Plan Review Details - Permit 08070794
| Plan Review Stops For Permit 08070794 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2008-07-31 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2008-07-31 |
Time |
10:26 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2008-07-31 |
Time |
10:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-07-30 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2008-07-30 |
Time |
13:29 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2008-07-30 |
Time |
11:04 |
Sent To |
PC |
|
| Notes |
| 2008-07-30 13:44:17 | RESIDENTIAL (R3) WINDOWS AND SHUTTERS BUILDING REVIEW | | | CHECKLIST. | | | REVIEW UNDER FBC 2004 WITH 2007 REVISIONS. | | | | | | 1- NEED RECORDED NOTICE OF COMMENCEMENT AS REQUIRED BY | | | SEC. 713.13 FLORIDA STATUTE. | | | | | | 2-SINGLE HUNG NOA 07-0521.06 EXPIRED ON JULY 11, | | | 2008. NEED TO PROVIDE CURRENT PRODUCT APPROVAL(2 | | | COPIES) AS REQUIRED BY DCA RULE 9B-72. | | | | | | 3- CLARIFY SHUTTER SPAN SIZE SHOWN ON COLUMN 6 OF | | | INSTALLATION SCHEDULE SUBMITTED.EG: OPENING #1 IS | | | 72" WIDE AND SHUTTERS ARE INSTALLED HORIZONTALLY. | | | WHAT'S THE EDGE DISTANCE BEING CONSIDERED IF THE PANEL | | | IS 84" LONG? . THIS APPLIES TO ALL OPENINGS.ANCHORS | | | ARE TO BE ATTACHED DIRECTLY TO THE WOOD FRAMING, NOT TO | | | THE PLYWOOD SHEATHING. | | | | | | 4- ANCHOR SPACING SHOWN ON THE INSTALLATION SCHEDULE | | | CAN'T BE 13". SEESHUTTER CROSS SECTION ON SHEET 1 OF | | | 5. SHUTTER MOUNTING HOLES ARE SPACED AT 12 1/2" O.C.. | | | REVISE AS REQUIRED. | | | | | | 5- PERMIT VALUATION DECLARED IN THE PERMIT APPLICATION | | | IS TOO LOW. SEC. 108.3 CITY AMENDMENTS TO FBC 2004.A | | | VALUE OF $3,700 IS TOO LOW FOR REPLACEMENT OF 26 | | | WINDOWS, 9 MULLIONS AND INSTALLATION OF STORM SHUTTERS | | | ON EACH OPENING. UPDATE VALUATION AS REQUIRED TO | | | REFLECT COMPLETE SCOPE OF WORK. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2008-07-28 |
|
|
Cont ID |
|
| Sent By |
ssherman |
Date |
2008-07-28 |
Time |
14:26 |
Rev Time |
0.00 |
| Received By |
ssherman |
Date |
2008-07-28 |
Time |
14:26 |
Sent To |
|
|
| Notes |
| 2008-07-28 14:26:36 | HISTORIC APPROVAL PER GALINA JUDGE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-07-30 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2008-07-30 |
Time |
13:49 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2008-07-30 |
Time |
11:04 |
Sent To |
|
|
| Notes |
|
|
|