Plan Review Details - Permit 08080664
| Plan Review Stops For Permit 08080664 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2009-01-26 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-01-26 |
Time |
11:12 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2009-01-26 |
Time |
11:12 |
Sent To |
B |
|
| Notes |
| 2009-01-26 12:44:36 | BUILDING PLAN REVIEW | | | PERMIT: 08080664 | | | ADD: 1801 N FLAGLER DR | | | CONT: SEACREST SERVICES | | | TEL: (561)346-8449 | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | JAN.26/ 2009 | | | 3RD REVIEW | | | ACTION: DENIED | | | | | | 1A) INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE | | | INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | 1B) 2ND REQUEST, PLEASE SUBMIT 3 OF ALL SURVEYS, PLANS, | | | REPORTS, REVISIONS , PRODUCT APPROVALS AND OR | | | SUBMITTALS FOR REVIEW FOR PERMIT. YOUR PROJECT WILL | | | REQUIRE A THRESHOLD BUILDING REQUIRING A THRESHOLD | | | INSPECTOR THEN (3) THREE SETS OF ALL SAID DOCUMENTS | | | WILL BE REQUIRED FOR PERMIT ISSUANCE. 106.1* /2004 | | | SUBMITTAL DOCUMENTS WEST PALM BEACH ADMINISTRATIVE | | | CODE. | | | | | | 1C) COMPLIED. | | | | | | 1D)2 COMPLIED. | | | | | | 1E) 3RD REQUEST, PLANS FAIL TO INDICATE DESIGNED TO THE | | | 2004 EXISTING BUILDING CODE, CHAPTER 9 ADDITIONS. | | | | | | 2) ) 110.2* W. P. B. ADMINISTRATIVE CODE, INFORMATION | | | THAT IS REQUIRED FOR RECORD KEEPING & FOR CERTIFICATE | | | OF OCCUPANCY: | | | A) THE EDITION OFTHE CODE UNDER WHICH THE PROJECT IS | | | DESIGNED. | | | | | | B) COMPLIED. | | | | | | C) COMPLIED. | | | | | | D) 3RD REQUEST, THE RETURN COMMENTSINDICATE THAT NO | | | FIRE SPRINKLERS WILL BE INSTALLED IN THE ADDITION. | | | EXISSTING BUILDING CODE SECTION 902.3 AND 901.2 AN | | | ADDITION SHALL NOT CREATE OR EXTEND ANY NONCONFORMITY. | | | THIS BUILDING IS CONSIDERED A HIGH RISE AND SINCE THERE | | | ARE FIRE SPRINKLERS WITHIN THE BUILDING THEN THE SYSTEM | | | WILL NEED TO BE EXTENDED TO WITHIN THE ADDITION, PLEASE | | | SHOW THE EXTENSION OF THE FIRE SPRINKLER LINE. | | | | | | E) WHETHER THE SPRINKLER SYSTEM IS REQUIRED, YES | | | HIGHRISE 2004 EXISTING BUILDING CODE 901.2/ 902.3 AND | | | 2004 FBC403.2 AUTOMATIC FIRE SPRINKLER SYSTEMS. | | | | | | G-I) COMPLIED. | | | . | | | H | | | 3) THIS BUILDING IS A 9 STORY BUILDING OR CONSIDERED A | | | THRESHOLD BUILDING REQUIRING : | | | FL S. S. 553.71(7) " THRESHOLD BUILDING" MEANING ANY | | | BUILDING WHICH IS GREATER THAN (3) STORIES OR 50 FT IN | | | HEIGHT, OR WHICH HAS AN ASSEMBLY OCCUPANCY | | | CLASSIFICATION AS DENIED IN THE | | | FLORIDA BUILDING CODE WHICH EXCEEDS 5,000 SQ FT IN AREA | | | AND AN OCCUPANT CONTENT OF GREATER THAN 500 PERSONS. | | | | | | 3A) 3RD REQUEST, THE THRESHOLD INSPECTION PLAN | | | SUBMITTED IS NOT SIGNED NOR SEALED. THRESHOLD | | | INSPECTION PLAN 105.13.1 THE ENFORCING AGENCY SHALL | | | REQUIRE A SPECIAL INSPECTOR TO PERFORM STRUCTURAL | | | INSPECTIONS ON A THRESHOLD BUILDING PURSUANT TO A | | | STRUCTURAL INSPECTION PLAN PREPARED BY THE ENGINEER OF | | | RECORD. THE STRUCTURAL INSPECTION PLAN MUST BE | | | SUBMITTED TO THE ENFORCING AGENCY PRIOR TO THE ISSUANCE | | | OF A BUILDING PERMIT FOR THE CONSTRUCTION OF A | | | THRESHOLD BUILDING. THE PURPOSE OF THE STRUCTURAL | | | INSPECTION PLAN IS TO PROVIDE SPECIFIC INSPECTION | | | PROCEDURES AND SCHEDULES SO THAT THE BUILDING CAN BE | | | ADEQUATELY INSPECTED FOR COMPLIANCE WITH THE PERMITTED | | | DOCUMENTS. | | | | | | 3B)3RD REQUEST, THRESHOLD INSPECTOR: WPB AMENDMENT | | | 105.13.6. W.P.B. CONSTRUCTION SERVICES DEPARTMENT | | | REQUEST FOR THRESHOLD BUILDINGS A SPECIAL INSPECTOR AS | | | REQUIRED BY FL S S 553.79(5) FLORIDA STATUTES TO THE | | | MINIMUM INSPECTIONS REQUIRED BY THIS CODE. CONTACT KEN | | | CONRAD MANAGER OF THE SPECIAL INSPECTOR PROGRAM AT | | | (561)805-6666 FOR FURTHER INFORMATION BEFORE THE PERMIT | | | MAY BE ISSUED. | | | SEE ATTACHMENT FOR FORMS. | | | | | | 3C) COMPLIED. | | | | | | 4) BUILDING PROVISO: FBC BUILDING 3110.1.2 / CITY OF | | | WPB CODE OF ORDINANCES SECTION 94-546. STRUCTURE IS | | | LOCATED IN AN "A-5" FLOOD ZONE. A FLOOD ELEVATION | | | CERTIFICATE WILL BE REQUIRED BEFORE A CERTIFICATE OF | | | COMPLETION WILL BE AWARDED.. PLEASE INDICATE THE | | | ELEVATION OF THE FLOOR SLAB. THE MINIMUM SLAB ELEVATION | | | IS 7'-6". | | | | | | 5) SPOKE WITH THE ENGINEERS FIRM TODAY AND A SIGNED AND | | | SEALED LETTER FROM THE SOILS ENGINEER WILL BE FORTH | | | COMING FOR THE ONE STORY ADDITION. PLEASE PROVIDE 3 | | | ORIGINAL SIGNED & SEALED SOILS REPORTS. 1802.2.1 | | | QUESTIONABLE SOIL. WHERE THE SAFE-SUSTAINING POWER OF | | | THE SOIL IS IN DOUBT, OR WHERE A LOAD-BEARING VALUE | | | SUPERIOR TO THAT SPECIFIED IN THIS CODE IS CLAIMED, THE | | | BUILDING OFFICIAL SHALL REQUIRE THAT THE NECESSARY | | | INVESTIGATION BE MADE. SUCH INVESTIGATION SHALL COMPLY | | | WITH THE PROVISIONS OF SECTIONS 1802.4 THROUGH 1802.6 . | | | | | | 6) COMPLIED. | | | | | | | | | 7) 3RD REQUEST, SEMI-COMPLIED. THIS BUILDING TYPE WILL | | | BE A MINIMUM OF TYPE IB PLEASE REVIEW COMBUSTIBLE/ | | | NONCOMBUSTIBLES MATERIALS ALLOWED IN 603.1 FBC. WALL | | | ASSEMBLIES ROOF FRAMING AND ROOF DECKS. | | | ROOF DECKS THE PLANS DO SHOW TTHE FLAT DECK WITH B DECK | | | GALVANIZED PANELS WWITH INSULATION AND A MANSARD STYLE | | | PERMITERE WHICH TILE ARE ATTACHED. PLANS INDICATE THE | | | USE OF 5/8" DENS-DECK FOR A SHEATHING, PLEASE NOTE THE | | | PRODUCT APPROVAL METROTILE PAGES 4-4-7 ALL INDICATE THE | | | USE ON 1/2 WOOD PLYWOOD OR WOOD PLANK. NOTE THERE IS NO | | | GALVANIZED DECK THAT THE TILE ROOF SCREWS CAN PENETRATE | | | TO ANCHOR THE ROOF TILE IN PLACE. | | | | | | 8) COMPLIED. | | | | | | 9) 3D REQUEST, 106.3* PRODUCT APPROVALS. THOSE PRODUCT | | | WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE REVIEWED | | | AND APPROVED "IN WRITING" ( SHOP DRAWING STAMP BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL. | | | | | | 10) COMPLIED. | | | | | | 11) FLAT ROOF REVIEW: THIS ROOF IS MISSING OR NOT IN | | | COMPLIANCE WITH THE FOLLOW ITEMS: | | | | | | COMPLIED. __XX(1)_ CONTRACTOR DID NOT PROVIDE THE MEAN | | | ROOF HEIGHT IN FEET OF BUILDING NOT ADDITION..MEAN ROOF | | | HEIGTH IS TAKEN FROM THE TOP OF THE HIGHRISE NOT THE | | | ADDITION, NEGATIVE PRESSURES ARE TAKEN AT ROOF LEVEL, | | | POSISTIVE PRESSURES BUILD UP FROM GRADE. | | | | | | __XX(2)__ CONTRACTOR FAILED TO INDICATE WHICH SYSTEM TO | | | BE USED. NOTE THERE IS NO PRODUCT APPROVAL SUBMITTED | | | FOR THE FLAT ROOF. | | | | | | _XX(3) ___ THE SYSTEM PROVIDED HAS A LOW PRESSURE FOR | | | ZONE _2&3__ . AGAIN THERE IS NO PRODUCT APPROVAL FOR | | | THE FLAT DECK. | | | | | | _XX__(4) THE SYSTEM PROVIDED STATES LIMITATION# 7, | | | SHOULD THE FASTENER RESISTANCE BE LESS THAN THAT | | | REQUIRED, AS DETERMINED BY THE BUILDING OFFICIAL, A | | | REVISED FASTENER SPACING, PREPARED , SIGNED | | | AND SEALED BY A FLORIDA REGISTERED PROFESSIONAL | | | ENGINEER, REGISTERED ARCHITECT OR REGISTERED ROOF | | | CONSULTANT MAY BE SUBMITTED. | | | | | | MAYBE NO SUBSYSTEM HIGHLIGHTED: | | | _XX__ (5)THE SYSTEM PROVIDED INDICATES LIMITATION# 9, | | | NO ENHANCED FASTENING ALLOWED. | | | | | | 12) ROOFING ASSEMBLIES, METROTILE MANUFACTURING WHICH | | | SYSTEM NOT IDENTIFIED, NOR TYPE OF FASTENING | | | SYSTEM.1609.6.2.2 COMPONENTS AND CLADDING. | | | | | | 13) PROVISO: 109.3.10* IMPACT OF CONSTRUCTION. ALL | | | CONSTRUCTION ACTIVITY REGULATED BY THIS CODE SHALL BE | | | PERFORMED IN A MANNER SO AS NOT TO ADVERSELY IMPACT THE | | | CONDITION OF ADJACENT PROPERTY, UNLESS SUCH ACTIVITY IS | | | PERMITTED TO AFFECT SAID PROPERTY PURSUANT TO A CONSENT | | | BY THE APPLICABLE PROPERTY OWNER, UNDER TERMS & | | | CONDITIONS AGREEABLE TO THE APPLICABLE PROPERTY OWNER. | | | THIS INCLUDES BUT IS NOT LIMITED TO THE CONTROL OF | | | DUST, NOISE, WATER OR DRAINAGE RUN-OFF, DEBRIS, AND THE | | | STORAGE OF CONSTRUCTION MATERIALS. NEW CONSTRUCTION | | | ACTIVITY SHALL NOT ADVERSELY IMPACT HISTORIC SURFACE | | | WATER DRAINAGE FLOWS SERVING ADJACENT PROPERTIES, & MAY | | | REQUIRE SPECIAL DRAINAGE DESIGN COMPLYING WITH | | | ENGINEERING STANDARDS TO PRESERVE THE | | | POSITIVE PATTERNS OF THE AFFECTED SITES. ACCORDINGLY, | | | DEVELOPERS, CONTRACTORS, AND OWNERS OF ALL NEW | | | RESIDENTIAL DEVELOPMENT, INCLUDING ADDITIONS, POOLS, | | | PATIOS, DRIVEWAYS, DECKS, OR SIMILAR ITEMS, ON EXISTING | | | PROPERTIES RESULTING IN A DECREASE IN EXCESS OF 800SQ | | | FT OF PERMEABLE LAND AREA ON ANY PARCEL SHALL AS A | | | PERMIT CONDITION, PROVIDE A PROFESSIONALLY PREPARED | | | DRAINAGE PLAN CLEARLY INDICATING COMPLIANCE WITH THIS | | | PARAGRAPH. UPON COMPLETION OF THE IMPROVEMENT, A | | | CERTIFICATION FROM A LICENSED ENGINEER SHALL BE | | | SUBMITTED TO THE INSPECTOR IN ORDER TO RECEIVE APPROVAL | | | OF THE FINAL INSPECTION. | | | | | | 14) PROVISO: 109.3.10.1 HURRICANE PROTECTION. IT SHALL | | | BE UNLAWFUL FOR ANY PERSON TO ALLOW CONSTRUCTION | | | RELATED MATERIALS EQUIPMENT AND DEBRIS TO REMAIN LOOSE | | | OR OTHERWISE UNSECURED AT A CONSTRUCTION SITE FROM 24 | | | HRS. AFTER A HURRICANE WATCH HAS BEEN ISSUED UNTIL THE | | | HURRICANE WATCH OR WARNING HAS BEEN LIFTED. ALL SUCH | | | CONSTRUCTION MATERIALS, EQUIPMENT AND DEBRIS SHALL BE | | | EITHER REMOVED FROM THE CONSTRUCTION SITE OR SECURED IN | | | SUCH A MANNER AS TO MINIMIZE THE DANGER OF SUCH | | | CONSTRUCTION MATERIALS, EQUIPMENT AND DEBRIS CAUSING | | | DAMAGE TO PERSONS OR PROPERTY FROM HIGH WINDS. ANY | | | PERSONS WHO FAILS TO COMPLY TO REMOVE OR SECURE THE | | | CONSTRUCTION MATERIALS EQUIPMENT AND DEBRIS WITHIN 24 | | | HRS AFTER A HURRICANE WATCH HAS BEEN ISSUED SHALL BE | | | SUBJECT TO A FINE NOT TO EXCEED $500.00. IN ADDITION TO | | | THE ABOVE, A LICENSED CONTRACTOR WHO VIOLATES THIS | | | SECTION SHALL BE SUBJECT TO DISCIPLINE PURSUANT TO | | | SECTION 113 OF THIS CHAPTER. | | | | | | 15) 3RD REQUEST, BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY. | | | THE ACTUAL PERMIT SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT ATTACHED TO THE | | | PERMIT APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A | | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | | THIS REVIEW. | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2008-11-04 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-11-04 |
Time |
16:31 |
Rev Time |
1.55 |
| Received By |
jwitmer |
Date |
2008-11-04 |
Time |
16:31 |
Sent To |
|
|
| Notes |
| 2008-11-04 16:57:30 | BUILDING PLAN REVIEW | | | PERMIT: 08080664 | | | ADD: 1801 N FLAGLER DR | | | CONT: SEACREST SERVICES | | | TEL: (561)346-8449 | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | NOV.04/2008 | | | 2ND REVIEW | | | ACTION: DENIED | | | | | | 1A) INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE | | | INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | 1B) 2ND REQUEST, PLEASE SUBMIT 3 OF ALL SURVEYS, PLANS, | | | REPORTS, REVISIONS , PRODUCT APPROVALS AND OR | | | SUBMITTALS FOR REVIEW FOR PERMIT. YOUR PROJECT WILL | | | REQUIRE A THRESHOLD BUILDING REQUIRING A THRESHOLD | | | INSPECTOR THEN (3) THREE SETS OF ALL SAID DOCUMENTS | | | WILL BE REQUIRED FOR PERMIT ISSUANCE. 106.1* /2004 | | | SUBMITTAL DOCUMENTS WEST PALM BEACH ADMINISTRATIVE | | | CODE. | | | | | | 1C) COMPLIED. | | | | | | 1D)2ND REQUEST, PLANS SUBMITTED FOR PERMIT (FIRST TIME | | | REVIEW) AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO THE | | | 2004 FBC BUILDING WITH THE 2007 SUPPLEMENTS.SHEET S-2 | | | NEEDS UP DATING TO THE 2007 SUPPLEMENTS. | | | | | | 1E) 2ND REQUEST, PLANS FAIL TO INDICATE DESIGNED TO THE | | | 2004 EXISTING BUILDING CODE, CHAPTER 9 ADDITIONS. | | | | | | 2) ) 110.2* W. P. B. ADMINISTRATIVE CODE, INFORMATION | | | THAT IS REQUIRED FOR RECORD KEEPING & FOR CERTIFICATE | | | OF OCCUPANCY: | | | A) THE EDITION OFTHE CODE UNDER WHICH THE PROJECT IS | | | DESIGNED. | | | | | | B) COMPLIED. | | | | | | C) 2ND REQUEST, THE TYPE OF CONSTRUCTION AS DEFINED IN | | | TABLE 503, CHAPTER 6 & TABLE 601.SHEET S-2 INDICATES | | | THIS IS AN ADDITION TO A HIGH RISE. PLEASE REVIEW | | | EXISTING BUILDING CODE 901.2 AN ADDITION SHALL NOT | | | CREATE OR EXTEND A NONCONFORMITY. BY TRYING TO CLASSIFY | | | THE ADDITION AS A TYPE V-B BUILDING YOU ARE ALSO | | | DECLARING THE HIGHRISE AS A TYPE V-B BUILDING. THE | | | HIGHRISE IS CONSIDERED EITHER A TYPE I-A OR I-B | | | DEPENDING ON THE HEIGTH OF THE BUILDING SEE TABLE 503. | | | IF THE ADDITION DID NOT COMMUNICATE WITH THE HIGHRISE | | | NO DOOR LEADING INTO THE HIGHRISE AND WAS ACTUALLY TWO | | | SEPERATE BUILDINGS WE WOULD STILL HAVE TO CONSIDER THE | | | CLOSENESS OF THE TWO BUILDINGS SEE TABLE 602 FOR WALL | | | RATINGS. | | | | | | D) IF AN AUTOMATIC SPRINKLER SYSTEM IS PROVIDED WITHIN | | | THE HIGHRISE? AREA INCREASES MAY OF BEEN TAKEN FOR THE | | | HIGHRISE, EXISTING BUILDING CODE, 902.2 | | | | | | E) WHETHER THE SPRINKLER SYSTEM IS REQUIRED. | | | | | | G) ANY SPECIAL STIPULATIONS & CONDITIONS OF THE | | | BUILDING PERMIT | | | . | | | H) NUMBER OF FLOORS FOR THE HIGHRISE THIS WILL ACTUALLY | | | PROVIDE TTHE BUILDING TYPE CLASSIFICATION TABLE 503FBC, | | | BUILDING .902.1 EXISTING BUILDING CODE. | | | | | | I ) SQ. FT. FOOTPRINT OF EXISTING BUILDING, TABLE 503 | | | FBC, BUILDING & 902.2 EXISTING BUILDING CODE. | | | | | | 3) THIS BUILDING IS A 9 STORY BUILDING OR CONSIDERED A | | | THRESHOLD BUILDING REQUIRING : | | | FL S. S. 553.71(7) " THRESHOLD BUILDING" MEANING ANY | | | BUILDING WHICH IS GREATER THAN (3) STORIES OR 50 FT IN | | | HEIGHT, OR WHICH HAS AN ASSEMBLY OCCUPANCY | | | CLASSIFICATION AS DENIED IN THE | | | FLORIDA BUILDING CODE WHICH EXCEEDS 5,000 SQ FT IN AREA | | | AND AN OCCUPANT CONTENT OF GREATER THAN 500 PERSONS. | | | | | | 3A) 2ND REQUEST, THRESHOLD INSPECTION PLAN 105.13.1 THE | | | ENFORCING AGENCY SHALL REQUIRE A SPECIAL INSPECTOR TO | | | PERFORM STRUCTURAL INSPECTIONS ON A THRESHOLD BUILDING | | | PURSUANT TO A STRUCTURAL INSPECTION PLAN PREPARED BY | | | THE ENGINEER OF RECORD. THE STRUCTURAL INSPECTION PLAN | | | MUST BE SUBMITTED TO THE ENFORCING AGENCY PRIOR TO THE | | | ISSUANCE OF A BUILDING PERMIT FOR THE CONSTRUCTION OF A | | | THRESHOLD BUILDING. THE PURPOSE OF THE STRUCTURAL | | | INSPECTION PLAN IS TO PROVIDE SPECIFIC INSPECTION | | | PROCEDURES AND SCHEDULES SO THAT THE BUILDING CAN BE | | | ADEQUATELY INSPECTED FOR COMPLIANCE WITH THE PERMITTED | | | DOCUMENTS. | | | | | | 3B)2ND REQUEST, THRESHOLD INSPECTOR: WPB AMENDMENT | | | 105.13.6. W.P.B. CONSTRUCTION SERVICES DEPARTMENT | | | REQUEST FOR THRESHOLD BUILDINGS A SPECIAL INSPECTOR AS | | | REQUIRED BY FL S S 553.79(5) FLORIDA STATUTES TO THE | | | MINIMUM INSPECTIONS REQUIRED BY THIS CODE. CONTACT KEN | | | CONRAD MANAGER OF THE SPECIAL INSPECTOR PROGRAM AT | | | (561)805-6666 FOR FURTHER INFORMATION BEFORE THE PERMIT | | | MAY BE ISSUED. | | | | | | 3C) 2ND REQUEST, THRESHOLD BLDG, REQUIRED STATEMENT: | | | W.P.B. AMENDMENT 105.13.4.4 ALL PLANS FOR THE BUILDING | | | WHICH ARE REQUIRED TO BE SIGNED AND SEALED BY THE | | | ARCHITECT OR ENGINEER OF RECORD CONTAIN A STATEMENT | | | THAT, TO THE BEST OF THE ARCHITECT'S PR ENGINEER'S | | | KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE | | | APPLICABLE FIRE-SAFETY STANDARDS AS DETERMINED BY THE | | | LOCAL AUTHORITY IN ACCORDANCE WITH THIS SECTION AND 633 | | | FLORIDA STATUTE. | | | | | | 4) BUILDING PROVISO: FBC BUILDING 3110.1.2 / CITY OF | | | WPB CODE OF ORDINANCES SECTION 94-546. STRUCTURE IS | | | LOCATED IN AN "A-5" FLOOD ZONE. A FLOOD ELEVATION | | | CERTIFICATE WILL BE REQUIRED BEFORE A CERTIFICATE OF | | | COMPLETION WILL BE AWARDED.. PLEASE INDICATE THE | | | ELEVATION OF THE FLOOR SLAB. THE MINIMUM SLAB ELEVATION | | | IS 7'-6". | | | | | | 5) PLEASE PROVIDE 3 ORIGINAL SIGNED & SEALED SOILS | | | REPORTS. 1802.2.1 QUESTIONABLE SOIL. WHERE THE | | | SAFE-SUSTAINING POWER OF THE SOIL IS IN DOUBT, OR WHERE | | | A LOAD-BEARING VALUE SUPERIOR TO THAT SPECIFIED IN THIS | | | CODE IS CLAIMED, THE BUILDING OFFICIAL SHALL REQUIRE | | | THAT THE NECESSARY INVESTIGATION BE MADE. SUCH | | | INVESTIGATION SHALL COMPLY WITH THE PROVISIONS OF | | | SECTIONS 1802.4 THROUGH 1802.6 . | | | | | | 6) COMPLIED. | | | | | | | | | 7) 2ND REQUEST,THIS BUILDING TYPE WILL BE A MINIMUM OF | | | TYPE IB PLEASE REVIEW COMBUSTIBLE/ NONCOMBUSTIBLES | | | MATERIALS ALLOWED IN 603.1 FBC. WALL ASSEMBLIES ROOF | | | FRAMING AND ROOF DECKS. | | | | | | 8) COMPLIED. | | | | | | 9) 2ND REQUEST, 106.3* PRODUCT APPROVALS. THOSE PRODUCT | | | WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE REVIEWED | | | AND APPROVED "IN WRITING" BY THE DESIGNER OF RECORD | | | PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | | | | 10) SHEET S-1 ROOF FRAMING PLANS INDICATES THE USE OF | | | 2X10'S BUT THERE IS NO INFORMATION AS TO HOW THEY WILL | | | ATTACH TO THE EXISTING BUILDING, LEDGERS, BUCKETS ETC? | | | 106.1.2 ADDITIONAL INFORMATION REQUIRED. | | | | | | 11) FLAT ROOF REVIEW: THIS ROOF IS MISSING OR NOT IN | | | COMPLIANCE WITH THE FOLLOW ITEMS: | | | | | | __XX_ CONTRACTOR DID NOT PROVIDE THE MEAN ROOF HEIGHT | | | IN FEET OF BUILDING NOT ADDITION..MEAN ROOF HEIGTH IS | | | TAKEN FROM THE TOP OF THE HIGHRISE NOT THE ADDITION, | | | NEGATIVE PRESSURES ARE TAKEN AT ROOF LEVEL, POSISTIVE | | | PRESSURES BUILD UP FROM GRADE. | | | | | | __XX__ CONTRACTOR FAILED TO INDICATE WHICH SYSTEM TO BE | | | USED. | | | | | | _XX___ THE SYSTEM PROVIDED HAS A LOW PRESSURE FOR ZONE | | | _2&3__ . | | | | | | _XX__ THE SYSTEM PROVIDED STATES LIMITATION# 7, SHOULD | | | THE FASTENER RESISTANCE BE LESS THAN THAT REQUIRED, AS | | | DETERMINED BY THE BUILDING OFFICIAL, A REVISED FASTENER | | | SPACING, PREPARED , SIGNED | | | AND SEALED BY A FLORIDA REGISTERED PROFESSIONAL | | | ENGINEER, REGISTERED ARCHITECT OR REGISTERED ROOF | | | CONSULTANT MAY BE SUBMITTED. | | | | | | MAYBE NO SUBSYSTEM HIGHLIGHTED: | | | _XX__ THE SYSTEM PROVIDED INDICATES LIMITATION# 9, NO | | | ENHANCED FASTENING ALLOWED. | | | | | | 12) ROOFING ASSEMBLIES, METROTILE MANUFACTURING WHICH | | | SYSTEM NOT IDENTIFIED, NOR TYPE OF FASTENING | | | SYSTEM.1609.6.2.2 COMPONENTS AND CLADDING. | | | | | | 13) PROVISO: 109.3.10* IMPACT OF CONSTRUCTION. ALL | | | CONSTRUCTION ACTIVITY REGULATED BY THIS CODE SHALL BE | | | PERFORMED IN A MANNER SO AS NOT TO ADVERSELY IMPACT THE | | | CONDITION OF ADJACENT PROPERTY, UNLESS SUCH ACTIVITY IS | | | PERMITTED TO AFFECT SAID PROPERTY PURSUANT TO A CONSENT | | | BY THE APPLICABLE PROPERTY OWNER, UNDER TERMS & | | | CONDITIONS AGREEABLE TO THE APPLICABLE PROPERTY OWNER. | | | THIS INCLUDES BUT IS NOT LIMITED TO THE CONTROL OF | | | DUST, NOISE, WATER OR DRAINAGE RUN-OFF, DEBRIS, AND THE | | | STORAGE OF CONSTRUCTION MATERIALS. NEW CONSTRUCTION | | | ACTIVITY SHALL NOT ADVERSELY IMPACT HISTORIC SURFACE | | | WATER DRAINAGE FLOWS SERVING ADJACENT PROPERTIES, & MAY | | | REQUIRE SPECIAL DRAINAGE DESIGN COMPLYING WITH | | | ENGINEERING STANDARDS TO PRESERVE THE | | | POSITIVE PATTERNS OF THE AFFECTED SITES. ACCORDINGLY, | | | DEVELOPERS, CONTRACTORS, AND OWNERS OF ALL NEW | | | RESIDENTIAL DEVELOPMENT, INCLUDING ADDITIONS, POOLS, | | | PATIOS, DRIVEWAYS, DECKS, OR SIMILAR ITEMS, ON EXISTING | | | PROPERTIES RESULTING IN A DECREASE IN EXCESS OF 800SQ | | | FT OF PERMEABLE LAND AREA ON ANY PARCEL SHALL AS A | | | PERMIT CONDITION, PROVIDE A PROFESSIONALLY PREPARED | | | DRAINAGE PLAN CLEARLY INDICATING COMPLIANCE WITH THIS | | | PARAGRAPH. UPON COMPLETION OF THE IMPROVEMENT, A | | | CERTIFICATION FROM A LICENSED ENGINEER SHALL BE | | | SUBMITTED TO THE INSPECTOR IN ORDER TO RECEIVE APPROVAL | | | OF THE FINAL INSPECTION. | | | | | | 14) PROVISO: 109.3.10.1 HURRICANE PROTECTION. IT SHALL | | | BE UNLAWFUL FOR ANY PERSON TO ALLOW CONSTRUCTION | | | RELATED MATERIALS EQUIPMENT AND DEBRIS TO REMAIN LOOSE | | | OR OTHERWISE UNSECURED AT A CONSTRUCTION SITE FROM 24 | | | HRS. AFTER A HURRICANE WATCH HAS BEEN ISSUED UNTIL THE | | | HURRICANE WATCH OR WARNING HAS BEEN LIFTED. ALL SUCH | | | CONSTRUCTION MATERIALS, EQUIPMENT AND DEBRIS SHALL BE | | | EITHER REMOVED FROM THE CONSTRUCTION SITE OR SECURED IN | | | SUCH A MANNER AS TO MINIMIZE THE DANGER OF SUCH | | | CONSTRUCTION MATERIALS, EQUIPMENT AND DEBRIS CAUSING | | | DAMAGE TO PERSONS OR PROPERTY FROM HIGH WINDS. ANY | | | PERSONS WHO FAILS TO COMPLY TO REMOVE OR SECURE THE | | | CONSTRUCTION MATERIALS EQUIPMENT AND DEBRIS WITHIN 24 | | | HRS AFTER A HURRICANE WATCH HAS BEEN ISSUED SHALL BE | | | SUBJECT TO A FINE NOT TO EXCEED $500.00. IN ADDITION TO | | | THE ABOVE, A LICENSED CONTRACTOR WHO VIOLATES THIS | | | SECTION SHALL BE SUBJECT TO DISCIPLINE PURSUANT TO | | | SECTION 113 OF THIS CHAPTER. | | | | | | 15) 2ND REQUEST, BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY. | | | THE ACTUAL PERMIT SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT ATTACHED TO THE | | | PERMIT APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A | | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | | THIS REVIEW. | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-09-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-09-08 |
