Plan Review Details - Permit 08080340
Plan Review Stops For Permit 08080340
Review Stop B BUILDING (STRUCTURAL)
Rev No 7 Status P Date 2009-05-21 Cont ID  
Sent By jwitmer Date 2009-05-21 Time 11:55 Rev Time 0.95
Received By jwitmer Date 2009-05-21 Time 11:00 Sent To PC
Notes
2009-05-21 11:47:43REVISION: SHEET 1.2A & 1.0A REVISON DATED 5/08/09

Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status   Date 2009-05-21 Cont ID  
Sent By jwitmer Date 2009-05-21 Time 10:57 Rev Time 0.00
Received By jwitmer Date 2009-05-21 Time 10:57 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2009-04-30 Cont ID  
Sent By jwitmer Date 2009-04-30 Time 13:07 Rev Time 0.77
Received By jwitmer Date 2009-04-30 Time 13:07 Sent To  
Notes
2009-04-30 13:09:01ARCHITRCTURAL SHEETS C-1, 1.1A & 1.2A.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2009-03-17 Cont ID  
Sent By jwitmer Date 2009-03-17 Time 14:23 Rev Time 0.77
Received By jwitmer Date 2009-03-17 Time 14:23 Sent To  
Notes
2009-03-17 14:24:53REVISED: SHEET A1.2 DATED FEB.13,09

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2008-12-10 Cont ID  
Sent By jwitmer Date 2008-12-10 Time 08:13 Rev Time 0.22
Received By jwitmer Date 2008-12-10 Time 08:13 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2008-10-24 Cont ID  
Sent By jwitmer Date 2008-10-24 Time 16:26 Rev Time 0.77
Received By jwitmer Date 2008-10-24 Time 16:26 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-09-02 Cont ID  
Sent By jwitmer Date 2008-09-02 Time 09:50 Rev Time 1.22
Received By jwitmer Date 2008-09-02 Time 09:50 Sent To  
Notes
2008-09-02 10:11:25BUILDING PLAN REVIEW
 PERMIT: 08080340
 ADD: 1645 PALM BEACH LAKES # 900
 CONT: LTI DEVELOPMENT
 TEL: (561)718-6243
  
 SEPT. 02.08
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW
 ACTION: DENIED
  
 1A) INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE
 INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 1B) INFORMATIONAL FL S S 713.13 NOTICE OF COMMENCEMENT,
 TO BE FILED WITH THE CLERK OF THE COURT. NOTE:
 713.13(2) IF THE WORK DESCRIBED IN THE NOTICE OF
 COMMENCEMENT IS NOT ACTUALLY COMMENCED WITHIN 90 DAYS
 AFTER THE RECORDING THEREOF, SUCH NOTICE IS NULL &
 VOID. NOTE: 713.13(6) THE POSTING OF THE NOTICE OF
 COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE THE FIRST
 INSPECTION919.
  
 2) 110.2* W. P. B. ADMINISTRATIVE CODE, INFORMATION
 THAT IS REQUIRED FOR RECORD KEEPING & FOR CERTIFICATE
 OF OCCUPANCY:
  
 A) THE EDITION OFTHE CODE UNDER WHICH THE PROJECT IS
 DESIGNED. PLANS SUBMITTED FOR PERMIT (FIRST TIME
 REVIEW) AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO THE
 2004 FBC BUILDING WITH THE 2007 SUPPLEMENTS.
 2004 EXISTING BUILDING CODE/ 2007 SUPPLEMENTS.
 B) LEVEL OF ALTERATION: 2004 EXISTING BUILDING CODE
 301.5 A DESIGN PROFESSIONAL MUST ELECT ONE LEVEL OF
 ALTERATION PURSUANT TO SECTION 303,304 & 305.
 C) THE USE AND OCCUPANCY, IN ACCORDANCE WITH THE
 PROVISIONS OF CHAPTER 3.
 D) THE TYPE OF CONSTRUCTION AS DEFINED IN CHAPTER 6,
 TABLE 601.
 E) IF AN AUTOMATIC SPRINKLER SYSTEM IS PROVIDED
 F) WHETHER THE SPRINKLER SYSTEM IS REQUIRED.
 G) ANY SPECIAL STIPULATIONS & CONDITIONS OF THE
 BUILDING PERMIT
 .
 3) SHEET 1.0A INDICATE A NEW BREAK ROOM BUT THERE IS NO
 INFORMATION ON THE BREAK ROOM CABINETS COUNTER AND
 SINK. PLEASE PROVIDE COMPLIANCE WITH: SINKS:
 11-4.24.2 SINKS, HEIGHT. SINKS SHALL BE MOUNTED WITH
 THE COUNTER NO HIGHER THAN 34" ABOVE THE FINISH FLOOR.
 11-4.24.3 KNEE CLEARANCE THAT IS AT LEAST 27" HIGH 30"
 WIDE, AND 19" DEEP SHALL BE PROVIDED UNDERNEATH SINKS.
 11-4.2.4 SHALL BE PROVIDED IN FRONT OF A SINK TO ALLOW
 FORWARD APPROACH. THE CLEAR FLOOR SPACE SHALL BE ON AN
 ACCESSIBLE ROUTE AND SHALL EXTEND A MAXIMUM OF 19
 INCHES (485 MM) UNDERNEATH THE SINK
 11-4.24.5 CLEAR FLOOR SPACE. A CLEAR FLOOR SPACE AT
 LEAST 30 INCHES BY 48 INCHES (760 MM BY 1219 MM)
 COMPLYING WITH SECTION 11-4.2.4
  
