| Plan Review Stops For Permit 08090577 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2008-12-10 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-12-10 |
Time |
08:01 |
Rev Time |
0.33 |
| Received By |
jwitmer |
Date |
2008-12-10 |
Time |
08:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2008-11-04 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-11-04 |
Time |
13:40 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2008-11-04 |
Time |
13:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-10-09 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-10-09 |
Time |
13:35 |
Rev Time |
1.55 |
| Received By |
jwitmer |
Date |
2008-10-09 |
Time |
13:28 |
Sent To |
|
|
| Notes |
| 2008-10-09 13:52:49 | BUILDING PLAN REVIEW | | | PERMIT: 08090577 | | | ADD: 5500 VILLAGE BLVD | | | CONT: PRESIDENTIAL CONSTRUCTION | | | TEL: (561)723-3370 | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW | | | ACTION: DENIED | | | | | | | | | | | | 1A) INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE | | | INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | 1B) INFORMATIONAL FL S S 713.13 NOTICE OF COMMENCEMENT, | | | TO BE FILED WITH THE CLERK OF THE COURT. NOTE: | | | 713.13(2) IF THE WORK DESCRIBED IN THE NOTICE OF | | | COMMENCEMENT IS NOT ACTUALLY COMMENCED WITHIN 90 DAYS | | | AFTER THE RECORDING THEREOF, SUCH NOTICE IS NULL & | | | VOID. NOTE: 713.13(6) THE POSTING OF THE NOTICE OF | | | COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE THE FIRST | | | INSPECTION. | | | | | | 2) 61G1-16.004 FL. ADMIN. CODE. PLANS PREPARED BY A | | | REGISTERED ARCHITECT SHALL INCLUDE A TITLE BLOCK WHICH | | | MUST: | | | - INCLUDE AN ORIGINAL SIGNATURE AND DATED SEALED | | | INCLUDE THE PRINTED NAME OF THE ARCHITECT SEALING THE | | | PLANS | | | | | | 3) SHEET A-2 DOOR B IS MISSING THE REQUIRED 18" ON THE | | | PULL SIDE OF THE PULL SIDE OF DOOR. 11-4.13.6 | | | MANEUVERING CLEARENCES, AT DOORS. MINIMUM MANEUVERING | | | CLEARANCES | | | AT DOORS THAT ARE NOT AUTOMATIC OR POWER-ASSISTED SHALL | | | BE AS SHOWN IN FIG. 25. THE FLOOR OR GROUND AREA WITH | | | IN THE REQUIRED CLEARANCES SHALL BE CLEAR & LEVEL. | | | | | | 4) SHEET A-4 DETAIL BREAK ROOM ELEVATION INDICATES | | | DOORS ON THE SINK BASE UNIT. SINKS: | | | 11-4.24.2 SINKS, HEIGHT. SINKS SHALL BE MOUNTED WITH | | | THE COUNTER NO HIGHER THAN 34" ABOVE THE FINISH FLOOR. | | | 11-4.24.3 KNEE CLEARANCE THAT IS AT LEAST 27" HIGH 30" | | | WIDE, AND 19" DEEP SHALL BE PROVIDED UNDERNEATH SINKS. | | | 11-4.24.5 CLEAR FLOOR SPACE. A CLEAR FLOOR SPACE AT | | | LEAST 30 INCHES BY 48 INCHES (760 MM BY 1219 MM) | | | COMPLYING WITH | | | SECTION 11-4.2.4 SHALL BE PROVIDED IN FRONT OF A SINK | | | TO ALLOW FORWARD APPROACH. | | | THE CLEAR FLOOR SPACE SHALL BE ON AN ACCESSIBLE ROUTE | | | AND SHALL EXTEND A MAXIMUM OF 19 INCHES (485 MM) | | | UNDERNEATH THE SINK. | | | | | | 5) THE COVERSHEET LIST THIS AS A TYPE III-B FULLY | | | SPRINKLERED BUILDING WHERE AS