| Plan Review Stops For Permit 08080615 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2009-01-28 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2009-01-28 |
Time |
10:44 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2009-01-28 |
Time |
10:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2008-12-08 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-12-08 |
Time |
08:30 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-12-08 |
Time |
08:30 |
Sent To |
|
|
| Notes |
| 2008-12-08 08:30:11 | 2ND REVIEW | | | BUILDING PLAN REVIEW | | | PERMIT: 08080615 | | | ADD: 2616 E TAMARIND AVE. | | | CONT: YAVEL CONSTRUCTION | | | TEL: (561)512-9341 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 12-8-08 | | | REVIEW: 2ND | | | ACTION: DENIED | | | | | | 1) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE & REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 2) FL S S 713.13 NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT. NOTE: 713.13(2) IF THE | | | WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS NOT | | | ACTUALLY COMMENCED WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) | | | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE | | | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | | | 3) OK | | | | | | **PARTIALY ADDRESSED: WHAT IS THE USE AND OCCUPANCY** | | | 4) THE PLANS NEED TO INDICATE THE TYPE OF BUILDING PER | | | FBC CHAPTER 6, THE USE AND OCCUPANCY PER CHAPTER 3 AND | | | THE OCCUPANT LOAD PER TABLE 1004.1.2. | | | | | | 5) OK | | | | | | **SOME DETAILS ARE STILL NOT CLEAR. WILL THERE BE A NEW | | | SECTION OF THE FLAT ROOM ADDED? IF SO, PLEASE PROVIDE | | | THE PRODUCT APPROVAL AND INDICATE THE SYSTEM WHICH WILL | | | BE USED. SEE ROOFING POLICY IN PACKAGE.** | | | 6) THE PLANS SHALL CLEARLY SHOW THE EXISTING STRUCTURAL | | | AND FLOOR LAYOUT AND THE PROPOSED CHANGES SHALL BE | | | CLEARLY SHOWN ON THE DRAWINGS. THE DRAWINGS SUBMITTED | | | SHOW NO DISTENTION BETWEEN THE EXISTING LAYOUT AND THE | | | PROPOSED LAYOUT. PRODUCT APPROVALS WERE SUBMITTED FOR | | | TWO DOORS HOWEVER, THE DRAWINGS DO NOT SHOW WHICH DOORS | | | WILL BE CHANGED. CONSTRUCTION DOCUMENTS SHALL BE OF | | | SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND | | | EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT | | | WILL CONFORM TO THE PROVISIONS OF THE CODE. FBC 106.1.1 | | | | | | 7) PROVIDE A DETAIL WALL LEGEND SHOWING THE DIFFERENT | | | TYPES OF WALLS TO BE CONSTRUCTED AND THE EXISTING | | | WALLS. SHOW THE SLOPE OF THE NEW SLAB LEADING TO THE | | | LOADING DOCK AREA ON SHEET 2 OF 3. SOME OF THE DETAIL | | | INFORMATION PERTAINING TO THE COVERED ENTRY IS NOT | | | LEGIBLE. | | | | | | 8) OK | | | | | | 9) SHEET #3 SHOWS THE NEW ROOF JOISTS AS 2X12 SO, HOW | | | CAN THE FASCIA BOARD BE 1X10? ALSO ONE DETAIL SHOWS THE | | | SPACING OF THE JOISTS AT 24 INCHES ON CENTER AND OTHER | | | SHOWS THE SPACING AS 16 INCHES ON CENTER. CLARIFY. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | (561)805-6726 | | | [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-09-10 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-09-10 |
Time |
15:29 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-09-10 |
Time |
09:51 |
Sent To |
|
|
| Notes |