 4) SHEET 1.0A INDICATES A NEW BREAK ROOM WITH NEW WASTE
 LINES BUT NO PLUMBING DETAILS NOR FIRE PROOFING DETAILS
 WHERE THE WASTE WILL PENETRATE THE FIRE RATED FLOOR
 ASSEMBLY. 712.4.1.
  
 5) SHEET 2.0E THE RIGHT SET OF STAIRS IS MISSING THE
 EXIT LIGHT AT THE ENTRY OF THE VERTICAL EXIT. TABLE
 1006.
  
 6) PLANS DO NOT INDICATE THAT NO COMBUSTIBLE MATERIALS
 CAN BE USED IN THE CONSTRUCTION OF WALL FRAMING. TABLE
 601, AND SECTION 603.
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)659-8026
 E-MAIL: [email protected]
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.

Review Stop E ELECTRICAL
Rev No 6 Status P Date 2009-05-05 Cont ID  
Sent By dpalmer Date 2009-05-05 Time 15:08 Rev Time 0.00
Received By dpalmer Date 2009-05-05 Time 15:08 Sent To PC
Notes
2009-05-05 15:10:238TH FLOOR PANEL TO BE REVISED TO MEET 408.4

Review Stop E ELECTRICAL
Rev No 5 Status F Date 2009-03-26 Cont ID  
Sent By mawillia Date 2009-05-05 Time 11:28 Rev Time 0.00
Received By dpalmer Date 2009-03-26 Time 15:45 Sent To  
Notes
2009-03-26 15:46:35** DENIED REVIEW **
  
 *** PLEASE SEE ALL NOTES ISSUED ON PROVISO DATED
 12/18/08. MOST OF THESE COMMENTS STILL NEED TO BE
 ADDRESSED.
  
 1) NOTE: CIRCUITING ON PLANS NEEDS TO COORDINATE WITH
 ALL PANEL SCHEDULES AND ALL ELECTRICAL ON PLANS NEEDS
 TO BE CIRCUIT. SOME EXAMPLES WILL BE GIVEN.
  
 FOR EXAMPLE: PLEASE SEE LIGHTING FIXTURES IN AREA 931
 WHICH DO NOT SHOW ANY CONTROLS OR CIRCUITING.
 THIS WILL ALSO BE NOTED FOR FBC CHAPTER 13 COMMENTS
 WITH RESPECT TO MINIMUM LIGHTING CONTROLS REQUIRED.
  
 FOR EXAMPLE: PLEASE SEE LIGHTING OUTSIDE 918 AND 919 IN
 HALLWAY WHICH DO NOT INDICATE ANY CONTROLS OR
 CIRCUITING.
 THIS WILL ALSO BE NOTED FOR FBC CHAPTER 13 COMMENTS
 WITH RESPECT TO MINIMUM LIGHTING CONTROLS REQUIRED.
  
 FOR EXAMPLE: PLEASE SEE CIRCUITS L9L29 THIS DOES NOT
 CORRELATE WITH THE ROOM/AREA DESIGNATION ON PLANS AND
 PANEL SCHEDULES. ANOTHER WOULD BE L9L14, L9L28, THESE
 ARE SOME EXAMPLES AND ARE NOT ALL.
  
 408.4.
 FBC 106.1.2, 106.1.1, 106.5
  
 2) NOTE: AS NOTED ABOVE WITH RESPECT TO LIGHTING
 CONTROLS THERE ARE LIGHTING FIXTURES WHICH DO NOT
 INDICATE LIGHTING CONTROLS MEETING FBC
 13-415.1.ABC.1.1, .1.2.
 PLEASE SEE PREVIOUS NOTES WITH RESPECT TO KEYPADS AND
 INFORMATION NEEDED.
 PLEASE PROVIDE.
  
 3) NOTE: PLEASE VERIFY NEW RECEPTACLES FOR
 COPIERS/PRINTERS. CIRCUITS L9L23, AND L9R15 BOTH APPEAR
 TO BE FOR COPIERS HOWEVER ONE IS NOTED FOR A PRINTER?
 THIS DOES NOT ACCURATE.
 4108.4, 220, 240.4 ETC.
  