THE LS -1 INDICATES THE | | | BUILDING TO BE A V-B FULLY SPRINKLERED BUILDING. PLEASE | | | COORDINATE PLANS TO A MINIMUM | | | BUILDING TYPE. TABLE 503 & TABLE 601. | | | | | | 6) GONZALEZ & GONZALEZ ENGINEERING, INC IS MISSING | | | THEIR CERTIFICATE OF AUTHORIZATION. | | | 471.023 F.S. CERTIFICATE OF AUTHORIZATION. THE TITLE | | | BLOCK FOR ANY SHEET BEARING THE NAME OF AN ENGINEER | | | PRACTICING UNDER A FICTITIOUS NAME, A CORPORATION, OR A | | | PARTNERSHIP, OFFERING ENGINEERING SERVICES, SHALL | | | INCLUDE THE CERTIFICATE OF AUTHORIZATION NUMBER. ADD | | | THE NUMBER TO EACH SHEET. THIS MAY BE ADDED BY HAND. | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2008-12-13 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-12-13 |
Time |
10:13 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-12-13 |
Time |
10:11 |
Sent To |
M |
|
| Notes |
| 2008-12-13 10:12:55 | METHOD B ENERGY CALCULATIONS REMOVED FROM PERMIT | | | APPLICATION. COMPLIANCE WITH 400C PRESCRIPTIVE | | | REQUIREMENTS DEMONSTRATED ON PLANS. OK PER DVP. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2008-12-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-12-05 |
Time |
13:06 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-12-05 |
Time |
13:06 |
Sent To |
|
|
| Notes |
| 2008-12-05 13:06:38 | | | | ** FAILED/TEMPORARY** | | | | | | | | | | | | 1) NOTE: PLEASE SEE FBC 13-415.2.ABC.1. THE FOLLOWING | | | IS EXTRACTED DIRECTLY FROM THE FLORIDA BUILDING CODE. | | | ** | | | **TRADE-OFFS OF INTERIOR LIGHTING POWER ALLOWANCE AMONG | | | PORTIONS OF THE BUILDING FOR WHICH A DIFFERENT METHOD | | | OF CALCULATION HAS BEEN USED ARE NOT PERMITTED.** | | | AS THE PLANS SUBMITTED INDICATE METHOD *C* AND THE | | | FLA-COM BEING SUBMITTED IS METHOD*B* THIS A CLEAR | | | CONFLICT WITH THE CODE SECTION AS NOTED ABOVE. | | | THE MINIMUM PRESCRIPTIVE REQUIREMENTS FOR LIGHTING | | | PERFORMANCE IS SHOWN ON ELECTRICAL PLANS ARE IS OK. | | | HOWEVER THE FLA-COM B MAY NOT BE USED IN CONJUNCTION. | | | PLEASE SEE SECTION 202 FOR DEFINITIONS OF A RENOVATION | | | AND SECTION 13-400.0.C.4. THE FOLLOWING IS EXTRACTED | | | DIRECTLY FROM THE LATEST REVISIONS WHICH ARE ADOPTED IN | | | THE 2004 FBC. | | | | | | 13-400.0.C.4 RENOVATED BUILDINGS. | | | RENOVATED BUILDINGS SHALL, WHEN APPLICABLE (SEE SECTION | | | 202), MEET THE EFFICIENCIES LISTED ON FORM 400C FOR | | | COMPONENTS BEING CHANGED OR SHALL COMPLY WITH THE | | | ENVELOPE OR SYSTEMS CRITERIA IN METHOD B OF FLA/COM FOR | | | THE COMPONENTS BEING CHANGED. EXISTING BUILDINGS NOT | | | MEETING THE DEFINITION OF A RENOVATION IN WHICH NEW | | | HEATING, COOLING, WATER HEATING, ELECTRICAL OR LIGHTING | | | SYSTEMS ARE INSTALLED SHALL MEET THE BASIC PRESCRIPTIVE | | | MINIMUM EFFICIENCIES LISTED IN THIS CODE FOR THE | | | SYSTEM(S) BEING CHANGED. | | | 13-400.1 PRESCRIPTIVE REQUIREMENTS. | | | BASIC PRESCRIPTIVE REQUIREMENTS SHALL BE MET FOR ALL | | | BUILDINGS. THE SECTION NUMBER FOLLOWED BY THE COMBINED | | | NUMBER AND LETTERS ?.1.ABC? INDICATES THESE BASIC | | | PRESCRIPTIVE REQUIREMENTS (I.E., PRESCRIPTIVE | | | REQUIREMENTS THAT SHALL BE MET BY BUILDINGS COMPLYING | | | BY EITHER METHOD A, B, OR C) IN SECTIONS 401 THROUGH | | | 415. PRESCRIPTIVE REQUIREMENTS SPECIFIC TO METHOD A, B, | | | OR C (I.E. ?.1.B? IS SPECIFIC TO METHOD B) SHALL BE MET | | | WHEN COMPLYING WITH THE CODE BY THAT METHOD. WHERE A | | | PRESCRIPTIVE REQUIREMENT SPECIFIC TO A METHOD IS MORE | | | STRINGENT THAN THE BASIC PRESCRIPTIVE REQUIREMENT, THE | | | MORE STRINGENT REQUIREMENT SHALL BE MET. | | | | | | | | | ** UPON READING SECTION 202 OF THE FBC CHAPTER 13 | | | DEFINITIONS YOU WILL BE ABLE TO UNDERSTAND HOW THIS IS | | | NOT A RENOVATED BUILDING BY THE DEFINITION. | | | | | | A CALL WAS PLACED TO THE ARCHITECT OF RECORD AND A | | | MESSAGE WAS LEFT ON VOICE-MAIL. A CALL WAS ALSO PLACED | | | TO MR. TIM CROWLEY OF PRESIDENTIAL CONSTRUCTION TO | | | INFORM OF THE DISCREPANCIES. | | | | | | | | | PLEASE CALL AS SOON AS POSSIBLE TO GO OVER FOR | | | ACCEPTABLE FORM FOR OTHER TRADES. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2008-11-06 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-11-06 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-11-06 |
Time |
11:49 |
Sent To |
|
|
| Notes |
| 2008-11-06 11:49:29 | | | | | | | | | | ** DENIED 2ND REVIEW ** | | | | | | 1) NOTE: ELECTRICAL PLANS NEED TO SHOW THE CIRCUITING | | | OF EMERGENCY AND EXIT LIGHTS PER 700.12F. RESPONSE | | | MENTIONS TO SEE NOTES ON THE LIFE SAFETY PLANS HOWEVER | | | AS THE PLANS NEED TO SHOW THE CIRCUITING YOU MAY NOT | | | QUOTE THE CODE IN LIEU OF SPECIFIC DETAIL. | | | | | | 2) NOTE: PLEASE SEE THE PREVIOUS REVIEW WITH RESPECT TO | | | THE LIGHTING PERFORMANCE CALCULATIONS. IN THE REVIEW | | | COMMENTS IT STATED TO PLEASE CALL TO GO OVER HOW TO | | | SHOW. THE PLANS SHOW CALCULATIONS BASED ON TABLE | | | 13-415.2.C WHICH ARE OK HOWEVER THERE ARE ADDITIONAL | | | FIXTURES ON PLANS NOT FIGURED INTO THE CALCULATIONS. | | | (RECESSED FIXTURES). | | | PLEASE SEE THE PACKAGE ALSO SUBMITTED A FORM B, WHICH | | | BY DEFINITION THIS IS NOT A RENOVATION MEETING SECTION | | | 202. THE COMPLIANCE METHOD SHOWN ON PLANS IS OK BUT | | | PLEASE ADJUST THE NUMBER OF FIXTURES. | | | | | | 3) NOTE: PLEASE SEE SOME AREAS ARE STILL MISSING | | | REQUIRED LIGHTING CONTROLS PER | | | 13-415.1.ABC.1.1,.1.2,.1.3. SEE ROOM 117 FOR EXAMPLE | | | WHICH STILL INDICATES STAND SWITCHES. | | | PLEASE ALSO EXPLAIN THE NUMEROUS SWITCHES IN ROOM 100. | | | AN OCCUPANT MUST BE ABLE TO SEE ALL LIGHTING WHICH IS | | | BEING CONTROLLED OR MEET THE EXCEPTIONS IN THE SECTIONS | | | GIVEN. | | | PLEASE CALL TO GO OVER. | | | | | | 4) NOTE: PLEASE SEE 230.2,230.2E ETC. PLEASE IDENTIFY | | | ALL SERVICE EQUIPMENT. THE RISER AND LAYOUT IS NOT | | | INFORMATIVE ENOUGH TO GRANT AN ADDITIONAL MAIN TO THE | | | TENANT SPACE WHICH ALREADY CONTAINS ELECTRICAL SERVICE. | | | WHAT IS THE VOLTAGE OF NEW? | | | 200,201 INDICATES 120/240V. | | | FINAL DETERMINATION CAN NOT BE MADE AT THIS TIME. | | | PLEASE SEE 220.87,215.5,215.3,230.42 ETC | | | | | | | | | **IMPORTANT** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED | | | INTO TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2008-10-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-10-09 |
