| Plan Review Stops For Permit 08090337 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2009-02-05 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-02-05 |
Time |
11:08 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2009-02-05 |
Time |
11:08 |
Sent To |
|
|
| Notes |
| 2009-02-05 11:10:41 | RESION | | | "E" 1-14-09 SHEETS A-1, A2 RELOCATED WALLS IN ROOMS 101 | | | & 113. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2008-11-04 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-11-04 |
Time |
14:48 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2008-11-04 |
Time |
14:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-10-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-10-07 |
Time |
11:29 |
Rev Time |
0.88 |
| Received By |
jwitmer |
Date |
2008-10-07 |
Time |
11:29 |
Sent To |
|
|
| Notes |
| 2008-10-07 11:44:15 | BUILDING PLAN REVIEW | | | PERMIT: 08090337 | | | ADD: 1601 FORUM PLACE# 400 | | | CONT: ANDERSON-MOORE | | | TEL: (561)662-1819 | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW | | | ACTION: DENIED | | | | | | 1A) INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE | | | INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | 1B)INFORMATIONAL FL S S 713.13 NOTICE OF COMMENCEMENT, | | | TO BE FILED WITH THE CLERK OF THE COURT. NOTE: | | | 713.13(2) IF THE WORK DESCRIBED IN THE NOTICE OF | | | COMMENCEMENT IS NOT ACTUALLY COMMENCED WITHIN 90 DAYS | | | AFTER THE RECORDING THEREOF, SUCH NOTICE IS NULL & | | | VOID. NOTE: 713.13(6) THE POSTING OF THE NOTICE OF | | | COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE THE FIRST | | | INSPECTION. | | | | | | 1C) INFORMATIONAL: PLANS SUBMITTED FOR PERMIT (FIRST | | | TIME REVIEW) AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO | | | THE 2004 FBC BUILDING WITH THE 2007 SUPPLEMENTS THE | | | COVER- SHEET REFERENCED STANDARDS INDICATES THE 2006 | | | REVISIONS PLEASE CORRECT. | | | | | | 2) SHEET A-3 ACCESSIBLITY NOTES: THE ACCESSIBILITY NOTE | | | FOR THE SINK BASE CABINET DOES NOT MAKE IT CLEAR THAT | | | THE DOORS BENEATH THE SINK ARE TO BE REMOVED TO MAKE | | | THE SINK AN ACCESSIBLE SINK FOR A FRONT APPROACH. | | | 11-4.24.5 CLEAR FLOOR SPACE. A CLEAR FLOOR SPACE AT | | | LEAST 30 INCHES BY 48 INCHES (760 MM BY 1219 MM) | | | COMPLYING WITH SECTION 11-4.2.4 SHALL BE PROVIDED IN | | | FRONT OF A SINK TO ALLOW FORWARD APPROACH. THE CLEAR | | | FLOOR SPACE SHALL BE ON AN ACCESSIBLE ROUTE AND SHALL | | | EXTEND A MAXIMUM OF 19 INCHES (485 MM) UNDERNEATH THE | | | SINK. | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2009-02-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-02-19 |
Time |
14:59 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-02-19 |
Time |
14:59 |
Sent To |
|
|
| Notes |
| 2009-02-19 14:59:39 | REV E-2 AND 3 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2008-11-04 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-11-04 |
Time |
16:21 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-11-04 |
Time |
16:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2008-10-06 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-10-06 |
Time |
16:22 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-10-06 |
Time |
16:22 |
Sent To |
|
|
| Notes |
| 2008-10-06 16:22:48 | | | | ** DENIED REVIEW ** | | | | | | 1) NOTE: BASED ON MECHANICAL COMMENTS THERE WILL BE A | | | NEED TO REVISE ELECTRICAL PLANS FOR DUCT SMOKE | | | DETECTORS. | | | | | | 2) NOTE: THE OVER CURRENT PROTECTION FROM PANEL *H* TO | | | TRANSFORMER IS TOO HIGH PER 450.3 | | | PLEASE SEE 240.6 FOR THE NEXT HIGHER STANDARD. | | | PLANS CALL FOR RE-USING A 45K TRANSFORMER. | | | | | | | | | | | | | | | **IMPORTANT** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | | TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANOR PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2009-02-19 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2009-02-19 |
Time |
15:50 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2009-02-19 |
Time |
15:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2008-11-04 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-11-04 |
Time |
16:52 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-11-04 |
Time |
16:34 |
Sent To |
|
|
| Notes |
| 2008-11-04 16:52:10 | *****APPROVED***** | | | | | | THE COMMENTS FROM THE PREVIOUS REVIEW HAVE BEEN | | | ADDRESSED; PLAN SHEETS A-1, A-2, A-4, FP-1, AND E-2 & | | | E-3 WERE STAMPED, INITIALED, AND DATED. | | | | | | | | | | | | | | | | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2008-10-21 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-10-21 |
Time |
15:20 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-10-21 |
Time |
14:21 |
Sent To |
|
|
| Notes |