Time |
11:09 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2008-09-08 |
Time |
11:09 |
Sent To |
|
|
| Notes |
| 2008-09-08 12:04:47 | | | | BUILDING PLAN REVIEW | | | PERMIT: 08080664 | | | ADD: 1801 N FLAGLER DR | | | CONT: SEACREST SERVICES | | | TEL: (561)346-8449 | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | SEPTEMBER 08,2008 | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1A) INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE | | | INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | 1B) INFORMATIONAL: PLEASE SUBMIT 3 OF ALL SURVEYS, | | | PLANS, REPORTS, REVISIONS , PRODUCT APPROVALS AND OR | | | SUBMITTALS FOR REVIEW FOR PERMIT. YOUR PROJECT WILL | | | REQUIRE A THRESHOLD BUILDING REQUIRING A THRESHOLD | | | INSPECTOR THEN (3) THREE SETS OF ALL SAID DOCUMENTS | | | WILL BE REQUIRED FOR PERMIT ISSUANCE. 106.1* /2004 | | | SUBMITTAL DOCUMENTS WEST PALM BEACH ADMINISTRATIVE | | | CODE. | | | | | | 1C) INFORMATIONAL FL S S 713.13 NOTICE OF COMMENCEMENT, | | | TO BE FILED WITH THE CLERK OF THE COURT. NOTE: | | | 713.13(2) IF THE WORK DESCRIBED IN THE NOTICE OF | | | COMMENCEMENT IS NOT ACTUALLY COMMENCED WITHIN 90 DAYS | | | AFTER THE RECORDING THEREOF, SUCH NOTICE IS NULL & | | | VOID. NOTE: 713.13(6) THE POSTING OF THE NOTICE OF | | | COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE THE FIRST | | | INSPECTION. | | | | | | 1D) INFORMATIONAL: PLANS SUBMITTED FOR PERMIT (FIRST | | | TIME REVIEW) AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO | | | THE 2004 FBC BUILDING WITH THE 2007 SUPPLEMENTS. | | | | | | 1E) PLANS FAIL TO INDICATE DESIGNED TO THE 2004 | | | EXISTING BUILDING CODE, CHAPTER 9 ADDITIONS. | | | | | | 2) ) 110.2* W. P. B. ADMINISTRATIVE CODE, INFORMATION | | | THAT IS REQUIRED FOR RECORD KEEPING & FOR CERTIFICATE | | | OF OCCUPANCY: | | | A) THE EDITION OFTHE CODE UNDER WHICH THE PROJECT IS | | | DESIGNED. | | | | | | B) THE USE AND OCCUPANCY, IN ACCORDANCE WITH THE | | | PROVISIONS OF CHAPTER 3. | | | | | | C) THE TYPE OF CONSTRUCTION AS DEFINED IN CHAPTER 6, | | | TABLE 601. | | | | | | D) IF AN AUTOMATIC SPRINKLER SYSTEM IS PROVIDED | | | | | | E) WHETHER THE SPRINKLER SYSTEM IS REQUIRED. | | | | | | G) ANY SPECIAL STIPULATIONS & CONDITIONS OF THE | | | BUILDING PERMIT | | | . | | | H) NUMBER OF FLOORS | | | | | | I ) SQ. FT. FOOTPRINT OF EXISTING BUILDING | | | | | | 3) THIS BUILDING IS A 9 STORY BUILDING OR CONSIDERED A | | | THRESHOLD BUILDING REQUIRING : | | | FL S. S. 553.71(7) " THRESHOLD BUILDING" MEANING ANY | | | BUILDING WHICH IS GREATER THAN (3) STORIES OR 50 FT IN | | | HEIGHT, OR WHICH HAS AN ASSEMBLY OCCUPANCY | | | CLASSIFICATION AS DENIED IN THE | | | FLORIDA BUILDING CODE WHICH EXCEEDS 5,000 SQ FT IN AREA | | | AND AN OCCUPANT CONTENT OF GREATER THAN 500 PERSONS. | | | | | | 3A) THRESHOLD INSPECTION PLAN 105.13.1 THE ENFORCING | | | AGENCY SHALL REQUIRE A SPECIAL INSPECTOR TO PERFORM | | | STRUCTURAL INSPECTIONS ON A THRESHOLD BUILDING PURSUANT | | | TO A STRUCTURAL INSPECTION PLAN PREPARED BY THE | | | ENGINEER OF RECORD. THE STRUCTURAL INSPECTION PLAN MUST | | | BE SUBMITTED TO THE ENFORCING AGENCY PRIOR TO THE | | | ISSUANCE OF A BUILDING PERMIT FOR THE CONSTRUCTION OF A | | | THRESHOLD BUILDING. THE PURPOSE OF THE STRUCTURAL | | | INSPECTION PLAN IS TO PROVIDE SPECIFIC INSPECTION | | | PROCEDURES AND SCHEDULES SO THAT THE BUILDING CAN BE | | | ADEQUATELY INSPECTED FOR COMPLIANCE WITH THE PERMITTED | | | DOCUMENTS. | | | | | | 3B) THRESHOLD INSPECTOR: WPB AMENDMENT 105.13.6. W.P.B. | | | CONSTRUCTION SERVICES DEPARTMENT REQUEST FOR THRESHOLD | | | BUILDINGS A SPECIAL INSPECTOR AS REQUIRED BY FL S S | | | 553.79(5) FLORIDA STATUTES TO THE MINIMUM INSPECTIONS | | | REQUIRED BY THIS CODE. CONTACT KEN CONRAD MANAGER OF | | | THE SPECIAL INSPECTOR PROGRAM AT (561)805-6666 FOR | | | FURTHER INFORMATION BEFORE THE PERMIT MAY BE ISSUED. | | | | | | 3C) THRESHOLD BLDG, REQUIRED STATEMENT: W.P.B. | | | AMENDMENT 105.13.4.4 ALL PLANS FOR THE BUILDING WHICH | | | ARE REQUIRED TO BE SIGNED AND SEALED BY THE | | | ARCHITECT OR ENGINEER OF RECORD CONTAIN A STATEMENT | | | THAT, TO THE BEST OF THE ARCHITECT'S PR ENGINEER'S | | | KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE | | | APPLICABLE FIRE-SAFETY STANDARDS AS DETERMINED BY THE | | | LOCAL AUTHORITY IN ACCORDANCE WITH THIS SECTION AND 633 | | | FLORIDA STATUTE. | | | | | | 4) FBC BUILDING 3110.1.2 / CITY OF WPB CODE OF | | | ORDINANCES SECTION 94-546. STRUCTURE IS LOCATED IN AN | | | "A-5" FLOOD ZONE. A FLOOD ELEVATION CERTIFICATE WILL BE | | | REQUIRED BEFORE A CERTIFICATE OF COMPLETION WILL BE | | | AWARDED.. PLEASE INDICATE THE ELEVATION OF THE FLOOR | | | SLAB. THE MINIMUM SLAB ELEVATION IS 7'-6". | | | | | | 5) PLEASE PROVIDE 3 ORIGINAL SIGNED & SEALED SOILS | | | REPORTS. 1802.2.1 QUESTIONABLE SOIL. WHERE THE | | | SAFE-SUSTAINING POWER OF THE SOIL IS IN DOUBT, OR WHERE | | | A LOAD-BEARING VALUE SUPERIOR TO THAT SPECIFIED IN THIS | | | CODE IS CLAIMED, THE BUILDING OFFICIAL SHALL REQUIRE | | | THAT THE NECESSARY INVESTIGATION BE MADE. SUCH | | | INVESTIGATION SHALL COMPLY WITH THE PROVISIONS OF | | | SECTIONS 1802.4 THROUGH 1802.6 . | | | | | | 6) THE PARTIAL SITE PLAN INDICATES THAT THE NEW | | | ADDITION HAS A CLEAR UNOBSTRUCTED PATH TO THE EAST FOR | | | MORE THAN 600 FEET. THIS WILL MAKE IT LOCATED WITH A | | | "C" ZONE NOT THE "B" ZONE LISTED LISTED ON SHEET | | | S-2. ALSO NOTE THE NEGATIVE PRESSURES ARE TAKEN FROM | | | THE BUILDINGS HIGHEST POINT SO THE NEGATIVE PRESSURES | | | WILL ALSO BE MUCH HIGHER . THIS BUILDING IS ALSO OVER | | | 60 FEET IN HEIGHT REQUIREING THE | | | PRESSURES TO BE TAKEN FROM ASCE 7-02 SECTION 6. PLEASE | | | SEE 2004 FBC 2007 SUPPLEMENTS 1609.4 SEE CATEGORY "C" | | | TYPE TERRAIN. 1609.1.1. | | | | | | | | | | | | 7) THIS BUILDING TYPE WILL BE A MINIMUM OF TYPE IB | | | PLEASE REVIEW COMBUSTIBLE/ NONCOMBUSTIBLES MATERIALS | | | ALLOWED IN 603.1 FBC. WALL ASSEMBLIES ROOF FRAMING AND | | | ROOF DECKS. | | | | | | 8) PLANS DO NOT PROVIDE IF THIS ADDITION WILL HAVE A/C? | | | PLEASE PROVIDE COMPLIANCE WITH CHAPTER 13 OF THE FBC. | | | 13-101.1.2. | | | | | | 9) 106.3* PRODUCT APPROVALS. THOSE PRODUCT WHICH ARE | | | REGULATED BY DCA RULE 9B-72 SHALL BE REVIEWED AND | | | APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO | | | SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | | | | 10) SHEET S-1 ROOF FRAMING PLANS INDICATES THE USE OF | | | 2X10'S BUT THERE IS NO INFORMATION AS TO HOW THEY WILL | | | ATTACH TO THE EXISTING BUILDING, LEDGERS, BUCKETS ETC? | | | 106.1.2 ADDITIONAL INFORMATION REQUIRED. | | | | | | 11) FLAT ROOF REVIEW: THIS ROOF IS MISSING OR NOT IN | | | COMPLIANCE WITH THE FOLLOW ITEMS: | | | | | | __XX_ CONTRACTOR DID NOT PROVIDE THE MEAN ROOF HEIGHT | | | IN FEET OF BUILDING NOT ADDITION.. | | | | | | __XX__ CONTRACTOR FAILED TO INDICATE WHICH SYSTEM TO BE | | | USED. | | | | | | _XX___ THE SYSTEM PROVIDED HAS A LOW PRESSURE FOR ZONE | | | _2&3__ . | | | | | | _XX__ THE SYSTEM PROVIDED STATES LIMITATION# 7, SHOULD | | | THE FASTENER RESISTANCE BE LESS THAN THAT REQUIRED, AS | | | DETERMINED BY THE BUILDING OFFICIAL, A REVISED FASTENER | | | SPACING, PREPARED , SIGNED | | | AND SEALED BY A FLORIDA REGISTERED PROFESSIONAL | | | ENGINEER, REGISTERED ARCHITECT OR REGISTERED ROOF | | | CONSULTANT MAY BE SUBMITTED. | | | | | | MAYBE NO SUBSYSTEM HIGHLIGHTED: | | | _XX__ THE SYSTEM PROVIDED INDICATES LIMITATION# 9, NO | | | ENHANCED FASTENING ALLOWED. | | | | | | 12) UNKNOWNS METROTILE MANUFACTURING WHICH SYSTEM NOT | | | IDENTIFIED, NOR TYPE OF FASTENING SYSTEM. | | | | | | 13) PROVISO: 109.3.10* IMPACT OF CONSTRUCTION. ALL | | | CONSTRUCTION ACTIVITY REGULATED BY THIS CODE SHALL BE | | | PERFORMED IN A MANNER SO AS NOT TO ADVERSELY IMPACT THE | | | CONDITION OF ADJACENT PROPERTY, UNLESS SUCH ACTIVITY IS | | | PERMITTED TO AFFECT SAID PROPERTY PURSUANT TO A CONSENT | | | BY THE APPLICABLE PROPERTY OWNER, UNDER TERMS & | | | CONDITIONS AGREEABLE TO THE APPLICABLE PROPERTY OWNER. | | | THIS INCLUDES BUT IS NOT LIMITED TO THE CONTROL OF | | | DUST, NOISE, WATER OR DRAINAGE RUN-OFF, DEBRIS, AND THE | | | STORAGE OF CONSTRUCTION MATERIALS. NEW CONSTRUCTION | | | ACTIVITY SHALL NOT ADVERSELY IMPACT HISTORIC SURFACE | | | WATER DRAINAGE FLOWS SERVING ADJACENT PROPERTIES, & MAY | | | REQUIRE SPECIAL DRAINAGE DESIGN COMPLYING WITH | | | ENGINEERING STANDARDS TO PRESERVE THE | | | POSITIVE PATTERNS OF THE AFFECTED SITES. ACCORDINGLY, | | | DEVELOPERS, CONTRACTORS, AND OWNERS OF ALL NEW | | | RESIDENTIAL DEVELOPMENT, INCLUDING ADDITIONS, POOLS, | | | PATIOS, DRIVEWAYS, DECKS, OR SIMILAR ITEMS, ON EXISTING | | | PROPERTIES RESULTING IN A DECREASE IN EXCESS OF 800SQ | | | FT OF PERMEABLE LAND AREA ON ANY PARCEL SHALL AS A | | | PERMIT CONDITION, PROVIDE A PROFESSIONALLY PREPARED | | | DRAINAGE PLAN CLEARLY INDICATING COMPLIANCE WITH THIS | | | PARAGRAPH. UPON COMPLETION OF THE IMPROVEMENT, A | | | CERTIFICATION FROM A LICENSED ENGINEER SHALL BE | | | SUBMITTED TO THE INSPECTOR IN ORDER TO RECEIVE APPROVAL | | | OF THE FINAL INSPECTION. | | | | | | 14) PROVISO: 109.3.10.1 HURRICANE PROTECTION. IT SHALL | | | BE UNLAWFUL FOR ANY PERSON TO ALLOW CONSTRUCTION | | | RELATED MATERIALS EQUIPMENT AND DEBRIS TO REMAIN LOOSE | | | OR OTHERWISE UNSECURED AT A CONSTRUCTION SITE FROM 24 | | | HRS. AFTER A HURRICANE WATCH HAS BEEN ISSUED UNTIL THE | | | HURRICANE WATCH OR WARNING HAS BEEN LIFTED. ALL SUCH | | | CONSTRUCTION MATERIALS, EQUIPMENT AND DEBRIS SHALL BE | | | EITHER REMOVED FROM THE CONSTRUCTION SITE OR SECURED IN | | | SUCH A MANNER AS TO MINIMIZE THE DANGER OF SUCH | | | CONSTRUCTION MATERIALS, EQUIPMENT AND DEBRIS CAUSING | | | DAMAGE TO PERSONS OR PROPERTY FROM HIGH WINDS. ANY | | | PERSONS WHO FAILS TO COMPLY TO REMOVE OR SECURE THE | | | CONSTRUCTION MATERIALS EQUIPMENT AND DEBRIS WITHIN 24 | | | HRS AFTER A HURRICANE WATCH HAS BEEN ISSUED SHALL BE | | | SUBJECT TO A FINE NOT TO EXCEED $500.00. IN ADDITION TO | | | THE ABOVE, A LICENSED CONTRACTOR WHO VIOLATES THIS | | | SECTION SHALL BE SUBJECT TO DISCIPLINE PURSUANT TO | | | SECTION 113 OF THIS CHAPTER. | | | | | | 15) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A | | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | | THIS REVIEW. | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2009-01-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-01-16 |
Time |
14:55 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-01-16 |
Time |
14:55 |
Sent To |
|
|
| Notes |
| 2009-01-16 14:56:05 | ** DENIED PLANS** | | | | | | **THIRD REVIEW** | | | | | | | | | | | | | | | 1) NOTE: THE TITLE BLOCKS ARE STILL MISSING THE | | | REQUIRED LICENSING PER FS 471.023 AND FAC 61G15-23.002. | | | THE CERTIFICATE # AS SHOWN FOR KING STRUCTURAL GROUP IS | | | IN FACT THE PE LICENSE NUMBER. A CERTIFICATE OF | | | AUTHORIZATION NUMBER IS REQUIRED BY STATE STATUTES. | | | THIS HAS BEEN NOTED THREE TIMES WITH NO CORRECTION FOR | | | LICENSING. PLANS MAY BE RETAINED FOR REVIEW FROM THE | | | FLORIDA BOARD OF ENGINEERS LEGAL COUNSEL. | | | | | | 2) NOTE: PLEASE SEE ALL PREVIOUS NOTES. LIGHTING | | | CONTROLS DO NOT COMPLY TO 13-415.1.ABC.1, .1.1, .1.2. | | | A MANUAL SWITCH IS NOT THE ONLY REQUIREMENT. | | | MUST CONTAIN AN AUTOMATIC MEANS OF SHUTTING OFF THE | | | LIGHTING. | | | | | | 3) NOTE: PLEASE SHOW ALL CIRCUITING ON PLANS AND | | | CORRELATE WITH A PANEL SCHEDULE TO BE SUBMITTED AS | | | REQUESTED ON ALL PREVIOUS REVIEWS. THE RESPONSE | | | MENTIONS THE CIRCUITING WAS ADDED HOWEVER THESE ARE | | | BLANK ON PLANS. | | | PLEASE PROVIDE LOADS ON THE EXISTING PANEL WHICH IS | | | BEING NOTED WITH THE NEW LOADS ADDED. | | | THE LOAD ON THE CIRCUIT FOR THE A/C IS SHOWN AT 2500VA | | | WHICH FAR EXCEEDS THE RATING OF A 1-POLE 20AMP BRANCH | | | CIRCUIT. | | | 240.4,310.16,408.4, 220.87, 215.5 ETC | | | | | | 4) NOTE: PLEASE SEE 13-415.2.ABC.1.1, .1.2 AND .1.3. | | | THE RESPONSE MENTIONS THIS *ADDITION CONTAINS A SINGLE | | | INDEPENDENTLY OPERATED LIGHTING SYSTEM* | | | THIS OFFICE DOES NOT KNOW WHAT THIS RESPONSE IS FOR??? | | | THE ABOVE SECTIONS GIVEN SINCE THE BEGINNING OF THE | | | REVIEW PROCESS IS FOR MINIMUM LIGHTING PERFORMANCE | | | CALCULATIONS PER THE SECTIONS ABOVE FROM THE FLORIDA | | | BUILDING CODE. THERE IS NO EXCEPTION FOR INDEPENDENT | | | SYSTEMS WHICH EXEMPTS LIGHTING PERFORMANCE CALCULATIONS | | | AND ENERGY COMPLIANCE WITH FBC CHAPTER 13. | | | | | | 5) NOTE: THE ELECTRICAL SHEET WAS REVISED TO INDICATE | | | CODES HOWEVER THE NFPA-70 DOES NOT SHOW ANY YEAR | | | EDITION. | | | PLANS MAY NOT STATE LATEST EDITION AS THE CODES ARE | | | ALWAYS BEING REVISED. THE CODES ARE BASED ON THE TIME | | | OF PERMIT APPLICATION PER FS 553.73. | | | | | | 6) NOTE: PER NOTICE GIVEN ON PREVIOUS REVIEW A FEE HAS | | | NOW BEEN ASSESSED PER FS 553.80(2)(B) WITH RESPECT TO | | | REPEAT COMMENTS FOR CODE COMPLIANCE. THERE ARE SEVERAL | | | SECTIONS OF CODES WHICH WERE REPEATED. THE AMOUNT OF | | | $672 IS DUE BEFORE THE FOLLOWING RESUB. THE RESUB FEE | | | WILL NOT BE REQUIRED. | | | | | | | | | | | | | | | | | | | | | | | | | | | ** IMPORTANT ** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED | | | INTO TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2008-11-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-11-18 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-11-18 |
Time |
11:49 |
Sent To |
|
|
| Notes |
| 2008-11-18 11:49:45 | | | | | | | | | | ** FAILED 2ND REVIEW ** | | | | | | ** PLEASE SEE THAT MANY NOTES FORM PREVIOUS REVIEW ARE | | | STILL NOT ADDRESSED. | | | | | | | | | 1) NOTE: PLEASE SEE TITLE BLOCKS ARE STILL MISSING | | | REQUIRED LICENSING UNDER FS 471.023, FAC61G15-23.002. | | | PLEASE INCLUDE INFORMATION. PLEASE KNOW WORKING AS A | | | FIRM WITHOUT LICENSING IS REQUIRED TO BE FORWARDED TO | | | BE SENT TO THE FLORIDA BOARD OF ENGINEERS. PLEASE | | | SUPPLY INFORMATION OR THIS OFFICE WILL HAVE NO CHOICE | | | BUT TO FORWARD AS STATED. | | | | | | 2) NOTE: PLEASE INCLUDE ALL REQUIRED CODES FOR MINIMUM | | | DESIGN FOR THIS TRADE REVIEWER AS FOLLOWS. | | | 2004 FBC W/2007 REVISION. | | | 2003 NFPA-101 | | | 2005 NFPA-70 | | | | | | 3) NOTE: PLEASE SUBMIT LIGHTING INFORMATION FOR FBC | | | CHAPTER 13. 13-415.2.ABC.1.1,.1.2, .1.3. | | | PLEASE SEE THAT INFORMATION ABOUT ENERGY CALCULATIONS | | | PER 13-400.3 | | | | | | 4) NOTE: PLEASE COMPLETE CIRCUITING, COMPLETE WIRING | | | METHODS FOR ALL RECEPTACLES, GROUNDING, BONDING, | | | BREAKERS, ETC PANEL SCHEDULE, FEEDERS, LOADS ETC. | | | 408.4,240.4,310.16,220.87,225.31-225.39 | | | | | | 5) NOTE: PLEASE SEE FBC 13-415.1.ABC.1.1,.1.2, .1.3 AND | | | .1.4 FOR REQUIRED MINIMUM LIGHTING CONTROLS. | | | | | | 6) NOTE: PLEASE SEE FS 553.80(2)(B) WITH RESPECT TO | | | REPEAT COMMENTS FOR CODE COMPLIANCE. THIS IS A | | | STATUTORY REQUIREMENT AND ONLY A NOTICE GIVEN AT THIS | | | TIME AS THERE ARE SEVERAL REPEAT COMMENTS FOR CODE | | | COMPLIANCE. | | | | | | | | | **IMPORTANT** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED | | | INTO TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2008-09-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-09-10 |
Time |
14:46 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-09-10 |
Time |
14:46 |
Sent To |
|
|
| Notes |
| 2008-09-10 14:46:53 | | | | | | | | | | | | | ** DENIED ** | | | | | | 1) NOTE: PLEASE SEE FAC 61G15-23.022 FOR MISSING | | | INFORMATION REQUIRED ON TITLE BLOCKS. PLEASE SEE FS | | | 471.023 AS THE CERTIFICATE OF AUTHORIZATION NUMBER AS | | | REQUIRED IS MISSING. | | | | | | 2) NOTE: PLANS ARE REQUIRED TO STATES THE CODES IN | | | AFFECT AT THE TIME OF APPLICATION AND DESIGN. | | | THE FOLLOW SHALL BE STATED ON THE PLANS FOR THIS | | | REVIEWER AT A MINIMUM. | | | 2004 FBC W/2007 REVISIONS. | | | 2005 NFPA-70 | | | | | | 3) NOTE: PLEASE COMPLETE PLANS WITH ALL CIRCUITING, | | | CONDUCTORS, PANEL, LOADS, FEEDS, GROUNDING/BONDING | | | SYSTEM ETC. | | | PLANS ARE NOT COMPLETE AT THIS TIME WITH SEVERAL ITEMS | | | AS REQUIRED PER THE FOLLOWING SECTIONS OF THE NEC. | | | . | | | 250.50, 250.110 ETC GROUNDING/BONDING SYSTEM AND | | | GROUNDING. | | | 408.4, 310.16, 240.4 FOR CONDUCTORS, BREAKERS, PANEL | | | SCHEDULE ETC | | | 215.5,240.4,310.16, 220.87 FOR LOADS, FEEDERS, PANEL | | | ETC | | | | | | | | | ** PLANS STATE CIRCUITS TO EXISTING PANEL HOWEVER HOW | | | CAN THIS PANEL BE EXISTING WHEN THE STRUCTURE HAS NOT | | | BEEN BUILT AT THIS TIME. PLEASE BE SURE TO SECTIONS OF | | | CODE GIVEN ABOVE. | | | ** AS PLANS ARE NOT COMPLETE AT THIS TIME, THERE MAY | | | VERY WELL BE NEW COMMENTS ON THE FOLLOWING REVIEW WHICH | | | CAN NOT BE MADE AT THIS TIME. | | | | | | 4) NOTE: PLEASE SEE FBC 13-413.1.ABC.1.1, .1.2 FOR | | | MINIMUM REQUIRED FOR VOLTAGE DROP. | | | | | | 5) NOTE: PLEASE SEE FBC 13-415.2.ABC.1.1, .1.2 AND .1.3 | | | FOR LIGHTING PERFORMANCE CALCULATIONS. | | | | | | 6) NOTE: PLEASE SEE FBC 13-415.1.ABC.1.4 FOR EXTERIOR | | | LIGHTING ON THIS STRUCTURE. AT THIS TIME THE PLANS DO | | | NOT INDICATE ANY LIGHTING FOR DRIVE UP, GATE AREAS ETC. | | | | | | 7) NOTE: PLEASE SEE FBC 13-415.1.ABC.1.1, .1.2 FOR | | | LIGHTING CONTROLS. | | | | | | | | | | | | | | | | | | | | | ** PLEASE KNOW AS PLANS ARE NOT COMPLETE WITH | | | INFORMATION ABOVE AT THIS TIME, WHEN PLANS COME BACK | | | WITH THE INFORMATION NEW COMMENTS MAY BE PART OF THE | | | REVIEW. | | | | | | **IMPORTANT** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | | TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | | | | | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANOR PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2009-02-10 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2009-02-10 |
Time |
09:48 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2009-02-10 |
Time |
09:48 |
Sent To |
|
|
| Notes |
| 2009-02-10 09:49:31 | PLANS WILL BE STAMPED WHEN RETURNED WITH OTHER REVIEW | | | COMMENT CORRECTIONS. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2008-11-24 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-11-24 |
Time |
16:00 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-11-24 |
Time |
16:00 |
Sent To |
|
|
| Notes |
| 2008-11-24 16:02:27 | ***DENIED*** | | | | | | COMMENTS WERE TAKEN DIRECTLY FROM THE FIRST FIRE | | | REVIEW: | | | | | | 1) LIFE SAFETY SHALL COMPLY WITH NFPA 101, 2003 | | | EDITION. | | | | | | 2) ILLUSTRATE EXISTING DRIVE WIDTH AND OTHER PERTINENT | | | DIMENSIONS AS IT APPLIES TO THE NEW GUARD HOUSE. | | | | | | 3) PROVIDE INFORMATION REGARDING NEW GATE ARMS. IE | | | FAILSAFE MECHANISM IN EVENT OF POWER LOSS, WIDTH OF | | | ARMS, POWER SOURCE ETC. PROVIDE MANUFACTURER | | | SPECIFICATION SHEETS. | | | | | | 4) PLANS ILLUSTRATE A NEW CONCRETE WALK WITH SLOPE. | | | INDICATE LENGTH OF WALK AND DIMENSIONS OF SLOPE. | | | | | | 5) WILL THE GUARD HOUSE BE STAFFED? | | | | | | | | | ALTHOUGH NOT A REQUIREMENT, A RESPONSE LETTER | | | INDICATING HOW AND WHERE ON THE PLANS EACH COMMENT WAS | | | ADDRESSED WOULD HELP TO EXPEDITE THE PLAN REVIEW | | | PROCESS. | | | | | | | | | MIKE WENNERGREN, ASST. FIRE MARSHAL | | | FIRE PLAN REVIEW | | | FIRE PREVENTION (561) 804-4756 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2008-09-26 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-09-26 |
Time |
14:19 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-09-26 |
Time |
14:19 |
Sent To |
|
|
| Notes |
| 2008-09-26 14:36:25 | ***DENIED*** | | | | | | 1) LIFE SAFETY SHALL COMPLY WITH NFPA 101, 2003 | | | EDITION. | | | | | | 2) ILLUSTRATE EXISTING DRIVE WIDTH AND OTHER PERTINENT | | | DIMENSIONS AS IT APPLIES TO THE NEW GUARD HOUSE. | | | | | | 3) PROVIDE INFORMATION REGARDING NEW GATE ARMS. IE | | | FAILSAFE MECHANISM IN EVENT OF POWER LOSS, WIDTH OF | | | ARMS, POWER SOURCE ETC. PROVIDE MANUFACTURER | | | SPECIFICATION SHEETS. | | | | | | 4) PLANS ILLUSTRATE A NEW CONCRETE WALK WITH SLOPE. | | | INDICATE LENGTH OF WALK AND DIMENSIONS OF SLOPE. | | | | | | 5) WILL THE GUARD HOUSE BE STAFFED? | | | | | | | | | MIKE WENNERGREN, ASST. FIRE MARSHAL | | | FIRE PLAN REVIEW | | | FIRE PREVENTION (561) 804-4756 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2009-01-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-01-13 |
