| Plan Review Stops For Permit 08070710 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2009-05-08 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2009-05-08 |
Time |
15:01 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2009-05-08 |
Time |
15:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2008-12-26 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-12-26 |
Time |
10:17 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-12-26 |
Time |
10:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2008-12-08 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-12-08 |
Time |
10:18 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-12-08 |
Time |
10:18 |
Sent To |
|
|
| Notes |
| 2008-12-08 10:17:05 | BUILDING PLAN REVIEW | | | PERMIT: 08070710 | | | ADD: 480 HIBISCUS ST. #103 | | | CONT: THE TOWER GROUP | | | TEL: (954)476-3200 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 12-8-08 | | | REVIEW: 2ND | | | ACTION: DENIED | | | | | | 1) OK | | | | | | 2) NOTE: 713.13(6) THE POSTING OF THE NOTICE OF | | | COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE THE FIRST | | | INSPECTION. | | | | | | 3) OK | | | | | | **THE SHOP DRAWING STAMP SHALL BE ON THE FRONT OF EACH | | | SHEET NOT THE BACK.** | | | 4) DUE TO THE FACT THAT THE BASE BUILDING DOES NOT HAVE | | | A CERTIFICATE OF OCCUPANCY, ALL PROJECTS FOR TENANT | | | BUILD OUT PERMITTED BEFORE THE CO OF THE BASE BUILDING | | | SHALL HAVE A REVIEW STAMP AND THE SIGNATURE FROM THE | | | DESIGNER OF RECORD OF THE BASE BUILDING ON EACH SHEET. | | | THE BASE BUILDING DESIGNERS IS RESPONSIBLE FOR THE | | | BUILDING UNTIL IT IS CO. FLORIDA STATUTES 471 AND 481. | | | THE REVIEW STAMP IS MISSING ON PLANS. | | | | | | 5) OK | | | 7) OK | | | 8) OK | | | NEW: | | | A) OK | | | B) OK | | | C) OK | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | (561)805-6726 | | | [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2008-11-07 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-11-07 |
Time |
07:52 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-11-07 |
Time |
07:52 |
Sent To |
|
|
| Notes |
| 2008-11-07 07:49:42 | BUILDING PLAN REVIEW | | | PERMIT: 08070710 | | | ADD: 480 HIBISCUS ST. #103 | | | CONT: THE TOWER GROUP | | | TEL: (954)476-3200 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 11-7-08 | | | REVIEW: 2ND | | | ACTION: DENIED | | | | | | 1) OK | | | | | | 2) NOTE: 713.13(6) THE POSTING OF THE NOTICE OF | | | COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE THE FIRST | | | INSPECTION. | | | | | | ** PARTIALY ADDRESSED. PLEASE READ THE NOTE BELOW AND | | | SUPPLY ALL THE INFORMATION REQUESTED.** | | | 3) INDICATE THE OCCUPANT LOAD OF THE SPACE PER TABLE | | | 1004.1.2. THE OCCUPANT LOAD OF THE MEZZANINE SHALL ALSO | | | BE INDICATED; STATE THE USE OF THE MEZZANINE AND THE | | | LIVE LOAD OF THE FLOOR PER FBC 1603.3 AND 1603.4. | | | PLEASE SEE TABLE 1607.1 FOR ADDITIONAL LOAD INFORMATION | | | FOR THE UNIFORM AND CONCENTRATED LOAD. | | | | | | **NOT ADDREDDED ON THE PLANS** | | | 4) DUE TO THE FACT THAT THE BASE BUILDING DOES NOT HAVE | | | A CERTIFICATE OF OCCUPANCY, ALL PROJECTS FOR TENANT | | | BUILD OUT PERMITTED BEFORE THE CO OF THE BASE BUILDING | | | SHALL HAVE A REVIEW STAMP AND THE SIGNATURE FROM THE | | | DESIGNER OF RECORD OF THE BASE BUILDING ON EACH SHEET. | | | THE BASE BUILDING DESIGNERS IS RESPONSIBLE FOR THE | | | BUILDING UNTIL IT IS CO. FLORIDA STATUTES 471 AND 481. | | | THE REVIEW STAMP IS MISSING ON PLANS. | | | | | | ** RESPONSE NOTED, HOWEVER IF THIS IS NEW CONSTRUCTION | | | TO A SPACE OR BUILDING WHICH HAS NOT RECEIVE A | | | CERTIFICATE OF OCCUPANCY, AN ALTERATION LEVEL IS NOT | | | RREQUIRED. AT THIS TIME OF REVIEW A CERTIFICATE OF | | | OCCUPANCY IS NOT ISSUED TO THIS BUILDING.** | | | 5) THE DRAWING INDICATES ALTERATION LEVEL 3 WHICH MEANS | | | THE WORK IN THE AREA EXCEEDS 50 PERCENT OF THE | | | AGGREGATE AREA OF THE BUILDING AND IS MADE WITHIN A | | | TWELVE MONTH PERIOD; FBC(EXISTING) 305.1. IS THIS THE | | | CASE FOR THIS PROJECT? IF NOT PLEASE SEE SECTION 304 OF | | | THE FBC (EXISTING) ALTERATION LEVEL 2. | | | | | | 7) OK | | | 8) OK | | | | | | NEW: | | | A) PROVIDE A DOOR SCHEDULE SHOWING THE TYPE AND SIZE OF | | | DOORS TO BE INSTALLED AT THEIR RESPECTIVE LOCATION | | | ALONG WITH THE INTERIOR FINISH SCHEDULE THE SHOW ALL | | | WALL FINISHES. SHEET A.2 SHOWS TWO SINGLE HUNG DOORS | | | ACCORDING TO DETAIL #3, HOWEVER, THERE ARE TWO DETAILS | | | REFERENCING THE #3. ON SHEET M1 THE DOORS ARE SHOWN AS | | | DOUBLE SWING DOORS. CLARIFY. THE DETAIL FOR THE DRYWALL | | | CEILING ON THE FIRST FLOOR IS MISSING FROM THE PLANS. | | | | | | B) SHEET A.4 NOTE #10 INDICATES THE FINISH DRYWALL TO | | | BE FINISHED WITH ENAMEL PAINT: THEN REFERS TO FINISH | | | SCHEDULE WHICH WAS NOT SUBMITTED. FBC 1210.2 WALL | | | WITHIN 2 FEET OF URINALS AND WATER CLOSETS SHALL HAVE A | | | SMOOTH, HARD, NONABSORBENT SURFACE, TO A HEIGHT OF 4 | | | FEET ABOVE THE FLOOR. SHOW COMPLIANCE. | | | | | | C) SHEET A.2. PROVIDE DETAIL DRAWINGS SHOWING THE | | | STRUCTURAL SUPPORT FOR THE SUSPENDED WOOD CEILING AND | | | THE SUSPENDED TRACK LIGHTING. ADDITIONAL INFORMATION IS | | | REQUIRED 106.1.2* | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | (561)805-6726 | | | [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-08-15 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-08-15 |
Time |