Time |
08:39 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-10-09 |
Time |
08:39 |
Sent To |
|
|
| Notes |
| 2008-10-09 08:39:41 | | | | ** DENIED ** | | | | | | 1) NOTE: PLEASE SEE THE SUBMITTED METHOD *A* ENERGY | | | CALCULATIONS MAY NOT BE USED. THIS IS FOR A TENANT | | | SPACE WITHIN A BUILDING. THE METHOD *A* BY DEFINITION | | | IS FOR A *WHOLE BUILDING* WHICH THIS IS NOT. | | | PLEASE SEE 13-101.1. | | | PLEASE BE SURE TO SEE FBC 13-415.2, | | | 13-415.2.ABC.1.1,.1.2, TABLE 13-415.2.B., 13-415.2.C. | | | PLEASE CALL TO GO OVER HOW PRESCRIPTIVE REQUIREMENTS | | | CAN BE MET. | | | THE SUBMITTED CALCULATIONS DO NOT CONTAIN ANY SEAL. | | | THEY ALSO CONTAIN A PRINTED NAME OF THE PERSON | | | PREPARING THE DOCUMENTS OTHER THAN THE LICENSED | | | ARCHITECT OR ENGINEER. | | | | | | 2) NOTE: PLEASE SEE MISSING TITLE BLOCK INFORMATION FOR | | | GONZALES AND GONZALES ENGINEERS INC. PLEASE SEE THESE | | | ARE MISSING THE REQUIRED ENGINEERING BUSINESS LICENSE | | | NUMBER WHICH IS ALSO KNOWN AS A CERTIFICATE OF | | | AUTHORIZATION NUMBER PER FS 471.023, FAC 61G15-23.002. | | | | | | 3) NOTE: NEW SERVICE AS SHOWN NOT GRANTED PER 230.2. | | | PLEASE RE-WORK RISER AND UPGRADE EXISTING AS NEEDED. | | | AS PROPOSED SERVICE IS NOT GRANTED NO REVIEW FOR NEW | | | SHOWN WAS DONE. | | | PLEASE ALSO SEE THE CODE AS THE RISER DOES SHOW | | | ELECTRICAL FROM SEPARATE SERVICES INTO THE SAME | | | JUNCTION BOXES WHICH IS NOT PERMITTED. | | | | | | 4) NOTE: ACCESS CONTROLS AS NOTED ON PLANS WILL BE | | | REQUIRED TO BE UNDER A SEPARATE PERMIT APPLICATION | | | ALONG WITH PLANS DETAILING ALL SYSTEM PER NFPA-101 | | | CHAPTER 7 FOR ACCESS CONTROLS, EGRESS ETC. | | | EGRESS UNDER NORMAL OR EMERGENCY CONDITIONS SHALL NOT | | | BE IMPEDED. | | | | | | 5) NOTE: PLEASE SEE FBC 11-4.27.4 | | | CONTROLS AND OPERATING MECHANISMS SHALL BE OPERABLE | | | WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, | | | PINCHING, OR TWISTING OF THE WRIST. THE FORCE REQUIRED | | | TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 LBF | | | (22.2 N). | | | | | | 6) NOTE: PLEASE PROVIDE A BASE DESIGN DETAIL FOR | | | OCCUPANCY SENSORS AND CONTROLS. WILL THIS BE A LOW | | | VOLTAGE SYSTEM? LINE VOLTAGE SYSTEM? ETC | | | PLEASE KNOW THE DEVICES USED IN AREAS SUCH AS THE | | | MULTI-STALL RESTROOM SHALL BE ULTRASONIC/DUAL | | | TECHNOLOGY. | | | 13-415.1.ABC.1.1,.1.2 | | | | | | 7) NOTE: PLEASE INDICATE ALL EMERGENCY AND EXIT | | | LIGHTING TO THE LOCAL BRANCH CIRCUIT PER 700.12F. | | | | | | | | | | | | | | | | | | | | | | | | **IMPORTANT** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | | TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANOR PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2008-12-11 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-12-11 |
Time |
13:28 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-12-11 |
Time |
13:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2008-11-10 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-11-10 |
Time |
11:27 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-11-10 |
Time |
11:27 |
Sent To |
|
|
| Notes |
| 2008-11-10 11:28:31 | PLANS STAMPED SEPARATE SHOP DRAWINGS AND PERMIT | | | REQUIRED FOR FIRE ALARM REMODEL. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2008-10-21 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-10-21 |
Time |
14:26 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-10-21 |
Time |
14:26 |
Sent To |
|
|
| Notes |
| 2008-10-21 14:39:34 | ***DENIED*** | | | | | | 1) CLASSIFICATION OF RATED DOORS SHALL BE EXPRESSED IN | | | HOURS OR FRACTIONS PER NFPA 80, SEC. 4.1.1. | | | | | | 2) DUCT SMOKE DETECTORS SHALL INITATE A GENERAL FIRE | | | ALARM IN ACCORDANCE WITH LOCAL REQUIREMENTS. | | | | | | 3) IN ADDITION TO SHOP DRAWINGS AND PERMIT, FIRE | | | SPRINKLER HEAD LAYOUT FOR COMMERCIAL PROJECTS SHALL BE | | | PROVIDED PER FBC 106. HEAD LAYOUT MAY BE SHOWN ON | | | REFLECTED CEILING PLAN. | | | | | | 4) SEPARATE SHOP DRAWINGS AND PERMIT REQUIRED FOR | | | ACCESS CONTROL SYSTEM THAT SHALL COMPLY WITH NFPA 101, | | | SEC. 7.2.1.6.2. | | | | | | | | | MIKE WENNERGREN, ASST. FIRE MARSHAL | | | FIRE PLAN REVIEW | | | FIRE PREVENTION (561) 804-4756 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-11-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-11-18 |
Time |
16:52 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-11-18 |
Time |
16:52 |
Sent To |
|
|
| Notes |
| 2008-11-18 16:54:59 | TO "COMM" BD#49 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-10-31 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-10-31 |
Time |
13:48 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-10-31 |
Time |
13:48 |
Sent To |
|
|
| Notes |
| 2008-10-31 13:48:20 | TO "COMM" BD#56 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-10-21 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-10-21 |
Time |
14:51 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-09-24 |
Time |
11:57 |
Sent To |
|
|
| Notes |
| 2008-09-24 12:00:28 | TO "COMM" BD#35 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2009-02-17 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-02-17 |
Time |
18:02 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-02-17 |
Time |
18:02 |
Sent To |
PC |
|
| Notes |
| 2009-02-17 18:02:35 | REVISED M-3 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2008-12-13 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-12-13 |
Time |
10:11 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-12-13 |
Time |
10:11 |
Sent To |
PC |
|
| Notes |
| 2008-12-13 10:15:07 | FORM 400B CALCULATIONS REMOVED FROM APPPLICATION. FORM | | | 400C PRESCRIPTIVE REQUIREMENTS ARE DEMONSTRATED ON | | | PLANS, WITH SEPARATE COOLING LOAD CALCS, MEETING THE | | | REQUIREMENTS FOR FBC CHAPTER 13 COMPLIANCE. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2008-11-03 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-11-03 |
Time |
10:05 |
Rev Time |
2.00 |
| Received By |
tgordon |
Date |
2008-11-03 |
Time |
09:35 |
Sent To |
|
|
| Notes |
| 2008-11-03 10:05:12 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | *** DENIED *** | | | | | | 1) THE RESPONSE TO REVIEW NOTES FROM 10-1-08 SYSTEM | | | SIZING, ADDRESSES SENSIBLE LOADS. THE 2004 FBC DOES NOT | | | ADDRESS SENSIBLE LOAD ONLY TOTAL LOADS, AS THE COOLING | | | LOAD CALCULATIONS SUBMITTED SHOWS TOTAL COOLING | | | REQUIRED IS BASED ON TOTAL LOAD. IF YOU WISH TO | | | ENGINEER THE A/C SYSTEMS TO YOUR REQUIREMENTS PLEASE | | | COMPLY WITH 2004 FBC 13-407.1.ABC.1 " EXCEPTIONS" A | | | SUMMARY SHEET MAY BE SUBMITTED WHEN SIGNED AND SEALED | | | BY THE ENGINEER AND HAS THE MINIMUM INFORMATION ON IT. | | | **PROJECT NAME/OWNER... **PROJECT ADDRESS... **SIZING | | | METHOD USED... **AREA IN SQUARE FEET... **OUTDOOR DRY | | | BULB USED... **OUTDOOR WET BULB USED... **RELATIVE | | | HUMIDITY... **INDOOR DRY BULB.... **TOTAL HEATING | | | REQUIRED WITH OUTSIDE AIR... **TOTAL SENSIBLE GAIN... | | | **TOTAL LATENT GAIN... **GRAINS WATER (DIFFERENCE)... | | | **TOTAL COOLING REQUIRED WITH OUTSIDE AIR. (PLEASE HAVE | | | THE TOTAL COOLING OF THE SUMMARY ADDRESS THE TOTAL | | | COOLING OF THE SYSTEMS ON THE PLANS). | | | | | | 2) SYSTEMS 1, 2, 3, 4, 6, 7, 8, AND 9 ARE OVER SIZED | | | PER COOLING LOAD CALCULATIONS SUBMITTED. PER 2004 FBC | | | 13-407.1.ABC.1.1 HVAC SYSTEMS AND EQUIPMENT SHALL BE | | | SIZED TO PROVIDE NO MORE THAN THE SPACE AND SYSTEM | | | LOADS CALCULATED IN ACCORDANCE WITH SECTION | | | 407.1.ABC.1. A SINGLE PIECE OF EQUIPMENT PROVIDING BOTH | | | COOLING AND HEATING SHALL SATISFY THIS PROVISION WHEN | | | THE COOLING FUNCTION MEETS THE PROVISIONS OF SECTION | | | 407.1.ABC.1, AND THE HEATING FUNCTION IS SIZED AS SMALL | | | AS POSSIBLE TO MEET THE LOAD WITHIN AVAILABLE EQUIPMENT | | | OPTIONS. | | | | | | 3) REVISED ENERGY CALCULATIONS SUBMITTED ARE NOT | | | LISTING SYSTEMS 1, 2, 3, 4, AND 9. ALSO THE INPUT DATA | | | REPORT SUBMITTED IS MISSING SYSTEMS 1, 2, 8, AND 9. | | | PLEASE CORRECT PER 2004 FBC 13-103.3. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2008-10-01 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-10-01 |
Time |
16:04 |
Rev Time |
1.45 |
| Received By |
tgordon |
Date |
2008-10-01 |
Time |
16:04 |
Sent To |
|
|
| Notes |
