| Plan Review Stops For Permit 08080277 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2008-10-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-10-01 |
Time |
14:34 |
Rev Time |
1.77 |
| Received By |
jwitmer |
Date |
2008-10-01 |
Time |
14:34 |
Sent To |
ENG |
|
| Notes |
| 2008-10-01 14:52:56 | | | | ** BUILDING PLAN REVIEW** | | | PERMIT: 08080277 | | | ADD: 1505 N AUSTRALIAN AVE | | | CONT: BRADANNA INC. | | | TEL: (239)455-8891 | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | FOUNDATION REVIEW | | | ACTION: REVIEWED | | | | | | | | | BUILDING PROVISOS: | | | | | | 1) 105.13. SPECIAL FOUNDATION PERMIT | | | WHEN APPLICATION FOR A PERMIT TO ERECT OR ENLARGE A | | | BUILDING HAS BEEN FILED, & PENDING ISSUANCE OF SUCH | | | PERMIT, THE BUILDING OFFICIAL MAY, AT HIS/ HER | | | DISCRETION, ISSUE A SPECIAL PERMIT FOR THE FOUNDATION | | | ONLY, UPON WRITTEN REQUEST OF THE OWNER AND CONTRACTOR. | | | THE HOLDER OF SUCH A SPECIAL PERMIT IS PROCEEDING AT | | | HIS OR HER OWN RISK AND WITHOUT ASSURANCE THAT A PERMIT | | | FOR THE REMAINDER OF THE WORK WILL BE GRANTED | | | AND THAT CORRECTIONS WILL NOT BE REQUIRED IN ORDER TO | | | MEET THE PROVISIONS OF THE TECHNICAL CODE. | | | | | | 2) 109.3.10* IMPACT OF CONSTRUCTION. ALL CONSTRUCTION | | | ACTIVITY REGULATED BY THIS CODE SHALL BE PERFORMED IN A | | | MANNER SO AS NOT TO ADVERSELY IMPACT THE CONDITION OF | | | ADJACENT PROPERTY, UNLESS SUCH ACTIVITY IS PERMITTED TO | | | AFFECT SAID PROPERTY PURSUANT TO A CONSENT BY THE | | | APPLICABLE PROPERTY OWNER, UNDER TERMS & CONDITIONS | | | AGREEABLE TO THE APPLICABLE PROPERTY OWNER. THIS | | | INCLUDES BUT IS NOT LIMITED TO THE CONTROL OF DUST, | | | NOISE, WATER OR DRAINAGE RUN-OFF, DEBRIS, AND THE | | | STORAGE OF CONSTRUCTION MATERIALS. NEW CONSTRUCTION | | | ACTIVITY SHALL NOT ADVERSELY IMPACT HISTORIC SURFACE | | | WATER DRAINAGE FLOWS SERVING ADJACENT PROPERTIES, & MAY | | | REQUIRE SPECIAL DRAINAGE DESIGN COMPLYING WITH | | | ENGINEERING STANDARDS TO PRESERVE THE | | | POSITIVE PATTERNS OF THE AFFECTED SITES. ACCORDINGLY, | | | DEVELOPERS, CONTRACTORS, AND OWNERS OF ALL NEW | | | RESIDENTIAL DEVELOPMENT, INCLUDING ADDITIONS, POOLS, | | | PATIOS, DRIVEWAYS, DECKS, OR SIMILAR ITEMS, ON EXISTING | | | PROPERTIES RESULTING IN A DECREASE IN EXCESS OF 800SQ | | | FT OF PERMEABLE LAND AREA ON ANY PARCEL SHALL AS A | | | PERMIT CONDITION, PROVIDE A PROFESSIONALLY PREPARED | | | DRAINAGE PLAN CLEARLY INDICATING COMPLIANCE WITH THIS | | | PARAGRAPH. UPON COMPLETION OF THE IMPROVEMENT, A | | | CERTIFICATION FROM A LICENSED ENGINEER SHALL BE | | | SUBMITTED TO THE INSPECTOR IN ORDER TO RECEIVE APPROVAL | | | OF THE FINAL INSPECTION. | | | | | | 3) 109.3.10.1 HURRICANE PROTECTION. IT SHALL BE | | | UNLAWFUL FOR ANY PERSON TO ALLOW CONSTRUCTION RELATED | | | MATERIALS EQUIPMENT AND DEBRIS TO REMAIN LOOSE OR | | | OTHERWISE UNSECURED AT A CONSTRUCTION SITE FROM 24 HRS. | | | AFTER A HURRICANE WATCH HAS BEEN ISSUED UNTIL THE | | | HURRICANE WATCH OR WARNING HAS BEEN LIFTED. ALL SUCH | | | CONSTRUCTION MATERIALS, EQUIPMENT AND DEBRIS SHALL BE | | | EITHER REMOVED FROM THE CONSTRUCTION SITE OR SECURED IN | | | SUCH A MANNER AS TO MINIMIZE THE DANGER OF SUCH | | | CONSTRUCTION MATERIALS, EQUIPMENT AND DEBRIS CAUSING | | | DAMAGE TO PERSONS OR PROPERTY FROM HIGH WINDS. ANY | | | PERSONS WHO FAILS TO COMPLY TO REMOVE OR SECURE THE | | | CONSTRUCTION MATERIALS EQUIPMENT AND DEBRIS WITHIN 24 | | | HRS AFTER A HURRICANE WATCH HAS BEEN ISSUED SHALL BE | | | SUBJECT TO A FINE NOT TO EXCEED $500.00. IN ADDITION TO | | | THE ABOVE, A LICENSED CONTRACTOR WHO VIOLATES THIS | | | SECTION SHALL BE SUBJECT TO DISCIPLINE PURSUANT TO | | | SECTION 113 OF THIS CHAPTER. | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-08-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-08-27 |
Time |
10:24 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2008-08-27 |
Time |
10:24 |
Sent To |
|
|
| Notes |
| 2008-08-27 10:52:54 | BUILDING PLAN REVIEW | | | PERMIT: 08080277 | | | ADD: 1505 N AUSTRALIAN AVE | | | CONT: (PLAN REVIEW) | | | | | | TEL: (561)###-#### | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW | | | ACTION: DENIED | | | | | | NOTE : PLANS APPEAR TO BE CODE COMPLIANT, BUT NO PERMIT | | | APPLICATION HAS BEEN MADE WITH CONTRACTOR SIGNED ON NOR | | | CAN RADON FEES BE ASSESSED UNTIL A PERMIT APPLICATION | | | HAS BEEN MADE. | | | | | | NOTE: MISSING ELECTRICAL SHEET FOR BONDING REQUIREMENTS | | | WILL BE ADDRESSED BY THE ELECTRICAL PLAN REVIEWER.. | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2008-10-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-10-20 |
Time |
10:26 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-10-20 |
Time |
10:26 |
Sent To |
PC |
|
| Notes |
| 2008-10-20 10:26:51 | ** DENIED REVISION** | | | | | | | | | | | | | | | 1) NOTE: PLEASE SUBMIT THE ELECTRICAL TEMPORARY SERVICE | | | PLANS UNDER AN ELECTRICAL PERMIT APPLICATION. THIS CAN | | | NOT BE A REVISION TO THE BUILDING CONTRACTOR FOUNDATION | | | PERMIT. | | | | | | 2) NOTE: PLEASE SEE 250.66 FOR THE CORRECT SIZING OF | | | THE GROUNDING ELECTRODE CONDUCTOR. | | | | | | 3) NOTE: PLEASE COMPLETE RISER WITH ALL CONDUCTORS | | | INCLUDING ALL CONDUCTORS FROM WHAT APPEARS TO BE A | | | GUTTER. THE BOX ABOVE MAY OR MAY NOT BE A GUTTER?? | | | | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANOR PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2008-09-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-09-30 |
Time |
13:27 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-09-30 |
Time |
13:27 |
Sent To |
|
|
| Notes |
| 2008-09-30 13:28:25 | ** FOR INSTALLATION OF GROUNDING ELECTRODE SYSTEM AND | | | FOUNDATION/SLAB CONDUITS ONLY. | | | | | | ** ELECTRICAL SUB PERMIT REQUIRED ONCE THIS PERMIT IS | | | ISSUED FOR ELECTRICAL SCOPE OF WORK AS NOTED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2008-08-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-08-27 |
Time |
16:48 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-08-27 |
Time |
16:48 |
Sent To |
|
|
| Notes |
| 2008-08-27 16:48:22 | **DENIED** | | | | | | | | | | | | 1) NOTE: PLANS ONLY SUBMITTED FOR PLAN REVIEW AND NOT | | | FOR PERMIT APPLICATION. | | | | | | 2) NOTE: PLEASE SUBMIT ALL ELECTRICAL WHICH MAY BE PART | | | OF THE SLAB/FOUNDATION. PLEASE SEE 250.50 AS THE | | | MINIMUM IS REQUIRED FOR THE GROUNDING ELECTRODE SYSTEM. | | | PLEASE SUBMIT THE GROUNDING ELECTRODE RISER FOR | | | FOUNDATION WORK. | | | PLEASE SUBMIT CONDUIT LAYOUT AND SIZES FOR ANY PROPOSED | | | WORK WHICH MAY BE PART OF FOUNDATION. | | | | | | | | | | | | | | | **IMPORTANT** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | | TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANOR PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2008-10-02 |
