| Plan Review Stops For Permit 08090347 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2008-12-08 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-12-08 |
Time |
16:23 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-12-08 |
Time |
16:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2008-11-12 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-11-12 |
Time |
11:24 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-11-12 |
Time |
11:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-10-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-10-03 |
Time |
09:10 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-10-03 |
Time |
09:10 |
Sent To |
|
|
| Notes |
| 2008-10-03 09:16:43 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2004 | | | FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FS FLORIDA STATUTE | | | | | | 1. PLEASE REVISE THE PLAN TO SHOW THE BUILDING AND THE | | | ACCESSIBLE BUILDING ENTRANCES, FBC11-4.6.2. | | | | | | 2. PROVIDE THE FOLLOWING INFORMATION ON THE PLAN; TOTAL | | | NUMBER OF PARKING SPACES, TOTAL NUMBER OF ACCESSIBLE | | | SPACES FBC11-4.2(5)(A), FBC11-4.1.6(1)(B). | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
P |
Date |
2008-12-08 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2008-12-08 |
Time |
|
Rev Time |
1.00 |
| Received By |
mgonzale |
Date |
2008-12-08 |
Time |
|
Sent To |
ENG |
|
| Notes |
| 2008-12-08 16:12:18 | ENGINEERING REVIEW: PASSED WITH PROVISO 11-08-08 | | | | | | PREVIOUS COMMENTS STILL APPLY! | | | | | | NEW COMMENT IS ADA RELATED. THE STAIR RAIL MUST COMPLY | | | WITH LATEST ADA. | | | PROPER EXTENSION COVERAGE MUST BE PROVIDED. | | | | | | PROJECT COORDINATOR | | | MANNY GONZALEZ | | | ENGINEERING SERVICES | | | (561) 494-1085 | | | | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2008-11-17 |
|
|
Cont ID |
|
| Sent By |
Manny G |
Date |
2008-11-17 |
Time |
|
Rev Time |
1.00 |
| Received By |
mgonzale |
Date |
2008-12-08 |
Time |
15:22 |
Sent To |
ENG |
|
| Notes |
| 2008-11-17 15:23:57 | APPROVED AS NOTED- | | | | | | COMPLY WITH THE FOLLOWING: | | | CODE OF ORDINANCES, CITY OF WEST PALM BEACH, FLORIDA, | | | CODIFIED THROUGH ORD. NO. 4183-08, ADOPTED SEPT. 22, | | | 2008. (SUPPLEMENT NO. 18), CHAPTER 90 UTILITIES, | | | ARTICLE V. STORMWATER POLLUTION PREVENTION | | | SEC. 90-203. PROHIBITED DISCHARGES; ILLICIT | | | CONNECTIONS. | | | (A) GENERAL PROHIBITION. EXCEPT AS PROVIDED IN SECTION | | | 90-205, AND EXCEPT PURSUANT TO A VALID NPDES | | | PERMIT, IT SHALL BE UNLAWFUL FOR ANY PERSON TO | | | DIRECTLY OR INDIRECTLY DEPOSIT, DISCHARGE, SPILL, OR | | | DUMP INTO | | | ANY OF THE PUBLIC WATERS OR MUNICIPAL SEPARATE STORM | | | SEWER SYSTEM WITHIN THE CITY, ANY SUBSTANCE OTHER | | | THAN THAT COMPOSED ENTIRELY OF STORMWATER. | | | | | | ANY WORK ENCORACHING IN ROW MUST COMPLY WITH THE | | | FOLLOWING: | | | -DRIVEWAY APPROACH AND OR SIDEWALK PLAN NEEDS TO BE | | | APPROVED BY THE ROW PERMIT REVIEWER AT THE TRAFFIC | | | ENGINEERING OFFICE PRIOR TO BEING SUBMITTED TO | | | CONSTRUCTION SERVICES. | | | - NO SIDEWALK OR DRIVEWAY APPROACH PLAN SUBMITTED OR | | | SUBMITTED WITH OUT ENGINEERING SERVICES DEPARTMENT | | | APPROVED STAMP. PRIOR TO SUBMITTING ROW PERMIT ASK THE | | | RECEPTIONIST TO FAX IT TO YOU OR STOP BY AND PICK UP A | | | COPY. | | | CONTACT THE RIGHT-OF-WAY REVIEWER, WINDEL PALMER, | | | PROJECT COORDINATOR, THE TRAFFIC ENGINEERS OFFICE AT: | | | 1000 ? 