Plan Review Details - Permit 08080031
Plan Review Stops For Permit 08080031
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2008-12-01 Cont ID  
Sent By jwitmer Date 2008-12-01 Time 16:54 Rev Time 0.77
Received By jwitmer Date 2008-12-01 Time 16:54 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2008-10-22 Cont ID  
Sent By jwitmer Date 2008-10-22 Time 12:47 Rev Time 3.33
Received By jwitmer Date 2008-10-22 Time 12:47 Sent To  
Notes
2008-10-22 13:00:03BUILDING PLAN REVIEW
 PERMIT: 08080031
 ADD: 225 CLEMATIS ST.
 CONT: PLAZA CONSTRUCTION
 TEL: (561) 271-5297
  
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 WED. OCT.22, 08
 2ND REVIEW
 ACTION: DENIED
  
 1A-C) COMPLIED.
  
 1D ) INFORMATIONAL FL S S 713.13 NOTICE OF
 COMMENCEMENT, TO BE FILED WITH THE CLERK OF THE COURT.
 NOTE: 713.13(2) IF THE WORK DESCRIBED IN THE NOTICE OF
 COMMENCEMENT IS NOT ACTUALLY COMMENCED WITHIN 90 DAYS
 AFTER THE RECORDING THEREOF, SUCH NOTICE IS NULL &
 VOID. NOTE: 713.13(6) THE POSTING OF THE NOTICE OF
 COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE THE FIRST
 INSPECTION.
  
 1E) COMPLIED.
  
 2) PLEASE NOTE THIS IS A CONTINUATION OF A FOUR STORY
 BUILDING WHICH IS REGULATED BY FL S S 553.71(7)
 REQUIRING SPECIAL INSPECTION BY THRESHOLD INSPECTORS
 AND THRESHOLD INSPECTION PLAN.
  
 THRESHOLD INSPECTION PLAN FL S. S. 553.71(7) "
 THRESHOLD BUILDING" MEANING ANY BUILDING WHICH IS
 GREATER THAN (3) STORIES OR 50 FT IN HEIGHT, OR WHICH
 HAS AN ASSEMBLY OCCUPANCY CLASSIFICATION AS DENIED IN
 THE FLORIDA BUILDING CODE WHICH EXCEEDS 5,000 SQ FT IN
 AREA AND AN OCCUPANT CONTENT OF GREATER THAN 500
 PERSONS.
  
 2A) COMPLIED
  
 2B) THRESHOLD INSPECTOR: WPB AMENDMENT 105.13.6. W.P.B.
 CONSTRUCTION SERVICES DEPARTMENT REQUEST FOR THRESHOLD
 BUILDINGS A SPECIAL INSPECTOR AS REQUIRED BY FL S S
 553.79(5) FLORIDA STATUTES TO THE MINIMUM INSPECTIONS
 REQUIRED BY THIS CODE. CONTACT KEN CONRAD MANAGER OF
 THE SPECIAL INSPECTOR PROGRAM AT (561)805-6666 FOR
 FURTHER INFORMATION BEFORE
 THE PERMIT MAY BE ISSUED.
  
 2C) COMPLIED.
  
 3) COMPLIED.
  
 4BUILDING PROVISO: WILL NEED MANUFACTURES SPEC FOR
 LIFT. SHEET A2.2 INDICATES A NEW STAIR WAY NEXT TO THE
 ELEVATOR LOBBY. THE EXISTING BUILDING CODE 606.1 A
 BUILDING OR ELEMENT THAT IS ALTERED SHALL COMPLY WITH
 CHAPTER 11 OF THE FLORIDA BUILDING CODE,
 BUILDING.11-4.1.6(1) (B) AND 11-4.1.6 (2) (A) (II) BOTH
 INDICATE THAT THE LOWER OFFICE LEVEL NEEDS TO BE ON AN
 ACCESSIBLE ROUTE.
  
 5) COMPLIED.
  
 6) COMPLIED.
  
