| Plan Review Stops For Permit 08080305 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2008-08-25 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-08-25 |
Time |
15:37 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-08-25 |
Time |
15:01 |
Sent To |
PC |
|
| Notes |
| 2008-08-25 15:16:29 | BUILDING PROVISO: | | | TO BE IN PLACE AT C.O: | | | | | | PUBLIC POOLS | | | 424.1.3.1.9 ALL PUBLIC POOLS SHALL BE SURROUNDED BY A | | | MINIMUM 48" IN HEIGHT FENCE. A SELF LATCHING SELF | | | CLOSING LOCKABLE GATE OF 48" MINIMUM HEIGHT WITH THE | | | LATCH LOCATED NEAR THE TOP. SAFETY COVERS THAT COMPLY | | | WITH ASTM F 1346 DO NOT SATIFY THIS REQUIREMENT. | | | | | | 13-412.1ABC2.6.2 POOL COVERS. HEATED POOLS SHALL BE | | | EQUIPPED WITH A VAPOR RETARDANT POOL COVER ON OR AT THE | | | WATER SURFACE. POOLS HEATED TO MORE THAN 90 DEGREES | | | (F) | | | SHALL HAVE A POOL COVER WITH A MINIMUM INSULATION VALUE | | | OF R-12. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2008-09-15 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-09-15 |
Time |
13:20 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-09-15 |
Time |
12:26 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2008-08-15 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-08-15 |
Time |
08:41 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-08-14 |
Time |
15:41 |
Sent To |
Z |
|
| Notes |
| 2008-08-14 16:00:13 | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2005 | | | NEC, NFPA-72 2002, NFPA-101 2003, 2004 FBC AS AMENDED, | | | CHAPTER 1.AND FOUND NONCOMPLIANT WITH THE FOLLOWING:ALL | | | COMMENTS ARE FROM SHEET #4 OF 5. | | | | | | 1} INDICATE IF THE ELECTRICAL SERVICE SHOWN ON THE PLAN | | | IS NEW OR EXISTING. IF NEW INCLUDE AN AIC RATING, AND | | | LOCATE ALL SERVICE EQUIPMENT ON THE PLAN, METER | | | ENCLOSURE, DISCONNECTS AND PANELS, SO THAT COMPLIANCE | | | WITH ARTICLES 225 AND 230 CAN BE REVIEWED. PROVIDE A | | | RISER DIAGRAM WITH CONDUCTOR AND CONDUIT SIZE AND | | | TYPE. | | | | | | 2} INDICATE THE SIZE AND OCP FOR THE DISCONNECT SHOWN. | | | NOTE: THE FEEDERS FOR THE 150 AMP PANEL ARE #10 (30 | | | AMP?). | | | | | | 3} THE GROUNDING ELECTRODE CONDUCTOR MUST COMPLY WITH | | | 250.66. INDICATE SIZE AND COMPLIANCE WITH 250.52. | | | | | | 4} PROVIDE LOAD CALCULATIONS PER ARTICLE 220. | | | | | | 5} PROVIDE MANUFACTURERS SPECIFICATIONS FOR THE POOL | | | HEATER (TWO COPIES). | | | | | | 6} INDICATE COMPLIANCE WITH 680.26(C) EQUIPOTENTIAL | | | BONDING GRID BY DIAGRAM OR WITH A NOTE INDICATING HOW | | | IT WILL BE INSTALLED. SEE SENATE BILL 2836 APPROVED BY | | | THE GOVERNOR ON 6.19.07 FOR ALTERNATIVE METHOD. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-09-09 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-09-15 |
Time |
13:21 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-09-09 |
Time |
10:26 |
Sent To |
Z |
|
| Notes |
| 2008-09-09 10:26:39 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2008-08-25 |
Time |
|
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-08-14 |
Time |
09:52 |
Sent To |
|
|
| Notes |
| 2008-08-14 09:53:09 | TO "Z" BOX |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2008-08-14 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-09-15 |
Time |
13:21 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-08-14 |
Time |
14:18 |
Sent To |
E |
|
| Notes |
| 2008-08-14 14:19:26 | PASSED/PROVISO | | | | | | ALL WATER FROM THE FILTERS SHALL DRAIN TO SANITARY AND | | | ALL WATER FROM THE OVERFLOW SHALL DRAIN TO STORM. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2008-09-10 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2008-09-10 |
Time |
16:19 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2008-09-10 |
Time |
16:19 |
Sent To |
|
|
| Notes |
| 2008-09-10 16:23:32 | ***PROVISO*** | | | | | | 1) ENCLOSED PLANS SHALL BE UTILIZED ONLY FOR THE | | | LOCATION AND INSTALLATION OF THE POOL AND POOL DECK. | | | ALL OTHER WORK TO BE SUBMITTED UNDER SEPARATE PERMITS. | | | | | | 2) THE POOL SHALL BE COMPLETELY ENCLOSED BY A PERMANENT | | | FENCE (OR OTHER STRUCTURE) AND SHALL BE AT LEAST FOUR | | | (4) FEET IN HEIGHT. THE "REMOVABLE POOL FENCE" DOES NOT | | | SATISFY THIS REQUIREMENT....IT MUST BE PERMANENT. | | | ACCESS MUST BE THROUGH A BUILDING OR THROUGH A | | | SELF-CLOSING AND SELF-LATCHING GATE. THIS FENCE SHALL | | | BE SUBMITTED UNDER A SEPARATE PERMIT AND SHALL BE | | | INSTALLED PRIOR TO C.O. OF THE POOL. | | | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER, | | | AT (561) 822-1435. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2008-08-25 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2008-08-25 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2008-08-25 |
Time |
14:15 |
Sent To |
|
|
| Notes |
| 2008-08-25 14:28:15 | ***FAILED*** | | | | | | 1) TWO (2) COPIES OF A CURRENT/ACCURATE SURVEY SHALL BE | | | PROVIDED. | | | | | | 2) TWO (2) COPIES OF SITE PLAN SHALL BE PROVIDED | | | SHOWING THE LOCATION OF THE POOL AND POOL DECK RELATIVE | | | TO PROPERTY LINES AND OTHER IMPROVEMENTS.PLEASE | | | PROVIDE THE DIMENSIONS FROM THE POOL TO ALL PROPERTY | | | LINES. | | | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER, | | | AT (561) 822-1435. |
|
|