Plan Review Details - Permit 08090511
Plan Review Stops For Permit 08090511
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2009-04-16 Cont ID  
Sent By shill Date 2009-04-16 Time 11:39 Rev Time 0.00
Received By shill Date 2009-04-16 Time 11:39 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2008-12-22 Cont ID  
Sent By shill Date 2008-12-22 Time 11:51 Rev Time 0.00
Received By shill Date 2008-12-22 Time 11:51 Sent To  
Notes
2008-12-22 11:56:26****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FAC FLORIDA ADMINISTRATIVE CODE
 FS FLORIDA STATUTE
  
  
 1. PROVIDE TWO IDENTICAL COLLATED SETS OF DOCUMENTS FOR
 PERMIT ISSUANCE FBC*106. OLD SHEETS SHOULD BE MARKED
 "VOID" AND SUBMITTED SEPARATELY FOR REFERENCE. I CANNOT
 DETERMINE WHICH DOCUMENTS ARE TO BE INCLUDED IN THIS
 REVIEW AND WHICH ARE OLD SHEETS. I CANNOT LOCATE TWO
 SETS OF ALL DOCUMENTS IN THE PACKAGE SUBMITTED.
  
 2. PROVIDE THE TOTAL VALUATION INCLUDING THE GENERATOR.
  
 3. SEE PREVIOUS LIST REGARDING REQUIREMENT FOR
 DOCUMENTS PREPARED BY AN ENGINEER TO BE SIGNED, SEALED
 DATED ORIGINALS FS471.
  
 4. ALL STRUCTURAL DETAILS ARE TO INCLUDE WIND DESIGN
 CRITERIA FBC R301, FBC1603.1.4. IF THE DOCUMENT IS NOT
 PREPARED BY A DESIGN PROFESSIONAL, THE PERSON TAKING
 RESPONSIBILITY FOR THE DESIGN IS TO PROVIDE HIS/HER
 SIGNATURE FBC*106.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-10-09 Cont ID  
Sent By shill Date 2008-10-09 Time 08:53 Rev Time 0.00
Received By shill Date 2008-10-09 Time 08:53 Sent To  
Notes
2008-10-09 09:01:54****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FAC FLORIDA ADMINISTRATIVE CODE
 FS FLORIDA STATUTE
  
 1. DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED FOR
 PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED ORIGINALS
 FAC61G15-23.002 (PROPANE TANK HOLDDOWN DETAIL).
  
 2. THE PROPANE TANK HOLDDOWN DETAIL SHOULD INCLUDE WIND
 DESIGN CRITERIA, FBC R 301 (WIND SPEED, EXPOSURE).
  
 3. PROVIDE A STRUCTURAL DETAIL FOR THE GENERATOR SLAB,
 FBC R 301. IF A PREFAB SLAB IS USED,
 ENGINEERING/CALCULATIONS ARE REQUIRED TO SHOW THAT WIND
 LOADS WILL BE RESISTED.
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2009-03-03 Cont ID  
Sent By btrobaug Date 2009-03-03 Time 12:11 Rev Time 0.00
Received By btrobaug Date 2009-03-03 Time 11:45 Sent To G
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2008-12-11 Cont ID  
Sent By btrobaug Date 2008-12-11 Time 09:42 Rev Time 0.00
Received By btrobaug Date 2008-12-10 Time 16:37 Sent To G
Notes
2008-12-11 09:42:25 
  
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES:
  
 THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2004
 RESIDENTIAL BUILDING CODE, 2005 NEC, 2004 FBC CHAPTER 1
 AS AMENDED AND FOUND NONCOMPLIANT WITH THE FOLLOWING:
 COMMENT FROM PREVIOUS REVIEW
  
 1} PLEASE LOCATE ALL SERVICE AND GENERATOR EQUIPMENT ON
 A SITE PLAN, NOT THE SURVEY, METER ENCLOSURE,
 DISCONNECTS, ATS AND PANELS, SO THAT COMPLIANCE WITH
 ARTICLES 225 AND 230 CAN BE REVIEWED.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2008-09-30 Cont ID  
Sent By btrobaug Date 2008-09-30 Time 16:17 Rev Time 0.00
Received By btrobaug Date 2008-09-30 Time 15:41 Sent To M
Notes
2008-09-30 16:16:57 
  
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES:
  
 THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2004
 RESIDENTIAL BUILDING CODE, 2005 NEC, 2004 FBC CHAPTER 1
 AS AMENDED AND FOUND NONCOMPLIANT WITH THE FOLLOWING:
  
 1} PLEASE LOCATE ALL SERVICE AND GENERATOR EQUIPMENT ON
 A SITE PLAN, NOT THE SURVEY, METER ENCLOSURE,
 DISCONNECTS, ATS AND PANELS, SO THAT COMPLIANCE WITH
 ARTICLES 225 AND 230 CAN BE REVIEWED.
  
 2} THE RISER DIAGRAM INDICATES THE CONDUIT FROM THE
 METER TO THE ATS IS NOT USED. IT IS NOT CLEAR HOW THE
 ATS WILL RECEIVE NORMAL POWER. IF FROM THE 200 AMP
 PANEL, INDICATE THE NUMBER OF CONDUCTORS FROM THAT
 PANEL TO THE JUNCTION BOX (3 SHOWN) THEN THERE WOULD BE
 SIX , 3 TO AND 3 FROM (PLUS EQUIPMENT GROUND) THE
 ATS.215.5.
  
 3} THE DIAGRAM ALSO INDICATES 3-#4 CONDUCTORS FEEDING
 THE 200 AMP PANEL FROM THE METER. INDICATE THE SIZE OF
 THE MAIN OCP IN THE 200 AMP PANEL. 215.5, 310.16.
 INDICATE IF THE SERVICE, OR WHICH PARTS, ARE NEW AND
 WHICH ARE EXISTING.
  
 4} IF THE SERVICE IS 200 AMP THE GEC REQUIRED PER
 250.66 DOES NOT COMPLY.
  
 5} INDICATE THAT THE LOAD CALCULATION GIVEN IS FOR THE
 GENERATOR PANEL THE CALCULATION SHEET. LABEL PANELS
 ACCORDINGLY.
  
 6} PROVIDE MANUFACTURERS SPECIFICATIONS FOR THE
 GENERATOR INDICATING RECOMMENDED SETBACKS FROM
 STRUCTURES.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
  

Review Stop G GAS REVIEW
Rev No 3 Status P Date 2009-03-18 Cont ID  
Sent By kstevens Date 2009-03-18 Time 16:41 Rev Time 0.00
Received By kstevens Date 2009-03-18 Time 16:41 Sent To M
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 2 Status F Date 2008-12-11 Cont ID  
Sent By kstevens Date 2008-12-11 Time 15:25 Rev Time 0.00
Received By kstevens Date 2008-12-11 Time 15:25 Sent To M
Notes
2008-12-11 16:50:20GAS PLAN REVIEW:
 DENIED:
  
 PLAN REVIEW UNDER THE 200R FLORIDA BUILDING CODES WITH
 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO
 CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE
 (F.A.C.), AND FLORIDA STATUTES (F.S.).
  
 SECOND REVIEW:
 ****FROM PREVIOUS REVIEW:
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 GAS PLAN REVIEW TO MEET CODE COMPLIANCE.
  