 7)COMPLIED.
 NEW COMMENT:
 8) DEALS WITH THE ENERGY CALCULATIONS PROVIDED,
 SUBMITTED WAS METHOD "A" THE WHOLE BUILDING METHOD,
 NOTE THE AREA INDICATES 463 SQ FT. THIS IS NOT THE
 WHOLE 4 STORY BUILDING. METHOD C OR JUST THE
 PRESCRIPTIVE METHOD IS ALL THAT WOULD BE NEEDED. PLEASE
 REVIEW 13-400.0 C PRESCRIPTIVE ENVELOPE METHOD.
 A) NOTE ROOF CALCULATION SUBMITTED IS FOR A METAL
 BUILDING WITH BATT INSULATION PLEASE CORRECT.
 B) DOORS INDICATES DOOR FOR THE WEST WALL BUT NOT THE
 DOOR BEING REPLACED ON THE SOUTH WALL.
 C) FLOORS -ARE INDICATED AS ON THE 1ST FLOOR WITH 1 FT
 OF SOIL,AND CARPET AND PADDING BUT WORK IS ALSO BEING
 DONE ON THE SECOND FLOOR
  
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)659-8026
 E-MAIL: [email protected]
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-08-14 Cont ID  
Sent By jwitmer Date 2008-08-14 Time 10:08 Rev Time 3.33
Received By jwitmer Date 2008-08-14 Time 08:59 Sent To  
Notes
2008-08-14 09:46:44BUILDING PLAN REVIEW
 PERMIT: 08080031
 ADD: 225 CLEMATIS ST.
 CONT: PLAZA CONSTRUCTION
 TEL: (561) 271-5297
  
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 AUGUST 14,2008
 1ST REVIEW
 ACTION: DENIED
  
 1A) INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE
 INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 1B) INFORMATIONAL: PLEASE SUBMIT 2 OF ALL SURVEYS,
 PLANS, REPORTS, REVISIONS , PRODUCT APPROVALS AND OR
 SUBMITTALS FOR REVIEW FOR PERMIT. IF YOUR PROJECT WILL
 REQUIRE A RESIDENT INSPECTOR OR IF YOUR PROJECT IS A
 THRESHOLD BUILDING REQUIRING A THRESHOLD INSPECTOR THEN
 (3) THREE SETS OF ALL SAID DOCUMENTS WILL BE REQUIRED
 FOR PERMIT ISSUANCE. 106.1* /2004 SUBMITTAL DOCUMENTS
 WEST PALM BEACH ADMINISTRATIVE CODE.
  
 1C) INFORMATIONAL 106.1.1* W.P.B. ADMINISTRATIVE
 CODE/2004 DRAWINGS & SPECIFICATIONS SHALL CONTAIN
 INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, AS TO
 THE QUALITY OF MATERIALS, WHERE QUALITY IS ESSENTIAL TO
 CONFORMITY WITH THE TECHNICAL CODES. SUCH INFORMATION
 SHALL BE SPECIFIC TO THE TECHNICAL CODES "SHALL NOT BE
 CITED AS A WHOLE OR IN PART, NOR THE TERM "LEGAL" OR
 ITS EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC
 INFORMATION". CONSTRUCTION DOCUMENTS SHALL BE
 SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND
 EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT
 WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL.
  
 1D ) INFORMATIONAL FL S S 713.13 NOTICE OF
 COMMENCEMENT, TO BE FILED WITH THE CLERK OF THE COURT.
 NOTE: 713.13(2) IF THE WORK DESCRIBED IN THE NOTICE OF
 COMMENCEMENT IS NOT ACTUALLY COMMENCED WITHIN 90 DAYS
 AFTER THE RECORDING THEREOF, SUCH NOTICE IS NULL &
 VOID. NOTE: 713.13(6) THE POSTING OF THE NOTICE OF
 COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE THE FIRST
 INSPECTION.
  
 1E) INFORMATIONAL: PLANS SUBMITTED FOR PERMIT (FIRST
 TIME REVIEW) AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO
 THE 2004 FBC BUILDING WITH THE 2007 SUPPLEMENTS.
  
 2) PLEASE NOTE THIS IS A CONTINUATION OF A FOUR STORY
 BUILDING WHICH IS REGULATED BY FL S S 553.71(7)
 REQUIRING SPECIAL INSPECTION BY THRESHOLD INSPECTORS
 AND THRESHOLD INSPECTION PLAN.
  
