Plan Review Details - Permit 08090363
| Plan Review Stops For Permit 08090363 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2009-04-17 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-04-17 |
Time |
16:14 |
Rev Time |
1.33 |
| Received By |
jwitmer |
Date |
2009-04-17 |
Time |
16:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2009-04-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-04-06 |
Time |
16:17 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2009-04-06 |
Time |
16:17 |
Sent To |
|
|
| Notes |
| 2009-04-06 16:19:19 | BUILDING PLAN REVIEW | | | PERMIT: 08090363 | | | ADD: 701 BELVEDERE RD | | | CONT: LCI CONSTRUCTION | | | TEL: (561)307-4935 | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | APRIL 06/09 | | | 3RD REVIEW | | | ACTION: DENIED | | | | | | 1) THE NEW PLANS ARE NOT SIGNED NOR SEALED. PLANS, | | | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS PREPARED BY | | | THE DESIGN PROFESSIONAL AND BEING FILED FOR PUBLIC | | | RECORD SHALL HAVE THE SIGNATURE AND SEAL OF THE DESIGN | | | PROFESSIONAL AFFIXED TO THE DOCUMENT. | | | FL ADMIN CODE 61G15-23.002 ENGINEERS | | | FL ADMIN CODE 61G16.003 ARCHITECTS | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)805-6731 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2009-01-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-01-08 |
Time |
11:55 |
Rev Time |
3.55 |
| Received By |
jwitmer |
Date |
2009-01-08 |
Time |
9.00 |
Sent To |
|
|
| Notes |
| 2009-01-08 11:38:21 | BUILDING PLAN REVIEW | | | PERMIT: 08090363 | | | ADD: 701 BELVEDERE RD | | | CONT: LCI CONSTRUCTION | | | TEL: (561)307-4935 | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | JAN 08/09 | | | 2ND REVIEW | | | ACTION: DENIED | | | | | | 1A) INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE | | | INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | 2-10) COMPLIED | | | | | | 11A) 13-103.1.1 CODE COMPLIANCE PREPARATION. THE PERSON | | | PREPARING THE COMPLIANCE CALCULATION SHALL CERTIFY THAT | | | THE PLANS AND SPECIFICATIONS COVERED BY THE | | | CALCULATION, OR AMENDMENTS THERETO, ARE IN COMPLIANCE | | | WITH CHAPTER 13 OF THE FLORIDA BUILDING CODE. THIS CODE | | | ARTICLE STANDS BECAUSE THE PLANS DO NOT MATCH THE | | | R-VALUES STATED WITHIN THE DATA INPUT REPORT OF THE | | | ENERGY CALCULATIONS. | | | THE INPUT DATA REPORT INDICATE YOU ARE TAKING CREDIT | | | FOR A R-VALUE OF 12.5 . PLEASE REVIEW CHAPTER 13 | | | APPENDIX B 2.5.5 SLABS ON GRADE AND THE F- FACTORS FOR | | | SLABS-ON-GRADE FLOORS SHALL BE TAKEN FROM TABLE B-26. | | | IN REVIEWING THIS TABLE DEPENDING ON THE F-VALUE OF THE | | | INSULATION AND WIDTH OF INSULATION TO BE ADDES AT THE | | | FLOOR LEVEL. PLEASE CORRELATE PLANS AND ENERGY CALCS . | | | | | | 11B) COMPLIED. | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)805-6731 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-09-30 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-09-30 |
Time |
08:37 |
Rev Time |
3.33 |
| Received By |
jwitmer |
Date |
2008-09-30 |
Time |
06:47 |
Sent To |
|
|
| Notes |
| 2008-09-30 11:17:56 | BUILDING PLAN REVIEW | | | PERMIT: 08090363 | | | ADD: 701 BELVEDERE RD | | | CONT: LCI CONSTRUCTION | | | TEL: (561)307-4935 | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1A) INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE | | | INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | 1B) INFORMATIONAL FL S S 713.13 NOTICE OF COMMENCEMENT, | | | TO BE FILED WITH THE CLERK OF THE COURT. NOTE: | | | 713.13(2) IF THE WORK DESCRIBED IN THE NOTICE OF | | | COMMENCEMENT IS NOT ACTUALLY COMMENCED WITHIN 90 DAYS | | | AFTER THE RECORDING THEREOF, SUCH NOTICE IS NULL & | | | VOID. NOTE: 713.13(6) THE POSTING OF THE NOTICE OF | | | COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE THE FIRST | | | INSPECTION. | | | | | | 1C) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) | | | AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC | | | BUILDING WITH THE 2007 SUPPLEMENTS, PLEASE REVISE SHEET | | | A1 TO THE CURRENT 2007 SUPPLEMENTS. | | | | | | 1D) SHETT A-1 UNDER THE HEADING BUILDING DATA WHERE THE | | | CURRENT CODES ARE LISTED, PLANS FAIL TO IDENTIFY THE | | | 2004FBC EXISTING BUILDING WITH 2007 SUPPLEMENTS NOR THE | | | LEVEL OF ALTERATION HAS NOT BEEN DECLARED BY THE DESIGN | | | PROFESSIONAL 2004 FBC EXIST. SECTION 301.5. | | | | | | 2) SHEET A1 INDICATES A SECTION 4 OF A4 PLANS DO NOT | | | PROVIDE WHAT THE HEIGHT DIFFERENCE IS IN THE FRONT CURB | | | AND ACCESSIBLE RAMP AREAS. IT CAN NOT BE DETERMINED IF | | | THERE IS A GREATER THAN 6" DIFFERENCE IN GRADE THAT | | | ENACT 11.4.8.5. HANDRAILS: IF A RAMP HAS A RISE GREATER | | | THAN 6" OR A HORIZONTAL PROJECTION GREATER THAN 72", | | | THEN IT SHALL HAVE HANDRAILS ON BOTH SIDES. | | | | | | 3) SHEET A-1 WALK IN COOLERS & FREEZERS THE TOTAL | | | SQUARE FOOTAGE OF THE WALK-IN UNITS IS APPROX 417 SQ | | | FT. 2603.4.1.3 LIMITS THE THE AGGREGATE FLOOR AREA TO | | | 400 SQ FT. PLEASE MODIFY, 2603.4.1.3. | | | NOTE THAT THE ACTUAL COOLER AND MECHANICAL EQUIPMENT | | | WILL REQUIRE A SEPERATE PERMIT WHERE AS THE REMAINDER | | | OF THE REQUIREMENTS OF 2603.4.1.3 WILL NEED TO BE MET. | | | SEPERATE REVIEWS WITH ASSOCIATED FEES WILL THEN OCCUR. | | | | | | 4) FL BLD CODE 1609.1.4: COMPONENTS & CLADDING, PROVIDE | | | 2 COPIES OF PRODUCT TESTING REPORTS, MISSING REPORTS | | | ARE AS FOLLOWS: | | | 4A) STORM SHUTTERS- THE REPORT SUBMITTED 02-0809.02 | | | EXPIRED 10/10/07 WILL REQUIRE NEW REPORT RULE 9B-72 | | | (31) ( E) | | | 4B) PRE-ENGINEERED A/C STANDS RULE 9B-72(31)(G) | | | | | | 5) WPB ADMIN CODE 106.3* PRODUCT APPROVALS. THOSE | | | PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | | | | 6) PLEASE NOTE: 104.6*/ 1609.1.4/ 1714.5 STANDARDS FOR | | | WIND-BORNE DEBRIS IMPACT PROTECTION QUESTION# 13 | | | RECOGNIZING SUCH CONCERNS AS ABSENTEE OWNERS, OR CASES | | | WHERE LONGER TIME & EFFORT IS NECESSARY TO SECURE | | | SHUTTERS A COMPLETE INSTALLATION INSTALLATION SCHEDULE | | | FOR SECURING IS DONE SUFFICIENTLY IN ADVANCE OF THE | | | HURRICANE. PROVIDE STORM PANEL INFORMATION WITH | | | INSTALLATION SCHEDULE AND KEY PLAN WITH SPECIFIC | | | ANCHORS AND MOUNTING TO BE USED FOR ALL NON-IMPACT | | | GLAZING. | | | | | | FL BLD CODE 2004 SECTION 106.3.3, 1609.1.4, 1714.5.1 & | | | EXIST BUILD CODE 507.3. PROCEDURES: 1(B) A COMPLETE | | | INSTALLATION SCHEDULE SUMMARIZING & IDENTIFYING OPENING | | | SIZES, STORY HEIGHTS, UNIT MARK NUMBERS, UNIT | | | SPANS/WIDTHS, UNIT STORM BAR REINFORCING REQUIREMENTS, | | | WALL PRESSURE ZONES, SLAT TYPES, ETC., SHALL BE | | | SUBMITTED AT TIME OF PERMIT APPLICATION TO FACILITATE | | | PLAN REVIEW AND PERMIT ISSUANCE. | | | A SAMPLE STORM SHUTTER SCHEDULE IS ATTACHED. | | | | | | IN MATTERS CONCERNING PUBLIC SAFETY, HEALTH, AND THE | | | GENERAL WELFARE NOT SPECIFICALLY ADDRESSED IN THE CODE, | | | SECTION 104.6 OF THE FLORIDA BUILDING CODE, BUILDING, | | | CHAPTER 1, ADMINISTRATIVE CODE2004 EDITION AS AMENDED | | | BY THE CITY OF WEST PALM BEACH, PROVIDES THE ABILITY | | | FOR THE BUILDING OFFICIAL TO IMPLEMENT REQUIREMENTS FOR | | | ENSURING STABILITY, STRENGTH, AND THE PROPER OPERATION | | | OF EXISTING BUILDINGS. | | | | | | 7) BOTH SHEETS A1 & A7 INDICATE A T8 FUTURE DEAL DWAWER | | | BUT NO INFORMATION HAS BEEN PROVIDED PRODUCT | | | INFORMATION, THE SECURING INTO THE STRUCTURAL SHELL OF | | | THE BUILDING.1609.6.1.2. COMPONENTS AND CLADDING. | | | | | | 8) SHEET A-1 MISSING THE REQUIRED 18" BETWEEN THE WATER | | | COOLER AND LATCH SIDE OF THE RESTROOM DOOR. 11-4.13.6 | | | MANEUVERING CLEARENCES AT DOORS. MINIMUM MANEUVERING | | | CLEARANCES | | | AT DOORS THAT ARE NOT AUTOMATIC OR POWER-ASSISTED SHALL | | | BE AS SHOWN IN FIG. 25. THE FLOOR OR GROUND AREA WITH | | | IN THE REQUIRED CLEARANCES SHALL BE CLEAR & LEVEL. | | | | | | 9) SHEET A4 DETAIL 2 THE COUNTER HEIGHT IS 36" BUT THE | | | COUNTER HEIGHT SHOULD BE 34" SECTION 11-5.2. | | | | | | 10) THE ENRGY CALCULATIONS INDICATE THE USE OF 3" | | | ICYNENE INSULATION AT THE CONCRETE DOUBLE TEE ROOF | | | SYSTEM PROVIDING A R VALUE OF 12.3. PLEASE REVIEW | | | 2603.5.2 AND REQUIRED THERMAL BARRIER MEETING THE | | | PROVISIONS OF SECTION 2603.4 . | | | | | | 11A) THE ENERGY CALCULATIONS ALSO INDICATE A R-VALUE OF | | | 5.73 FOR A CONCRETE FLOOR WITH CARPET AND RUBBER | | | PADDING. 804.5.1 MINIMUM CRITICAL RADIANT FLUX. | | | INTERIOR FLOOR FINISH IN VERTICAL EXITS, EXIT | | | PASSAGEWAYS AND EXIT ACCESS CORRIDORS SHALL NOT BE LESS | | | THAN CLASS I IN GROUPS I-2 AND I-3 AND NOT LESS THAN | | | CLASS II IN GROUPS A, B, E, H, I- 4, M, R-1, R-2 AND S. | | | IN ALL OTHER AREAS, THE INTERIOR FLOOR FINISH SHALL | | | COMPLY WITH THE DOC FF-1 ?PILL TEST? (CPSC 16 CFR, PART | | | 1630). | | | | | | | | | 11B) 11-4.5.3 CARPET . IF CARPET OR CARPET TILE IS USED | | | ON A GROUND OR FLOOR SURFACE, THEN IT SHALL BE SECURELY | | | ATTACHED; HAVE A FIRM CUSHION, PAD, OR BACKING, OR NO | | | CUSHION OR PAD; AND HAVE A LEVEL LOOP, TEXTURED LOOP, | | | LEVEL CUT PILE, OR LEVEL CUT/UNCUT PILE TEXTURE. THE | | | MAXIMUM PILE THICKNESS SHALL BE ? INCH (13 MM) [SEE | | | FIGURE 8 (F)]. EXPOSED EDGES OF CARPET SHALL BE | | | FASTENED TO FLOOR SURFACES AND HAVE TRIM ALONG THE | | | ENTIRE LENGTH OF THE EXPOSED EDGE. CARPET EDGE TRIM | | | SHALL COMPLY WITH SECTION 11-4.5.2 . PLEASE PROVIDE | | | MANUFACTURERS INFORMATION ON CARPET AND PAD. | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2009-04-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-04-17 |
Time |
11:11 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-04-17 |
Time |
11:11 |
Sent To |
|
|
| Notes |
| 2009-04-17 11:17:17 | ** REDLINED PLANS*** | | | | | | | | | SPOKE TO ELECTRICAL CONTRACRTOR. WILL PROVIDE FUSED SE | | | RATED FUSED SAFETY SWITCH PER NOTES ON PLANS. 240.21 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2009-03-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-03-24 |
Time |
16:20 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-03-24 |
Time |
16:07 |
Sent To |
|
|
| Notes |
| 2009-03-24 16:20:37 | ** PLANS DENIED ** | | | SOME OF THE SAME NOTES FROM THE PREVIOUS REVIEW ARE | | | STILL IN NEED OF ADDRESSING. | | | | | | 1) NOTE: THIS IS A REPEAT REQUEST TO SUBMIT THE | | | MANUFACTURES SPECS/CUT SHEETS FOR THE NEW PROPOSED | | | TRANSFER SWITCH. BASED ON THE RISER THIS EQUIPMENT MUST | | | BE SERVICE ENTRANCE RATED NOT ONLY RATED AS SERVICE | | | EQUIPMENT. THIS EQUIPMENT MUST HAVE OVER CURRENT | | | PROTECTION AND BE MUST ALSO BE RATED FOR THE AVAILABLE | | | FAULT CURRENT. | | | THERE SEEMS TO BE SOME SORT OF MISPRINT WITH THE RATING | | | OF THE EQUIPMENT ALSO. SHOWN AS 1001. | | | 230.70, 230.71, 230.76, 230.79, 110.9, 110.3, 90.7 | | | | | | 2) NOTE: PLEASE SEE THE INPUT DATA REPORT FOR LIGHTING | | | FOR EXTERIOR. WHEN USING LIGHTING PER HEALTH, SAFETY | | | STATUTES, ORDINANCE, OR REGULATION THIS WILL EXEMPT THE | | | LIGHTING AND REMOVE IT FROM THE OVER ALL FIGURE. AS | | | THERE IS NO ORDINANCE, STATUTE OR OTHER REGULATIONS | | | WHICH REQUIRES THIS LIGHTING, THIS USE MAY NOT BE USED. | | | PLEASE ADJUST CALCULATIONS. | | | 13-415.2, 13-415.2.ABC.1.3. | | | LIGHTING IN A RETAIL OCCUPANCY SPECIFIC TO DISPLAY | | | AREAS HAS AN ADDITIONAL ALLOWANCE UNDER THE 2004 FBC | | | HOWEVER IT IS SPECIFIC TO THE SQUARE FOOTAGE OF THE | | | DISPLAY AREA. | | | | | | 3) NOTE: PLEASE SEE NOTES MARKED AS *IMPORTANT* ON THE | | | PREVIOUS REVIEW. PLEASE BE SURE TO REMOVE THE OLD | | | VOIDED SHEETS FROM SETS AND INSERT THE NEW REVISED | | | SHEETS INTO SETS FOR REVIEW AND STAMPING. | | | | | | 4) NOTE: PLEASE SEE THE NEW REVISED SHEETS WHICH WERE | | | SUBMITTED ARE NOT SIGNED, DATED OR SEALED BY THE | | | DESIGNER OF RECORD. FS 481.221 | | | | | | 5) NOTE: PLEASE SEE RISER AS THIS STILL INDICATES AN | | | EQUIPMENT GROUNDING CONDUCTOR FROM THE GUTTER TO THE | | | NEW TRANSFER SWITCH. PER 250.6, 250.24 THERE CAN NOT BE | | | ANY EQUIPMENT GROUNDING CONDUCTORS BEFORE THE FIRST | | | MEANS OF DISCONNECT ON A SERVICE. ONLY AFTER THE FIRST | | | MEANS OF DISCONNECT IS EQUIPMENT GROUNDING CONDUCTORS | | | INSTALLED. | | | | | | | | | | | | | | | ** IMPORTANT ** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED | | | INTO TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2009-01-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-01-05 |
Time |
15:32 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-01-05 |
Time |
15:32 |
Sent To |
|
|
| Notes |