 1. THE SUBMITTED GAS SITE AND ISOMETRIC RISER DIAGRAM
 ARE INDICATING THE PLAN SHEET TO BE COMPLIANT WITH THE
 "SOUTH FLORIDA BUILDING CODE 2004". PLEASE KNOW THAT
 THE SOUTH FLORIDA BUILDING CODE WAS FOR THE MIAMI-DADE
 AND BROWARD COUNTIES. ALSO PLEASE KNOW THAT THIS IS THE
 WRONG CODE CYCLE AND HAS NEVER BEEN ADOPTED BY THE CITY
 OF WEST PALM BEACH. PLEASE KNOW THAT AS OF JULY 1, 2001
 THE FLORIDA BUILDING CODE HAS BEEN ADOPTED BY THE STATE
 OF FLORIDA TO BE THE GOVERNING CODE AND THAT THE
 CORRECT CODE CYCLES THAT SHOULD BE ON ANY FUTURE PLAN
 SHEETS SHOULD BE "FBC-2004 WITH 2007 REVISIONS".
 ****NO WRITTEN COMMENT RESPONSE, BUT WORK IS NOW
 INDICATED AS COMPLIANT WITH NFPA #54 & #58. PLANS SHALL
 BE COMPLIANT WITH FBC-2004 FUEL GAS CODE. PLEASE
 INDICATE ON PLANS.
  
 2. THE SUBMITTED PROPANE TANK HOLD DOWN DETAIL HAS AN
 ENGINEER TITLE BLOCK (CARMO ENGINEERING ASSOCIATES,
 INC.) WITH A COPIED SIGNATURE AND DATE WITH NO
 EMBOSSING IMPRESSION SEAL WHICH IS UNACEPTABLE PER FAC
 61G15-23.001. PLEASE KNOW THAT THE FOLLOWING
 INFORMATION IS ALSO REQUIRED TO BE ON THE TITLE BLOCK.
 SEE FAC 61G15-23.002(2) A TITLE BLOCK ON EACH SHEET
 CONTAINING THE PRINTED NAME, ADDRESS, AND LICENSE
 NUMBER OF THE ENGINEER OR IF APPLICABLE, THE NAME AND
 LICENSE NUMBER OF THE ENGINEER, AND THE NAME, ADDRESS
 AND CERTIFICATE OF AUTHORIZATION NUMBER OF THE
 ENGINEERING BUSINESS WILL SATISFY THIS REQUIREMENT.
 NOTE: PER FS 471.003(2)(H) THE CONTRACTOR CAN DO THE
 DESIGN AS LONG AS HE/SHE TAKES THE RESPONSIBILITY FOR
 THE DESIGN BY PRINTING HIS/HER NAME WITH AN ORIGINAL
 SIGNATURE AND DATE.
 ****NO WRITTEN COMMENT RESPONSE AND NOW THE NEW TANK
 HOLD DOWN DETAIL IS FOR AN ABOVE GROUND TANK. THE
 APPLICATION INDICATES AN UNDERGROUND TANK. PLEASE
 CLARIFY.
  
 3. PLEASE CLEARLY INDICTE THE REQUIRED 1ST STAGE
 REGULATOR ON THE RESUBMITTED GAS ISOMETRIC RISER
 DIAGRAM. PER FBC-2004 FUEL GAS SECTION 401.1 SCOPE.
 ****NO RESPONSE, COMMENT NOT ADDRESSED.
  
 4. PLEASE SUBMIT TWO COPIES OF MANUFACTURE SHEETS FOR
 THE 1ST AND 2ND STAGE REGULATORS COMPLIANT WITH
 STANDARDS NFPA 58 AND THE FBC-2004 FUEL GAS CODE
 SECTION 402.2. MANUFACTURE SHEETS MUST CLEARLY INDICATE
 THE MAKE, MODEL NUMBER, BTU LOAD CAPACITY, AND A
 LISTING FROM A NATIONALLY RECOGNIZED TESTING LABORATORY
 SUCH AS CSA, AGA, OR UL.
 ****NO RESPONSE, COMMENT NOT ADDRESSED.
  
 5. PLEASE POVIDE MANUFACTURE SPECIFICATIONS FOR THE
 GENERATOR CLEARLY INDICATING THE RECOMMENDED SETBACKS
 FROM STRUCTURES.
 ****NO RESPONSE, COMMENT NOT ADDRESSED. -- SUBMIT
 INSTALLATION INSTRUCTIONS SHOWING ALL CLEARANCES FOR
 EACH SIDE OF THE GENERATOR.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]
  

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2008-10-01 Cont ID  
Sent By btrobaug Date 2008-09-30 Time 16:20 Rev Time 0.00
Received By mperson Date 2008-10-01 Time 13:48 Sent To B
Notes
2008-10-01 15:01:41GAS PLAN REVIEW:
 DENIED:
  
 PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH
 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO
 CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE
 (F.A.C.), AND FLORIDA STATUTES (F.S.).
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 GAS PLAN REVIEW TO MEET CODE COMPLIANCE.
  
 1. THE SUBMITTED GAS SITE AND ISOMETRIC RISER DIAGRAM
 ARE INDICATING THE PLAN SHEETS TO BE COMPLIANT WITH THE
 "SOUTH FLORIDA BUILDING CODE 2004". PLEASE KNOW THAT
 THE SOUTH FLORIDA BUILDING CODE WAS FOR THE MIAMI-DADE
 AND BROWARD COUNTIES. ALSO PLEASE KNOW THAT THIS IS THE
 WRONG CODE CYCLE AND HAS NEVER BEEN ADOPTED BY THE CITY
 OF WEST PALM BEACH. PLEASE KNOW THAT AS OF JULY 1, 2001
 THE FLORIDA BUILDING CODE HAS BEEN ADOPTED BY THE STATE
 OF FLORIDA TO BE THE GOVERNING CODE AND THAT THE
 CORRECT CODE CYCLES THAT SHOULD BE ON ANY FUTURE PLAN
 SHEETS SHOULD BE "FBC-2004 WITH 2007 REVISIONS".
  
 2. THE SUBMITTED PROPANE TANK HOLDOWN DETAIL HAS AN
 ENGINEER TITLE BLOCK (CARMO ENGINEERING ASSOCIATES,
 INC.) WITH A COPIED SIGNATURE AND DATE WITH NO
 EMBOSSING IMPRESSION SEAL WHICH IS UNACCEPTABLE PER FAC
 61G15-23.001. PLEASE KNOW THAT THE FOLLOWING
 INFORMATION IS ALSO REQUIRED TO BE ON THE TITLE BLOCK.
 SEE FAC 61G15-23.002 (2) A TITLE BLOCK ON EACH SHEET
 CONTAINING THE PRINTED NAME, ADDRESS, AND LICENSE
 NUMBER OF THE ENGINEER OR IF APPLICABLE, THE NAME AND
 LICENSE NUMBER OF THE ENGINEER, AND THE NAME, ADDRESS
 AND CERTIFICATE OF AUTHORIZATION NUMBER OF THE
 ENGINEERING BUSINESS WILL SATISFY THIS REQUIREMENT.
 NOTE: PER FS 471.003(2)(H) THE CONTRACTOR CAN DO THE
 DESIGN AS LONG AS HE/SHE TAKES THE RESPOSIBILITY FOR
 THE DESIGN BY PRINTING HIS/HER NAME WITH ORIGINAL
 SIGNATURE AND DATE.
  
 3. PLEASE CLEARLY INDICATE THE REQUIRED 1ST STAGE
 REGULATOR ON THE RESUBMITTED GAS ISOMETRIC RISER
 DIAGRAM. PER FBC-2004 FUEL GAS SECTION 401.1 SCOPE.
  
 4. PLEASE SUBMIT TWO COPIES OF MANUFACTURE SHEETS FOR
 THE 1ST AND 2ND STAGE REGULATORS COMPLIANT WITH
 STANDARDS NFPA 58, AND THE FBC-2004 FUEL GAS CODE SEC
 402.2. MANUFACTURE SHEETS MUST CLEARLY INDICATE THE
 MAKE, MODEL NUMBER, BTU LOAD CAPACITY, AND A LISTING
 FROM A NATIONALLY RECOGNIZED TESTING LABORATORY SUCH AS
 CAS, AGA, OR UL.
  