| 2008-09-10 15:29:49 | 9-10-08 | | | BUILDING PLAN REVIEW | | | PERMIT: 08080615 | | | ADD: 2616 E TAMARIND AVE. | | | CONT: YAVEL CONSTRUCTION | | | TEL: (561)512-9341 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW: 1ST | | | ACTION: DENIED | | | | | | 1) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE & REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 2) FL S S 713.13 NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT. NOTE: 713.13(2) IF THE | | | WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS NOT | | | ACTUALLY COMMENCED WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) | | | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE | | | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | | | 3) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) AFTER | | | JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC | | | BUILDING WITH THE 2007 SUPPLEMENTS. | | | | | | 4) THE PLANS NEED TO INDICATE THE TYPE OF BUILDING PER | | | FBC CHAPTER 6, THE USE AND OCCUPANCY PER CHAPTER 3 AND | | | THE OCCUPANT LOAD PER TABLE 1004.1.2. | | | | | | 5) 2004 FBC EXISTING 301.5 A DESIGN PROFESSIONAL OR AN | | | OWNER MUST ELECT ONE OR A COMBINATION OF LEVELS OF | | | ALTERATION PURSUANT TO SECTIONS 303, 304 AND 305 OF | | | THIS CODE. | | | | | | 6) THE PLANS SHALL CLEARLY SHOW THE EXISTING STRUCTURAL | | | AND FLOOR LAYOUT AND THE PROPOSED CHANGES SHALL BE | | | CLEARLY SHOWN ON THE DRAWINGS. THE DRAWINGS SUBMITTED | | | SHOW NO DISTENTION BETWEEN THE EXISTING LAYOUT AND THE | | | PROPOSED LAYOUT. PRODUCT APPROVALS WERE SUBMITTED FOR | | | TWO DOORS HOWEVER, THE DRAWINGS DO NOT SHOW WHICH DOORS | | | WILL BE CHANGED. CONSTRUCTION DOCUMENTS SHALL BE OF | | | SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND | | | EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT | | | WILL CONFORM TO THE PROVISIONS OF THE CODE. FBC 106.1.1 | | | | | | 7) PROVIDE A DETAIL WALL LEGEND SHOWING THE DIFFERENT | | | TYPES OF WALLS TO BE CONSTRUCTED AND THE EXISTING | | | WALLS. SHOW THE SLOPE OF THE NEW SLAB LEADING TO THE | | | LOADING DOCK AREA ON SHEET 2 OF 3. SOME THE DETAIL | | | INFORMATION PERTAINING TO THE COVERED ENTRY IS NOT | | | LEGIBLE. | | | | | | 8) THE PLANS NEED TO STATE THE POINT LOAD, FLOOR LOAD | | | AND CONCENTRATED LOAD OF THE DECK PER FBC 1604.8.3 AND | | | 1607. FOR THE GUARD RAILS SEE 1607.7.1/1607.7.1.1 AND | | | TABLE 1607.1. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | (561)805-6726 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2009-01-26 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-01-26 |
Time |
15:07 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-01-26 |
Time |
14:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2008-12-16 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-12-16 |
Time |
08:21 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-12-08 |
Time |
16:11 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2008-09-03 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-09-03 |
Time |
13:09 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-09-03 |
Time |
12:52 |
Sent To |
|
|
| Notes |
| 2008-09-03 13:08:27 | | | | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2005 | | | NEC, NFPA-72 2002, NFPA-101 2003, 2004 FBC AS AMENDED, | | | CHAPTER 1.AND FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | | | | 1} INDICATE PANEL DESIGNATION AND CIRCUIT NUMBERS FOR | | | DEVICES AND EQUIPMENT TO BE INSTALLED UNDER THIS | | | PERMIT, ALL THAT'S SHOWN IS TWO LIGHT FIXTURES AND ONE | | | SWITCH IN THE STORAGE ROOM INDICATE IF | | | NEW OR EXISTING. 106.3.5 FBC. | | | | | | 2} INDICATE THE CODE CYCLES THIS PROJECT WAS DESIGNED | | | UNDER. 2004 FBC, 2005 NEC ETC. ADD TO NOTES FOR CLARITY | | | IN THE FIELD AND COMPLIANCE WITH 106.1.3 FBC AS | | | AMENDED. | | | | | | 3} EGRESS LIGHTING IS REQUIRED PER 210.70(A)(2)(B).. | | | INDICATE COMPLIANCE ON THE PLAN, IF EXISTING LOCATE | | | SAME. | | | | | | AN ELECTRICAL PERMIT IS REQUIRED FOR THE SCOPE OF WORK | | | PURPOSED. 105.1 FBC AS AMENDED. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2009-01-28 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2009-01-28 |
