Plan Review Details - Permit 08090755
| Plan Review Stops For Permit 08090755 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
N |
Date |
2008-10-16 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-10-16 |
Time |
10:45 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2008-10-16 |
Time |
10:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2008-10-31 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-10-31 |
Time |
15:22 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-10-31 |
Time |
15:22 |
Sent To |
|
|
| Notes |
| 2008-10-31 15:22:44 | REDLINED PLANS. | | | MISSING THE PRINTED NAME AND PRINTED LICENSE NUMBER OF | | | THE ARCHITECT ON TITLE BLOCKS PER FAC 61G1-16.004 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2008-10-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-10-14 |
Time |
16:14 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-10-14 |
Time |
16:13 |
Sent To |
|
|
| Notes |
| 2008-10-14 16:14:13 | ** DENIED REVIEW** | | | | | | | | | 1) NOTE: COMMENTS FROM OTHER TRADES SEEM THEY MAY | | | AFFECT THE ELECTRICAL PLANS. | | | | | | 2) NOTE: PLEASE INDICATE THE LOADS OF EXISTING WITH | | | NEW. | | | 220. | | | FBC 106.3.5.1.2 | | | | | | | | | | | | **IMPORTANT** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | | TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANOR PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-10-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-10-24 |
Time |
14:34 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-10-24 |
Time |
14:34 |
Sent To |
|
|
| Notes |
| 2008-10-24 14:37:18 | TO "COMM" BD#14 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-10-16 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-10-16 |
Time |
10:46 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2008-10-01 |
Time |
10:52 |
Sent To |
|
|
| Notes |
| 2008-10-01 10:52:20 | TO "COMM" BD#31 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2008-11-06 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-11-06 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-11-06 |
Time |
14:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2008-10-10 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-10-10 |
Time |
14:07 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-10-10 |
Time |
14:07 |
Sent To |
|
|
| Notes |
| 2008-10-10 14:16:08 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | CITY WPB MUNICIPAL CODE | | | | | | 1. UPON CONVERSATION WITH THE CONTRACTOR, HE INDICATED | | | THAT THE BUS WASH FACILITY WAS SELF CONTAINED AND THAT | | | IT DID NOT CONNECT TO THE SANITARY SEWER SYSTEM. BUT | | | UPON READING THE MANUF. SPECIFICATION SHEETS IN THE 4TH | | | SHEET, ENVIRONMENTAL COMPLIANCE EQUIPMENT, WRITTEN | | | PROPOSAL, IT STATES THAT THE RESULTING EFFLUENT CAN BE | | | DISCHARGED DIRECTLY TO THE SANITARY SEWER AND THE | | | SYSTEM FILLED WITH FRESH WATER TO BE RECYCLED. THE | | | UTILITY DEPT. INDUSTRIAL PRE-TREATMENT SHALL DETERMINE | | | IF AN OIL INTERCEPTOR IS REQUIRED AND SUBMIT A WRITTEN | | | DETERMINATION PRIOR TO PERMIT BEING ISSUED. ARTICLE III | | | SECTION 90-124(7). | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2008-10-08 |
|
|
Cont ID |
|
| Sent By |
bpowell |
Date |
2008-10-08 |
Time |
11:14 |
Rev Time |
0.00 |
| Received By |
bpowell |
Date |
2008-10-08 |
Time |
11:14 |
Sent To |
|
|
| Notes |
|
|
|