 5. PLEASE PROVIDE MANUFACTURE SPECIFICATIONS FOR THE
 GENERATOR CLEARLY INDICATING THE RECOMMENDED SETBACKS
 FROM STRUCTURES.
  
 ********IMPORTANT INFORMATION********
 WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE
 OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW
 PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 END OF COMMENTS:
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 PHONE= (561) 805-6730
 FAX= (561) 805-6731
 E-MAIL= [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2009-04-20 Cont ID  
Sent By swurafti Date 2009-04-20 Time 16:43 Rev Time 0.00
Received By swurafti Date 2009-04-20 Time 16:43 Sent To Z
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2009-02-25 Cont ID  
Sent By adarroug Date 2009-02-25 Time 11:16 Rev Time 0.00
Received By adarroug Date 2009-02-25 Time 11:16 Sent To Z
Notes
2009-02-25 11:17:09TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2008-12-03 Cont ID  
Sent By adarroug Date 2008-12-03 Time 16:35 Rev Time 0.00
Received By adarroug Date 2008-12-03 Time 16:35 Sent To Z
Notes
2008-12-03 16:36:12TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-09-29 Cont ID  
Sent By adarroug Date 2008-09-29 Time 14:37 Rev Time 0.00
Received By adarroug Date 2008-09-29 Time 14:37 Sent To E
Notes
2008-09-29 14:38:09TO "SFR" "E"

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-10-09 Cont ID  
Sent By shill Date 2008-10-09 Time 09:18 Rev Time 0.00
Received By shill Date 2008-09-23 Time 09:09 Sent To  
Notes
2008-09-23 09:10:13TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2008-10-01 Cont ID  
Sent By tgordon Date 2008-10-01 Time 10:34 Rev Time 0.30
Received By tgordon Date 2008-10-01 Time 10:34 Sent To G
Notes
2008-10-01 10:40:35*** PROVISO ***
 1) PER 2004 FBC, FUEL GAS - POWERED EQUIPMENT
 PERMANENTLY INSTALLED EQUIPMENT POWERED BY INTERNAL
 COMBUSTION ENGINES SHALL BE INSTALLED IN ACCORDANCE
 WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS AND NFPA
 37.
 NFPA 37 INSTALLATION & USE OF STATIONARY COMBUSTION
 ENGINES & GAS TURBINES: 4.1.4 ENGINES (GENERATORS)
 LOCATED OUTDOORS SHALL BE MINIMUM OF 5 FT FROM OPENINGS
 IN WALLS & AT LEAST 5 FT FROM STRUCTURES HAVING
 COMBUSTIBLE WALLS. A MINIMUM CLEARANCE IS NOT REQUIRED
 WHEN (1) THE ADJACENT WALL HAS A MINIMUM FIRE
 RESISTANCE RATING OF 1 HOUR OR (2) THE WEATHERPROOF
 ENCLOSURE IS CONSTRUCTED OF NON-COMBUSTIBLE MATERIALS,
 AND IT HAS BEEN DEMONSTRATED THAT A FIRE WITHIN THE
 ENCLOSURE WILL NOT IGNITE COMBUSTIBLE MATERIALS OUTSIDE
 THE ENCLOSURE. INFORMATIVE: A.8.2.3.1 EXHAUST SYSTEMS
 SHOULD NOT TERMINATE UNDER STRUCTURES OR WHERE THE
 EXHAUST MIGHT BE DRAWN INTO THE VENTILATION INTAKES.
 2004 FMC 804.3.5 #3, WHERE THE TERMINATION IS LOCATED
 BELOW AN ADJACENT ROOF STRUCTURE, THE TERMINATION POINT
 SHALL BE LOCATED AT LEAST 3 FT FROM THE ROOF STRUCTURE.
 PLEASE NOTE, WHILE ZONING ALLOWS MECHANICAL EQUIPMENT
 TO ENCROACH 4 FT INTO THE REQUIRED SETBACK, GENERATORS
 SHALL MAINTAIN THE REQUIRED ABOVE MENTIONED CLEARANCES
 TO THE ADJACENT PROPERTY STRUCTURES, I.E. FENCE,
 BUILDING, WINDOWS, DOORS, OR OPENINGS. FOLLOW
 MANUFACTURER'S RECOMMENDED CLEARANCES AROUND EQUIPMENT
 FOR SERVICING,AND PROVIDE MANUFACTURER'S INSTALLATION
 INSTRUCTIONS AT THE JOBSITE FOR THE FIELD INSPECTOR.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729

