Plan Review Details - Permit 08090201
Plan Review Stops For Permit 08090201
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2009-04-14 Cont ID  
Sent By rmcdouga Date 2009-04-14 Time 15:32 Rev Time 0.00
Received By rmcdouga Date 2009-04-14 Time 15:32 Sent To  
Notes
2009-04-14 16:23:22REVISION - ADDED SHEET 2A

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2008-10-06 Cont ID  
Sent By rmcdouga Date 2008-10-06 Time 08:19 Rev Time 0.00
Received By rmcdouga Date 2008-10-06 Time 07:16 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-09-15 Cont ID  
Sent By rmcdouga Date 2008-09-15 Time 16:11 Rev Time 0.00
Received By rmcdouga Date 2008-09-15 Time 16:11 Sent To Z
Notes
2008-09-15 16:57:572004 FBC W/2007 REVISIONS
 LEVEL 2 ALTERATION
  
 DENIED BY BUILDING
  
 1) SPECIFY THE APPLICABLE BUILDING CODE AND THE CORRECT
 EDITION OF ASCE 7 ON THE PLANS. SEE 2004 FBC AND ASCE
 4-02.
  
 2) NOTE 2 ON SHEET 1 OF THE PLANS SPECIFIES REPLACE ALL
 DOORS. SUBMIT 2 SETS OF PRODUCT APPROVALS FOR THE
 DOORS. RULE 9B-72.
  
 3) PLEASE CLARIFY ON THE PLANS IF THE OVERHEAD GARAGE
 DOOR IS BEING REPLACED. IF IT IS, SUBMIT PRODUCT
 APPROVALS.
  
 4) THE MEAN ROOF HEIGHT ON SHEET 1 IS INCORRECT. MEAN
 ROOF HEIGHT IS THE DISTANCE FROM GRADE TO THE AVERAGE
 HEIGHT OF THE SLOPED ROOF. SEE FBC R202 FOR BUILDING
 HEIGHT AND MEAN ROOF HEIGHT.
  
 5) SPECIFY THE CORRECT ROOF SLOPE ON SHEET 1. ROOF IS
 NOT FLAT. FBC R301.2.1
  
 6) PRODUCT APPROVALS WERE SUBMITTED FOR DOUBLE HUNG
 WINDOWS AND THE PLANS SPECIFY ALL SINGLE HUNG WINDOWS.
 PLEASE CLARIFY.
  
 7) THE PRODUCT APPROVAL STATE COVERSHEET FOR THE DOUBLE
 HUNG WINDOWS IS NOT THE CORRECT ONE. IT IS FOR THE 2007
 FBC AND IT HAS A PENDING STATUS. THE ONE FOR THE 2004
 FBC IS REQUIRED. DCA RULE 9B-72.
  
 8) THE MINIMUM WALL INSULATION FOR A 2 X 6 WALL IS R-19
 PER FBC 13-600. REVISE THE R VALUE SPECIFIED WALL
 SECTION B ON SHEET 2.
  
 9) PROVIDE A STRUCTURAL DETAIL OF THE BAY WINDOW
 INDICATING HOW THE DOUBLE 2 X 8 HEADER ABOVE THE
 WINDOWS WILL BE SUPPORTED AND HOW THEY WILL BE ATTACHED
 TO THE EXISTING TIE BEAM. SPECIFY HOW LOADS WILL BE
 TRANSFERRED TO THE FOUNDATION. FBC R301.1.
  
 10) SPECIFY THE REQUIRED LOAD BEARING CAPACITY OF THE
 SOIL ON THE PLANS FOR THE NEW BAY WINDOW FOUNDATION.
 FBC R 403.1
  
 11) SHOW COMPLIANCE WITH R320.1 FOR PROTECTION AGAINST
 TERMITES ON THE PLANS AT THE NEW BAY WINDOW.
  