45TH STREET, SUITE 15 | | | WEST PALM BEACH, FL 33407 TELEPHONE: (561)494-1041 FAX: | | | (561) 494-1069 | | | | | | MANUEL J GONZALEZ, PROJECT COORDINATOR | | | LOCATION ADDRESS: | | | CITY OF WEST PALM BEACH | | | ENGINEERING SERVICES DEPARTMENT | | | 1000 - 45TH STREET, SUITE 15 | | | WEST PALM BEACH FL 33407 | | | MAILING ADDRESS: | | | CITY OF WEST PALM BEACH | | | ENGINEERING SERVICES DEPARTMENT | | | P.O. BOX 3506 | | | WEST PALM BEACH FL 33401 | | | TELEPHONE: | | | 45TH STREET OFFICE : 561-494-1040 | | | 45TH DIRECT: 561-494-1085 | | | FAX: 561-494-1117 | | | CITY HALL OFFICE: (561) 805-6723 | | | CITY HALL DIRECT: (561) 805-6327 | | | CITY HALL FAX: (561) 805-6731 OR 805-6676 | | | NEXTEL: 561-644-7301 | | | NEXTEL DIRECT CONNECT: 159*28165*38 | | | EMERGENCIES: | | | CENTRAL OPERATIONS CENTER (DISPATCH) 561-822-2210 | | | E-MAIL: | | | [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2008-09-24 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2008-09-24 |
Time |
11:30 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2008-09-24 |
Time |
11:25 |
Sent To |
B |
|
| Notes |
| 2008-09-24 11:30:13 | FAILED FOR FOLLOWING REASONS: | | | | | | 1. PLEASE SHOW ON DRAWINGS THE POLLUTION PREVENTION | | | DETAILS,CLOTHES USED FOR SILT FENCE, TURBIDITY BARRIER | | | ETC., PLANS SHOWING SILT FENCE AROUND THE SITE & | | | TURBIDITY BARRIER AROUND STORM CATCH BASIN DRAINS | | | DURING CONSTRUCTION AND ALL DEMOLITION PHASE. HEIGHT OF | | | FENCE SHOULD BE HIGH ENOUGH PER FDEP TO STOP DUST | | | PARTICLES. | | | | | | 2. PLEASE SHOW ON DRAWING ALL CITY STANDARDS NOTES FOR | | | SIDEWALK, DRIVEWAY, APPROACH, PARKINGS, HANDICAP | | | PARKINGS, DUMPSTER ENCLOSURE, YOU CAN GET A C D FOR ALL | | | CITY STANDARDS NOTES FROM 1000, 45 STREET, ENGINEERING | | | SERVICES, PHONE# 494-1040 | | | | | | 3. PLEASE SHOW ON DRAWINGS DUMPSTER & ITS ENCLOSURE | | | DETAILS PER CITY OF WPB, & LOCATION ON DWG, LOCATION | | | MUST BE ACCESSIBLE FOR PICKUP TRUCK. | | | | | | | | | PLEASE RESPOND EACH ITEM IN DETAIL TO EXPEDITE YOUR | | | PERMITTING PROCESS | | | | | | RASIK CHOKSHI 805-6723 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2008-11-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-11-20 |
Time |
16:53 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-11-20 |
Time |
16:53 |
Sent To |
Z |
|
| Notes |
| 2008-11-20 16:53:59 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-10-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-10-28 |
Time |
15:15 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-10-28 |
Time |
15:15 |
Sent To |
Z |
|
| Notes |
| 2008-10-28 15:16:09 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-09-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-09-19 |
Time |
13:36 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-09-19 |
Time |
13:36 |
Sent To |
ENG |
|
| Notes |
| 2008-09-19 13:36:20 | TO "ENG" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-10-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-10-03 |
Time |
09:16 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-09-16 |
Time |
12:12 |
Sent To |
|
|
| Notes |
| 2008-09-16 12:12:43 | TO "Z" BOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2008-12-08 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2008-12-08 |
Time |
12:58 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2008-12-08 |
Time |
12:51 |
Sent To |
ENG |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2008-10-31 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2008-10-31 |
Time |
13:26 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2008-10-31 |
Time |
12:52 |