16:20 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-08-15 |
Time |
14:45 |
Sent To |
|
|
| Notes |
| 2008-08-15 16:20:54 | BUILDING PLAN REVIEW | | | PERMIT: 08070710 | | | ADD: 480 HIBISCUS ST. #103 | | | CONT: THE TOWER GROUP | | | TEL: (954)476-3200 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 8-15-08 | | | REVIEW: 1ST | | | ACTION: DENIED | | | | | | 1) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE & REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 2) FL S S 713.13 NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT. NOTE: 713.13(2) IF THE | | | WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS NOT | | | ACTUALLY COMMENCED WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) | | | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE | | | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | | | 3) INDICATE THE OCCUPANT LOAD OF THE SPACE PER TABLE | | | 1004.1.2. THE OCCUPANT LOAD OF THE MEZZANINE SHALL ALSO | | | BE INDICATED; STATE THE USE OF THE MEZZANINE AND THE | | | LIVE LOAD OF THE FLOOR PER FBC 1603.3 AND 1603.4. | | | PLEASE SEE TABLE 1607.1 FOR ADDITIONAL LOAD INFORMATION | | | FOR THE UNIFORM AND CONCENTRATED LOAD. | | | | | | 4) DUE TO THE FACT THAT THE BASE BUILDING DOES NOT HAVE | | | A CERTIFICATE OF OCCUPANCY, ALL PROJECTS FOR TENANT | | | BUILD OUT PERMITTED BEFORE THE CO OF THE BASE BUILDING | | | SHALL HAVE A REVIEW STAMP AND THE SIGNATURE FROM THE | | | DESIGNER OF RECORD OF THE BASE BUILDING ON EACH SHEET. | | | THE BASE BUILDING DESIGNERS IS RESPONSIBLE FOR THE | | | BUILDING UNTIL IT IS CO. FLORIDA STATUTES 471 AND 481. | | | | | | 5) THE DRAWING INDICATES ALTERATION LEVEL 3 WHICH MEANS | | | THE WORK IN THE AREA EXCEEDS 50 PERCENT OF THE | | | AGGREGATE AREA OF THE BUILDING AND IS MADE WITHIN A | | | TWELVE MONTH PERIOD; FBC(EXISTING) 305.1. IS THIS THE | | | CASE FOR THIS PROJECT? IF NOT PLEASE SEE SECTION 304 OF | | | THE FBC (EXISTING) ALTERATION LEVEL 2. | | | | | | 7) FBC 1013.3 (EXCEPTION #5) SHOW THE COMMON PATH OF | | | EGRESS TRAVEL WHICH SHALL BE 100 FEET IN BUILDINGS WITH | | | AN AUTOMATIC SPRINKLER SYSTEM INSTALLED THROUGHOUT. | | | | | | 8) FBC 1009.5 ALL STAIRS SHALL BE BUILT OF MATERIALS | | | CONSISTENT WITH THE CONSTRUCTION TYPE OF THE BUILDING | | | WHICH IS TYPE IB. ONLY THE HANDRAILS CAN BE CONSTRUCTED | | | OF WOOD. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | (561)805-6726 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
P |
Date |
2009-07-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-07-14 |
Time |
11:03 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-07-14 |
Time |
11:03 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2009-05-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-05-15 |
Time |
08:39 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-05-15 |
Time |
08:39 |
Sent To |
PC |
|
| Notes |
| 2009-05-15 08:40:49 | REDLINED PLANS. | | | THERE IS NO REV #6 AS SHOWN IN TITLE BLOCKS. | | | | | | THE EM LT FIXTURE SHOWN IN SPACE WHICH WAS FROM | | | ORIGINAL BASE BUILDING SHELL SPACE IS TO BE DELETED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2009-05-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-05-07 |
Time |
08:43 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-05-07 |
Time |
08:43 |
Sent To |
|
|
| Notes |
| 2009-05-07 08:44:04 | **DENIED PLANS** | | | | | | | | | | | | 1) NOTE: PLEASE SEE THE TITLE BLOCKS WHICH INDICATE A | | | REVISION #6 HOWEVER THE PLANS ARE NOT LABELED WITH ANY | | | REVISION #6. | | | PLEASE COORDINATE ALL PLANS AND REVISIONS. | | | FBC 106.1.1, 106..5 FOR CLARITY AND COORDINATION OF | | | RECORD PLANS. | | | NEC 2005 AS THERE ARE REVISIONS TO PLANS WHICH ARE NOT | | | IDENTIFIED. SEE COMMENT #2. | | | | | | 2) NOTE: PLANS NOW INDICATE AN EXISTING EMERGENCY LIGHT | | | FIXTURE TO REMAIN. PLEASE INDICATE WHERE THE | | | DISCONNECTING MEANS OF THIS BASE BUILDING BRANCH | | | CIRCUIT IS LOCATED. IT IS BEING *ASSUMED* THIS IS PART | | | OF THE BASE BUILDING CIRCUIT AS IT WAS REQUIRED TO BE | | | INSTALLED BECAUSE IT WAS A SHELL SPACE ON ORIGINAL | | | PLANS. THE FIXTURES AND WIRING WHICH WERE INSTALLED FOR | | | SHELL SPACES WERE TO BE REMOVED OR BE CONTROLLED FROM | | | TENANT SPACE ELECTRICAL SYSTEMS. IS THIS ELECTRICAL IN | | | ONE TENANT SPACE FED FROM TWO COMPLETELY SEPARATE | | | SERVICES? | | | THIS IS A HAZARD IF THIS IS INDEED HOW THIS IS | | | INSTALLED AND WIRED. | | | PLEASE REVISE PLANS AND CLEAR UP WHAT THE DESIGN IS | | | BEING PROPOSED. AS NOTED ABOVE, THE EMERGENCY LIGHT | | | FIXTURES PLANS ON ORIGINAL SHELL TENANT SPACES WERE | | | REQUIRED ONLY TO BE FED FROM BASE BUILDING UNTIL | | | SEPARATE TENANTS WHICH ARE FED FROM A SEPARATE SERVICE | | | ARE BUILT OUT. | | | 240.24B, 210.25 | | | | | | ** IMPORTANT ** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED | | | INTO TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2008-12-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-12-26 |
Time |
11:51 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-12-26 |
Time |
11:51 |
Sent To |
|
|
| Notes |
| 2008-12-26 11:51:29 | ** PROVISO** | | | | | | 1) NOTE: THE FIXTURE TYPES AND NUMBER OF FIXTURES HAVE | | | NOW BEEN REVISED. THE LIGHTING CALCULATION TABLE NOW | | | INDICATE AN ADDITIONAL ALLOWANCE FOR DISPLAY AREAS. | | | HOWEVER PLEASE SEE 13-415.2.B.2. THE FOLLOWING IS | | | EXTRACTED DIRECTLY FROM THE CODE. THIS IS NOT A RETAIL | | | OCCUPANCY. | | | | | | ** | | | FOR LIGHTING EQUIPMENT INSTALLED IN RETAIL SPACES THAT | | | IS SPECIFICALLY DESIGNED AND DIRECTED TO HIGHLIGHT | | | MERCHANDISE, PROVIDED THAT THE ADDITIONAL LIGHTING | | | POWER SHALL NOT EXCEED: | | | (1) 1.6 WATTS PER SQUARE FOOT TIMES THE AREA OF | | | SPECIFIC DISPLAY OR | | | ** | | | | | | ** PLEASE REVISE TO REMOVE ADDITIONAL ALLOWANCES. | | | | | | PLEASE SEE THE FIXTURE LEGEND WHICH GIVES THE FIXTURE | | | COUNT AND WATTAGES. THERE ARE MORE TYPE *C* FIXTURES ON | | | PLANS THAN ON TABLE. THE TOTAL ALLOWANCE BASED ON THIS | | | SPACE AND OCCUPANCY IS 2596. THE DESIGN WATTAGE WHICH | | | IS BASED ON FIXTURES ON PLANS AND WATTAGES SHOWN IS | | | 2584. | | | AS THIS DOES NOT EXCEED ALLOWANCE PER THE FBC A PROVISO | | | TO REVISE PLANS AT LATER DATE IS GIVEN. | | | ** IF THERE ARE OTHER REVISIONS PLEASE REVISE BEFORE | | | ROUGH. IF THESE BECOME THE ONLY REVISED ITEM PLEASE | | | REVISE BEFORE FINAL. | | | | | | 13-415.2,13-415.2.ABC.1.1, .1.2. ETC | | | | | | 2) NOTE: SIGN REQUIRED FOR DOORS AT TRANSFORMER | | | LOCATION. | | | | | | *ELECTRICAL ROOM/ NO STORAGE* | | | | | | OR WORDS TO THAT AFFECT. 240.24,110.26 | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2008-12-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-12-09 |
Time |
10:47 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-12-09 |
Time |
10:47 |
Sent To |
|
|
| Notes |
| 2008-12-12 08:35:11 | *** PER PREVIOUS NOTICE TO REPEAT COMMENTS FOR CODE | | | COMPLIANCE, THE CODE SECTIONS WERE REPEATED THREE OR | | | MORE TIMES. THE CODE SECTIONS FOR FBC CHAPTER 13 FOR | | | LIGHTING COMPLIANCE ALONG WITH OTHER SECTIONS WERE | | | REPEATED AND COMPLIANCE HAS STILL NOT BEEN ACHEIVED. TH | | | IS A STATUTORY REQUIREMENT AND IS REQUIRED. THIS IS NOT | | | AN OPTIONAL FEE TO BE ASSESED. THE AMOUNT OF $960 WILL | | | BE DUE. | | | ONE COPY OF ELECTRICAL PLANS WERE RETAINED BY THIS | | | OFFICE AS REQUIRED. | | 2008-12-09 10:48:20 | | | | ** DENIED 3RD REVIEW ** | | | | | | 1) NOTE: PLEASE BE SURE ALL SETS ARE PLACED TOGETHER IN | | | COMPLETE SETS WHEN RESUBMITTING. PLEASE REMOVE ANY | | | OLD/VOIDED SHEETS. | | | | | | 2) NOTE: PLANS SUBMITTED WHICH WERE REVISED ON 11/25/08 | | | ARE ACTUALLY SIGNED, DATED AND SEALED WITH A DATE OF | | | 10/25/08. THIS IS NOT POSSIBLE. | | | FS 471.025 | | | | | | 3) NOTE: PLANS SHALL CONTAIN THE * SHOP DRAWING REVIEW | | | STAMP* AND SIGNATURE OF THE BASE BUILDING DESIGNERS OF | | | RECORD ON EACH AND EVERY SHEET. THIS IS REQUIRED TO BE | | | ON THE PLANS AND NOT ON THE BACK OF THE SHEETS. RECORD | | | PLANS ARE SCANNED AND SCANNING OF THE BACK OF THE | | | SHEETS WHICH ARE *BLANK* DOES NOT SHOW ACTUAL RECORD OF | | | ANYTHING. | | | PLEASE ALSO BE SURE THESE STAMPS ARE SIGNED BY THE | | | RESPONSIBLE DESIGNER OF RECORD. THE SIGNATURES FOR BOTH | | | PERSONS AS STAMPED ARE NOT FROM THE DESIGNERS OF | | | RECORD. | | | FS481.221,471.025 | | | | | | 4) NOTE: PLEASE SEE 13-415.2, 13-415.2.ABC.1.1,.1.2 FOR | | | LIGHTING POWER ALLOWANCES. THE AMOUNT OF FIXTURES AND | | | WATTAGE ON PLANS EXCEEDS MAXIMUM ALLOWANCE UNDER THE | | | ENERGY CODE. PLEASE SEE EXAMPLES SUCH AS FIXTURE *A*. | | | THE AMOUNT OF FIXTURES ON PLANS IS GREATER THAN THE | | | AMOUNT IN THE CALCULATIONS. THIS IS ONE FIXTURE AND | | | THERE ARE OTHERS WHICH ARE OVER. THE DESIGN WATTAGE ON | | | PLANS COMES TO OVER 3000 WATTS WHEN ALLOWANCE BASED ON | | | THE 1236 SQ FT IS 2595. | | | | | | 5) NOTE: PLEASE SEE 11-4.28.3(4). PLANS NOTE THE STROBE | | | 75 FLASH RATE. THIS SHOULD BE 75CD/ OR CANDELA. THE | | | FLASH RATE IS DIFFERENT. | | | | | | 6) NOTE: PLEASE BE SURE THE SUITE OR UNIT NUMBER IS | | | LISTED ON THE TITLE BLOCKS OF EACH SHEET. THIS CAN BE | | | PRINTED ON ANY SHEETS WHICH DO NOT NEED TO BE REVISED. | | | FAC 61G1-16.004, 61G15-23.002, FBC 106.5. | | | | | | | | | | | | | | | | | | | | | **IMPORTANT** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED | | | INTO TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2008-11-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-11-10 |
Time |
11:26 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-11-10 |
Time |
11:26 |
Sent To |
|
|
| Notes |
| 2008-11-10 11:26:45 | | | | | | | | | | ** DENIED 2ND REVIEW ** | | | | | | | | | | | | 1) NOTE: SAME NOTE AS ON PREVIOUS REVIEW: | | | THE BASE BUILDING DOES NOT HAVE A CERTIFICATE OF | | | OCCUPANCY. ALL PROJECTS FOR TENANT BUILD OUT PERMITTED | | | BEFORE THE C OF O OF BASE BUILDING ARE TO CONTAIN A | | | *SHOP DRAWING* REVIEW STAMP AND SIGNATURE FROM THE BASE | | | BUILDING DESIGNERS OF RECORD ON EACH RELEVANT SHEET. | | | THE BASE BUILDING DESIGN TEAM IS RESPONSIBLE FOR THE | | | BUILDING UNTIL SUCH TIME A C OF O IS ISSUED. | | | FS 471,481 | | | | | | 2) NOTE: SAME NOTE AS ON PREVIOUS REVIEW: | | | PLEASE KNOW THAT ANY PERMITTED PROJECTS FOR BUILD OUT | | | BEFORE THE C OF O IS ISSUED ON BASE BUILDING WILL | | | REQUIRE THE FOLLOWING TO BE REVISED. | | | THE BASE BUILDING LOAD CALCULATIONS ARE REQUIRED TO BE | | | REVISED TO INDICATE AND SHOW ALL NEW KNOWN LOADS. | | | 220 | | | THE BASE BUILDING ENERGY CALCULATIONS SHALL BE REVISED | | | FROM WHAT WAS ENTERED AS *ASSUMPTIONS* ON CALCULATIONS | | | TO NEW KNOWN ENERGY USE. | | | THIS INCLUDES ALL NEW LIGHTING. | | | FBC CHAPTER 13. | | | | | | 3) NOTE: THE PLANS STILL INDICATE EXISTING RETAIL | | | HOWEVER THIS IS NOT POSSIBLE AS THE BUILDING CONTAINS | | | *SHELL* SPACES FOR FUTURE. THE PLANS NEED TO BE | | | ADJUSTED ACCORDINGLY. | | | FBC 301.1 | | | FBC 106.1.1,106.5 FOR CLARITY, COORDINATION OF RECORD | | | PLANS. | | | | | | 4) NOTE: THE SUBMITTED LIGHTING PERFORMANCE | | | CALCULATIONS ARE NOT COMPLETE AT THIS TIME. PLEASE SEE | | | THE FIXTURE LEGEND NOW SUBMITTED IS NOT YET COMPLETE. | | | AN EXAMPLE IS THE *Q* FIXTURE. THIS ONE EXAMPLE IS | | | GIVEN AS A BENEFIT. | | | PLEASE SEE SECTIONS OF CODE BELOW WHICH WERE GIVEN ON | | | PREVIOUS REVIEW. PLEASE SEE TRACK LIGHTING IN THE FBC. | | | THE CODE REQUIRES ANY LINE VOLTAGE FIXTURES TO BE | | | FIGURED AT THE MAXIMUM VA PER FIXTURE OR 30VA PER | | | LINEAR FT OF TRACK WHICH EVER IS GREATER. IF THESE ARE | | | LOW VOLTAGE TYPES THEN THE VA IS BASED ON THE MAXIMUM | | | VA OF THE TRANSFORMER. THE FIXTURE LEGEND AS SUBMITTED | | | HAS A N/A NEXT TO FIXTURE AND ASSOCIATED EQUIPMENT. | | | | | | PLEASE SUBMIT LIGHTING PERFORMANCE CALCULATIONS IN | | | COMPLIANCE WITH FBC 13-415.2, 13-415.2.ABC.1.1, .1.2. | | | | | | 5) NOTE: THE RISER SHOWS WHAT APPEARS TO BE THE | | | DISCONNECT AND TRANSFORMER WHICH WOULD BE LOCATED IN | | | THE STORAGE CLOSET ON MEZZANINE LEVEL WHICH IS NOT | | | PERMITTED. | | | THE ELECTRICAL PLANS DO NOT SHOW EITHER OF THESE TWO ON | | | MEZZANINE LEVEL AND ONLY SHOWS THE PANEL. | | | PLEASE SHOW LOCATIONS OF ALL EQUIPMENT, LABEL | | | ACCORDINGLY TO RISER AND PANEL IDENTIFICATION. | | | PLEASE SEE 240.21,450.9,450.13,450.21, 240.24 ETC | | | THIS AS SHOWN ON PLANS IS CLEARLY A STORAGE CLOSET | | | WHICH WILL CONTAIN COMBUSTIBLES AND EASILY IGNITABLE | | | MATERIALS. THIS IS A FIRE AND LIFE SAFETY HAZARD. | | | PLEASE ADJUST, RE-LOCATE ETC. | | | | | | 6) NOTE: FROM PREVIOUS REVIEW: | | | PLEASE INCLUDE THE DEVICE LOCATIONS, LEVELS, AND | | | HEIGHTS FOR ALL FIRE ALARM DEVICES FOR ADA COMPLIANCE. | | | FBC 11-4.28.1,.2 AND .3. | | | | | | 7) NOTE: PLEASE SEE 410.5, 410.6 ETC AS THE TYPE *Q* | | | FIXTURE MAY NOT BE LOCATED NEAR COMBUSTIBLES. | | | | | | 8) NOTE: PLEASE SEE NOTICE TOT FS 553.80(2)(B) IS GIVEN | | | AT THIS TIME DUE TO SOME COMMENTS BEING REPEATED . THIS | | | ONLY A NOTICE AT THIS TIME. | | | | | | | | | | | | **IMPORTANT** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED | | | INTO TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2008-08-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-08-08 |
Time |
09:42 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-08-08 |
Time |
09:42 |
Sent To |
|
|
| Notes |
| 2008-08-08 09:42:44 | | | | ** DENIED REVIEW ** | | | | | | | | | | | | 1) NOTE: THE BASE BUILDING DOES NOT HAVE A CERTIFICATE | | | OF OCCUPANCY. ALL PROJECTS FOR TENANT BUILD OUT | | | PERMITTED BEFORE THE C OF O OF BASE BUILDING ARE TO | | | CONTAIN A *SHOP DRAWING* REVIEW STAMP AND SIGNATURE | | | FROM THE BASE BUILDING DESIGNERS OF RECORD ON EACH | | | RELEVANT SHEET. | | | THE BASE BUILDING DESIGN TEAM IS RESPONSIBLE FOR THE | | | BUILDING UNTIL SUCH TIME A C OF O IS ISSUED. | | | FS 471,481 | | | | | | 2) NOTE: PLEASE KNOW THAT ANY PERMITTED PROJECTS FOR | | | BUILD OUT BEFORE THE C OF O IS ISSUED ON BASE BUILDING | | | WILL REQUIRE THE FOLLOWING TO BE REVISED. | | | THE BASE BUILDING LOAD CALCULATIONS ARE REQUIRED TO BE | | | REVISED TO INDICATE AND SHOW ALL NEW KNOWN LOADS. | | | 220 | | | THE BASE BUILDING ENERGY CALCULATIONS SHALL BE REVISED | | | FROM WHAT WAS ENTERED AS *ASSUMPTIONS* ON CALCULATIONS | | | TO NEW KNOWN ENERGY USE. | | | THIS INCLUDES ALL NEW LIGHTING. | | | FBC CHAPTER 13. | | | | | | 3) NOTE: PLEASE SUBMIT AND SHOW THE LIGHTING LEVELS IN | | | PHOTO-METRICS ON STAIRS PER NFPA-101 2003, 7.8.1.3, | | | 7.9.2.1, .2.2. | | | | | | 4) NOTE: PLEASE INDICATE ALL LIGHTING CONTROLS REQUIRED | | | PER FBC 13-415.1.ABC.1.1,.1.2 AND .1.3. | | | THE SYMBOL LEGEND DOES INDICATE SOME OCCUPANCY SENSOR | | | TYPE DEVICES HOWEVER NONE OF THIS DEVICE S IS ON PLANS. | | | IN FACT THE PLANS ONLY INDICATE STANDARD SWITCHING | | | DEVICES WHICH ARE NOT PERMITTED. | | | PLEASE PROVIDE ALL MAXIMUM TIMES ON ALL DEVICES. | | | PLEASE BE SURE TO SEE NFPA-101 7.8.1.2.2 AND FBC | | | 1006.1.2 AS ANY OCCUPANCY SENSOR FOR ANY EGRESS | | | LIGHTING SHALL BE * FAIL SAFE ON*. | | | | | | 5) NOTE: PLEASE SUBMIT LIGHTING PERFORMANCE | | | CALCULATIONS IN COMPLIANCE WITH FBC 13-415.2, | | | 13-415.2.ABC.1.1, .1.2. | | | PLEASE SUBMIT THE FIXTURE SCHEDULE/LEGEND. | | | PLEASE SEE THE SECTIONS OF THE CODE ABOVE. THE WATTAGE | | | TO BE USED IS BASED ON THE FIXTURE WATTAGE NOT THE LAMP | | | WATTAGE AS STATED ON PLANS. | | | PLEASE KNOW AS THE PLANS ARE NOT COMPLETE WITH A | | | FIXTURE LEGEND ETC SOME OF THESE ITEMS FOR CODE | | | COMPLIANCE CAN NOT BE DETERMINED AT THIS TIME. | | | | | | 6) NOTE: PLEASE PROVIDE VOLTAGE DROP PER | | | 13-413.1.ABC.1.2 FOR CU. | | | | | | 7) NOTE: PLEASE COMPLETE PANEL SCHEDULE FOR ALL | | | CIRCUITS TO SPECIFIC AREAS AND LOCATIONS. | | | 408.4 | | | | | | 8) NOTE: PLEASE COORDINATE ALL CIRCUITS. PLEASE SEE ONE | | | FOR EXAMPLE AS L-10 IS INDICATED ON PANEL SCHEDULE AS | | | *MEZZANINE* YET THIS IS ALSO SHOWN ON PLANS TO THE | | | REFRIGERATOR. | | | NO DEDICATED CIRCUIT SHOWN FOR REFRIGERATOR. | | | PLEASE SEE SOME OTHER CIRCUITS SHOWING A QUESTION MARK | | | NEXT TO THE PANEL DESIGNATION ON PLAN. | | | 408.4, 240.4, ETC | | | | | | 9) NOTE: PLEASE VERIFY RISER AS THE GUTTER IS INDICATED | | | AS RAIN