 12) IF THE DOORS AND OVERHEAD GARAGE DOOR ARE BEING
 REPLACED SPECIFY THE POSITIVE AND NEGATIVE OPENING
 PRESSURES FOR THEM ON THE PLANS. FBC R301.2.1
  
 13) THE VALUE OF THE WORK SPECIFIED ON THE APPLICATION
 APPEARS TO BE LOW. THE VALUE IS TO INCLUDE THE COST OF
 MATERIALS, LABOR, ELECTRIC, PLUMBING, FIXTURES,
 CABINETS, DESIGN COSTS, OVERHEAD AND PROFIT AS A
 CONTRACTOR WOULD CHARGE. PLEASE ADJUST THE VALUE ON THE
 APPLICATION.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2008-09-30 Cont ID  
Sent By dpalmer Date 2008-09-30 Time 16:52 Rev Time 0.00
Received By dpalmer Date 2008-09-30 Time 16:52 Sent To M
Notes
2008-09-30 16:54:23REDLINED PLANS
  
 LOADS FOR DINING ROOM WERE NOT ADDED PER
 210.52B1,210.11C1,220.52 AS NOTED ON PREVIOUS REVIEW.
 THIS ADDITIONAL LOAD OF 1500VA WILL NOT AFFECT THE
 SERVICE HOWEVER WILL NEED TO BE REVISED BEFORE FINAL.
 IF THERE ARE REVISIONS MADE BEFORE ROUGH, PLEASE REVISE
 AT THAT TIME.
  
 IF THERE ARE ANY QUESTIONS PLEASE CONTACT.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVEIW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2008-09-11 Cont ID  
Sent By dpalmer Date 2008-09-11 Time 14:25 Rev Time 0.00
Received By dpalmer Date 2008-09-11 Time 14:25 Sent To M
Notes
2008-09-11 14:25:31 
  
 ** DENIED REVIEW **
  
  
  
 1) NOTE: PLEASE VERIFY SCOPE OF WORK AS PERMIT
 APPLICATION STATES TO UPDATE ALL ELECTRICAL YET THE
 PLANS INDICATE MUCH OF IT AS EXISTING?
 FBC 106.1.1 FOR CLARITY OF SCOPE.
  
 IF APPLICATION STATES TO UPDATE ELECTRICAL HOW CAN THE
 PLANS SHOW SEVERAL ROOMS WITH NO ELECTRICAL?
  
 2) NOTE: PLEASE SEE 210.52B1, 210.11C1, 220.52 AS THE
 DINING ROOM RECEPTACLES SHALL NOT BE PART OF FAMILY
 ROOM CIRCUIT AND SHALL MEET THE OTHER SECTIONS AS
 NOTED.
 PANEL SCHEDULE SHOWS 15AMP BREAKER AND #14 WHICH IS NOT
 PERMITTED.
  
 2) NOTE: PLEASE LIST ALL OF THE ARC FAULT PROTECTED
 CIRCUITS ON PANEL SCHEDULE PER 210.12,408.4.
 NONE LISTED AT THIS TIME. *** GFCI IS NOT THE SAME AS
 AFCI***
  
 3) NOTE: PLEASE SEE 250.24, 250.6 AS NO EQUIPMENT
 GROUNDING CONDUCTORS ARE PERMITTED BEFORE THE FIRST
 MEANS OF DISCONNECT.
  
  
 **IMPORTANT**
 ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP
 FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE
 ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING.
 DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS.
 PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY
 ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS,
 SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO
 TWO SETS/FOLDERS/BINDERS ETC.
 PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS
 SHOULD BE SUBMITTED FOR REFERENCE.
 THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID
 ANY DELAYS.
  
 IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT
 TYPED IN A CLEAR MANOR PLEASE DO NOT HESITATE TO
 CONTACT THIS REVIEWER.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-09-25 Cont ID  
Sent By adarroug Date 2008-09-25 Time 11:23 Rev Time 0.00
Received By adarroug Date 2008-09-25 Time 11:23 Sent To E
Notes
2008-09-25 11:24:00TO "DPALMER" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-09-16 Cont ID  
Sent By rmcdouga Date 2008-09-16 Time 08:41 Rev Time 0.00
Received By rmcdouga Date 2008-09-10 Time 14:32 Sent To  
Notes
2008-09-10 14:32:35TO "SFR" "E"

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2008-10-01 Cont ID  
Sent By tgordon Date 2008-10-01 Time 10:00 Rev Time 0.30
Received By tgordon Date 2008-10-01 Time 10:00 Sent To P
Notes
2008-10-01 10:00:45BATHROOM EXHAUST FAN ONLY.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2008-09-15 Cont ID  
Sent By tgordon Date 2008-09-15 Time 08:22 Rev Time 0.30
Received By tgordon Date 2008-09-15 Time 08:22 Sent To P
Notes
2008-09-15 08:24:55PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM
 BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA
 ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES
 (F.S.).
  