Sent To |
ENG |
|
| Notes |
| 2008-10-31 12:59:46 | ***ZONING FAILED*** | | | | | | 1. PLEASE PROVIDE ALL RESPONSES IN WRITING. | | | | | | 2. THERE ARE SOME INCONSISTENCIES WITH THE NUMBER OF | | | PARKING SPACES BETWEEN THE SITE PLANS AND THE DRAWINGS | | | SUBMITTED. PLEASE CLARIFY. | | | | | | 3. THE SITE PLAN SHOWS A LOADING SPACE ON THE SOUTH | | | SIDE OF THE PROPERTY, HOWEVER, IT IS NOT SHOWN ON THE | | | PROPOSED DRAWING/SCOPE OF WORK. PURSUANT TO THE CITY OF | | | WEST PALM BEACH ZONING AND LAND DEVELOPMENT REGULATIONS | | | (ZLDR), SECTION 94-485 - TABLE XV-4: COMMERCIAL USES | | | WITH A GROSS FLOOR AREA OF MORE THAN 1,001 SQUARE FEET | | | REQUIRES AT LEAST ONE (1) LOADING SPACE. | | | | | | 4. PURSUANT TO THE ZLDR, SECTION 94-485(Q)(1): BICYCLE | | | PARKING. NUMBER OF SPACES REQUIRED. ONE (1) BICYCLE | | | PARKING SPACE SHALL BE PROVIDED FOR EVERY 20 AUTOMOBILE | | | PARKING SPACES, OR FRACTION THEREOF, IS REQUIRED FOR | | | THE USE. | | | | | | 5. PURSUANT TO THE ZLDR, SECTION 94-485(N): OFF-STREET | | | PARKING DIMENSIONS. ALL PARKING SPACES REQUIRED BY THIS | | | ARTICLE SHALL BE AT LEAST EIGHT FEET SIX INCHES IN | | | WIDTH AND 18 FEET IN LENGTH; SMALL CAR SPACES SHALL BE | | | AT LEAST EIGHT FEET IN WIDTH AND 16 FEET IN LENGTH. | | | MINIMUM PARKING SPACE AND AISLE DIMENSIONS ARE SET | | | FORTH IN FIGURE XV-2 AND PURSUANT TO - TABLE XV-2; | | | GENERAL PARKING DIMENSIONS: TWO-WAY DIRECTION MOVEMENT | | | REQUIRES A MINIMUM OF 24 FEET WIDE REGARDLESS OF | | | PARKING ANGLE AND DIMENSIONS GIVEN IN THE TABLE. THE | | | SITE PLAN SHOWS COMPLIANCE WITH THIS PROVISION; HOWEVER | | | THE PROPOSED DRAWING/SCOPE OF WORK INDICATES 23 FEET | | | BETWEEN PARKING SPACES. PLEASE CORRECT. | | | | | | FOR ADDITIONAL INFORMATION, THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT | | | WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH | | | PLANNING DEPARTMENT WEBSITE AT | | | WWW.CITYOFWPB.COM/PLAN/INDEX.HTM. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | | CONTACT ME. | | | | | | MAGGIE CRUZ, ASSOCIATE PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: (561) 822-1444 OR (561) 805-6720 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2008-09-18 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2008-09-18 |
Time |
16:28 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2008-09-18 |
Time |
16:09 |
Sent To |
I |
|
| Notes |
| 2008-09-18 16:28:16 | ***ZONING FAILED*** | | | | | | 1. PLEASE PROVIDE ALL RESPONSES IN WRITING. | | | | | | 2. PROVIDE TWO (2) COPIES OF A CURRENT SURVEY, WHICH | | | INCLUDES THE PROPERTY'S ADDRESS AND LEGAL DESCRIPTION. | | | | | | 3. PROVIDE BREAKDOWN OF EXISTING VERSES PROPOSED | | | PARKING SPACES. | | | | | | 3. PROVIDE A DETAIL OF THE PROPOSED HANDICAP PARKING | | | SPACES. UTILIZE THE ATTACHED SPECIFICATIONS AS A GUIDE. | | | PURSUANT TO THE CITY OF WEST PALM BEACH ZONING AND LAND | | | DEVELOPMENT REGULATIONS (ZLDR), SECTION | | | 94-485(O)(2)(A): ALL SPACES SHALL HAVE ACCESS TO A CURB | | | RAMP OR CURB CUT, WHEN NECESSARY, TO ALLOW ENTRANCE TO | | | THE BUILDING SERVED. SPACES SHALL BE LOCATED SO THAT | | | USERS ARE NOT COMPELLED TO WALK OR OTHERWISE MOVE | | | BEHIND PARKED VEHICLES, EXCLUDING OTHER VEHICLES PARKED | | | IN ADJACENT PARKING SPACES FOR THE DISABLED. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | | CONTACT ME. | | | | | | MAGGIE CRUZ, ASSOCIATE PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: (561) 822-1444 OR (561) 805-6720 | | | E-MAIL: [email protected] | | | |
|
|