 THRESHOLD INSPECTION PLAN FL S. S. 553.71(7) "
 THRESHOLD BUILDING" MEANING ANY BUILDING WHICH IS
 GREATER THAN (3) STORIES OR 50 FT IN HEIGHT, OR WHICH
 HAS AN ASSEMBLY OCCUPANCY CLASSIFICATION AS DENIED IN
 THE FLORIDA BUILDING CODE WHICH EXCEEDS 5,000 SQ FT IN
 AREA AND AN OCCUPANT CONTENT OF GREATER THAN 500
 PERSONS.
  
 2A) 105.13.1 THE ENFORCING AGENCY SHALL REQUIRE A
 SPECIAL INSPECTOR TO PERFORM STRUCTURAL INSPECTIONS ON
 A THRESHOLD BUILDING PURSUANT TO A STRUCTURAL
 INSPECTION PLAN PREPARED BY THE ENGINEER OF RECORD. THE
 STRUCTURAL INSPECTION PLAN MUST BE SUBMITTED TO THE
 ENFORCING AGENCY PRIOR TO THE ISSUANCE OF A BUILDING
 PERMIT FOR THE CONSTRUCTION OF A THRESHOLD BUILDING.
 THE PURPOSE OF THE STRUCTURAL INSPECTION PLAN IS TO
 PROVIDE SPECIFIC INSPECTION PROCEDURES AND SCHEDULES SO
 THAT THE BUILDING CAN BE ADEQUATELY INSPECTED FOR
 COMPLIANCE WITH THE PERMITTED DOCUMENTS.
  
 2B) THRESHOLD INSPECTOR: WPB AMENDMENT 105.13.6. W.P.B.
 CONSTRUCTION SERVICES DEPARTMENT REQUEST FOR THRESHOLD
 BUILDINGS A SPECIAL INSPECTOR AS REQUIRED BY FL S S
 553.79(5) FLORIDA STATUTES TO THE MINIMUM INSPECTIONS
 REQUIRED BY THIS CODE. CONTACT KEN CONRAD MANAGER OF
 THE SPECIAL INSPECTOR PROGRAM AT (561)805-6666 FOR
 FURTHER INFORMATION BEFORE
 THE PERMIT MAY BE ISSUED.
  
 2C) THRESHOLD BLDG, REQUIRED STATEMENT: W.P.B.
 AMENDMENT 105.13.4.4 ALL PLANS FOR THE BUILDING WHICH
 ARE REQUIRED TO BE SIGNED AND SEALED BY THE ARCHITECT
 OR ENGINEER OF RECORD CONTAIN A STATEMENT THAT, TO THE
 BEST OF THE ARCHITECT'S PR ENGINEER'S KNOWLEDGE, THE
 PLANS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE
 FIRE-SAFETY STANDARDS AS DETERMINED BY THE LOCAL
 AUTHORITY IN
 ACCORDANCE WITH THIS SECTION AND 633 FLORIDA STATUTE.
  
 3) DISCREPANCY, SHEET S-1 INDICATES AT THE CENTER
 BOTTOM OF THE SHEET A FIRST FLOOR FOUNDATION PLAN WITH
 DOUBLE DOORS, A-2.1 DOES NOT INDICATE DOUBLE DOORS BUT
 A NEW SINGLE DOOR IN THE FULL FLOOR PLAN, ENTRY STAIR
 AND ENCLOSURE IN DETAIL ARE COVERED UNDER PERMIT #
 07120350 223 CLEMATIS ST CAN NOT BE PART OF THIS
 PERMIT. PERMIT# 07120350 CONTRACTOR IS CASTLE
 FLORIDA.
  