| 2008-10-01 16:28:06 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | *** DENIED *** | | | 1) COOLING LOAD CALCULATIONS SHOW ZONE #5 NEEDS 8,876 | | | TOTAL COOLING BTU'S, MECHANICAL PLAN M-1 IS SHOWING | | | SYSTEM #5 AS 24,500 (2 TON) TOTAL COOLING BTU'S. A 1.5 | | | TON SYSTEM WOULD MEET THE COOLING LOAD REQUIREMENTS, | | | SEE 2004 FBC 13-407.1.ABC.1.1. PLEASE COMPLY. | | | | | | 2) COOLING LOAD CALCULATIONS SHOW ZONE #6 NEEDS 15,670 | | | TOTAL COOLING BTU'S, MECHANICAL PLAN M-1 IS SHOWING | | | SYSTEM #6 AS 59,700 (5 TON) TOTAL COOLING BTU'S. A 1.5 | | | TON SYSTEM WOULD MEET THE COOLING LOAD REQUIREMENTS, | | | SEE 2004 FBC 13-407.1.ABC.1.1. PLEASE COMPLY. | | | | | | 3) ONLY ONE SET OF THE COOLING LOAD CALCULATIONS WERE | | | SUBMITTED, PLEASE SUBMIT TWO SETS, PER 2004 WPB AMEND. | | | 106.1. | | | | | | 4) PLAN M-3 RETURN AIR DUCTS (FLEX) NEEDS TO BE SIZED | | | IN ROOMS 117, 116, 113.112 AND 102. A SUPPLY AIR DUCT | | | IN FILE AREA 111 NEEDS TO BE SIZED ALSO (SEE YELLOW | | | HIGH LIGHT ON PLAN). PLEASE CORRECT PER 2004 FBC/M | | | 603.2. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2008-11-14 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-11-14 |
Time |
08:52 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-11-14 |
Time |
08:52 |
Sent To |
|
|
| Notes |
| 2008-11-14 08:54:50 | | | | | | | PASSED/PROVISO: | | | | | | SECTIONS | | | 11-4.24.4 SINK DEPTH | | | 11-4.24.5 CLEAR FLOOR SPACE (FIG. 32) | | | 11-4.16.5 FLUSH CONTROLS | | | 604.9 W.H.A AT ICE MAKER IN REF. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2008-09-26 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-09-26 |
Time |
15:47 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-09-26 |
Time |
10:31 |
Sent To |
|
|
| Notes |
| 2008-09-26 15:47:16 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 11 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1. ALL SHEETS. THE TITLE BLOCK SHALL CONTAIN THE | | | ADDRESS AND PHONE NUMBER OF THE ARCHITECT. FAC | | | 61B1-16.004(1) & FS 481.2055. | | | | | | 2. SUBMIT DETAILS FOR THE ACCESSIBLE WATER CLOSETS, | | | LAVS & BREAK ROOM SINK. PLEASE SHOW COMPLIANCE WITH THE | | | FOLLOWING: | | | | | | ___FOR W/C'S: | | | A. 11-4.16.2 CLEAR FLOOR SPACE | | | B. 11-4.16.3 HEIGHT | | | C. 11-4.16.4 GRAB BARS (SHT A-2 REFERENCE NOTES 1 & 2 | | | INDICATE THE WRONG LENGTHS FOR THE BARS FOR THE BACK | | | WALL AND THE SIDE WALL). | | | D. 11-4.16.5 FLUSH CONTROLS | | | E. 11-4.16.6 DISPENSERS | | | | | | ___FOR LAVS: | | | A. 11-4.19.2 HEIGHT & CLEARANCES | | | B. 11-4.19.3 CLEAR FLOOR SPACE | | | C.11-4.19.4 EXPOSED PIPES & SURFACES | | | D. 11-4.19.5 FAUCETS | | | E. 11-4.19.6 MIRRORS | | | | | | ___FOR SINKS: | | | A. 11-4.24.3 KNEE CLEARANCE | | | B. 11-4.24.4 SINK DEPTH | | | C. 11-4.24.5 CLEAR FLOOR SPACE | | | D. 11-4.24.6 EXPOSED PIPES & SURFACES | | | E. 11-4.24.7 FAUCETS | | | F. 11-4.2.3 TURNING AREA IN BREAK ROOM | | | | | | 3. SHT P.1 SANITARY RISER INDICATES A DRY HORIZONTAL | | | VENT. THIS IS NOT APPROVED PER SECTION 905.3. | | | | | | 4. SHT P.1 WATER RISER DOES NOT INDICATE THE NEW BREAK | | | ROOM SINK. PLEASE SUBMIT A RISER THAT REFLECT THE FLOOR | | | PLAN. SECTIONS 106.1.1 & 604. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | | | | | | | | | | |
|
|