Plan Review Details - Permit 08100349
| Plan Review Stops For Permit 08100349 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2008-10-27 |
|
|
Cont ID |
|
| Sent By |
jnguyen |
Date |
2008-10-24 |
Time |
17:00 |
Rev Time |
0.00 |
| Received By |
jnguyen |
Date |
2008-10-24 |
Time |
13:00 |
Sent To |
|
|
| Notes |
| 2008-10-24 16:33:39 | I TALKED TO JOHN ENCK FROM PBC PAPA & HE SAID THAT THE | | | NEW CITY PCN# WILL LIKELY BE 74-42-43-28-16-002-0000. | | | HOWEVER, IT LIKELY WILL NOT BECOME OFFICIAL UNTIL SOME | | | TIME IN 2009. IN THE MEANTIME, I HAVE ISSUED A | | | TEMPORARY PCN# CALLED TEMP74424328160020000. PLEASE | | | ATTACH ALL FUTURE PERMITS TO THIS TEMPORARY PCN# | | | TEMP74424328160020000. | | 2008-10-15 14:48:13 | THIS ADDRESS IS BEING ANNEXED INTO THE CITY - NEED | | | CORRECT PCN# |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2010-03-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2010-03-24 |
Time |
15:12 |
Rev Time |
2.20 |
| Received By |
jwitmer |
Date |
2010-03-24 |
Time |
15:12 |
Sent To |
|
|
| Notes |
| 2010-03-24 15:13:52 | | | | ROOFING PRODUCT APPROVAL INFORMATION: | | | FIRESTONE BUILDING PRODUCTS: FIRESTONE ULTRAPLY TPO | | | SINGLE PLY ROOF SYSTEMS OVER WOOD DECKS | | | NOA: 07-0130.04 | | | PAGE # 5 | | | MEMBRANE TPYE: SINGLE PLY, TPO, REINFORCED | | | DECK TYPE: WOOD, INSULATED | | | SYSTEM TYPE:D | | | MAXIMUM DESIGN PRESSURE -60 PSF GENERAL LIMITATION# 7 | | | ENHANCED FASTENING BY ATLANTIC & CARIBBEAN ROOFING | | | CONSULTING, LLC | | | P1= -46.77 PSF | | | P2= -78.435 | | | P3= -118.049 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2010-01-13 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2010-01-13 |
Time |
08:27 |
Rev Time |
1.50 |
| Received By |
jwitmer |
Date |
2010-01-13 |
Time |
08:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2009-11-03 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-11-03 |
Time |
19:31 |
Rev Time |
2.75 |
| Received By |
jwitmer |
Date |
2009-10-27 |
Time |
07:00 |
Sent To |
|
|
| Notes |
| 2009-11-03 19:01:44 | MISSING FROM THE SECOND ROUND OF COMMENTS ARE 2 | | | ORIGINAL SIGNED AND SEALED GEOTECHNICAL REPORTS: | | | | | | 1802.2.1 QUESTIONABLE SOIL. WHERE THE SAFE-SUSTAINING | | | POWER OF THE SOIL IS IN DOUBT, OR WHERE A LOAD-BEARING | | | VALUE SUPERIOR TO THAT SPECIFIED IN THIS CODE IS | | | CLAIMED, THE BUILDING OFFICIAL SHALL REQUIRE THAT THE | | | NECESSARY INVESTIGATION BE MADE. SUCH INVESTIGATION | | | SHALL COMPLY WITH THE PROVISIONS OF SECTIONS 1802.4 | | | THROUGH 1802.6 . | | | | | | | | | | | | ROOFING PRODUCT APPROVAL INFORMATION: | | | FIRESTONE BUILDING PRODUCTS: FIRESTONE ULTRAPLY TPO | | | SINGLE PLY ROOF SYSTEMS OVER WOOD DECKS | | | NOA: 07-0130.04 | | | PAGE # 5 | | | MEMBRANE TPYE: SINGLE PLY, TPO, REINFORCED | | | DECK TYPE: WOOD, INSULATED | | | SYSTEM TYPE:D | | | MAXIMUM DESIGN PRESSURE -60 PSF GENERAL LIMITATION# 7 | | | ENHANCED FASTENING BY ATLANTIC & CARIBBEAN ROOFING | | | CONSULTING, LLC | | | P1= -46.77 PSF | | | P2= -78.435 | | | P3= -118.049 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2009-01-22 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-01-22 |
Time |
15:34 |
Rev Time |
3.33 |
| Received By |
jwitmer |
Date |
2009-01-22 |
Time |
15:34 |
Sent To |
|
|
| Notes |
| 2009-01-22 15:39:00 | BUILDING PLAN REVIEW | | | PERMIT: 08100349 | | | ADD: 8132 OKEECHOBEE BLVD | | | CONT: MAJOR WORKING DRAWING REVIEW/ ANDREA CARDO | | | TEL: (954)654-5828 | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | JAN 22/2009 | | | 2ND REVIEW | | | ACTION: DENIED | | | | | | 1A) INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE | | | INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | 1B) INFORMATIONAL: PLEASE SUBMIT 2 OF ALL SURVEYS, | | | PLANS, REPORTS, REVISIONS , PRODUCT APPROVALS AND OR | | | SUBMITTALS FOR REVIEW FOR PERMIT. IF YOUR PROJECT WILL | | | REQUIRE A RESIDENT INSPECTOR OR IF YOUR PROJECT IS A | | | THRESHOLD BUILDING REQUIRING A THRESHOLD INSPECTOR THEN | | | (3) THREE SETS OF ALL SAID DOCUMENTS WILL BE REQUIRED | | | FOR PERMIT ISSUANCE. 106.1* /2004 SUBMITTAL DOCUMENTS | | | WEST PALM BEACH ADMINISTRATIVE CODE. | | | | | | 1C) COMPLIED. | | | | | | 2) COMPLIED | | | | | | 3A) COMPLIED. | | | 3B)2ND REQUEST, DISCREPANCY IN SQUARE FEET BETWEEN THE | | | PLANS SHEET A0 AND THE COVERSHEET OF THE ENERGY PROJECT | | | SUMMARY SHEET. PLEASE CORRELATE DOCUMENTS. 106.1.2 | | | ADDITIONAL INFORMATION REQUIRED. | | | | | | 3C- 3D) COMPLIED. | | | | | | 4-5) COMPLIED. | | | | | | 6) FL BLD CODE 1609.6.2.2 COMPONENTS & CLADDING, | | | PROVIDE 2 COPIES OF PRODUCT TESTING REPORTS, MISSING | | | REPORTS ARE AS FOLLOWS: | | | 6A) FRONT ENTRY GLAZED DOOR KANEEER REPORTSUBMITTED WAS | | | FOR CURTAINWALL ONLY | | | | | | 6B) ROOFING CARLISLE SYNTES REPORT WAS SUBMITTED BUT ON | | | SHEET 7OF 9 THE INSULATION TYPE IS NOT CIRCLED, PROVIDE | | | LITERATURE FOR TYPE OF INSULATION TO BE USED TO | | | CORELATE WITH THE ENERGY CODE INPUT DATA REPORT | | | INDICATING A VALUE OF R-20.3. | | | THE SECOND ISSUE WITH THE CARLISLE REPORT IS FOUND ON | | | PAGE 8 OF 9. DEPENDING ON THE TYPE OF MEMBRANE TO BE | | | PICKED (CIRCLE) ALL 3 HAVE LOW VALUES IN ZONE 3 OF THE | | | FLAT ROOF, POSSIBLY ZONE 2 IF MEMBRANE # 1 IS PICKED, | | | THIS DESIGN HAS A MAXIMUM DESIGN PRESSURE OF -45 AND | | | LIMITATION #9 NO INHANCED FASTENING. BOTH SYSTEMS 2 & 3 | | | ARE A -60 WITH LIMITATION # 7 OR AN ALLOWABLE ENHANCED | | | FASTENING IS ALLOWED. | | | | | | 6C) STORM SHUTTERS OR PANELS SEMI-COMPLIED, PRODUCT | | | APRROVAL WAS SUBMITTED TOWN & COUNTRY INDUSTRIES NOA | | | 05-0713.02 NO SECTIONS WWERE CIRCLED NOR WAS THE TYPE | | | OF ANCHOR TO BE INSTALLED CIRCLED ON THE ANCHOR | | | SCHEDULE, EDGE DISTANCE CIRCLED NOR TYPE OF SUBSTRATE. | | | | | | 7-8) COMPLIED. | | | | | | 9A) STORM SHUTTER REPORT SUBMITTED PLEASE PROVIDE THE | | | FOLLOWING INFORMATION: PROVIDE STORM PANEL INFORMATION | | | WITH INSTALLATION SCHEDULE AND KEY PLAN WITH SPECIFIC | | | ANCHORS AND MOUNTING TO BE USED FOR ALL NON-IMPACT | | | GLAZING. FBC 1609.1.4. | | | | | | FL BLD CODE 2004 SECTION 106.3.3, | | | 1609.1.4, 1714.5.1 & EXIST BUILD CODE 507.3. | | | PROCEDURES: 1(B) A COMPLETE INSTALLATION SCHEDULE | | | SUMMARIZING & IDENTIFYING OPENING SIZES, STORY HEIGHTS, | | | UNIT MARK NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM BAR | | | REINFORCING REQUIREMENTS, WALL PRESSURE ZONES, SLAT | | | TYPES, ETC., SHALL BE SUBMITTED AT TIME OF PERMIT | | | APPLICATION TO FACILITATE PLAN REVIEW AND PERMIT | | | ISSUANCE. | | | | | | 9B-C) COMPLIED. | | | | | | 10-11) COMPLIED. | | | | | | 12A-B) COMPLIED. | | | | | | 12C) 2ND REQUEST, THE INDIVIDUAL TRUSS DRAWINGS | | | INDICATE THE DESIGN IS FOR A B EXPOSURE WHERE UNDER THE | | | 2007 SUPPLEMENTS ( 1609.2) THIS WILL BE WITHIN A C | | | ZONE, PLEASE CORRECT ASSUMPTIONS. THIS REVIEW THE | | | CORRECTIONS WERE MADE BY HAND. NO COVERL LETTER FROM | | | THE ENGINEER WAS SUBMITTED WITH THE CHANGE. THE OTHER | | | ISSUE WITH THE INDIVIDUAL TRUSS SHOP DRAWINGS IS THE | | | SHEETS HAVE A RUBBER SEAL OR COPIED SEAL ON EACH SHEET | | | AND THE SIGNATURE IS PHOTOCOPIED NOT ORIGINAL | | | SIGNATURES. THE TRUSS ENGINEER HAS TWO OPTIONS ONE IS | | | TO REPRINT ALL SHOP DRAWINGS AND THE HAND MADE | | | CORRECTION BE CORRECTED IN THE COMPUTER PROGRAM REPRINT | | | ALL SHEETS AND SIGNAND SEAL EACH SHEET OR LIST THE | | | CORECTIONS ON A INDEX/ COVER SHEET LIST ALL PAGES | | | COVERED BY THE COVER SHEET AND SIGN AND SEAL THIS ONE | | | PAGE. | | | | | | 61G15-23.002(2) FL. ADMIN. CODE. A COVER SHEET OR INDEX | | | SHEET FOR ENGINEERING SPECIFICATIONS MAY BE USED AND | | | THAT SHEET MUST BE SIGNED IN RESPONSIBLE CHARGE OF THE | | | PRODUCTION & PREPARATION OF EACH SECTION OF THE | | | ENGINEERING SPECIFICATION WITH SUFFICIENT INFORMATION | | | ON THE COVER SHEET OR INDEX. | | | | | | 13 ) BROVISO: FBC BUILDING 3110.1.2 / CITY OF WPB CODE | | | OF ORDINANCES SECTION 94-546. STRUCTURE IS LOCATED IN | | | AN "A" FLOOD ZONE. A FLOOD ELEVATION CERTIFICATE WILL | | | BE REQUIRED. | | | | | | 14) PROVISO: 109.3.10 IMPACT OF CONSTRUCTION. | | | | | | 15) PROVISO: 109.3.10.1 HURRICANE PROTECTION. | | | | | | 16) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)805-6731 | | | E-MAIL: [email protected] | | | | | | MEMBER OF BOAF, THE BUILDING OFFICIALS ASSOCIATION OF | | | FLORIDA: PROTECTING LIVES AND PROPERTY SINCE 1953. | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. UNDER FLORIDA STATE STATUTE SB80, E-MAIL ADDRESSES | | | ARE PUBLIC RECORDS.WRITTEN COMMUNICATIONS TO OR FROM | | | LOCAL OFFICIALS REGARDING CITY BUSINESS ARE PUBLIC | | | RECORD, AVAILABLE TO THE PUBLIC UPON REQUEST. YOUR | | | E-MAIL COMMUNICATIONS ARE THEREFORE SUBJECT TO PUBLIC | | | DISCLOSURE. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-10-30 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-10-30 |
Time |
09:57 |
Rev Time |
4.44 |
| Received By |
jwitmer |
Date |
2008-10-27 |
Time |
13:25 |
Sent To |
|
|
| Notes |
| 2008-10-30 16:55:51 | BUILDING PLAN REVIEW | | | PERMIT: 08100349 | | | ADD: 8132 OKEECHOBEE BLVD | | | CONT: MAJOR WORKING DRAWING REVIEW/ ANDREA CARDO | | | TEL: (954)654-5828 | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW | | | ACTION: DENIED | | | | | | 1A) INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE | | | INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | | | | 1B) INFORMATIONAL FL S S 713.13 NOTICE OF COMMENCEMENT, | | | TO BE FILED WITH THE CLERK OF THE COURT. NOTE: | | | 713.13(2) IF THE WORK DESCRIBED IN THE NOTICE OF | | | COMMENCEMENT IS NOT ACTUALLY COMMENCED WITHIN 90 DAYS | | | AFTER THE RECORDING THEREOF, SUCH NOTICE IS NULL & | | | VOID. NOTE: 713.13(6) THE POSTING OF THE NOTICE OF | | | COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE THE FIRST | | | INSPECTION. | | | | | | 1C) INFORMATIONAL: PLANS SUBMITTED FOR PERMIT (FIRST | | | TIME REVIEW) AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO | | | THE 2004 FBC BUILDING WITH THE 2007 SUPPLEMENTS, PLEASE | | | UPDATE THE SHEET AO TO THE 2007 FBC SUPPLEMENTS.. | | | | | | 2) PLEASE SUBMIT TWO ORIGINAL GEOTECHNICAL ENGINEERING | | | REPORTS THAT ARE SIGNED ANDSEALED, THE REPORTS | | | SUBMITTED ARE COLOR COPIES WITH COPIED SIGNATURES. | | | | | | PLANS, SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS | | | PREPARED BY THE DESIGN PROFESSIONAL AND BEING FILED FOR | | | PUBLIC RECORD SHALL HAVE THE SIGNATURE AND SEAL OF THE | | | DESIGN PROFESSIONAL AFFIXED TO THE DOCUMENT. | | | FL ADMIN CODE 61G15-23.002 ENGINEERS | | | | | | 1802.2.1 QUESTIONABLE SOIL. WHERE THE SAFE-SUSTAINING | | | POWER OF THE SOIL IS IN DOUBT, OR WHERE A LOAD-BEARING | | | VALUE SUPERIOR TO THAT SPECIFIED IN THIS CODE IS | | | CLAIMED, THE BUILDING OFFICIAL SHALL REQUIRE THAT THE | | | NECESSARY INVESTIGATION BE MADE. SUCH INVESTIGATION | | | SHALL COMPLY WITH THE PROVISIONS OF SECTIONS 1802.4 | | | THROUGH 1802.6 . | | | | | | 3) ENERGY CALCULATIONS: | | | | | | 3A) PLEASE CORRECT PROJECT SUMMARY CONCERNINING THE | | | ADDRESSING, THE CORRECT ADDRESS IS 8132 OKEECHOBEE | | | BLVD, OKEECHOBEE ROAD IS ANOTHER STREET THAT IS | | | PARTIALLY WITHIN THE CITY LIMITS, IN THIS ADDRESS RANGE | | | ON OKEECHOBEE ROAD IT WOULD BE OUTSIDE OF THE CITY | | | LIMITS. 106.1.2*. ADDITIONAL INFORMATION REQUIRED. | | | | | | 3B) DISCREPANCY IN SQUARE FEET BETWEEN THE PLANS SHEET | | | A0 AND THE COVERSHEET OF THE ENERGY PROJECT SUMMARY | | | SHEET. PLEASE CORRELATE DOCUMENTS. 106.1.2 ADDITIONAL | | | INFORMATION REQUIRED. | | | | | | 3C) INPUT DATA REPORT- WALL TYPE- INDICATES THE | | | EXTERIOR WALLS TO BE 2X6 FRAME WALLS WHILE SHEET A1 | | | INDICATES THE EXTERIOR WALLS AS A WALL TYPE P-30 AS A | | | 8" BLOCK WALL WITH 1 1/2" RIGID INSULATION, PLEASE | | | CORRECT THE DISCREPANCY. | | | | | | 3D) INPUT DATA REPORT INDICATES A ZONE 1 & 2 BOTH WITH | | | CONCRETE TILE ROOFING WHERE AS THE PLANS SHEET S4 DOES | | | INDICATE A LARGE PORTION OF THE ROOF TO BE A FLAT ROOF | | | WITH NO TILE. PLEASE CORRECT THE DISCREPANCY. | | | 106.1.2 ADDITIONAL INFORMATION REQUIRED. | | | | | | 4) SHEET A5 DETAIL 2 & 6 PLANS FAIL TO INDICATE | | | COMPLIANCE WITH TERMITE BARRIERS, PLEASE REVIEW 2114.2. | | | | | | 5) SHEET A5 DETAIL 4 &6 PLANS INDICATE THE USE OF WOOD | | | BUCKS, BUT THE BUCK DOES NOT SUPPORT THE FULL WIDTH OF | | | THE FRAME, SECTION 1714.5.4.2 STATES THAT UNLESS | | | OTHERWISE TESTED, BUCKS SHALL EXTEND BEYOND THE | | | INTERIOR FACE OF THE FRAME SUCH THATFULL SUPPORT OF THE | | | FRAME IS PROVIDED. | | | | | | 6) FL BLD CODE 1609.6.2.2 COMPONENTS & CLADDING, | | | PROVIDE 2 COPIES OF PRODUCT TESTING REPORTS, MISSING | | | REPORTS ARE AS FOLLOWS: | | | 6A) WALL LOUVERS- LARGE MISSILE IMPACT TESTING | | | REQUIRED, NO REPORT SUBMITTED | | | 6B) TRUSS ANCHORS- NO REPORT SUBMITTED | | | 6C) OUTSWING COMMERCIAL DOOR CECO DOOR REPORT SUBMITTED | | | IS EXPIRED 8-14-08 | | | 6D) EFIS- NOA SUBMITTED IS STO HI-PLY (LARGE MISSILE ON | | | PLYWOOD) PLANS CALL FOR BLOCK SEE SHEET A-1 WALL TYPE | | | P-30 EXCEPTION AT ATM MACHINE. | | | | | | 7) PRODUCT APPROVALS SUBMITTED WITH PERMIT APPLICATION | | | AFTER OCTOBER 1, 2003 ARE REQUIRED TO COMPLY WITH THE | | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR INFORMATION PLEASE | | | SEE THE STATE WEBSITE AT WWW.FLORIDABUILDING.ORG. | | | PRODUCTS WITH STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS THE PRODUCT | | | IDENTITY NUMBER FROM THE STATE. IF THE PRODUCT DOES NOT | | | HAVE STATEWIDE APPROVAL, SUBMIT AN APPLICATION FOR | | | LOCAL PRODUCT APPROVAL OR SITE SPECIFIC FORM PER RULE | | | 9B-72. SEE ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 8) WPB ADMIN CODE 106.3* PRODUCT APPROVALS. THOSE | | | PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | | | | 9A) STORM SHUTTER REPORT SUBMITTED PLEASE PROVIDE THE | | | FOLLOWING INFORMATION: PROVIDE STORM PANEL INFORMATION | | | WITH INSTALLATION SCHEDULE AND KEY PLAN WITH SPECIFIC | | | ANCHORS AND MOUNTING TO BE USED FOR ALL NON-IMPACT | | | GLAZING. FBC 1609.1.4. | | | | | | FL BLD CODE 2004 SECTION 106.3.3, | | | 1609.1.4, 1714.5.1 & EXIST BUILD CODE 507.3. | | | PROCEDURES: 1(B) A COMPLETE INSTALLATION SCHEDULE | | | SUMMARIZING & IDENTIFYING OPENING SIZES, STORY HEIGHTS, | | | UNIT MARK NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM BAR | | | REINFORCING REQUIREMENTS, WALL PRESSURE ZONES, SLAT | | | TYPES, ETC., SHALL BE SUBMITTED AT TIME OF PERMIT | | | APPLICATION TO FACILITATE PLAN REVIEW AND PERMIT | | | ISSUANCE. | | | | | | 9B) STORM PANEL PRODUCT APPROVAL SHEEET 1 OF 6 | | | INDICATES THE USE OF A BUILT OUT MOUNT CLOSURE DETAIL | | | WHILE SHEET A16 DOES INDICATE THE TOP AND BOTTOM MOUNT | | | INFORMATION THE PLANS DO NOT INCORPORATE THE BUILT OUT | | | MOUNT DETAIL WITH TWO DIFFERENT SURFACES (STONE & EFIS) | | | AND STAND OFF DIMENSIONS. PLEASE PROVIDE ADDITIONAL | | | VIEWS FOR THIS TYPE OF APPLICATION. 106.1.2 ADDITIONAL | | | INFORMATION REQUIED, 1609.6.2.2. | | | | | | | | | 9C) SHEET A16 DETAIL # 3 HEADER DETRAIL FOR STORM PANEL | | | HEADER TRACK INDICATES THE TYPE OF LAG SCREW FOR THE | | | STORM PANEL HEADER BUT THERE IS NO INFORMATION ON THE | | | ATTTACHMENT OF THE 2X MEMBERS TO THE | | | BLOCK WALL. 106.2.2 ADDITIONAL INFORMATION REQUIRED. | | | 1609.6.2.2. | | | | | | 10) SHEET S-1 UNDER CODES & STANDARDS INDICATES | | | DESIGNED TO THE ASCE 7-98 , PLEASE CORRECT TO ASCE | | | 7-02, 2004 FBC 1609.1.1 & CHAPTER 35 REFERENECED | | | STANDARDS RECOGNIZES ASCE 7-02 . ALSO 1603.1.4 WIND | | | DESIGN DATA. | | | | | | 11) SHEET S4 VERSES THE TRUSS ENGINEERING SHOP DRAWINGS | | | AND TRUSS LAY OUT SHEET FROM THE TRUSS COMPANY: | | | | | | 11A) STRUC PLAN (S4) TRUSS GT2/ T4 TRUSS DRAWING THE | | | STRUCTURAL PLAN INDICATES THIS GIRDER AS A TWO PLY | | | GIRDER WHERE AS THE TRUSS COMPANY HAS MADE IT A 3 PLY | | | GIRDER, THIS WILL AFFECT THE TYPE OF TRUSS ANCHORS | | | LISTED IN THE TIE DOWN SCHEDULE FOR THIS GIRDER. | | | | | | 11B) STRUC PLAN (S4) TRUSS GT2/ T4 TRUSS DRAWING THE | | | STRUCTURAL PLAN THIS SAME GIRDER AT THE INTERIOR | | | BEARING POINT HAS A REACTION OF 27,813 LBS. EXCEEDING | | | THE SAFE VALUE OF 13,983.75 LBS /34.75 SQ INCHES | | | REQUIRING ADDITONAL STRUCTURAL ENGINEERING, NOTE ALSO | | | THERE IS NO SECTION THROUGH THIS GIRDER BUT S5 DETAIL# | | | 7 WILL HAVE SIMILAR ISSUES | | | | | | 11C) STRUC PLAN (S4) TRUSS GT1/ T5 TRUSS DRAWING THE | | | STRUCTURAL PLAN THIS GIRDER AT THE INTERIOR BEARING | | | POINT HAS A REACTION OF 21,605 LBS. EXCEEDING THE SAFE | | | VALUE OF 9,322 LBS /16.50 SQ INCHES REQUIRING ADDITONAL | | | STRUCTURAL ENGINEERING, | | | | | | 12) THE TRUSS DRAWING COVER SHEET FROM ITW BUILDING | | | COMPONENTS GROUP : | | | | | | 12A) NEEDS TO CORRECT THE LOCATION OF THE PROJECT TO | | | 8132 OKEECHOBEE BLVD, OKEECHOBEE ROAD WOULD BE LOCATED | | | IN THE COUNTY. | | | | | | 12B) UNDER THE MODEL CODE THE COVER SHEET DOES NOT | | | INCLUDE THE 2007 FBC SUPPLEMENTS. | | | | | | 12C) THE INDIVIDUAL TRUSS DRAWINGS INDICATE THE DESIGN | | | IS FOR A B EXPOSURE WHERE UNDER THE 2007 SUPPLEMENTS ( | | | 1609.2) THIS WILL BE WITHIN A C ZONE, PLEASE CORRECT | | | ASSUMPTIONS. | | | | | | 13) THE ADDRESSS INDICATES THIS AREA TO BE WITHIN A AH | | | FLOOD ZONE, FBC BUILDING 3110.1.2 / CITY OF WPB CODE OF | | | ORDINANCES SECTION 94-546. STRUCTURE IS LOCATED IN AN | | | "A" FLOOD ZONE. A FLOOD ELEVATION CERTIFICATE WILL BE | | | REQUIRED BEFORE A CERTIFICATE OF OCCUPANCY WILL BE | | | ISSUED. | | | | | | 14) 109.3.10* IMPACT OF CONSTRUCTION. ALL CONSTRUCTION | | | ACTIVITY REGULATED BY THIS CODE SHALL BE PERFORMED IN A | | | MANNER SO AS NOT TO ADVERSELY IMPACT THE CONDITION OF | | | ADJACENT PROPERTY, UNLESS SUCH ACTIVITY IS PERMITTED TO | | | AFFECT SAID PROPERTY PURSUANT TO A CONSENT BY THE | | | APPLICABLE PROPERTY OWNER, UNDER TERMS & CONDITIONS | | | AGREEABLE TO THE APPLICABLE PROPERTY OWNER. THIS | | | INCLUDES BUT IS NOT LIMITED TO THE CONTROL OF DUST, | | | NOISE, WATER OR DRAINAGE RUN-OFF, DEBRIS, AND THE | | | STORAGE OF CONSTRUCTION MATERIALS. NEW CONSTRUCTION | | | ACTIVITY SHALL NOT ADVERSELY IMPACT HISTORIC SURFACE | | | WATER DRAINAGE FLOWS SERVING ADJACENT PROPERTIES, & MAY | | | REQUIRE SPECIAL DRAINAGE DESIGN COMPLYING WITH | | | ENGINEERING STANDARDS TO PRESERVE THE | | | POSITIVE PATTERNS OF THE AFFECTED SITES. ACCORDINGLY, | | | DEVELOPERS, CONTRACTORS, AND OWNERS OF ALL NEW | | | RESIDENTIAL DEVELOPMENT, INCLUDING ADDITIONS, POOLS, | | | PATIOS, DRIVEWAYS, DECKS, OR SIMILAR ITEMS, ON EXISTING | | | PROPERTIES RESULTING IN A DECREASE IN EXCESS OF 800SQ | | | FT OF PERMEABLE LAND AREA ON ANY PARCEL SHALL AS A | | | PERMIT CONDITION, PROVIDE A PROFESSIONALLY PREPARED | | | DRAINAGE PLAN CLEARLY INDICATING COMPLIANCE WITH THIS | | | PARAGRAPH. UPON COMPLETION OF THE IMPROVEMENT, A | | | CERTIFICATION FROM A LICENSED ENGINEER SHALL BE | | | SUBMITTED TO THE INSPECTOR IN ORDER TO RECEIVE APPROVAL | | | OF THE FINAL INSPECTION. | | | | | | 15) 109.3.10.1 HURRICANE PROTECTION. IT SHALL BE | | | UNLAWFUL FOR ANY PERSON TO ALLOW CONSTRUCTION RELATED | | | MATERIALS EQUIPMENT AND DEBRIS TO REMAIN LOOSE OR | | | OTHERWISE UNSECURED AT A CONSTRUCTION SITE FROM 24 HRS. | | | AFTER A HURRICANE WATCH HAS BEEN ISSUED UNTIL THE | | | HURRICANE WATCH OR WARNING HAS BEEN LIFTED. ALL SUCH | | | CONSTRUCTION MATERIALS, EQUIPMENT AND DEBRIS SHALL BE | | | EITHER REMOVED FROM THE CONSTRUCTION SITE OR SECURED IN | | | SUCH A MANNER AS TO MINIMIZE THE DANGER OF SUCH | | | CONSTRUCTION MATERIALS, EQUIPMENT AND DEBRIS CAUSING | | | DAMAGE TO PERSONS OR PROPERTY FROM HIGH WINDS. ANY | | | PERSONS WHO FAILS TO COMPLY TO REMOVE OR SECURE THE | | | CONSTRUCTION MATERIALS EQUIPMENT AND DEBRIS WITHIN 24 | | | HRS AFTER A HURRICANE WATCH HAS BEEN ISSUED SHALL BE | | | SUBJECT TO A FINE NOT TO EXCEED $500.00. IN ADDITION TO | | | THE ABOVE, A LICENSED CONTRACTOR WHO VIOLATES THIS | | | SECTION SHALL BE SUBJECT TO DISCIPLINE PURSUANT TO | | | SECTION 113 OF THIS CHAPTER. | | | | | | 16) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2010-03-18 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2010-03-18 |
Time |
13:31 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2010-03-18 |
Time |
12:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2010-01-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2010-01-15 |
Time |
14:19 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2010-01-15 |
Time |
14:19 |
Sent To |
|
|
| Notes |
| 2010-01-15 14:20:38 | | | | ** DENIED 4TH REVIEW * | | | | | | ** SECOND REVIEW UNDER ACTUAL PERMIT APPLICATION. FIRST | | | TWO REVIEWS WERE UNDER * PLAN REVIEW ONLY*. | | | | | | 1) NOTE: PLEASE SEE FS 553.80(2)(B) WITH RESPECT TO | | | REPEAT COMMENTS FOR THE SAME CODE SECTIONS NOTED ON | | | EACH REVIEWS. THIS IS THE SECOND REVIEW UNDER ACTUAL | | | PERMIT APPLICATION, IF PLANS COME BACK IN FOR ONE MORE | | | REVIEW WITH THE SAME CODE COMPLIANCE COMMENTS NOTED A | | | 4X FEE FOR THE PLAN REVIEW PORTION OF THE PERMIT FEE | | | SHALL BE ASSESSED. THIS IS ONLY GIVEN AS A NOTICE AT | | | THIS TIME. | | | | | | 2) NOTE: IN AN EFFORT TO ALLEVIATE FURTHER REVIEWS AND | | | REPEAT COMMENTS THIS REVIEWER CALLED FIRM LISTED ON | | | TITLE BLOCKS REQUESTING TO SPEAK TO THE ENGINEER OF | | | RECORD. THE STAFF INDIVIDUAL FIRST STATED NO SUCH | | | PERSON WORKED FOR THEIR FIRM. AFTER SEVERAL QUESTIONS, | | | STAFF THEN STATED THIS ENGINEER WAS ACTUALLY AN OUTSIDE | | | CONSULTANT AND DID NOT WORK FOR INTERPLAN. THE CALL WAS | | | NOT RECEIVED WELL AND STAFF DID NOT SEEM TO KEEP | | | ATTENTION TO CALL. CALL WAS TERMINATED BY REVIEWER AS | | | NO ACCOMPLISHMENT WAS BEING MADE. | | | ENGINEER OF RECORD SHALL LIST HIS OR HER INFORMATION ON | | | TITLE BLOCK IF THEY ARE NOT UNDER THE DIRECT EMPLOYMENT | | | OF FIRM LISTED. PLEASE CONTACT BOARD OF ENGINEERS AND | | | DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION. | | | THIS HAS BEEN CONFIRMED WITH FBPE. | | | THE STATE HAD THE INFORMATION FOR ENGINEER OF RECORD IS | | | WITH DESIGN PLUS INC. PLEASE PROVIDE CERTIFICATE OF | | | AUTHORIZATION NUMBER AS LISTED WITH THE STATE OF | | | FLORIDA. | | | | | | DESIGN PLUS INC | | | 664 OAK HOLLOW WAY | | | ALTAMONTE SPRINGS, FL. 32714 | | | CA # 26340 | | | ** THIS INFORMATION IS REQUIRED ALSO ON MECHANICAL | | | SHEETS. | | | ** TO ALLEVIATE RE-PRINTING OF ALL SHEETS, THIS MAY BE | | | ADDED BY A STAMP, TITLE BLOCK STICKER OR NEATLY | | | HANDWRITTEN. | | | | | | PLEASE PROVIDE REVISED TITLE BLOCK FOR ENGINEER OF | | | RECORD. PLEASE SEE FLORIDA ADMINISTRATIVE CODE | | | 61G15-23.002, FS 471.025, 471.023. | | | | | | 3) NOTE: AS REQUESTED ON ALL PREVIOUS REVIEWS PLEASE BE | | | SURE TO SEE FBC 13-415.AB.5, 13-415.AB.2.2 AND | | | 13-400.0.A, 13-101.1.1 | | | PLEASE BE SURE ALL SYSTEMS, COMPONENTS AND ITEMS ON | | | PLANS WHICH AFFECT THE ENERGY CONSUMPTION AND | | | EFFICIENCY OF THE BUILDING ARE PLACED INTO THE INPUT | | | DATA REPORT OF THE SUBMITTED CALCULATIONS. | | | A) ALL EXTERIOR LIGHTING IS REQUIRED TO BE PLACED INTO | | | THE IDR. THIS WAS SPECIFICALLY MENTIONED ON THE | | | PREVIOUS REVIEW YET THERE ARE SOME FIXTURES STILL NOT | | | PART OF THE IDR. THE SAME FIXTURES WERE NOTED ABOVE A | | | CALL WAS PLACED TO FIRM TO FIND OUT WHERE ALL OF THE | | | 1000W FIXTURES AND 400WATT FIXTURES ARE FED FROM. THESE | | | ARE SHOWN ON SITE PHOTO-METRICS, HOWEVER NONE OF THESE | | | FIXTURES ARE IN THE IDR. | | | PLEASE E-0 INDICATES 3 MWD FIXTURES ON EXTERIOR WALLS | | | HOWEVER LIGHTING PLANS ONLY INDICATE ONE OF THESE | | | FIXTURES? THE ADDITIONAL FIXTURES ARE NOT IN THE IDR | | | EITHER? | | | CIRCUITING? CIRCUITING ON SCHEDULES? | | | ONLY THE MINIMUM NEEDS TO BE SHOWN AT THIS TIME. | | | | | | 4) NOTE: PREVIOUS NOTE WITH RESPECT TO 250.94 AND | | | INTERSYSTEM BONDING WAS ADDRESSED BY A SPEC SHEET FOR | | | SPECIFICATION BOOK. PLEASE PROVIDE ON PLANS. | | | SPECIFICATION BOOKS ARE NOT USED FOR INSPECTIONS. | | | IF THIS IS THE ONLY COMMENT WHICH NEEDS TO BE DONE, | | | PLANS CAN BE REDLINED WITH THIS INFORMATION FROM | | | REVIEWER AND REVISED AT A LATER DATE. | | | | | | 5) NOTE: PREVIOUS NOTE WITH RESPECT TO 406.8 WAS NOT | | | REVISED ON PLANS. RESPONSE MENTION NOTED ADDED TO SHEET | | | E-4 HOWEVER NOTE COULD NOT BE FOUND. THIS CAN ALSO BE | | | RED-LINED WITHOUT REVISING SHEET. | | | | | | 6) NOTE: PREVIOUS NOTE #8, RESPONSE MENTIONS TO BE | | | HARD-WIRED, HOWEVER PLEASE KNOW THIS STILL DOES NOT | | | ALLOW THE USE OF CORDS. | | | THIS CAN BE REDLINED ON PLANS. PLEASE BE SURE TO VERIFY | | | LISTING OF EQUIPMENT SO THAT LISTING IS NOT VOIDED. | | | 400.8(2) | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2009-10-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-10-30 |
Time |
10:50 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-10-30 |
Time |
10:50 |
Sent To |
|
|
| Notes |
| 2009-10-30 10:51:01 | ** DENIED ** | | | | | | 1) NOTE: AS NOTED ON PREVIOUS REVIEW PLANS HAD NOT BEEN | | | SUBMITTED FOR PERMIT THEREFORE ALL PLANS AND SUPPORTING | | | DOCUMENTS WOULD BE REQUIRED TO BE REVISED BASED ON THE | | | CODE AT THE TIME OF PERMIT APPLICATION. | | | THE RESPONSE MENTIONS PLANS WERE REVISED TO THE 2007 | | | FLORIDA BUILDING CODE HOWEVER SUBMITTED ENERGY | | | CALCULATIONS ARE FROM THE 2004 FLORIDA BUILDING CODE. | | | PLEASE ALSO KNOW THAT AS OF OCTOBER 1ST, 2009 THE | | | FLORIDA BUILDING CODE AND OTHER ADOPTED CODES HAVE ONCE | | | AGAIN CHANGED. THE SECOND SET OF 2009 SUPPLEMENTS OF | | | THE 2007 FBC HAVE BEEN IMPLEMENTED AND ADOPTED BY | | | STATUTES. | | | THIS INCLUDES THE ADOPTION OF THE 2008 NFPA-70. | | | ON THE PREVIOUS REVIEW NOTES WERE GIVEN FOR CODES. | | | THE PLANS STATE THE 2007 NFPA-101 HOWEVER PREVIOUS | | | REVIEW HAVE NOTE TO THE 2006 NFPA-101 AS ADOPTED ON | | | DECEMBER 31ST, 2008. THERE IS NO 2007 NFPA-101. | | | THE PLANS ALSO STATE THE 2007 NATIONAL ELECTRICAL CODE. | | | HOWEVER PREVIOUS NATIONAL ELECTRICAL CODE WAS THE 2005 | | | EDITION AND NOW THE 2008 EDITION HAS BEEN ADOPTED. | | | PLEASE BE SURE TO GO THROUGH THE 2008 NEC FOR NUMEROUS | | | CHANGES AND REVISE PLANS ACCORDINGLY. | | | | | | 2) NOTE: AS NOTED ON PREVIOUS REVIEW PLEASE COORDINATE | | | ALL ITEMS ON PLANS WITH THE SUBMITTED ENERGY | | | CALCULATIONS. | | | THE INPUT DATA REPORT AND PLANS DO NOT MATCH. 13-101.1, | | | 13-400.0.A,13-400.3.AB.3, 13-415.AB.5, 13-415.AB.2.2 | | | ETC | | | | | | EXAMPLE: THE IDR STILL DOES NOT INDICATE ALL EXTERIOR | | | LIGHTING LOCATED ON PLANS. IN FACT THE IDR ONLY | | | INDICATES A TOTAL OF THREE 100W LIGHT FIXTURES. THIS IS | | | NOT POSSIBLE WHEN SHEET E-2 CONTAINS MORE THAN 30 | | | FIXTURES. SHEET E2 CONTAINS NUMEROUS 1080W FIXTURES, | | | SEVERAL 455W MH FIXTURES, ETC. THE TOTAL NUMBER OF 100W | | | MLD FIXTURES IS 19. | | | THERE ARE OTHERS. | | | EXAMPLE: THE IDR INDICATES CARPET AND RUBBER PADDING | | | FOR ALL AREAS INCLUDING ZONE #4 WHICH CAN NOT CONTAIN | | | CARPET AND RUBBER PADDING. | | | | | | EXAMPLE: PLEASE SEE THE IDR WHICH INDICATES MANUAL ON/ | | | OFF CONTROLS WHICH IS NOT ACCURATE. | | | | | | EXAMPLE: PLEASE REVISE THE INTERIOR LIGHTING WHICH HAS | | | BEEN REVISED ON PLANS. | | | | | | 3) NOTE: NEW NOTE FOR 2008 NEC. PLEASE SEE 250.94 FOR | | | REQUIRED INTERSYSTEM BOND. | | | THE NEW SPECS BOOKS SUBMITTED CONTAIN A REFERENCE TO A | | | 250.94C, HOWEVER THIS IS FROM SEVERAL CODE CYCLES AGO | | | AS THERE IS NO CURRENT 250.94C. (1996 NEC). | | | PLEASE PROVIDE DETAILS FOR NEW REQUIRED BOND. | | | | | | 4) NOTE: PLEASE SEE 406.8 FOR REQUIRED RECEPTACLES | | | OUTSIDE IN DAMP OR WET LOCATIONS. | | | | | | 5) NOTE: PLEASE SEE FS 655.692. PLANS CONTAIN A NOTE #7 | | | ON SHEET E-2 WHICH STATE A 2 FOOT CANDLE MINIMUM IN THE | | | 5FT RADIUS FOR ATM. HOWEVER PER 655.962 (1)(A) REQUIRES | | | 10FT CANDLE. THE AREAS OUT FROM THERE INCLUDE 2 FT | | | CANDLE FOR 50FT AND PARKING REQUIREMENTS. | | | | | | 6) NOTE: ON PREVIOUS REVIEW IT WAS REQUESTED TO SUBMIT | | | THE MANUFACTURES SPECS/CUT SHEET FOR THE PROPOSED | | | TRANSFER SWITCH. THE RESPONSE MENTIONS IT WILL BE | | | LISTED HOWEVER NO SPECS OR SPECIFIC INFORMATION WAS | | | SUBMITTED. THERE ARE PRODUCTS AVAILABLE WHICH ARE NOT | | | 1008 LISTED OR MEET MINIMUM STANDARDS FOR TRANSFER OF | | | POWER. NEC 702.4,702.5 ( ALL) , 702.6, 90.7, 110.3 ETC | | | | | | 7) NOTE: PREVIOUS REVIEW NOTES WITH RESPECT TO MINIMUM | | | WIND LOADS TO BE ON PLANS PER 1609 OF THE FBC ARE NOT | | | DONE. RESPONSE MENTIONS NOTES ADDED TO PLANS HOWEVER NO | | | WIND LOAD INFORMATION IS ON SITE PLANS. | | | | | | 8) NOTE: PLANS INDICATE RECEPTACLES FOR DYE PACKS ABOVE | | | CEILING. HOWEVER PER 400.8(2) CORD AND PLUG CONNECTIONS | | | ABOVE CEILINGS ARE NOT PERMITTED. THIS INCLUDES CORDS | | | AS NOTED. | | | | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2009-01-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-01-30 |
Time |
11:08 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-01-29 |
Time |
12:44 |
Sent To |
|
|
| Notes |
| 2009-01-30 11:08:31 | ** DENIED PLANS** | | | | | | 1) NOTE: PLANS HAVE STILL ONLY BEEN SUBMITTED FOR PLAN | | | REVIEW ONLY AND HAVE NOT BEEN SUBMITTED UNDER PERMIT | | | APPLICATION. IN ORDER FOR PROJECT TO FALL UNDER THE | | | CURRENT CODE CYCLE PERMIT APPLICATION MUST BE MADE WITH | | | REQUIRED FEES PAID BEFORE MARCH 1ST, 2009. | | | ALL PERMIT APPLICATIONS MADE ON THIS DATE OR AFTER WILL | | | FALL UNDER THE NEW CODE CYCLES OF THE 2007 FBC. | | | | | | 2) NOTE: THE LIFE SAFETY CODE HAS ALREADY BEEN CHANGED | | | PER STATE FIRE MARSHAL AS OF DEC 31ST, 2008. THIS | | | SHOULD BE NOTED ON PLANS TO READ NFPA-101 2006. | | | | | | 3) NOTE: AS STATED ON THE PREVIOUS REVIEW. PLEASE BE | | | SURE ALL INFORMATION ON THE SUBMITTED INPUT DATA REPORT | | | WHICH IS PART OF THE ENERGY CALCULATIONS COORDINATES | | | WITH THE SUBMITTED PLANS. AS NOTED PREVIOUSLY, THE | | | NUMBER OF FIXTURES, THE TYPES OF FIXTURES, THE WATTAGE | | | OF FIXTURES ETC ARE ALL REQUIRED TO MATCH WITH THE | | | SUBMITTED PLANS. | | | ONE EXAMPLE GIVEN BELOW OF ITEMS WHICH ARE NOT CODE | | | COMPLIANT ON THE SUBMITTED CALCULATIONS IS THE EXTERIOR | | | LIGHTING. THE IDR ONLY INDICATES A TOTAL OF 3 LIGHT | | | FIXTURES ALL BEING THE SAME WATTAGE. THIS IS NOT | | | POSSIBLE AS THE SUBMITTED PLANS CONTAIN ALMOST TWO | | | DOZEN FIXTURES AND NOT ALL OF THESE ARE THE SAME TYPE | | | OF FIXTURE. | | | PLEASE REVISE AND UPDATE CALCULATIONS. THIS IS ONE | | | EXAMPLE ONLY AND IS NOT A LIST OF ALL POSSIBLE ITEMS. | | | PLEASE SEE WATER HEATER AS ANOTHER. | | | 13-415.2.ABC.1.1,.1.2 AND .1.3 | | | 13-412.1.ABC.3.4.1 | | | ** ALSO SEE NOTES WITH RESPECT TO FLOORING IN EVERY | | | AREA OF THE ENTIRE BUILDING WHICH IS WHAT IS SHOWN ON | | | THE IDR FOR ALL FLOORS. THIS WILL AFFECT THE ELECTRICAL | | | SERVICE EQUIPMENT AS WELL AS PANELS. | | | | | | 4) NOTE: PLEASE PROVIDE LISTING OF THE PROPOSED MANUAL | | | TRANSFER SWITCH. IS THIS A LISTED 1008 ENCLOSURE? COULD | | | NOT LOCATE LISTING AS A AUTOMATIC OR MANUAL ON PRODUCT | | | DATA SUBMITTED. | | | 702.6,110.3,90.7 | | | | | | 5) NOTE: ON THE PREVIOUS REVIEW A REQUEST WAS MADE TO | | | PROVIDE PRODUCT DATA SHEETS FOR THE PROPOSED UPS. THESE | | | SHEETS NEEDED TO INDICATE A LISTING FROM A NRTL. THIS | | | OFFICE/REVIEWER COULD NOT LOCATE ANY LISTING FROM ANY | | | NRTL ON THE DOCUMENTS SUBMITTED. | | | 110.3,90.7, FBC 106.1.1, 106.1.2 FOR ADDITIONAL | | | INFORMATION AND COORDINATION | | | | | | 6) NOTE: AS BRIEFLY NOTED ABOVE IN NOTE #3 THE IDR OF | | | THE ENERGY CALCULATIONS FOR FLOORS STATES CARPET AND | | | RUBBER PADDING FOR ALL AREAS AND FLOORS OF THE | | | BUILDING. THIS IS NOT POSSIBLE AS CARPET AND RUBBER | | | PADDING IS NOT PERMITTED IN THE AREAS WHERE THE | | | ELECTRICAL PANELS AND OVER CURRENT PROTECTION IS | | | LOCATED. | | | 240.24,408.36 ETC | | | | | | 7) NOTE: PLEASE SEE 13-415.1.ABC.1.2 FOR REQUIRED | | | CONTROLS FOR BREAK ROOM OR CONFERENCE ROOMS. THIS IS | | | ABOVE THE REQUIREMENT FOR BUILDINGS GREAT THAN 5K SQ | | | FT. | | | ** NOTE IDR FOR CONTROL METHODS* | | | | | | 8) NOTE: PLEASE COMPLETE ELECTRICAL PLANS AS NOTED ON | | | PREVIOUS REVIEW. THE SITE LIGHTING PLANS FOR EXAMPLE DO | | | NOT SHOW ANY CIRCUITING. THESE ARE NOT FIGURED INTO THE | | | ENERGY CALCULATIONS. | | | 240.4,310.16,408.4,220, FBC 13-415.1.ABC.1.4, | | | 13-415.2.ABC.1.3 | | | ** | | | PLEASE SEE COMMENTS WITH RESPECT TO MINIMUM DESIGN FOR | | | WIND LOADS PER TABLE 1609. THE SITE LIGHTING PLANS NEED | | | TO SHOW MINIMUM WIND LOADS. CALCULATIONS WILL BE | | | REQUIRED FOR ANY POLE LIGHTING SEPARATELY UNDER | | | BUILDING REVIEW. | | | | | | 9) NOTE: PLEASE BE SURE THE FOLLOWING CODES ARE LISTED | | | ON THE ELECTRICAL PLANS. | | | 2004 FBC W/ 2007 REVISIONS. | | | 2005 NFPA-70 | | | | | | 10) NOTE: PLEASE BE SURE ALL PANEL SCHEDULES ARE | | | SPECIFIC TO ROOMS AND AREAS IN WHICH THEY FEED. FOR | | | EXAMPLE: INSTEAD OF *RECEPTACLES OFFICE* THIS WOULD | | | ACTUALLY LIST THE ACTUAL DESIGNATION OF EACH OF THE | | | ROOMS. PLEASE BE SURE ALL ROOMS CONTAIN EITHER ALPHA OR | | | NUMERIC DESIGNATIONS. | | | | | | 11) NOTE: AS PROJECT HAS NOT APPLIED FOR PERMIT | | | VALUATION CAN NOT BE CONFIRMED PER FBC108.3. | | | | | | | | | | | | | | | | | | | | | | | | ** IMPORTANT ** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED | | | INTO TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2008-10-31 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-10-31 |
Time |
17:00 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-10-31 |
Time |
17:00 |
Sent To |
|
|
| Notes |
| 2008-10-31 17:00:53 | | | | | | | | | | | | | ** DENIED REVIEW ** | | | | | | 1) NOTE: PROJECT INFORMATION HAS BEEN FORWARDED TO THE | | | ADDRESSING REVIEW TO CORRECT ADDRESS DISCREPANCIES. THE | | | APPLIED LOCATION IS 8132 W OKEECHOBEE BLVD HOWEVER THE | | | PLANS AND OTHER SUPPORTING DOCUMENTS SUCH AS ENERGY | | | CALCULATIONS STATE OKEECHOBEE ROAD WHICH IS AN ENTIRELY | | | DIFFERENT LOCATION AND STREET. | | | PLEASE ADJUST PLANS AND CORRECT ADDRESS ONCE FINAL | | | DETERMINATION IS MADE. | | | FBC 106.5 | | | FAC 61G1-16.004, 61G15-23.002 | | | | | | 2) NOTE: PLEASE SEE THE PLANS HAVE COME IN FOR PLAN | | | REVIEW ONLY AND HAS NOT BEEN SUBMITTED FOR PERMIT. ONCE | | | PLANS MEET CODE COMPLIANCE AND PERMIT APPLICATION HAS | | | NOT BEEN MADE THE REVIEW WILL STILL REMAIN IN A FAILED | | | STATUS UNTIL PERMIT APPLICATION IS MADE. THE LICENSING | | | OF ALL DESIGNERS AND CONTRACTORS WILL BE VERIFIED AT | | | THAT POINT. | | | | | | 3) NOTE: PLEASE BE SURE THE SUBMITTED ENERGY | | | CALCULATIONS AND THE INPUT DATA REPORT COORDINATES WITH | | | THE SUBMITTED. PLANS. THE NUMBER OF FIXTURES, THE TYPE | | | OF FIXTURES, THE WATTAGES AND THE CONTROLS NEED TO | | | MATCH WITH THE PLANS. | | | THE IDR SHOWS FOR INTERIOR LIGHTS A TOTAL OF THREE | | | FIXTURES WHICH IS NOT POSSIBLE BASED ON THE PLANS. THE | | | IDR STATES CLEARLY AT THE TOP OF THE LIGHTING FIELD *** | | | NO OF LUMINAIRES*, ** WATTS PER LUMINAIRE* ETC. THIS | | | DOES NOT INCLUDE ANY IDENTIFICATION OF USING JUST ONE | | | FIXTURE AND A TOTAL. BASED ON THE PLANS SUBMITTED EVEN | | | IF USING ONE TOTAL WATTAGE THE AMOUNT WOULD STILL NOT | | | CORRELATE. | | | PLEASE REVISE AND ADJUST ALL. | | | PLEASE BE SURE TO SEE THE SPECIFIC SECTIONS BELOW FOR | | | INTERIOR ALLOWANCES AND HOW VA LOADS OF FIXTURES AND | | | ANY TRACK IS REQUIRED TO BE ENTERED. | | | 13-400.3A, 13-101, 13-415.2, 13-415.2.ABC.1.1, .1.2 AND | | | .1.3. | | | | | | | | | 4) NOTE: PLEASE BE SURE THE FOLLOWING CODES ARE LISTED | | | ON PLANS AS WELL AS ON ELECTRICAL PLANS. SOME CODES | | | REFERENCES ON PLANS ARE NO LONGER ADOPTED BY THE STATE | | | OF FLORIDA AND HAVE NOT BEEN FOR OVER A DECADE. PLEASE | | | SEE SHEET E1 FOR EXAMPLE WHICH STATES THE *1996 | | | NATIONAL ELECTRICAL CODE**. PLEASE BE SURE TO CORRECT | | | CODES REFLECTED ON PLANS. | | | THE FOLLOWING SHALL BE LISTED AT A MINIMUM FOR THIS | | | REVIEWER AND FOR THIS TRADE. | | | | | | 2004 FBC W/ 2007 REVISIONS. | | | 2005 NFPA-70 | | | 2003 NFPA-101 | | | 2002 NFPA-72 (WHEN APPLICABLE) | | | | | | 5) NOTE: ( FOR CONTRACTOR) | | | THE APPLIED VALUE FOR COMPLETE SCOPE OF WORK SHALL | | | INCLUDE ALL LABOR, MATERIALS, DESIGN COST, EQUIPMENT | | | ETC EVEN IF ANY OF THESE ITEMS ARE OWNER SUPPLIED. | | | FBC 108.3 | | | | | | 6) NOTE: PLEASE SUBMIT THE MANUFACTURE SPECS/CUT SHEETS | | | FOR THE PROPOSED UPS. 90.7,110.3 | | | | | | 7) NOTE: PLEASE SUBMIT THE MANUFACTURE SPECS/CUT SHEETS | | | FOR THE PROPOSED MTS. 90.7,110.3. | | | | | | 8) NOTE: PLEASE KNOW SEPARATE SYSTEMS SUCH AS THE LOW | | | VOLTAGE FOR CAMERAS, PHONE, DATA ETC SHALL BE UNDER A | | | SEPARATE PERMIT. THE LV FOR SECURITY WILL ALSO BE UNDER | | | A SEPARATE PERMIT. THE SECURITY SYSTEM SHOP DRAWINGS | | | SHOWING SPECIFICS ARE NOT REQUIRED BY THIS OFFICE IN | | | FAC T HAVING THESE PLANS ON RECORD FILE FOR PUBLIC | | | ACCESS IS NOT REQUIRED. BASE PLANS SHOWING CAMERA | | | LOCATIONS, ANY ACCESS CONTROLS IS REQUIRED. PLEASE CALL | | | TO GO OVER SPECIFICS OR FOR ANY QUESTIONS REGARDING | | | SYSTEMS. | | | **FBC 105.1, 106.1.1 | | | | | | 9) NOTE: PLEASE COMPLETE PLANS WITH PANEL SCHEDULES AND | | | LOAD CALCULATIONS. CIRCUITING AND OTHER ITEMS FOR CODE | | | COMPLIANCE CAN NOT BE VERIFIED FOR CODE COMPLIANCE AT | | | THIS TIME. | | | 220, 408.4, 240.4, 310.16 ETC | | | FBC 106.1.1, 106.1.2 | | | | | | | | | | | | | | | **IMPORTANT** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED | | | INTO TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
6 |
Status |
P |
Date |
2010-10-12 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2010-10-12 |
Time |
11:29 |
Rev Time |
0.50 |
| Received By |
mgonzale |
Date |
2010-10-12 |
Time |
11:29 |
Sent To |
|
|
| Notes |
| 2010-10-12 11:30:30 | PASSED | | | STAMPED PLANS DATED OCT 12,2010 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
5 |
Status |
P |
Date |
2010-09-23 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2010-09-23 |
Time |
11:05 |
Rev Time |
1.00 |
| Received By |
mgonzale |
Date |
2010-09-23 |
Time |
11:05 |
Sent To |
|
|
| Notes |
| 2010-09-23 11:05:58 | PASSED: | | | | | | CONTRACTOR HAS COMPLIED WITH ALL REQUIREMENTS FOR | | | PERMIT CLOSE-OUT AT ENGINEERING SERVICES DEPARTMENT. | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
4 |
Status |
P |
Date |
2010-09-23 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2010-09-23 |
Time |
11:02 |
Rev Time |
1.00 |
| Received By |
mgonzale |
Date |
2010-09-23 |
Time |
11:02 |
Sent To |
|
|
| Notes |
| 2010-09-23 11:03:35 | PASSED: | | | | | | CONTRACTOR HAS COMPLIED WITH ALL REQUIREMENTS FOR | | | PERMIT CLOSE-OUT AT ENGINEERING SERVICES DEPARTMENT. | | | | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
P |
Date |
2010-04-12 |
|
|
Cont ID |
|
| Sent By |
dlauderm |
Date |
2010-04-12 |
Time |
10:56 |
Rev Time |
1.00 |
| Received By |
dlauderm |
Date |
2010-04-12 |
Time |
10:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2009-01-26 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2009-01-26 |
Time |
10:40 |
Rev Time |
1.00 |
| Received By |
mgonzale |
Date |
2009-01-26 |
Time |
10:39 |
Sent To |
ENG |
|
| Notes |
| 2010-04-12 10:54:57 | DEAN LAUDERMILK | | | PASSED (RESTAMP) |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2008-11-20 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2008-11-20 |
Time |
15:05 |
Rev Time |
1.00 |
| Received By |
mgonzale |
Date |
2008-11-20 |
Time |
14:49 |
Sent To |
ENG |
|
| Notes |
| 2008-11-20 15:04:52 | - FAILED - | | | | | | WATER AND SEWER ARE IN THE PBC UTILITIES AREA; HOWEVER, | | | TRASH PICK-UP AND STORM-WATER CHARGES WILL APPLY BESD | | | ON PERVIOUS AND IMPERVIOUS. | | | MUST SUBMIT PLANS TO CWPB ENGINEERING THE FOLLOWING | | | COMMENTS APPLY: | | | | | | COMMENTS CONCERNING POLLUTION CONTROL: | | | CODE OF ORDINANCES, CITY OF WEST PALM BEACH, FLORIDA, | | | CODIFIED THROUGH ORD. NO. 4183-08, ADOPTED SEPT. 22, | | | 2008. (SUPPLEMENT NO. 18), CHAPTER 90 UTILITIES, | | | ARTICLE V. STORMWATER POLLUTION PREVENTION | | | SEC. 90-203. PROHIBITED DISCHARGES; ILLICIT | | | CONNECTIONS. | | | (A) GENERAL PROHIBITION. EXCEPT AS PROVIDED IN SECTION | | | 90-205, AND EXCEPT PURSUANT TO A VALID NPDES | | | PERMIT, IT SHALL BE UNLAWFUL FOR ANY PERSON TO | | | DIRECTLY OR INDIRECTLY DEPOSIT, DISCHARGE, SPILL, OR | | | DUMP INTO | | | ANY OF THE PUBLIC WATERS OR MUNICIPAL SEPARATE STORM | | | SEWER SYSTEM WITHIN THE CITY, ANY SUBSTANCE OTHER | | | THAN THAT COMPOSED ENTIRELY OF STORMWATER. | | | PER; CODE OF ORDINANCES, CITY OF WEST PALM BEACH, | | | FLORIDA, CODIFIED THROUGH ORD. NO. 4183-08, ADOPTED | | | SEPT. 22, 2008. (SUPPLEMENT NO. 18), CHAPTER 90 | | | UTILITIES, ARTICLE V. STORMWATER POLLUTION PREVENTION, | | | SEC. 90-203. PROHIBITED DISCHARGES; ILLICIT | | | CONNECTIONS. (A) GENERAL PROHIBITION. EXCEPT AS | | | PROVIDED IN SECTION 90-205, AND EXCEPT PURSUANT TO A | | | VALID NPDES PERMIT, IT SHALL BE UNLAWFUL FOR ANY PERSON | | | TO DIRECTLY OR INDIRECTLY DEPOSIT, DISCHARGE, SPILL, OR | | | DUMP INTO ANY OF THE PUBLIC WATERS OR MUNICIPAL | | | SEPARATE STORM SEWER SYSTEM WITHIN THE CITY, ANY | | | SUBSTANCE OTHER THAN THAT COMPOSED ENTIRELY OF | | | STORMWATER. SUPPLY A POLLUTION CONTROL PLAN WITH A | | | MINIMUM OF THE FOLLOWING INFORMATION; | | | A) SILT FENCE NEEDS TO BE INSTALLED AROUND ANY AREAS TO | | | BE DISTURBED. SHOW WHERE SILT SCREENS WILL BE INSTALLED | | | B) FILTER FABRIC IS REQUIRED UNDER THE CATCH BASIN | | | GRATES WITH ROCK BAGS AT ANY CURBED INLET ON-SITE TO | | | STOP SOLIDS FROM ENTERING THE SYSTEM. SHOW THE | | | PROTECTION OF ALL ON-SITE CATCH BASINS, SHOW PROTECTION | | | OF ALL OFF-SITE CATCH BASINS, INCLUDE DETAILS AS TO THE | | | TYPE OF PROTECTION USED ON AND OFF-SITE FOR THE CATCH | | | BASINS, SUCH AS FILTER FABRIC IS REQUIRED UNDER THE | | | CATCH BASIN GRATES WITH ROCK BAGS AT ANY CURBED INLET | | | TO STOP SOLIDS FROM ENTER THE SYSTEM. | | | C) ADD TURBIDITY BARRIER AT THE OUTFALLS AND ALONG THE | | | FULL WIDTH OF THE PROJECT, SHOW WHERE SILT SCREENS WILL | | | BE INSTALLED, HOW THEY WILL BE TIED DOWN AND | | | MAINTAINED. | | | D) SHOW HOW SITE DIRT WILL NOT BE TRACKED INTO THE | | | ROADS. | | | E) DETAIL HOW AND WHEN ANY CLEAN-UP WILL BE PREFORMED. | | | | | | | | | | | | | | | _______________________________________________________ | | | __________________________________ | | | CODE OF ORDINANCES, CITY OF WEST PALM BEACH, FLORIDA, | | | CODIFIED THROUGH ORD. NO. 4183-08, ADOPTED SEPT. 22, | | | 2008. (SUPPLEMENT NO. 18), CHAPTER 94 ZONING AND LAND | | | DEVELOPMENT REGULATIONS | | | ARTICLE XIV. LANDSCAPING, LAND CLEARING, AND TREE | | | PROTECTION | | | SEC. 94-450. VACANT LOT AND CONSTRUCTION SITE | | | MAINTENANCE. | | | (A) INTENT. THE INTENT OF THIS SECTION IS TO MINIMIZE | | | THE DETRIMENTAL HEALTH, SAFETY, GENERAL WELFARE AND | | | IMPACTS OF VACANT | | | LOTS AND CONSTRUCTION ACTIVITIES ON THE RESIDENTS OF | | | THE CITY OF WEST PALM BEACH; TO ENSURE THAT EACH VACANT | | | LOT AND | | | CONSTRUCTION SITE IS MAINTAINED, AND EACH CONSTRUCTION | | | ACTIVITY IS CONDUCTED IN SUCH A MANNER SO AS TO AVOID | | | UNNECESSARY INCONVENIENCE AND ANNOYANCE TO THE GENERAL | | | PUBLIC AND THE OCCUPANTS OF THE NEIGHBORING PROPERTIES; | | | AND TO REQUIRE MAINTENANCE PRACTICES THAT WILL REDUCE | | | THE AMOUNT OF SEDIMENT AND OTHER POLLUTANTS LEAVING | | | CONSTRUCTION SITES DURING LAND DEVELOPMENT OR LAND | | | DISTURBING CONSTRUCTION ACTIVITIES. | | | _______________________________________________________ | | | __________________________________ | | | | | | - NO POLLUTION CONTROL PLAN SUBMITTED OR SUBMITTED WITH | | | OUT ENGINEERING SERVICES DEPARTMENT APPROVED STAMP. | | | -SUPPLY A POLLUTION CONTROL PLAN WITH A MINIMUM OF THE | | | FOLLOWING INFORMATION; | | | A) SILT FENCE NEEDS TO BE INSTALLED AROUND ANY AREAS TO | | | BE DISTURBED. SHOW WHERE SILT SCREENS WILL BE INSTALLED | | | B) FILTER FABRIC IS REQUIRED UNDER THE CATCH BASIN | | | GRATES WITH ROCK BAGS AT ANY CURBED INLET ON-SITE TO | | | STOP SOLIDS FROM ENTERING THE SYSTEM. SHOW THE | | | PROTECTION OF ALL ON-SITE CATCH BASINS, SHOW PROTECTION | | | OF ALL OFF-SITE CATCH BASINS, INCLUDE DETAILS AS TO THE | | | TYPE OF PROTECTION USED ON AND OFF-SITE FOR THE CATCH | | | BASINS, SUCH AS FILTER FABRIC IS REQUIRED UNDER THE | | | CATCH BASIN GRATES WITH ROCK BAGS AT ANY CURBED INLET | | | TO STOP SOLIDS FROM ENTER THE SYSTEM. | | | C) ADD TURBIDITY BARRIER AT THE OUTFALLS AND ALONG THE | | | FULL WIDTH OF THE PROJECT, SHOW WHERE SILT SCREENS WILL | | | BE INSTALLED, HOW THEY WILL BE TIED DOWN AND | | | MAINTAINED. | | | D) SHOW HOW SITE DIRT WILL NOT BE TRACKED INTO THE | | | ROADS | | | E) DETAIL HOW AND WHEN ANY CLEAN-UP WILL BE PREFORMED. | | | | | | | | | | | | | | | | | | | | | | | | _______________________________________________________ | | | __________________________________ | | | COMMENTS CONCERNING STORMWATER SYSTEM: | | | _______________________________________________________ | | | __________________________________ | | | - NO STORMWATER SYSTEM PLAN SUBMITTED OR SUBMITTED WITH | | | OUT ENGINEERING SERVICES DEPARTMENT APPROVED STAMP. | | | | | | _______________________________________________________ | | | __________________________________ | | | WATER: EVEN THOUGH WATER UTILITY IS SERVED BY PALM | | | BEACH COUNTY THE FIRE HYDRANTS MUST BE TO CITY SPEC. | | | _______________________________________________________ | | | __________________________________ | | | COMMENTS CONCERNING SANITARY SYSTEM: | | | _______________________________________________________ | | | _________________________________ | | | | | | COMMENTS CONCERNING LIGHTING: | | | _______________________________________________________ | | | __________________________________ | | | - NO SITE LIGHTING PLAN SUBMITTED OR SUBMITTED WITH OUT | | | ENGINEERING SERVICES DEPARTMENT APPROVED STAMP. | | | | | | _______________________________________________________ | | | __________________________________ | | | COMMENTS CONCERNING LANDSCAPING: | | | _______________________________________________________ | | | __________________________________ | | | - NO LANDSCAPING PLAN SUBMITTED OR SUBMITTED WITH OUT | | | ENGINEERING SERVICES DEPARTMENT APPROVED STAMP. | | | | | | _______________________________________________________ | | | ___________________________________ | | | COMMENTS CONCERNING SURVEY ISSUES: | | | PER; CODE OF ORDINANCES, CITY OF WEST PALM BEACH, | | | FLORIDA, CODIFIED THROUGH ORD. NO. 4183-08, ADOPTED | | | SEPT. 22, 2008. (SUPPLEMENT NO. 18), CHAPTER 78 | | | STREETS, SIDEWALKS AND PUBLIC PLACES, ARTICLE I. IN | | | GENERAL, SECTION 78-9. CITY DATUM OR PLANE OF | | | REFERENCE. | | | (A) THE CITY DATUM OR OFFICIAL CITY BASE OR PLANE OF | | | REFERENCE FOR ELEVATIONS IN THE CITY IS HEREBY FIXED AS | | | THE NATIONAL GEODETIC VERTICAL DATUM OF 1929 (NGVD-29), | | | AS ESTABLISHED BY THE UNITED STATES COAST AND GEODETIC | | | SURVEY. | | | (B) ALL OFFICIAL ELEVATIONS, INCLUDING BUT NOT | | | RESTRICTED TO SIDEWALK, STREET AND SEWER GRADES, | | | HEREAFTER ESTABLISHED IN THE CITY SHALL BE DESCRIBED | | | WITH REFERENCE TO THEIR ELEVATIONS, AS COMPARED WITH | | | THE OFFICIAL CITY DATUM IN FEET AND DECIMALS OF A FOOT. | | | NO GRADE OR OFFICIAL ELEVATION SHALL BE ESTABLISHED | | | OTHER THAN IN THE MANNER PRESCRIBED IN THIS SECTION. | | | PLEASE USE THIS DATUM AND CALL IT OUT ON THE PLAN | | | SHEETS AS A NOTE. | | | | | | _______________________________________________________ | | | __________________________________ | | | COMMENTS CONCERNING SIDEWALKS AND DRIVEWAY APPROACHES | | | _______________________________________________________ | | | __________________________________ | | | -DRIVEWAY APPROACH AND OR SIDEWALK PLAN NEEDS TO BE | | | APPROVED BY THE ROW PERMIT REVIEWER AT THE TRAFFIC | | | ENGINEERING OFFICE PRIOR TO BEING SUBMITTED TO | | | CONSTRUCTION SERVICES. | | | FYI - OKEECHOBE BLVD IS FDOT ROADWAY. | | | - NO SIDEWALK OR DRIVEWAY APPROACH PLAN SUBMITTED OR | | | SUBMITTED WITH OUT ENGINEERING SERVICES DEPARTMENT | | | APPROVED STAMP. PRIOR TO SUBMITTING ROW PERMIT ASK THE | | | RECEPTIONIST TO FAX IT TO YOU OR STOP BY AND PICK UP A | | | COPY. | | | CONTACT THE RIGHT-OF-WAY REVIEWER, WINDEL PALMER, | | | PROJECT COORDINATOR, THE TRAFFIC ENGINEERS OFFICE AT: | | | 1000 ? 45TH STREET, SUITE 15 | | | WEST PALM BEACH, FL 33407 | | | TELEPHONE: (561)494-1041 | | | FAX: (561) 494-1069 | | | | | | FORM CAN BE DOWNLOADED VIA WEB: | | | HTTP://WWW.CITYOFWPB.ORG/ENGINEERING/ENG_INFO.HTM#RIGHT | | | OFWAY | | | | | | _______________________________________________________ | | | __________________________________ | | | COMMENTS CONCERNING STREETS, SIGNAGE, ADA,: | | | _______________________________________________________ | | | __________________________________ | | | - NO STREET, CURB, ADA PLAN SUBMITTED OR SUBMITTED WITH | | | OUT ENGINEERING SERVICES DEPARTMENT APPROVED STAMP. | | | _______________________________________________________ | | | __________________________________ | | | COMMENTS CONCERNING DUMPSTERS AND ENCLOSURES: | | | _______________________________________________________ | | | __________________________________ | | | - ENCLOSURE DETAIL NOT SUBMITTED OR SUBMITTED WITH | | | NON-STANDARD DETAIL OR WITH OUT ENGINEERING SERVICES | | | DEPARTMENT APPROVED STAMP. | | | DETAIL MUST MATCH WHAT IS TO BE PERMITTED. IF THE CITY | | | DETAIL IS USED THEN A WOOD ENCLOSURE WILL NEED TO BE | | | BUILT. IF CHAIN LINK OR A CONCRETE WALL ARE TO BE USED | | | THEN SUBMIT A DETAIL FOR ONE OF THEM. | | | | | | MANUEL J GONZALEZ, PROJECT COORDINATOR (561) 494-1040 | | | LOCATION ADDRESS: | | | CITY OF WEST PALM BEACH | | | ENGINEERING SERVICES DEPARTMENT | | | 1000 - 45TH STREET, SUITE 15 | | | WEST PALM BEACH FL 33407 | | | CITY'S WEB SITEHAS ALL OUR REFERENCE MATERIAL YOU NEED | | | TO COMPLY: | | | FEEL FREE TO SEE THE LINKS BELOW: | | | WWW.CITYOFWPB.ORG | | | | | | MAILING ADDRESS: | | | CITY OF WEST PALM BEACH | | | ENGINEERING SERVICES DEPARTMENT | | | P.O. BOX 3506 | | | WEST PALM BEACH FL 33401 | | | TELEPHONE: | | | 45TH STREET OFFICE : 561-494-1040 | | | 45TH DIRECT: 561-494-1085 | | | FAX: 561-494-1117 | | | CITY HALL OFFICE: (561) 805-6723 | | | CITY HALL DIRECT: (561) 805-6327 | | | CITY HALL FAX: (561) 805-6731 OR 805-6676 | | | NEXTEL: 561-644-7301 | | | NEXTEL DIRECT CONNECT: 159*28165*38 | | | EMERGENCIES: | | | CENTRAL OPERATIONS CENTER (DISPATCH) 561-822-2210 | | | E-MAIL: | | | [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
5 |
Status |
P |
Date |
2010-03-26 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2010-03-26 |
Time |
11:15 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2010-03-26 |
Time |
10:53 |
Sent To |
|
|
| Notes |
| 2010-03-27 14:06:58 | *****APPROVED**** | | | | | | PLAN SHEETS A1, A2, A3, A-14, AND FD-1 WERE STAMPED, | | | INITIALED, AND DATED. | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2010-01-25 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2010-01-25 |
Time |
12:54 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2010-01-21 |
Time |
14:35 |
Sent To |
|
|
| Notes |
| 2010-01-21 14:37:41 | *****APPROVED**** | | | | | | PLAN SHEETS A1, A2, A3, AND A14 WERE STAMPED, | | | INITIALED, AND DATED. | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
F |
Date |
2009-11-11 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2009-11-11 |
Time |
17:27 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2009-11-11 |
Time |
16:52 |
Sent To |
|
|
| Notes |
| 2009-11-11 17:26:00 | *****PARTIAL APPROVAL***** | | | | | | THE APPROPIATE PLAN SHEETS TO BE FIRE-STAMPED WHEN THE | | | FOLLOWING HAVE BEEN SATISFIED: | | | | | | 1. ON SHEET A0, AMEND REFERENCE TO THE 2006 EDITION OF | | | NFPA 101 - LIFE SAFETY CODE AND THE 2004 EDITION OF | | | NFPA 241. | | | | | | 2. ADDRESS THE OTHER PLAN REVIEWERS' COMMENTS | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2009-02-10 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2009-02-10 |
Time |
14:02 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2009-02-10 |
Time |
14:02 |
Sent To |
|
|
| Notes |
| 2009-02-10 14:11:16 | IT APPEARS THAT ALL THE COMMENTS FROM THE FIRST FIRE | | | REVIEW HAVE BEEN ADDRESSED. SINCE THIS SUBMITTAL IS | | | STILL LISTED AS A PLAN REVIEW ONLY, THE REVIEW WILL | | | REMAIN IN FAILED STATUS UNTIL APPLICATION FOR A PERMIT | | | HAS BEEN SUBMITTED FOR REVIEW. | | | | | | NEW COMMENT | | | | | | 1) LIFE SAFETY SHALL COMPLY WITH NFPA 101, 2006 AND THE | | | FLORIDA FIRE PREVENTION CODE, 2007 SINCE DECEMBER 31, | | | 2008. THIS WILL APPLY WHEN THE PLANS ARE SUBMITTED FOR | | | PERMIT REVIEW. IN ADDITION, PLEASE ADD NFPA 241 TO THE | | | CODE DATA. | | | | | | | | | MIKE WENNERGREN, ASST. FIRE MARSHAL | | | FIRE PLAN REVIEW | | | FIRE PREVENTION (561) 804-4756 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2008-11-12 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-11-12 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-11-12 |
Time |
10:42 |
Sent To |
|
|
| Notes |
| 2008-11-12 10:59:20 | ***DENIED*** | | | | | | PLANS HAVE BEEN SUBMITTED FOR PLAN REVIEW AND NOT FOR | | | PERMIT | | | | | | 1) CS SHEET IDENTIFIES ADDRESS AS OKEECHOBEE ROAD. | | | PLEASE CORRECT ADDRESS TO READ OKEECHOBEE BLVD. AND ADD | | | NUMERICAL OF BUILDING. | | | | | | 2) ADDRESS OF PROJECT TO BE PROVIDED IN TITLE BLOCK OF | | | EACH SHEET SUBMITTED. | | | | | | 3) PROVISIONS FOR AFTER NORMAL BUSINESS HOURS ACCESS TO | | | BE ADDRESSED EITH BY KNOX BOX ENTRY SYSTEM OR OTHER | | | APPROVED SECURED MEANS. | | | | | | 4) ADDRESS IS REQUIRED ON BUILDING THAT SHALL BE | | | MINIMUM OF 6" IN HEIGHT, 1" WIDTH AND CONTRASTING WITH | | | BACKGROUND. PLEASE ADD NOTE TO ELEVATIONS ON SHEET A3. | | | | | | 5) MINIMUM 2A-10B,C RATED FIRE EXTINGUISHERS ARE | | | REQUIRED TO BE MOUNTED AT LOCATIONS NOT TO EXCEED | | | MINIMUM 75' TRAVEL DISTANCE REQUIREMENT. | | | | | | 6) INDICATE THE MINIMUM INTERIOR FINISH CLASSIFICATION | | | FOR WALLS AND CEILING PER 101, SEC. 38.3.3.2. | | | | | | 7) DUCT SMOKE DETECTORS SHALL BE TIED INTO THE BUILDING | | | FIRE ALARM SYSTEM WHEN APPLICABLE. IF NO FIRE ALARM | | | SYSTEM IS PROVIDED, AUDIBLE/VISUAL APPLIANCES ARE STILL | | | REQUIRED FOR LOCAL OCCUPANT NOTIFICATION. | | | | | | 8) ALL EXIT DOORS SHALL COMPLY WITH 101, SEC. 7.2.1.5 | | | LOCKS, LATCHES AND ALARMS. | | | | | | 9) CONSTRUCTION, ALTERATION AND DEMOLITION TO COMPLY | | | WITH NFPA 241. | | | | | | | | | ALTHOUGH NOT A REQUIREMENT, A RESPONSE LETTER | | | INDICATING HOW AND WHERE ON EACH SHEET EACH COMMENT WAS | | | ADDRESSED WOULD HELP TO EXPEDITE THE PLAN REVIEW | | | PROCESS. | | | | | | | | | MIKE WENNERGREN, ASST. FIRE MARSHAL | | | FIRE PLAN REVIEW | | | FIRE PREVENTION (561) 804-4756 | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2010-03-16 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2010-03-09 |
Time |
08:17 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2010-03-09 |
Time |
08:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2010-01-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-01-05 |
Time |
15:15 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-01-05 |
Time |
15:15 |
Sent To |
|
|
| Notes |
| 2010-01-05 15:15:51 | ********* EXPEDITED **************** | | | C 33 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2009-10-27 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2009-10-26 |
Time |
13:22 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2009-10-26 |
Time |
13:21 |
Sent To |
|
|
| Notes |
| 2009-10-27 13:28:14 | C--5 | | | ***************** EXPEDITED ******************* |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2009-10-27 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2008-11-20 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2008-10-17 |
Time |
10:05 |
Sent To |
|
|
| Notes |
| 2008-11-20 15:12:38 | | | | | | | | | | | | | | | | | | | | | | PICKUP AREA "R" CONTACTED ANDREA FOR PICK-UP (LEFT | | | MESSAGE IN) | | | | | | MANNY GONZALEZ 561 644-7301 | | | 11/20/08 | | | | | 2008-10-17 10:05:25 | TO "COMM" BD#40 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2010-01-13 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2010-01-13 |
Time |
08:27 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2010-01-13 |
Time |
08:27 |
Sent To |
|
|
| Notes |
| 2010-01-13 08:29:25 | PAID $ 77, 442.16 | | | PR-MU 2009 -22297 |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
4 |
Status |
N |
Date |
2010-01-12 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2010-01-12 |
Time |
11:08 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2010-01-12 |
Time |
11:08 |
Sent To |
|
|
| Notes |
