Plan Review Details - Permit 08100026
Plan Review Stops For Permit 08100026
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2008-11-10 Cont ID  
Sent By mjacobs Date 2008-11-10 Time 15:11 Rev Time 0.00
Received By mjacobs Date 2008-11-10 Time 15:11 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-10-09 Cont ID  
Sent By mjacobs Date 2008-10-09 Time 08:41 Rev Time 0.00
Received By mjacobs Date 2008-10-09 Time 07:42 Sent To  
Notes
2008-10-09 08:41:27BUILDING PLAN REVIEW
 PERMIT: 08100026
 ADD: 1641 WORTHINGTON ROAD #110
 CONT: DPR CONSTRUCTION INC.
 TEL: (561)273-6300
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 10-9-08
 REVIEW: 1ST
 ACTION: DENIED
  
 1) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE & REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 2) THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE
 CONSTRUCTION SITE BEFORE THE FIRST INSPECTION.
  
 3) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) AFTER
 JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC
 BUILDING WITH THE 2007 SUPPLEMENTS. THIS INFORMATION
 SHALL BE INDICATED ON THE DRAWINGS.
  
 4) 2004 FBC EXISTING 301.5 A DESIGN PROFESSIONAL OR AN
 OWNER MUST ELECT ONE OR A COMBINATION OF LEVELS OF
 ALTERATION PURSUANT TO SECTIONS 303, 304 AND 305 OF
 THIS CODE. INDICATE THE LEVEL OF ALTERATION ON THE
 PLANS.
  
 5) STATE THE USE AND OCCUPANCY OF THE BUILDING PER FBC
 CHAPTER 3, THE TYPE OF BUILDING PER FBC CHAPTER 6 AND
 TABLE 601 AND THE OCCUPANT LOAD OF THE SPACE PRE TABLE
 1004.1.2. THIS INFORMATION IS REQUIRED TO CONFORM TO
 OUR RECORD RETENTION PROGRAM. 106.1.3*
  
 6) SHEET A-4.01.1 DETAIL #2 WINE BAR COUNTER SHALL MEET
 THE REQUIREMENTS OF FBC 11-5.2 COUNTERS AND BARS WHERE
 FOOD OR DRINK IS SERVED @ COUNTERS EXCEEDING 34" IN
 HEIGHT FOR CONSUMPTION BY CUSTOMERS SEATED ON STOOLS OR
 STANDING AT THE COUNTER, A PORTION OF THE MAIN COUNTER
 WHICH IS 60" IN LENGTH MINIMUM SHALL BE PROVIDED IN
 COMPLIANCE WITH 11-4.32 OR SERVICE SHALL BE AVAILABLE
 AT ACCESSIBLE TABLES WITHIN THE SAME AREA. SHOW
 COMPLIANCE.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 (561)805-6726
 [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2008-11-14 Cont ID  
Sent By btrobaug Date 2008-11-14 Time 09:57 Rev Time 0.00
Received By btrobaug Date 2008-11-14 Time 09:38 Sent To PC
Notes
2008-11-14 09:39:03 
  
 NEW SHEETS./WRT.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2008-10-08 Cont ID  
Sent By btrobaug Date 2008-10-08 Time 15:04 Rev Time 0.00
Received By btrobaug Date 2008-10-08 Time 13:22 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2008-11-12 Cont ID  
Sent By mwennerg Date 2008-11-12 Time 15:35 Rev Time 0.00
Received By mwennerg Date 2008-11-12 Time 15:35 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2008-10-16 Cont ID  
Sent By mawillia Date 2008-10-16 Time 14:12 Rev Time 0.00
Received By mawillia Date 2008-10-16 Time 13:40 Sent To  
Notes
2008-10-16 14:12:10*****DENIED*****
  
 1. THE SUITE NUMBER SHALL BE INCLUDED IN THE ADDRESS
 (SCOPE OF WORK LOCATION) IN THE TITLE BLOCK OF EACH
 SUBMITTED PLAN SHEET. SUITE NUMBER IS MISSING ON SHEETS
 E0.1 THRU E6.1, FA0.1 & FA2.1, M0.1 THRU M2.2 AND P0.1
 & P2.1.
  
 2. STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR
 DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241.
  
 3. COMBUSTIBLE WASTE MATERIALS, DUST, AND DEBRIS SHALL
 BE REMOVED FROM THE SITE AT THE END OF THE DAY OR MORE
 FREAUENTLY FOR SAFE OPERATIONS.
  
 4. THE SCOPE OF WORK SHALL NOT HIDER OR INTERFERE WITH
 ACCESS TO / EGRESS FROM OTHER TENANT SPACES ON THE
 FLOOR AND/OR BUILDING.
  
 5. NFPA 101, LIFE SAFETY CODE, 2003 EDITION SHALL BE
 REFERENCED.
  
 6. PROVIDE A LAYOUT OF THE FIRE SPRINKLER HEADS FOR
 THIS TENANT SPACE. NOTE: THESE DEVICES CAN BE SHOWN ON
 THE REFLECTED CEILING PLAN SHEET.
  