| 2008-10-21 15:19:55 | *****DENIED***** | | | | | | | | | 1. FLORIDA FIRE PREVENTION CODE 2004 EDITION SHALL BE | | | REFERENCED, NOT 2002 AS LISTED IN THE REFERENCED | | | STANDARDS ON COVER SHEET T. | | | | | | 2. STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241. | | | | | | 3. COMBUSTIBLE WASTE MATERIALS, DUST, AND DEBRIS SHALL | | | BE REMOVED FROM THE SITE AT THE END OF EACH DAY OR MORE | | | FREQUENTLY AS NECESSARY FOR SAFE OPERATION. | | | | | | 4. THE SCOPE OF WORK SHALL NOT HINDER OR INTERFERE WITH | | | ACCESS TO / EGRESS FROM THE SAID FLOOR OR THE BUILDING. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING HOW EACH ITEM WAS ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2009-01-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-01-28 |
Time |
10:36 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-01-28 |
Time |
10:36 |
Sent To |
|
|
| Notes |
| 2009-01-28 10:42:01 | TO "COMM" BD#51 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-11-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-11-03 |
Time |
09:45 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-11-03 |
Time |
09:45 |
Sent To |
|
|
| Notes |
| 2008-11-03 09:49:04 | TO "COMM" BD#31 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-10-21 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-10-21 |
Time |
14:21 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-09-15 |
Time |
14:54 |
Sent To |
|
|
| Notes |
| 2008-09-15 14:56:53 | TO "COMM" BD#42 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2009-02-21 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-02-21 |
Time |
17:38 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-02-21 |
Time |
17:37 |
Sent To |
PC |
|
| Notes |
| 2009-02-21 17:38:10 | REVISED M-2 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2008-11-15 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-11-15 |
Time |
14:51 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-11-15 |
Time |
14:33 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2008-09-23 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-09-23 |
Time |
11:12 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-09-22 |
Time |
16:57 |
Sent To |
|
|
| Notes |
| 2008-09-23 11:12:16 | REVIEW #: 1ST | | | ACTION: DENIED | | | | | | FBC 2004 CODE FAMILY W/ 2007 SUPPLEMENTS | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | 1. PAGE M-2: FLOOR PLANS SHOWS DUCT SMOKE DETECTOR ONLY | | | ON HP-5. HOWEVER, ALL HEAT PUMPS IN THIS SPACE SHARE A | | | COMMON RETURN AIR PLENUM. THEREFORE, EACH UNIT SHALL BE | | | PROTECTED BY DUCT SMOKE DETECTOR IN ACCORDANCE WITH | | | FBCM 606.2.2. | | | NOTE: DUCT SMOKE DETECTORS SHALL BE CONNECTED TO THE | | | BUILDING FIRE ALARM SYSTEM IN ACCORDANCE WITH FBCM | | | 606.4.1. | | | | | | 2. OUTSIDE AIR INTAKES SHALL BE PROVIDED WITH SHUTOFF | | | DAMPER CONTROLS IN ACCORDANCE WITH FBCB | | | 13-409.1.ABC.3.3. | | | | | | 3. EACH HYDRONIC HEAT PUMP SHALL HAVE A TWO-POSITION | | | AUTOMATIC VALVE INTERLOCKED TO SHUT OFF WATER FLOW WHEN | | | THE COMPRESSOR IS OFF IN ACCORDANCE WITH FBCB | | | 13-411.1.ABC.1.4. | | | | | | 4. PAGE M-3 CEILING DIFFUSER DETAIL PLACES A MAXIMUM | | | LENGTH LIMIT OF 8 FEET FOR FLEXIBLE DUCTS. SEVERAL FLEX | | | DUCTS ON FLOOR PLAN (PAGE M-2) ARE SHOWN TO BE WELL IN | | | EXCESS OF THIS LIMIT. PLEASE COORDINATE DETAILS AND | | | FLOOR PLANS AND CLARIFY THE INTENT. FBCM 603.1 AND FBCB | | | 106.1.1 | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2008-11-14 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-11-14 |
Time |
07:39 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-11-14 |
Time |
07:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2008-09-17 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-09-17 |
Time |
07:17 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-09-16 |
Time |
12:57 |
Sent To |
|
|
| Notes |
| 2008-09-17 07:52:02 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 11 | | | | | | 1. SHT T REFERENCE STANDARDS SHALL INCLUDE THE 2007 | | | REVISIONS TO THE 2004 FLORIDA BUILDING CODE. | | | | | | 2. SHT A-1 DEMO NOTES #4. PLEASE SHOW WHERE THE | | | PLUMBING WASTE LINES ARE TO BE CAPPED. IN THE REMOVAL | | | OF ANY PART OF A DRAINAGE SYSTEM, DEAD ENDS SHALL BE | | | PROHIBITED. SECTION 704.5. ALL DEMO'D/CAPPED LINES | | | SHALL BE INSPECTED PRIOR TO COVERING. | | | | | | 3. SHT A-3 NOTE FOR BREAK ROOM SINK INDICATES CABINET | | | DOORS AT THE SINK. THIS IS NOT APPROVED AS DOORS SHALL | | | NOT SWING INTO THE CLEAR FLOOR SPACE REQUIRED FOR ANY | | | FIXTURE. THE SINK SHALL BE ACCESSIBLE, NOT ADAPTABLE. | | | CLEAR FLOOR SPACE SHALL BE UNOBSTRUCTED. SECTION 11-3. | | | PLEASE DELETE NOTE. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | |
|
|