Plan Review Details - Permit 08090707
Plan Review Stops For Permit 08090707
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2008-10-29 Cont ID  
Sent By mjacobs Date 2008-10-29 Time 07:32 Rev Time 0.00
Received By mjacobs Date 2008-10-29 Time 07:32 Sent To PC
Notes
2008-10-29 07:32:30PROVISOR:
 THE REMOVAL OF THE OF THE HANDICAP RAMP SHALL BE
 APPROVED BY THE INSPECTOR PRIOR TO REMOVAL.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-10-07 Cont ID  
Sent By mjacobs Date 2008-10-07 Time 12:56 Rev Time 0.00
Received By mjacobs Date 2008-10-07 Time 12:56 Sent To P
Notes
2008-10-07 12:55:57BUILDING PLAN REVIEW
 PERMIT: 08090707
 ADD: 1900 CONSULATE PL.
 CONT: TRIPLE- M-BRICK PAVERS INC.
 TEL: (561)575-0300
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW: 1ST
 ACTION: DENIED
  
 1) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE & REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 2) THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE
 CONSTRUCTION SITE BEFORE THE FIRST INSPECTION.
  
 3) FBC 424.1.3.1.2 SHOW HOW THE POOL DECK WILL BE
 UNIFORMLY SLOPE A MINIMUM OF 2 PERCENT AND A MAXIMUM OF
 4 PERCENT AWAY FROM THE POOL TO DECK DRAINS OR OTHER
 METHODS TO PREVENT STANDING WATER ON THE DECK. PROVIDE
 CRAFTSMAN QUALITY DRAWINGS WITH A MINIMUM 1/8 INCH
 SCALE SHOWING COMPLIANCE. THE CONTRACT ALSO INDICATES
 THE REMOVAL OF A HANDICAP RAMP; SHOW ON THE DRAWINGS
 HOW THE REMOVAL OF THE RAMP WILL NOT AFFECT
 ACCESSIBILITY TO THE POOL. BEFORE THIS RAMP IS REMOVED
 CONTACT KEN CONRAD AT 805-6666 FOR A PRE-INSPECTION OF
 THE AREA. THE DRAWINGS NEED TO CLEARLY INDICATE THE
 POOL DECK AREA.
  
 4) 106.1.1 CONSTRUCTION DOCUMENTS SHALL BE OF
 SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND
 EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT
 WILL CONFORM TO THE PROVISIONS OF THE CODE. THE
 DRAWINGS SUBMITTED DO NOT CLEARLY INDICATE THE PROPOSED
 WORK.
  
 NOTE: PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW)
 AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC
 BUILDING WITH THE 2007 SUPPLEMENTS.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 (561)805-6726
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2008-10-20 Cont ID  
Sent By adarroug Date 2008-10-20 Time 08:54 Rev Time 0.00
Received By adarroug Date 2008-10-20 Time 08:54 Sent To Z
Notes
2008-10-20 08:54:32TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-10-06 Cont ID  
Sent By mcruz Date 2008-10-07 Time 11:56 Rev Time 0.00
Received By adarroug Date 2008-10-06 Time 09:52 Sent To B
Notes
2008-10-06 09:54:27TO "MISC" BOX#2

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-10-08 Cont ID  
Sent By mperson Date 2008-10-08 Time 08:53 Rev Time 0.00
Received By mperson Date 2008-09-30 Time 09:58 Sent To PC
Notes
2008-09-30 09:58:50TO "Z" BOX

Review Stop P PLUMBING
Rev No 2 Status P Date 2008-10-28 Cont ID  
Sent By mperson Date 2008-10-28 Time 14:47 Rev Time 0.30
Received By mperson Date 2008-10-28 Time 14:47 Sent To B
Notes
2008-10-28 14:55:22*****************PROVISO****************
 A} PER FBC-2004 PLUMBING SECTION 1101.5 CONTINUOUS
 FLOW: THE SIZE OF A DRAINAGE PIPE SHALL NOT BE REDUCED
 IN SIZE.
  
 B} PER FBC-2004 PLUMBING SECTION 1101.6 FITTINGS AND
 CONNECTIONS: ALL CONNECTIONS AND CHANGES IN DIRECTION
 OF THE STORM DRAINAGE SYSTEM SHALL BE MADE WITH
 APPROVED DRAINAGE-TYPE FITTINGS AND THE FITTINGS SHALL
 NOT OBSTRUCT OR RETARD FLOW IN SYSTEM.
  
 * IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL: [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2008-10-07 Cont ID  
Sent By mperson Date 2008-10-07 Time 16:45 Rev Time 0.45
Received By mperson Date 2008-10-07 Time 16:45 Sent To I
Notes
2008-10-07 16:56:50PLUMBING PLAN REVIEW:
 DENIED:
  
 PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH
 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO
 CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE
 (F.A.C.), AND FLORIDA STATUTES (F.S.).
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE.
  
 1. THERE ARE TWO DIFFERENT PLANS INDICATING TWO
 DIFFERENT DECK DRAINAGE POINTS OF DISCHARGE. ONE POINT
 OF DISCHARGE IS TO A STORM DRAIN AND THE OTHER POINT OF
 DISCHARGE IS TO A PLANTER. PLEASE CORRELATE PLANS TO
 INDICATE THE DECK DRAIN WITH ONE POINT OF DISCHARGE.
 ALSO CLEARLY INDICATE THE DECK DRAIN PIPE SIZE ON THE
 RESUBMITTAL. PER FBC-2004 PLUMBING SECTION 1101.1 SCOPE
 AND FBC-2004 CHAPTER 1, (W.P.B. AS AMENDED) SECTION
 106.1.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 2. PLEASE CLARIFY ON THE RESUBMITTAL IF THE DECK DRAINS
 ARE BEING PROPOSED NEW OR EXISTING AND PROVIDE A DETAIL
 OF HOW THE DRAINS WILL BE INSTALLED WITH THE NEW BRICK
 PAVERS. PER FBC-2004 PLUMBING SECTION 1101.1 SCOPE.
  
 END OF COMMENTS:
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL: [email protected]

Review Stop Z ZONING
Rev No 2 Status P Date 2008-10-24 Cont ID  
Sent By mcruz Date 2008-10-24 Time 11:59 Rev Time 0.00
Received By mcruz Date 2008-10-24 Time 11:59 Sent To P
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2008-10-07 Cont ID  
Sent By mcruz Date 2008-10-04 Time 14:50 Rev Time 0.00
Received By mcruz Date 2008-10-04 Time 14:49 Sent To I
Notes
2008-10-04 14:49:54***ZONING FAILED***
  
 1. PLEASE PROVIDE ALL RESPONSES IN WRITING.
  
 2. PROVIDE TWO (2) COPIES OF A CURRENT SURVEY, WHICH
 INCLUDES THE PROPERTY'S ADDRESS AND LEGAL DESCRIPTION.
 THE SITE PLAN/SURVEY SUBMITTED WAS NOT LEGIBLE AND DID
 NOT INCLUDE THE PROPERTY'S ADDRESS OR LEGAL
 DESCRIPTION.
  
 NOTE: IF A PATIO OR PAVED AREA IS PROVIDED ADJACENT TO
 OR SURROUNDING A POOL, IT SHALL BE DESIGNED TO DRAIN
 AWAY FROM THE POOL, BUT NOT ONTO ADJACENT PROPERTIES.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO
 CONTACT ME.
  
 MAGGIE CRUZ, ASSOCIATE PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: (561) 822-1444 OR (561) 805-6720
 E-MAIL: [email protected]
  