  
 TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE
 LETTER INDICATING WHERE ON THE APPROPIATE PLAN SHEET
 EACH ITEM WAS ADDRESSED
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-11-06 Cont ID  
Sent By adarroug Date 2008-11-06 Time 10:52 Rev Time 0.00
Received By adarroug Date 2008-11-06 Time 10:52 Sent To  
Notes
2008-11-06 10:55:08TO "BOB"#10

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-10-16 Cont ID  
Sent By mawillia Date 2008-10-16 Time 13:41 Rev Time 0.00
Received By mawillia Date 2008-10-02 Time 14:04 Sent To  
Notes
2008-10-02 14:07:13TO "BOB"#4

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2008-11-07 Cont ID  
Sent By tgordon Date 2008-11-07 Time 08:11 Rev Time 0.45
Received By tgordon Date 2008-11-07 Time 08:11 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2008-11-06 Cont ID  
Sent By mperson Date 2008-11-06 Time 14:17 Rev Time 1.00
Received By mperson Date 2008-11-06 Time 14:17 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2008-10-09 Cont ID  
Sent By mperson Date 2008-10-09 Time 11:08 Rev Time 1.00
Received By mperson Date 2008-10-09 Time 11:08 Sent To  
Notes
2008-10-09 11:37:33PLUMBING PLAN REVIEW:
 DENIED:
  
 PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH
 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO
 CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE
 (F.A.C.), AND FLORIDA STATUTES (F.S.).
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE.
  
 1. PLEASE CLEARLY INDICATE THE BUILDING CLASSIFICATION
 AND OCCUPANCY LOAD ON THE PLANS.
 PER FBC BUILDING SECTION 302.1 GENERAL. STRUCTURES OR
 PORTIONS OF STRUCTURES SHALL BE CLASSIFIED WITH RESPECT
 TO OCCUPANCY IN ONE OR MORE OF THE GROUPS LISTED BELOW.
  
 A} ASSEMBLY (SEE SECTION 303): GROUPS A-1, A-2, A-3,
 AND A-5
  
 B} BUSSINESS (SEE SECTION 304): GROUP B
  
 C} EDUCATIONAL (SEE SECTION 305): GROUP E
  
 D} FACTORY AND INDUSTRIAL (SEE SECTION 306): GROUPS F-1
 AND F-2
  
 E} HIGH HAZARD (SEE SECTION 307) GROUPS H-1, H-2, H-3,
 H-4, AND H-5
  
 F} INSTITUTIONAL (SEE SECTION 308): GROUP I-1, I-2, AND
 I-3
  
 G} MERCANTILE (SEE SECTION 309): GROUP M
  
 H} RESIDENTIAL (SEE SECTION 310): GROUPS R-1, R-2, R-3
 AS APPLICABLE IN SECTION 101.2, AND R-4
  
 I} STORAGE (SEE SECTION 311): GROUPS S-1 AND S-2
  
 J} UTILITY AND MISCELLANEOUS (SEE SECTION 312): GROUP U
  
 K} DAY CARE (SEE SECTION 313): GROUP D
  
 2. CLEARLY INDICATE THE CODE CYCLE ON THE PLANS. PER
 CITY OF WPB AMENDMENTS TO CHAPTER 1, (W.P.B. AS
 AMENDED) SECTION 106.5 RETENTION OF CONSTRUCTION
 DOCUMENTS.
 THE CURRENT CODE CYCLE FOR THE PLANS IS "FBC-2004 WITH
 2007 REVISIONS".
  
 3. DECLARE THE LEVEL OF ALTERATION, PER FBC-2004
 EXISTING BUILDING CHAPTER 3.
  
 4. SHEET A-4.01.3, BREAK AREA ELEVATION: CLEARLY
 INDICATE THE FOLLOWING REQUIREMENTS TO THE BREAK AREA
 SINK PER THE FBC-2004 CHAPTER 11, FLORIDA ACCESSIBILITY
 CODE SECTIONS.
  
 A} SECTION 11-4.24.3 KNEE CLEARANCE. MINIMUM 27" HIGH,
 30" WIDE, AND 19" DEEP.
  
 B} SECTION 11-4.24.5 CLEAR FLOOR SPACE. 30" X 48" AND
 CLEAR FLOOR SPACE SHALL EXTEND A MAXIMUM OF 19"
 UNDERNEATH THE SINK.
  
 C} SECTION 11-4.24.6 EXPOSED PIPES AND SURFACES.
 INSULATE TO PROTECT AGAINST CONTACT.
  
 5. SHEET A-1.00-1 FLOOR PLAN: CLEARLY INDICATE THE
 REQUIRED TURNING SPACE FOR PEOPLE IN WHEELCHAIRS FOR
 THE BREAK AREA ROOM #103. PER THE FBC-2004 CHAPTER 11,
 FLORIDA ACCESSIBILITY CODE SECTION 11-4.22.3 CLEAR
 FLOOR SPACE. WHEELCHAIR TURNING SPACE SHALL BE
 180-DEGREE WITH A MINIMUM 60" CLEAR FLOOR SPACE.
  
 ********IMPORTANT INFORMATION********
 WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE
 OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW
 PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 END OF COMMENTS:
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 PHONE= (561) 805-6730
 FAX= (561) 805-6731
 E-MAIL= [email protected]

Review Stop Z ZONING
Rev No 1 Status N Date 2008-10-07 Cont ID  
Sent By jroach Date 2008-10-07 Time 20:15 Rev Time 0.00
Received By jroach Date 2008-10-07 Time 20:15 Sent To  
Notes
***NONE***