Plan Review Details - Permit 08070817
| Plan Review Stops For Permit 08070817 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2008-10-20 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-10-20 |
Time |
14:33 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2008-10-20 |
Time |
13:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2008-09-16 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-09-16 |
Time |
11:15 |
Rev Time |
4.44 |
| Received By |
jwitmer |
Date |
2008-09-16 |
Time |
11:15 |
Sent To |
|
|
| Notes |
| 2008-09-16 14:46:11 | BUILDING PLAN REVIEW | | | PERMIT: 08070817 | | | ADD: 4200 N FLAGLER DR | | | CONT: PREMIER MODULAR BUILDING LC | | | TEL: (407)467-2189 | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | SEPTEMBER 16,2008 | | | 2ND REVIEW | | | ACTION: DENIED | | | | | | 1A) INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE | | | INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | 1B) COMPLIED. | | | | | | 1C) FL S S 713.13 NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT. NOTE: 713.13(2) IF THE | | | WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS NOT | | | ACTUALLY COMMENCED WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) | | | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE | | | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | | | 1D) COMPLIED. | | | 1E) IN THE FIRST ROUND OF REVIEWS THE MANUFACTURER HAD | | | THEIR CERTIFICATION LETTER, THIS REVIEW IT IS MISSING. | | | 106.1.2/ RULE 9B-1 | | | 2) THE SUBMITTED PLANS FOR A MODULAR BUILDING DOES NOT | | | APPEAR ON THEIR WEBSITE. MANUFACTURED (MODULAR) | | | BUILDING PROGRAM UNDER THE JURISDICTION OF THE | | | DEPARTMENET OF COMMUNITY AFFAIRS (DCA). RULE 9B-1 OF | | | THE FLORIDA ADMINISTRATIVE CODE. | | | | | | 3) MINIMUM PLAN REVIEW REQUIREMENTS OF 106.3.5.1.1 SITE | | | REQUIREMENTS, WILL REQUIRE A SITE PLAN FOR | | | 3A) PARKING | | | 3B) ACCESSIBLE PARKING SPACE 11-4.6 | | | 3C) ACCESSIBLE ROUTE 11-41.3 (1) | | | 3D) COMPLIED. | | | 3E) COMPLIED. | | | | | | 4) COMPLIED. | | | | | | 5) BUILDING PROVISO: THIS STRUCTURE IS LOCATED IN A A-5 | | | FLOOD ZONE, FBC BUILDING 3110.1.2 / CITY OF WPB CODE OF | | | ORDINANCES SECTION 94-546. STRUCTURE IS LOCATED IN AN | | | "A" FLOOD ZONE. A FLOOD ELEVATION CERTIFICATE WILL BE | | | REQUIRED. | | | | | | 5A) PLEASE INDICATE COMPLIANCE WITH CODE OF ORDINANCES | | | SEC 94-546(B)(2) NONRESIDENTIAL CONSTRUCTION. ALL NEW | | | CONSTRUCTION OR SUBSTANTIAL IMPROVEMENT OF ANY | | | COMMERCIAL, INDUSTRIAL OR OTHER NONRESIDENTIAL | | | STRUCTURE SHALL EITHER HAVE THE LOWEST FLOOR, INCLUDING | | | BASEMENT, ELEVATED TO THE LEVEL OF SIX INCHES ABOVE THE | | | BASE FLOOD ELEVATION OR, TOGETHER WITH ATTENDANT | | | UTILITY AND SANITARY FACILITIES, BE FLOODPROOFED SO | | | THAT BELOW SIX INCHES ABOVE THE FLOOD BASE LEVEL THE | | | STRUCTURE IS WATERTIGHT, WITH WALLS SUBSTANTIALLY | | | IMPERMEABLE TO THE PASSAGE OF WATER AND WITH STRUCTURAL | | | COMPONENTS HAVING THE CAPABILITY OF RESISTING | | | HYDROSTATIC AND HYDRODYNAMIC LOADS AND EFFECTS OF | | | BUOYANCY. A REGISTERED PROFESSIONAL ENGINEER OR | | | ARCHITECT SHALL CERTIFY THAT THE STANDARDS OF THIS | | | SUBSECTION ARE SATISFIED. SUCH CERTIFICATION SHALL BE | | | PROVIDED TO THE CITY ENGINEER. | | | | | | 5B) SHEET FD2 INDICATES USE OF A FILL TYPE BIRM RAISING | | | THE GRADE AROUND THE MODULAR BUILDING. THIS DOES NOT | | | MEET THE REQUIRED WATERPROOFING REQUIREMENTS OF SECTION | | | 94-546. SHEET FD2 STRUCTURAL LOAD LIMITATIONS NOTE # 7 | | | FLOOD ZONE INDICATES THIS STRUCTURE MAY NEED TO BE SET | | | HIGHER THAN PROPOSED, SINCE THE BIRM IS NOT CONSIDERED | | | A WATERPROOFING METHOD APPROVED BY THE BUILDING | | | OFFICIAL. | | | | | | 5C) SHEET FD2 THE LEFT DETAIL INDICATES THE SKIRTING | | | DETAIL IS INDIRECT CONTACT WITH SOILS. THERE IS TWO | | | CONCERNS. THE FIRST IS THE STATE APPROVED PLANS DO NOT | | | INDICATE THE USE OF NATURALLY DURABLE WOOD OR | | | PRESERVATIVE -TREATED WOOD, 2304.11.2.5. THE PLANS DO | | | INDICATE THE SOILS BEING TERMITE TREATED. | | | | | | 5D) NORMALLY THERE IS A 6" SPACE AS IN THE DETAIL AT | | | THE RIGHT WHERE THERE IS A 12 INCH GAP BETWEEN THE | | | MANUFACTURED BUILDING AND BIRM. 2304.11.2.1 JOISTS, | | | GIRDERS AND SUBFLOOR. WHERE WOOD JOISTS OR THE BOTTOM | | | OF A WOOD STRUCTURAL FLOOR WITHOUT JOISTS ARE CLOSER | | | THAN 18 INCHES (457 MM), OR WOOD GIRDERS ARE CLOSER | | | THAN 12 INCHES (305 MM) TO THE EXPOSED GROUND IN CRAWL | | | SPACES OR UNEXCAVATED AREAS LOCATED WITHIN THE | | | PERIMETER OF THE BUILDING FOUNDATION, THE FLOOR | | | ASSEMBLY (INCLUDING POSTS, GIRDERS, JOISTS AND | | | SUBFLOOR) SHALL BE OF NATURALLY DURABLE OR | | | PRESERVATIVE-TREATED WOOD. | | | | | | 5E) NOW THAT THE PLANS INDICATE THIS SOILS BIRM AROUND | | | THE PERIMETER OF THE MANUFACTURED BUILDING PLEASE | | | PROVIDE COMPLIANCE WITH 1209.1 CRAWL SPACES. | | | CRAWL SPACES SHALL BE PROVIDED WITH A MINIMUM OF ONE | | | ACCESS OPENING NOT LESS THAN 18 INCHES BY 24 INCHES | | | (457 MM BY 610 MM). | | | | | | 5F) TERMITE PROTECTION, THE STATE APPROVED PLANS | | | COVERSHEET SITE INSTALLED NOTE #2, INDICATES GUTTERS | | | AND DOWNSPOUTS IF APPLICABLE.PLEASE REVIEW 1503.6. THE | | | STATE PLANS DOES NOT HAVE ANY OVERHANGSOR EAVES. | | | | | | 6) FOUNDATION SYSTEMS, SHEET FD-1 NEITHER THE PLANS NOR | | | THE PERMIT APPLICATION PROJECT DETAILS INDICATE THE | | | LENGTH OF TIME THIS STRUCTURE IS TO BE ISSUED A C.O. | | | FORE. IF THIS IS A TEMPORARY STRUCTURE OR PERMANENT | | | STRUCTURE, SEE DEFINITIONS FOR TEMPORARY BUT SHALL NOT | | | BE PERMITTED FOR MORE THAN 180 DAYS. THE BUILDING | | | OFFICIAL IS AUTHORIZED TO GRANT EXTENSIONS FOR | | | DEMONSTRATED CAUSE. IF THIS IS TO BE A TEMPORARY | | | STRUCTURE THE INFORMATION LISTED IN 6A-B WILL BE | | | REQUIRED. | | | | | | 6A) COMPLIED AS TO TITLE BLOCK. | | | | | | 6B)COMPLIED. | | | 6C) IF THE DECISION FOR A PERMANENT STRUCTURE IS | | | PROVIDED THEN THE REQUIREMENTS FOR A PERMANENT | | | FOUNDATION SHALL BE MET: | | | 6C) (1) COMPLIED | | | 6C)(2) 1816.1 TRMITE TREATMENT SEE STATEMENTS ABOVE. | | | 6C)(3) 1209.1 CRAWL SPACE AND REQUIRED OPENING 6C)(4) | | | 1203.3.1 OPENINGS FOR UNDER-FLOOR VENTILATION 6C)(5) | | | THE FOUNDATION IS DESIGNED FOR AN B EXPOSURE WHILE THE | | | BUILDING IS DESIGNED FOR A C EXPOSURE AND LOCATED IN A | | | C ZONE.1609.4. SEE STATEMENTS ABOVE. | | | | | | 7) SINCE THE SUBMITTED FOUNDATION PLANS DOES NOT HAVE | | | APPROVAL THE FOLLOWING ITEMS MAY STILL HAVE ISSUES ONCE | | | 5A & 5B ARE RESUBMITTED THESE ITEMS WILL BE REVIEWED | | | AGAIN FOR CODE COMPLIANCE. PLEASE PROVIDE AN ACCESSIBLE | | | RAMP MEETING THE FOLLOWING REQUIREMENTS: | | | | | | 7A) 11-4.8.2 SLOPE & RISE. THE LEAST POSSIBLE SLOPE | | | SHALL BE USED FOR ANY RAMP. THE MAXIMUM SLOPE FOR A | | | RAMP IN NEW CONSTRUCTION SHALL BE 1 TO 12. THE MAXIMUM | | | RISE FOR RUN SHALL BE 30" (SEE FIGURE 16). | | | | | | 11-4.8.3. CLEAR WIDTH. THE MINIMUM CLEAR WIDTH OF A | | | RAMP SHALL BE 36". EXCEPTION: RAMPS THAT ARE PART OF A | | | REQUIRED MEANS OF EGRESS SHALL NOT BE LESS THAN 44 | | | INCHES WIDE. | | | | | | 11-4.8.4.