| Plan Review Stops For Permit 08100146 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2008-10-21 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-10-21 |
Time |
08:39 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-10-21 |
Time |
08:39 |
Sent To |
|
|
| Notes |
| 2008-10-21 08:39:14 | BUILDING PROVISO: | | | TO BE IN PLACE AT C.O: | | | | | | PUBLIC POOLS | | | 424.1.3.1.9 ALL PUBLIC POOLS SHALL BE SURROUNDED BY A | | | MINIMUM 48" IN HEIGHT FENCE. A SELF LATCHING SELF | | | CLOSING LOCKABLE GATE OF 48" MINIMUM HEIGHT WITH THE | | | LATCH LOCATED NEAR THE TOP. SAFETY COVERS THAT COMPLY | | | WITH ASTM F 1346 DO NOT SATIFY THIS REQUIREMENT. | | | | | | 13-412.1ABC2.6.2 POOL COVERS. HEATED POOLS SHALL BE | | | EQUIPPED WITH A VAPOR RETARDANT POOL COVER ON OR AT THE | | | WATER SURFACE. POOLS HEATED TO MORE THAN 90 DEGREES (F) | | | SHALL HAVE A POOL COVER WITH A MINIMUM INSULATION VALUE | | | OF R-12. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2008-12-04 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-12-04 |
Time |
16:05 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-12-04 |
Time |
16:05 |
Sent To |
PC |
|
| Notes |
| 2008-12-04 16:06:07 | NEW LETTER FROM HEALTH DEPT E-MAILED |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
N |
Date |
2008-11-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-11-20 |
Time |
13:31 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
|
Time |
|
Sent To |
PC |
|
| Notes |
| 2008-11-20 13:31:32 | NOTES AS PLACED ON FRONT SCREEN. | | | | | | | | | 11/20/08 PLANS PLACED OUTFRONT TO BE PICKED UP. NO | | | REVIEW WAS DONE. UNDER "A" (LARGE BINS) PLANS NEED TO | | | GO BACK FOR CONTRACTOR TO OBTAIN NEW PERMIT FOR SOIL | | | REMOVAL FROM EPA DUE TO CONTAMINATED SOIL. SPOKE TO | | | DENISE, NO RE-SUB FEE WILL BE CHARGED WHEN BRINGING | | | PLANS BACK IN. DV PALMER. | | | | | 2008-11-19 14:36:28 | ON HOLD, WAITNG FOR ANSWER ON EPA PERMIT FOR | | | CONTAMINATED SOIL. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2008-10-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-10-21 |
Time |
15:35 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-10-21 |
Time |
15:35 |
Sent To |
|
|
| Notes |
| 2008-10-21 15:35:20 | | | | ** DENIED REVIEW** | | | | | | | | | | | | | | | 1) NOTE: PLANS REFLECT NOTES FOR DECK BONDING QUOTING | | | FBC 2004104.2.3 FOR ALTERNATE METHODS AND MATERIALS. | | | THIS IS INCORRECT. THE PLANS NEED TO CONTAIN A DESIGN | | | AND ANY NOTES FROM THE 2005 NFPA-70. ( NEC). | | | CHAPTER 1 OF THE FLORIDA BUILDING CODE IS | | | ADMINISTRATIVE AS ADOPTED BY EACH JURISDICTION. THIS | | | SECTION AS NOTED ON PLANS IS NOT VALID WITH THE CITY OF | | | WEST PALM BEACH AS AN ADOPTED SECTION FOR THIS SAME | | | NOTE. | | | THE FACT REMAINS ALL DESIGN FOR THE EQUAL-POTENTIAL | | | BONDING GRID SHALL BE PER THE NEC AS NOTED ABOVE. | | | | | | 2) NOTE: PLEASE ONLY INCLUDE ELECTRICAL FOR THE POOL | | | SCOPE OF WORK AS APPLIED. THE PLANS INDICATE LIGHTING | | | ETC. | | | | | | 3) NOTE: PLEASE BE SURE ALL CONTINUOUS LOADS ARE SHOWN | | | AT 125%. | | | 230.42,215.3 ETC | | | | | | | | | **IMPORTANT** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | | TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANOR PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2008-10-23 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-10-23 |
Time |
08:46 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-10-23 |
Time |
08:46 |
Sent To |
|
|
| Notes |
| 2008-10-23 08:47:31 | SEPARATE GAS PERMIT REQUIRED FOR GAS POOL HEATER WITH | | | POOL HEATER SUBMITTAL. NO GAS INFORMATION SUBMITTED. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-11-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-11-10 |
Time |
16:04 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-11-10 |
Time |
16:03 |
Sent To |
E |
|
| Notes |
| 2008-11-10 16:04:32 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-10-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-10-24 |
Time |
13:39 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-10-08 |
Time |
08:42 |
Sent To |
|
|
| Notes |
| 2008-10-08 08:48:57 | TO "COMM" BD#18 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2008-10-23 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-10-23 |
Time |
08:42 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-10-22 |
Time |
16:55 |
Sent To |
|
|
| Notes |
| 2008-10-23 08:48:55 | PROVISO: GAS PERMIT REQUIRED. POOL HEATER SUBMITTAL AND | | | RISER DIAGRAM REQUIRED AT TIME OF APPLICATION. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2008-10-17 |
|
|
Cont ID |
|
| Sent By |
lfranco |
Date |
2008-10-17 |
Time |
13:25 |
Rev Time |
0.00 |
| Received By |
lfranco |
Date |
2008-10-17 |
Time |
13:24 |
Sent To |
|
|
| Notes |
| 2008-10-17 13:29:28 | PLANNING AND ZONING: **** PASSED WITH PROVISO **** | | | | | | 1. RESPOND TO COMMENTS IN WRITING. | | | | | | 2. A FENCE PERMIT SHALL BE SUBMITTED CONCURRENTLY AND | | | SHALL CONFORM TO THE MINIMUM STANDARDS PROVIDED BELOW: | | | | | | PURSUANT TO THE APPROVED SITE PLAN FOR COURTNEY LAKES | | | HAWTHORN SUITES HOTEL: | | | | | | THE FENCE SHALL BE A MINIMUM OF 48 INCHES HIGH. THE | | | FENCE SHALL HAVE A SELF-CLOSING AND SELF-LATCHING GATE | | | WITH LATCHES PLACED AT LEAST 54 INCHES ABOVE BOTTOM OF | | | GATE. | | | | | | 3. IF A PATIO OR PAVED AREA IS PROVIDED ADJACENT TO OR | | | SURROUNDING A POOL, IT SHALL BE DESIGNED TO DRAIN AWAY | | | FROM THE POOL, BUT NOT ONTO ADJACENT PROPERTIES. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ME. | | | | | | LINDA MIA FRANCO | | | SENIOR PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: (561) 822-1443 | | | EMAIL: [email protected] | | | |
|
|