| 2010-01-12 11:27:36 | ***LANDSCAPE REVIEW NOT REQUIRED UNDER THIS PERMIT*** | | | | | | 1.. PLEASE APPLY FOR SEPARATE IRRIGATION AND LANDSCAPE | | | PERMITS. FOR THE LANDSCAPE PERMIT, TWO COPIES OF THE | | | APPROVED LANDSCAPE PLAN AND A CERTIFIED COST ESTIMATE | | | THAT INCLUDES THE TOTAL COST OF ALL LANDSCAPE MATERIALS | | | AND LABOR, BROKEN DOWN INTO UNIT COST SHALL BE | | | SUBMITTED. THE IRRIGATION PERMIT WILL REQUIRED TWO | | | COPIES OF AN IRRIGATION PLAN. | | | | | | 2. ALL UTILITIES, SITE LIGHTING, EASEMENTS AND ANYTHING | | | ELSE THAT MAY IMPACT THE LANDSCAPING SHALL BE SHOWN ON | | | THE LANDSCAPE PLAN. THERE IS AT LEAST ONE CONFLICT | | | BETWEEN A PROPOSED LIGHT POLE AND AN OAK TREE. LIGHT | | | POLES SHALL BE CENTERED BETWEEN THE TREES AND NOT ANY | | | CLOSER THAN TEN TO FIFTEEN FEET FROM A PROPOSED TREE. | | | | | | 3. PURSUANT TO SECTION 94-444 (B), GARBAGE OR TRASH | | | RECEPTACLES, GENERATORS, TANKS, AIR CONDITIONING UNITS | | | AND ALL OTHER MECHANICAL EQUIPMENT SHALL NOT BE | | | PERMITTED UNLESS APPROPRIATE SCREENING IS PROVIDED. ALL | | | OF THESE ITEMS SHALL BE SHOWN ON THE LANDSCAPE PLAN AND | | | THE MANNER IN WHICH THESE ITEMS WILL BE SCREENED. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT | | | KUSSNER @ (561) 822-1462. |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
3 |
Status |
F |
Date |
2009-11-13 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2009-11-13 |
Time |
11:09 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2009-11-13 |
Time |
11:09 |
Sent To |
|
|
| Notes |
| 2009-11-13 11:12:22 | ***LANDSCAPE REVIEW FAILED*** | | | | | | 1. PLEASE SUBMIT TWO (2) COPIES OF APPROVED LANDSCAPE | | | PLAN. | | | | | | 2. SUBMIT A CERTIFIED COST ESTIMATE THAT INCLUDES THE | | | TOTAL COST OF ALL LANDSCAPE MATERIALS AND LABOR, BROKEN | | | DOWN INTO UNIT COST. | | | | | | 3. ADDRESS ALL OTHER ZONING ISSUES. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT | | | KUSSNER @ (561) 822-1462, | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
F |
Date |
2009-02-06 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2009-02-06 |
Time |
08:53 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2009-02-06 |
Time |
08:53 |
Sent To |
|
|
| Notes |
| 2009-02-06 08:55:00 | ***LANDSCAPE REVIEW FAILED*** | | | | | | PLEASE SEE THE 2/5/09 ZONING COMMENTS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT | | | KUSSNER @ (561) 822-1462. |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
2008-10-21 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2008-10-21 |
Time |
12:26 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2008-10-21 |
Time |
12:26 |
Sent To |
|
|
| Notes |
| 2008-10-21 12:29:33 | ***LANDSCAPE REVIEW FAILED*** | | | | | | SUBMIT (2) COPIES OF APPROVED LANDSCAPE PLAN. | | | | | | IF THERE ARE ANY QUESTIONS REGARDING THE LANDSCAPE | | | REVIEW, PLEASE CONTACT ROBERT KUSSNER @ (561) 822-1462. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
P |
Date |
2010-09-09 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2010-09-09 |
Time |
13:31 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2010-09-09 |
Time |
13:26 |
Sent To |
|
|
| Notes |
| 2010-09-09 13:31:13 | REVISED: M0 AND M3 DELTA 10, M1 AND M2 DELTA 11 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2010-03-30 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2010-03-30 |
Time |
10:13 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2010-03-30 |
Time |
09:40 |
Sent To |
|
|
| Notes |
| 2010-03-30 10:21:37 | PASS PROVISO | | | 1) REVISE EQUIPMENT SCHEDULE ON SHEET MO AHU #2 AND HP | | | #2 DO NOT MATCH . REVISE PLAN BE FOR FINAL INSPECTION . | | | 2) PLEASE REFER TO SECTION 301.12 WIND RESISTANCE 2007 | | | FBC (M) | | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2010-01-25 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2010-01-25 |
Time |
15:01 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2010-01-25 |
Time |
15:01 |
Sent To |
|
|
| Notes |
| 2010-01-25 15:03:05 | FBC 2007 CODE FAMILY W/ 2009 SUPPLEMENTS | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | **PROVISO** | | | | | | 1. REVISE EQUIPMENT SCHEDULE TO SHOW HP-1 AND HP-2 | | | ASSOCIATED WITH AHU-1. THIS NUMBERING CONVENTION HAS | | | HP-3 ASSOCIATED WITH AHU-2, ETC. PROPERLY IDENTIFY EACH | | | PIECE OF EQUIPMENT AND THE AREA IT SERVES IN ACCORDANCE | | | WITH FBC-M 304.11. | | | | | | 2. PROVIDE MANUFACTURER'S WIND RESISTANCE DATA SHOWING | | | ALL OUTDOOR APPLIANCES ARE DESIGNED FOR WIND RESISTANCE | | | IN ACCORDANCE WITH FBC-M 301.12. IF SUCH DOCUMENTATION | | | INCLUDES INSTALLATION INSTRUCTIONS, ADJUST DETAILS ON | | | PLANS TO CORRESPOND WITH THE MANUFACTURER'S | | | DOCUMENTATION. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2009-10-30 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-10-30 |
Time |
12:49 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-10-30 |
Time |
12:41 |
Sent To |
|
|
| Notes |
| 2009-10-30 12:49:24 | REVIEW #: 1ST FOR PERMIT | | | ACTION: DENIED | | | | | | FBC 2007 CODE FAMILY W/ 2009 SUPPLEMENTS | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | PLANS HAVE BEEN STAMPED. HOWEVER, THE REVIEW WILL | | | REMAIN IN FAIL STATUS PENDING SUBMISSION OF THE CORRECT | | | ENERGY CODE COMPLIANCE FORM. THE FORM SUBMITTED, FORM | | | 400A-2004R, IS NO LONGER VALID AS OF MARCH 1, 2009. | | | PLEASE SUBMIT A COMPLETED FORM 400A-08 WHICH MATCHES | | | THE SUBMITTED PLANS AND COOLING LOAD CALCULATIONS. THE | | | FOLLOWING PROVISO CONDITIONS ARE MARKED ON THE PLANS: | | | | | | **PROVISO** | | | | | | 1. REVISE EQUIPMENT SCHEDULE TO SHOW HP-1 AND HP-2 | | | ASSOCIATED WITH AHU-1. THIS NUMBERING CONVENTION HAS | | | HP-3 ASSOCIATED WITH AHU-2, ETC. PROPERLY IDENTIFY EACH | | | PIECE OF EQUIPMENT AND THE AREA IT SERVES IN ACCORDANCE | | | WITH FBC-M 304.11. | | | | | | 2. PROVIDE MANUFACTURER'S WIND RESISTANCE DATA SHOWING | | | ALL OUTDOOR APPLIANCES ARE DESIGNED FOR WIND RESISTANCE | | | IN ACCORDANCE WITH FBC-M 301.12. IF SUCH DOCUMENTATION | | | INCLUDES INSTALLATION INSTRUCTIONS, ADJUST DETAILS ON | | | PLANS TO CORRESPOND WITH THE MANUFACTURER'S | | | DOCUMENTATION. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2009-02-21 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-02-21 |
Time |
14:59 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-02-21 |
Time |
14:52 |
Sent To |
PC |
|
| Notes |
| 2009-02-21 14:59:20 | REVIEW #: 2ND **PLAN CHECK ONLY** | | | ACTION: DENIED | | | | | | FBC 2004 CODE FAMILY W/ 2007 SUPPLEMENTS | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | THE FOLLOWING COMMENTS ARE NUMBERED TO CORRESPOND WITH | | | PREVIOUS REVIEW COMMENTS AS WELL AS DESIGNER'S WRITTEN | | | RESPONSES FOR THE PURPOSE OF CONTINUITY. | | | | | | | | | 1) OK | | | | | | 2) PLEASE SUBMIT COOLING LOAD CALCULATIONS, PER 2004 | | | FBC 13-407.1.ABC.1. | | | 2ND REVIEW** COOLING LOAD CALCULATIONS COULD NOT BE | | | LOCATED IN THIS SUBMITTAL. THIS CALCULATION SHALL BE | | | ATTACHED TO THE CODE COMPLIANCE FORM SUBMITTED TO THE | | | BUILDING DEPARTMENT WHEN THE BUILDING IS PERMITTED IN | | | ACCORDANCE WITH FBC-B 13-407.1.ABC.1. | | | | | | 3) OK | | | | | | 4) OK | | | | | | 5) OK | | | | | | 6) OK | | | | | | 7) OK | | | | | | **NOTE** THESE PLANS ARE SUBMITTED FOR PLAN REVIEW ONLY | | | AT THIS TIME. NO PERMIT APPLICATION HAS BEEN SUBMITTED. | | | A PERMIT APPLICATION SUBMITTED AFTER MARCH 1, 2009 WILL | | | BE SUBJECT TO THE REQUIREMENTS OF THE NEW 2007 FLORIDA | | | BUILDING CODE. IF SUBMITTING FOR PERMIT AFTER THIS | | | DATE, PLEASE REVIEW ALL DESIGNS FOR COMPLIANCE WITH THE | | | NEW CODE PRIOR TO SUBMISSION. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2008-10-23 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-10-23 |
Time |
10:54 |
Rev Time |
2.30 |
| Received By |
tgordon |
Date |
2008-10-23 |
Time |
10:54 |
Sent To |
|
|
| Notes |
| 2008-10-23 12:05:28 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | FOR PLAN REVIEW NOT FOR PERMIT. | | | *** DENIED *** | | | | | | 1) ENERGY CALCULATIONS SYSTEM REPORT NEEDS TO LIST EACH | | | SYSTEM INDIVIDUALITY NOT COMBINE THEM TOGETHER, PER | | | 2004 FBC 13-407.2.A. | | | | | | 2) PLEASE SUBMIT COOLING LOAD CALCULATIONS, PER 2004 | | | FBC 13-407.1.ABC.1. | | | | | | 3) A/C SYSTEM HP-1 HP-2 WITH AHU-1 AND CU-1 WITH AC-1 | | | MODEL NUMBERS LISTED ON THE A/C EQUIPMENT SCHEDULE | | | COULD NOT BE FOUND ON THE ARI DIRECTORY WEB-SITE, | | | PLEASE SUBMIT AN ARI CERTIFICATE OR MANUFACTURE SPEC. | | | SHEETS, PER 2004 FBC 13-407.1.ABC.3.1.1. | | | | | | 4) PLAN M0 AIR HANDLER SCHEDULE NOTE STATES ROUTE | | | CONDENSATE PIPE TO FLOOR DRAIN, PLAN M1 SECTION 'A-A' | | | STATES CONDENSATE LINE TO FLOOR DRAIN, AND PLAN M2 | | | CEILING HUNG A/H DETAIL STATES CONDENSATE DRAIN TO MOP | | | SINK. PLEASE REMOVE THESE NOTES FROM THE PLANS AS | | | CONDENSATE WATER MAY NOT DISCHARGE INTO THE CITY'S | | | WASTE WATER FACILITY, PER CITY OF WEST PALM BEACH CITY | | | CODE 90-125 (B) (5). PLEASE SHOW ON PLANS FOR | | | CONDENSATE WATER TO DISCHARGE OUTDOORS TO AN | | | APPROPRIATE LOCATION, PER 2004 FBC/M 307.2.1. | | | | | | 5) AHU-1 AND AHU-2 WILL REQUIRE SMOKE DETECTORS AT THE | | | SUPPLY AND RETURN, PER 2004 FBC 606.2.2 COMMON SUPPLY, | | | RETURN AIR AND SUPPLY AIR SYSTEMS. WHERE MULTIPLE | | | AIR-HANDLING SYSTEMS SHARE COMMON SUPPLY OR RETURN AIR | | | DUCTS OR PLENUMS WITH A COMBINED DESIGN CAPACITY | | | GREATER THAN 2,000 CFM (0.9 M 3 /S), THE RETURN AIR AND | | | SUPPLY AIR SYSTEM SHALL BE PROVIDED WITH SMOKE | | | DETECTORS IN ACCORDANCE WITH SECTION 606.2.1. PLEASE | | | SHOW ON MECHANICAL PLAN. | | | | | | 6) PLEASE ADD A NOTE TO PLAN M1. PER 2004 FBC/M 602.2.1 | | | MATERIALS EXPOSED WITHIN PLENUMS. EXCEPT AS REQUIRED BY | | | SECTIONS 602.2.1.1 THROUGH 602.2.1.5 , MATERIALS | | | EXPOSED WITHIN PLENUMS SHALL BE NONCOMBUSTIBLE OR SHALL | | | HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 25 AND A | | | SMOKE-DEVELOPED INDEX OF NOT MORE THAN 50 WHEN TESTED | | | IN ACCORDANCE WITH ASTM E 84. | | | | | | 7) PLEASE SUBMIT PRODUCT APPROVAL OR AN NOA FOR | | | ENERTECH DC-FL LOUVERS, PER FS 553.842(1) AND FAC RULE | | | 9B-72, 9B-72.005, AND FAC 9B-72.010(31)(G). | | | | | | **PRODUCT APPROVALS SUBMITTED WITH PERMIT APPLICATION | | | AFTER OCTOBER 1, 2003 ARE REQUIRED TO COMPLY WITH THE | | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR INFORMATION PLEASE | | | SEE THE STATE WEBSITE AT WWW.FLORIDABUILDING.ORG. | | | PRODUCTS WITH STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS THE PRODUCT | | | IDENTITY NUMBER FROM THE STATE. IF THE PRODUCT DOES NOT | | | HAVE STATEWIDE APPROVAL, SUBMIT AN APPLICATION FOR | | | LOCAL PRODUCT APPROVAL OR SITE SPECIFIC FORM PER RULE | | | 9B-72. SEE ATTACHMENT. WWW.FLORIDABUILDING.ORG. | | | | | | *** PRODUCT APPROVALS AND NOA'S SHALL BE REVIEWED AND | | | APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO | | | SUBMITTAL FOR JURISDICTIONAL APPROVAL (A SHOP REVIEW | | | STAMP AND SIGNATURE WILL MEET THIS REQUIREMENT). SEE | | | W.P.B. AMEND. 106.3. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2010-04-01 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2010-04-01 |
Time |
15:16 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2010-04-01 |
Time |
15:16 |
Sent To |
|
|
| Notes |
| 2010-04-01 15:17:04 | RE-STAMPED |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2009-10-29 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-10-29 |
Time |
17:54 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-10-29 |
Time |
17:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2009-01-30 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-01-30 |
Time |
17:10 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-01-30 |
Time |
17:10 |
Sent To |
|
|
| Notes |