| 2009-01-05 15:33:01 | ** DENIED 2ND REVIEW ** | | | | | | | | | **SEE NEW NOTES BELOW DUE TO REVISED RISER WHICH DID | | | NOT CONTAIN SOME OF THESE ITEMS ON PREVIOUS REVIEWED | | | PLANS. | | | | | | | | | | | | 1) NOTE: PLEASE SUBMIT THE MANUFACTURE SPECS/CUT SHEETS | | | ON THE NEW PROPOSED SERVICE ENTRANCE RATE TRANSFER | | | SWITCH. | | | 110.3,90.7, ETC | | | | | | 2) NOTE: RISER NOW HAS BEEN REVISED TO INDICATE A #4 | | | NEUTRAL AS PART OF THE FEEDERS FROM PANEL *A* TO NEW | | | SUB PANEL *D*. THIS MUST BE A MISPRINT FOR EQUIPMENT | | | GROUNDING CONDUCTOR? | | | 250 | | | FBC 106.1.1, FOR CLARITY AND COORDINATION OF PLANS. | | | | | | 3) NOTE: PLEASE ADJUST RISER WITH NEW CONDUCTORS NOW | | | BEING SHOWN FROM GUTTER TO THE NE W TRANSFER SWITCH. | | | THE NOTES ABOVE REQUEST THE SPECS/CUT SHEETS HOWEVER | | | THE RISER INDICATES THE OLD DISCONNECT *C* BEING FED | | | FROM TWO LOCATIONS. | | | THE RISER ALSO INDICATES AN EQUIPMENT GROUNDING | | | CONDUCTOR FROM THE GUTTER TO THE TRANSFER SWITCH WHICH | | | IS NOT PERMITTED.250.6,250.24. | | | * EQUIPMENT GROUNDING CONDUCTORS* ARE ONLY INSTALLED | | | AFTER THE FIRS MEANS OF DISCONNECT. | | | | | | 4) NOTE: PLEASE SEE THE PREVIOUS NOTES WITH RESPECT TO | | | THE FLA COM ENERGY CALCULATIONS SUBMITTED. PART OF THE | | | COMMENT IS THE FACT ALL THE INFORMATION ON PLANS NEEDS | | | TO COORDINATE WITH THE SUBMITTED INPUT DATA REPORT. | | | THIS IS NOT COMPLIANT. | | | ONE EXAMPLE: THERE ARE MORE FIXTURES ON THE PLANS FOR | | | THE INTERIOR LIGHTING THAN SHOWN ON THE IDR SUBMITTED. | | | PLEASE SEE TYPE D, G ETC. | | | PLEASE SEE ELECTRICAL PLANS WHICH ALSO CONTAIN A LIGHT | | | FIXTURE SYMBOL HOWEVER NO DESIGNATION IS NOTED ALONG | | | WITH NO CIRCUITING. | | | PLEASE SEE 13-415.2,13-415.2.ABC.1.1, .1.2 AND .1.3. | | | PLEASE COORDINATE ALL. | | | THIS IS NOT THE ONLY ITEM. | | | PLEASE SEE THE SUBMITTED SHEET 4 OF 8 WHICH IDENTIFIES | | | THE BUILDING END USES. WHERE DOES THE DESIGN OF 358.30 | | | AND THE REFERENCE OF 390.30 COME FROM. | | | THIS IS NOT LIKE ANY OTHER CALCULATIONS EVER SUBMITTED. | | | THE REFERENCE HAS ALWAYS BEEN 100 AND THE DESIGN IS | | | DOWN FROM THERE. | | | 13-101, 13-400.3.A. | | | PLEASE SEE 13-401- 13-412 FOR OTHERS. | | | | | | | | | | | | | | | | | | | | | | | | | | | ** IMPORTANT ** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED | | | INTO TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2008-10-06 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-10-06 |
Time |
15:20 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-10-06 |
Time |
15:20 |
Sent To |
|
|
| Notes |
| 2008-10-06 15:20:50 | | | | ** DENIED REVIEW ** | | | | | | 1) NOTE: PLEASE SEE FS 526.143 AND PROVIDE BACK UP | | | REQUIRED SYSTEM FOR MOTOR FUELING. IF A SYSTEM ALREADY | | | EXISTS, PLEASE SHOW SYSTEM AND PROVIDE PERMITTING | | | INFORMATION. NO CURRENT RECORDS WERE LOCATED IN OUR | | | SYSTEM THAT THIS WORK HAS BEEN DONE. PLEASE SEE THE | | | STATUTORY REQUIREMENT AS NOTED. | | | | | | 2) NOTE: PLEASE SEE FBC 13-400.3.A, .3.B, ETC AS THE | | | VERSION SUBMITTED FOR ENERGY CALCULATIONS IS NOT | | | ADOPTED BY THE FBC. THIS SHOULD BE VERSION 2.5. PLEASE | | | GO TO ENERGY GAUGE WEBSITE AS THERE IS A PATCH | | | AVAILABLE TO CHANGE TO VERSION 2.5. | | | | | | 3) NOTE: PLEASE SEE 13-101.1. AS THIS IS AN EXISTING | | | BUILDING PLEASE PROVIDE HOW METHOD A IS BEING USED AS | | | THIS WOULD BE A RENOVATION PER SECTION 202. | | | ONLY IF ALL KNOWN COMPONENTS ARE KNOWN WOULD A METHOD A | | | BE USED. | | | IN EITHER CASE THE SUBMITTED CALCULATIONS ARE NOT CODE | | | COMPLIANT. THE INPUT DATA REPORT ATTACHED AS REQUIRED | | | IS NOT COMPLETE. | | | FOR ONE EXAMPLE: PLEASE SEE THE IDR AS THIS SHOWS NO | | | EXTERIOR LIGHTING. THIS SECTION OF THE IDR IS *BLANK*. | | | HOW IS THIS POSSIBLE WHEN THE PLANS CLEARLY INDICATE | | | MANY EXTERIOR FIXTURES? | | | PLEASE SEE FBC 13-415.2.ABC.1.3 FOR LIGHTING | | | PERFORMANCE CALCULATIONS FOR EXTERIOR. | | | PLEASE ALSO SEE FBC 13-415.2.ABC.1.1, .1.2 FOR INTERIOR | | | LIGHTING. | | | | | | FOR EXAMPLE: THE FIXTURE WATTAGES LISTED ON THE IDR ARE | | | NOT ALL THE SAME AS SHOWN ON THE FIXTURE LEGEND. THERE | | | ARE SEVERAL INCONSISTENCIES. | | | | | | | | | 4) NOTE: PLEASE BE SURE THE FOLLOWING CODES ARE STATED | | | ON ELECTRICAL PLANS AT A MINIMUM. | | | 2005 NFPA-70 | | | 2003 NFPA-101 | | | 2004 FBC W/2007 REVISIONS. | | | | | | 5) NOTE: ALL LOW VOLTAGE SECURITY CAMERAS ETC WILL BE | | | UNDER SEPARATE PERMITS WITH PLANS AND FEES. | | | | | | 6) NOTE: PLEASE COORDINATE ELECTRICAL RISER. AS | | | SUBMITTED THERE ARE SEVERAL ITEMS WHICH NEED TO BE | | | ADDRESSED. | | | THE NEW PANEL *D* IS BEING SHOWN WITH A LOAD WHICH FAR | | | EXCEEDS THE RATING OF THE FEEDERS AND BREAKERS SHOWN IN | | | PANEL *A*. IN FACT PANEL *A* SHOWS ONLY A 30AMP BREAKER | | | AND FEEDERS WHEN IN FACT PANEL *D* HAS A LOAD OF 120.5 | | | AMPS. | | | PLEASE ALSO SEE THE FEEDERS AS NOTED ON PANEL *D* ARE | | | SHOWN AS 3/0 WHEN THE RISER SHOWS THESE AS 1/0. IN | | | EITHER CASE BOTH OF THESE WOULD BE CODE COMPLIANCE | | | BASED ON LOAD HOWEVER COORDINATION IS NEEDED WITH OVER | | | CURRENT PROTECTION ETC. | | | PLEASE SEE THE FEEDERS NOTED ON PANEL *A* ARE SHOWN AS | | | 500MCM IN A 3INCH CONDUIT, YET THE RISER SHOWS THE SAME | | | CONDUCTORS IN A 2 INCH CONDUIT. | | | | | | 7) NOTE: PLEASE INCLUDE NOTES FOR CONTRACTOR TO LABEL | | | ALL MAINS FOR SERVICE PER 230.2E | | | | | | 8) NOTE: PLEASE SHOW ALL EQUIPMENT GROUNDING PATHS/ | | | METHODS AFTER THE FIRST MEANS OF DISCONNECT. | | | | | | 9) NOTE: PLEASE SEE 210.8B2 AS ALL 15,20AMP 120V | | | RECEPTACLES SERVING KITCHEN AREAS WHETHER OR NOT | | | FEEDING APPLIANCES OR EQUIPMENT ON THE COUNTER AREAS | | | WILL BE REQUIRED TO BE GFI OR GFI PROTECTED WITH CLASS | | | A PROTECTION. | | | | | | ** PLEASE KNOW AS THERE IS INFORMATION NOT YET | | | SUBMITTED OR INCOMPLETE ON PLANS THERE MAY BE NEW | | | COMMENTS ON THE FOLLOWING REVIEW WHICH CAN NOT POSSIBLY | | | BE MADE AT THIS TIME. | | | | | | | | | | | | **IMPORTANT** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | | TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANOR PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2009-03-06 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2009-03-06 |
Time |
13:36 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2009-03-06 |
Time |
13:16 |
Sent To |
|
|
| Notes |
| 2009-03-06 13:30:00 | *****APPROVED***** | | | | | | | | | PLAN SHEETS A-1, A-3, AND E-1 WERE STAMPED, INITIALED, | | | AND DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2009-01-14 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2009-01-14 |
Time |
14:09 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2009-01-14 |