(2) LANDINGS. ALL LANDINGS ON RAMPS SHALL NOT | | | BE LESS THAN 60" CLEAR, & THE BOTTOM OF EACH RAMP SHALL | | | HAVE NOT LESS THAN 72" OF STRAIGHT & LEVEL CLEARENCE. | | | | | | 11-4.8.4(3) IF RAMPS CHANGE DIRECTION AT LANDINGS, THE | | | MINIMUM LANDING SIZE SHALL BE 60" X 60". | | | | | | 11.4.8.5. HANDRAILS: IF A RAMP HAS A RISE GREATER THAN | | | 6" OR A HORIZONTAL PROJECTION GREATER THAN 72", THEN IT | | | SHALL HAVE HANDRAILS ON BOTH SIDES. | | | | | | 7B) PLEASE PROVIDE DESIGN CRITERIA FOR STAIRS, | | | HANDRAILS AND GUARDRAILS, 11-4.8/ 11-4.8. & 1607.7. | | | | | | 7C)COMPLIED. | | | | | | 8) 1609.1.4 PROTECTION OF OPENINGS IN WIND-BORNE DEBRIS | | | REGIONS, EXTERIOR GLAZING THAT RECEIVES POSITIVE | | | PRESSURE IN THE LOWER 60 FEET (18.3 M) IN BUILDINGS | | | SHALL BE ASSUMED TO BE OPENINGS AND THE BALANCE OF | | | GLAZED OPENINGS IN THE REST OF THE BUILDING SHALL BE | | | ASSUMED TO BE ZERO UNLESS SUCH GLAZING THAT RECEIVES | | | POSITIVE PRESSURE IS IMPACT RESISTANT OR PROTECTED WITH | | | AN IMPACT RESISTANT COVERING MEETING THE REQUIREMENTS | | | OF SSTD 12, ASTM E 1886 AND ASTM E 1996, OR MIAMI-DADE | | | TAS 201, 202 AND 203 REFERENCED THEREIN AS FOLLOWS: 1. | | | GLAZED OPENINGS LOCATED WITHIN 30 FEET (9.1 M) OF GRADE | | | SHALL MEET THE REQUIREMENTS OF THE LARGE MISSILE TEST. | | | 2. GLAZED OPENINGS LOCATED MORE THAN 30 FEET (9.1 M) | | | ABOVE GRADE SHALL MEET THE PROVISIONS OF THE SMALL | | | MISSILE TEST. | | | | | | 9) FL BLD CODE 1609.1.4: COMPONENTS & CLADDING, PROVIDE | | | 2 COPIES OF PRODUCT TESTING REPORTS, MISSING REPORTS | | | ARE AS FOLLOWS: | | | 9A) SLIDDING GLASS DOORS- SITE INSTALLED | | | | | | 10) PRODUCT APPROVALS SUBMITTED WITH PERMIT APPLICATION | | | AFTER OCTOBER 1, 2003 ARE REQUIRED TO COMPLY WITH THE | | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR INFORMATION PLEASE | | | SEE THE STATE WEBSITE AT WWW.FLORIDABUILDING.ORG. | | | PRODUCTS WITH STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS THE PRODUCT | | | IDENTITY NUMBER FROM THE STATE. IF THE PRODUCT DOES NOT | | | HAVE STATEWIDE APPROVAL, SUBMIT AN APPLICATION FOR | | | LOCAL PRODUCT APPROVAL OR SITE SPECIFIC FORM PER RULE | | | 9B-72. SEE ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 11) WPB ADMIN CODE 106.3* PRODUCT APPROVALS. THOSE | | | PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | | | | 12) COMPLIED. | | | | | | 13) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 14) INSPEAKING WITH ROBERT LORENZO FROM DCA ABOUT THE | | | STATE APPROVED PLAN FROM PRECISION HOMES, PLAN # | | | 2056-1552F MR LORENZO COULD NOT FIND THIS PLAN ON THEIR | | | LIST OF APPROVED PLANS. MR LORENZO PROVIDED US WITH THE | | | THIRD PARTY HILBORN WERNER CARTER AND ASSOCIATES | | | ADMINISTRATOR SCOTT FRANCIS. MR FRANCIS INDICATED THESE | | | ARE NOT STATE APPROVED AS OF TODAY. I ALSO SPOKE ABOUT | | | ISSUES WE SEE WITH | | | WINDOW TYPE "B" NOA LISTED AS SMALL MISSILE IMPACT, | | | WINDOW TYPE C& D REQUIRE MULLIONS WHICH ARE NOT LISTED, | | | DOOR TYPE 3 & 8 NOT HAVING WATER INFILTRATION TEST AND | | | NO ROOFING INFORMATION, PRODUCT APPROVALS. | | | MR FRANCIS INDICATED THEY WOULD CORRECT THE PLANS WHILE | | | ALSO WAITING FOR THE FINAL VERSION OF TRUSS DRAWINGS | | | AND NOT TO ISSUE THESE PLANS SINCE THERE IS NO STATE | | | APPROVAL. | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-08-20 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-08-20 |
Time |
07:34 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2008-08-20 |
Time |
07:34 |
Sent To |
|
|
| Notes |
| 2008-08-20 09:39:44 | BUILDING PLAN REVIEW | | | PERMIT: 08070817 | | | ADD: 4200 N FLAGLER DR | | | CONT: PREMIER MODULAR BUILDING LC | | | TEL: (407)467-2189 | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW | | | ACTION: DENIED | | | | | | 1A) INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE | | | INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | 1B) INFORMATIONAL: PLEASE SUBMIT 2 OF ALL SURVEYS, | | | PLANS, REPORTS, REVISIONS , PRODUCT APPROVALS AND OR | | | SUBMITTALS FOR REVIEW FOR PERMIT. IF YOUR PROJECT WILL | | | REQUIRE A RESIDENT INSPECTOR OR IF YOUR PROJECT IS A | | | THRESHOLD BUILDING REQUIRING A THRESHOLD INSPECTOR THEN | | | (3) THREE SETS OF ALL SAID DOCUMENTS WILL BE REQUIRED | | | FOR PERMIT ISSUANCE. 106.1* /2004 SUBMITTAL DOCUMENTS | | | WEST PALM BEACH ADMINISTRATIVE CODE. | | | | | | 1C) INFORMATIONAL FL S S 713.13 NOTICE OF COMMENCEMENT, | | | TO BE FILED WITH THE CLERK OF THE COURT. NOTE: | | | 713.13(2) IF THE WORK DESCRIBED IN THE NOTICE OF | | | COMMENCEMENT IS NOT ACTUALLY COMMENCED WITHIN 90 DAYS | | | AFTER THE RECORDING THEREOF, SUCH NOTICE IS NULL & | | | VOID. NOTE: 713.13(6) THE POSTING OF THE NOTICE OF | | | COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE THE FIRST | | | INSPECTION. | | | | | | 1D) INFORMATIONAL: PLANS SUBMITTED FOR PERMIT (FIRST | | | TIME REVIEW) AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO | | | THE 2004 FBC BUILDING WITH THE 2007 SUPPLEMENTS. | | | | | | 2) THE SUBMITTED PLANS FOR A MODULAR BUILDING DO NOT | | | CONTAIN THE THIRD PARTY AGENCY STAMP INDICATING THE | | | PLANS HAVE BEEN REVIEWED AND MEET THE 2004 FBC AND THE | | | MANUFACTURED (MODULAR) BUILDING PROGRAM UNDER THE | | | JURISDICTION OF THE DEPARTMENET OF COMMUNITY AFFAIRS | | | (DCA). RULE 9B-1 OF THE FLORIDA ADMINISTRATIVE CODE. | | | | | | 3) MINIMUM PLAN REVIEW REQUIREMENTS OF 106.3.5.1.1 SITE | | | REQUIREMENTS, WILL REQUIRE A SITE PLAN FOR | | | 3A) PARKING | | | 3B) ACCESSIBLE PARKING SPACE 11-4.6 | | | 3C) ACCESSIBLE ROUTE 11-41.3 (1) | | | 3D) FBC 2004 TABLE 602 & TABLE 704.8. | | | 3E) WITH NOT HAVING THE LOCATION OF STRUCTURE THIS MAY | | | BE CONSIDERED A "C" ZONE, 2004 FBC/ 2007 SUPPLEMENETS, | | | 1609.4 "C" TYPE ZONE EXPOSURES | | | | | | 4) PLEASE PROVIDE SOILS REPORT PROVIDING THE MINIMUM | | | SAFE BEARING VALUE OF THE SOILS. 1802.2.1 QUESTIONABLE | | | SOIL. WHERE THE SAFE-SUSTAINING POWER OF THE SOIL IS IN | | | DOUBT, OR WHERE A LOAD-BEARING VALUE SUPERIOR TO THAT | | | SPECIFIED IN THIS CODE IS CLAIMED, THE BUILDING | | | OFFICIAL SHALL REQUIRE THAT THE NECESSARY INVESTIGATION | | | BE MADE. SUCH INVESTIGATION SHALL COMPLY WITH THE | | | PROVISIONS OF SECTIONS 1802.4 THROUGH 1802.6 . | | | | | | 5) BUILDING PROVISO: THIS STRUCTURE IS LOCATED IN A A-5 | | | FLOOD ZONE, FBC BUILDING 3110.1.2 / CITY OF WPB CODE OF | | | ORDINANCES SECTION 94-546. STRUCTURE IS LOCATED IN AN | | | "A" FLOOD ZONE. A FLOOD ELEVATION CERTIFICATE WILL BE | | | REQUIRED. | | | | | | 6) FOUNDATION SYSTEMS, SHEET FD-1 NEITHER THE PLANS NOR | | | THE PERMIT APPLICATION PROJECT DETAILS INDICATE THE | | | LENGTH OF TIME THIS STRUCTURE IS TO BE ISSUED A C.O. | | | FORE. IF THIS IS A TEMPORARY STRUCTURE OR PERMANENT | | | STRUCTURE, SEE DEFINITIONS FOR TEMPORARY BUT SHALL NOT | | | BE PERMITTED FOR MORE THAN 180 DAYS. THE BUILDING | | | OFFICIAL IS AUTHORIZED TO GRANT EXTENSIONS FOR | | | DEMONSTRATED CAUSE. IF THIS IS TO BE A TEMPORARY | | | STRUCTURE THE INFORMATION LISTED IN 6A-B WILL BE | | | REQUIRED. | | | | | | 6A) SHEET FD-1 IS A SITE SPECIFIC FOUNDATION ENGINEERED | | | SHEET, REQUIRED TO HAVE THE SITE LOCATION INFORMATION | | | IN THE TITLEBLOCK. 106.1.1 CONSTRUCTION DOCUMENTS SHALL | | | BE OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, | | | NATURE AND EXTENT OF WORK PROPOSED UNDERTHIS PERMIT. | | | | | | 6B) SHEET FD-1 PLEASE INDICATE WHICH TYPE OF PIER | | | SYSTEM WILL BE USED AND IF IT IS THE ALTERNATE SYSTEM. | | | PLEASE SPECIFY IF THE PIERS ARE TO BE FILLED CELL WITH | | | CONCRETE OR TYPE M OR S MORTAR OR HOLLOW | | | CONCRETE MASONARY UNIT. PLEASE SEE 1805.5.7 (3) (3.2) | | | EXCEPTION: 4 TIMES THE LEAST DIMENSION AND DESIGNS | | | EMPLOYING LATERAL BEARINGWILL BE REQUIRED. | | | | | | 6C) IF THE DECISION FOR A PERMANENT STRUCTURE IS | | | PROVIDED THEN THE REQUIREMENTS FOR A PERMANENT | | | FOUNDATION SHALL BE MET: | | | 6C) (1) 1805.2 DEPTH OF FOUNDATION | | | 6C)(2) 1816.1 TRMITE TREATMENT | | | 6C)(3) 1209.1 CRAWL SPACE AND REQUIRED OPENING 6C)(4) | | | 1203.3.1 OPENINGS FOR UNDER-FLOOR VENTILATION 6C)(5) | | | THE FOUNDATION IS DESIGNED FOR AN B EXPOSURE WHILE THE | | | BUILDING IS DESIGNED FOR A C EXPOSURE AND LOCATED IN A | | | C ZONE.1609.4. | | | | | | 7) SINCE THE SUBMITTED PLANS DON NOT HAVE STATE | | | APPROVAL THROUGH THE DCA FOR MODULAR BUILDINGS A | | | THROUGH REVIEW OF THE PLANS WILL BE REQUIRED. PLEASE | | | PROVIDE AN ACCESSIBLE RAMP MEETING THE FOLLOWING | | | REQUIREMENTS: | | | | | | 7A) 11-4.8.2 SLOPE & RISE. THE LEAST POSSIBLE SLOPE | | | SHALL BE USED FOR ANY RAMP. THE MAXIMUM SLOPE FOR A | | | RAMP IN NEW CONSTRUCTION SHALL BE 1 TO 12. THE MAXIMUM | | | RISE FOR RUN SHALL BE 30" (SEE FIGURE 16). | | | | | | 11-4.8.3. CLEAR WIDTH. THE MINIMUM CLEAR WIDTH OF A | | | RAMP SHALL BE 36". EXCEPTION: RAMPS THAT ARE PART OF A | | | REQUIRED MEANS OF EGRESS SHALL NOT BE LESS THAN 44 | | | INCHES WIDE. | | | | | | 11-4.8.4.(2) LANDINGS. ALL LANDINGS ON RAMPS SHALL NOT | | | BE LESS THAN 60" CLEAR, & THE BOTTOM OF EACH RAMP SHALL | | | HAVE NOT LESS THAN 72" OF STRAIGHT & LEVEL CLEARENCE. | | | | | | 11-4.8.4(3) IF RAMPS CHANGE DIRECTION AT LANDINGS, THE | | | MINIMUM LANDING SIZE SHALL BE 60" X 60". | | | | | | 11.4.8.5. HANDRAILS: IF A RAMP HAS A RISE GREATER THAN | | | 6" OR A HORIZONTAL PROJECTION GREATER THAN 72", THEN | | | IT | | | SHALL HAVE HANDRAILS ON BOTH SIDES. | | | | | | 7B) PLEASE PROVIDE DESIGN CRITERIA FOR STAIRS, | | | HANDRAILS AND GUARDRAILS, 11-4.8/ 11-4.8. & 1607.7. | | | | | | 7C) WALL SECTIONS THROUGH PROVIDING A CONTINIOUS LOAD | | | PATH 1609.6.2.1 MAIN WIND-FORCE RESISTING SYSTEM. | | | | | | 8) 1609.1.4 PROTECTION OF OPENINGS IN WIND-BORNE DEBRIS | | | REGIONS, EXTERIOR GLAZING THAT RECEIVES POSITIVE | | | PRESSURE IN THE LOWER 60 FEET (18.3 M) IN BUILDINGS | | | SHALL BE ASSUMED TO BE OPENINGS AND THE BALANCE OF | | | GLAZED OPENINGS IN THE REST OF THE BUILDING SHALL BE | | | ASSUMED TO BE ZERO UNLESS SUCH GLAZING THAT RECEIVES | | | POSITIVE PRESSURE IS IMPACT RESISTANT OR PROTECTED WITH | | | AN IMPACT RESISTANT COVERING MEETING THE REQUIREMENTS | | | OF SSTD 12, ASTM E 1886 AND ASTM E 1996, OR MIAMI-DADE | | | TAS 201, 202 AND 203 REFERENCED THEREIN AS FOLLOWS: 1. | | | GLAZED OPENINGS LOCATED WITHIN 30 FEET (9.1 M) OF GRADE | | | SHALL MEET THE REQUIREMENTS OF THE LARGE MISSILE TEST. | | | 2. GLAZED OPENINGS LOCATED MORE THAN 30 FEET (9.1 M) | | | ABOVE GRADE SHALL MEET THE PROVISIONS OF THE SMALL | | | MISSILE TEST. | | | | | | 9) FL BLD CODE 1609.1.4: COMPONENTS & CLADDING, PROVIDE | | | 2 COPIES OF PRODUCT TESTING REPORTS, MISSING REPORTS | | | ARE AS FOLLOWS: | | | 9A) FIXED WINDOWS NOA 08-0429.10 MISSILE IMPACT RATING: | | | NONE | | | 9B) MULLIONS | | | 9C) SWING EXTERIOR DOORS | | | 9D) SLIDDING GLASS DOORS | | | 9E) LOUVER | | | 9F) HARDIPLANK SIDING | | | 9G) STORM SHUTTERS - NON-IMPACT WINDOWS PROVIDE STORM | | | PANEL INFORMATION WITH INSTALLATION SCHEDULE AND KEY | | | PLAN WITH | | | SPECIFIC ANCHORS AND MOUNTING TO BE USED FOR ALL | | | NON-IMPACT GLAZING. FBC 1606.1.4. | | | 9H) ROOFING ASSEMBLIES | | | | | | | | | 10) PRODUCT APPROVALS SUBMITTED WITH PERMIT APPLICATION | | | AFTER OCTOBER 1, 2003 ARE REQUIRED TO COMPLY WITH THE | | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR INFORMATION PLEASE | | | SEE THE STATE WEBSITE AT WWW.FLORIDABUILDING.ORG. | | | PRODUCTS WITH STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS THE PRODUCT | | | IDENTITY NUMBER FROM THE STATE. IF THE PRODUCT DOES NOT | | | HAVE STATEWIDE APPROVAL, SUBMIT AN APPLICATION FOR | | | LOCAL PRODUCT APPROVAL OR SITE SPECIFIC FORM PER RULE | | | 9B-72. SEE ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 11) WPB ADMIN CODE 106.3* PRODUCT APPROVALS. THOSE | | | PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | | | | 12) ENERGY CALCULATIONS ARE MISSING THE INPUT DATA | | | REPORT, CODE COMPLIANCE CAN NOT BE CHECKED WITHOUT THE | | | INPUT DATA REPORT.13-415.2. | | | | | | A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A | | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | | THIS REVIEW. | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2008-10-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-10-21 |
Time |
10:05 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-10-21 |
Time |
10:05 |
Sent To |
|
|
| Notes |
| 2008-10-21 10:07:01 | SEPARATE PERMIT FOR THE ELECTRICAL SERVCIE FEEDING THE | | | BUILDINGS. | | | | | | *** NO CHANGES ARE PERMITTED TO THE BASE BUILDING | | | INCLUDING LOW VOLTAGE WILL VOID THE STATE APPROVAL. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2008-09-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-09-30 |
Time |
11:57 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-09-30 |
Time |
11:57 |
Sent To |
|
|
| Notes |
| 2008-09-30 11:57:34 | | | | ** DENIED REVIEW ** | | | | | | 1) NOTE: PLEASE SEE THE VERSION OF THE SUBMITTED ENERGY | | | CALCULATIONS IS NOT CORRECT. PLEASE SEE 13-400.3.A AS | | | THE VERSION ADOPTED BY THE FLORIDA BUILDING CODE IS | | | 2.5. THE SUBMITTED IS VERSION 3.0. PLEASE KNOW IT IS | | | THE UNDERSTANDING OF THIS OFFICE THAT A FREE PATCH IS | | | AVAILABLE ON ENERGY GAUGE WEBSITE TO CHANGE TO VERSION | | | 2.5. | | | ** PLEASE ALSO SEE THE COUNT OF FIXTURES IN THE INPUT | | | DATA REPORT OF THE SUBMITTED ENERGY CALCULATIONS IS NOT | | | POSSIBLE AS EACH TYPE IS SHOWN AS ONE FIXTURE. PLEASE | | | SEE THE PLANS HAVE NUMEROUS FIXTURES NOT ONLY ONE IS | | | EACH LOCATION/ZONE/SPACE. | | | PLEASE BE SURE TO SEE 13-415.2.,13-415.2.ABC.1.1,.1.2 | | | AND .1.3. | | | PLEASE ALSO SEE THE EXTERIOR LIGHTING AS THE SUBMITTED | | | INPUT DATA REPORT ONLY INDICATES A TOTAL OF FIVE | | | FIXTURES WHICH IS NOT POSSIBLE BASED ON THE PLANS | | | SUBMITTED. THE PLANS SHOW A SUBSTANTIALLY HIGHER NUMBER | | | OF FIXTURES. THE WATTAGE OF EACH OF THESE FIXTURES IS | | | ALSO NOT THE SAME AS SHOWN ON THE IDR. THE IDR SHOWS A | | | TOTAL OF 60WATTS, YET THE PLANS INDICATE 100WATT | | | FIXTURES. | | | | | | ** PLEASE BE SURE TO COORDINATE ALL FIXTURE SON PLANS | | | WITH THE INPUT DATA REPORT FOR TYPES, WATTAGES, NUMBER | | | OF FIXTURES ETC. | | | ** PLEASE SEE THE JURISDICTION IS NOT CORRECT. THE | | | APPLICATION IS LOCATED IN THE CITY OF WEST PALM BEACH | | | | | | 2) NOTE: IF PLANS HAVE A * STATE APPROVAL* PLEASE BE | | | SURE ALL PLANS CONTAIN THE STATE STAMPS. THE ELECTRICAL | | | PLANS AS SUBMITTED DO NOT CONTAIN ANY STAMPS FROM ANY | | | OF THE LISTED REVIEWERS. | | | | | | 3) NOTE: PLEASE SEE THE PACKAGE DOES INCLUDE ANY | | | ELECTRICAL RISER FOR SERVICE TO CONNECTION OF | | | ELECTRICAL SERVICE OR EQUIPMENT. | | | 230.70.230.71.230.72.230.76,230.79, 250.50, 215.5, 545 | | | ETC | | | FBC 106.1.1,106.3.5.1.2 FOR ADDITIONAL INFORMATION AND | | | CLARITY. | | | | | | 4) NOTE: PLEASE SEE PANEL SCHEDULES ARE NOT COMPLETE OR | | | SPECIFIC AS REQUIRED PER 408.4 OF THE 2005 NFPA-70. | | | PLEASE SEE COMMENTARY UNDER THE NEC SECTION GIVEN AS | | | LISTING *LIGHTING* OR *RECEPTACLES* IN LIEU OF SPECIFIC | | | ROOMS OR LOCATIONS IS NOT ACCEPTABLE. | | | | | | 5) NOTE: PLEASE SEE FBC 13-413.2.ABC.2.1 AND2.2 FOR | | | MISSING NOTES REQUIRED ON PLANS. | | | | | | 6) NOTE: PLEASE SEE FBC 13-413.1.ABC.1.1 AND .1.2 FOR | | | MISSING VOLTAGE DROP CALCULATIONS FOR WORST CASE | | | SCENARIO. | | | | | | 7) NOTE: PLANS INDICATE SOME SORT OF NOTES FOR HORNS | | | AND STROBES HOWEVER THERE IS NOT INDICATION OR SHOWN | | | DESIGN MEETING MINIMUM LEVELS AND LOCATIONS FOR FBC | | | 11-4.28.1,.2 AND .3 FOR ADA COMPLIANCE. | | | PLEASE COMPLETE PLANS AND MINIMUM DEVICE LOCATIONS, | | | HEIGHTS, AND LEVELS FOR MINIMUM CODE COMPLIANCE. | | | | | | 8) NOTE: AS SOME INFORMATION HAS NOT BEEN SUBMITTED OR | | | SHOWN AT THIS TIME THERE MAY VERY WELL BE NEW COMMENTS | | | ON THE FOLLOWING REVIEW WHICH CAN NOT BE MADE AT THIS | | | TIME. BASED ON PLANS SUBMITTED A REVIEW WAS DONE AS | | | PLANS DID NOT CONTAIN STAMPS. IN EITHER CASE PLANS ARE | | | STILL REQUIRED TO MEET MINIMUM CODE DESIGN AND | | | COMPLIANCE PER FBC AND OTHER ADOPTED CODES PER FS | | | 553.73. | | | | | | | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2008-08-13 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-08-13 |
Time |
16:19 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-08-13 |
Time |
16:19 |
Sent To |
|
|
| Notes |
| 2008-08-13 16:19:35 | | | | | | | ** NO STATE APPROVAL OR STAMPS ON PLANS. | | | | | | | | | **DENIED** | | | | | | 1) NOTE: PLEASE SEE COMPLIANCE WITH THE ENERGY CODE IS | | | NOT MET. PLEASE SEE THE CERTIFICATION SHEETS IN BOTH | | | SETS ARE NOT ORIGINAL. IN FACT THEY DO NOT CONTAIN A | | | SIGNATURE, DATE, OR SEAL FROM THE LISTING DESIGN | | | PROFESSIONAL AS REQUIRED. | | | PLEASE SEE FS 471.025, FAC 61G15-23.002, FBC 13-103.1. | | | | | | 2) NOTE: PLANS SUBMITTED ARE NOT COMPLETE, NO RISER | | | DIAGRAM, NO GROUNDING, NO SERVICE ENTRANCE CONDUCTORS, | | | NO FEEDERS, NO AIC RATINGS, NO LOAD CALCULATIONS ETC | | | 230.70,230.71,230.72,215.5,215.3,240.4,310.16,408.4,220 | | | ETC. | | | | | | 3) NOTE: PLEASE SEE THE ENERGY CALCULATIONS SUBMITTED | | | ARE INCOMPLETE. PLEASE SEE PAGE TWO WHICH SPECIFICALLY | | | STATES THE INPUT DATA REPORT SHALL ACCOMPANY THE | | | CALCULATIONS. | | | AS THESE ARE NOT COMPLETE AT THIS TIME, NO VERIFICATION | | | OF CODE COMPLIANCE CAN BE DONE. | | | PLEASE SEE ADDRESS IS NOT COMPLETE. | | | PLEASE SEE JURISDICTION IS NOT CORRECT. | | | PLEASE SEE INFORMATION FOR MOST OTHER ITEMS ON COVER | | | SHEET ARE ALSO NOT COMPLETE. | | | | | | ** PLEASE BE SURE TO SEE 13-415.2, | | | 13-415.2.ABC.1.1,.1.2 AND .1.3. | | | | | | 4) NOTE: PLEASE SEE FBC 11-4.28.1,.2 AND .3. NO | | | COMPLIANCE FOR ADA DEVICES IS SHOWN ON PLANS. | | | BASE PLANS ARE REQUIRED TO SHOW AT LEAST THE MINIMUM | | | FOR CODE COMPLIANCE. | | | | | | 5) NOTE: PLEASE SEE 13-415.1.ABC.1.4 FOR REQUIRED | | | CONTROLS FOR EXTERIOR LIGHTS. STATING *TIMER* ON PLANS | | | DOES NOT SHOW MINIMUM. | | | | | | 6) NOTE: PLEASE BE SURE TO COMPLETE ALL CIRCUITING, ALL | | | DESIGNATIONS ON PLANS AND COORDINATE WITH PANEL | | | SCHEDULES, FIXTURE LEGEND. | | | FBC 106.1.1 FOR ADDITIONAL INFORMATION AND CLARITY . | | | NEC 2005, FBC 2004W/2007 REVS. | | | | | | *** AS THERE IS MUCH INFORMATION NOT YET SUBMITTED | | | THERE MAY VERY WELL BE NEW COMMENTS ON THE FOLLOWING | | | REVIEW WHICH CAN NOT BE MADE AT THIS TIME. | | | | | | | | | **IMPORTANT** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | | TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
4 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
P |
Date |
2008-10-20 |
|
|
Cont ID |
|
| Sent By |
|
Date |
2008-10-20 |
Time |
9:15 |
Rev Time |
1.00 |
| Received By |
|
Date |
2008-10-20 |
Time |
8:15 |
Sent To |
|
|
| Notes |
| 2008-10-20 08:55:52 | PASSED. |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
F |
Date |
2008-09-19 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2008-09-19 |
Time |
11:08 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2008-09-19 |
Time |
10:49 |
Sent To |
|
|
| Notes |
| 2008-09-19 11:07:43 | FAILED FOR FOLLOWING REASONS: | | | | | | 1. PLEASE SHOW ON DRAWINGS THE SILT FENCE AROUND THE | | | WHOLE SITE, & TURBIDITY AROUND CATCH BASINS, WATER | | | FALLS, LAKE, CANAL IF YOU HAVE THEM DURING CONSTRUCTION | | | AND ALL DEMOLITION PHASE. HEIGHT OF FENCE SHOULD BE | | | HIGH ENOUGH PER FDEP TO STOP DUST PARTICLES. | | | | | | 2. PLEASE PROVIDE A COPY OF BOND FOR ORDINANCE NO. | | | 4060-07: | | | | | | ALL DEMOLITION AND NEW CONSTRUCTION PERMITS, WITH | | | EXCEPTION OF SINGLE FAMILY, DUPLEX AND ACCESSORY | | | APARTMENT, SHALL POST BONDS OR DEPOSITS FOR THE | | | FOLLOWING: | | | | | | 1. EROSION CONTROL, AND | | | 2. LAND STABILIZATION | | | | | | THE AMOUNT OF THE EROSION CONTROL AND LAND | | | STABILIZATION BONDS SHALL BE DETERMINED BY THE ENGINEER | | | OF RECORD USING THE CURRENT CITY COST SCHEDULE AND | | | VERIFIED BY THE CITY'S ENGINEERING SERVICES DEPT. | | | PLEASE CONTACT BRIAN MOREE, ENG SERVICES CONSTRUCTION | | | SUPERVISOR, AT 561- 494 -1040 FOR MORE INFORMATION. | | | | | | UPON VERTICAL CONSTRUCTION COMMENCEMENT, PAYMENT IN | | | FULL OF ALL APPLICABLE FEES, AND COMPLIANCE WITH ALL | | | TERMS AND CONDITIONS OF ANY POSTED BOND, THE PERMITTEE | | | MAY REQUEST RELEASE OF THE BONDS OR DEPOSITS. | | | | | | A COPY OF ORDINANCE NO. 4060-07 MAY BE OBTAINED FROM | | | THE CITY CLERK'S OFFICE LOCATED ON THE FIRST FLOOR. | | | | | | 3. PLEASE SHOW ON DRAWINGS DUMPSTER & ITS ENCLOSURE | | | DETAILS PER CITY OF WPB, & LOCATION ON DWG, LOCATION | | | MUST BE ACCESSIBLE FOR PICKUP TRUCK. | | | | | | 4. PLEASE SHOW ON CALCULATION THAT YOU HAVE CONSIDERED | | | FLOOD ZONE AREA, & 5,10, 25,50,100 YEAR FLOOD CRITERIA | | | AND CROWN OF THE ROAD WHEN YOU DETERMINE THE FIRST | | | FLOOR ELEVATION. FIRST FLOOR ELEVATION SHOULD BE | | | ATLEAST 1 FOOT HIGHER THAN HIGHEST CROWN OF THE ROAD. | | | | | | 5. PLEASE SHOW ON DRAINAGE DRAWING THE SITE AREA, | | | GREEN, LAKE,PARKING AREA, IMPERVIOUS,PERVIOUS AREA YOU | | | ARE DEVELOPING FOR THIS PROJECT . PLEASE MAKE SURE | | | THESE AREAS SHOWN ON DRAINAGE DRAWINGS MUST MATCH WITH | | | AND USED IN STORM WATER QUALITY CALCULATIONS. PLEASE | | | PROVIDE A COPY OF SFWMD PERMIT,, GEO-TECH REPORT & | | | STORM WATER QUALITY CALCULATIONS TO 1000 45TH STREET | | | FOR THEIR APPROVAL BEFORE WE ISSUE A PERMIT. | | | | | | | | | 6. PLEASE SHOW ALL STORM WATER PIPES AROUND YOUR SITE | | | SO, WE CAN SEE THE LAYOUT OF STORM WATER PIPES FROM ALL | | | OTHER STORM WATER PIPES. PLEASE SHOW DETAIL OF THE | | | CONTROL STRUCTURES WITH ELEVATIONS, NOTCHES, BLEEDING | | | ELEVATION, ETC ON DRAWINGS, CALCULATION FOR | | | EXFILTRATION TRENCHES, PLEASE SHOW DRY DETENTION/WET | | | DETENTION AREAS IN STORM WATER CALS IF YOU HAVE ALL | | | THESE. PLEASE RESUBMIT GEO-TECH REPORT AND ALL | | | ENVRONMENTAL REPORT. | | | | | | 7. ALSO PLEASE SHOW ALL CATCH BASINS NEAREST, AROUND | | | YOUR SITE FOR STORM WATER DRAIN SO YOUR SITE DO NOT GET | | | FLOODED AND HAVE ENOUGH DRAINS. | | | | | | | | | PLEASE RESPOND EACH ITEM IN DETAIL WITH REFERENCE | | | DRAWINGS TO EXPEDITE YOUR PERMITTING PROCESS | | | | | | RASIK CHOKSHI 805-6723 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2008-08-22 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2008-08-22 |
Time |
14:48 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2008-08-22 |
Time |
14:42 |
Sent To |
|
|
| Notes |
| 2008-08-22 14:48:35 | FAILED FOR FOLLOWING REASONS: | | | | | | 1. PLEASE PROVIDE A COPY OF NOTICE OF INTENT (NOI). | | | PLEASE APPLY AT FDEP, NPDES STORMWATER SECTION FOR | | | NOI. | | | YOU CAN GET NOI INFO FROM | | | WWW.DEP.STATE.FL.US/WATER/STORMWATER/NPDES/ | | | NOTICE OF INTENT DEP FORM 62-621.300(4)(B), | | | EFFECTIVE MAY 1, 2003 | | | | | | 2. PLEASE SHOW ON DRAWINGS THE SILT FENCE DETAILS & | | | TURBIDITY DETAILS OFPOLLUTION PREVENTION . PLEASE | | | SHOW ON DRAWINGS THE SILT FENCE AROUND THE WHOLE SITE, | | | & TURBIDITY AROUND CATCH BASINS DURING CONSTRUCTION AND | | | ALL DEMOLITION PHASE.HEIGHT OF FENCE SHOULD BE HIGH | | | ENOUGH PER FDEP TO STOP DUST PARTICLES. | | | | | | 3. PLEASE PROVIDE A COPY OF BOND FOR ORDINANCE NO. | | | 4060-07: | | | | | | ALL DEMOLITION AND NEW CONSTRUCTION PERMITS, WITH | | | EXCEPTION OF SINGLE FAMILY, DUPLEX AND ACCESSORY | | | APARTMENT, SHALL POST BONDS OR DEPOSITS FOR THE | | | FOLLOWING: | | | | | | 1. EROSION CONTROL, AND | | | 2. LAND STABILIZATION | | | | | | THE AMOUNT OF THE EROSION CONTROL AND LAND | | | STABILIZATION BONDS SHALL BE DETERMINED BY THE ENGINEER | | | OF RECORD USING THE CURRENT CITY COST SCHEDULE AND | | | VERIFIED BY THE CITY'S ENGINEERING SERVICES DEPT. | | | PLEASE CONTACT BRIAN MOREE, ENG SERVICES CONSTRUCTION | | | SUPERVISOR, AT 561- 494 -1040 FOR MORE INFORMATION. | | | | | | UPON VERTICAL CONSTRUCTION COMMENCEMENT, PAYMENT IN | | | FULL OF ALL APPLICABLE FEES, AND COMPLIANCE WITH ALL | | | TERMS AND CONDITIONS OF ANY POSTED BOND, THE PERMITTEE | | | MAY REQUEST RELEASE OF THE BONDS OR DEPOSITS. | | | | | | A COPY OF ORDINANCE NO. 4060-07 MAY BE OBTAINED FROM | | | THE CITY CLERK'S OFFICE LOCATED ON THE FIRST FLOOR. | | | | | | 4. PLEASE SHOW ON DRAWING ALL CITY STANDARDS NOTES FOR | | | SIDEWALK, DRIVEWAY, APPROACH, PARKINGS, HANDICAP | | | PARKINGS, DUMPSTER ENCLOSURE, YOU CAN GET A C D FOR ALL | | | CITY STANDARDS NOTES FROM 1000, 45 STREET, ENGINEERING | | | SERVICES, PHONE# 494-1040 | | | | | | 5. PLEASE SHOW ON DRAWINGSDUMPSTER & ITS ENCLOSURE | | | DETAILS PER CITY OF WPB, &LOCATION ON DWG, LOCATION | | | MUST BE ACCESSIBLE FOR PICKUP TRUCK. | | | | | | 6. PLEASE SHOW ON CALCULATION THAT YOU HAVE CONSIDERED | | | FLOOD ZONE AREA, & 5,10, 25, 100 YEAR FLOOD CRITERIA | | | AND CROWN OF THE ROAD WHEN YOU DETERMINE THE FIRST | | | FLOOR ELEVATION. FIRST FLOOR ELEVATION SHOULD BE | | | ATLEAST 1 FOOT HIGHER THAN HIGHEST CROWN OF THE ROAD. | | | | | | 7. PLEASE SHOW ON DRAINAGE DRAWINGTHE SITE AREA, | | | GREEN, LAKE,PARKING AREA, IMPERVIOUS,PERVIOUS AREAYOU | | | ARE DEVELOPING FOR THIS PROJECT . PLEASEMAKE SURE | | | THESE AREAS SHOWN ON DRAINAGE DRAWINGS MUST MATCH WITH | | | AND USED IN STORM WATER QUALITY CALCULATIONS. PLEASE | | | PROVIDE A COPY OF THESE CALCULATIONS. | | | | | | 8. PLEASE SHOW ALL STORM WATER PIPES AROUND YOUR SITE | | | SO, WE CANSEE THE LAYOUT OF STORM WATER PIPES FROM | | | ALL OTHER STORM WATER PIPES. PLEASE SHOW DETAIL OF THE | | | CONTROL STRUCTURESWITH ELEVATIONS, NOTCHES, BLEEDING | | | ELEVATION, ETC ON DRAWINGS, CALCULATION FOR | | | EXFILTRATION TRENCHES, PLEASE SHOW DRY DETENTION/WET | | | DETENTION AREAS IN STORM WATER CALS IF YOU HAVE ALL | | | THESE. PLEASE RESUBMIT GEO-TECH REPORT AND ALL | | | ENVRONMENTAL REPORT. | | | | | | 9. ALSO PLEASE SHOW ALL CATCH BASINS NEAREST,AROUND | | | YOUR SITE FOR STORM WATER DRAIN SO YOUR SITE DO NOT GET | | | FLOODED AND HAVE ENOUGH DRAINS. | | | | | | 10. PLEASE PROVIDE A COPY OF SFWMD PERMIT,, GEO-TECH | | | REPORT&STORM WATER QUALITY CALCULATIONS TO 1000 | | | 45TH STREET FOR THEIR APPROVAL BEFORE WE ISSUE A | | | PERMIT. | | | | | | 11. WATER & SEWER PLANS MUST BE APPROVED FROM MANNY G. | | | OF 1000 45TH STREET BEFORE WE ISSUE A PERMIT. | | | | | | PLEASE RESPOND EACH ITEM IN DETAIL WITH REFERENCE | | | DRAWINGSTO EXPEDITE YOUR PERMITTING PROCESS | | | | | | RASIK CHOKSHI805-6723 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2008-10-21 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-10-21 |
Time |
11:15 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-10-21 |
Time |
11:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2008-09-30 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-09-30 |
Time |
15:37 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-09-30 |
Time |
15:37 |
Sent To |
|
|
| Notes |
| 2008-09-30 15:37:25 | ***DENIED*** | | | | | | 1) PLEASE SEE NEW COMMENT. (1A) | | | | | | 2) WHERE RAMPS ARE PROVIDED, WORK TO COMPLY WITH | | | APPLICABLE BUILDING CODES AND NFPA 101, SEC. 7.2.5. | | | | | | 3) PROVIDE PRESCRIPTIVE STRENGTH REQUIREMENTS FOR | | | HANDRAILS AND GUARDRAILS. | | | | | | 4) ADDRESS REQUIRED ON ALL BUILDINGS THAT SHALL BE | | | MINIMUM 6" IN HEIGHT, 1" WIDTH AND CONTRASTING WITH | | | BACKGROUND. | | | | | | 5) PLEASE PROVIDED DISTANCE FROM BUILDING TO CLOSEST | | | FIRE HYDRANT. | | | | | | NEW COMMENTS: | | | | | | 1A) SHEET E1 INDICATES MANUEL PULL STATIONS AND HORNS | | | BUT NO VISUAL APPLIANCES. PLEASE ADD TO DRAWINGS AND | | | ELECTRICAL SYMBOLS. | | | | | | 6) EXIT SIGNS APPEAR TO BE COMBINATION TYPE WITH | | | EMERGENCY LIGHTING BUT NOT SHOWN UNDER ELECTRICAL | | | SYMBOLS FOR VERIFICATION. | | | | | | 7) IF A FIRE ALARM SYSTEM IS PART OF THIS PROJECT, | | | PLEASE SHOW ALL EQUIPMENT INCLUDING THE FIRE ALARM | | | CONTROL PANEL. | | | | | | 8) VERIFY THE LOCATIONS OF EMERGENCY LIGHTING | | | FACILITIES ON SHEET E2. | | | | | | 9) OCCUPANT LOAD SIGN WILL BE REQUIRED AT TIME OF FINAL | | | INSPECTION. CONTACT BUREAU OF FIRE PREVENTION AT (561) | | | 804-4724 FOR ASSISTANCE. | | | | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | | FIRE PLAN REVIEW | | | FIRE PREVENTION (561) 804-4756 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2008-08-26 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-08-26 |
Time |
13:54 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-08-26 |
Time |
13:54 |
Sent To |
|
|
| Notes |
| 2008-08-26 13:59:57 | ***DENIED*** | | | | | | 1) PLANS INDICATE A FIRE ALARM SYSTEM ON SHEET CV AND | | | SHEET EV1 BUT NO EQUIPMENT IS ILLUSTRATED ON DRAWINGS | | | OR UNDER ELECTRICAL SYMBOLS. ADDITIONALLY, SEPARATE | | | SHOP DRAWINGS AND PERMIT REQUIRED PRIOR TO EQUIPMENT | | | INSTALLATION. | | | | | | 2) WHERE RAMPS ARE PROVIDED, WORK TO COMPLY WITH | | | APPLICABLE BUILDING CODES AND NFPA 101, SEC. 7.2.5. | | | | | | 3) PROVIDE PRESCRIPTIVE STRENGTH REQUIREMENTS FOR | | | HANDRAILS AND GUARDRAILS. | | | | | | 4) ADDRESS REQUIRED ON ALL BUILDINGS THAT SHALL BE | | | MINIMUM 6" IN HEIGHT, 1" WIDTH AND CONTRASTING WITH | | | BACKGROUND. | | | | | | 5) PLEASE PROVIDED DISTANCE FROM BUILDING TO CLOSEST | | | FIRE HYDRANT. | | | | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | | FIRE PLAN REVIEW | | | FIRE PREVENTION (561) 804-4756 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2008-10-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-10-24 |
Time |
08:53 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-10-24 |
Time |
08:53 |
Sent To |
M |
|
| Notes |
| 2008-10-24 08:54:31 | TO "M" BOX/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2008-10-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-10-22 |
Time |
14:24 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-10-22 |
Time |
14:24 |
Sent To |
M |
|
| Notes |
| 2008-10-22 14:24:25 | TO "M" BOX/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-10-06 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-10-06 |
Time |
16:28 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-10-06 |
Time |
16:27 |
Sent To |
|
|
| Notes |
| 2008-10-06 16:32:58 | TO "COMM" BD#37 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-09-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-09-09 |
Time |
09:06 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-09-09 |
Time |
09:06 |
Sent To |
|
|
| Notes |
| 2008-09-09 09:06:34 | TO "COMM" BD#60 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-08-26 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-08-26 |
Time |
14:06 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-07-30 |
Time |
16:19 |
Sent To |
|
|
| Notes |
| 2008-07-30 16:22:22 | TO "COMM" BD#54 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2008-11-08 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-11-08 |
Time |
15:36 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-11-08 |
Time |
15:36 |
Sent To |
PC |
|
| Notes |
| 2008-11-08 15:37:20 | MECH DETAIL FOR CU ATTACHMENT |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2008-10-22 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-10-22 |
Time |
15:18 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-10-22 |
Time |
15:11 |
Sent To |
PC |
|
| Notes |
| 2008-11-08 15:39:10 | CONDITIONS OF PROVISO SATISFIED FOR PLAN REVIEW. | | 2008-10-22 15:18:39 | ***************PROVISO******************* | | | DETAIL FOR INSTALLATION OF OUTDOOR CONDENSING UNITS HAS | | | BEEN SUBMITTED. THE DETAIL IS NTO SIGNED AND SEALED BY | | | THE ENGINEER OF RECORD. PROVIDE SIGNED AND SEALED | | | DETAIL FOR PLAN REVIEW PRIOR TO MECHANICAL INSPECTION. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2008-09-29 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-09-29 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-09-29 |
Time |
08:51 |
Sent To |
|
|
| Notes |
| 2008-09-29 10:09:11 | ***NOTE*** | | | | | | SUBMIT A SEPARATE PLAN AND PERMIT APPLICATION FOR THE | | | SITE INSTALLED MECHANICAL COMPONENTS. PLANS INDICATE | | | THIS WORK IS TO BE PERFORMED BY "OTHERS." | | | | | | PREVIOUS REVIEW COMMENTS HAVE NOT BEEN ADDRESSED. | | | HOWEVER, AS OF 9/26/08, THIS PLAN IS APPROVED AND | | | LISTED ON THE DCA WEBSITE UNDER PLAN #: 2056-1552F. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2008-08-21 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-08-21 |
Time |
11:04 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-08-20 |
Time |
15:29 |
Sent To |
|
|
| Notes |
| 2008-08-21 11:04:35 | REVIEW #: 1ST | | | ACTION: DENIED | | | | | | FBC 2004 CODE FAMILY W/ 2007 SUPPLEMENTS | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | 1. THESE PLANS ARE FOR A MODULAR BUILDING. HOWEVER, | | | THERE IS NO INDICATION ON PLANS THAT THEY HAVE BEEN | | | SUBMITTED UNDER THE DCA MODULAR BUILDING PROGRAM | | | ESTABLISHED UNDER F.S. 553. THEREFORE, THESE PLANS MUST | | | BE REVIEWED FOR THE REQUIREMENTS OF NEW SITE-BUILT | | | CONSTRUCTION IN ACCORDANCE WITH THE FLORIDA BUILDING | | | CODE. | | | | | | 2. SHOW THE SIZES OF ALL SUPPLY AND RETURN AIR DUCTS AS | | | WELL AS THE CFM BEING SUPPLIED OR RETURNED AT EACH | | | REGISTER, GRILL OR DIFFUSER. AN AIR DISTRIBUTION SYSTEM | | | SHALL BE DESIGNED AND INSTALLED TO SUPPLY THE REQUIRED | | | DISTRIBUTION OF AIR IN ACCORDANCE WITH FBCM 603.1. SHOW | | | BALANCED RETURN AIR IN ACCORDANCE WITH FBCM 601.4. | | | | | | 3. SHOW MEANS AND LOCATION OF CONDENSATE DISPOSAL. | | | CONDENSATE FROM ALL COOLING COILS AND EVAPORATORS SHALL | | | BE CONVEYED FROM THE DRAIN PAN OUTLET TO AN APPROVED | | | PLACE OF DISPOSAL. CONDENSATE SHALL NOT DISCHARGE INTO | | | A STREET, ALLEY OR OTHER AREAS SO AS TO CAUSE A | | | NUISANCE IN ACCORDANCE WITH FBCM 307.2.1. | | | | | | 4. SHOW MEANS OF AUXILIARY OR SECONDARY DRAIN | | | PROTECTION. A SECONDARY DRAIN OR AUXILIARY DRAIN PAN | | | SHALL BE REQUIRED FOR EACH COOLING OR EVAPORATOR COIL | | | WHERE DAMAGE TO ANY BUILDING COMPONENTS WILL OCCUR AS A | | | RESULT OF OVERFLOW FROM THE EQUIPMENT DRAIN PAN OR | | | STOPPAGE IN THE CONDENSATE DRAIN PIPING IN ACCORDANCE | | | WITH FBCM 307.2.3. | | | | | | 5. PROVIDE OUTSIDE AIR CALCULATIONS SHOWING THE | | | OCCUPANCY CLASSIFICATION, OCCUPANT LOAD, OUTSIDE AIR | | | PROVIDED AND OUTSIDE AIR REQUIRED FOR EACH SPACE OF THE | | | BUILDING IN ACCORDANCE WITH FBCM 403.3. | | | | | | 6. PROVIDE A COMPLETE EQUIPMENT SCHEDULE FOR A/C AND | | | EXHAUST EQUIPMENT WHICH SHOWS ALL REQUIRED NAMEPLATE | | | INFORMATION, ENERGY EFFICIENCY RATING OF THE APPLIANCES | | | AND AIR MOVED (IN CFM) IN ACCORDANCE WITH FBCM 301.2, | | | 301.6, 403.3, 601.4, 603.1. | | | | | | 7. PROVIDE AN AIR BALANCE SCHEDULE SHOWING THE SPACE TO | | | BE PRESSURIZED WITH RESPECT TO THE OUTDOORS IN | | | ACCORDANCE WITH FBCB 13-409.1.ABC.2 | | | | | | 8. SHOW THE SIZE AND LOCATION OF ALL OUTSIDE AIR AND | | | EXHAUST OPENINGS IN THE EXTERIOR OF THE BUILDING TO | | | DEMONSTRATE COMPLIANCE WITH FBCM 401.5 AND 401.6. A | | | SITE PLAN IS ALSO REQUIRED TO DETERMINE COMPLIANCE WITH | | | THESE SECTIONS. | | | | | | 9. SHEET MP HAS A HAND-WRITTEN NOTE INDICATING A | | | "SCREENED AUTOMATIC LOUVER." WHAT IS THE PURPOSE OF | | | THIS LOUVER? HOW AND WHY IS IT AUTOMATED? WHAT TYPE OF | | | LOUVER IS BEING USED? LOUVERS ARE CLASSIFIED AS PANEL | | | WALLS IN ACCORDANCE WITH FAC RULE 9B-72. PROVIDE | | | PRODUCT APPROVAL FOR ALL OUTDOOR LOUVERS IN ACCORDANCE | | | WITH THIS RULE AND FBCB SECTION 1609. ALSO, PLANS SHALL | | | NOT BE MODIFIED OR AMENDED BY HAND OR BY ANYONE OTHER | | | THAN THE DESIGNER OF RECORD IN ACCORDANCE WITH F.S. 471 | | | AND FAC RULE 61G15. | | | | | | 10. WHAT TYPE OF MATERIALS ARE THE A/C CLOSET LOUVERED | | | DOORS CONSTRUCTED? THESE A/C CLOSETS APPEAR TO BE | | | DESIGNED TO FUNCTION AS RETURN AIR PLENUMS. MATERIALS | | | EXPOSED WITHIN PLENUMS SHALL BE NONCOMBUSTIBLE OR SHALL | | | HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 25 AND A | | | SMOKE-DEVELOPED INDEX OF NOT MORE THAN 50 WHEN TESTED | | | IN ACCORDANCE WITH ASTM E 84 PER FBCM 602.2.1. | | | | | | 11. NO INFORMATION COULD BE FOUND ON PLANS REGARDING | | | THE INSTALLATION OF THE OUTDOOR CONDENSING UNITS. | | | PROVIDE INSTALLATION DETAILS AS WELL AS LOCATIONS ON | | | PLANS SHOWING COMPLIANCE WITH FBCM 301.13 FOR WIND | | | RESISTANCE, SECTIONS 303, 304 AND 306. | | | | | | 12. IF THE AIR HANDLERS ARE CAPABLE OF PRODUCING MORE | | | THAN 2,000 CFM, COMPLIANCE WITH FBCM 606.2 IS REQUIRED. | | | SHOW COMPLIANCE BY PROVIDING SMOKE DETECTORS WITH | | | AUDIBLE AND VISIBLE NOTIFICATION DEVICES OR PROVIDE | | | MANUFACTURER'S SUBMITTAL DATA SHOWING THESE UNITS ARE | | | NOT CAPABLE OF PRODUCING MORE THAN 2,000 CFM. | | | | | | 13. THE ENERGY CODE COMPLIANCE FORM SHALL BE SIGNED AND | | | SEALED BY THE PREPARER IN ACCORDANCE WITH FBCB | | | 13-103.1.1 AND FBCB 13-103.2. | | | | | | 14. PAGE 2 OF THE ENERGY CODE COMPLIANCE FORM REQUIRES | | | THAT THE INPUT REPORT BE SUBMITTED WITH THE COMPLIANCE | | | REPORT. SEE "IMPORTANT NOTE" ON THAT PAGE. NO SUCH | | | REPORT WAS PROVIDED. THE ENERGY CALCULATIONS CAN NOT BE | | | REVIEWED WITHOUT THE INPUT REPORT AND THEREFORE ARE NOT | | | BEING REVIEWED AT THIS TIME. | | | | | | 15. COOLING LOAD CALCULATIONS SHALL BE PROVIDED AND | | | APPENDED TO THE ENERGY CODE COMPLIANCE FORM IN | | | ACCORDANCE WITH FBCB 13-407.1 ABC.1. | | | | | | 16. NOTE: PLEASE BE AWARE THAT DUE TO THE LARGE AMOUNT | | | OF MISSING INFORMATION, THAT A THOROUGH REVIEW OF THE | | | PLANS CAN NOT BE PERFORMED AT THIS TIME. NEW COMMENTS | | | ARE LIKELY ONCE PLANS ARE RESUBMITTED WITH MORE | | | COMPLETE INFORMATION. IT IS NOT POSSIBLE TO MAKE A | | | COMPLETE LIST OF ALL MISSING ITEMS AND POSSIBLE CODE | | | VIOLATIONS. | | | | | | 17. NOTE: AS THIS PLAN WAS NOT SUBMITTED UNDER THE DCA | | | MODULAR BUILDING PROGRAM, THIS MODULAR BUILDING MAY NOT | | | BE DELIVERED WITH ANY ELEMENTS OF "CLOSED | | | CONSTRUCTION." ALL STRUCTURAL, BUILDING ENVELOPE, | | | MECHANICAL, ELECTRICAL AND PLUMBING SYSTEMS AND | | | COMPONENTS MUST REMAIN EXPOSED FOR COMPLETE ROUGH | | | INSPECTIONS AS REQUIRED IN ACCORDANCE WITH FBCB SECTION | | | 109. ANY PORTIONS THAT DO NOT COMPLY WITH THE | | | REQUIREMENTS OF THE CODE SHALL BE CORRECTED AND SUCH | | | PORTION SHALL NOT BE COVERED OR CONCEALED UNTIL | | | AUTHORIZED BY THE BUILDING OFFICIAL IN ACCORDANCE WITH | | | FBCB 109.6. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
N |
Date |
2008-10-22 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-10-22 |
Time |
10:16 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-10-22 |
Time |
10:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2008-09-10 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-09-10 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-09-10 |
Time |
12:41 |
Sent To |
|
|
| Notes |
| 2008-09-10 14:17:43 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 BUILDING | | | FBC-2004 CHAPTER 1 | | | FBC-2004 CHAPTER 11 | | | | | | ****FROM PREVIOUS REVIEW: | | | | | | 1. A SITE PLAN OR SURVEY IS REQUIRED. SHOW THE LOCATION | | | OF THE WATER SOURCE, (METER), RPZV BACKFLOW, SEWER | | | LATERAL, BUILDING SEWER & WATER SERVICE. SECTION | | | 106.1.2. | | | ****NO RESPONSE, COMMENT NOT ADDRESSED. ALSO SHOW THE | | | LOCATION OF THE MODULAR BUILDING ON THE SITE PLAN. | | | | | | 2. N/A | | | 3. N/A | | | 4. N/A | | | 5. N/A | | | 6. N/A | | | 7. N/A | | | 8. N/A | | | 9. N/A | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | ****NO RESPONSE COMMENT NOT ADDRESSED. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2008-08-06 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-08-06 |
Time |
09:54 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-08-06 |
Time |
09:54 |
Sent To |
|
|
| Notes |
| 2008-08-06 10:56:57 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 BUILDING | | | FBC-2004 CHAPTER 1 | | | FBC-2004 CHAPTER 11 | | | | | | 1. A SITE PLAN OR SURVEY IS REQUIRED. SHOW THE LOCATION | | | OF THE WATER SOURCE, (METER), RPZV BACKFLOW, SEWER | | | LATERAL, BUILDING SEWER & WATER SERVICE. SECTION | | | 106.1.2. | | | | | | 2. INDICATE THE OCCUPANCY OF THE BUILDING. SECTION | | | 106.3.5.1.1(2). THIS WILL DETERMINE THE REQUIRED | | | FIXTURES. TABLES 1004.1.2 & 403.1. | | | | | | 3. SUBMIT DETAILS FOR THE MEN'S & WOMEN'S TOILET ROOMS | | | SHOWING COMPLIANCE WITH THE FOLLOWING: | | | ___FOR W/C'S | | | A. 11-4.16.2 CLEAR FLOOR SPACE | | | B. 11-4.16.6 DISPENSERS | | | ___FOR URINALS | | | A. 11-4.18.3 CLEAR FLOOR SPACE | | | B. 11-4.18.4 FLUSH CONTROLS | | | ___FOR LAVS | | | A. 11-4.19.3 CLEAR FLOOR SPACE | | | ___FOR STALLS | | | A. 11-4.17.3 (FIG. 30E) - SHOWN AS 5'11" WIDE. AS | | | CONFIGURED A MINIMUM 7'1" WIDTH IS REQUIRED FOR THE | | | ACCESSIBLE STALL. | | | | | | 4. SHT FP1 INDICATE THE WATER CLOSETS TO BE 1'6" OFF | | | THE WALL TO THE CENTERLINE OF THE FIXTURE, (FIG 28), | | | AND THE LAV TO THE MIN. 15" OFF THE WALL TO THE | | | CENTERLINE OF THE FIXTURE TO BE CENTERED ON THE 30" | | | WIDTH OF THE REQUIRED CLEAR FLOOR SPACE. | | | | | | 5. SUBMIT A DETAIL FOR THE SINK IN THE UTILITY ROOM. | | | SHOW COMPLIANCE WITH THE FOLLOWING: | | | A. 11-4.24.5 CLEAR FLOOR SPACE. FORWARD APPROACH IS | | | REQUIRED. CABINET DOORS ARE NOT APPROVED IN THE CLEAR | | | FLOOR SPACE. | | | | | | 6. SHT FP2 SUBMIT A HORIZONTAL BUILDING DRAIN ISOMETRIC | | | RISER DIAGRAM SHOWING ALL PIPE SIZES, CLEANOUTS & | | | INDICATED THE DRAINAGE FIXTURE UNITS AS THEY ACCUMULATE | | | IN THE SYSTEM. SECTIONS 106.3.5.1.3 , 708 & 709.1. | | | | | | 7. SHT FP2 NO RISER SUBMITTED FOR THE DRINKING | | | FOUNTAINS. PLEASE SUBMIT. SECTION 106.3.5.1.3. | | | | | | 8. SHT FP2 WATER SUPPLY RISER DIAGRAM. WATER HAMMER | | | ARRESTORS ARE REQUIRED AT THE ICE MACHINE AND AT EACH | | | REF. SECTION 604.9. -- A FULL OPEN VALVE IS REQUIRED ON | | | THE SUPPLY LINE TO THE WATER HEATER. SECTION 606.1(7). | | | -- A FULL OPEN VALVE IS REQUIRED ON THE WATER | | | DISTRIBUTION SUPPLY PIPE AT THE ENTRANCE TO THE | | | BUILDING. SECTION 606.1(2). -- SHUT OFF VALVES ARE | | | REQUIRED ON THE SUPPLY LINES TO THE HOSE BIBBS. SECTION | | | 606.2(2). | | | | | | 9. SHT FP2 RISER FOR THE SINKS IS MISLABELED AS LAVS | | | AND DOES NOT REFLECT THE FLOOR PLAN. SINKS ARE ON | | | DIFFERENT SIDES OF THE WALL. RISER SHOWS THEM ON THE | | | SAME SIDE OF THE WALL. PLEASE CORRELATE. SECTION | | | 106.1.1. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2008-10-14 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2008-10-14 |
Time |
21:08 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2008-10-14 |
Time |
21:08 |
Sent To |
|
|
| Notes |
| 2008-10-14 21:09:06 | ***PROVISOS*** | | | | | | 1) THIS APPROVAL IS ONLY VALID FOR THE INSTALLATION OF | | | THE MODULAR BUILDING. | | | | | | 2) PRIOR TO THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY | | | FOR THE BUILDING, THE FOLLOWING ITEMS SHALL BE | | | COMPLETED: | | | | | | 2A) ALL SITE WORK (PERMIT #08080158) INCLUDING | | | LANDSCAPING, SHALL BE INSTALLED. A LANDSCAPE INSPECTION | | | SHALL BE REQUESTED AND PASSED BY THE CITY'S LANDSCAPE | | | PLANNER (ROBERT KUSSNER). | | | | | | 2B) PURSUANT TO A MEETING WITH THE OWNER ON SEPTEMBER | | | 22, 2008, AN ON-SITE INSPECTION SHALL BE SCHEDULED WITH | | | THE PROJECT PLANNER (JOHN ROACH) BY THE OWNER AND/OR | | | CONTRACTOR. SUCH INSPECTION SHALL INCLUDE THE AESTHETIC | | | APPEARANCE OF THE STRUCTURE, INCLUDING ITS | | | COMPATIBILITY WITH THE REMAINDER OF THE DEVELOPMENT AND | | | THE ADJACENT PROPERTIES. ANY IMPROVEMENTS REQUIRED AS | | | PART OF THIS INSPECTION SHALL BE COMPLETED IN | | | ACCORDANCE WITH A AGREED-UPON SCHEDULE. | | | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER, | | | AT (561) 822-1435. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2008-09-24 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2008-09-24 |
Time |
20:14 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2008-09-24 |
Time |
20:14 |
Sent To |
|
|
| Notes |
| 2008-09-24 20:23:11 | ***PROVISOS*** | | | | | | 1) THIS ZONING APPROVAL IS ONLY VALID FOR THE | | | INSTALLATION OF THE MODULAR BUILDING. | | | | | | 2) PRIOR TO THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY | | | FOR THE BUILDING, THE FOLLOWING ITEMS SHALL BE | | | COMPLETED: | | | | | | 2A) ALL SITE WORK, AS APPROVED BY PERMIT #08080158, | | | INCLUDING LANDSCAPING, SHALL BE INSTALLED. A LANDSCAPE | | | INSPECTION SHALL BE REQUESTED AND PASSED BY THE CITY'S | | | LANDSCAPE PLANNER (ROBERT KUSSNER). | | | | | | 2B) PURSUANT TO A MEETING WITH THE OWNER ON SEPTEMBER | | | 22, 2008, AN ON-SITE INSPECTION SHALL BE SCHEDULED WITH | | | THE PROJECT PLANNER (JOHN ROACH) BY THE OWNER AND/OR | | | CONTRACTOR. SUCH INSPECTION SHALL INCLUDE THE AESTHETIC | | | APPEARANCE OF THE STRUCTURE, INCLUDING ITS | | | COMPATIBILITY WITH THE REMAINDER OF THE DEVELOPMENT AND | | | THE ADJACENT PROPERTIES. ANY IMPROVEMENTS REQUIRED AS | | | PART OF THIS INSPECTION SHALL BE COMPLETED IN | | | ACCORDANCE WITH A AGREED-UPON SCHEDULE. | | | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER, | | | AT (561) 822-1435. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2008-08-08 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2008-08-08 |
Time |
13:53 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2008-08-08 |
Time |
13:53 |
Sent To |
|
|
| Notes |
| 2008-08-08 14:06:57 | ***FAILED*** | | | | | | 1) TWO (2) COPIES OF A SITE PLAN SHALL BE PROVIDED | | | SHOWING THE LOCATION OF THE PROPOSED MODULAR | | | BUILDINGS. | | | | | | 2) TWO (2) COPIES OF A CURRENT/ACCURATE SURVEY SHALL BE | | | PROVIDED. | | | | | | 3) AS THE PROPERTY IS LOCATED WITH A PLANNED | | | DEVELOPMENT (PD), ADDITIONAL ARCHITECTURAL ELEMENTS | | | SHALL BE PROVIDED ON THE ELEVATION TO ENSURE THAT THE | | | DESIGN IS CONSISTENT WITH THE REMAINDER OF DEVELOPMENT, | | | AS WELL AS PRESENTS A AESTHETIC APPEARACE TO/FROM | | | ADJACENT PROPERTIES.THE ELEVATIONS APPEAR TO BE | | | NOTHING LIKE WHAT WAS SUBMITTED AS A CONCEPTUAL DURING | | | THE SITE PLAN REVIEW PROCESS.PLEASE PROVIDE | | | ADDITIONAL ARCHITECTURAL FEATURES AND DESIGN ELEMENTS | | | TO IMPROVE THE ARCHITECTURE OF THE BUILDING. | | | | | | 4) FYI....THE PERMIT FOR THE MODULAR BUILDINGS WILL BE | | | SUBJECT TO THE ISSUANCE OF A PERMIT FOR THE REMAINDER | | | OF THE SITE IMPROVEMENTS (I.E. PARKING LOT, | | | LANDSCAPING, ETC.).NO CERTIFICATE OF OCCUPANCY (CO) | | | WILL BE ISSUED UNTIL THESE IMPROVEMENTS ARE INSTALLED. | | | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER, | | | AT (561) 822-1435. |
|
|
|