| 2008-09-26 15:00:58 | RESIDENTIAL (R3) RAISED WOOD DECK, BUILDING REVIEW |
| | CHECKLIST. |
| | REVIEW UNDER 2004 FLORIDA RESIDENTIAL CODE. |
| | |
| | 1- NEED RECORDED NOTICE OF COMMENCEMENT AS REQUIRED BY |
| | SEC. 713.13 FLORIDA STATUTE. |
| | |
| | 2- SPECIFY DECK HEIGHT TO VERIFY IF GUARDRAILS WILL BE |
| | REQUIRED. GUARDRAILS ARE REQUIRED FOR DECKS THAT ARE |
| | LOCATED MORE THAN 30" ABOVE GRADE. SEC. R312 OF 2004 |
| | FLORIDA RESIDENTIAL CODE. |
| | |
| | 3- CLEARLY SPECIFY ON PLANS SPECIFIC ANCHOR TYPE AND |
| | SIZE TO BE USED. SPECIFY NAME OF CONNECTORS AND SIZE. |
| | EG: SPECIFY SIZE AND LOCATION OF JOIST HANGERS, JOIST |
| | BRACERS, 4X4 CONCRETE BRACERS, LAG BOLTS, BOLTS, ETC. |
| | SEE CATALOG FOR SPECIFIC NAME AND SIZE TO BE USED. SEC. |
| | 106.12 CITY AMENDMENTS TO FBC 2004 TO VERIFY COMPLIANCE |
| | WITH UPLIFT LOADS OF SEC. R301 OF 2004 FLORIDA |
| | RESIDENTIAL CODE. |
| | |
| | 4- PROVIDE COMPLETE SPECIFICATIONS FOR FOOTERS. SPECIFY |
| | SIZE AND REINFORCEMENT. ALSO, SPECIFY HOW MUCH IS |
| | EMBEDDED INTO THE SOIL TO VERIFY COMPLIANCE WITH SEC. |
| | R403.1.4 OF 2004 FLORIDA RESIDENTIAL CODE. NEEDS TO BE |
| | 12" EMBEDDED INTO GRADE. |
| | |
| | 5- PROVIDE FLORIDA PRODUCT APPROVAL AS REQUIRED BY DCA |
| | RULE 9B-72 FOR ALL STRUCTURAL CONNECTORS SPECIFIED ON |
| | PLANS/DETAILS. GO TO WWW.FLORIDABUILDING.ORG TO FIND |
| | OUT ALL PRODUCT APPROVALS. PROVIDE ONLY THE COVER PAGE |
| | OF THE PRODUCT APPROVAL AND THE PAGE WHERE THE |
| | CONNECTOR IS SHOWN. |
| | |
| | 6- PERSON WHO DESIGNED THE PLANS NEED TO WRITE HIS NAME |
| | AND SIGN DRAWINGS. |
| | |
| | JULIO GOMEZ |
| | BUILDING PLANS EXAMINER |
| | (561)805-6712 |