Time |
14:09 |
Sent To |
|
|
| Notes |
| 2009-01-14 14:10:22 | COMMENTS FROM LAST FIRE REVIEW HAVE BEEN ADDRESSED. | | | PLANS WILL BE STAMPED WHEN RETURNED WITH OTHER REVIEW | | | COMMENT CORRECTIONS. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2008-10-08 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-10-08 |
Time |
15:19 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-10-08 |
Time |
15:19 |
Sent To |
|
|
| Notes |
| 2008-10-08 15:49:19 | ***DENIED*** | | | | | | 1) THE COOKING OF FOODS THAT PRODUCE GREASE LADEN VAPOR | | | IS REQUIRED TO BE PROTECTED BY AN APPROVED | | | HOOD/SUPPRESSION SYSTEM. PLEASE PROVIDE INFORMATION | | | WITH SUBMITTAL AND IN ADDITION, SEPARATE SHOP DRAWINGS | | | AND PERMITS ARE REQUIRED BEFORE INSTALLATION OF | | | EQUIPMENT. | | | | | | 2) PROVIDE LOCATIONS OF REQUIRED 2A-10B,C RATED FIRE | | | EXTINGUISHERS. | | | | | | 3) CONSTRUCTION, ALTERATION AND DEMOLITION SHALL COMPLY | | | WITH NFPA 241. | | | | | | 4) IF RAMP MEETS THE REQUIREMENTS FOR HANDRAILS ON BOTH | | | SIDES, PROVIDE PRESCRIPTIVE STRENGTH REQUIREMENTS FOR | | | HANDRAILS AND GUARDS IF APPLICABLE. | | | | | | 5) PLEASE DELETE ANY REFERENCE TO FIRE SPRINKLER AND | | | FIRE ALARM SYSTEMS IF NOT PART OF THE SCOPE OF THIS | | | WORK. | | | | | | | | | MIKE WENNERGREN, ASST. FIRE MARSHAL | | | FIRE PLAN REVIEW | | | FIRE PREVENTION (561) 804-4756 |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
N |
Date |
2009-01-28 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-01-28 |
Time |
14:07 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-01-28 |
Time |
14:07 |
Sent To |
|
|
| Notes |
| 2009-01-28 14:08:39 | SEPARATE GAS PERMIT TO BE SUBMITTED WITH REQUIRED | | | INFORMATION BY GAS/PLUMBING CONTRACTOR. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2009-01-28 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-09-18 |
Time |
14:05 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-09-18 |
Time |
14:05 |
Sent To |
|
|
| Notes |
| 2009-01-28 14:07:42 | DENIED | | | REFERENCE: | | | FBC-2004 FUEL GAS | | | | | | 1. SHT P-1 INDICATES GAS PIPING NOTES. A SEPARATE GAS | | | PERMIT IS REQUIRED. THE FOLLOWING INFORMATION IS | | | REQUIRED TO BE SUBMITTED: | | | | | | A. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2004 | | | FUEL GAS CODE. | | | | | | B. SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | | NUMBER OF CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE BEING USED. | | | | | | C. TYPE OF GAS, (LP OR NATURAL). | | | | | | D. BTU LOAD OF EACH APPLIANCE AND THE | | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO | | | THE FBC-2004 FUEL GAS CODE SECS. 401.8 | | | THRU 402.6.1 AND TABLES 402.4(1) THRU | | | 402.4(33). | | | | | | E. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES A.3.1(4). | | | | | | F. SUBMIT CALCULATIONS FOR COMBUSTION | | | AIR (IF APPLICABLE) PER FBC-2004 FUEL | | | GAS CODE SECTION 304. | | | | | | G. INDICATE THE DELIVERY PRESSURE (PSI) | | | PER FBC-2004 FUEL GAS CODE SEC. 402.2. | | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. | | | | | | H. SUBMIT A DETAIL SHOWING THE TYPE, | | | LOCATION, SIZE AND TERMINATION OF THE | | | GAS VENTS PER FBC-2004 FUEL GAS CODE | | | SECS. 502 THRU 505. | | | | | | I. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2004 FUEL GAS CODE SEC 402.2. | | | | | | J. CLEARLY SHOW THE LOCATION AND CAP- | | | ACITY OF LP TANK(S), TYPE OF TANK (DOT | | | OR ASME), THE DISTANCE OF THE TANK FROM | | | THE BUILDING AND ADJACENT PROPERTY LINES | | | THE DISTANCE OF THE TANK FROM ALL SOUR- | | | CES OF IGNITION, OTHER CONTAINERS, BUILD | | | INGS, AND THE LOCATION OF ANY BUILDING | | | OPENINGS BELOW THE RELIEF VALVE OF THE | | | TANK PER NFPA 58, TABLE 3-2.2.2. | | | | | | K. CLEARLY INDICATE ON THE PLAN IF THE | | | LP TANK IS ABOVE OR BELOW GROUND, AND | | | SHOW REQUIRED PROTECTION OF THE TANK AND | | | APPURTENANCES PER NFPA 58. IF THE TANK | | | IS BELOW GROUND THE CONTAINER SHALL BE | | | SECURILY ANCHORED PER NFPA 58 SECTION | | | 3-2.2.7(H). | | | | | | L. EMERGENCY HOOD SHUT DOWN SHUT OFF | | | VALVE TO BE BELOW CEILING. MANUAL SHUT | | | OFF VALVE TO BE UPSTREAM. UNION TO BE | | | DOWN STREAM OF MANUAL VALVE. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2009-04-14 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2009-04-14 |
Time |
16:18 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2009-04-14 |
Time |
16:18 |
Sent To |
|
|
| Notes |
| 2009-04-14 16:18:56 | TO "COMM" BD #5 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2009-03-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-03-02 |
Time |
10:20 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-03-02 |
Time |
10:20 |
Sent To |
|
|
| Notes |
| 2009-03-02 10:22:54 | TO "COMM" BD#54 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-12-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-12-19 |
Time |
08:21 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-12-19 |
Time |
08:21 |
Sent To |
|
|
| Notes |
| 2008-12-19 08:30:14 | TO "COMM" BD#42 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-10-08 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-10-08 |
Time |
16:04 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-09-17 |
Time |
12:13 |
Sent To |
|
|
| Notes |
| 2008-09-17 12:16:47 | TO "COMM" BD#13 |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
3 |
Status |
P |
Date |
2009-04-21 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2009-04-21 |
Time |
16:04 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2009-04-21 |
Time |
16:04 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
F |
Date |
2009-03-11 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2009-03-11 |
Time |
12:12 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2009-03-11 |
Time |
11:41 |
Sent To |
Z |
|
| Notes |
