Plan Review Details - Permit 08090701
Plan Review Stops For Permit 08090701
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2009-02-13 Cont ID  
Sent By rmcdouga Date 2008-12-31 Time 14:55 Rev Time 0.00
Received By rmcdouga Date 2008-12-31 Time 14:55 Sent To  
Notes
2008-12-31 15:01:14REVISION TO CHANGE TO NON-IMPACT WINDOWS
  
 CALLED OWNER BUILDER, WILL BRING IN THE CORRECT PRODUCT
 APPROVALS ON 1/2/09 AT 8 AM.
  
 1/20/09 SPOKE TO OWNER/BUILDIER WHO HAS EXISTING STEEL
 STORM PANELS THAT WERE NOT PERMITTED AND CAN NOT FIND
 PRODUCT APPROVALS FOR THEM.
  
 REVISION APPROVED WITH PROVISO THAT OWNER BUILDER IS
 REQUIRED TO SUBMIT PRODUCT APPROVALS FOR REQUIRED
 IMPACT PROTECTION BEFORE FINAL. FBC R301.2.1.2

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2008-11-05 Cont ID  
Sent By rmcdouga Date 2008-11-05 Time 16:16 Rev Time 0.00
Received By rmcdouga Date 2008-11-05 Time 16:16 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-10-09 Cont ID  
Sent By tgordon Date 2008-11-05 Time 10:09 Rev Time 0.00
Received By rmcdouga Date 2008-10-09 Time 11:17 Sent To  
Notes
2008-10-09 11:16:232004 FBC W/2007 REVISIONS
 ADDITION
  
 DENIED BY BUILDING
  
 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT WILL
 BE REQUIRED. FS 713
  
 2) BEFORE A PERMIT TO CONSTRUCT CAN BE
 ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE PLANS MUST BE
 STAMPED AND THE RECEIPT ATTACHED TO THE
 APPLICATION. 233-5025
  
 3) THE VALUE OF THE PROJECT IS TOO LOW. THE VALUE HAS
 BEEN ADJUSTED TO $ 51,192.00 FOR THE 484 SQUARE FEET
 ADDITION BASED ON ICC VALUATION DATA. ADDITIONAL FEES
 ARE DUE. FBC 108.3
  
 4) SHOW COMPLIANCE WITH R302.1 EXTERIOR WALLS. EXTERIOR
 WALLS SEPARATED BY LESS THAN 6 FEET (1828 MM) SHALL
 HAVE NOT LESS THAN A ONE-HOUR FIRE-RESISTIVE RATING
 WITH EXPOSURE FROM BOTH SIDES. PROJECTIONS SHALL NOT
 EXTEND TO A POINT CLOSER THAN 4 FEET (1220 MM) FROM AN
 ADJACENT PROJECTION OR WALL. THE DISTANCE FROM THE
 ADDITION TO THE PROPERTY LINE IS 5.7' ON ONE SIDE.
 SPECIFY ON THE SITE PLAN/SURVEY THAT THE DISTANCE TO
 THE STRUCTURES ON THE ADJACENT PROPERTY IS GREATER THAN
 SIX FEET.
  
 5) SUBMIT ENERGY CALCULATIONS ON THE PROPER FORM THAT
 HAS BEEN SIGNED BY THE PREPARER AND OWNER/AGENT. MAKE
 THE CORRECTIONS NOTED IN THE MECHANICAL REVIEW NOTES.
 FBC 13-600.
  
 6) SUBMIT PRODUCT APPROVALS FOR THE ROOFING MATERIAL
 FOR THE FLAT ROOF. FAC RULE 9B-72
  
 7) FBC 106.3* CITY AMENDMENTS PRODUCT APPROVALS. THOSE
 PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
  
 8) SUBMIT TWO SETS OF SCALED CONSTRUCTION DRAWINGS WITH
 ALL DIMENSIONS PROVIDED (ROOMS, DOORS,ETC.). FBC *
 106.1.3 CITY AMENDMENTS. QUALITY OF PLANS
 BUILDING PLANS SHALL BE DRAWN TO A MINIMUM 1/8 INCH
 SCALE UPON SUBSTANTIAL PAPER, CLOTH OR OTHER ACCEPTABLE
 MEDIUM. THE BUILDING OFFICIAL MAY ESTABLISH THROUGH
 DEPARTMENTAL POLICY, STANDARDS FOR PLANS AND
 SPECIFICATIONS, IN ORDER TO PROVIDE CONFORMITY TO ITS
 RECORD RETENTION PROGRAM. THIS POLICY MAY INCLUDE SUCH
 THINGS AS MINIMUM SIZE, SHAPE, CONTRAST, CLARITY, OR
 OTHER ITEMS RELATED TO RECORDS MANAGEMENT.
  
 9) SUBMIT PLANS THAT SHOW COMPLIANCE WITH R301.1
 DESIGN. BUILDINGS AND STRUCTURES, AND ALL PARTS
 THEREOF, SHALL BE CONSTRUCTED TO SAFELY SUPPORT ALL
 LOADS, INCLUDING DEAD LOADS, LIVE LOADS, ROOF LOADS,
 FLOOD LOADS AND WIND LOADS AS PRESCRIBED BY THIS CODE.
 THE CONSTRUCTION OF BUILDINGS AND STRUCTURES SHALL
 RESULT IN A SYSTEM THAT PROVIDES A COMPLETE LOAD PATH
 CAPABLE OF TRANSFERRING ALL LOADS FROM THEIR POINT OF
 ORIGIN THROUGH THE LOAD-RESISTING ELEMENTS TO THE
 FOUNDATION.
  
 10) FBC 106.3.5.4 * CITY AMENDMENTS:
 PLAN REVIEW MINIMUM REQUIREMENTS FOR
 PLAN REVIEW, 1 & 2 FAMILY BUILDINGS.
 1) SITE REQUIREMENTS,SET BACK SEPERATION (ASSUMED
 PROPERTY LINE)
 2) FIRE RESISTANT CONSTRUCTION
 (IF REQUIRED)
 3) FIRE
 4)SMOKE DETECTOR LOCATION
 5) EGRESS, EGRESS WINDOW SIZE AND
 LOCATION, STAIR CONSTRUCTION
 REQUIREMENTS
 6) STRUCTURAL REQUIREMENTS SHALL
 INCLUDE:
 FLOOR PLAN, WALL SECTIONS FROM THE
 FOUNDATION, CONTINUOUS LOAD PATH,
 THROUGH THE ROOF, INCLUDING ASSEMBLY
 (PRODUCT APPROVALS) &
 MATERIALS, CONNECTOR TABLES, WIND
 REQUIREMENTS, STRUCTURAL CALCULATIONS (IF REQUIRED)
  
 11) SPECIFY THE APPLICABLE BUILDING CODE AND DESIGN
 STANDARD BEING USED, AS WELL AS, THE WIND SPEED AND
 WIND DESIGN DATA ON THE PLANS. FBC R301.2.1
  
 12) DUE TO THE LARGE AMOUNT OF MISSING INFORMATION ON
 THE PLANS THAT WERE SUBMITTED ADDITIONAL COMMENTS MAY
 RESULT. IT IS RECOMMENDED THAT PLANS FROM A FLORIDA
 LICENSED ARCHITECT OR ENGINEER ARE SUBMITTED FOR THIS
 PROJECT.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2008-11-05 Cont ID  
Sent By rmcdouga Date 2008-11-05 Time 16:16 Rev Time 0.00
Received By rmcdouga Date 2008-10-28 Time 13:33 Sent To  
Notes
2008-11-05 16:17:43OK PER BILL TROBAUGH.

Review Stop E ELECTRICAL
Rev No 1 Status N Date 2008-10-06 Cont ID  
Sent By btrobaug Date 2008-10-06 Time 15:55 Rev Time 0.00
Received By btrobaug Date 2008-10-06 Time 15:20 Sent To M
Notes
2008-10-06 15:55:00 
  
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES:
  
 THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2004
 RESIDENTIAL BUILDING CODE, 2005 NEC, 2004 FBC CHAPTER 1
 AS AMENDED AND FOUND NONCOMPLIANT WITH THE FOLLOWING:
  
 1} THE PERSON TAKING RESPONSIBILITY FOR THE DESIGN MUST
 PRINT AND SIGN THEIR NAME TO SAME PER 106.3.4.2. FBC.
  
 2} PLEASE LOCATE ALL SERVICE EQUIPMENT ON THE PLAN,
 METER ENCLOSURE, DISCONNECTS AND PANELS, SO THAT
 COMPLIANCE WITH ARTICLES 225 AND 230 CAN BE REVIEWED.
  
 3} 0INDICATE IF THE SERVICE SHOWN ON THE ELECTRICAL
 PLAN IS NEW OR EXISTING, IF NEW PER 110.9 AND 110.10:
 OBTAIN THE AVAILABLE FAULT CURRENT AT THE UTILITY AND
 CALCULATE THE SAME AT THE EQUIPMENT. INDICATE THE AIC
 RATING FOR THE EQUIPMENT IS EQUAL TO OR GREATER THAN
 THE AVAILABLE FAULT.
  
 4} R313.1.1 ALTERATIONS, REPAIRS AND ADDITIONS.
 WHEN INTERIOR ALTERATIONS, REPAIRS OR ADDITIONS
 REQUIRING A PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING
 ROOMS ARE ADDED OR CREATED IN EXISTING DWELLINGS, THE
 INDIVIDUAL DWELLING UNIT SHALL BE PROVIDED WITH SMOKE
 ALARMS LOCATED AS REQUIRED FOR NEW DWELLINGS; THE SMOKE
 ALARMS SHALL BE INTERCONNECTED AND HARD WIRED.MAKE A
 NOTE ON THE PLAN INDICATING COMPLIANCE WITH THIS
 ARTICLE.
  
 5} FOR RECORD RETENTION PER 106.5 FBC, AND CLARITY IN
 THE FIELD WHEN WORKING FROM THIS DOCUMENT, PLEASE
 INDICATE THE CODE CYCLES UNDER WHICH THIS PLAN WAS
 DESIGNED.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW.
 CITY OF WEST PALM BEACH
 561/805-6718
 [email protected]
 FAX/:561/805-6676
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2008-12-30 Cont ID  
Sent By adarroug Date 2008-12-30 Time 14:14 Rev Time 0.00
Received By adarroug Date 2008-12-30 Time 14:14 Sent To B
Notes
2008-12-30 14:14:53TO "RMCDOUGAL" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2008-10-24 Cont ID  
Sent By adarroug Date 2008-10-24 Time 14:59 Rev Time 0.00
Received By adarroug Date 2008-10-24 Time 14:59 Sent To Z
Notes
2008-10-24 14:59:29TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-10-06 Cont ID  
Sent By adarroug Date 2008-10-06 Time 09:55 Rev Time 0.00
Received By adarroug Date 2008-10-06 Time 09:55 Sent To E
Notes
2008-10-06 09:55:26TO "SFR" "E"

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-10-09 Cont ID  
Sent By rmcdouga Date 2008-10-09 Time 13:29 Rev Time 0.00
Received By rmcdouga Date 2008-09-30 Time 14:38 Sent To  
Notes
2008-09-30 14:38:24TO "SFR" "Z"

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2008-11-05 Cont ID  
Sent By tgordon Date 2008-11-05 Time 10:09 Rev Time 0.15
Received By tgordon Date 2008-11-05 Time 10:09 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2008-11-05 Cont ID  
Sent By tgordon Date 2008-10-29 Time 11:54 Rev Time 0.30
Received By tgordon Date 2008-10-29 Time 11:54 Sent To B
Notes
2008-10-29 11:56:56PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM
 BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA
 ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES
 (F.S.).
  
 *** DENIED ***
  
 1) AS NOTED IN LAST REVIEW 10-7-08 NOTE #2. WHEN
 RESUBMITTING THE ENERGY CALCULATIONS THEY MUST BE
 SIGNED BY THE PREPARER AND OWNER/AGENT, PER 2004 FBC
 13-103.3.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2008-10-07 Cont ID  
Sent By tgordon Date 2008-10-07 Time 08:42 Rev Time 1.30
Received By tgordon Date 2008-10-07 Time 08:00 Sent To P
Notes
2008-10-07 08:24:50PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM
 BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA
 ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES
 (F.S.).
  