 4) NOTE: PLEASE CORRELATE RISER WITH PANEL SCHEDULES
 AND PLANS.
 FOR EXAMPLE: THE RISER INDICATES PANELS 8L AND 8LA,
 HOWEVER THE PANEL SCHEDULES SUBMITTED ARE FOR L9L, L9R,
 L9LA.
 THERE ARE NOT ANY OF THESE PANELS ON RISER. IN FACT
 WHAT IS L9LA?
 THE RISER INDICATES A 24CIRCUIT PANEL OF SOME SORT FROM
 8L HOWEVER THIS CAN ONLY BE ASSUMED TO BE THE LIGHTING
 CONTROL PANEL. AS THE PANEL SCHEDULE ONLY STATES SUB
 PANEL ON L9L IT IS NOT CLEAR.
 THIS ALSO NOW INCLUDES WORK ON THE 8TH FLOOR WHICH WAS
 NOT PART OF ORIGINAL PLANS, PANEL SCHEDULES, RISER ETC.
 PANEL *H* WHICH IS ONLY NOW BEING SUBMITTED FOR THE
 FIRST TIME TO REVIEW IS SHOWN AS 120/208 YET RISER
 CLEARLY INDICATES THIS AS 277/480V.
 NOTE MENTIONS LOADS ON PANELS WERE NOT KNOWN HOWEVER
 BASED ON THE INITIAL DATE GIVEN ON PROVISO, LOADS MOST
 CERTAINLY COULD HAVE BEEN RECORDED AND INDICATED.
  
 PLEASE COORDINATE ALL PLANS, CIRCUITS, PANELS, RISER AS
 NOTED ON ORIGINAL PROVISO.
 408,215.5, 220,310,ETC GIVEN AS SOME GENERAL CODE
 SECTIONS.
  
 5) NOTE: PLEASE SEE PREVIOUS PROVISO NOTES FOR
 COMPLIANCE WIHT FBC 11-4.28.1, .2 AND .3. NOT
 ADDRESSED. SEE SEPARATE NOTES PRINTED OUT AND ATTACHED
 FROM PROVISO.
  
 IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT
 TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO
 CONTACT THIS REVIEWER.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2008-12-18 Cont ID  
Sent By dpalmer Date 2008-12-18 Time 16:31 Rev Time 0.00
Received By dpalmer Date 2008-12-18 Time 16:31 Sent To  
Notes
2008-12-18 16:31:22** PROVISO **
  
 1) NOTE: PLEASE SUBMIT PLANS WITH REVISED CIRCUITING
 FOR ALL LIGHTING AND RECEPTACLES. SOME NEW RECEPTACLES
 ARE STILL SHOWN WITH OUT ANY CIRCUITS?
 PLEASE BE SURE TO SUBMIT A REVISED PANEL SCHEDULE FOR
 THE 277/480V LIGHTING PANEL WHICH IS NOT SUBMITTED OR
 SHOWN.
 *** NEW CIRCUITS SHALL BE IDENTIFIED. 408.4 SCHEDULE ON
 SITE SHALL ALSO IDENTIFY ALL EXISTING.
 ALL SHALL BE REVISED. VERIFY 30 CIRCUIT 225AMP PANELS
 AS SHOWN ON SCHEDULES AND RISER.
  
 2) NOTE: PLEASE SUBMIT A REVISED SHEET 1.1A FOR MINIMUM
 REQUIRED LEVELS FOR ADA COMPLIANCE. THIS WAS IN
 PREVIOUS COMMENTS HOWEVER THE SHEET SUBMITTED ONLY
 QUOTES THE CODE. CD LEVELS WERE REVISED ON ELECTRICAL.
 FBC 11-4.28.1,.2 AND .3.
  
 3) NOTE: NO NOTES WERE ADDED WITH RESPECT TO KEYPADS
 MEETING THE EXCEPTIONS OF FBC 13-415.1.ABC.1.1,1.2. THE
 OCCUPANT MUST SEE ALL LIGHTING WHICH IS BEING
 CONTROLLED OR MEET EXCEPTIONS.
 PILOT LIGHTS WITH PERMANENT LABELING OF AREAS AND ROOMS
 WHICH ARE BEING CONTROLLED ARE REQUIRED.
  
 4) NOTE: LOAD ON TWO COPIERS SHALL BE VERIFIED AS THESE
 ARE SHOWN ON GENERAL RECEPTACLES CIRCUITS.
 PREVIOUS PLANS INDICATED TWO NEW DEDICATED CIRCUITS
 HOWEVER THESE ARE NOW ON GENERAL RECEPTACLE CIRCUITS.
 220,408.4,310.16,240.4
  
 ** THE ABOVE SHALL BE SUBMITTED FOR REVIEW AND STAMPING
 BEFORE FINAL INSPECTION.
  
 ** ELECTRICAL PERMIT REQUIRED.
 ** LOW VOLTAGE WORK AS SHOWN IS REQUIRED TO BE ON A
 SEPARATE PERMIT FROM ELECTRICAL PERMIT. THESE PLANS MAY
 BE REFERENCED FOR THIS SCOPE OF WORK AS SHOWN.
  
 IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT
 TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO
 CONTACT THIS REVIEWER.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2008-12-05 Cont ID  
Sent By dpalmer Date 2008-12-05 Time 17:08 Rev Time 0.00
Received By dpalmer Date 2008-12-05 Time 17:08 Sent To  
Notes
2008-12-05 17:09:14 
 ** DENIED REVIEW **
  
 ** A CALL WAS PLACED TO THE ELECTRICAL DESIGNER FOR
 CORRECTIONS. EVERY ITEM ON PLANS WAS GONE OVER WITH
 PETE RUSSO.
  
  
  
  
  
 1) NOTE: CIRCUITING ON PLANS FOR NEW ITEMS NOT COMPLETE
 AT THIS TIME. MANY ARE NOT LABELED NEW OR EXISTING.
 SOME ITEMS ON LIGHTING PLANS ARE NOT SHOWN AS NEW OR
 EXISTING. SOME DO NOT SHOW REQUIRED CONTROLS PER
 CHAPTER 13.
 NOTES NEED ADJUSTING.
 408.4,310.16.240.4,13-415.1.ABC.1.1,.1.2, .1.3 ETC.
  
 2) NOTE: CANDELA LEVELS FOR STROBES NOT PER FBC
 11-4.28.3(4). 75MIN
  
 3) NOTE: COORDINATION OF PHONE, DATA, ETC NEEDED.
  
 4) NOTE: AS REQUESTED ON PREVIOUS REVIEW PLEASE REMOVE
 OLD/VOIDED SHEETS AND INSERT NEW SHEETS INTO COMPLETE
 SETS. THIS WAS DONE BY THIS REVIEWER THIS TIME.
  
  
  
  
  
 **IMPORTANT**
 ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP
 FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE
 ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING.
 DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS.
 PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY
 ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS,
 SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED
 INTO TWO SETS/FOLDERS/BINDERS ETC.
 PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS
 SHOULD BE SUBMITTED FOR REFERENCE.
 THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID
 ANY DELAYS.
  
 IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT
 TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO
 CONTACT THIS REVIEWER.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2008-10-29 Cont ID  
Sent By dpalmer Date 2008-10-29 Time 11:22 Rev Time 0.00
Received By dpalmer Date 2008-10-29 Time 11:22 Sent To  
Notes
2008-10-29 11:22:45 
  
  
  
  
  
  
 ** DENIED 2ND REVIEW**
  
  
 ** THERE ARE SOME NOTES FROM PREVIOUS REVIEW WHICH ARE
 STILL IN NEED OF BEING ADDRESSED.
  
  
  
 1) NOTE: PREVIOUS REVIEW NOTE #2 WITH RESPECT TO
 LIGHTING CONTROLS AND PROPOSED SYSTEM. AN OCCUPANT IS
 REQUIRED TO SEE ALL LIGHTING WHICH IS BEING CONTROLLED
 BY THE CONTROL DEVICE WHICH IS INDICATED AS SOME SORT
 OF *KEYPAD*. THE OTHER OPTION IS TO MEET THE EXCEPTION
 TO THE SECTION OF THE CODE HOWEVER THE PLANS DO NOT
 SHOW NAY DETAILS OF THE SYSTEM.
 PLEASE LIST SCHEDULING.
 PLEASE LIST MAXIMUM OVER RIDE TIMES WITH THE AUTOMATIC
 SHUT OFF OF LIGHTING.
 PLEASE SEE THE PLANS DO NOT INDICATE ANY INDICATOR
 PANEL/PILOT LIGHTS WITH NOTES FOR LABELING ETC
 PLEASE SEE NO MAXIMUM TIMES ARE LISTED.
 PLEASE INCLUDE THE SYSTEM DETAILS.
 13-415.1.ABC.1.1, .1.2, .1.3.
 ** PLEASE SEE THE PANEL SCHEDULE FOR CIRCUITS L9L22 AND
 24 WHICH NOTE NEW INCANDESCENT LIGHTING YET THE PLANS
 DO NOT INDICATE ANY OF THESE. IN FACT THE ROOM 914
 (BASED ON ARCHITECTURAL PLANS) SHOWS A JUNCTION BOX
 HOWEVER NO ALLOWANCE FOR A FIXTURE.
 PLEASE INCLUDE OTHER SINGLE FLUORESCENT FIXTURE IN
 ROOM.
 *** ROOM DESIGNATION LAYER DID NOT PRINT ON THE
 ELECTRICAL PLANS.
  