| 2009-01-30 17:21:45 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 BUILDING | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | CITY WPB MUNICIPAL CODES | | | | | | ****FROM PREVIOUS REVIEW: | | | | | | 1. ALL SHEETS. THE TITLE BLOCKS SHALL INDICATE THE | | | CORRECT ADDRESS WHICH IS 8132 OKEECHOBEE BLVD, NOT JUST | | | OKEECHOBEE ROAD AS SHOWN. SECTION 106.1.1. | | | ****RESPONSE NOTED, COMMENT NOT ADDRESS FOR ALL SHEETS. | | | | | | 2. OK | | | | | | 3. SHT A1 THE SINK IN ROOM 111 SHALL BE ACCESSIBLE. | | | PLEASE SUBMIT A DETAIL SHOWING COMPLIANCE WITH SECTION | | | 11-4.24 WITH ALL SUBSECTIONS. FORWARD APPROACH CLEAR | | | FLOOR SPACE IS REQUIRED AND CABINET DOORS ARE NOT | | | APPROVED IN THE CLEAR FLOOR SPACE. | | | ****RESPONSE NOTED, BUT SHOW COMPLIANCE WITH THE | | | FOLLOWING: | | | A. 11-4.24.5 CLEAR FLOOR SPACE | | | B. 11-4.24.7 FAUCETS | | | | | | 4. OK | | | | | | 5. SHT A8 DETAILS 8 & 10 SHOW COMPLIANCE WITH THE | | | FOLLOWING: | | | ___W/C'S: | | | A. OK | | | ___LAVS: | | | A. OK | | | B. 11-4.19.7 FAUCETS | | | ****RESPONSE NOTED, COMMENT NOT ADDRESSED | | | | | | 6. OK | | | | | | 7. SHT A10 ELEVATION 5. SHOW COMPLIANCE WITH SECTION | | | 11-4.24. (SEE COMMENT 3). | | | ****RESPONSE NOTED, BUT SHOW COMPLIANCE WITH THE | | | FOLLOWING: | | | A. 11-4.24.5 CLEAR FLOOR SPACE | | | B. 11-4.24.7 FAUCETS | | | | | | 8. ALL P, M & E SHEETS. PER FAC 61G15-23.002(1)(2) A | | | PROFESSIONAL ENGINEER SHALL SIGN HIS NAME & AFFIX HIS | | | SEAL TO ALL PLANS. IT APPEARS THAT AN INITIAL HAS BEEN | | | USED IN PLACE OF THE REQUIRED SIGNATURE. IF INDEED THIS | | | IS THE LEGAL SIGNATURE OF THE ENGINEER OF RECORD, THEN | | | A SIGNED, SEALED, DATED, NOTORIZED LETTER INDICATING | | | THE LEGAL SIGNATURE FOR OUR RECORDS SHALL BE SUBMITTED. | | | FS 471.025. | | | ****RESPONSE NOTED, NO ACTION TAKEN. | | | | | | 9. SHT P-1 FD-2 IN THE MECHANICAL ROOM IS NOT APPROVED | | | FOR CONDENSATE DRAINAGE. ARTICLE III SECTION | | | 90-125(B)(5) . PLEASE SUBMIT INFORMATION/RISER SHOWING | | | THE APPROVED DISPOSAL OF THE CONDENSATE. (PLANTED AREA, | | | STORM LINE, DRYWELL ETC.) (MINIMUM 1 FOOT OFF STRUCTURE | | | WALL REQUIRED. 1503.6). | | | ****RESPONSE NOTED, BUT DETAIL ON SHT P0 REQUIRES A | | | RELIEF VENT, (GOOSENECK), TO 6" ABOVE THE GROUND AS THE | | | CONDENSATE EXITS THE BUILDING. | | | | | | 10. OK | | | 11. OK | | | | | | **********NEW COMMENT********** | | | | | | 1B. SHT A8 DETAILS 8 & 9. SUBMIT DETAILS FOR THE 12 | | | INCH OPEN SPACE ABOVE THE GRAB BARS INDICATED AS | | | "REQUIRED FOR ELBOW ROOM". INDICATE WHAT REQUIRES THE | | | ELBOW ROOM. PER SECTION 11-4.26.2 THE SPACE BEHIND THE | | | GRAB BARS SHALL BE 1-1/2". ALSO SEE FIGURE 11-39D. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2008-11-03 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-11-03 |
Time |
14:12 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-11-03 |
Time |
14:12 |
Sent To |
|
|
| Notes |
| 2008-11-03 14:53:15 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 BUILDING | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | CITY WPB MUNICIPAL CODES | | | | | | 1. ALL SHEETS. THE TITLE BLOCKS SHALL INDICATE THE | | | CORRECT ADDRESS WHICH IS 8132 OKEECHOBEE BLVD, NOT JUST | | | OKEECHOBEE ROAD AS SHOWN. SECTION 106.1.1. | | | | | | 2. SHT AO THE CODE INFORMATION SHALL INCLUDE THE 2005, | | | 2006 & 2007 REVISIONS/AMENDMENTS. SECTION 106.1.1. | | | | | | 3. SHT A1 THE SINK IN ROOM 111 SHALL BE ACCESSIBLE. | | | PLEASE SUBMIT A DETAIL SHOWING COMPLIANCE WITH SECTION | | | 11-4.24 WITH ALL SUBSECTIONS. FORWARD APPROACH CLEAR | | | FLOOR SPACE IS REQUIRED AND CABINET DOORS ARE NOT | | | APPROVED IN THE CLEAR FLOOR SPACE. | | | | | | 4. SHTS A3 & A4.1 INDICATE THE SIZE OF THE GUTTERS AND | | | DOWNSPOUTS. TABLES 1106.3 & 1106.6. | | | | | | 5. SHT A8 DETAILS 8 & 10 SHOW COMPLIANCE WITH THE | | | FOLLOWING: | | | ___W/C'S: | | | A. 11-4.16.5 FLUSH CONTROLS (SHOWN ON WALL SIDE). | | | ___LAVS: | | | A. 11-4.19.2 CLEARANCES | | | B. 11-4.19.7 FAUCETS | | | | | | 6. SHT A8 DETAILS 8 & 9. PER SECTION 1210.2 WALLS | | | WITHIN 2 FEET OF URINALS AND WATER CLOSETS SHALL HAVE A | | | SMOOTH, HARD, NONABSORBENT SURFACE UP TO 4 FEET. 3 FT 4 | | | INCHES IS SHOWN. | | | | | | 7. SHT A10 ELEVATION 5. SHOW COMPLIANCE WITH SECTION | | | 11-4.24. (SEE COMMENT 3). | | | | | | 8. ALL P, M & E SHEETS. PER FAC 61G15-23.002(1)(2) A | | | PROFESSIONAL ENGINEER SHALL SIGN HIS NAME & AFFIX HIS | | | SEAL TO ALL PLANS. IT APPEARS THAT AN INITIAL HAS BEEN | | | USED IN PLACE OF THE REQUIRED SIGNATURE. IF INDEED THIS | | | IS THE LEGAL SIGNATURE OF THE ENGINEER OF RECORD, THEN | | | A SIGNED, SEALED, DATED, NOTORIZED LETTER INDICATING | | | THE LEGAL SIGNATURE FOR OUR RECORDS SHALL BE SUBMITTED. | | | FS 471.025. | | | | | | 9. SHT P-1 FD-2 IN THE MECHANICAL ROOM IS NOT APPROVED | | | FOR CONDENSATE DRAINAGE. ARTICLE III SECTION | | | 90-125(B)(5) . PLEASE SUBMIT INFORMATION/RISER SHOWING | | | THE APPROVED DISPOSAL OF THE CONDENSATE. (PLANTED AREA, | | | STORM LINE, DRYWELL ETC.) (MINIMUM 1 FOOT OFF STRUCTURE | | | WALL REQUIRED. 1503.6). | | | | | | 10. SHT P1 PLUMBING FLOOR PLAN DOES NOT SHOW THE RISER | | | AND PIPING FOR THE LAVS AS INDICATED ON THE WASTE & | | | VENT RISER DIAGRAM. PLEASE SHOW THE SANT. PIPING AND | | | RISER FOR THE LAVS ON THE FLOOR PLAN TO CORRELATE WITH | | | THE RISER DIAGRAM. SECTIONS 106.1.1 & 701.1. | | | | | | 11. SHT P2 THE WATER HAMMER ARRESTORS SHALL BE | | | INSTALLED NEAR THE FIXTURES IN AN EFFECTIVE RANGE NOT | | | IN THE CEILING AS SHOWN. PDI-WH 201. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
5 |
Status |
P |
Date |
2010-03-19 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2010-03-19 |
Time |
17:13 |
Rev Time |
2.50 |
| Received By |
eschneid |
Date |
2010-03-19 |
Time |
17:13 |
Sent To |
|
|
| Notes |
| 2010-03-19 17:22:53 | PASSED W/PROVISOS | | | | | | 1) PROVISO - THE SUBMITTED SITE PLAN DOES NOT SHOW A | | | SCOPE OF WORK FOR ALL OF TRACT B, SPECIFICALLY PARKING | | | AND LANDSCAPE ISLAND IN THE SOUTHEAST CORNER OF THE | | | TRACT. A PROVISO NOTE HAS BEEN ADDED TO THE PLANS | | | STATING THAT THE LANDSCAPE ISLAND AND CURBING SHALL BE | | | INSTALLED AND THE PARKING STRIPED. IT IS SHOWN ON THE | | | LANDSCAPE PLAN UNDER SEPARATE PERMIT. | | | | | | 2) PROVISO - THE REQUIRED BICYCLE RACK IS NOT SHOWN ON | | | THE PLANS. A PROVISO NOTE HAS BEEN ADDED TO THE PLANS | | | SHOWING THE REQUIRED BICYCLE RACK LOCATION. | | | | | | 3) PROVISO - THE LIGHTING UNDER THE DRIVE-THRU CANOPY | | | SHALL BE FLUSH MOUNTED OR RECESSED. THE ELEVATION PLANS | | | SEEM TO SUPPORT THIS, BUT NOWHERE IS IT CLEARLY | | | ILLUSTRATED. A PROVISO NOTE HAS BEEN ADDED TO THE PLANS | | | TO ANNOTATE THIS REQUIREMENT. STAFF RECOGNIZES THAT CUT | | | SHEETS WERE PROVIDED SHOWING FLUSH MOUNTED LIGHTS. | | | | | | 4) PROVISO - THE APPROVED CONSTRUCTION SITE SECURITY | | | AND MANAGEMENT PLAN SHALL BE KEPT ON SITE AND ADHERED | | | TO DURING THE ENTIRE CONSTRUCTION PROCESS (ZONING | | | STAMPED COPY INCLUDED IN THE NOTEBOOK). | | | | | | 4) PLEASE NOTE THAT ALL SIGNAGE REQUIRES A SEPARATE | | | SIGN PERMIT. | | | | | | 5) REMEMBER THAT PER THE APPROVED SEDONA COMMONS CPD | | | (ORDINANCE NO. 4166-08), THE EBR TURN LANE ONTO THE | | | "RIGHT-IN/RIGHT-OUT ONLY" PROJECT ACCESS DRIVEWAY ON | | | OKEECHOBEE BOULEVARD, THE ACCESS POINT AND DRIVEWAY ON | | | OKEECHOBEE BOULEVARD, THE REMOVAL OF THE EXISTING | | | ACCESS POINT AND DRIVEWAY ON OKEECHOBEE BOULEVARD, AND | | | ALL OTHER SITE IMPROVEMENTS ON TRACT "A" AS SHOWN ON | | | THE SITE PLAN, SHALL BE COMPLETED PRIOR TO OBTAINING A | | | CERTIFICATE OF OCCUPANCY ("CO") FOR THE FIRST BUILDING | | | IN THE SEDONA COMMONS CPD. THE BANK WILL NOT RECEIVE A | | | CO UNTIL THIS IS COMPLETED. THE DRIVEWAY CONNECTION | | | WILL REQUIRE A FDOT OR PALM BEACH COUNTY FINAL APPROVAL | | | (PICTURES PROVIDED BUT NO OFFICIAL APPROVAL) AND THE | | | WORK ON TRACT A WILL REQUIRE A FINAL INSPECTION PASS | | | FROM THE CITY OF WEST PALM BEACH. | | | | | | COMMENTS/QUESTIONS, CONTACT ERIC SCHNEIDER, PRINCIPAL | | | PLANNER, AT 822-1446. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
F |
Date |
2010-01-11 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2010-01-11 |
Time |
16:55 |
Rev Time |
1.50 |
| Received By |
eschneid |
Date |
2010-01-11 |
Time |
16:55 |
Sent To |
|
|
| Notes |
| 2010-01-11 17:56:10 | FAILED | | | | | | PROVIDE RESPONSES IN WRITING. | | | | | | 1. REVISED COMMENT (PARTIALLY ADDRESSED) - THE | | | CONSTRUCTION SITE SECURITY AND MANAGEMENT PLAN APPROVED | | | BY THE CITY'S POLICE DEPARTMENT CRIME PREVENTION | | | THROUGH ENVIRONMENTAL DESIGN ("CPTED") OFFICIAL ON | | | NOVEMBER 12, 2009, SHALL BE FOLLOWED. THE PLAN SHALL BE | | | SUBMITTED WITH THE PERMIT APPLICATION. | | | | | | 2. REVISED COMMENT (PARTIALLY ADDRESSED) - THE SITE | | | PLAN PROVIDED WITH THE PHOTOMETRIC PLAN IS CONSISTENT | | | WITH THE APPROVED SITE PLAN. THE NEW LIGHT POLE ALONG | | | THE NORTH PROPERTY LINE SHALL BE SHIFTED TO THE WEST | | | AND CENTERED IN THE OPEN AREA BETWEEN THE BUFFER TREES. | | | UPON RESUBMITTAL OF THE PHOTOMETRIC PLAN, THE FOOT | | | CANDLE LEVELS SHALL BE EXTENDED TO THE NORTH AND EAST | | | PROPERTY LINES. THE PREVIOUS PLAN THAT SHOWED THESE | | | CALCULATIONS DOES NOT MATCH NEW LIGHT POST LOCATIONS. | | | NOTE: THE LIGHT LEVEL MAY NOT EXCEED ONE FOOT CANDLE AT | | | THE PROPERTY LINES OF THE SEDONA COMMONS DEVELOPMENT. | | | | | | 3. REPEAT COMMENT - A LANDSCAPE PERMIT IS REQUIRED | | | PRIOR TO ZONING APPROVAL OF THE BUILDING PERMIT. A COST | | | ESTIMATE OF THE LANDSCAPE WORK SHALL BE INCLUDED WITH | | | THE LANDSCAPE PERMIT. | | | | | | 4. REPEAT COMMENT - THE ADDRESS AND THE PARCEL CONTROL | | | NUMBER FOR THIS PERMIT ARE INCORRECT. THE CORRECT | | | ADDRESS IS 8100 OKEECHOBEE BOULEVARD AND THE PARCEL | | | CONTROL NUMBER IS 74424329300020000. THIS ALSO NEEDS TO | | | BE CORRECTED BY APPLICANT WITH THE CONSTRUCTION | | | SERVICES DEPARTMENT PERMIT CLERKS. | | | | | | 5. REPEAT COMMENT - THE SUBMITTED PERMIT DOES NOT SHOW | | | A SCOPE OF WORK FOR ALL OF TRACT B, SPECIFICALLY | | | PARKING AND LANDSCAPE IN THE SOUTHEAST CORNER OF THE | | | TRACT. | | | | | | 6. REPEAT COMMENT - THE DUMPSTER AREA AND PARKING TO | | | THE NORTHWEST OF THE BUILDING ARE NOT IN TRACT B AND | | | THUS REQUIRE SEPARATE PERMIT APPLICATION SHEETS | | | REFLECTING THE ADDRESS AND PARCEL CONTROL NUMBER OF THE | | | PROJECT SITE. THE SAME PLANS MAY BE USED FOR BOTH | | | APPLICATIONS. | | | | | | 7. NEW COMMENT - THE REQUIRED BICYCLE RACK IS NOT SHOWN | | | ON THE PLANS. | | | | | | 8. PLEASE NOTE THAT ALL SIGNAGE REQUIRES A SEPARATE | | | SIGN PERMIT. | | | | | | 9. PLEASE NOTE THAT IRRIGATION REQUIRES A SEPARATE | | | IRRIGATION PERMIT. | | | | | | 10. REMEMBER THAT PER THE APPROVED SEDONA COMMONS CPD | | | (ORDINANCE NO. 4166-08), THE EBR TURN LANE ONTO THE | | | "RIGHT-IN/RIGHT-OUT ONLY" PROJECT ACCESS DRIVEWAY ON | | | OKEECHOBEE BOULEVARD, THE ACCESS POINT AND DRIVEWAY ON | | | OKEECHOBEE BOULEVARD, THE REMOVAL OF THE EXISTING | | | ACCESS POINT AND DRIVEWAY ON OKEECHOBEE BOULEVARD, AND | | | ALL OTHER SITE IMPROVEMENTS ON TRACT "A" AS SHOWN ON | | | THE SITE PLAN, SHALL BE COMPLETED PRIOR TO OBTAINING A | | | CERTIFICATE OF OCCUPANCY ("CO") FOR THE FIRST BUILDING | | | IN THE SEDONA COMMONS CPD. THE BANK WILL NOT RECEIVE A | | | CO UNTIL THIS IS COMPLETED. THE DRIVEWAY CONTECTION | | | WILL REQUIRE A FDOT OR PLAM BEACH COUNTY FINAL APPROVAL | | | AND THE WORK ON TRACT A WILL REQUIRE A FINAL INSPECTION | | | PASS FROM THE CITY OF WEST PALM BEACH. | | | | | | 11. PLEASE REMEMBER THAT THE SEDONA COMMONS CPD | | | DEVELOPMENT REGULATIONS REQUIRE THAT ALL GROUND AND | | | ROOF MOUNTED AIR CONDITIONING, MECHANICAL EQUIPMENT, | | | SATELLITE DISHES, GENERATORS, ETC., SHALL BE SCREENED | | | FROM VIEW ON ALL SIDES BY A VISUALLY OPAQUE BARRIER | | | CONSISTENT WITH THE COLOR, CHARACTER AND ARCHITECTURAL | | | STYLE OF THE STRUCTURES OR EQUIVALENT LANDSCAPE | | | MATERIAL. THE HEIGHT OF THE OPAQUE BARRIER SHALL BE AS | | | REQUIRED TO PROVIDE AMPLE SCREENING. THE EAST SIDE OF | | | THE A/C PAD DOES NOT APPEAR TO HAVE A WALL OR LANDSCAPE | | | SCREEN AND THE SOUTH LANDSCAPE MAY NOT BE ADEQUATE TO | | | SCREEN THE A/C UNITS. THE A/C PERMIT WILL NOT PASS | | | WITHOUT THE SCREENING. | | | | | | 12. THE LIGHTING UNDER THE DRIVE-THRU CANOPY SHALL BE | | | FLUSH MOUNTED OR RECESSED. THE ELEVATION PLANS SEEM TO | | | SUPPORT THIS, BUT NOWHERE IS IT CLEARLY ILLUSTRATED. | | | | | | COMMENTS/QUESTIONS, CONTACT ERIC SCHNEIDER, PRINCIPAL | | | PLANNER, AT 822-1446. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2009-11-04 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2009-11-04 |
Time |
18:11 |
Rev Time |
1.00 |
| Received By |
eschneid |
Date |
2009-11-04 |
Time |
18:11 |
Sent To |
|
|
| Notes |
| 2009-11-04 18:11:30 | ***FAILED*** | | | | | | 1. REPEAT COMMENT - PLEASE NOTE THAT PER THE APPROVED | | | SEDONA COMMONS CPD, PRIOR TO APPLYING FOR THE FIRST | | | BUILDING PERMIT, INCLUDING SITE PREPARATION, THE | | | APPLICANT SHALL PREPARE A CONSTRUCTION SITE SECURITY | | | AND MANAGEMENT PLAN FOR APPROVAL BY THE CITY'S POLICE | | | DEPARTMENT CRIME PREVENTION THROUGH ENVIRONMENTAL | | | DESIGN ("CPTED") OFFICIAL. NO APPROVED PLAN HAS BEEN | | | SUBMITTED. | | | | | | 2. REPEAT COMMENT - THE SUBMITTED SITE IMPROVEMENT PLAN | | | (PREPARED BY LDI) DOES NOT MATCH THE APPROVED SITE OR | | | LANDSCAPE PLAN PER ORDINANCE NO. 4166-08. | | | DISCREPANCIES: | | | | | | A) LOCATION OF ADA SPACES | | | B) LAYOUT OF PARKING SOUTHEAST OF THE BUILDING | | | C) BUILDING IS A DIFFERENT SIZE AND LOCATION | | | D) WIDTH OF PARKING SPACE NORTHWEST OF THE BUILDING | | | E) LENGTH OF MOST PARKING SPACES | | | F) REMOVAL OF CURBING | | | E) SIDEWALKS AND CROSSWALKS NOT SHOW AS PAVERS | | | F) WIDTH OF FOUNDATION LANDSCAPE PLANTING BED SOUTH AND | | | WEST SIDES OF BUILDING | | | G) WIDTH OF THE LANDSCAPE DIVIDER MEDIAN IN PARKING ROW | | | SOUTH OF BUILDING | | | H) ONE PARKING SPACE HAS BEEN REMOVED. | | | | | | SOME OF THESE DISCREPANCIES MAY BE CORRECTED THROUGH | | | THE APPROVAL OF A MINOR PLANNED DEVELOPMENT AMENDMENT | | | TO THE APPROVED SITE AND LANDSCAPE PLANS FOR THE SEDONA | | | COMMONS COMMERCIAL PLANNED DEVELOPMENT (CPD) - EX. A | | | AND F, BUT OTHERS MAY NOT - EX. E AND H. LDI PLANS | | | SHALL MATCH THE PLANS APPROVED BY ORDINANCE NO. | | | 4166-08. | | | | | | 3. REPEAT COMMENT - THE ADA PARKING DETAIL ON THE LDI | | | PLANS SHALL SHOW THE PARKING LOGO NO GREATER THAN 2 | | | FEET FROM THE OPEN END OF THE PARKING SPACE. NO | | | DIMENSION PROVIDED. | | | | | | 4. REPEAT COMMENT - THE DUMPSTER DETAIL ON THE LDI | | | PLANS SHALL SHOW THAT THE OPENING DIMENSION IS A | | | MINIMUM OF 12'6" WIDE. NO DIMENSION PROVIDED. | | | | | | 5. PLEASE NOTE THAT ALL SIGNAGE REQUIRES A SEPARATE | | | SIGN PERMIT. | | | | | | 6. PLEASE NOTE THAT IRRIGATION REQUIRES A SEPARATE | | | IRRIGATION PERMIT. | | | | | | 7. REPEAT COMMENT - PLEASE NOTE THAT PER THE APPROVED | | | SEDONA COMMONS CPD (ORDINANCE NO. 4166-08), THE EBR | | | TURN LANE ONTO THE "RIGHT-IN/RIGHT-OUT ONLY" PROJECT | | | ACCESS DRIVEWAY ON OKEECHOBEE BOULEVARD, THE ACCESS | | | POINT AND DRIVEWAY ON OKEECHOBEE BOULEVARD, THE REMOVAL | | | OF THE EXISTING ACCESS POINT AND DRIVEWAY ON OKEECHOBEE | | | BOULEVARD, AND ALL OTHER SITE IMPROVEMENTS ON TRACT "A" | | | AS SHOWN ON THE SITE PLAN, SHALL BE COMPLETED PRIOR TO | | | OBTAINING A CERTIFICATE OF OCCUPANCY ("CO") FOR THE | | | FIRST BUILDING IN THE SEDONA COMMONS CPD. UP TO TODAY, | | | THERE IS NO EVIDENCE THAT ANY OF THESE ITEMS HAVE BEEN | | | COMPLETED. NONE OF THIS WORK HAS BEEN COMPLETED. | | | | | | 8. NEW COMMENT - THE BASE MAP FOR THE PHOTOMETRIC PLAN | | | DOES NOT MATCH THE APPROVED SITE AND LANDSCAPE PLANS. | | | THERE APPEARS TO BE AT LEAST ONE CONFLICT WITH A LIGHT | | | POLE AND TREE. | | | | | | 9. NEW COMMENT - NO LANDSCAPE PLAN WAS SUBMITTED WITH | | | THIS PERMIT. PLEASE NOTE THAT A LANDSCAPE SUB-PERMIT IS | | | REQUIRED. A COST ESTIMATE OF THE LANDSCAPE WORK SHALL | | | BE INCLUDED WITH THE LANDSCAPE SUB-PERMIT. | | | | | | 10. NEW COMMENT - THE PARKING DETAILS DO NOT MEET CITY | | | OF WEST PALM BEACH CODE REQUIREMENTS. THE CITY DOES NOT | | | ALLOW SINGLE STRIPING AND THE DIMENSIONS SHOWN ON THE | | | DETAILS SHALL MATCH THE DIMENSIONS ON THE PLANS. NOTE: | | | WHEEL STOPS SHALL BE 2 FEET FROM THE END OF THE PARKING | | | SPACE. | | | | | | 11. NEW COMMENT - THE PARKING SECTIONS SHOW 19.5 FOOT | | | DEEP SPACES, WHICH DO NOT APPEAR ON THE PLANS. | | | | | | 12. NEW COMMENT - SHEETS A0 AND A1 LIST DIFFERING | | | AMOUNTS OF BUILDING SQUARE FOOTAGE. | | | | | | 13. NEW COMMENT - THE ADDRESS AND THE PARCEL CONTROL | | | NUMBER FOR THIS PERMIT ARE INCORRECT. THE CORRECT | | | ADDRESS IS 8100 OKEECHOBEE BOULEVARD AND THE PARCEL | | | CONTROL NUMBER IS 74424329300020000. | | | | | | 14. NEW COMMENT - THE SUBMITTED PERMIT DOES NOT SHOW A | | | SCOPE OF WORK FOR ALL OF TRACT B, SPECIFICALLY PARKING | | | AND LANDSCAPE IN THE SOUTHEAST CORNER OF THE TRACT. | | | | | | 15. NEW COMMENT - THE DUMPSTER AREA, PARKING AND | | | LANDSCAPE TO THE NORTHWEST OF THE BUILDING ARE NOT IN | | | TRACT B AND THUS REQUIRE SEPARATE PERMITS. | | | | | | COMMENTS/QUESTIONS, CONTACT ERIC SCHNEIDER, PRINCIPAL | | | PLANNER, AT 822-1446. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2009-02-05 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2009-02-05 |
Time |
17:25 |
Rev Time |
1.00 |
| Received By |
eschneid |
Date |
2009-02-05 |
Time |
17:25 |
Sent To |
|
|
| Notes |
| 2009-02-05 18:31:55 | ***FAILED*** | | | | | | 1. REPEAT COMMENT - PLEASE NOTE THAT PER THE APPROVED | | | SEDONA COMMONS CPD, PRIOR TO APPLYING FOR THE FIRST | | | BUILDING PERMIT, INCLUDING SITE PREPARATION, THE | | | APPLICANT SHALL PREPARE A CONSTRUCTION SITE SECURITY | | | AND MANAGEMENT PLAN FOR APPROVAL BY THE CITY'S POLICE | | | DEPARTMENT CRIME PREVENTION THROUGH ENVIRONMENTAL | | | DESIGN ("CPTED") OFFICIAL. NO APPROVED PLAN HAS BEEN | | | SUBMITTED. | | | | | | 2. REPEAT COMMENT - THE SUBMITTED SITE IMPROVEMENT PLAN | | | (NONE PREPARED BY LDI) DOES NOT MATCH THE APPROVED SITE | | | OR LANDSCAPE PLAN PER ORDINANCE NO. 4166-08. EXAMPLES | | | OF DISCREPANCIES - LOCATION OF ADA SPACES AND LAYOUT OF | | | PARKING SOUTHEAST OF THE BUILDING. IN THE EVENT THAT | | | ANY CHANGES WILL BE DONE TO THE APPROVED SITE AND | | | LANDSCAPE PLANS, A MINOR AMENDMENT TO THE SEDONA | | | COMMONS COMMERCIAL PLANNED DEVELOPMENT (CPD) IS | | | REQUIRED. OTHERWISE, REVISE THE LDI PLANS. | | | | | | 3. THE ADA PARKING DETAIL ON THE LDI PLANS SHALL SHOW | | | THE PARKING LOGO NO GREATER THAN 2 FEET FROM THE OPEN | | | END OF THE PARKING SPACE. | | | | | | 4. THE DUMPSTER DETAIL ON THE LDI PLANS SHALL SHOW THAT | | | THE OPENING DIMENSION IS A MINIMUM OF 12'6" WIDE. | | | | | | 5. PLEASE NOTE THAT ALL SIGNAGE REQUIRES A SEPARATE | | | SIGN PERMIT. | | | | | | 6. PLEASE NOTE THAT IRRIGATION REQUIRES A SEPARATE | | | IRRIGATION PERMIT. | | | | | | 7. PLEASE NOTE THAT PER THE APPROVED SEDONA COMMONS CPD | | | (ORDINANCE NO. 4166-08), THE EBR TURN LANE ONTO THE | | | "RIGHT-IN/RIGHT-OUT ONLY" PROJECT ACCESS DRIVEWAY ON | | | OKEECHOBEE BOULEVARD, THE ACCESS POINT AND DRIVEWAY ON | | | OKEECHOBEE BOULEVARD, THE REMOVAL OF THE EXISTING | | | ACCESS POINT AND DRIVEWAY ON OKEECHOBEE BOULEVARD, AND | | | ALL OTHER SITE IMPROVEMENTS ON TRACT "A" AS SHOWN ON | | | THE SITE PLAN, SHALL BE COMPLETED PRIOR TO OBTAINING A | | | CERTIFICATE OF OCCUPANCY ("CO") FOR THE FIRST BUILDING | | | IN THE SEDONA COMMONS CPD. UP TO TODAY, THERE IS NO | | | EVIDENCE THAT ANY OF THESE ITEMS HAVE BEEN COMPLETED. | | | | | | 8. PLEASE NOTE THAT THE LIGHTING UNDER THE DRIVE- | | | THROUGH CANOPY SHALL BE FLUSH MOUNTED OR RECESSED. | | | | | | COMMENTS/QUESTIONS, CONTACT ERIC SCHNEIDER, PRINCIPAL | | | PLANNER, AT 822-1435. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2008-10-21 |
|
|
Cont ID |
|
| Sent By |
adavila |
Date |
2008-10-21 |
Time |
15:34 |
Rev Time |
0.00 |
| Received By |
adavila |
Date |
2008-10-21 |
Time |
14:56 |
Sent To |
|
|
| Notes |
| 2008-10-21 15:35:02 | PLANNING AND ZONING DEPARTMENT | | | | | | ***FAILED*** | | | | | | 1. PLEASE NOTE THAT PER THE APPROVED SEDONA COMMONS | | | COMMERCIAL PLANNED DEVELOPMENT ("CPD"), PRIOR TO | | | APPLYING FOR THE FIRST BUILDING PERMIT, INCLUDING SITE | | | PREPARATION, THE APPLICANT SHALL COMPLETE THE | | | FOLLOWING: | | | | | | A) RECORD IN THE PUBLIC RECORDS OF PALM BEACH COUNTY, A | | | DECLARATION OF COVENANTS AND RESTRICTIONS, AND SUBMIT A | | | COPY OF THE NEWLY RECORDED DOCUMENT TO THE PLANNING AND | | | ZONING DEPARTMENT. | | | | | | B) SUBMIT A COPY OF THE RECORDED SEDONA COMMONS CPD | | | PLAT TO THE ENGINEERING SERVICES AND PLANNING AND | | | ZONING DEPARTMENTS. | | | | | | C) PREPARE A CONSTRUCTION SITE SECURITY AND MANAGEMENT | | | PLAN FOR APPROVAL BY THE CITY'S POLICE DEPARTMENT CRIME | | | PREVENTION THROUGH ENVIRONMENTAL DESIGN ("CPTED") | | | OFFICIAL. | | | | | | PLEASE PROVIDE THE STATUS OF THESE ITEMS. A COPY OF THE | | | RECORDED PLAT AND DOCUMENTS SHALL BE SUBMITTED WITH THE | | | BUILDING PERMIT APPLICATION. | | | | | | 2. THE SUBMITTED SITE IMPROVEMENT PLAN DOES NOT MATCH | | | THE APPROVED SITE PLAN PER ORDINANCE NO. 4166-08. | | | PLEASE REVISE. IN THE EVENT THAT ANY CHANGES WILL BE | | | DONE TO THE APPROVED SITE PLAN (I.E. RELOCATION OF | | | HANDICAP PARKING SPACES), A MINOR AMENDMENT TO THE | | | SEDONA COMMONS CPD IS REQUIRED. | | | | | | 3. ALL EXTERIOR SITE WORK, TO INCLUDE THE INSTALLATION | | | OF ANY LANDSCAPING, EXTERIOR LIGHTING, ETC., WITHIN | | | THIS TRACT (TRACT "B") SHALL BE APPROVED WITH THIS | | | PERMIT APPLICATION. PLEASE SUBMIT THE SITE, LANDSCAPE | | | AND PHOTOMETRIC PLANS FOR THIS TRACT. IN THE EVENT THAT | | | THE APPLICANT WISHES TO SUBMIT A SEPARATE APPLICATION | | | FOR ALL EXTERIOR WORK, THE COMPLETE SCOPE OF WORK FOR | | | THIS PERMIT SHALL BE STATED IN THE PLANS. | | | | | | 4. PLEASE NOTE THAT PER THE APPROVED SEDONA COMMONS CPD | | | (ORDINANCE NO. 4166-08), THE EBR TURN LANE ONTO THE | | | "RIGHT-IN/RIGHT-OUT ONLY" PROJECT ACCESS DRIVEWAY ON | | | OKEECHOBEE BOULEVARD, THE ACCESS POINT AND DRIVEWAY ON | | | OKEECHOBEE BOULEVARD, THE REMOVAL OF THE EXISTING | | | ACCESS POINT AND DRIVEWAY ON OKEECHOBEE BOULEVARD, AND | | | ALL OTHER SITE IMPROVEMENTS ON TRACT "A" AS SHOWN ON | | | THE SITE PLAN, SHALL BE COMPLETED PRIOR TO OBTAINING A | | | CERTIFICATE OF OCCUPANCY ("CO") FOR THE FIRST BUILDING | | | IN THE SEDONA COMMONS CPD. UP TO TODAY, THERE IS NO | | | EVIDENCE THAT ANY OF THESE ITEMS HAVE BEEN COMPLETED. | | | | | | COMMENTS/QUESTIONS, CONTACT ANDREINA DAVILA Q. OR ERIC | | | SCHNEIDER, PRINCIPAL PLANNER, AT 822-1435. | | | |
|
|
|
Account Summary | Usage Policy | Privacy Policy