TIGHT? PLEASE ALSO INDICATE THE SIZE/AMPERAGE | | | OF THE GUTTER PROVIDED. | | | PLEASE INDICATE A FLOATING NEUTRAL ON THE NEW METER AS | | | THE MAIN FOR TENANT SHOWN WILL BE AFTER A MEANS OF | | | DISCONNECT FOR SERVICE. | | | 250.24, 250.6 | | | | | | 10) NOTE: PLEASE SEE 600.5 AS THE LOAD FOR A SIGN | | | CIRCUIT IS REQUIRED TO BE FIGURED AT 1200VA. THIS WOULD | | | BE 10AMPS ON THE CIRCUIT. | | | ** | | | | | | 11) NOTE: PLEASE SEE 210.62 FOR MISSING SHOW WINDOW | | | RECEPTACLES. | | | PLEASE ALSO SEE 220.43 | | | | | | 12) NOTE: PLEASE INCLUDE LOADS FOR TRACK LIGHTING PER | | | 220.43 | | | | | | 13) NOTE: BASE BUILD OUT PLANS SHALL INCLUDE DEVICES TO | | | COMPLY WITH THE FIRE CODES, SUCH AS NFPA-1, NFPA-72 AND | | | FBC 2004 W/2007 REVISIONS. | | | PLEASE SEE FBC 11-4.28 (ALL) AND INDICATE REQUIRED | | | DEVICES ACCORDINGLY | | | | | | ** PLEASE KNOW AS THERE ARE SOME ITEMS NOT YET ON | | | DESIGN SHEETS THERE MAY VERY WELL BE NEW COMMENTS ON | | | THE FOLLOWING REVIEW WHICH CAN NOT BE MADE AT THIS | | | TIME. | | | | | | | | | | | | | | | **IMPORTANT** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | | TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
5 |
Status |
P |
Date |
2009-05-05 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2009-05-05 |
Time |
15:11 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2009-05-05 |
Time |
14:26 |
Sent To |
|
|
| Notes |
| 2009-05-05 15:11:07 | *****REVISION APPROVED***** | | | | | | | | | REVISED PLAN SHEET A.1 (OF THE SUBMITTED PLAN SET) | | | STAMPED, INITIALED, AND DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2008-12-26 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-12-26 |
Time |
14:02 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-12-26 |
Time |
14:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
F |
Date |
2008-12-10 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-12-10 |
Time |
12:04 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-12-10 |
Time |
11:34 |
Sent To |
|
|
| Notes |
| 2008-12-10 12:03:29 | *****UNSAT***** | | | | | | PLEASE BE ADVISED THAT THE BASE BUILDING DOES NOT HAVE | | | A CERTIFICATE OF OCCUPANCY | | | | | | | | | THE COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEWS HAVE | | | BEEN SATISFIED; HOWEVER THE APPROPIATE SHEETS TO BE | | | FIRE-STAMPED WHEN THE MATTER WITH THE SHOP DRAWING | | | STAMP (SEE BUILDING AND ELECTRICAL EXAMINERS' COMMENT) | | | HAS BEEN ADDRESSED. | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2008-11-12 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-11-12 |
Time |
11:38 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-11-12 |
Time |
11:38 |
Sent To |
|
|
| Notes |
| 2008-11-12 11:43:59 | ***DENIED*** | | | | | | 1) ON SHEET A.3- CAPTION 1, CLARIFY AS TO WHETHER THE | | | ADDRESS VERBAGE IS FOR BUILDING OR THE SUITE. A.3 CAN | | | NOT BE FOUND WITH INITIAL SUBMITTAL. | | | | | | 2) SHOW LAYOUT OF THE SPRINKLER HEADS FOR THE FLOOR | | | SPACE. THESE HEADS MAY BE SHOWN ON THE REFLECTED | | | CEILING PLAN. NO ATTACHED ENGINEERED SPRINKLER DRAWINGS | | | FOUND WITH THIS SUBMITTAL. | | | | | | PLANS DON'T SEEM TO CORRELATE WITH RESPONSE LETTER. | | | | | | | | | MIKE WENNERGREN, ASST. FIRE MARSHAL | | | FIRE PLAN REVIEW | | | FIRE PREVENTION (561) 804-4756 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2008-08-13 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-08-13 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-08-13 |
Time |
13:51 |
Sent To |
|
|
| Notes |
| 2008-08-13 13:59:40 | *****DENIED***** | | | | | | PLEASE BE ADVISED THAT THEBASE BUILDING DOES NOT HAVE A | | | CERTIFICATE OF OCCUPANCY | | | | | | 1. ON SHEET A.3 - CAPTION 1, CLARIFY AS TO WHETHER THE | | | ADDRESS VERBAGE IS FOR THE BUILDING OR THE SUITE. | | | | | | 2. SHOW A LAYOUT OF THE SPRINKLER HEADS FOR THE FLOOR | | | SPACE. THESE HEADS MAY BE SHOWN ON THE REFLECTED | | | CEILING PLAN. | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2009-07-01 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2009-07-01 |
Time |
08:19 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2009-07-01 |
Time |
08:19 |
Sent To |
|
|
| Notes |
| 2009-07-01 08:20:13 | SENT TO D.PALMER'S DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2009-04-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-04-29 |
Time |
14:17 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-04-29 |
Time |
14:17 |
Sent To |
|
|
| Notes |
| 2009-04-29 14:17:34 | TO B-13 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2008-12-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-12-19 |
Time |
15:44 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-12-19 |
Time |
15:44 |
Sent To |
|
|
| Notes |
| 2008-12-19 15:45:04 | TO "BOB"#10 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-12-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-12-01 |
Time |
15:25 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-12-01 |
Time |
15:25 |
Sent To |
|
|
| Notes |
| 2008-12-01 15:25:44 | TO "BOB"#3 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-11-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-11-03 |
Time |
14:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-11-03 |
Time |
14:50 |
Sent To |
|
|
| Notes |
| 2008-11-03 14:56:48 | TO "BOB"#12 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-11-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-08-20 |
Time |