 *** DENIED ***
  
 1) THE ENERGY CALCULATIONS ARE ON THE WRONG FORM,
 PLEASE USE FORM 600C-04 R (SOUTH 7 8 9), PER 2004 FBC
 13-600.3.C.
  
 2) WHEN RESUBMITTING THE ENERGY CALCULATIONS THEY MUST
 BE SIGNED BY THE PREPARER AND OWNER/AGENT, PER 2004 FBC
 13-103.3.
  
 3) THE ENERGY CALCULATIONS ARE MISSING AND OR HAVE
 INCORRECT INFORMATION ON THEM (SEE YELLOW HIGH LIGHTS
 ON THEM), PLEASE CORRECT WHEN RESUBMITTING PER 2004 FBC
 13-103.3.
  
 4) SEE MECHANICAL (A/C) PLAN, SOME OF THE DUCTS (FLEX)
 NEEDS TO BE SIZED (SEE YELLOW HIGH LIGHTS ON PLAN),
 PLEASE CORRECT PER 2004 FBC/R M1601.1.
  
 5) THEIR APPEARS TO BE A MIXING BOX MISSING AT THE
 RETURN AIR DUCTS INTERSECTION PLEASE CHECK PLAN AND
 CORRECT IF NEEDED PER 2004 FBC/R M1601.1.
  
 6) PLEASE SHOW ON MECHANICAL PLAN AND ALL PLANS THE JOB
 ADDRESS, PRINTED NAME OF THE PERSON RESPONSIBLE FOR THE
 DESIGN AND THEIR SIGNATURE, PER 2004 WPB AMEND.
 106.1.3.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]

Review Stop P PLUMBING
Rev No 2 Status P Date 2008-10-28 Cont ID  
Sent By mperson Date 2008-10-28 Time 15:53 Rev Time 0.45
Received By mperson Date 2008-10-28 Time 15:53 Sent To M
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2008-10-08 Cont ID  
Sent By mperson Date 2008-10-08 Time 14:58 Rev Time 1.30
Received By mperson Date 2008-10-08 Time 14:58 Sent To B
Notes
2008-10-08 16:01:37PLUMBING PLAN REVIEW:
 DENIED:
  
 PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH
 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO
 CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE
 (F.A.C.), AND FLORIDA STATUTES (F.S.).
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE.
  
 1. SHEET PLUMBING ISOMETRIC: PLEASE CORRECT THE
 FOLLOWING ITEMS ON THE PLUMBING ISOMETRIC PER THE
 FBC-2004 PLUMBING CODE SECTIONS.
  
 A} THE WASHING MACHINE MUST DRAIN DOWNSTREAM OF THE
 HORIZONTAL WET-VENT BATHROOM GROUP. ONLY FIXTURES
 WITHIN THE TWO BATHROOM GROUPS LOCATED ON THE SAME
 FLOOR SHALL CONNECT TO THE WET-VENTED HORIZONTAL BRANCH
 DRAIN. ANY ADDITIONAL FIXTURES SHALL DISCHARGE
 DOWNSTREAM OF THE WET VENT. PER SECTION 909.1 WET VENT
 PERMITTED.
  
 B} THE WASHING MACHINE TRAP AND FIXTURE DRAIN FOR THE
 AUTOMATIC CLOTHES WASHER SHALL BE A MINIMUM OF 2 INCHES
 (51MM) IN DIAMETER.THE AUTOMATIC CLOTHES WASHER FIXTURE
 DRAIN SHALL CONNECT TO A BRANCH DRAIN OR DRAINAGE STACK
 A MINIMUM OF 3 INCHES (76MM) IN DIAMETER. PER SECTION
 406.3 WASTE CONNECTIONS.
  