|
|
Cont ID |
|
| Sent By |
dlauderm |
Date |
2008-10-02 |
Time |
15:33 |
Rev Time |
0.00 |
| Received By |
dlauderm |
Date |
2008-10-01 |
Time |
11:40 |
Sent To |
|
|
| Notes |
| 2008-10-02 15:34:54 | PASSED. ALL ITEMS IN PREVIOUS REVIEWS HAVE BEEN MET. | | | DSL |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2008-08-27 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2008-08-27 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2008-08-27 |
Time |
14:21 |
Sent To |
|
|
| Notes |
| 2008-08-27 14:37:38 | FAILED FOR FOLLOWING REASONS: | | | | | | 1. PLEASE SHOW ON DRAWINGS THETURBIDITY BARRIER ON | | | NORTH SIDE OF THE SITE,ALONG THE CANAL.ALSO PLEASE | | | SHOW SILT FENCE ON EAST SIDE OF SITE. | | | | | | 2. PLEASE PROVIDE A COPY OF BOND FOR ORDINANCE NO. | | | 4060-07: | | | | | | ALL DEMOLITION AND NEW CONSTRUCTION PERMITS, WITH | | | EXCEPTION OF SINGLE FAMILY, DUPLEX AND ACCESSORY | | | APARTMENT, SHALL POST BONDS OR DEPOSITS FOR THE | | | FOLLOWING: | | | | | | 1. EROSION CONTROL, AND | | | 2. LAND STABILIZATION | | | | | | THE AMOUNT OF THE EROSION CONTROL AND LAND | | | STABILIZATION BONDS SHALL BE DETERMINED BY THE ENGINEER | | | OF RECORD USING THE CURRENT CITY COST SCHEDULE AND | | | VERIFIED BY THE CITY'S ENGINEERING SERVICES DEPT. | | | PLEASE CONTACT BRIAN MOREE, ENG SERVICES CONSTRUCTION | | | SUPERVISOR, AT 561- 494 -1040 FOR MORE INFORMATION. | | | | | | UPON VERTICAL CONSTRUCTION COMMENCEMENT, PAYMENT IN | | | FULL OF ALL APPLICABLE FEES, AND COMPLIANCE WITH ALL | | | TERMS AND CONDITIONS OF ANY POSTED BOND, THE PERMITTEE | | | MAY REQUEST RELEASE OF THE BONDS OR DEPOSITS. | | | | | | A COPY OF ORDINANCE NO. 4060-07 MAY BE OBTAINED FROM | | | THE CITY CLERK'S OFFICE LOCATED ON THE FIRST FLOOR. | | | | | | 3. PLEASE SHOW ON DRAWINGSDUMPSTER & ITS ENCLOSURE | | | DETAILS PER CITY OF WPB, &LOCATION ON DWG, LOCATION | | | MUST BE ACCESSIBLE FOR PICKUP TRUCK. | | | | | | 4. PLEASE SHOW ON CALCULATION THAT YOU HAVE CONSIDERED | | | FLOOD ZONE AREA, & 5,10, 25, 100 YEAR FLOOD CRITERIA | | | AND CROWN OF THE ROAD WHEN YOU DETERMINE THE FIRST | | | FLOOR ELEVATION. FIRST FLOOR ELEVATION SHOULD BE | | | ATLEAST 1 FOOT HIGHER THAN HIGHEST CROWN OF THE ROAD. | | | STORM WATER CALS MUST BE APPROVED FROM 1000 45TH ST | | | ENGINEERING. | | | | | | 5. PLEASE SHOW ON DRAINAGE DRAWINGTHE SITE AREA, | | | GREEN, LAKE,PARKING AREA, IMPERVIOUS,PERVIOUS AREAYOU | | | ARE DEVELOPING FOR THIS PROJECT . PLEASEMAKE SURE | | | THESE AREAS SHOWN ON DRAINAGE DRAWINGS MUST MATCH WITH | | | AND USED IN STORM WATER QUALITY CALCULATIONS. PLEASE | | | PROVIDE A COPY OF THESE CALCULATIONS AFTER THEY ARE | | | APPROVED FROM 1000 45TH ST ENGINEERING. | | | | | | 6. PLEASE SHOW ALL STORM WATER PIPES AROUND YOUR SITE | | | SO, WE CANSEE THE LAYOUT OF STORM WATER PIPES FROM | | | ALL OTHER STORM WATER PIPES. PLEASE SHOW DETAIL OF THE | | | CONTROL STRUCTURESWITH ELEVATIONS, NOTCHES, BLEEDING | | | ELEVATION, ETC ON DRAWINGS, CALCULATION FOR | | | EXFILTRATION TRENCHES, PLEASE SHOW DRY DETENTION/WET | | | DETENTION AREAS IN STORM WATER CALS IF YOU HAVE ALL | | | THESE. PLEASE RESUBMIT GEO-TECH REPORT AND ALL | | | ENVRONMENTAL REPORT. | | | | | | 7. ALSO PLEASE SHOW ALL CATCH BASINS NEAREST,AROUND | | | YOUR SITE FOR STORM WATER DRAIN SO YOUR SITE DO NOT GET | | | FLOODED AND HAVE ENOUGH DRAINS. | | | | | | 8. PLEASE PROVIDE A COPY OF SFWMD PERMIT,, GEO-TECH | | | REPORT&STORM WATER QUALITY CALCULATIONS AFTER THEY | | | ARE APPROVED FROM 100045TH STREET ENGINEERING | | | SERVICES BEFORE WE ISSUE A PERMIT. | | | | | | | | | PLEASE RESPOND EACH ITEM IN DETAIL WITH DRAWING | | | REFERENCE #TO EXPEDITE YOUR PERMITTING PROCESS | | | | | | RASIK CHOKSHI805-6723 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2008-09-30 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-09-30 |