14:46 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-07-28 |
Time |
11:56 |
Sent To |
|
|
| Notes |
| 2008-08-05 09:23:58 | TO "BOB"#18 | | 2008-07-28 11:57:16 | WAITING FOR "BOB" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
P |
Date |
2009-07-14 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-07-14 |
Time |
16:47 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-07-14 |
Time |
16:47 |
Sent To |
PC |
|
| Notes |
| 2009-07-14 16:47:32 | REVISED M1 DELTA 6 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2009-05-12 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-05-12 |
Time |
14:13 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-05-12 |
Time |
14:01 |
Sent To |
PC |
|
| Notes |
| 2009-05-12 14:14:15 | PAGE M-1 REVISION #5 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2008-12-29 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-12-29 |
Time |
10:39 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-12-29 |
Time |
10:38 |
Sent To |
|
|
| Notes |
| 2008-12-29 10:39:28 | OK FOR LMARTINEZ TO STAMP MECH SHEETS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2008-12-12 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-12-12 |
Time |
16:37 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-12-11 |
Time |
19:28 |
Sent To |
|
|
| Notes |
| 2008-12-12 16:37:11 | REVIEW #: 3RD | | | ACTION: DENIED | | | | | | FBC 2004 CODE FAMILY W/ 2007 SUPPLEMENTS | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | THE FOLLOWING COMMENTS ARE NUMBERED TO CORRESPOND WITH | | | PREVIOUS REVIEW COMMENTS AS WELL AS DESIGNER'S WRITTEN | | | RESPONSES FOR THE PURPOSE OF CONTINUITY. | | | | | | 1. **PARTIALLY ADDRESSED** PLEASE PLACE SHOP DRAWING | | | REVIEW STAMPS ON FRONT OF PAGES FOR RECORDS RETENTION | | | PURPOSES. THSES PLANS WILL BE DIGITIZED FOR ARCHIVING | | | AND STAMPS ON BACKS OF PAGES WILL NOT BE RECORDED. | | | ALSO, PAGE M1 CONTAINS A SHOP DRAWING REVIEW STAMP | | | DATED 10/25/08 BUT THE PLANS INDICATE THEY WERE REVISED | | | ON 11/25/08 (SAME GOES FOR ENGINEER'S SEAL AND | | | SIGNATURE). HOW IS THIS POSSIBLE? PLEASE CORRECT DATES | | | ON PLANS TO CORRESPOND WITH ACTUAL REVISION DATES. | | | | | | 2. OK | | | | | | 3. **NOT ADDRESSED** PAGE M1 DUCT TAKEOFF DETAIL: IN NO | | | CASE SHALL THE MATERIAL SUPPORTING FLEXIBLE DUCT THAT | | | IS IN DIRECT CONTACT WITH IT BE LESS THAN 1.5 INCHES | | | WIDE IN ACCORDANCE WITH FBCM 603.5.6.6. | | | | | | 4. OK | | | | | | 5. OK | | | | | | 6. **NOT ADDRESSED** PAGE M1 PLUMBING NOTE #18: THIS | | | NOTE CALLS FOR PVC O BE USED FOR THE CONDENSATE DRAIN | | | LINE. PVC MAY NOT BE USED IN THE MECHANICAL ROOM WHICH | | | ALSO SERVES AS A RETURN AIR PLENUM. MATERIALS EXPOSED | | | WITHIN PLENUMS SHALL BE NONCOMBUSTIBLE OR SHALL HAVE A | | | FLAME SPREAD INDEX OF NOT MORE THAN 25 AND A | | | SMOKE-DEVELOPED INDEX OF NOT MORE THAN 50 WHEN TESTED | | | IN ACCORDANCE WITH ASTM E 84 PER FBCM 602.2.1. | | | | | | 7. OK | | | | | | 8. **NOT ADDRESSED** PAGE A.1 SHOWS A SINGLE DOOR IN | | | MECHANICAL ROOM 204. PAGE M1 FLOOR PLAN SHOWS A | | | LOUVERED DOUBLE-DOOR AT THIS LOCATION. WHICH IS | | | CORRECT? NO DOOR SCHEDULE COULD BE FOUND IN THE | | | ARCHITECTURAL PLANS TO SHOW WHICH TYPE OF DOOR IS TO BE | | | USED AT THIS LOCATION. PLEASE SHOW THE DOOR TYPES TO | | | VERIFY THAT A LOUVERED DOOR IS BEING PROVIDED FOR | | | RETURN AIR. ALSO, THE TYPE OF DOOR SHALL MEET THE | | | REQUIREMENTS FOR A PLENUM IN ACCORDANCE WITH FBCM | | | 602.2.1. | | | | | | 9. SEE ABOVE. | | | | | | 10. OK | | | | | | 11. OK | | | | | | **NEW** THESE PLANS HAVE FAILED REVIEW FOR CODE | | | COMPLIANCE 3 TIMES. EACH TIME COMMENTS 3, 6 AND 8 ABOVE | | | HAVE BEEN REPEATED AND HAVE NOT BEEN ADDRESSED OR | | | CORRECTED ON PLANS. AS A RESULT, A FINE OF FOUR TIMES | | | THE PLAN REVIEW FEE IS BEING IMPOSED ON THIS PERMIT | | | APPLICATION IN ACCORDANCE WITH FS 553.80(2)(B). THE | | | CITY OF WEST PALM BEACH ATTRIBUTES 30% OF PERMIT FEES | | | TO PLAN REVIEW. THE PERMIT FEE IS $800. THIRTY PERCENT | | | OF THAT FEE (THE PLAN REVIEW FEE) IS $240. THE TOTAL | | | AMOUNT DUE PRIOR TO RESUBMISSION OF PLANS FOR PERMIT IS | | | $960.00. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2008-11-15 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-11-15 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-11-15 |
Time |
15:53 |
Sent To |
PC |
|
| Notes |
| 2008-11-15 15:56:30 | REVIEW #: 2ND | | | ACTION: DENIED | | | | | | FBC 2004 CODE FAMILY W/ 2007 SUPPLEMENTS | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | THE FOLLOWING COMMENTS ARE NUMBERED TO CORRESPOND WITH | | | PREVIOUS REVIEW COMMENTS AS WELL AS DESIGNER'S WRITTEN | | | RESPONSES FOR THE PURPOSE OF CONTINUITY. | | | | | | 1. THIS APPLICATION IS FOR A TENANT IMPROVEMENT IN A | | | BUILDING WHICH IS NOT YET COMPLETED. IF THIS PERMIT IS | | | TO BE ISSUED PRIOR TO C.O. OF THE BASE BUILDING, THE | | | DESIGNERS F THE BASE BUILDING SHALL PERFORM A SHOP | | | DRAWING REVIEW OF THESE PLANS AND APPROVE THEM IN | | | WRITING (SHOP DRAWING REVIEW STAMP). THIS IS TO ENSURE | | | THAT THE BASE BUILDING DESIGNERS ARE AWARE OF ANY | | | CHANGES WHICH MAY BE MADE THAT WILL ALTER THE BASE | | | BUILDING DESIGN OR PLANS PRIOR TO FINAL INSPECTIONS. IN | | | ADDITION, ANY NEW INFORMATION PROVIDED REGARDING ENERGY | | | UTILIZING SYSTEMS IN THIS SPACE WILL NEED TO BE | | | INCLUDED IN THE BASE BUILDING ENERGY CALCULATIONS AND | | | SUBMITTED AS A REVISION PRIOR TO C.O. OF THE BASE | | | BUILDING. | | | | | | 2. OK | | | | | | 3. **PARTIALLY ADDRESSED** PAGE M1 DUCT TAKEOFF DETAIL: | | | IN NO CASE SHALL THE MATERIAL SUPPORTING FLEXIBLE DUCT | | | THAT IS IN DIRECT CONTACT WITH IT BE LESS THAN 1.5 | | | INCHES WIDE IN ACCORDANCE WITH FBCM 603.5.6.6. | | | | | | 4. OK | | | | | | 5. OK | | | | | | 6. **NOT ADDRESSED** PAGE M1 PLUMBING NOTE #18: THIS | | | NOTE CALLS FOR PVC O BE USED FOR THE CONDENSATE DRAIN | | | LINE. PVC MAY NOT BE USED IN THE MECHANICAL ROOM WHICH | | | ALSO SERVES AS A RETURN AIR PLENUM. MATERIALS EXPOSED | | | WITHIN PLENUMS SHALL BE NONCOMBUSTIBLE OR SHALL HAVE A | | | FLAME SPREAD INDEX OF NOT MORE THAN 25 AND A | | | SMOKE-DEVELOPED INDEX OF NOT MORE THAN 50 WHEN TESTED | | | IN ACCORDANCE WITH ASTM E 84 PER FBCM 602.2.1. | | | | | | 7. OK | | | | | | 8. **NOT ADDRESSED** PAGE A.1 SHOWS A SINGLE DOOR IN | | | MECHANICAL ROOM 204. PAGE M1 FLOOR PLAN SHOWS A | | | LOUVERED DOUBLE-DOOR AT THIS LOCATION. WHICH IS | | | CORRECT? NO DOOR SCHEDULE COULD BE FOUND IN THE | | | ARCHITECTURAL PLANS TO SHOW WHICH TYPE OF DOOR IS TO BE | | | USED AT THIS LOCATION. PLEASE SHOW THE DOOR TYPES TO | | | VERIFY THAT A LOUVERED DOOR IS BEING PROVIDED FOR | | | RETURN AIR. ALSO, THE TYPE OF DOOR SHALL MEET THE | | | REQUIREMENTS FOR A PLENUM IN ACCORDANCE WITH FBCM | | | 602.2.1. | | | | | | 9. SEE ABOVE. | | | | | | 10. OK | | | | | | 11. OK | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2008-08-20 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-08-20 |
Time |
14:18 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-08-20 |
Time |
11:41 |
Sent To |
PC |
|
| Notes |
| 2008-08-20 14:18:18 | REVIEW #: 1ST | | | ACTION: DENIED | | | | | | FBC 2004 CODE FAMILY W/ 2007 SUPPLEMENTS | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | 1. THIS APPLICATION IS FOR A TENANT IMPROVEMENT IN A | | | BUILDING WHICH IS NOT YET COMPLETED. IF THIS PERMIT IS | | | TO BE ISSUED PRIOR TO C.O. OF THE BASE BUILDING, THE | | | DESIGNERS F THE BASE BUILDING SHALL PERFORM A SHOP | | | DRAWING REVIEW OF THESE PLANS AND APPROVE THEM IN | | | WRITING (SHOP DRAWING REVIEW STAMP). THIS IS TO ENSURE | | | THAT THE BASE BUILDING DESIGNERS ARE AWARE OF ANY | | | CHANGES WHICH MAY BE MADE THAT WILL ALTER THE BASE | | | BUILDING DESIGN OR PLANS PRIOR TO FINAL INSPECTIONS. IN | | | ADDITION, ANY NEW INFORMATION PROVIDED REGARDING ENERGY | | | UTILIZING SYSTEMS IN THIS SPACE WILL NEED TO BE | | | INCLUDED IN THE BASE BUILDING ENERGY CALCULATIONS AND | | | SUBMITTED AS A REVISION PRIOR TO C.O. OF THE BASE | | | BUILDING. | | | | | | 2. PROVIDE COOLING LOAD CALCULATIONS FOR THIS SPACE IN | | | ACCORDANCE WITH FBCB 13-407.1.ABC.1. | | | | | | 3. PAGE M1 DUCT TAKEOFF DETAIL: HORIZONTAL DUCT SHALL | | | BE SUPPORTED AT INTERVALS NOT GREATER THAN 5 FEET AND | | | HANGERS, SADDLES AND OTHER SUPPORTS SHALL MEET THE DUCT | | | MANUFACTURER?S RECOMMENDATIONS AND SHALL BE OF | | | SUFFICIENT WIDTH TO PREVENT RESTRICTION OF THE INTERNAL | | | DUCT DIAMETER. IN NO CASE SHALL THE MATERIAL SUPPORTING | | | FLEXIBLE DUCT THAT IS IN DIRECT CONTACT WITH IT BE LESS | | | THAN 1? INCHES WIDE IN ACCORDANCE WITH FBCM 603.5.6.6. | | | | | | 4. LOCATION OF CONDENSATE DISPOSAL NOT SHOWN ON PLANS. | | | CONDENSATE FROM ALL COOLING COILS AND EVAPORATORS SHALL | | | BE CONVEYED FROM THE DRAIN PAN OUTLET TO AN APPROVED | | | PLACE OF DISPOSAL. CONDENSATE SHALL NOT DISCHARGE INTO | | | A STREET, ALLEY OR OTHER AREAS SO AS TO CAUSE A | | | NUISANCE IN ACCORDANCE WITH FBCM 307.2.1. | | | | | | 5. PROVIDE AUXILIARY OR SECONDARY DRAIN PROTECTION IN | | | ACCORDANCE WITH FBCM 307.2.3. | | | | | | 6. PAGE M1 PLUMBING NOTE #18: THIS NOTE CALLS FOR PVC O | | | BE USED FOR THE CONDENSATE DRAIN LINE. PVC MAY NOT BE | | | USED IN THE MECHANICAL ROOM WHICH ALSO SERVES AS A | | | RETURN AIR PLENUM. MATERIALS EXPOSED WITHIN PLENUMS | | | SHALL BE NONCOMBUSTIBLE OR SHALL HAVE A FLAME SPREAD | | | INDEX OF NOT MORE THAN 25 AND A SMOKE-DEVELOPED INDEX | | | OF NOT MORE THAN 50 WHEN TESTED IN ACCORDANCE WITH ASTM | | | E 84 PER FBCM 602.2.1. | | | | | | 7. PAGE M1: NO INFORMATION WAS PROVIDED ON PLANS | | | REGARDING THE CFM OF THE TOILET ROOM EXHAUST FAN. | | | PROVIDE A FAN SCHEDULE WITH MAKE, MODEL, VOLTS, AMPS | | | AND EXHAUST RATE EXPRESSED IN CFM. EXHAUST RATE SHALL | | | BE IN COMPLIANCE WITH FBCM 403.4 AND ASHRAE 62.1-2004 | | | TABLE 6-4. | | | | | | 8. PAGE A.1 SHOWS A SINGLE DOOR IN MECHANICAL ROOM 204. | | | PAGE M1 FLOOR PLAN SHOWS A LOUVERED DOUBLE-DOOR AT THIS | | | LOCATION. WHICH IS CORRECT? NO DOOR SCHEDULE COULD BE | | | FOUND IN THE ARCHITECTURAL PLANS TO SHOW WHICH TYPE OF | | | DOOR IS TO BE USED AT THIS LOCATION. PLEASE SHOW THE | | | DOOR TYPES TO VERIFY THAT A LOUVERED DOOR IS BEING | | | PROVIDED FOR RETURN AIR. ALSO, THE TYPE OF DOOR SHALL | | | MEET THE REQUIREMENTS FOR A PLENUM IN ACCORDANCE WITH | | | FBCM 602.2.1. | | | | | | 9. PAGE M1 CALLS FOR A LOUVERED DOOR FOR RETURN AIR | | | ABOVE THE DOOR IN MECHANICAL ROOM 204. NO SUCH DOOR IS | | | SHOWN ON ARCHITECTURAL PLANS. SHOW THE LOCATION AND | | | SIZE OF THE RETURN OPENING ON THE MECHANICAL PLANS. AIR | | | DISTRIBUTION SYSTEMS SHALL BE DESIGNED AND INSTALLED TO | | | PROVIDE THE REQUIRED DISTRIBUTION OF AIR IN ACCORDANCE | | | WITH FBCM 603.1. ALSO, BALANCED RETURN IS REQUIRED IN | | | ACCORDANCE WITH FBCM 601.4. | | | | | | 10. THE OUTSIDE AIR INTAKE DUCT SHALL BE PROVIDED WITH | | | AUTOMATIC SHUTOFF DAMPER CONTROLS IN ACCORDANCE WITH | | | FBCB 13-409.1.ACB 3.3. | | | | | | 11. THE OUTSIDE AIR CALCULATIONS DO NOT CORRESPOND WITH | | | ASHRAE 62.1-2004 SECTION 6.2. EXAMPLE: THE OCCUPANCY | | | SHOULD BE BASED ON A RETAIL OCCUPANCY ON TABLE 6-1. | | | BASED ON THIS OCCUPANCY AND THE SIZE OF THE SPACE GIVEN | | | ON THE PLANS, A MINIMUM VENTILATION RATE OF 227 CFM IS | | | REQUIRED IN ACCORDANCE WITH FBCM 403.4 AND ASHRAE | | | 62.1-2004 SECTION 6.2. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2009-07-14 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-07-14 |