 *** DENIED ***
  
 1) BATHROOM #2 ON THE SECOND FLOOR WILL REQUIRE AN
 EXHAUST FAN, PER 2004 FBC/R R303.3. PLEASE CORRECT.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]

Review Stop P PLUMBING
Rev No 2 Status P Date 2008-10-01 Cont ID  
Sent By mperson Date 2008-10-01 Time 11:20 Rev Time 0.00
Received By mperson Date 2008-10-01 Time 11:20 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2008-09-15 Cont ID  
Sent By mperson Date 2008-09-15 Time 14:34 Rev Time 1.00
Received By mperson Date 2008-09-15 Time 14:34 Sent To B
Notes
2008-09-15 15:27:18PLUMBING PLAN REVIEW:
 DENIED:
  
 PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH
 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO
 CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE
 (F.A.C.), AND FLORIDA STATUTES (F.S.).
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE.
  
 1. DECLARE THE GOVERNING CODE. (FBC-2004 WITH 2007
 REVISIONS). PER (W.P.B. AS AMENDED) SECTION 106.5
 RETENTION OF CONSTRUCTION DOCUMENTS.
  
 2. SHEET 1 OF 2, NOTES #12 INDICATES THAT THE KITCHEN
 CABINETS AND COUNTER TOPS ARE BEING REPLACED, HOWEVER
 THERE IS NO INDICATION OF THE SINK BEING REPLACED.
 PLEASE CLARIFY IF THE EXISTING SINK IS BEING REUSED OR
 IF A NEW ONE IS BEING INSTALLED.PER FBC-2004 PLUMBING
 SECTION 401.1 SCOPE.
  
 3. SHEET 2 OF 3, SANITARY PLUMBING RISER: PLEASE
 CORRECT THE FOLLOWING PER THE FBC-2004 PLUMBING
 SECTIONS.
  
 A} THE SUBMITTED RISER DIAGRAM DOES NOT REFLECT THE
 FLOOR PLAN. THE 2ND FLOOR LAVATORY IS BEING INDICATED
 BETWEEN THE WATER CLOSET AND TUB, HOWEVER THE FLOOR
 PLAN IS INDICATING THE LAVATORY TO THE SIDE OF THE
 WATER CLOSET. AT A MINIMUM THE SANITARY RISER SHALL
 REFLECT THE PROPOSED FLOOR PLAN. PER SECTION 701.1
 SCOPE AND (W.P.B. AS AMENDED) SECTION 106.3.5.4(9)
 PLUMBING.
  
 B} A 3 INCH SOIL STACK IS REQUIRED FOR THE NEW PROPOSED
 2ND FLOOR PLAN PLUMBING. PER SECTION 701.1 SCOPE AND
 (W.P.B. AS AMENDED) SECTION 106.3.5.4(9) PLUMBING.
  
 C} A 3 INCH CLEAN OUT IS REQUIRED AT THE BASE OF THE
 SOIL STACK FOR THE 2ND FLOOR PLUMBING. PER SECTION
 708.3.4 BASE OF STACK.
  
 D} A VENT IS REQUIRED FOR THE 2ND FLOOR MASTER BATH
 TUB. PER A 1/4" = 1' SCALE THE TUB POINT OF VENT
 APPEARS TO BE ABOUT 9 FEET FROM TRAP. PER TABLE 906.1,
 A 2 INCH TRAP CAN ONLY BE 6 FEET FROM VENT.
  
 4. SHEET 2 OF 2, 2ND FLOOR DEMOLITION PLAN: CLEARLY
 INDICATE THE FOLLOWING ON THE DEMO PLAN PER FBC-2004
 PLUMBING, SECTION 704.5 DEAD ENDS: IN THE REMOVAL OF
 ANY PART OF A DRAINAGE SYSTEM, DEAD ENDS SHALL BE
 PROHIBITED. A PLUMBING PERMIT IS REQUIRED AND AN
 INSPECTION IS REQUIRED OF PLUMBING DEMO WORK PRIOR TO
 COVERING DEMO WORK WITH FINNISH WALLS, CIELINGS, OR
 POURED CONCRETE SLABS.
  
 ********IMPORTANT INFORMATION********
 WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE
 OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW
 PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 END OF COMMENTS:
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 PHONE= (561) 805-6730
 FAX= (561) 805-6731
 E-MAIL= [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2008-09-16 Cont ID  
Sent By mcruz Date 2008-09-16 Time 10:31 Rev Time 0.00
Received By mcruz Date 2008-09-16 Time 10:31 Sent To  
Notes
***NONE***