 4) SHEET A2.2 INDICATES A NEW STAIR WAY NEXT TO THE
 ELEVATOR LOBBY. THE EXISTING BUILDING CODE 606.1 A
 BUILDING OR ELEMENT THAT IS ALTERED SHALL COMPLY WITH
 CHAPTER 11 OF THE FLORIDA BUILDING CODE,
 BUILDING.11-4.1.6(1) (B) AND 11-4.1.6 (2) (A) (II) BOTH
 INDICATE THAT THE LOWER OFFICE LEVEL NEEDS TO BE ON AN
 ACCESSIBLE ROUTE. THE IMPROVEMENTS TO THE ELEVATOR CAN
 NOT BE USED AS PART OF THE DISPROPORTIONATE COST OF THE
 PROJECT. I'VE SPOKEN WITH THE BUILDING OFFICIAL ON THIS
 MATTER AND THESTATE MAY PROVIDE A WAIVER, THE FORMS FOR
 WAIVER FROM THE STATE ARE ON LINE UNDER
 WWW.FLORIDABUILDING .ORG, CLICK ON FLORIDA BUILDING
 CODE, CLICK ON CHAPTER 11, AT THE BACK OF THE CHAPTER
 IS WHERE THE APPLICATION FOR WAIVER IS LOCATED.
  
 5) SHEET A2.2 THE BACK CORRIDOR THAT LEADS TO THE
 VERTICAL EXIT IS MISSING THE EGRESS DOOR FROM THE
 NIGHTCLUB TO THE EAST. ADDITIONAL INFORMATION REQUIRED
 106.1.2.
  
 6) SHEET A-2.2 DETAIL PARTITION LEGEND WALL TYPE # 7
 INDICATES A WP 7095 BUT THE TI-1.1 DOES NOT PROVIDE THE
 ASSEMBLY AS OTHER WALL ASSEMBLIES ARE PROVIDE. PLEASE
 PROVIDE THE WP 7095 ASSEMBLY INFORMATION. 707.4 &
 707.5.
  
 7) SHEET A-2.2 JUST EAST OF THE NEW RESTROOM
 THEREAPPEARS TO BE ANOTHER SHAFT BUT THE SHAFT WALL
 DESIGNATION IS NOT PROVIDED. 707.4 & 707.5.
  
 A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A
 RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)659-8026
 E-MAIL: [email protected]
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2008-12-02 Cont ID  
Sent By dpalmer Date 2008-12-02 Time 08:46 Rev Time 0.00
Received By dpalmer Date 2008-12-01 Time 18:03 Sent To  
Notes
2008-12-02 08:46:49 
 1) NOTE: NEW FORM *C* SUBMITTED WITH ATTACHED LIGHTING
 PERFORMANCE FROM TABLE *B* ARE NOT APPLICABLE. MAY NOT
 USE TWO SEPARATE METHODS.
 PLANS SHOW LIGHTING COMPLIANCE BY THE USE OF TABLE *B*
 ON SHEET E-2. THE FORMS IN PACKAGE WILL NOT BE PART OF
 THE PERMITTED PLANS OR DOCUMENTS AND WILL BE RE-TURNED.
 IF THERE ARE QUESTIONS PLEASE CALL.
  
 2) RISER HAS OLD METER BEING REMOVED, NEW CT METERING
 REQUIRED PER FPL SERVICE STANDARDS.
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2008-10-30 Cont ID  
Sent By dpalmer Date 2008-10-30 Time 11:30 Rev Time 0.00
Received By dpalmer Date 2008-10-30 Time 11:30 Sent To  
Notes
2008-10-30 11:30:39 
  
  
  
 ** DENIED 2ND REVIEW**
  
  
 ** THERE ARE SOME NOTES FROM PREVIOUS REVIEW WHICH ARE
 STILL IN NEED OF BEING ADDRESSED.
 ** SPOKE TO TOM FROM HENZ ENGINEERING AND HE IS AWARE
 OF COMMENTS BELOW. PLANS ARE COMING BACK FOR COMMENTS
 FROM OTHER TRADES PLEASE ADDRESS AT THIS TIME.
  
  
  
  
 1) NOTE: PLEASE PROVIDE LIGHTING DENSITIES PER
 13-415.2, 13-415.2.ABC.1.1, .1.2
  
 2) NOTE: PLEASE PROVIDE CONTROLS FOR NON-24HR LIGHTING
 PER 13-415.1.ABC.1.1, .1.2.
  
 3) NOTE: PLEASE INDICATE MAIN AS DISCUSSED OVER THE
 PHONE AHEAD OF 600AMP METER.
 230.2E.
  
 4) NOTE: PLEASE MAKE NOTE FOR EQUIPMENT GROUNDING PATH
 ON THE LOAD SIDE OF MAIN. AS THE PLANS ARE INDICATING
 RMC, THEN THE CONTRACTOR MUST USED NEW LISTED FITTINGS
 FOR EQUIPMENT GROUNDING.
 PLACE NOTE ON PLANS FOR WORDS TO THAT AFFECT.
 250.122,250.110,250.24.
  