 2) NOTE: PLEASE SEE PREVIOUS REVIEW NOTE #4. THE PANEL
 ON THE SECONDARY SIDE OF THE TRANSFORMER DOES NOT MEET
 408.36,240.21,310.16.240.4 ETC
 THE PANEL IS STILL SHOWN AS A 225AMP MLO PANEL.
 SECTIONS AS NOTED REQUIRE A MAIN TO BE INSTALLED.
 PLEASE BE SURE TO SEE THE FOLLOWING COMMENT WITH
 RESPECT TO THE SIZE OF THE MAIN PERMITTED.
 **
 THE RESPONSE MENTIONS THIS WAS INSTALLED AND INSPECTED
 PREVIOUSLY OVER THE YEARS. BASICALLY STATING THEREFORE
 IT IS ACCEPTABLE AND IT SHOULD BE ACCEPTABLE TO
 CONTINUE WITH THIS VIOLATION OF CODE AND LIFE SAFETY
 ISSUES.
 THESE ARE NOT ONLY CLEAR VIOLATIONS HOWEVER THIS
 CREATES A LIFE SAFETY AND FIRE HAZARD. THE OCCUPANT MAY
 RECEIVE A WRITTEN CORRECTION NOTICE AT ANY TIME WHETHER
 OR NOT THE WORK WAS OR WAS DONE WITH PERMITS, PLANS,
 AND/OR INSPECTIONS. IF THE CORRECTION TO THE EQUIPMENT
 IS NOT A COURSE OF ACTION DESIRED PLEASE LET THIS
 OFFICE KNOW AND AN ON-SITE PRE-INSPECTION WILL TAKE
 PLACE. A CORRECTION NOTICE BY THIS OFFICE AS WELL AS
 THE FIRE MARSHAL OFFICE WILL BE ISSUED. THESE ARE NOT
 NEW CODES IN FACT THESE CODES GO BACK MANY CODE CYCLES
 EVEN WHEN THIS BUILDING WAS CONSTRUCTED.
  
 3) NOTE: PLEASE SEE PREVIOUS REVIEW #5 WITH RESPECT TO
 THE CONDUCTORS ON THE SECONDARY SIDE OF THE TRANSFORMER
 AS SHOWN NOT MEETING 240.21,310.16,240.4 ETC.
 THE CONDUCTORS ON THE SECONDARY SIDE OF THE TRANSFORMER
 ARE TAPPED CONDUCTORS BY WHICH 240.21 REQUIRES
 TERMINATION IN OVER CURRENT PROTECTION. AS THE PANEL IS
 SHOWN AS A MAIN LUG ONLY (MLO) PANEL THERE IS NOT OVER
 CURRENT PROTECTION WHICH LIMITS THE LOAD ON THE
 CONDUCTORS. AS NOTED ABOVE IN NOTE #2 SECTION 408.36 OF
 THE NEC REQUIRES A MAIN. PLEASE BE SURE TO SIZE MAIN
 ACCORDING TO LOAD AND THE PROTECTION OF THE CONDUCTORS
 WHICH ARE SHOWN AS 1/0. PLEASE SEE 310.16,240.4 FOR
 SIZING.
 **
 **
 THE RESPONSE MENTIONS THIS WAS INSTALLED AND INSPECTED
 PREVIOUSLY OVER THE YEARS. BASICALLY STATING THEREFORE
 IT IS ACCEPTABLE AND IT SHOULD BE ACCEPTABLE TO
 CONTINUE WITH THIS VIOLATION OF CODE AND LIFE SAFETY
 ISSUES.
 THESE ARE NOT ONLY CLEAR VIOLATIONS HOWEVER THIS
 CREATES A LIFE SAFETY AND FIRE HAZARD. THE OCCUPANT MAY
 RECEIVE A WRITTEN CORRECTION NOTICE AT ANY TIME WHETHER
 OR NOT THE WORK WAS OR WAS DONE WITH PERMITS, PLANS,
 AND/OR INSPECTIONS. IF THE CORRECTION TO THE EQUIPMENT
 IS NOT A COURSE OF ACTION DESIRED PLEASE LET THIS
 OFFICE KNOW AND AN ON-SITE PRE-INSPECTION WILL TAKE
 PLACE. A CORRECTION NOTICE BY THIS OFFICE AS WELL AS
 THE FIRE MARSHAL OFFICE WILL BE ISSUED. THESE ARE NOT
 NEW CODES IN FACT THESE CODES GO BACK MANY CODE CYCLES
 EVEN WHEN THIS BUILDING WAS CONSTRUCTED.
  
 4) NOTE: PLEASE SEE THE RISER SHOWS SOME DIFFERENCES IN
 THE PANELS. RISER AND PANEL SCHEDULES INDICATE TWO
 PANELS. ONE L9L AND ONE L9R. YET RISER STILL SHOWS TWO
 L9L. PLEASE ADJUST MISPRINT.
 NO PANEL SCHEDULE SUBMITTED FOR THE HIGH VOLTAGE
 (277/480V PANEL). IT IS BEING ASSUMED NO WORK IS BEING
 PERFORMED IN THAT PANEL.
 PLEASE SEE SOME CIRCUITS ON PLANS SEEM TO CONTAIN A
 NUMERICAL CIRCUIT NUMBER WHICH IS NOT ON EITHER PANEL
 SCHEDULE. FOR EXAMPLE SEE LOBBY AREA TABLE WHICH SHOWS
 A L9L62.
 PLEASE SEE OTHER ROOMS SUCH AS ROOM 904 WHICH HAS NEW
 RECEPTACLES SHOWN HOWEVER NO NEW CIRCUITING INDICATED.
 ** THERE ARE OTHERS.
 408.4,310.16
 FBC 106.1.1, 106.1.2
  
