Plan Review Details - Permit 08100360
Plan Review Stops For Permit 08100360
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-10-20 Cont ID  
Sent By rmcdouga Date 2008-10-20 Time 16:50 Rev Time 0.00
Received By rmcdouga Date 2008-10-20 Time 16:50 Sent To  
Notes
2008-10-20 16:50:092004 FBC W/2007 REVISIONS
 REMODEL KITCHEN AND 3 BATHROOMS
  
 DENIED BY BUILDING
  
 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT WILL
 BE REQUIRED. FS 713
  
 2) THE BATHROOM PLAN THAT WAS SUBMITTED IS ILLEGIBLE.
 SUBMIT CLEAR LEGIBLE PLANS. FBC 106.1.3* CITY
 AMENDMENTS
  
 3) SUBMIT 2 COPIES OF FLOOR PLANS WITH DIMENSIONS FOR
 EACH OF THE ROOMS THAT ARE BEING REMODELED. SPECIFY THE
 SCOPE OF WORK THAT WILL BE DONE IN EACH ROOM. FBC
 106.1* CITY AMENDMENTS AND R307
  
 4) SPECIFY THE ADDRESS OF THE PROJECT ON EACH SHEET OF
 DRAWINGS. FBC 106.1.3* CITY AMENDMENTS
  
 5) SPECIFY THE NAME AND CONTACT INFORMATION FOR THE
 PERSON RESPONSIBLE FOR THE DRAWINGS ON EACH SHEET. FBC
 106.1.3* CITY AMENDMENTS
  
 6) SPECIFY THE 2004 FBC W/2007 REVISIONS ON THE PLANS,
 AS THIS IS THE APPLICABLE CODE EDITION.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2008-10-22 Cont ID  
Sent By btrobaug Date 2008-10-22 Time 12:57 Rev Time 0.00
Received By btrobaug Date 2008-10-22 Time 12:27 Sent To P
Notes
2008-10-22 12:57:05 
  
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES:
  
 THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2004
 RESIDENTIAL BUILDING CODE, 2005 NEC, 2004 FBC CHAPTER 1
 AS AMENDED AND FOUND NONCOMPLIANT WITH THE FOLLOWING:
  
 1} INDICATE EXISTING LOCATIONS OF KITCHEN RECEPTACLE
 SPACING. MUST COMPLY WITH 210.52(A), 210.52(C), AND
 210.8(A)(6) GFI.
  
 2} BATH CIRCUIT REQUIRED TO HAVE A 20 AMP RECEPTACLE
 PER 210.11(C) (3), LOCATED PER 210.52(D), AND BE GFI
 PROTECTED PER 210.8(A) (1).
  
 3} THE PERSON TAKING RESPONSIBILITY FOR THE DESIGN MUST
 PRINT AND SIGN THEIR NAME TO SAME, ALL SHEETS, PER
 106.1.3.FBC..
  
 4} THE INSTRUCTIONS FOR THE SCOPE OF WORK SUBMITTED ON
 THE LAST SHEET OF THE PLANS (NOT NUMBERED) ARE NOT
 CLEAR ENOUGH TO BE READ.
  
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-10-28 Cont ID  
Sent By tgordon Date 2008-10-28 Time 12:16 Rev Time 0.00
Received By tgordon Date 2008-10-17 Time 11:08 Sent To  
Notes
2008-10-17 11:10:34TO "SFR" "E"

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2008-10-28 Cont ID  
Sent By tgordon Date 2008-10-28 Time 12:16 Rev Time 0.20
Received By tgordon Date 2008-10-28 Time 12:16 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2008-10-28 Cont ID  
Sent By mperson Date 2008-10-28 Time 11:09 Rev Time 0.30
Received By mperson Date 2008-10-28 Time 11:09 Sent To M
Notes
2008-10-28 11:33:22PLUMBING PLAN REVIEW:
 DENIED:
  
 PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH
 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO
 CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE
 (F.A.C.), AND FLORIDA STATUTES (F.S.).
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE.
  
 1. MORE INFORMATION IS REQUIRED DUE TO THE FACT THAT
 THE PERMIT APPLICATION IS INDICATING KITCHEN AND MASTER
 BATH REMODEL. PLEASE PROVIDE THE FOLLOWING INFORMATION
 IF IT PERTAINS TO YOUR JOB.
  
 A} IF PLUMBING LAYOUT IS THE SAME AND THE PLUMBING
 FIXTURES ARE TO BE CHANGED, PLEASE INDICATE ON THE
 RESUBMITTED DRAWINGS. "EXACT FIXTURE CHANGEOUT ONLY"
 AND CLEARLY INDICATE WHAT FIXTURES ARE GOING TO BE
 CHANGED.
  
 B} IF THE NEW PROPOSED PLUMBING LAYOUT IS DIFFERENT
 FROM THE EXISTING PLEASE SUBMIT THE FOLLOWING ON
 SEPERATE DRAWINGS.
 A) EXISTING FLOOR PLAN LAYOUT.
 B) NEW PROPOSED FLOOR PLAN LAYOUT AND PLEASE FOLLOW
 WHAT IS REQUIRED IN COMMENT #2.
  
 2. PER FBC-2004 CHAPTER 1, (W.P.B. AS AMENDED) SECTION
 106.3.5.4 RESIDENTIAL (ONE AND TWO-FAMILY) (9)
 PLUMBING: PLEASE SUBMIT A PLUMBING SANITARY ISOMETRIC
 RISER DIAGRAM INDICATING ALL WASTE, VENTS, TRAPS AND
 SIZES WITH CLEANOUT LOCATIONS OF THE PROPOSED PLUMBING.
  
 3. NOTE: ALL PLANS, SPECIFICATIONS, AND ACCOMPANYING
 DATA BEING FILED FOR PUBLIC RECORD SHALL CONTAIN THE
 PRINTED NAME OF THE RESPONSIBLE PERSON WITH THE
 ORIGINAL SIGNATURE AND DATE ON SUCH INFORMATION. PER
 FBC-2004 CHAPTER 1, (W.P.B. AS AMENDED) SECTION
 *106.1.3 QUALITY OF BUILDING PLANS. THE BUILDING
 OFFICIAL MAY ESTABLISH THROUGH DEPARTMENTAL POLICY,
 STANDARDS FOR PLANS AND SPECIFICATIONS, IN ORDER TO
 PROVIDE CONFORMITY TO ITS RECORD RETENTION PROGRAM.
  
 4. NOTE: THE LAST PLAN SHEET IS HARD TO READ (NOT
 NUMBERED). PLEASE CLARIFY THIS SHEET AND THE SCOPE OF
 WORK WRITTEN ON THIS PLAN SHEET. PER FBC-2004 CHAPTER
 1, (W.P.B. AS AMENDED) SECTION 106.1.1 INFORMATION ON
 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL BE
 OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE
 AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT
 IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELAVENT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL.
  
 ********IMPORTANT INFORMATION********
 WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE
 OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW
 PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 END OF COMMENTS:
  
 *IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER