| Plan Review Stops For Permit 08090018 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2009-07-25 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2009-07-25 |
Time |
13:06 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2009-07-25 |
Time |
13:06 |
Sent To |
|
|
| Notes |
| 2009-07-25 13:08:25 | APPROVED FOR ACCESSORY USE ONLY, NOT FOR HABITATION. | | | LM |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2009-05-05 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2009-05-05 |
Time |
16:44 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2009-05-05 |
Time |
16:44 |
Sent To |
|
|
| Notes |
| 2009-05-05 16:55:04 | BUILDING REVIEW COMMENTS | | | | | | | | | | | | PLEASE REFERENCE 2004 FBC (RESIDENTIAL) AND ASCE 7-02 | | | AS THE CODE DESIGN AND ANY GENERAL NOTE SECTIONS. NOTES | | | CAN BE ALTERED AND INITIALED BY MR. BUCK ONLY, IN LIEU | | | OF DRAWING NEW SHEETS. | | | | | | | | | | | | LUIS MARTINEZ | | | 561-8052-6710 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-09-20 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2008-09-20 |
Time |
08:34 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2008-09-20 |
Time |
08:34 |
Sent To |
PC |
|
| Notes |
| 2008-09-20 09:06:37 | | | | | | | DENIED | | | | | | 1) PLANS AND SPECIFICATIONS DESIGN PARAMETERS SHALL | | | COMPLY WITH THE 2004 FLORIDA BLDG CODE WITH 2006 | | | AMENDMENTS | | | | | | 2) CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT | | | CLARITY TO INDICATE THE LOCATION,NATURE, AND EXTENT OF | | | THE WORK PROPOSED AND SHOW IN DETAIL THAT IT WILL | | | CONFORM TO THE PROVISIONS OF THIS CODE PER 106.1.1 FBC* | | | | | | 3) PROVIDE WIND DESIGN DATA ON DRAWINGS PER 1603.1.4 | | | FBC. PLEASE NOTE THE 2006 AMENDMENTS TO THE 2004 FBC | | | REQUIRE BUILDINGS LOCATED WITHIN EXP B TYPE TERRAIN | | | THAT IS DIRECTLY ADJACENT TO EXP C TYPE TERRAIN SUCH AS | | | OPEN GOLF COURSES AND BODIES OF WATER FOR A DISTANCE OF | | | 600 FEET OR MORE IN ANY QUADRANT TO BE IN AN EXP C | | | CATEGORY. PLEASE ADJUST THE DESIGN PARAMETERS AND WIND | | | PRESSURES ACCORDINGLY | | | | | | 2) PER R301 FBC RES. THE FOLLOWING DESIGN CRITERIA IS | | | REQUIRED ON THE CONSTRUCTION DOCUMENTS SUBMITTED FOR | | | PERMIT, BUILDINGS AND STRUCTURES, AND ALL PARTS | | | THEREOF, SHALL BE CONSTRUCTED TO SAFELY SUPPORT ALL | | | LOADS, INCLUDING DEAD LOADS, LIVE LOADS, ROOF LOADS, | | | FLOOD LOADS AND WIND LOADS AS PRESCRIBED BY THIS CODE. | | | THE CONSTRUCTION OF BUILDINGS AND STRUCTURES SHALL | | | RESULT IN A SYSTEM THAT PROVIDES A COMPLETE LOAD PATH | | | CAPABLE OF TRANSFERRING ALL LOADS FROM THEIR POINT OF | | | ORIGIN THROUGH THE LOAD-RESISTING ELEMENTS TO THE | | | FOUNDATION. | | | | | | 3) THE PERMIT APPLICATION SHALL INCLUDE TWO COPIES OF | | | EACH PRODUCT APPROVAL THAT IS RELEVANT PER 9B-72. THIS | | | SHALL INCLUDE ROOFING MATERIALS, DOORS,WINDOWS, | | | STRAPS/CONNECTOR, ETC. | | | | | | 4) PER SECTION 1609.1.4 FBC OPENING PROTECTION IS | | | REQUIRED, ALL GLAZED OPENING SHALL MEET LARGE MISSILE | | | IMPACT TEST | | | | | | 5) ADDITIONAL PERMITS WILL BE REQUIRED FOR ELECTRICAL | | | AND ROOFING | | | | | | 6) PROVIDE ROOF FRAMING INFORMATION AND LAYOUT, IS THIS | | | ROOF FRAMED OF TRUSS,IF TRUSSES ARE USED SUBMIT 2 | | | COPIES OF ENGINEERED TRUSS DRAWINGS THAT COMPLY WITH | | | R802.10.1 FBC WITH PERMIT APPLICATION OR BEFORE | | | INSTALLATION. | | | | | | 7) PROVIDE MIN ROOF SHEATHING ATTACHMENT | | | PER R803.2.3.1 FBC RES. | | | | | | 8) DRAWINGS INCOMPLETE, ELEVATIONS AND PLAN VIEWS DO | | | NOT RELATE NO BAY WINDOWS SHOWN ON PLAN. NO PORCH ROOF, | | | PROVIDE WINDOW AND DOOR SIZES, OVERALL DIMENSIONS. MEAN | | | ROOF HEIGHT, ETC. | | | | | | 9) WHEN COMPLETE DRAWINGS AND PRODUCT APPROVALS ARE | | | SUBMITTED FURTHER COMMENTS MAY ARISE | | | | | | NOTE: FBC = FLORIDA BUILDING CODE 2004 W/2006&2007 | | | AMENDMENTS | | | FBC* = WEST PALM BEACH ADMINISTRATIVE | | | AMENDMENTS TO FBC | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | FBC RES. = FLORIDA BUILDING CODE RESIDENTIAL 2004 | | | W/2006&2007 AMENDMENTS | | | | | | BLDG PLAN REVIEW | | | ADRIAN MORSE | | | 561-805-6716 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
N |
Date |
2009-08-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-08-07 |
Time |
09:41 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-08-07 |
Time |
09:41 |
Sent To |
|
|
| Notes |
| 2009-08-07 09:42:22 | AT THE OWNER'S REQUEST. | | | ALL ELECTRICAL TO BE SUBMITTED UNDER SEPARATE PLANS, | | | PERMIT APPLICAITON AND FEE. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2009-06-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-06-10 |
Time |
16:18 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-06-10 |
Time |
16:18 |
Sent To |
|
|
| Notes |
| 2009-06-10 16:19:07 | ** DENIED 3RD REVIEW** | | | | | | | | | ** ONE SET OF PLANS ARE BEING RETAINED BY THIS OFFICE. | | | MINIMUM CODE COMPLIANCE IS NOT BEING MET WITH REPEATED | | | COMMENTS. FS 553.80(2)(B) MAY BE ASSESSED ON THE | | | FOLLOWING REVIEW TO DESIGNER OF RECORD. | | | | | | ** PLANS ARE REVISED SHOWING A COMPLETELY DIFFERENT | | | SERVICE FROM PREVIOUS SUBMITTED PLANS. SEE NOTES BELOW | | | AS *MINIMUM* CODE COMPLIANCE IS NOT MET. | | | IF PLANS ARE REVISED AND ARE NOT THE SAME AS PREVIOUSLY | | | SUBMITTED THEN SOMETIMES THAT CAN CREATE NEW COMMENTS | | | ** THIS REVIEWER HAS STATED ON BOTH PREVIOUS REVIEWS | | | THAT IF THERE WERE QUESTIONS TO PLEASE CALL TO GO OVER | | | COMMENTS. TO DATE NO CONTACT HAS BEEN MADE TO THIS | | | OFFICE TO GO OVER COMMENTS. | | | SEE ALL OF THE FOLLOWING NOTES. | | | | | | 1) NOTE: NEW RISER NOW SHOWS EXISTING 200AMP METER WITH | | | NEW 4/0 ON RISER YET THE CONDUCTORS TO MAIN ARE 2/0. | | | WHICH IS IT? 310.16, 310.15B6 | | | | | | 2) NOTE: THE RISER NOW SHOWS A NEW SERVICE MAIN WITH A | | | 200AMP DISCONNECT AND A NEW 60 AMP DISCONNECT. AS SHOWN | | | THIS IS A 260AMP SERVICE. CONDUCTORS AND METER ARE NOT | | | RATED FOR MORE THAN 200AMPS. IS THIS A MAIN BREAKER | | | PANEL WITH A SUB 60AMP BREAKER? | | | | | | 3) NOTE: PLEASE INDICATE AIC RATINGS FOR NEW MAIN PER | | | 110.9 | | | | | | 4) NOTE: THE RISER NOW SHOWS NEW #1AWG CONDUCTORS FROM | | | 60AMP BREAKER AS NEW FEEDERS TO SUB PANEL AT PLAYHOUSE. | | | THIS IS NOT POSSIBLE. 110.14,110.3 | | | | | | 5) NOTE: THE RISER NOW SHOWS A NEW 60AMP SUB PANEL AT | | | THE PLAYHOUSE YET THE EXISTING 200AMP PANEL STILL SHOWS | | | TWO CIRCUITS TO THE NEW PLAYHOUSE. WHICH IS IT? | | | IN EITHER CASE THE MEANS OF DISCONNECT REQUIRED PER | | | 225.31-225.39 IS NOT SHOWN AS PREVIOUSLY REQUESTED ON | | | BOTH PREVIOUS REVIEWS. | | | | | | 6) NOTE: THE GROUNDING ELECTRODE SYSTEM BASED ON | | | 250.32, 250.50, 250.66 IS STILL NOT SHOWN. IF THERE IS | | | A NEW PANEL PLEASE SHOW THE MINIMUM. IF THERE NEW | | | CIRCUITS FROM EXISTING PANEL THEN PLEASE SHOW | | | COMPLIANCE. FOR NOTES #5 AND #6. | | | | | | 7) NOTE: IF THERE IS GOING TO BE A NEW SUB PANEL INSIDE | | | THE NEW PLAYHOUSE PLEASE SUBMIT THE PANEL SCHEDULE | | | SHOWING MINIMUM CODE COMPLIANCE FOR CONDUCTOR SIZES, | | | OVER CURRENT PROTECTION AND PANEL SCHEDULE. | | | 240.4,408.4, 310.16 ETC | | | | | | | | | | | | | | | | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED | | | INTO TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2009-03-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-03-24 |
Time |
09:04 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-03-24 |
Time |
09:04 |
Sent To |
B |
|
| Notes |
| 2009-03-24 09:05:13 | ** PLANS DENIED ** | | | | | | THE ELECTRICAL PLANS DO NOT MEET THE MINIMUM NATIONAL | | | ELECTRICAL CODE. PLEASE SEE THE FOLLOWING COMMENTS. | | | THESE COMMENTS ARE BASED ON THE 2005 NFPA-70 | | | | | | 1) NOTE: THE ELECTRICAL RISER SUBMITTED DOES NOT MEET | | | MINIMUM CODE. THE RISER INDICATES A 200AMP DISCONNECT | | | FEEDING CONDUCTORS ONLY RATED FOR 150AMPS PER 310.15B6. | | | THIS RISER ALSO INDICATES A SECONDARY FEEDER FROM THE | | | MAIN TO THE PANEL. WHICH IS CORRECT? | | | | | | 2) NOTE: PLEASE SEE NEC 225.31-225.39 REQUIRED | | | DISCONNECTING MEANS NOT SHOWN. REQUIRED GROUPING ETC. | | | | | | 3) NOTE: PLEASE SEE 250.32, 250.50 AS THE REQUIRED | | | IDENTIFICATION OF THE GROUNDING ELECTRODE SYSTEM IS NOT | | | SHOWN. | | | | | | 4) NOTE: PLEASE BE SURE TO STATE THE ADOPTED MINMUM | | | CODE EDITIONS ON PLANS AS REQUIRED PER FS 553.73. | | | 2004 FBC (RESIDENTIAL AND 2005 NFPA-70 | | | | | | | | | | | | ** IMPORTANT ** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED | | | INTO TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2008-09-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-09-12 |
Time |
16:06 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-09-12 |
Time |
16:06 |
Sent To |
|
|
| Notes |
| 2008-09-12 16:06:44 | | | | | | | | | | | | | ** DENIED REVIEW ** | | | | | | 1) NOTE: PLEASE SUBMIT PLANS WITH MINIMUM CLARITY AND | | | INFORMATION IN DRAFTSMAN QUALITY. THE PLANS NEED TO | | | SHOW ALL ASPECTS OF CONSTRUCTION TO CONFORM TO THE | | | MINIMUM BUILDING CODE ALONG WITH OTHER ADOPTED CODES BY | | | FLORIDA STATUES 553.73 | | | FBC 106.1, 106.1.1, 106.1.2, 106.3.5.4. | | | | | | 2) NOTE: PLEASE SUBMIT ELECTRICAL PLANS WHICH WILL | | | COORDINATE WITH A SUBMITTED FLOOR PLAN. FOR EXAMPLE THE | | | ELECTRICAL LAYOUT AS SUBMITTED DOES NOT COORDINATE WITH | | | THE HAND DRAWN ELEVATION PLANS. THE ELEVATION PLANS | | | SHOW WALLS AND WINDOWS WHICH ARE NOT THE SAME AS | | | ELECTRICAL. | | | PLEASE SUBMIT ELECTRICAL PLANS WHICH ARE UNDER THE | | | MINIMUM DESIGN OF THE 2005 NATIONAL ELECTRICAL CODE. | | | PLEASE SEE SOME OF THE FOLLOWING. | | | LOAD CALCULATIONS FOR ADDING LOAD TO EXISTING SERVICE. | | | 220.87 | | | GROUNDING ELECTRODE SYSTEM AT DETACHED STRUCTURES PER | | | 250.32, 250.50. | | | DISCONNECTING MEANS AT DETACHED STRUCTURES PER | | | 225.31-225.39. | | | CONDUCTOR SIZES PER 310.16 | | | PANEL SCHEDULE PER 408.4 | | | BREAKER SIZE(S). 310.16, 240.4, 210.19, 210.20 ETC | | | | | | | | | *** BASED ON PLANS AT THIS TIME THERE MAY VERY WELL BE | | | NEW COMMENTS ON THE FOLLOWING REVIEW. | | | | | | | | | **IMPORTANT** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | | TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANOR PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2009-06-03 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2009-06-03 |
Time |
14:17 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2009-06-03 |
Time |
14:17 |
Sent To |
|
|
| Notes |
| 2009-06-03 14:18:29 | SENT TO RESIDENTIAL BOX R13. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2009-03-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-03-16 |
Time |
08:26 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-03-16 |
Time |
08:26 |
Sent To |
Z |
|
| Notes |
| 2009-03-16 08:27:05 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-09-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-09-10 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-09-10 |
Time |
14:54 |
Sent To |
E |
|
| Notes |
| 2008-09-10 15:00:05 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2008-09-20 |
Time |
|
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-09-03 |
Time |
12:41 |
Sent To |
|
|
| Notes |
| 2008-09-03 12:41:53 | TO "Z" BOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2009-03-17 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2009-03-17 |
Time |
10:03 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2009-03-17 |
Time |
10:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2008-09-09 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2008-09-09 |
Time |
09:26 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2008-09-09 |
Time |
09:26 |
Sent To |
|
|
| Notes |
| 2008-09-09 09:30:21 | ***FAILED*** | | | | | | 1) OVERALL HEIGHT OF THE STRUCTURE SHALL BE PROVIDED. | | | BUILDING HEIGHT SHALL BE MEASURED FROM GRADE TO THE | | | MEAN POINT OF THE PITCHED ROOF. | | | | | | 2) A FLOOR PLAN SHALL BE PROVIDED, OR THE DIMENSIONS OF | | | THE STRUCTURE SHALL BE PROVIDED ON THE SITE | | | PLAN/SURVEY. | | | | | | 3) THE FLOOR PLAN OR REVISED SITE PLAN SHALL MATCH THE | | | BUILDING FOOTPRINT THAT IS BEING PROPOSED AND ENSURE | | | THAT THE SETBACKS ARE MEASURED FROM THE PROPERTY LINE | | | TO THE CLOSEST POINT OF THE STRUCTURE. | | | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER, | | | AT (561) 822-1435. |
|
|