Time |
10:45 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-01-13 |
Time |
10:45 |
Sent To |
|
|
| Notes |
| 2009-01-13 10:48:26 | TO "COMM" BD#45 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-11-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-11-04 |
Time |
09:32 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-11-04 |
Time |
09:32 |
Sent To |
|
|
| Notes |
| 2008-11-04 09:35:19 | TO "COMM" BD#9 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-09-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-09-29 |
Time |
09:46 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-09-02 |
Time |
13:08 |
Sent To |
|
|
| Notes |
| 2008-09-02 13:13:17 | TO "COMM" BD#16 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2009-02-21 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-02-21 |
Time |
15:16 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-02-21 |
Time |
15:14 |
Sent To |
PC |
|
| Notes |
| 2009-02-21 15:16:37 | MECHANICAL REVIEW IS PASSED. HOWEVER, SINCE THE WORK | | | SCOPE FOR MULTIPLE DISCIPLINES ARE SHOWN ON EACH | | | CSHEET, MECHANICAL PLANS WILL BE STAMPED UPUN PASSED | | | REVIEWS BY BUILDING AND ELECTRICAL TRADES. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2008-11-22 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-11-22 |
Time |
13:15 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-11-22 |
Time |
12:47 |
Sent To |
|
|
| Notes |
| 2008-11-22 13:15:09 | | | | | | | REVIEW #: 2ND | | | ACTION: DENIED | | | | | | FBC 2004 CODE FAMILY W/ 2007 SUPPLEMENTS | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | THE FOLLOWING COMMENTS ARE NUMBERED TO CORRESPOND WITH | | | PREVIOUS REVIEW COMMENTS AS WELL AS DESIGNER'S WRITTEN | | | RESPONSES FOR THE PURPOSE OF CONTINUITY. | | | | | | 1. MINI-SPLIT OK. HOWEVER, THE FOLLOWING ITEMS SHALL BE | | | ADDRESSED AS A RESULT OF THE ADDITION OF THE MINI-SPLIT | | | SYSTEM FROM PREVIOUS PLANS: | | | | | | A) PLEASE SHOW ON PLANS THE MEANS AND LOCATION OF | | | CONDENSATE DISPOSAL. CONDENSATE FROM ALL COOLING COILS | | | SHALL BE CONVEYED FROM THE DRAIN PAN OUTLET TO AN | | | APPROVED PLACE OF DISPOSAL. CONDENSATE SHALL NOT | | | DISCHARGE INTO A STREET, ALLEY OR OTHER AREAS SO AS TO | | | CAUSE A NUISANCE IN ACCORDANCE WITH FBCM 307.2.1. | | | CONDENSATE SHALL NOT DISCHARGE INTO A SANITARY SEWER | | | SYSTEM PER CITY ORDINANCE. | | | | | | B) PROVIDE WIND RESISTANCE INFORMATION FOR THE OUTDOOR | | | CONDENSING UNIT. MECHANICAL APPLIANCES AND SUPPORTS | | | THAT ARE EXPOSED TO WIND SHALL BE DESIGNED AND | | | INSTALLED TO RESIST THE WIND PRESSURES ON THE EQUIPMENT | | | AND THE SUPPORTS AS DETERMINED IN ACCORDANCE WITH FBCM | | | 301.13. SHOW HOW THE APPLIANCE IS TO BE SECURED TO | | | RESIST WIND PRESSURES AND PROVIDE MANUFACTURER'S DATA | | | SHOWING THE APPLIANCE IS DESIGNED TO RESIST WIND | | | PRESSURES IN ACCORDANCE WITH THIS SECTION. | | | | | | C) THERE ARE NO PROVISIONS ON ELECTRICAL PLANS TO | | | PROVIDE POWER FOR THE INDOOR OR OUTDOOR PORTIONS OF | | | THIS SYSTEM. PLEASE CLARIFY IN ACCORDANCE WITH FBCM | | | 304.1. | | | | | | 2. **NOT ADDRESSED** SHOW HOW THE REQUIRED RATE OF | | | VENTILATION IS TO BE PROVIDED IN ACCORDANCE WOTH FBCM | | | 403. | | | | | | 3. **NOT ADDRESSED** THE ENGINEERING BUSINESS | | | CERTIFICATE OF AUTHORIZATION NUMBER SHALL APPEAR IN THE | | | TITLE BLOCK IN ACCORDANCE WITH FAC RULE 61G15-23.002. | | | **THERE IS STILL NO CERTIFICATE OF AUTHORIZATION NUMBER | | | IN THEE ENGINEERING BUSINESS TITLE BLOCK. PLEASE SEE | | | FAC RULE 61G15-23.002 FOR ENGINEERING BUSINESS TITLE | | | BLOCK REQUIREMENTS IN ACCORDANCE WITH F.S. 471. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2008-09-09 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-09-09 |
Time |
11:14 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-09-09 |
Time |
10:58 |
Sent To |
|
|
| Notes |
| 2008-09-09 11:14:19 | REVIEW #: 1ST | | | ACTION: DENIED | | | | | | FBC 2004 CODE FAMILY W/ 2007 SUPPLEMENTS | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | 1. MECHANICAL NOTES CALL FOR NEW SUPPLY DUCT FROM | | | EXISTING SYSTEM. THERE ARE NO PROVISIONS FOR RETURN AIR | | | FROM THIS SPACE. SHOW HOW BALANCED RETURN IS TO BE | | | ACHIEVED IN ACCORDANCE WITH FBCM 601.4. | | | | | | 2. SHOW HOW THE REQUIRED RATE OF VENTILATION IS TO BE | | | PROVIDED IN ACCORDANCE WOTH FBCM 403. | | | | | | 3. THE ENGINEERING BUSINESS CERTIFICATE OF | | | AUTHORIZATION NUMBER SHALL APPEAR IN THE TITLE BLOCK IN | | | ACCORDANCE WITH FAC RULE 61G15-23.002. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
N |
Date |
2009-02-20 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-02-20 |
Time |
08:08 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-02-19 |
Time |
12:27 |
Sent To |
|
|
| Notes |
| 2009-02-20 08:09:13 | NO PLUMBING WORK SHOWN OR REQUIRED. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2008-11-24 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-11-24 |
Time |
13:25 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-11-24 |
Time |
13:25 |
Sent To |
|
|
| Notes |
| 2008-11-24 13:35:00 | DENIED | | | REFERENCE: FBC-2004 PLUMBING W/2005, 2006 & 2007 | | | REVISIONS | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | FBC-2004 CHAPTER 1 | | | | | | ****FROM PREVIOUS REVIEW: | | | | | | 1. ALL SHEETS. THE CERTIFICATE OF AUTHORIZATION IS | | | REQUIRED IN THE TITLE BLOCK OF THE ENGINEERING COMPANY. | | | FAC 61G15-23.002(2) & FS 471.025. | | | ****NO RESPONSE, COMMENT NOT ADDRESSED. | | | | | | 2. SHT S-2 BASIS OF DESIGN. PLEASE INDICATE ALL | | | REVISIONS TO THE FLORIDA BUILDING CODE, (2005, 2006 & | | | 2007). AS WELL AS THE OCCUPANCY OF THE BUILDING. | | | SECTIONS 106.1 & 106.3.5.1.1. | | | ****NO RESPONSE, COMMENT NOT ADDRESSED. | | | | | | 3. PER TABLE 403.1 MINIMUM FACILITIES, AT LEAST A WATER | | | CLOSET AND LAV ARE REQUIRED AND MAYBE A DRINKING | | | FOUNTAIN. IF TOILET FACILITIES ARE PROVIDED PER SECTION | | | 403.4 EXCEPTION. IF SO PLEASE INDICATE THE LOCATION ON | | | THE PLANS AS WELL AS THE DISTANCE FROM THE GUARD HOUSE | | | TO THE FACILITIES PER SECTION 403.4.1. | | | ****NO RESPONSE, COMMENT NOT ADDRESSED. | | | | | | ***********NEW COMMENTS*********** | | | | | | 1B. PLANS SHALL BE SUBMITTED IN A MINIMUM (TWO) SETS OF | | | PLANS BOUND/STAPLED TOGETHER. PLANS SUBMITTED WERE | | | LOOSE SHEETS. SECTION 106.1. | | | | | | 2B. SEE ATTACHED SHEET CONCERNING FS 553.80(2)(B) AND | | | THE DESIGN PROFESSIONAL. THIS IS GIVEN AS A NOTICE ONLY | | | AT THIS TIME. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2008-09-03 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-09-03 |