| 2009-03-11 12:45:55 | ***LANDSCAPE REVIEW FAILED*** | | | | | | PLEASE RESPONE TO ALL COMMENTS IN WRITING. | | | 1. REPEAT COMMENT: A TREE ALTERATION PERMIT IS | | | REQUIRED. PLEASE SUBMIT TWO COPIES OF THE LANDSCAPE | | | PLAN WITH THE APPLICATION. ALL EXISTING TREES SHALL BE | | | IDENTIFIED AND THE STATUS (REMOVED, RELOCATED, REMAIN | | | IN PLACE) SHALL BE PROVIDED. THERE ARE TWO HEALTHY | | | QUEEN PALMS AT THE NORTHEAST CORNER OF THE BUILDING | | | THAT HAVE NOT BEEN ACCOUNTED FOR IN ADDITION TO THE | | | OTHER TREES THAT WILL BE REMOVED. | | | | | | 2. REPEAT COMMENT: PURSUANT TO SECTION 94-443(E)(1), AT | | | LEAST 30 PERCENT OF THE LINEAR FEET AROUND THE EXTERIOR | | | OF ALL COMMERCIAL STRUCTURES SHALL BE PLANTED WITH | | | TREES, SHRUBS OR HEDGES. THIRTY FEET WAS PROPOSED AND | | | NOT THE REQUIRED 30 PERCENT. BECAUSE THERE IS A LACK OF | | | FOUNDATION PLANTING, STAFF RECOMMENDS THAT THE HANDICAP | | | SPACE BE SHIFTED TO THE SOUTH BY FIVE FEET AND PROVIDE | | | A PLANTING AREA IN THE LOCATION OF THE CURRENTLY | | | PROPOSED HANDICAP MANEUVERING AREA. THE NEW MANEUVERING | | | AREA WOULD BE ADJACENT TO THE PLANTING BED. | | | | | | 3. PURSUANT TO SECTION 94-444 (B), FUEL OIL OR PROPANE | | | TANKS AND OTHER MECHANICAL EQUIPMENT SHALL NOT BE | | | PERMITTED UNLESS APPROPRIATE SCREENING IS PROVIDED. | | | SCREENING SHALL BE CONSTRUCTED OF BRICK, DECORATIVE | | | CONCRETE, OTHER DECORATIVE MASONRY, OR COMPARABLY | | | DURABLE WOOD AND STEEL. WALLS SHALL BE LANDSCAPED WITH | | | SHRUBS AND HEDGES PLANTED AT TWO-FOOT INTERVALS. | | | | | | 4. PURSUANT TO SECTION 94-443(C)(2), TREES SHALL BE | | | PLANTED AT 30-FOOT INTERVALS AND HEDGES SHALL BE | | | PLANTED AT TWO-FOOT INTERVALS FOR EACH REQUIRED | | | LANDSCAPE BUFFER. A HEDGE SHALL BE INSTALLED ALONG THE | | | INTERIOR PERIMETER OF THE LANDSCAPE BUFFER ADJACENT TO | | | THE SOUTH AND EAST SIDES OF THE SITE. | | | | | | 5. NO MORE THAN A 1 INCH LAYER OF MULCH SHALL COVER THE | | | ROOT BALL OF ANY TREE OR SHRUB. THE THREE INCH LAYER OF | | | MULCH IS APPLIED IN THE PLANT BEDS OUTSIDE OF THE | | | ROOTBALLS. PLANTS AND TREES SHALL BE PLANTED SLIGHTLY | | | ABOVE GRADE TO AVOID RAISING THE SOIL LEVEL AROUND | | | THEIR BASE. | | | | | | | | | | | | | | | IF YOU HAVE ANQ QUESTIONS, PLEASE CONTACT ROBERT | | | KUSSNER @ (561) 822-1462. |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
2008-12-30 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2008-12-30 |
Time |
11:25 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2009-03-11 |
Time |
12:12 |
Sent To |
|
|
| Notes |
| 2008-12-30 12:20:43 | ***LANDSCAPE REVIEW FAILED*** | | | | | | 1. BECAUSE TREES WILL BE REMOVED, A TREE ALTERATION | | | PERMIT IS REQUIRED. THE APPLICATION IS AVAILABLE AT THE | | | FRONT DESK OF THE PLANNING AND ZONING DEPARTMENT. | | | PLEASE SUBMIT (2) COPIES OF THE LANDSCAPE PLAN WITH THE | | | APPLICATION. ALL EXISTING TREES SHALL BE IDENTIFIED AND | | | THE STATUS (REMOVED, RELOCATED, REMAIN IN PLACE) SHALL | | | BE PROVIDED. THERE ARE TWO HEALTHY QUEEN PALMS AT THE | | | NORTHEAST CORNER OF THE BUILDING THAT HAVE NOT BEEN | | | ACCOUNTED FOR. | | | | | | 2. THE LIVE OAKS AND QUEEN PALMS LOCATED ALONG THE | | | SOUTH AND EAST PERIMETER OF THE SITE ARE NOT FLORIDA #1 | | | GRADE OR BETTER WHICH IS A REQUIREMENT. THE OAKS HAVE | | | BEEN PREVIOUSLY HATRACKED AND THE PALMS ARE NOT HEALTHY | | | OR OF PROPER SIZE. PERHAPS, THE CITY COULD ALLOW (2) OR | | | (3) OF THEM TO REMAIN BUT THEY WOULD NEED TO BE | | | RELOCATED TO A LESS CONSPICUOUS LOCATION AND GROUPED | | | TOGETHER. | | | | | | 3. NEW TREES WILL BE REQUIRED ALONG THE EAST AND SOUTH | | | PERIMETER OF THE SITE TO REPLACE THE EXISTING TREES | | | THAT WILL NEED TO BE REMOVED. THERE ARE OVERHEAD WIRES | | | ALONG THE SOUTH PERIMETER OF THE SITE. YOU SHALL COMPLY | | | WITH FPL'S "PLANT THE RIGHT TREE IN THE RIGHT PLACE" | | | GUIDELINES THAT RESTRICT THE SPECIES OF TREE THAT CAN | | | BE PLANTED NEAR OR UNDER POWER LINES. IN ADDITION, | | | THERE SHALL BE CONTINUITY WHEN SELECTING THE SPECIES. | | | IF YOU DECIDE TO USE A PALM GROUPING, THEN ALL TREES | | | WITHIN THE GROUPING SHALL BE OF THE SAME SPECIES. THE | | | SAME APPLIES FOR PROPOSED TREES TO BE PLANTED ALONG | | | EITHER THE EAST OR SOUTH SIDES OF THE SITE. | | | | | | 4. PURSUANT TO SECTION 94-443(E)(1), AT LEAST 30 | | | PERCENT OF THE LINEAR FEET AROUND THE EXTERIOR OF ALL | | | COMMERCIAL STRUCTURES SHALL BE PLANTED WITH TREES, | | | SHRUBS OR HEDGES. BECAUSE THERE IS A LACK OF FOUNDATION | | | PLANTING, STAFF RECOMMENDS THAT THE HANDICAP SPACE BE | | | SHIFTED TO THE SOUTH BY (5) FEET AND PROVIDE A PLANTING | | | AREA IN THE LOCATION OF THE CURRENTLY PROPOSED HANDICAP | | | MANEUVERING AREA. THE NEW MANEUVERING AREA WOULD BE | | | ADJACENT TO THE PLANTING BED. PLEASE NOTE THAT THERE IS | | | AN ICE MACHINE THAT WILL NEED TO BE RELOCATED ELSEWHERE | | | TO ALLOW PASSAGE TO THE FRONT DOOR FROM THE WEST. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT | | | KUSSNER @ (561) 822-1462. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2009-04-27 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-04-27 |
Time |
15:33 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-04-27 |
Time |
15:33 |
Sent To |
B |
|
| Notes |
| 2009-04-27 16:20:57 | SENT TO LMARTINEZ FOR PROCESSING |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2009-04-07 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2009-04-07 |
Time |
14:32 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2009-04-07 |
Time |
14:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2009-03-26 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-03-26 |
Time |
10:32 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-03-26 |
Time |
10:32 |
Sent To |
|
|
| Notes |
| 2009-03-26 10:34:31 | ALL PREVIOUS REVIEW COMMENTS HAVE BEEN ADDRESSED. | | | HOWEVER, THE NEW M-1 SHEET WITH CORRECTIONS WAS NOT | | | SIGNED AND SEALED BY THE DESIGNER OF RECORD. PLEASE | | | MAKE SURE ALL SHEETS PREPARED BY THE DESIGNER ARE | | | PROPERLY SIGNED, SEALED AND DATED IN ACCORDANCE WITH | | | FAC RULE 61G-15. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2009-02-01 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-02-01 |
Time |
10:50 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-02-01 |
Time |
10:04 |
Sent To |
PC |
|
| Notes |
