| Plan Review Stops For Permit 08100220 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2009-08-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2009-08-13 |
Time |
10:24 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2009-08-13 |
Time |
10:24 |
Sent To |
|
|
| Notes |
| 2009-08-13 10:25:42 | REVISED ROOFING AND FRENCH DOOR PRODUCT APPROVALS. | | | SUBMITTED TRUSS REPAIR AND MODIFICATION DETAILS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2009-05-18 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2009-04-30 |
Time |
16:09 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2009-04-30 |
Time |
16:09 |
Sent To |
|
|
| Notes |
| 2009-04-30 16:20:30 | 2004 FBC W/2007 REVISIONS | | | | | | DENIED BY BUILDING | | | | | | 1) SUBMIT TWO COPIES OF ENERGY CALCULATIONS FOR THE | | | ADDITION AS REQUIRED BY FBC 13-600. THE PREPARER AND | | | OWNER/AGENT SIGNATURES ARE REQUIRED ON THE FORMS. 2004 | | | FBC 13-103.3 | | | | | | 2) SHOP DRAWINGS FOR THE EXTERIOR BALCONY WILL BE | | | REQUIRED TO BE SUBMITTED FOR APPROVAL PRIOR TO | | | INSTALLATION. FBC 106.1.2* CITY AMENDMENTS | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2009-02-04 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2009-02-04 |
Time |
11:21 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2009-02-04 |
Time |
07:54 |
Sent To |
M |
|
| Notes |
| 2009-02-04 11:21:49 | 2004 FBC W/2007 REVISIONS | | | TWO STORY ADDITION | | | | | | DENIED BY BUILDING | | | | | | 1) BEFORE A PERMIT TO CONSTRUCT CAN BE | | | ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE PLANS MUST BE | | | STAMPED AND THE RECEIPT ATTACHED TO THE | | | APPLICATION. 233-5025 | | | | | | 2) COMMENT WAS ADDRESSED. | | | | | | 3) SUBMIT TWO COPIES OF ENERGY CALCULATIONS FOR THE | | | ADDITION AS REQUIRED BY FBC 13-600. THE PREPARER AND | | | OWNER/AGENT SIGNATURES ARE REQUIRED ON THE FORMS. | | | | | | 4) COMMENT WAS ADDRESSED. | | | | | | 5) COMMENT WAS ADDRESSED. | | | | | | 6) COMMENT WAS ADDRESSED. | | | | | | 7) COMMENT WAS ADDRESSED. | | | | | | 8) COMMENT WAS ADDRESSED. | | | | | | 9) COMMENT WAS ADDRESSED. | | | | | | 10) COMMENT WAS ADDRESSED. | | | | | | 11) COMMENT WAS ADDRESSED. | | | | | | 12) SUBMIT TWO COPIES OF PRODUCT APPROVALS FOR THE | | | GLASS BLOCK, EXTERIOR FRENCH DOORS AND STRUCTURAL | | | WINDOW MULLIONS AS REQUIRED BY FAC RULE 9B-72. NOTE: IF | | | PRODUCTS ARE NOT LARGE MISSILE IMPACT RATED, THEN | | | PRODUCT APPROVALS, INSTALLATION SCHEDULES AND KEY PLANS | | | FOR STORM PANELS WILL BE REQUIRED. FBC R301.2.1.2 NOTE: | | | PRODUCT APPROVALS ARE REQUIRED TO BE APPROVED IN | | | WRITING DESIGNER OF RECORD. | | | | | | 13) SHOP DRAWINGS FOR THE EXTERIOR BALCONY WILL BE | | | REQUIRED TO BE SUBMITTED FOR APPROVAL BEFORE THEY ARE | | | INSTALLED. FBC 106.1.2* CITY AMENDMENTS | | | | | | NOTE: THE NOTICE OF COMMENCEMENT HAS EXPIRED. IT WILL | | | NEED TO BE RE-RECORDED BEFORE THE FIRST INSPECTION. FS | | | 713 | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-10-23 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2008-10-23 |
Time |
10:22 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2008-10-23 |
Time |
07:52 |
Sent To |
E |
|
| Notes |