Time |
08:27 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-09-03 |
Time |
08:27 |
Sent To |
|
|
| Notes |
| 2008-09-03 08:40:36 | DENIED | | | REFERENCE: FBC-2004 PLUMBING W/2005, 2006 & 2007 | | | REVISIONS | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | FBC-2004 CHAPTER 1 | | | | | | 1. ALL SHEETS. THE CERTIFICATE OF AUTHORIZATION IS | | | REQUIRED IN THE TITLE BLOCK OF THE ENGINEERING COMPANY. | | | FAC 61G15-23.002(2) & FS 471.025. | | | | | | 2. SHT S-2 BASIS OF DESIGN. PLEASE INDICATE ALL | | | REVISIONS TO THE FLORIDA BUILDING CODE, (2005, 2006 & | | | 2007). AS WELL AS THE OCCUPANCY OF THE BUILDING. | | | SECTIONS 106.1 & 106.3.5.1.1. | | | | | | 3. PER TABLE 403.1 MINIMUM FACILITIES, AT LEAST A WATER | | | CLOSET AND LAV ARE REQUIRED AND MAYBE A DRINKING | | | FOUNTAIN. IF TOILET FACILITIES ARE PROVIDED PER SECTION | | | 403.4 EXCEPTION. IF SO PLEASE INDICATE THE LOCATION ON | | | THE PLANS AS WELL AS THE DISTANCE FROM THE GUARD HOUSE | | | TO THE FACILITIES PER SECTION 403.4.1. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2009-01-22 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2009-01-22 |
Time |
17:58 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2009-01-22 |
Time |
17:58 |
Sent To |
|
|
| Notes |
| 2009-01-22 18:39:53 | ZONING PLAN REVIEW | | | | | | PERMIT NO.: 08080664 | | | ADDRESS: 1801 NORTH FLAGLER DRIVE | | | CONTRACTOR/CONTACT: JAY PETRONI | | | TELEPHONE NO.: (561) 346.8449 | | | | | | REVIEW STATUS: FAILED | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | THE FOLLOWING COMMENTS FROM PREVIOUS REVIEWS CONTINUE | | | TO REMAIN UNADDRESSED.... | | | | | | 1) A MINOR AMENDMENT TO THE RESIDENTIAL PLANNED | | | DEVELOPMENT (RPD) SHALL BE SUBMITTED TO, AND APPROVED | | | BY, THE PLANNING AND ZONING DEPARTMENT PRIOR TO | | | ISSUANCE OF A BUILDING PERMIT. NO MINOR AMENDMENT | | | APPLICATION HAS BEEN SUBMITTED TO THE PLANNING AND | | | ZONING DEPARTMENT. | | | | | | 2) PLEASE PROVIDE TWO (2) COPIES OF A CURRENT AND | | | ACCURATE SURVEY OF THE AREA UPON WHICH THE PROPOSED | | | GUARD HOUSE IT TO BE LOCATED. THE SURVEY PROVIDED IS | | | NOT CURRENT, NOR ACCURATE OF THE EXISTING CONDITIONS. | | | THE SURVEY PROVIDED IS DATED 1998 AND WAS PRIOR TO THE | | | CONSTRUCTION OF THE EXISTING DEVELOPMENT. | | | | | | 3) PLEASE PROVIDE A LANDSCAPE PLAN, SIGNED AND SEALED | | | BY A REGISTERED LANDSCAPE ARCHITECT, INDICATING WHAT | | | LANDSCAPING WILL BE PLACED AROUND THE EXTERIOR OF THE | | | GUARD HOUSE. YOUR RESPONSE INDICATES THAT THE EXISTING | | | LANDSCAPING WILL BE MINIMALLY IMPACTED; HOWEVER, IT | | | APPEARS THAT EXISTING PALMS/TREES ARE IN THE LOCATION | | | OF THE PROPOSED GUARD HOUSE. IF SO, A TREE RELOCATION | | | PERMIT WILL BE REQUIRED AND A LANDSCAPE PLAN PREPARED | | | BY A REGISTERED LANDSCAPE ARCHITECT WILL ALSO BE | | | REQUIRED. NO LANDSCAPE PLANS HAVE BEEN SUBMITTED, | | | THEREFORE, THE FULL EXTENT OF THE MODIFICATIONS CANNOT | | | BE DETERMINED. | | | | | | 4) THE FUNCTIONALITY OF THE GUARD HOUSE DOES NOT WORK. | | | THE PROPOSED LOCATION OF THE GUARD HOUSE CONFLICTS WITH | | | TRAFFIC CIRCULATION, PARKING, ETC. PLEASE CONTACT ME | | | PRIOR TO THE SUBMITTAL OF THE MINOR AMENDMENT TO | | | DISCUSS. THE PROPOSED LOCATION CONTINUES TO CONFLICT | | | WITH TRAFFIC CIRCULATION, ETC. THERE IS NO PLACE FOR | | | GUESTS WHO HAVE BEEN REFUSED ENTRY TO TURN AROUND. | | | BECAUSE GUESTS AND RESIDENTS WILL ALL BE UTILIZING THE | | | SAME GATE, CARS WILL BE STACKED, IMPEDEING THE THE | | | PARKING. PLEASE CONTACT ME REGARDING THESE ISSUES. | | | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER, | | | AT (561) 822-1435. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2008-11-17 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2008-11-17 |
Time |
14:59 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2008-11-17 |
Time |
14:59 |
Sent To |
|
|
| Notes |
| 2008-11-17 15:04:46 | ***FAILED*** | | | | | | NO COMMENTS FROM THE FIRST REVIEW WERE ADDRESSED. | | | PLEASE PROVIDE A WRITTEN RESPONSE, AS WELL AS REVISED | | | PLANS, REFLECTING THE FOLLOWING REPEAT COMMENTS: | | | | | | 1) A MINOR AMENDMENT TO THE RESIDENTIAL PLANNED | | | DEVELOPMENT (RPD) SHALL BE SUBMITTED TO, AND APPROVED | | | BY, THE PLANNING AND ZONING DEPARTMENT PRIOR TO | | | ISSUANCE OF A BUILDING PERMIT. | | | | | | 2) PLEASE PROVIDE TWO (2) COPIES OF A CURRENT AND | | | ACCURATE SURVEY OF THE AREA UPON WHICH THE PROPOSED | | | GUARD HOUSE IT TO BE LOCATED. | | | | | | 3) PLEASE PROVIDE THE DIRECTION (I.E. NORTH, SOUTH, | | | EAST, OR WEST) ON THE ELEVATIONS. | | | | | | 4) PLEASE PROVIDE A LANDSCAPE PLAN, SIGNED AND SEALED | | | BY A REGISTERED LANDSCAPE ARCHITECT, INDICATING WHAT | | | LANDSCAPING WILL BE PLACED AROUND THE EXTERIOR OF THE | | | GUARD HOUSE. | | | | | | 5) THE MEASURE OF SCALE SHOWN ON THE SITE PLAN IS | | | INCORRECT. IMPORTANT - NO SITE PLAN WAS INCLUDED AS | | | PART OF THE RESUBMITTAL. PLEASE BE SURE TO INCLUDE A | | | SITE PLAN WITH ALL FUTURE RESUBMITTALS. | | | | | | 6) THE FUNCTIONALITY OF THE GUARD HOUSE DOES NOT WORK. | | | THE PROPOSED LOCATION OF THE GUARD HOUSE CONFLICTS WITH | | | TRAFFIC CIRCULATION, PARKING, ETC. PLEASE CONTACT ME | | | PRIOR TO THE SUBMITTAL OF THE MINOR AMENDMENT TO | | | DISCUSS. | | | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER, | | | AT (561) 822-1435. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2008-09-15 |
|
|
Cont ID |
|
| Sent By |
bpowell |
Date |
2008-09-15 |
Time |
13:54 |
Rev Time |
0.00 |
| Received By |
bpowell |
Date |
2008-09-15 |
Time |
13:54 |
Sent To |
|
|
| Notes |
| 2008-09-15 14:05:06 | 1. A MINOR AMENDMENT TO THE PLANNED DEVELOPMENT SHALL | | | BE APPROVED PRIOR TO SUBMITTING FOR A BUILDING PERMIT. | | | | | | 2. PLEASE INCLUDE TWO (2) COPIES OF A SURVEY. | | | | | | 3. ON THE ELEVATIONS PLEASE INDICATE WHICH SIDE, NORTH | | | OR SOUTH, THE DOORS AND WINDOWS OF THE GUARD HOUSE WILL | | | BE LOCATED ON. | | | | | | 4. PLEASE INCLUDE AN ELEVATION SHOWING WHAT THE SIDE OF | | | THE EXISTING BUILDING WILL LOOK LIKE WHEN THE GUARD | | | HOUSE IS ATTACHED. | | | | | | 5. PLEASE INCLUDE A LANDSCAPE PLAN THAT SHOWS THE | | | LANDSCAPING THAT WILL BE PLACED AROUND THE GUARD HOUSE. | | | | | | 6. THE MEASURE OF SCALE SHOWN ON THE SITE PLAN IS | | | INCORRECT. | | | | | | 7. THE FUNCTIONALITY OF THE GUARD HOUSE DOES NOT WORK. | | | PLEASE SET UP A MEETING WITH STAFF PRIOR TO SUBMITTING | | | FOR THE REQUIRED MINOR AMENDMENT. | | | | | | IF YOU HAVE ANY QUESTIONS OR COMMENTS PLEASE CONTACT: | | | BOBBY POWELL JR., PLANNER, [email protected], (561) | | | 822-1401 |
|
|
|