| 2009-02-01 10:50:02 | REVIEW #: 2ND | | | ACTION: DENIED | | | | | | FBC 2004 CODE FAMILY W/ 2007 SUPPLEMENTS | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | THE FOLLOWING COMMENTS ARE NUMBERED TO CORRESPOND WITH | | | PREVIOUS REVIEW COMMENTS FOR THE PURPOSE OF CONTINUITY: | | | | | | 1. *PREVIOUS COMMENT* PAGE M-1 FLOOR PLAN SHOWS DUCT | | | SMOKE DETECTORS ON THE RETURN SIDE OF AHU 1 AND AHU 2. | | | DUCT DETECTORS SHALL BE ON THE SUPPLY SIDE OF THE FANS | | | IN ACCORDANCE WITH FBCM 606.2.1. | | | | | | *COMMENT #1 PARTIALLY ADDRESSED*: SOMKE DETECTORS HAVE | | | BEEN RELOACTED TO SUPPLY SIDE OF THE SYSTEM AS REQUIRED | | | BY FBCM 606.2.1. HOWEVER, THE DETECTOR FOR AHU 1 IS | | | SHOWN DOWNSTREAM OF THE FIRST AND LARGEST SUPPLY | | | BRANCH. SMOKE DETECTORS SHALL BE INSTALLED IN A | | | LOCATION WHERE THEY WILL MONITOR THE ENTIRE AIRFLOW | | | CONVEYED BY THE SYSTEM IN ACCORDANCE WITH FBCM 606.3. | | | IN OTHER WORDS, THE DETECTOR MUST BE LOCATED BEFORE OR | | | UPSTREAM OF THE FIRST SUPPLY BRANCH. SHOW THIS DETECTOR | | | ON PLANS IN A LOCATION WHICH IS IN COMPLIANCE WITH THIS | | | FBCM 606.2.1 AND 606.3. PLEASE SHOW COMPLIANCE ON | | | PLANS, DO NOT JUST QUOTE THE CODE SECTION IN ACCORDANCE | | | WITH FBCB 106.1.1. | | | | | | 2. *PREVIOUS COMMENT* OUTSIDE AIR INTAKES FOR AHU-1 AND | | | AHU-2 SHALL BE PROVIDED WITH SHUTOFF DAMPER CONTROLS IN | | | ACCORDANCE WITH FBCB 13-409.1.ABC.3.3. | | | | | | *COMMENT #2 PARTIALLY ADDRESSED*: ARE MOTORIZED OR | | | MANUAL BACKDRAFT DAMPERS TO BE INSTALLED AT THIS | | | LOCATION? IF A MOTORIZED DAMPER IS TO BE USED, | | | PROVISIONS FOR POWER AND CONTROL WILL BE REQUIRED. | | | PLEASE SHOW ON PLANS HOW COMPLIANCE WITH FBCB | | | 13-407.1.ABC.3.3 IS TO BE ACHIEVED RATHER THAN QUOTING | | | THE SECTION PER FBCB 106.1.1. | | | | | | 3. OK | | | | | | 4. OK | | | | | | 5. *PREVIOUS COMMENT* NO INSTALLATION DETAILS PROVIDED | | | IN PLANS. PROVIDE DETAILED INSTALLATION INSTRUCTIONS | | | FOR ALL MECHANICAL EQUIPMENT AND APPLIANCES WHICH ARE | | | TO BE INSTALLED OUTDOORS. ALSO INCLUDE SUPPORTING | | | DOCUMENTATION FOR WIND RESISTANCE. MECHANICAL | | | EQUIPMENT, APPLIANCES AND SUPPORTS THAT ARE EXPOSED TO | | | WIND SHALL BE DESIGNED AND INSTALLED TO RESIST THE WIND | | | PRESSURES ON THE EQUIPMENT AND THE SUPPORTS AS | | | DETERMINED IN ACCORDANCE WITH FBCM 301.13. ALSO | | | REQUIRED IS DATA FROM ALL OUTDOOR APPLIANCE | | | MANUFACTURERS SHOWING THEIR APPLIANCES ARE DESIGNED AND | | | CONSTRUCTED TO RESIST WIND PRESSURES IN ACCORDANCE WITH | | | THIS SECTION. THIS INCLUDES ALL CONDENSING UNITS AND | | | HOOD EXHAUST/MAKE-UP AIR FANS. | | | | | | *COMMENT ADDRESSED*: HOWEVER, WIND RESISTANCE | | | REQUIREMENTS FOR ALL OUTDOOR APPLIANCES AND EQUIPMENT | | | NOT COVERED BY THIS PERMIT MUST BE DEMONSTRATED AT TIME | | | OF SEPARATE PERMIT APPLICATION SUCH AS THE KITCHEN | | | EXHAUST FAN, MAKEUP AIR FAN, REMOTE CONDENSERS FOR | | | WALK-IN COOLERS. | | | | | | 6. OK. SUBMIT SEPARAT PERMIT APPLICATIONS WITH FULL | | | DOCUMENTATION FOR THE KITCHEN HOOD AND VENTILATION | | | EQUIPMENT. ALSO, A SEPARATE PERMIT APPLICATION IS | | | REQUIRED FOR THE KITCHEN HOOD FIRE SUPPRESSION SYSTEM. | | | | | | 7. OK SUBJECT TO FIELD INSPECTOR'S VERIFICATION. | | | | | | 8. OK | | | NOTE: MECHANICAL ONLY REVIEWS FOR MECHANICAL PORTIONS | | | OF THE ENERGY CALCULATIONS. PLEASE SEE OTHER TRADE | | | REVIEWS FOR POSSIBLE ADDITIONAL ENERGY CODE RELATED | | | COMMENTS. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2008-09-29 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-09-29 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-09-29 |
Time |
11:27 |
Sent To |
|
|
| Notes |
| 2008-09-29 14:01:26 | REVIEW #: 1ST | | | ACTION: DENIED | | | | | | FBC 2004 CODE FAMILY W/ 2007 SUPPLEMENTS | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | 1. PAGE M-1 FLOOR PLAN SHOWS DUCT SMOKE DETECTORS ON | | | THE RETURN SIDE OF AHU 1 AND AHU 2. DUCT DETECTORS | | | SHALL BE ON THE SUPPLY SIDE OF THE FANS IN ACCORDANCE | | | WITH FBCM 606.2.1. | | | | | | 2. OUTSIDE AIR INTAKES FOR AHU-1 AND AHU-2 SHALL BE | | | PROVIDED WITH SHUTOFF DAMPER CONTROLS IN ACCORDANCE | | | WITH FBCB 13-409.1.ABC.3.3. | | | | | | 3. PLAN SHOWS SECONDARY DRAIN LINES FROM AHU-1 AND | | | AHU-2 TO TERMINATE AT SOFFIT ON EAST SIDE OF BUILDING. | | | THIS DOES NOT APPEAR TO BE A CONSPICUOUS LOCATION. THE | | | AUXILIARY PAN DRAIN SHALL DISCHARGE TO A CONSPICUOUS | | | POINT OF DISPOSAL TO ALERT OCCUPANTS IN THE EVENT OF A | | | STOPPAGE OF THE PRIMARY DRAIN IN ACCORDANCE WITH FBCM | | | 307.2.3(1). | | | | | | 4. HVAC SPECIFICATION #19 CALLS FOR CONDENSATE DISPOSAL | | | AT ROOF DRAINS WHILE FLOOR PLAN CALLS FOR A DRYWELL. | | | PLEASE COORDINATE FLOOR PLANS WITH SPECIFICATIONS TO | | | ACCURATELY REFLECT THE SCOPE OF WORK IN ACCORDANCE WITH | | | FBCB 106.1.1. CONDENSATE FROM ALL COOLING COILS AND | | | EVAPORATORS SHALL BE CONVEYED FROM THE DRAIN PAN OUTLET | | | TO AN APPROVED PLACE OF DISPOSAL IN ACCORDANCE WITH | | | BFCM 307.2.1. | | | | | | 5. NO INSTALLATION DETAILS PROVIDED IN PLANS. PROVIDE | | | DETAILED INSTALLATION INSTRUCTIONS FOR ALL MECHANICAL | | | EQUIPMENT AND APPLIANCES WHICH ARE TO BE INSTALLED | | | OUTDOORS. ALSO INCLUDE SUPPORTING DOCUMENTATION FOR | | | WIND RESISTANCE. MECHANICAL EQUIPMENT, APPLIANCES AND | | | SUPPORTS THAT ARE EXPOSED TO WIND SHALL BE DESIGNED AND | | | INSTALLED TO RESIST THE WIND PRESSURES ON THE EQUIPMENT | | | AND THE SUPPORTS AS DETERMINED IN ACCORDANCE WITH FBCM | | | 301.13. ALSO REQUIRED IS DATA FROM ALL OUTDOOR | | | APPLIANCE MANUFACTURERS SHOWING THEIR APPLIANCES ARE | | | DESIGNED AND CONSTRUCTED TO RESIST WIND PRESSURES IN | | | ACCORDANCE WITH THIS SECTION. THIS INCLUDES ALL | | | CONDENSING UNITS AND HOOD EXHAUST/MAKE-UP AIR FANS. | | | | | | 6. NO INFORMATION WAS PROVIDED WITH THESE PLANS RELATED | | | TO THE COMMERCIAL KITCHEN HOOD SYSTEM. PROVIDE SEPARATE | | | PLANS AND PERMIT APPLICATIONS FOR EACH OF THE FOLLOWING | | | SYSTEMS. SEPARATE PERMITS ARE REQUIRED FOR THE | | | FOLLOWING: HOODS, HOOD SUPPRESSION SYSTEMS, WALK-IN | | | COOLERS. NO PORTIONS OF HOOD OR WALK-IN COOLER SYSTEMS | | | HAVE BEEN REVIEWED FOR CODE COMPLIANCE AT THIS TIME. | | | | | | 7. AHU-1 AND AHU-2 DO NOT APPEAR, BASED ON THE FLOOR | | | PLANS, TO BE FULLY ACCESSIBLE FOR SERVICE AND | | | REPLACEMENT. CLEARANCES AROUND APPLIANCES TO ELEMENTS | | | OF PERMANENT CONSTRUCTION, INCLUDING OTHER INSTALLED | | | EQUIPMENT AND APPLIANCES, SHALL BE SUFFICIENT TO ALLOW | | | INSPECTIONS, SERVICE, REPAIR OR REPLACEMENT WITHOUT | | | REMOVING SUCH ELEMENTS OF PERMANENT CONSTRUCTION IN | | | ACCORDANCE WITH FBCM 306.1. PLEASE SHOW HOW THESE | | | APPLIANCES ARE TO BE ACCESSED FOR SERVICE AND/OR | | | REPLACEMENT. | | | | | | 8. ENERGY CALCULATIONS: A SYSTEM SIZING SUMMARY HAS | | | BEEN PROVIDED IN LIEU OF COOLING LOAD CALCULATIONS AS | | | ALLOWED UNDER FBCB 13-407.1.ABC.1, EXCEPTION #1. THE | | | SYSTEM SIZING SUMMARY SHALL BE SIGNED AND SEALED BY THE | | | DESIGNER OF RECORD IN ACCORDANCE WITH THIS EXCEPTION. | | | NOTE: MECHANICAL ONLY REVIEWS FOR MECHANICAL PORTIONS | | | OF THE ENERGY CALCULATIONS. PLEASE SEE OTHER TRADE | | | REVIEWS FOR POSSIBLE ADDITIONAL ENERGY CODE RELATED | | | COMMENTS. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2009-01-28 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-01-28 |