  
  
 5) NOTE: PLEASE SEE PREVIOUS REVIEW NOTE #5. PLEASE
 SHOW AND INDICATE ALL MINIMUM DEVICE LOCATIONS AND
 LEVELS PER FBC 11-4.28.1,.2 AND .3.
 BASE PLANS ARE REQUIRED TO MINIMUM DESIGN FIRE ALARM
 SYSTEM PER FS 633.
  
 6) NOTE: NOTICE TO FS 553.80(2)(B) IS GIVEN WITH
 RESPECT TO REPEAT COMMENTS. THIS IS ONLY A NOTICE.
  
  
  
  
  
 **IMPORTANT**
 ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP
 FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE
 ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING.
 DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS.
 PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY
 ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS,
 SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED
 INTO TWO SETS/FOLDERS/BINDERS ETC.
 PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS
 SHOULD BE SUBMITTED FOR REFERENCE.
 THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID
 ANY DELAYS.
  
  
 IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT
 TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO
 CONTACT THIS REVIEWER.
  
  
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2008-08-29 Cont ID  
Sent By dpalmer Date 2008-08-29 Time 16:06 Rev Time 0.00
Received By dpalmer Date 2008-08-29 Time 16:06 Sent To  
Notes
2008-08-29 16:07:01 
  
  
  
  
 ** DENIED **
  
  
  
 1) NOTE: PLANS NEED TO INDICATE THE MINIMUM CODES AS
 NOTED BELOW FOR DESIGN.
 2004 FBC W/ 2007 REVISIONS.
 2005 NFPA-70
 2003 NFPA-101
  
 2) NOTE: PLANS NEED TO BE COMPLETED FOR LIGHTING
 CONTROL SYSTEM PER 13-415.1.ABC.1.1, .1.2 AND .1.3.
 STATING ON PLANS THAT THE SYSTEM SHALL BE LUTRON SOFT
 TOUCH OR EQUAL DOES NOT PROVIDE ENOUGH INFORMATION FOR
 REVIEW. PLEASE SHOW ALL DEVICES, LOCATIONS, OVER RIDES,
 OVER RIDE TIMES ETC
  
 3) NOTE: PLEASE PROVIDE LIGHTING PERFORMANCE
 CALCULATIONS PER 13-415.2, 13-415.2.ABC.1.1,.1.2
 PLEASE COMPLETE FIXTURE LEGEND ETC. AS THIS IS NOT
 COMPLETE AT THIS TIME THE LIGHTING PERFORMANCE LEVELS
 AS SHOWN CAN NOT BE CONFIRMED TO BE CODE COMPLIANT.
  
 4) NOTE: PLEASE SEE THAT PANEL ON SECONDARY SIDE OF
 TRANSFORMER SHALL MEET 408.36, 240.21, 310.16, 240.4
  
 5) NOTE: PLEASE SEE FEEDERS ON THE SECONDARY SIDE OF
 TRANSFORMER SHALL MEET 240.21, 310.16, 240.4
  
 6) NOTE: PLEASE SEE 408.4, ALL NEW CIRCUITS SHALL BE
 SPECIFIC TO ROOMS AND AREAS IN WHICH THEY FEED. STATING
 *RECEPTACLES* OR *LIGHTING* IS NOT PERMITTED.
  
 7) NOTE: PLEASE PROVIDE NOTES ON PLANS PER
 13-413.1.ABC.2.1, .2.2
  
 8) NOTE: PLEASE COORDINATE PLANS. THE ELECTRICAL
 SERVICE EQUIPMENT SHOWN ON PLANS IS NOT THAT OF THE
 SAME EQUIPMENT SHOWN ON RISER AND PANEL SCHEDULES.
 220,215,408,310,ETC
 FBC 106.1.1 FOR CLARITY AND COORDINATION OF DOCUMENTS.
 FBC 106.3.5.1.2 FOR COMPLETED PLANS.
  
 9) NOTE: PLEASE SHWO AND INDICATE ALL MINIMUM DEVICE
 LOCATIONS AND LEVELS PER FBC 11-4.28.1,.2 AND .3.
 BASE PLANS ARE REQUIRED TO MINIMUM DEISGN FIRE ALARM
 SYSTEM PER FS 633
  
  
  
  
  
 **IMPORTANT**
 ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP
 FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE
 ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING.
 DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS.
 PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY
 ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS,
 SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO
 TWO SETS/FOLDERS/BINDERS ETC.
 PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS
 SHOULD BE SUBMITTED FOR REFERENCE.
 THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID
 ANY DELAYS.
  
  
 IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT
 TYPED IN A CLEAR MANOR PLEASE DO NOT HESITATE TO
 CONTACT THIS REVIEWER.
  
  
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 6 Status P Date 2009-05-21 Cont ID  
Sent By mawillia Date 2009-05-21 Time 11:41 Rev Time 0.00
Received By mawillia Date 2009-05-21 Time 11:38 Sent To  
Notes
2009-05-21 11:41:08*****REVISION, DATED 5/08/2009, APPROVED*****
  
 REVISED PLAN SHEETS 1.2A AND 1.0A WERE STAMPED,
 INITIALED, AND DATED.
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 5 Status P Date 2009-05-05 Cont ID  
Sent By mawillia Date 2009-05-05 Time 11:26 Rev Time 0.00
Received By mawillia Date 2009-05-05 Time 11:15 Sent To E
Notes
2009-05-05 11:26:24*****REVISION APPROVED*****
  
 REVISED PLAN SHEETS 1.1A AND 2.0E WERE STAMPED,
 INITIALED, AND DATED.

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status P Date 2009-03-31 Cont ID  
Sent By mawillia Date 2009-03-31 Time 13:15 Rev Time 0.00
Received By mawillia Date 2009-03-31 Time 13:01 Sent To  
Notes
2009-03-31 13:15:38*****PROVISO*****
  
 REVISED PLAN SHEET 2.0E TO BE FIRE-STAMPED WHEN THE
 ELCTRICAL PLAN EXAMINER'S COMMENTS HAVE BEEN ADDRESSED.
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2008-12-12 Cont ID  
Sent By mwennerg Date 2008-12-12 Time 13:13 Rev Time 0.00
Received By mwennerg Date 2008-12-12 Time 13:13 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2008-10-31 Cont ID  
Sent By mwennerg Date 2008-10-31 Time 11:06 Rev Time 0.00
Received By mwennerg Date 2008-10-31 Time 11:06 Sent To  
Notes
2008-10-31 11:07:43PLANS STAMPED SEPARATE SHOP DRAWINGS AND PERMITS
 REQUIRED FOR FIRE SPRINKLER AND FIRE ALARM REMODEL.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2008-09-08 Cont ID  
Sent By mawillia Date 2008-09-08 Time 10:20 Rev Time 0.00
Received By mawillia Date 2008-09-08 Time 09:48 Sent To  
Notes
2008-09-08 10:20:34*****DENIED*****
  
 1. STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR
 DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241.
  
 2. THE PRROJECTED SCOPE OF WORK SHALL NOT HINDER OR
 INTEREFERE WITH ACCESS TO AND/OR EGRESS FROM OTHER
 FLOORS OF THE BUILDING.
  
 3. NFPA 101, LIFE SAFETY CODE, 2003 EDITION SHALL BE
 REFERENCED.
  
 4. BASED UPON OCCUPANCY CLASSIFICATION, PLEASE PROVIDE
 THE OCCUPANT LOAD FOR THE PROJECT SITE.
  
 5. PROVIDE A LIFE SAFETY PLAN SHOWING TRAVEL DISTANCE
 TO EXITS.
  
 6. PROVIDE A LAYOUT OF THE FIRE SPRINKLER HEADS FOR THE
 NEW NINTH FLOOR PLAN.
  
 7. SHOW THE LOCATION OF THE FIRE ALARM DEVICES FOR THE
 NEW NINTH FLOOR PLAN.
  
 8. SHOW THE LOCATION OF THE 2A:10BC FIRE
 EXTINGUISHER(S) WHICH SATIFY THE 75' TRAVEL DISTANCE.
  
 9. SPECIFY THE INTERIOR WALL FINISH MATERIALS IN TERMS
 OF CLASS A, CLASS B, OR CLASS C.
  
  
 TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE
 LETTER INDICATING WHERE ON THE APPROPIATE PLAN SHEET
 EACH ITEM WAS ADDRESSED
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop I INCOMING/PROCESSING
Rev No 8 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By jgomez Date 2009-05-12 Time 16:25 Sent To  
Notes
2009-05-12 16:28:54SENT TO C11.

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2009-04-29 Cont ID  
Sent By dpalmer Date 2009-04-29 Time 08:47 Rev Time 0.00
Received By dpalmer Date 2009-04-29 Time 08:47 Sent To  
Notes
2009-04-29 08:48:24TO C-16

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2009-02-18 Cont ID  
Sent By adarroug Date 2009-02-18 Time 10:19 Rev Time 0.00
Received By adarroug Date 2009-02-18 Time 10:19 Sent To  
Notes
2009-02-18 10:23:11TO "COMM" BD#11

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2008-12-16 Cont ID  
Sent By adarroug Date 2008-12-16 Time 12:37 Rev Time 0.00
Received By adarroug Date 2008-12-16 Time 12:37 Sent To E
Notes
2008-12-16 12:37:57TO "DPALMER" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2008-11-21 Cont ID  
Sent By adarroug Date 2008-11-21 Time 10:12 Rev Time 0.00
Received By adarroug Date 2008-11-21 Time 10:12 Sent To  
Notes
2008-11-21 10:12:54TO "COMM" BD#54