| 2008-10-23 10:22:42 | 2004 FBC W/2007 REVISIONS | | | TWO STORY ADDITION | | | | | | DENIED BY BUILDING | | | | | | 1) BEFORE A PERMIT TO CONSTRUCT CAN BE | | | ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE PLANS MUST BE | | | STAMPED AND THE RECEIPT ATTACHED TO THE | | | APPLICATION. 233-5025 | | | | | | 2) ON SHEET A-1 PLEASE ADD ADDITION TO THE SCOPE OF | | | WORK AND REVISE GENERAL NOTE 1 TO 2004 FBC WITH 2007 | | | REVISIONS. FBC 106.1.1* CITY AMENDMENTS | | | | | | 3) SUBMIT TWO COPIES OF ENERGY CALCULATIONS FOR THE | | | ADDITION AS REQUIRED BY FBC 13-600. THE PREPARER AND | | | OWNER/AGENT SIGNATURES ARE REQUIRED ON THE FORMS. | | | | | | 4) SHOW COMPLIANCE WITH R807.1 ATTIC ACCESS . IN | | | BUILDINGS WITH COMBUSTIBLE CEILING OR ROOF | | | CONSTRUCTION, AN ATTIC ACCESS OPENING SHALL BE PROVIDED | | | TO ATTIC AREAS THAT EXCEED 30 SQUARE FEET (2.8 M 2 ) | | | AND HAVE A VERTICAL HEIGHT OF 30 INCHES (762 MM) OR | | | GREATER. THE ROUGH-FRAMED OPENING SHALL NOT BE LESS | | | THAN 22 INCHES BY 30 INCHES (559 MM BY 762 MM) AND | | | SHALL BE LOCATED IN A HALLWAY OR OTHER READILY | | | ACCESSIBLE LOCATION. A 30-INCH (762 MM) MINIMUM | | | UNOBSTRUCTED HEADROOM IN THE ATTIC SPACE SHALL BE | | | PROVIDED AT SOME POINT ABOVE THE ACCESS OPENING. SEE | | | SECTION M1305.1.3 FOR ACCESS REQUIREMENTS WHERE | | | MECHANICAL EQUIPMENT IS LOCATED IN ATTICS. | | | | | | 5) SPECIFY HOW THE SECOND FLOOR BALCONY FLOOR WILL BE | | | WATERPROOFED TO PREVENT WATER INTRUSION INTO THE ROOMS | | | BELOW. | | | | | | 6) SPECIFY THE LOCATIONS OF THE FLOOR/CEILING ASSEMBLY | | | DRAFTSTOPPING ON THE PLANS. FBC R502.1.2 | | | | | | 7) PLEASE CORRECT THE TYPO ON THE LEDGER 1 DETAIL ON | | | S-2 FROM 58" DIAMETER ANCHOR BOLTS TO 5/8". | | | | | | 8) PROVIDE STRUCTURAL DETAILS OF THE SECOND FLOOR ROOF | | | AREA FOR THE LARGE OVERHANG AT THE CORNER OF THE MASTER | | | BATHROOM ABOVE THE ANGLE WALL. R801.2 REQUIREMENTS. | | | ROOF AND CEILING CONSTRUCTION SHALL BE CAPABLE OF | | | ACCOMMODATING ALL LOADS IMPOSED ACCORDING TO SECTION | | | R301 AND OF TRANSMITTING THE RESULTING LOADS TO THE | | | SUPPORTING STRUCTURAL ELEMENTS. | | | | | | 9) PROVIDE STRUCTURAL DETAILS OF THE EXISTING ROOF | | | FRAMING AT THE AREA WHERE THE NEW FLOOR GIRDERS | | | SUPPORTED BY THE STEEL COLUMN WILL BE INSTALLED BELOW | | | THE NEW MASTER BATH. R801.2 | | | | | | 10) PROVIDE A ROOF FRAMING PLAN AND DETAILS FOR THE | | | ROOF CRICKETS THAT WILL BE REQUIRED TO DIVERT THE RAIN | | | WATER AWAY FROM THE SECOND FLOOR WALLS OF THE ADDITION. | | | R703.1 | | | | | | 11) FBC 106.3* CITY AMENDMENTS PRODUCT APPROVALS. THOSE | | | PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | | | | 12) SUBMIT TWO COPIES OF PRODUCT APPROVALS FOR THE | | | GLASS BLOCK, EXTERIOR FRENCH DOORS AND STRUCTURAL | | | WINDOW MULLIONS AS REQUIRED BY FAC RULE 9B-72. NOTE: IF | | | PRODUCTS ARE NOT LARGE MISSILE IMPACT RATED, THEN | | | PRODUCT APPROVALS, INSTALLATION SCHEDULES AND KEY PLANS | | | FOR STORM PANELS WILL BE REQUIRED. FBC R301.2.1.2 | | | | | | 13) SHOP DRAWINGS FOR THE EXTERIOR BALCONY WILL BE | | | REQUIRED TO BE SUBMITTED FOR APPROVAL BEFORE THEY ARE | | | INSTALLED. FBC 106.1.2* CITY AMENDMENTS | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2009-01-15 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-01-15 |
Time |
15:53 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-01-15 |
Time |
15:21 |
Sent To |
P |
|
| Notes |
| 2009-01-15 15:53:49 | | | | | | | PROVISO | | | | | | THE 200 AMP PANEL "A", IS NOT RATED FOR THE 266 AMP | | | LOAD IN THE CALCULATIONS. A 150 AMP DISCONNECT MUST BE | | | ADDED OUTSIDE AT THE METER. 230230.70(A)(1) |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2008-10-23 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-10-23 |
Time |
12:02 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-10-23 |
Time |
11:04 |
Sent To |
M |
|
| Notes |
| 2008-10-23 12:02:31 | | | | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2004 | | | RESIDENTIAL BUILDING CODE, 2005 NEC, 2004 FBC CHAPTER 1 | | | AS AMENDED AND FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | | | | ALL COMMENTS RELATE TO SHEET E-2, UNLESS OTHERWISE | | | NOTED. ALL CODE ARTICLES REFERENCED ARE 2005 NEC UNLESS | | | OTHERWISE NOTED. | | | | | | 1} THE FEED FOR PANEL "B"IS SHOWN AS #6 CU WHICH IS | | | RATED FOR AN OCP OF 65 AMPS.(310.16) THE CALCULATION | | | FOR THAT PANEL INDICATE 141 AMPS. THE FEEDER ON THAT | | | PANEL IS LISTED AS A 200 AMP. PLEASE CORRELATE. NOTE: | | | THE AHU'S ALONE ARE ON 60 AMP CIRCUITS. | | | | | | 2} THERE IS A WATER HEATER IN THE CALCULATION FOR PANEL | | | "B" BUT NONE ON THE PANEL SCHEDULE. NOTE THERE IS ALSO | | | A WATER HEATER IN PANEL "A", BUT ONLY ONE SHOWN ON THE | | | FLOOR PLANS @ 100 GAL.408.4 | | | | | | 3} THE FEED FOR PANEL "B" IS LISTED BOTH AS MAIN LUG | | | ONLY AND 200 AMP MAIN BREAKER? | | | | | | THE FOLLOWING COMMENTS REFER TO SHEET E-1: | | | | | | 4} THERE ARE THREE A/C SYSTEMS IN THE LOAD CALCULATIONS | | | BUT ONLY TWO CONDENSING UNITS LOCATED ON THE PLAN. SHOW | | | THE LOCATION OF THE A/C EQUIPMENT ON THE PLAN. ALSO | | | SHOW COMPLIANCE WITH THE REQUIRED DISCONNECT PER | | | 440.14, RECEPTACLE PER 210.63, LIGHT PER 210.70(A) (3). | | | | | | 5} 210.52 (C)(2) ISLAND COUNTER SPACES AT LEAST ONE | | | RECEPTACLE SHALL BE INSTALLED AT EACH ISLAND COUNTER | | | SPACE WITH A LONG DIMENSION OF 600 MM (24 IN.) OR | | | GREATER AND A SHORT DIMENSION OF 300 MM (12 IN.) OR | | | GREATER. WHERE A RANGETOP OR SINK IS INSTALLED IN AN | | | ISLAND COUNTER AND THE WIDTH OF THE COUNTER BEHIND THE | | | RANGETOP OR SINK IS LESS THAN 300 MM (12 IN.), THE | | | RANGETOP OR SINK IS CONSIDERED TO DIVIDE THE ISLAND | | | INTO TWO SEPARATE COUNTERTOP SPACES AS DEFINED IN | | | 210.52(C)(4). | | | | | | 6} 210.52(C)(3) PENINSULAR COUNTER SPACES AT LEAST ONE | | | RECEPTACLE OUTLET SHALL BE INSTALLED AT EACH PENINSULAR | | | COUNTER SPACE WITH A LONG DIMENSION OF 600 MM (24 IN.) | | | OR GREATER AND A SHORT DIMENSION OF 300 MM (12 IN.) OR | | | GREATER. A PENINSULAR COUNTERTOP IS MEASURED FROM THE | | | CONNECTING EDGE. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2009-08-11 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2009-08-11 |
Time |
09:07 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2009-08-11 |
Time |
09:07 |
Sent To |
|
|
| Notes |