Time |
11:12 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2009-01-28 |
Time |
10:53 |
Sent To |
|
|
| Notes |
| 2009-01-28 11:09:08 | *****APPROVED***** | | | | | | | | | PLAN SHEETS 1 & 2 (OF 3) WERE STAMPED, INITIALED, AND | | | DATED. | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2008-12-26 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-12-26 |
Time |
11:26 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-12-26 |
Time |
11:26 |
Sent To |
|
|
| Notes |
| 2008-12-26 11:32:29 | ***DENIED*** | | | | | | 1) PROVIDE THE OCCUPANCY CLASSIFICATION IN ACCORDANCE | | | WITH NFPA 101, CHAPTER-6. | | | | | | 2) SHEET 2 ILLUSTRATES THREE (3) NEW EXIT SIGNS. | | | CLEARLY SHOW HOW THE MEANS OF EGRESS LEAD TO EXIT | | | DISCHARGE FROM THE STRUCTURE. | | | | | | 3) SHOW NEW OR EXISTING ADDRESS ON THE BUILDING ON | | | SHEET 1 ELEVATION DRAWING. | | | | | | | | | MIKE WENNERGREN, ASST. FIRE MARSHAL | | | FIRE PLAN REVIEW | | | FIRE PREVENTION (561) 804-4756 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2009-01-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-01-22 |
Time |
11:25 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-01-22 |
Time |
11:25 |
Sent To |
|
|
| Notes |
| 2009-01-22 11:25:19 | TO "BOB"#11 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-12-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-12-16 |
Time |
08:45 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-12-16 |
Time |
08:45 |
Sent To |
P |
|
| Notes |
| 2008-12-16 08:50:48 | TO "BOB"#3 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-12-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-12-04 |
Time |
08:49 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-12-04 |
Time |
08:49 |
Sent To |
|
|
| Notes |
| 2008-12-04 08:51:40 | TO "BOB"#6 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-09-11 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-09-11 |
Time |
08:56 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-08-28 |
Time |
14:55 |
Sent To |
PC |
|
| Notes |
| 2008-08-28 14:57:45 | TO "BOB" BD #4. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2009-02-03 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-02-03 |
Time |
07:54 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-02-02 |
Time |
16:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2008-12-24 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-12-24 |
Time |
15:39 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-12-24 |
Time |
15:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2008-09-11 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-12-16 |
Time |
08:29 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-09-11 |
Time |
08:13 |
Sent To |
I |
|
| Notes |
| 2008-09-11 08:54:39 | PLUMBING PLAN REVIEW: | | | DENIED: | | | | | | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | | PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE. | | | | | | 1. DECLARE THE GOVERNING CODE. (FBC-2004 WITH 2007 | | | REVISIONS). PER (W.P.B. AS AMENDED) SECTION 106.5 | | | RETENTION OF CONSTRUCTION DOCUMENTS. | | | | | | 2. DECLARE THE LEVEL OF ALTERATION. PER FBC-2004 | | | EXISTING BUILDING CHAPTER 3. | | | | | | 3. PER FS 713.13 (1) THRU (6): A NOTICE OF COMMENCEMENT | | | IS REQUIRED FROM THE - PALM BEACH COUNTY COURTHOUSE - | | | 4TH FLOOR RECORDING DEPT. 205 N. DIXIE HWY.. | | | | | | 4. SHEET 2 OF 3, "B" TRENCH DRAIN DETAIL: CLEARLY | | | INDICATE ON THE RESUBMITTED PLANS THE FOLLOWING | | | INFORMATION PER THE FOLLOWING FBC-2004 PLUMBING | | | SECTIONS. | | | | | | A} CLEARLY INDICATE THE SIZE OF THE TRENCH DRAIN. IS | | | THIS A PREFABRICATED TRENCH DRAIN? IF THIS IS A | | | PREFABRICATED TRENCH DRAIN CLEARLY INDICATE THE MAKE | | | AND MODEL NUMBER ON THE DETAIL. PER SECTION 1101.1 | | | SCOPE. | | | | | | B} CLEARLY INDICATE WHERE THE DISCHAGE OF THE STORM | | | WATER FOR THE TRENCH DRAIN IS LOCATED AND THE SIZE OF | | | THE DRAIN PIPE ON THE RESUBMITTED PLANS. WILL THE | | | TRENCH DRAIN DISCHARGE INTO AN EXISTING CATCH BASIN OR | | | UNDERGROUND STORM PIPE? PLEASE CLARIFY THIS PER SECTION | | | 1101.1 SCOPE. | | | | | | 5. SHEET 2 OF 3, 1ST FLOOR PLAN IS INDICATING A STORAGE | | | ROOM ADDITION. PLEASE PROVIDE A ROOF PLAN THAT | | | INDICATES HOW THE ROOF WILL BE PITCHED TO PROPERLY | | | DRAIN, AND INDICATE THE FOLLOWING INFORMATION PER THE | | | FOLLOWING CODE REFERENCES. | | | A} DETAIL OF ROOF INDICATING SQUARE FOOTAGE OF ROOF AND | | | VERTICAL WALLS (PARAPHET) DRAINING TO DOWNSPOUTS AND | | | SCUPPERS TO VERIFY COMPLIANCE WITH FBC-2004 PLUMBING, | | | SECTION 1106. | | | B} VERTICAL CONDUCTORS AND LEADERS, PER FBC-2004 | | | PLUMBING, SECTION 1106.2 | | | C} VERTICAL WALLS, PER FBC-2004 PLUMBING, SECTION | | | 1106.4 | | | D} SCUPPERS, (PROVIDE DETAIL PER FBC-2004 BUILDING, | | | SECTIONS 1503.4.2 AND 1503.4.3) SIZE PER FBC-2004 | | | PLUMBING, TABLE 1106.7. | | | E} SECONDARY (EMERGENCY) ROOF DRAINS, PER FBC-2004 | | | PLUMBING, SECTION 1107. | | | A) SECONDARY DRAINAGE REQUIRED, PER FBC-2004 PLUMBING, | | | SECTION 1107.1. | | | B) SEPERATE SYSTEMS REQUIRED PER FBC-2004 PLUMBING, | | | SECTION 1107.2. | | | | | | 6. SHEET 2 OF 3, COVER ENTRY AND BALCONY DETAIL DOES | | | NOT CLEARLY INDICATE HOW THE BALCONY WILL DRAIN STORM | | | WATER. PLEASE CLARIFY THE DETAILAND CLEARLY INDICATE | | | HOW THE BALCONY WILL DISCHARGE STORM WATER. PRIMARY AND | | | SECONDARY DRAINS MAY BE REQUIRED FOR THE BALCONY. PER | | | FBC-2004 PLUMBING SECTION 1101.1 SCOPE. | | | | | | ********IMPORTANT INFORMATION******** | | | WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE | | | OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW | | | PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | PHONE= (561) 805-6730 | | | FAX= (561) 805-6731 | | | E-MAIL= [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2009-01-27 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2009-01-27 |
Time |
16:35 |
Rev Time |
0.50 |
| Received By |
eschneid |
Date |
2009-01-27 |
Time |
16:35 |
Sent To |
|
|
| Notes |
| 2009-01-27 16:40:50 | PASSED W/PROVISO | | | | | | A SHADE OR FLOWERING TREE SHALL BE PLANTED IN THE | | | SOUTHEAST CORNER OF THE SITE (OUTSIDE OF THE 15 FOOT | | | EASEMENT) PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF | | | OCCUPANCY. THE TREE SHALL BE PLANTED IN ACCORDANCE WITH | | | THE PLANTING DIAGRAM ATTACHED TO THE PLAN. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1435. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2008-09-09 |
|
|
Cont ID |
|
| Sent By |
adavila |
Date |
2008-09-09 |
Time |
13:52 |
Rev Time |
0.00 |
| Received By |
adavila |
Date |
2008-09-09 |
Time |
13:51 |
Sent To |
|
|
| Notes |
| 2008-09-09 13:53:00 | PROVISO SHADE/FLOWER TREE SHALL BE PLANTED ON THE | | | SOUTHEAST CORNER OF THE SITE AS SHOWN ON THE SURVEY PER | | | THE ATTACHED PLANTING DETAILS. | | | | | | PER ERIC SCHNEIDER, PRINCIPAL PLANNER. | | | | | | COMMENTS/QUESTIONS, CONTACT ANDREINA DAVILA Q. OR ERIC | | | SCHNEIDER, PRINCIPAL PLANNER, AT 822-1435. | | | |
|
|