 **IMPORTANT**
 ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP
 FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE
 ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING.
 DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS.
 PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY
 ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS,
 SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED
 INTO TWO SETS/FOLDERS/BINDERS ETC.
 PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS
 SHOULD BE SUBMITTED FOR REFERENCE.
 THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID
 ANY DELAYS.
  
  
 IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT
 TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO
 CONTACT THIS REVIEWER.
  
  
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2008-08-13 Cont ID  
Sent By dpalmer Date 2008-08-13 Time 13:19 Rev Time 0.00
Received By dpalmer Date 2008-08-13 Time 13:18 Sent To  
Notes
2008-08-13 13:19:12** DENIED PLANS.**
  
  
 1) NOTE: PLEASE SEE 620.23 AS THE LIGHTING IN THE
 ELEVATOR EQUIPMENT ROOM IS REQUIRED TO BE ON A
 DEDICATED CIRCUIT. PLANS SHOW THE LIGHTING BEING
 CIRCUITED TO HALLWAY LIGHTING WHICH IS NOT PERMITTED.
  
 2) NOTE: PLEASE SEE NFPA-101 7.8.1.3 AS THE EGRESS
 LIGHTING IN CORRIDOR NEED TO MEET CONTROLS PER
 7.8.1.2.2 AND FBC 1006.1.2
 THESE DEVICES SHALL BE FAIL SAFE ON.
  
 3) NOTE: PLEASE SEE 700.16 AS BATTERY BACK UP LIGHTING
 OF SOME KIND IS REQUIRED IN THE ELEVATOR EQUIPMENT
 ROOM.
  
 4) NOTE: PLEASE SEE 13-415.2, 13-415.2.ABC.1.1, .1.2
 AND SUBMIT LIGHTING PERFORMANCE CALCULATIONS FOR NEW
 AREAS.
 PLEASE SUBMIT A COMPLETED FIXTURE SCHEDULE SHOWING EACH
 FIXTURE TYPE, WATTAGE, MANUFACTURE ETC.
  
 5) NOTE: AS NOTED ABOVE PLEASE SEE 13-415.1.ABC.1.1,
 .1.2 FOR REQUIRED AUTOMATED LIGHTING CONTROLS FOR NEW
 DEVICES. SEE NOTE #2 ABOVE WITH RESPECT TO DEVICES SUCH
 AS OCCUPANCY SENSORS.
  
 6) NOTE: PLEASE SHOW THE LIGHTING LEVELS FOR EGRESS
 UNDER BOTH CONDITIONS OF NORMAL AND EMERGENCY.
 NFPA-101 7.8.1.3, 7.9.2.1, .2.2
  
 7) NOTE:PLEASE SEE FBC 11-4.28.1, .2 AND .3 FOR ADA
 REQUIREMENTS OF HORNS, STROBE ETC.
 PLANS MUST SHOW LOCATIONSAND MINIMUM LEVELS OF
 DEVICES.
  
  
  
 **IMPORTANT**
 ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP
 FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE
 ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING.
 DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS.
 PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY
 ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS,
 SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO
 TWO SETS/FOLDERS/BINDERS ETC.
 PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS
 SHOULD BE SUBMITTED FOR REFERENCE.
 THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID
 ANY DELAYS.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2008-12-08 Cont ID  
Sent By mawillia Date 2008-12-08 Time 15:46 Rev Time 0.00
Received By mawillia Date 2008-12-08 Time 15:28 Sent To  
Notes
2008-12-08 15:42:46*****APPROVED*****
  
  
 PLAN SHEETS A-0.1, A-5.1, & E-2 WERE STAMPED,
 INITIALED, AND DATED; SHEETS A-2.1 & A2.2 WERE
 PREVIOUSLY STAMPED BY WENNERGREN ON 10/30/08.