Review Stop Z ZONING
Rev No 4 Status P Date 2009-05-01 Cont ID  
Sent By mcruz Date 2009-05-01 Time 14:11 Rev Time 0.00
Received By mcruz Date 2009-05-01 Time 13:34 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status F Date 2009-03-02 Cont ID  
Sent By mcruz Date 2009-03-02 Time 13:47 Rev Time 0.00
Received By mcruz Date 2009-03-02 Time 13:42 Sent To E
Notes
2009-03-02 13:46:42PLANNING AND ZONING DEPT: ***ZONING FAILED - 2ND
 RESUB***
  
 1. PLEASE PROVIDE ALL RESPONSES IN WRITING. **NO
 WRITTEN RESPONSE, COMMENT NOT ADDRESSED.**
  
 REPEAT COMMENT:
 INDICATE SETBACK DIMENSIONS FROM PROPOSED GENERATOR TO
 ALL ADJACENT PROPERTY LINES. PURSUANT THE ZLDR, SECTION
 94-305(B)(4): MECHANICAL EQUIPMENT MAY NOT PROJECT MORE
 THAN 4 FEET INTO A REQUIRED SETBACK.
  
 NOTE: THE SUBMITTAL OF THE REQUESTED INFORMATION MAY
 GENERATE ADDITIONAL COMMENTS.
  
 FOR ADDITIONAL INFORMATION, THE ZONING AND LAND
 DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT
 WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH
 PLANNING DEPARTMENT WEBSITE AT
 WWW.CITYOFWPB.COM/PLAN/INDEX.HTM.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO
 CONTACT ME.
  
 MAGGIE CRUZ, ASSOCIATE PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: (561) 822-1444 OR (561) 805-6720
 E-MAIL: [email protected]
  

Review Stop Z ZONING
Rev No 2 Status F Date 2008-12-10 Cont ID  
Sent By mcruz Date 2008-12-10 Time 15:54 Rev Time 0.00
Received By mcruz Date 2008-12-10 Time 15:50 Sent To E
Notes
2008-12-10 15:54:13PLANNING AND ZONING DEPT: ***ZONING FAILED***
  
 1. PLEASE PROVIDE ALL RESPONSES IN WRITING.
  
 2. INDICATE SETBACK DIMENSIONS FROM PROPOSED GENERATOR
 TO ALL ADJACENT PROPERTY LINES. PURSUANT THE ZLDR,
 SECTION 94-305(B)(4): MECHANICAL EQUIPMENT MAY NOT
 PROJECT MORE THAN 4 FEET INTO A REQUIRED SETBACK.
  
 NOTE: THE SUBMITTAL OF THE REQUESTED INFORMATION MAY
 GENERATE ADDITIONAL COMMENTS.
  
 FOR ADDITIONAL INFORMATION, THE ZONING AND LAND
 DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT
 WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH
 PLANNING DEPARTMENT WEBSITE AT
 WWW.CITYOFWPB.COM/PLAN/INDEX.HTM.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO
 CONTACT ME.
  
 MAGGIE CRUZ, ASSOCIATE PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: (561) 822-1444 OR (561) 805-6720
 E-MAIL: [email protected]
  

Review Stop Z ZONING
Rev No 1 Status P Date 2008-09-26 Cont ID  
Sent By mcruz Date 2008-09-26 Time 17:57 Rev Time 0.00
Received By mcruz Date 2008-09-26 Time 17:57 Sent To I
Notes
***NONE***