| 2009-08-11 09:08:21 | GAVE TO MCDOUGLE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2009-04-17 |
|
|
Cont ID |
|
| Sent By |
swurafti |
Date |
2009-04-17 |
Time |
16:08 |
Rev Time |
0.00 |
| Received By |
swurafti |
Date |
2009-04-17 |
Time |
16:08 |
Sent To |
|
|
| Notes |
| 2009-04-17 16:15:15 | WAITING FOR RESIDENTIAL BOARD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2009-01-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-01-06 |
Time |
14:18 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-01-06 |
Time |
14:18 |
Sent To |
Z |
|
| Notes |
| 2009-01-06 14:19:07 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-10-29 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-10-29 |
Time |
10:02 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-10-14 |
Time |
11:09 |
Sent To |
PC |
|
| Notes |
| 2008-10-14 11:10:00 | TO "SFR" "Z" |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
P |
Date |
2009-05-14 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2009-05-14 |
Time |
11:58 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2009-05-14 |
Time |
11:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
2009-01-13 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2009-01-13 |
Time |
15:21 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2009-01-13 |
Time |
13:24 |
Sent To |
Z |
|
| Notes |
| 2009-01-13 16:15:56 | ***LANDSCAPE REVIEW FAILED*** | | | | | | 1. PURSUANT TO SECTION 94-442(C), PALM TREES MAY BE | | | SUBSTITUTED FOR NOT MORE THAN 35 PERCENT OF THE SHADE | | | OR FLOWERING TREES REQUIRED BY THIS ARTICLE. HOWEVER, | | | WHEN PALM TREES ARE SUBSTITUTED FOR SHADE TREES, TWO | | | PALM TREES SHALL BE PROVIDED FOR EACH REQUIRED SHADE | | | TREE. THIS 2:1 SUBSTITUTION SHALL NOT BE REQUIRED FOR | | | ROYAL PALM TREES AND SUCKERING PALM TREES SUCH AS THE | | | ARECA PALM, PAUROTIS PALM AND THE SENEGAL DATE PALM. | | | WHEN PALMS ARE USED THEY MUST BE PLANTED IN GROUPS OF | | | THREE. TWO ADDITIONAL SHADE OR FLOWERING TREES SHALL BE | | | ADDED TO MEET MINIMUM REQUIREMENTS. | | | | | | 2. PURSUANT TO SECTION 94-442(D) , PRIVATE LAND AND | | | PUBLIC RIGHTS-OF-WAY BETWEEN STREET OR SIDEWALK | | | SURFACES AND REQUIRED BUFFER STRIPS AND LANDSCAPED OPEN | | | SPACE AREAS SHALL BE PLANTED WITH GRASS. GRASS AREAS | | | SHALL BE SODDED. | | | | | | 3. PURSUANT TO SECTION 94-445(4)(G)(3), AUTOMATIC | | | IRRIGATION SYSTEMS SHALL BE USED FOR THE CULTIVATED | | | LANDSCAPE AREAS FOR ALL PROPERTIES. THIS INCLUDES THE | | | RIGHT-OF-WAY. | | | | | | 4. THE GROUND LEVEL AIR CONDITIONING UNITS SHALL BE | | | SCREENED. | | | | | | 5. ALL PROPOSED AND EXISTING PLANT MATERIAL SHALL BE | | | CLEARLY IDENTIFIED. | | | | | | 6. PLEASE PROVIDE THE TABULATION NECESSARY TO | | | DEMONSTATE COMPLIANCE WITH THE XERISCAPE DESIGN OPTIONS | | | REQUIRED FOR SINGLE FAMIILY. | | | | | | 7. PROVIDE A PLANT LIST IDENTIFYING ALL PROPOSED TREES, | | | SHRUBS AND GROUND COVER. IT SHALL INCLUDE THE QUANTITY, | | | SIZE AND SPACING FOR ALL PROPOSED PLANT MATERIAL. | | | | | | 8. PLEASE PROVIDE THE LANDSCAPE INFORMATION IN TABULAR | | | FORM. THE TABULATION SHALL INCLUDE TREES REQUIRED AND | | | TREES PROPOSED, SHRUBS REQUIRED AND SHRUBS PROPOSED. | | | OPEN AREA IS THE DIFFERENCE BETWEEN THE TOTAL LOT AREA | | | AND THE FOOTPRINT OF THE BUILDING. THE TREES AND SHRUBS | | | REQUIRED IS BASED UPON OPEN AREA AND NOT PERVIOUS AREA. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT | | | KUSSNER @ (561) 822-1462. | | | | | | | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2009-05-18 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2009-05-18 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2009-05-18 |
Time |
14:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2009-02-04 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2009-02-04 |
Time |
15:02 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2009-02-04 |
Time |
15:02 |
Sent To |
|
|
| Notes |
| 2009-02-05 07:50:04 | 02/05/2009 PLAN DENIED. | | | PLEASE SUBMIT ENERGY CALCULATIONS PER 2004 FBC | | | 13-101.2.2 | | | PLEASE SUBMIT COOLING LOAD CALCULATIONS PER 2004 FBC | | | 13-607.1.ABC.1 | | | PLEASE SUBMIT MECHANICAL PLANS FOR REVIEW PER 200 FBC | | | CITY OF WPB AMEND. 106.3.5.4 (10) . | | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2008-10-23 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-10-23 |
Time |
16:29 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2008-10-23 |
Time |
16:28 |
Sent To |
P |
|
| Notes |
| 2008-10-23 16:43:33 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | *** DENIED *** | | | 1) PLEASE SUBMIT ENERGY CALCULATIONS, PER 2004 FBC | | | 13-101.2.2. | | | | | | 2) PLEASE SUBMIT COOLING LOAD CALCULATIONS, PER 2004 | | | FBC 13-607.1.ABC.1. | | | | | | 3) PLEASE SUBMIT MECHANICAL (A/C) PLANS FOR REVIEW, PER | | | 2004 FBC CITY OF WPB AMEND. 106.3.5.4 (10). | | | | | | 4) THE MAIN MASTER BATHROOM WILL REQUIRE AN EXHAUST FAN | | | (DUE TO THE BATH TUB AND SHOWER) PER 2004 FBC/R R303.3 | | | | | | 5) THE WINDOW TO THE EXISTING FIRST FLOOR BATHROOM WILL | | | BE ENCLOSED, SHOW ON ELECTRICAL AND MECHANICAL (A/C) | | | PLANS AN EXHAUST FAN NEW OR EXISTING, PER 2004 FBC/R | | | R303.3. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2009-05-18 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2009-05-18 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2009-05-18 |
Time |
11:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2009-02-03 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-02-03 |
Time |
10:54 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-02-03 |
Time |
10:53 |
Sent To |
M |
|
| Notes |
| 2009-02-03 11:18:38 | DENIED | | | REFERENCE: | | | FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | | | | 1. SHT E-2 SANITARY RISER DIAGRAM DOES NOT REFLECT THE | | | FLOOR PLAN, NOR DOES IT MEET CODE REQUIREMENTS. | | | A. THE LAV IN THE POWDER ROOM IS ON THE RIGHT HAND | | | WALL. (SHOWN ON THE LEFT HAND WALL), AND IS NOT VENTED. | | | SECTIONS 106.1.1 & 901.2.1. | | | B. THE DOUBLE LAVS FOR BATH AT BEDROOMS 3 & 4 ARE SHOWN | | | PARALLEL TO THE WALL, NOT OUT INTO THE BATHROOM, AND | | | THE SHOWER IS NOT VENTED. SECTIONS 106.1.1 & 901.2.1. | | | C. THE SECOND FLOOR GUEST BATHROOM TUB IS NOT VENTED. | | | SECTION 901.2.1. | | | | | | 2. SEE RED LINE EXAMPLES SHOWN ON NEW SHEET E-2. | | | | | | 3. REMOVE ALL VOIDED, SUPERSEDED SHEETS AND REPLACE | | | WITH NEW SHEETS. PLANS SHALL BE SUBMITTED IN TWO BOUND | | | SETS. LOOSE SHEETS NOT APPROVED. SECTION 106.1.3. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2008-10-28 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-10-29 |
Time |
16:37 |
Rev Time |
1.30 |
| Received By |
mperson |
Date |
2008-10-28 |
Time |
16:37 |
Sent To |
I |
|
| Notes |
| 2008-10-28 16:58:03 | PLUMBING PLAN REVIEW: | | | DENIED: | | | | | | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | | PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE. | | | | | | 1. SHEET E-2 SANITARY ISOMETRIC: PLEASE CORRECT THE | | | FOLLOWING PER THE FBC-2004 PLUMBING CODE SECTIONS. | | | | | | A} THE CLEANOUTS BEING INDICATED FOR THE SECOND FLOOR | | | ARE BEING INDICATED IN THE WRONG PLACE. THOSE CLEANOUTS | | | SHOULD BE CORRECTLY LOCATED AT THE BASE OF THOSE SOIL | | | AND WASTE STACKS ON THE FIRST FLOOR. PLEASE CORRECT PER | | | SECTION 708.3.4 BASE OF STACK. | | | | | | B} THE ISOMETRIC DOES NOT REFLECT THE FIRST FLOOR PLAN | | | INDICATED ON SHEET A-3. THE WATER CLOSET IS MISSING | | | FROM THE FIRST FLOOR BATHROOM (ROOM NOT NUMBERED) BY | | | BEDROOM 3 AND BEDROOM 4. PLEASE KNOW THAT THE ISOMETRIC | | | IS INDICATING THREE LAVATORIES FOR THIS BATHROOM, | | | HOWEVER THE FIRST FLOOR PLAN ON SHEET A-3 ONLY | | | INDICATES TWO LAVATORIES. PLEASE CORRECT PER SECTION | | | 106.1.1 (W.P.B. AS AMENDED) INFORMATION ON CONSTRUCTION | | | DOCUMENTS AND SECTION 701.1 SCOPE. | | | | | | C} THE ISOMETRIC DOES NOT REFLECT THE FIRST FLOOR PLAN | | | INDICATED ON SHEET A-3. THE ISOMETRIC SHOULD CLEARLY | | | INDICATE THE REQUIRED BRANCH COMBINATION WYE AND EIGHTH | | | BEND FITTING FROM THE MAIN TO THE POWDER ROOM BATHROOM. | | | PLEASE KNOW AT A MINIMUM THE SANITARY ISOMETRIC RISER | | | DIAGRAM SHOULD REFLECT THE FLOOR PLAN. PLEASE CORRECT | | | PER SECTION 106.1.1 (W.P.B. AS AMENDED) INFORMATION ON | | | CONSTRUCTION DOCUMENTS AND SECTION 701.1 SCOPE. | | | | | | D} THE SECOND FLOOR BATHTUB IN THE TUB BATHROOM (ROOM | | | NOT NUMBERED) IS NOT VENTED. THE BATHTUB WASTE BRANCH | | | FITTING SHOULD BE LOCATED ABOVE THE WATERCLOSET AND | | | BELOW THE LAVATORY TO BE VENTED. PLEASE CORRECT PER | | | SECTION 901.2.1 VENTING REQUIRED. | | | | | | ********IMPORTANT INFORMATION******** | | | WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE | | | OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW | | | PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | END OF COMMENTS: | | | | | | *PLEASE CALL IF THERE ARE ANY QUESTIONS. | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | PHONE= (561) 805-6730 | | | FAX= (561) 805-6731 | | | E-MAIL= [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2009-05-15 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2009-05-15 |
Time |
09:37 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2009-05-15 |
Time |
08:22 |
Sent To |
|
|
| Notes |
| 2009-05-15 09:40:01 | PLACED BACK ON RES RACK (R-7) |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2009-01-14 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2009-01-14 |
Time |
08:11 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2009-01-13 |
Time |
10:04 |
Sent To |
E |
|
| Notes |
| 2009-01-14 08:12:35 | PLANNING AND ZONING DEPT: ***ZONING FAILED*** | | | | | | 1. PLEASE PROVIDE ALL RESPONSES IN WRITING. | | | | | | 2. PLEASE ADDRESS LANDSCAPE PLAN REVIEWER COMMENTS. | | | | | | NOTE: THE SUBMITTAL OF THE REQUESTED INFORMATION MAY | | | GENERATE ADDITIONAL COMMENTS. | | | | | | FOR ADDITIONAL INFORMATION, THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT | | | WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH | | | PLANNING DEPARTMENT WEBSITE AT | | | WWW.CITYOFWPB.COM/PLAN/INDEX.HTM. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | | CONTACT ME. | | | | | | MAGGIE CRUZ, ASSOCIATE PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: (561) 822-1444 OR (561) 805-6720 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2008-10-16 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2008-10-16 |
Time |
10:17 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2008-10-16 |
Time |
10:07 |
Sent To |
I |
|
| Notes |
| 2008-10-16 10:17:19 | ***ZONING FAILED*** | | | | | | 1. PLEASE PROVIDE ALL RESPONSES IN WRITING. | | | | | | 2. INDICATE THE SETBACK DIMENSIONS FROM ANY EXTERIOR | | | IMPROVEMENTS TO ALL ADJACENT PROPERTY LINES. NOTE: | | | PURSUANT TO THE CITY OF WEST PALM BEACH ZONING AND LAND | | | DEVELOPMENT REGULATIONS (ZLDR), SECTION 94-72: SINGLE | | | FAMILY LOW DENSITY (SF7) RESIDENTIAL DISTRICT - MINIMUM | | | SETBACKS FOR PRINCIPAL BUILDING ARE AS FOLLOWS: | | | | | | A. FRONT: 25 FEET; | | | | | | B. CORNER: 12.5 FEET; TEN FEET IF LOT IS LESS THAN 60 | | | FEET WIDE; | | | | | | C. REAR: 15 FEET OR TEN PERCENT OF DEPTH, WHICHEVER IS | | | LESS; | | | | | | D. SIDE: FIVE FEET MINIMUM, 15 FEET TOTAL. | | | | | | 3. INDICATE SETBACK DIMENSIONS FROM ANY PROPOSED AND/OR | | | RELOCATED A/C EQUIPMENT TO ALL PROPERTY LINES. PURSUANT | | | TO THE ZLDR, SECTION 94-305(B)(4): MECHANICAL EQUIPMENT | | | MAY NOT PROJECT MORE THAN 4 FEET INTO A REQUIRED | | | SETBACK. | | | | | | 4. PURSUANT TO THE ZLDR, SECTION 94-441(C)(2): AS THE | | | VALUE OF THE PROPOSED WORK EXCEEDS 50% OF THE | | | STRUCTURE'S VALUE (LISTED AS "IMPROVEMENT VALUE" WITH | | | THE P.B.C. PROPERTY APPRAISER'S OFFICE), LANDSCAPING | | | SHALL BE IN COMPLIANCE WITH ALL APPLICABLE REGULATIONS | | | FOUND IN ARTICLE XIV OF THE ZLDR. | | | | | | PLEASE SUBMIT TWO (2) COPIES OF A LANDSCAPE PLAN | | | SHOWING COMPLIANCE WITH SECTIONS 94-442 AND 94-445 OF | | | THE ZLDR. | | | | | | 5. INDICATE IF ANY TREES WILL BE REMOVED AS A RESULT OF | | | THE PROPOSED PROJECT. IF YES, A TREE ALTERATION/REMOVAL | | | PERMIT WILL BE REQUIRED. CONTACT ROBERT KUSSNER, CITY | | | LANDSCAPE PLANNER, AT (561) 822-1462 FOR THE | | | APPLICATION. | | | | | | NOTE: THE SUBMITTAL OF THE REQUESTED INFORMATION MAY | | | GENERATE ADDITIONAL COMMENTS. | | | | | | FOR ADDITIONAL INFORMATION, THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT | | | WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH | | | PLANNING DEPARTMENT WEBSITE AT | | | WWW.CITYOFWPB.COM/PLAN/INDEX.HTM. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | | CONTACT ME. | | | | | | MAGGIE CRUZ, ASSOCIATE PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: (561) 822-1444 OR (561) 805-6720 | | | E-MAIL: [email protected] | | | | | | | | | |
|
|