 C} A STANDPIPE IS REQUIRED FOR THE WASHING MACHINE AND
 SHALL BE INDIVIDUALLY TRAPPED. STANDPIPES SHALL EXTEND
 A MINIMUM OF 18 INCHES (457MM)
 AND A MAXIMUM OF 42 INCHES (1066MM) ABOVE THE TRAP
 WEIR. ACCESS SHALL BE PROVIDED TO ALL STANDPIPES AND
 DRAINS FOR RODDING. PER SECTION 802.4 STANDPIPES.
  
 D} A CLEANOUT IS REQUIRED FOR THE WASHING MACHINE
 DRAINAGE STACK. THE CLEANOUT SHALL BE 3 INCH (PER
 SECTION 708.7 MINIMUM SIZE) AND IT SHALL BE LOCATED AT
 FOUR FEET ABOVE FINNISH FLOOR (4' A.F.F.) PER SECTION
 708.9 ACCESS.
  
 E} PLEASE KNOW THAT A VENT IS REQUIRED FOR THE WASHING
 MACHINE. PER SECTION 901.2.1 VENTING REQUIRED.
  
 F} PLEASE KNOW THAT WATER-SEAL TRAPS ARE REQUIRED FOR
 THE SHOWER AND DOUBLE LAVATORY AND MUST BE CLEARLY
 INDICATED ON THE RESUBMITTED ISOMETRIC. SECTION 1002.1
 FIXTURE TRAPS.
  
 G} PLEASE CLEARLY INDICATE THE REQUIRED TWO-WAY
 CLEANOUT AT THE JUNCTION OF THE BUILDING DRAIN AND
 BUILDING SEWER. PER SECTION 708.3.5 BUILDING DRAIN AND
 BUILDING SEWER JUNCTION.
  
 2. NOTE: ALL PLANS, SPECIFICATIONS, AND ACCOMPANYING
 DATA BEING FILED FOR PUBLIC RECORD SHALL CONTAIN THE
 PRINTED NAME OF THE RESPONSIBLE PERSON WITH THE
 ORIGINAL SIGNATURE AND DATE ON SUCH INFORMATION. PER
 FBC-2004 CHAPTER 1, (W.P.B. AS AMENDED) SECTION
 *106.3.4.3.
  
 ********IMPORTANT INFORMATION********
 WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE
 OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW
 PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 END OF COMMENTS:
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 PHONE= (561) 805-6730
 FAX= (561) 805-6731
 E-MAIL= [email protected]

Review Stop Z ZONING
Rev No 2 Status P Date 2008-10-28 Cont ID  
Sent By mcruz Date 2008-10-28 Time 11:57 Rev Time 0.00
Received By mcruz Date 2008-10-28 Time 11:57 Sent To E
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2008-10-04 Cont ID  
Sent By mcruz Date 2008-10-04 Time 15:05 Rev Time 0.00
Received By mcruz Date 2008-10-04 Time 15:01 Sent To I
Notes
2008-10-04 15:04:53***ZONING FAILED***
  
 1. PLEASE PROVIDE ALL RESPONSES IN WRITING.
  
 2. INDICATE OVERHANG DIMENSIONS OF THE PROPOSED
 ADDITION. PURSUANT TO THE ZONING AND LAND DEVELOPMENT
 REGULATIONS (ZLDR), SECTION 94-305(B): OVERHANGS SHALL
 NOT PROJECT MORE THAN THREE (3) FEET INTO A REQUIRED
 SETBACK.
  
 3. INDICATE THE SEPARATION DISTANCE OF THE PROPOSED
 ADDITION TO THE EXISTING SHED. NOTE: PURSUANT TO THE
 ZLDR, SECTION 94-304(B)(3): ACCESSORY STRUCTURES SHALL
 BE LOCATED NO CLOSER THAN SIX (6) FEET TO THE PRINCIPAL
 STRUCTURE.
  
 4. INDICATE THE HEIGHT OF THE PROPOSED ADDITION.
  
 NOTE: THE SUBMITTAL OF THE REQUESTED INFORMATION MAY
 GENERATE ADDITIONAL COMMENTS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO
 CONTACT ME.
  
 MAGGIE CRUZ, ASSOCIATE PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: (561) 822-1444 OR (561) 805-6720
 E-MAIL: [email protected]
  