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2008-10-30 Cont ID  
Sent By mwennerg Date 2008-10-30 Time 15:32 Rev Time 0.00
Received By mwennerg Date 2008-10-30 Time 15:32 Sent To  
Notes
2008-10-30 15:33:01SEPARATE SHOP DRAWINGS AND PERMITS REQUIRED FOR FIRE
 ALARM AND FIRE SPRINKLER REMODEL IF APPLICABLE.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2008-09-04 Cont ID  
Sent By mwennerg Date 2008-09-04 Time 15:27 Rev Time 0.00
Received By mwennerg Date 2008-09-04 Time 15:27 Sent To  
Notes
2008-09-04 15:43:39***DENIED***
  
 1) IN ADDITION TO APPLICABLE BUILDING CODES, LIFE
 SAFETY TO COMPLY WITH NFPA 101, 2003.
  
 2) CONSTRUCTION, ALTERATION AND DEMOLITION TO COMPLY
 WITH THE REQUIREMENTS OF NFPA 241.
  
 3) ELEVATOR SHALL COMPLY WITH ASME/ANSI A17.1.
  
 4) SITE SHALL BE CLEANED DAILY OR MORE FREQUENT AS
 NECESSARY TO PREVENT THE BUILD UP OF CONSTRUCTION
 RELATED DEBRIS.
  
 5) CORRECT NFPA REFERENCE ON HARDWARE SCHEDULE; SHEET
 A-2.1 TO NFPA 101, SEC. 7.2.1.5.
  
 6) PLEASE VERIFY IF SCOPE OF WORK INVOLVES (2) HOUR
 RATED WALL ASSEMBLIES. THE DOOR SCHEDULE DOES NOT
 INDICATE (1 1/2 ) HOUR RATED DOORS.
  
 7) PROVIDE PRESCRIPTIVE STRENGTH REQUIREMENT FOR WALLS
 AND CEILING.
  
  
 MIKE WENNERGREN, ASSISTANT FIRE MARSHAL
 FIRE PLAN REVIEW
 FIRE PREVENTION (561) 804-4756

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2008-11-13 Cont ID  
Sent By adarroug Date 2008-11-13 Time 15:04 Rev Time 0.00
Received By adarroug Date 2008-11-13 Time 15:04 Sent To  
Notes
2008-11-13 15:11:32TO "COMM" BD#25

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-10-07 Cont ID  
Sent By adarroug Date 2008-10-07 Time 16:30 Rev Time 0.00
Received By adarroug Date 2008-10-07 Time 16:30 Sent To  
Notes
2008-10-07 16:35:18TO "COMM" BD#15

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-09-04 Cont ID  
Sent By mwennerg Date 2008-09-04 Time 15:45 Rev Time 0.00
Received By mwennerg Date 2008-08-04 Time 10:07 Sent To  
Notes
2008-08-04 10:07:27TO "COMM" BD#41

Review Stop M MECHANICAL (A/C)
Rev No 3 Status N Date 2008-12-06 Cont ID  
Sent By rregueir Date 2008-12-06 Time 17:18 Rev Time 0.00
Received By rregueir Date 2008-12-06 Time 17:18 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2008-10-08 Cont ID  
Sent By tgordon Date 2008-10-08 Time 15:33 Rev Time 0.45
Received By tgordon Date 2008-10-08 Time 15:33 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2008-08-12 Cont ID  
Sent By tgordon Date 2008-08-12 Time 13:44 Rev Time 1.15
Received By tgordon Date 2008-08-12 Time 13:44 Sent To  
Notes
2008-08-12 14:02:04PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM
 BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA
 ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES
 (F.S.).
  
 *** DENIED ***
 1) THE PRODUCT APPROVALS FOR A/C CONDENSER STANDS NEED
 TO BE REVIEWED AND APPROVED IN WRITING BY THE DESIGNER
 OF RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL
 APPROVAL (A SHOP REVIEW STAMP AND SIGNATURE WILL MEET
 THIS REQUIREMENT). SEE W.P.B. AMEND. 106.3.
  
 2) SEE PLUMBING REVIEW NOTE #3 REGARDING THE
 ENGINEERING BUSINESS HENZ.. PLEASE CORRECT PER FAC
 61G15-23.002 (2).
  