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2008-11-21 Cont ID  
Sent By adarroug Date 2008-11-21 Time 10:01 Rev Time 0.00
Received By adarroug Date 2008-11-21 Time 10:01 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-10-14 Cont ID  
Sent By adarroug Date 2008-10-14 Time 12:48 Rev Time 0.00
Received By adarroug Date 2008-10-14 Time 12:48 Sent To  
Notes
2008-10-14 12:51:25TO "COMM" BD#2

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-09-08 Cont ID  
Sent By mawillia Date 2008-09-08 Time 09:49 Rev Time 0.00
Received By mawillia Date 2008-08-15 Time 09:08 Sent To  
Notes
2008-08-15 09:19:11TO "COMM" BD#12

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2008-11-15 Cont ID  
Sent By rregueir Date 2008-11-15 Time 14:29 Rev Time 0.00
Received By rregueir Date 2008-11-15 Time 14:29 Sent To PC
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2008-08-27 Cont ID  
Sent By rregueir Date 2008-08-27 Time 15:06 Rev Time 0.00
Received By rregueir Date 2008-08-27 Time 14:29 Sent To  
Notes
2008-08-27 15:05:58REVIEW #: 1ST
 ACTION: DENIED
  
 FBC 2004 CODE FAMILY W/ 2007 SUPPLEMENTS
 FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH
  
 1. THIS IS AN EXISTING BUILDING. THE LEVEL OF
 ALTERATION IS NOT DECLARED ON THE PLANS. THE DESIGN
 PROFESSIONAL MUST ELECT ONE OR A COMBINATION OF LEVELS
 OF ALTERATION PURSUANT TO SECTIONS 303, 304 AND 305 OF
 THE FBCEB IN ACCORDANCE WITH FBCEB 301.5. THIS REVIEW
 IS BASED ON AN ASSUMED ALTERATION LEVEL 2.
  
 2. THERE ARE SEVERAL AREAS DEFINED BY NEW FULL-HEIGHT
 PARTITIONS IN THE WORK AREA. THIS CONSTITUTES A
 RECONFIGURATION OF SPACE. ALL RECONFIGURED SPACES
 INTENDED FOR OCCUPANCY IN ANY WORK AREA SHALL BE
 PROVIDED WITH NATURAL OR MECHANICAL VENTILATION OR
 EXHAUST IN ACCORDANCE WITH THE FBCEB 609.1. PROVIDE
 OUTSIDE AIR CALCULATIONS BASED ON FBCM TABLE 403.3 OR
 FBCM 403.4 SHOWING SPACE BY SPACE CALCULATIONS BASED ON
 OCCUPANCY CLASSIFICATION, OCCUPANT LOAD, CFM OF OUTSIDE
 AIR REQUIRED AND CFM OF OUTSIDE AIR PROVIDED.
  
 3. PAGE 3.0M SHOWS AT LEAST TWO DIFFERENT TYPES OF
 LINEAR DIFFUSERS IN THE NEW CEILING. THERE IS NO
 INDICATION ON PLANS AS TO THE DIFFERENCE BETWEEN THESE
 DIFFUSERS. PLEASE PROVIDE A SYMBOL LEGEND WHICH
 EXPLAINS ALL SYSTEMS OR COMPONENTS USED AS PART OF THE
 MECHANICAL SYSTEM IN ACCORDANCE WITH FBCM 603.1 AND
 FBCB 106.1.1.
  
 4. PAGE 3.0M: MECHANICAL SCOPE OF WORK NOTE #4
 INDICATES THAT NEW ADDITIONAL LINEAR DIFFUSERS AND FLEX
 DUCTS ARE PART OF THE SCOPE OF THIS WORK. HOWEVER, NO
 NEW DUCTS OR DIFFUSERS ARE INDICATED ON PLANS. PLEASE
 CLARIFY AND CLEARLY IDENTIFY THE SCOPE OF WORK ON THE
 PLANS IN ACCORDANCE WITH FBCM 603.1 AND FBCB 106.1.1.
  
 5. WITH NEW OR USED DIFFUSERS BEING CONNECTED TO DUCTS,
 PLEASE PROVIDE DETAIL FOR THIS DUCT TO TERMINAL FITTING
 CONNECTION DEMONSTRATING COMPLIANCE WITH THE SEALING
 AND MECHANICAL FASTENING REQUIREMENTS IN ACCORDANCE
 WITH ALL PORTIONS OF FBCM 603.5.6.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT:
 RONALD J. REGUEIRO
 561.805.6719
 [email protected]

Review Stop Z ZONING
Rev No 1 Status N Date 2008-08-25 Cont ID  
Sent By jroach Date 2008-08-25 Time 15:26 Rev Time 0.00
Received By jroach Date 2008-08-25 Time 15:26 Sent To  
Notes
***NONE***