Time |
14:29 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-09-30 |
Time |
14:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2008-08-29 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-08-29 |
Time |
15:57 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-08-29 |
Time |
15:56 |
Sent To |
|
|
| Notes |
| 2008-08-29 16:00:32 | FOR PLAN REVIEW ONLY | | | | | | FOUNDATION | | | | | | ***DENIED*** | | | | | | 1) NO FIRE LINES PERMITTED BENEATH FOUNDATION, SLAB | | | ETC. | | | | | | 2) CODE REFERENCE #4 SHOULD READ FLORIDA FIRE | | | PREVENTION CODE, 2004. NFPA 101, 2003 IS CORRECTLY | | | IDENTIFIED IN NOTE #3. | | | | | | | | | MIKE WENNERGREN, ASSISTANT FIRE PREVENTION | | | FIRE PLAN REVIEW | | | FIRE PREVENTION (561) 804-4756 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2008-10-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-10-15 |
Time |
09:55 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-10-15 |
Time |
09:55 |
Sent To |
E |
|
| Notes |
| 2008-10-15 09:55:35 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-10-08 |
|
|
Cont ID |
|
| Sent By |
mmiller |
Date |
2008-10-08 |
Time |
14:46 |
Rev Time |
0.00 |
| Received By |
mmiller |
Date |
2008-10-08 |
Time |
14:46 |
Sent To |
P |
|
| Notes |
| 2008-10-08 14:46:38 | ROUTED TO KEN STEVEN'S DESK MMILLER |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-09-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-09-26 |
Time |
09:06 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-09-26 |
Time |
09:06 |
Sent To |
|
|
| Notes |
| 2008-09-26 09:17:03 | TO "COMM" BD#25/PLANS ON RACK/LARGE FOLDED | | | PLANS--EXPEDITED-- |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-08-29 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-08-29 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-08-13 |
Time |
11:13 |
Sent To |
|
|
| Notes |
| 2008-08-13 11:13:22 | TO "COMM" BD#16--EXPEDITED-- |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2008-10-08 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-10-08 |
Time |
16:50 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-10-08 |
Time |
16:50 |
Sent To |
|
|
| Notes |
| 2008-10-08 16:51:19 | PLUMBING REVISIONS OK -- SHTS P-2, P-4 & P-5 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2008-08-14 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-08-14 |
Time |
12:04 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-08-14 |
Time |
12:04 |
Sent To |
|
|
| Notes |
| 2008-08-14 12:05:08 | NO PLUMBING PLANS SUBMITTED--CONTRACTOR TO PROCEED | | | AT OWN RISK |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2008-08-15 |
|
|
Cont ID |
|
| Sent By |
adavila |
Date |
2008-08-15 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
adavila |
Date |
2008-08-15 |
Time |
11:16 |
Sent To |
|
|
| Notes |
| 2008-08-15 11:17:02 | PER ERIC SCHNEIDER, PRINCIPAL PLANNER. | | | |
|
|