 3) PLEASE SHOW ON PLAN A-3.1 DETAIL 02, WHAT THE
 R-VALUE FOR THE INSULATION IS IN THE WALL. AS THIS WALL
 MAY BE CONSIDERED AN ADJACENT WALL BECAUSE THE FUTURE
 OFFICE IS NOT OCCUPIED AND THE A/C MAY NOT BE RUNNING
 AT THIS TIME. SEE 2004 FBC 13-402.1.C.1 THEN
 13-402.2.AB.1 AND .2. ( ENERGY CODE FORM 400C-04 SHOWS
 R-13 WOULD BE REQUIRED. ) PLEASE FEEL FREE TO RESPOND
 WITH ANY OTHER INFORMATION FOUND.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]

Review Stop P PLUMBING
Rev No 3 Status P Date 2008-12-16 Cont ID  
Sent By kstevens Date 2008-12-16 Time 09:52 Rev Time 0.00
Received By kstevens Date 2008-12-16 Time 09:51 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2008-10-22 Cont ID  
Sent By kstevens Date 2008-10-22 Time 16:51 Rev Time 0.00
Received By kstevens Date 2008-10-22 Time 16:51 Sent To  
Notes
2008-10-22 16:52:03PLANS OK -- ENGINEER TO UPDATE THE ADDRESS ON THE DBPR
 WEBSITE FOR FINAL APPROVAL

Review Stop P PLUMBING
Rev No 1 Status F Date 2008-08-07 Cont ID  
Sent By kstevens Date 2008-08-07 Time 12:21 Rev Time 0.00
Received By kstevens Date 2008-08-07 Time 12:21 Sent To  
Notes
2008-08-07 12:30:22DENIED
 REFERENCE: FBC-2004 PLUMBING
 FBC-2004 CHAPTER 11
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 1. SHT A-3.1 SHOW COMPLIANCE FOR THE FOLLOWING:
 ___FOR W/C'S
 A. 11-4.16.2 CLEAR FLOOR SPACE
 B. 11-4.16.3 HEIGHT
 C. 11-4.16.5 FLUSH CONTROLS
 ___FOR LAVS
 A. 11-4.16.2 CLEARANCES
 B. 11-4.16.3 CLEAR FLOOR SPACE
 (LAV SHALL BE A MINIMUM 15" OFF THE WALL TO BE CENTERED
 ON THE 30" WIDTH OF THE CLEAR FLOOR SPACE. PLEASE
 INDICATE ON PLANS).
 ___FOR TOILET ROOM
 A. 11-4.22..3 TURNING SPACE
  
 2. PER TABLE 403.1 A DRINKING FOUNTAIN IS REQUIRED FOR
 THE BUSINESS OCCUPANCE. PLEASE INDICATE THE LOCATION OF
 THE REQUIRED D.F.
  
 3. ALL MECHANICAL, ELECTRICAL & PLUMBING SHEETS. THE
 CERTIFICATE OF AUTHROIZATION IS REQUIRED IN THE TITLE
 BLOCK OF EACH SHEET.--THE ADDRESS IN THE TITLE
 BLOCK DOES NOT REFLECT THE ADDRESS OF RECORD IN THE
 STATE OF FLORIDA DBPR WEBSITE. (SEE ATTACHED SHEET).
 PLEASE UPDATE THE TITLE BLOCKS OR THE DBPR WEBSITE
 PRIOR TO RESUBMITTING TO THE CITY WPB FOR REVIEW. FAC
 61G14-23.002(2) & FS 471.025.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]
  
  

Review Stop Z ZONING
Rev No 2 Status P Date 2008-10-22 Cont ID  
Sent By mflis Date 2008-10-22 Time 08:48 Rev Time 0.00
Received By mflis Date 2008-10-22 Time 08:48 Sent To  
Notes
2008-10-22 08:49:06ZONING REVIEW: PASSED
  
 MATT FLIS - 822-1445

Review Stop Z ZONING
Rev No 1 Status P Date 2008-08-05 Cont ID  
Sent By mflis Date 2008-08-05 Time 10:04 Rev Time 0.00
Received By mflis Date 2008-08-05 Time 10:04 Sent To  
Notes
2008-08-05 10:05:34ZONING REVIEW: PASSED
  
 ** INTERIOR RENOVATION AND REPLACMENT OF EXTERIOR
 DOORS
  
 MATT FLIS - 822-1445


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved