PLUMBING SECTION 601.1 SCOPE.
  
 B} PLEASE CLARIFY IF THERE IS ALSO AN EXISTING PUMP FOR
 THE EXISTING WELL HEAD AND IF THERE IS CLEARLY INDICATE
 ON THE RESUBMITTAL ITS LOCATION. PER FBC-2004 PLUMBING
 SECTION 601.1 SCOPE.
  
 C} PLEASE PROVIDE A DETAIL OF THE EXISTING WELL HEAD
 AND ANY RELATED PIPING AND PUMP. CLEARLY INDICATE ON
 THE DETAIL IF THE EXISTING WELL AND ANY RELATED PIPING
 AND PUMP ARE LOCATED ABOVE OR BELOW THE FINNISH FLOOR
 ELEVATION OF THE PROPOSED DETACHED GARAGE. PER FBC-2004
 PLUMBING SECTION 601.1 SCOPE.
  
 D} CLEARLY INDICATE THAT THE EXISTING WELL HEAD AND ANY
 RELATED PIPING AND PUMP WILL BE PROTECTED FROM PHYSICAL
 DAMAGE THAT MAY OCCUR FROM A VEHICLE (SUCH AS A
 BOLLARD). PLEASE PROVIDE A DETAIL OF HOW EXISTING WELL
 HEAD AND ANY RELATED PIPING AND PUMP WILL BE PROTECTED.
 PER FBC-2004 PLUMBING SECTION 305.9 PROTECTION OF
 COMPONENTS OF PLUMBING SYSTEMS.
  
 ********IMPORTANT INFORMATION********
 WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE
 OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW
 PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 END OF COMMENTS:
  
 *PLEASE CALL IF THERE ARE ANY QUESTIONS.
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 PHONE= (561) 805-6730
 FAX= (561) 805-6731
 E-MAIL= [email protected]

Review Stop Z ZONING
Rev No 2 Status P Date 2008-11-24 Cont ID  
Sent By mcruz Date 2008-11-24 Time 17:18 Rev Time 0.00
Received By mcruz Date 2008-11-24 Time 17:18 Sent To E
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2008-10-24 Cont ID  
Sent By mcruz Date 2008-10-24 Time 11:48 Rev Time 0.00
Received By mcruz Date 2008-10-24 Time 11:01 Sent To I
Notes
***NONE***