Time |
14:19 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-01-28 |
Time |
14:19 |
Sent To |
|
|
| Notes |
| 2009-01-28 14:20:50 | SEPARATE GAS PERMIT REQUIRED -- PLANS AND INFORMATION | | | INDICATED ON SHT P-1 TO BE SUBMITTED WITH GAS | | | APPLICATION. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2008-09-19 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-09-19 |
Time |
08:11 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-09-18 |
Time |
16:01 |
Sent To |
|
|
| Notes |
| 2008-09-19 13:53:26 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 FUEL GAS | | | CITY WPB MUNICIPAL CODE | | | | | | 1. SHT A0-1 SHOWS A NEW GREASE INTERCEPTOR. THE GREASE | | | INTERCEPTOR SHALL BE SIZED BY THE UTILITY DEPT, | | | INDUSTRIAL PRETREATMENT DIVISION. PLEASE CONTACT MR. | | | WILLIAM ROBERTS ENVIRONMENTAL COMPLIANCE AT (561) | | | 822-2272, FAX (561) 659-7458 OR E-MAIL | | | [email protected]. ARTICLE III SECTION 90-124. | | | | | | 2. SHT A0-1A DEMOLITION PLAN. PER SECTION 704.5 IN THE | | | REMOVAL OF ANY PART OF A DRAINAGE SYSTEM, DEAD ENDS ARE | | | PROHIBITED. ALL DEMO'D - CAPPED PIPING SHALL REMAIN | | | UNCOVERED UNTIL INSPECTED BY THE FIELD INSPECTOR. | | | | | | 3. SHT A-1 CODE STANDARDS SHALL INCLUDE THE 2007 | | | REVISIONS. | | | | | | 4. SHT P-1 THE 3 COMPARTMENT SINK DETAIL SHOWS THE AIR | | | GAP AS 3". PER SECTION 802.2.1 THE MINIMUM AIR GAP IS | | | TWICE THE EFFECTIVE OPENING OF THE INDIRECT PIPING. THE | | | INDIRECT PIPING IS INDICATED AS 2". THE MINIMUM AIR GAP | | | REQUIRED IS 4". | | | | | | 5. SHT P-2 SANITARY RISER DIAGRAM, THE FLOOR DRAIN IN | | | THE TOILET ROOM IS NOT VENTED AS INDICATED. SECTION | | | 901.2.1. THE FLOOR DRAIN SHOULD BE CONNECTED TO THE LAV | | | RISER. -- SHOW THE PIPE SIZES FOR THE TOILET FIXTURES, | | | (W/C & FLOOR DRAIN). TABLES 709.1 & 710.1(1)(2). | | | | | | 6. SHT P-2 SANITARY RISER DIAGRAM, THE PIPING TO THE | | | URINAL IS AN "S" TRAP WHICH IS NOT APPROVED. SECTION | | | 1002.3. PLEASE SHOW THE DRAIN LINE FROM THE URINAL | | | CONNECTING STRAIGHT INTO THE STACK WITHOUT THE VERTICAL | | | DROP AS INDICATED ON THE RISER. (SEE RED LINE | | | CORRECTION ON ONE SET OF PLANS). | | | | | | 7. SHT P-2 SANITARY RISER DIAGRAM, CLEANOUTS ARE | | | REQUIRED NEAR THE JUNCTION OF THE BUILDING DRAIN AND | | | THE BUILDING SEWER PER SECTION 708.3.5. -- ALSO TWO WAY | | | CLEANOUTS ARE REQUIRED AT THE AFFLUENT PIPING & THE | | | EFFLUENT PIPING OF THE GREASE INTERCEPTOR PER UTILITY | | | STANDARD FOR GREASE INTERCEPTORS. | | | | | | 8. SHT P-2 WATER ISOMETRIC RISER DIAGRAM. A WATER | | | HAMMER ARRESTOR IS REQUIRED ON THE SUPPLY PIPE FOR THE | | | ICE MAKER INSTALLED NEAR THE FIXTURE IN AN EFFECTIVE | | | RANGE PER PDI-HW 201. PLEASE SHOW ON RISER DIAGRAM. | | | SECTION 604.9. | | | | | | 9. SHT P-1 INDICATES GAS PIPING NOTES. A SEPARATE GAS | | | PERMIT IS REQUIRED. THE FOLLOWING INFORMATION IS | | | REQUIRED TO BE SUBMITTED: | | | | | | A. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2004 | | | FUEL GAS CODE. | | | | | | B. SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | | NUMBER OF CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE BEING USED. | | | | | | C. TYPE OF GAS, (LP OR NATURAL). | | | | | | D. BTU LOAD OF EACH APPLIANCE AND THE | | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO | | | THE FBC-2004 FUEL GAS CODE SECS. 401.8 | | | THRU 402.6.1 AND TABLES 402.4(1) THRU | | | 402.4(33). | | | | | | E. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES A.3.1(4). | | | | | | F. SUBMIT CALCULATIONS FOR COMBUSTION | | | AIR (IF APPLICABLE) PER FBC-2004 FUEL | | | GAS CODE SECTION 304. | | | | | | G. INDICATE THE DELIVERY PRESSURE (PSI) | | | PER FBC-2004 FUEL GAS CODE SEC. 402.2. | | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. | | | | | | H. SUBMIT A DETAIL SHOWING THE TYPE, | | | LOCATION, SIZE AND TERMINATION OF THE | | | GAS VENTS PER FBC-2004 FUEL GAS CODE | | | SECS. 502 THRU 505. | | | | | | I. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2004 FUEL GAS CODE SEC 402.2. | | | | | | J. CLEARLY SHOW THE LOCATION AND CAP- | | | ACITY OF LP TANK(S), TYPE OF TANK (DOT | | | OR ASME), THE DISTANCE OF THE TANK FROM | | | THE BUILDING AND ADJACENT PROPERTY LINES | | | THE DISTANCE OF THE TANK FROM ALL SOUR- | | | CES OF IGNITION, OTHER CONTAINERS, BUILD | | | INGS, AND THE LOCATION OF ANY BUILDING | | | OPENINGS BELOW THE RELIEF VALVE OF THE | | | TANK PER NFPA 58, TABLE 3-2.2.2. | | | | | | K. CLEARLY INDICATE ON THE PLAN IF THE | | | LP TANK IS ABOVE OR BELOW GROUND, AND | | | SHOW REQUIRED PROTECTION OF THE TANK AND | | | APPURTENANCES PER NFPA 58. IF THE TANK | | | IS BELOW GROUND THE CONTAINER SHALL BE | | | SECURILY ANCHORED PER NFPA 58 SECTION | | | 3-2.2.7(H). | | | | | | L. EMERGENCY HOOD SHUT DOWN SHUT OFF | | | VALVE TO BE BELOW CEILING. MANUAL SHUT | | | OFF VALVE TO BE UPSTREAM. UNION TO BE | | | DOWN STREAM OF MANUAL VALVE. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
5 |
Status |
P |
Date |
2009-04-28 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2009-04-28 |
Time |
09:29 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2009-04-28 |
Time |
09:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
F |
Date |
2009-04-21 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2009-04-21 |
Time |
09:36 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2009-04-21 |
Time |
09:36 |
Sent To |
|
|
| Notes |
| 2009-04-21 09:50:28 | ZONING PLAN REVIEW | | | | | | PERMIT NO.: 08090363 | | | ADDRESS: 701 BELVEDERE | | | CONTRACTOR/CONTACT: DAVID | | | TELEPHONE NO.: 662.3377 | | | SCOPE OF REVIEW: RESUBMITTAL OF RENOVATED GAS | | | STATION/CONVENIENCE STORE. REVISIONS TO SHEETS LP-1, | | | LP-2, TP-1, AO-1, M1, EO.1, E1, AND E2. | | | | | | REVIEW STATUS: FAILED | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | THE FOLLOWING IS/ARE REPEAT COMMENT(S): | | | | | | 1) PURSUANT TO THE FINAL ORDER FOR ZBA CASE NO. 3212, | | | THE CITY OF WEST PALM BEACH POLICE DEPARTMENT - CRIME | | | PREVENTION UNIT, SHALL REVIEW AND APPROVE THE | | | CONSTRUCTION DRAWINGS TO ENSURE THE ADHERENCE TO | | | GENERALLY-ACCEPTED CRIME PREVENTION THROUGH | | | ENVIRONMENTAL DESIGN (CPTED) PRINCIPLES. PLEASE PROVIDE | | | WRITTEN CONFIRMATION FROM KELLY CARSILLO, CRIME | | | PREVENTION OFFICE, THAT SUCH APPROVAL HAS BEE ISSUED. | | | MS. CARSILLO MAY BE REACHED AT (561) 822-1620. YOUR | | | RESPONSES INDICATE THAT A LETTER WAS PROVIDED, HOWEVER, | | | NO LETTER WAS INCLUDED IN THE RESUBMITTAL PACKAGE. | | | | | | 2) THE ORIGINAL LANDSCAPE PLAN IDENTIFIED BOUGAINVILLEA | | | ON THE EXTERIOR OF THE FENCE SURROUNDING THE MECHANICAL | | | EQUIPMENT. THIS WAS REQUIRED AS AN ALTERNATE TO PUTTING | | | IN A SOLID OPAQUE FENCE. THE REVISED PLANS HAVE REMOVED | | | THIS PLANTING MATERIAL. THE LANSCAPE PLANS SHALL BE | | | REVISED TO SHOW THE INSTALLATION OF THE LANDSCAPE | | | SCREENING, OR A SOLID OPAQUE FENCE SHALL BE PROVIDED. | | | THE LANDSCAPE PLAN DOES SHOW BOUGAINVILLEA ALONG A | | | MAJORITY OF THE CHAINLINK FENCE, BUT NOT IN FRONT OF | | | THAT PORTION OF THE FENCE THAT SURROUNDS THE MECHANCIAL | | | EQUIPMENT. | | | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER, | | | AT (561) 822-1435. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2009-03-10 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2009-03-10 |
Time |
20:07 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2009-03-10 |
Time |
20:07 |
Sent To |
|
|
| Notes |
| 2009-03-10 20:11:09 | ZONING PLAN REVIEW | | | | | | PERMIT NO.: 08090363 | | | ADDRESS: 701 BELVEDERE | | | CONTRACTOR/CONTACT: DAVID | | | TELEPHONE NO.: 662.3377 | | | SCOPE OF REVIEW: RESUBMITTAL OF RENOVATED GAS | | | STATION/CONVENIENCE STORE. REVISIONS TO SHEETS AO-1, | | | M-1, EO.1, E-1, E-2, LP-1, LP-2, AND TP-1 | | | | | | REVIEW STATUS: FAILED | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | THE FOLLOWING IS/ARE REPEAT COMMENT(S): | | | | | | 1) PURSUANT TO THE FINAL ORDER FOR ZBA CASE NO. 3212, | | | THE CITY OF WEST PALM BEACH POLICE DEPARTMENT - CRIME | | | PREVENTION UNIT, SHALL REVIEW AND APPROVE THE | | | CONSTRUCTION DRAWINGS TO ENSURE THE ADHERENCE TO | | | GENERALLY-ACCEPTED CRIME PREVENTION THROUGH | | | ENVIRONMENTAL DESIGN (CPTED) PRINCIPLES. PLEASE PROVIDE | | | WRITTEN CONFIRMATION FROM KELLY CARSILLO, CRIME | | | PREVENTION OFFICE, THAT SUCH APPROVAL HAS BEE ISSUED. | | | MS. CARSILLO MAY BE REACHED AT (561) 822-1620. YOUR | | | RESPONSES INDICATE THAT A LETTER WAS PROVIDED, HOWEVER, | | | NO LETTER WAS INCLUDED IN THE RESUBMITTAL PACKAGE. | | | | | | THE FOLLOWING IS/ARE NEW COMMENT(S) BASED UPON | | | MODIFICATIONS THAT WERE MADE ON THE REVISED SHEET(S): | | | | | | 1) THE ORIGINAL LANDSCAPE PLAN IDENTIFIED BOUGAINVILLEA | | | ON THE EXTERIOR OF THE FENCE SURROUNDING THE MECHANICAL | | | EQUIPMENT. THIS WAS REQUIRED AS AN ALTERNATE TO PUTTING | | | IN A SOLID OPAQUE FENCE. THE REVISED PLANS HAVE REMOVED | | | THIS PLANTING MATERIAL. THE LANSCAPE PLANS SHALL BE | | | REVISED TO SHOW THE INSTALLATION OF THE LANDSCAPE | | | SCREENING, OR A SOLID OPAQUE FENCE SHALL BE PROVIDED. | | | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER, | | | AT (561) 822-1435. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2008-12-24 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2008-12-24 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2008-12-24 |
Time |
11:16 |
Sent To |
|
|
| Notes |
| 2008-12-24 11:41:08 | ZONING PLAN REVIEW | | | | | | PERMIT NO.: 08090363 | | | ADDRESS: 701 BELVEDERE ROAD | | | CONTRACTOR/CONTACT: DAVE - GRUBER HALL CORP. | | | TELEPHONE NO.: (561) 662-3377 | | | | | | REVIEW STATUS: FAILED | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1) PURSUANT TO THE FINAL ORDER FOR ZBA CASE NO. 3212, | | | THE CITY OF WEST PALM BEACH POLICE DEPARTMENT - CRIME | | | PREVENTION UNIT, SHALL REVIEW AND APPROVE THE | | | CONSTRUCTION DRAWINGS TO ENSURE THE ADHERENCE TO | | | GENERALLY-ACCEPTED CRIME PREVENTION THROUGH | | | ENVIRONMENTAL DESIGN (CPTED) PRINCIPLES. PLEASE PROVIDE | | | WRITTEN CONFIRMATION FROM KELLY CARSILLO, CRIME | | | PREVENTION OFFICE, THAT SUCH APPROVAL HAS BEE ISSUED. | | | MS. CARSILLO MAY BE REACHED AT (561) 822-1620. | | | | | | 2) PURSUANT TO THE FINAL ORDER FOR ZBA CASE NO. 3212, | | | LIGHTING SHALL NOT EXCEED 0.5 FOOT CANDLES WHEN | | | MEASURED FROM THE ADJACENT RESIDENTIAL ZONING DISTRICT. | | | SHEET E0.1 SHOWS LEVELS EXTENDING UP TO 2.4 | | | FOOTCANDLES. THE PLANS PROVIDE A NOTE REGARDING | | | MITIGATION BY THE EXISTING FENCE, HOWEVER, WILL THIS | | | FENCE RESULT IN LEVELS OF 0.5 FOOTCANDLES OR LESS? | | | PLEASE CLARIFY. | | | | | | 3) THE SITE PLAN AND THE LANDSCAPE PLAN DO NOT | | | CORRESPOND REGARDING THE SIZE OF THE SCREENED | | | MECHANICAL AREA AT THE NORTHWEST CORNER OF THE | | | BUILDING. THE SITE PLAN SHOWS A MUCH LARGER ENCLOSURE | | | AND APPEARS TO CONFLICT WITH SOME OF THE PROPOSED | | | LANDSCAPING. PLEASE ENSURE THAT ALL PLANS MATCH | | | ACCORDINGLY. ADDITIONALLY, THE SITE DATA TABLE MAY NEED | | | TO BE ADJUSTED AS A PORTION OF THIS AREA IS NO LONGER | | | PROPOSED TO BE LANDSCAPING. | | | | | | THE FOLLOWING ITEMS DO NOT NEED TO BE CORRECTED, BUT | | | ARE SIMPLY NOTES REGARDING THE PROJECT: | | | | | | A) THE OWNER WILL BE RESPONSIBLE FOR ROLLING THE | | | DUMPSTER TO A SUITABLE LOCATION FOR PICK-UP BY THE | | | SANITATION TRUCK AND RETURNED TO THE ENCLOSURE UPON | | | PICK-UP. | | | | | | B) ALL SIGNAGE SHALL BE SUBMITTED UNDER SEPARATE | | | PERMIT. | | | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER, | | | AT (561) 822-1435. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2008-09-26 |
|
|
Cont ID |
|
| Sent By |
bpowell |
Date |
2008-09-26 |
Time |
16:49 |
Rev Time |
0.00 |
| Received By |
bpowell |
Date |
2008-09-26 |
Time |
16:49 |
Sent To |
|
|
| Notes |
| 2008-09-26 16:48:46 | 1. THE PARKING DETAIL SHALL BE CORRECTED TO SHOW THAT | | | THE PARKING SPACES ARE DOUBLE STRIPED, PER SECTION | | | 94-485(G) REQUIRED OFF-STREET PARKING SPACES SHALL BE | | | DELINEATED BY FOUR INCH WHITE DOUBLE STRIPED LINES. | | | PLEASE SEE THE ATTACHED DETAIL. | | | 2. THE LOCATION OF THE GREASE TRAP WILL CONFLICT WITH | | | THE PLACEMENT OF THE DAHOON HOLLY TREES. | | | | | | IF YOU HAVE ANY QUESTIONS OR COMMENTS PLEASE CONTACT; | | | BOBBY POWELL JR., PLANNER, [email protected], (561) | | | 822-1401. |
|
|
|