Time |
16:13 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-07-14 |
Time |
16:13 |
Sent To |
|
|
| Notes |
| 2009-07-14 16:14:26 | REVISION #6 REPLACED REVISION #5 NO CHANGE NOTED. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2009-05-06 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-05-06 |
Time |
09:44 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-05-05 |
Time |
16:54 |
Sent To |
|
|
| Notes |
| 2009-05-06 09:45:37 | REVISION OK -- SHT M1 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2008-12-30 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2008-12-30 |
Time |
10:55 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2008-12-30 |
Time |
10:06 |
Sent To |
|
|
| Notes |
| 2008-12-30 10:53:14 | PLUMBING REVIEW OK. CALLED STEPHEN ROY TO GET OK TO | | | CHANGE LAV. HEIGHT ON SHEET A.4 FROM 2'-11" TO 2'- 10" | | | . HE IS CHANGING HIS OFFICE SET TO MATCH. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2008-11-05 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-11-05 |
Time |
13:32 |
Rev Time |
1.00 |
| Received By |
mperson |
Date |
2008-11-05 |
Time |
13:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2008-08-08 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-08-08 |
Time |
14:46 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-08-08 |
Time |
14:46 |
Sent To |
|
|
| Notes |
| 2008-08-08 15:01:10 | PLUMBING PLAN REVIEW: | | | DENIED: | | | | | | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | | PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE. | | | | | | 1. SHEET A.1 KITCHEN ELEVATIONS DETAIL #1: PLEASE | | | PROVIDE THE FOLLOWING INFORMATION FOR THE BREAK ROOM | | | SINK ON THE ELEVATION DETAIL COMPLIANT WITH THE | | | FBC-2004 CHAPTER 11, FLORIDA ACCESSIBILITY CODE | | | SECTIONS. | | | | | | 11-4.24.3 KNEE CLEARANCE. MINIMUM 27" HIGH, 30" WIDE, | | | AND 19" DEEP. | | | | | | 11-4.24.4 DEPTH. MAXIMUM 6-1/2" DEEP. | | | | | | 11-4.24.5 CLEAR FLOOR SPACE. 30" X 48" AND CLEAR FLOOR | | | SPACE SHALL EXTEND A MAXIMUM OF 19" UNDERNEATH THE | | | SINK. CLEARLY INDICATE THIS ON SHEET A.1 FIRST FLOOR | | | TENANT BUILD-OUT PLAN DETAIL #2. | | | | | | 11-4.24.7 FAUCETS. LEVER-OPERATED, PUSH-TYPE, OR | | | ELECTRONICALLY CONTROLLED ARE ACCEPTABLE DESIGNS. | | | | | | 2. SHEET A.4 KEY NOTES #8, #9 AND SHEET M1 PLUMBING | | | FIXTURE SCHEDULE MARK 1, 2 ARE INDICATING DIFFERENT | | | MODEL FIXTURES FOR THE WATER CLOSET, LAVATORIES AND THE | | | LAVATORY FAUCETS. PLEASE KNOW THAT AN ONLINE SEARCH FOR | | | THE INDICATED AMERICAN STANDARD FIXTURE MODELS CAME UP | | | "NO RECORDS TO DISPLAY FOR THOSE FIXTURES. PLEASE | | | CORRECT, CORRELATE, AND PROVIDE MANUFACTURER SPEC | | | SHEETS FOR FIXTURES. PER FBC-2004 PLUMBING SECTION | | | 401.1 SCOPE. | | | | | | 3. SHEET M1 SANITARY ISOMETRIC: PLEASE CORRECT THE | | | FOLLOWING PER THE FBC-2004 PLUMBING SECTIONS. | | | | | | A} CLEARLY INDICATE THE SIZE OF THE LAVATORY AND | | | DRINKING FOUNTAIN WATER-SEAL TRAPS. PLEASE KNOW THAT IF | | | TRAPS ARE 1-1/4"CLEANOUTS WILL BE REQUIRED AT THE | | | BASE OF THEIR STACKS. PER SECTION 701.1 SCOPE AND | | | SECTION 708.3.4. BASE OF STACK. | | | | | | B} CLEARLY INDICATE THE SIZE OF THE WATER SEAL TRAP | | | FOR THE SINK. PER SECTION 701.1 SCOPE. | | | | | | 4. SHEET M1 HVAC & PLUMBING: CLEARLY INDICATE ON THE | | | RESUBMITTED PLANS WHERE THE CONDENSATE TIE-IN DRAIN | | | PIPING TERMINATION POINT IS. DOES IT TIE INTO AN | | | EXISTING SYSTEM? PLEASE KNOW THAT THE CONDENSATE SHALL | | | NOT DISCHARGE INTO A STREET, ALLEY OR OTHER AREAS SO AS | | | TO CAUSE A NUISANCE. PER SECTION 314.2.1 CONDENSATE | | | DISPOSAL. | | | | | | 5. THE PROPOSED BUILD-OUT OF SUITE 106 IS IN A BASE | | | BUILDING THAT DOES NOT YET HAVE A CERTIFICATE OF | | | OCCUPANCY, SO THE BASE BUILDING DESIGN PROFESSIONALS | | | WILL BE REQUIRED TO PROVIDE A SHOP DRAWING REVIEW STAMP | | | ON ANY BUILD-OUT PLANS THAT ARE PREPARED BY DIFFERENT | | | DESIGNERS. PER FS 481, 481. | | | | | | ********IMPORTANT INFORMATION******** | | | WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE | | | OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW | | | PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | PHONE= (561) 805-6730 | | | FAX= (561) 805-6731 | | | E-MAIL= [email protected] | | | | | | | | | . |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2008-08-05 |
|
|
Cont ID |
|
| Sent By |
mflis |
Date |
2008-08-05 |
Time |
15:32 |
Rev Time |
0.00 |
| Received By |
mflis |
Date |
2008-08-05 |
Time |
15:32 |
Sent To |
|
|
| Notes |
| 2008-08-05 15:33:09 | ZONING REVIEW: NOT REQUIRED | | | | | | ** INTERIOR BUILD-OUT ONLY | | | ** SIGNAGE TO BE SUBMITTED UNDER SEPARATE PERMIT ** | | | SALES OFFICE FOR DEVELOPMENT | | | | | | MATT FLIS - 822-1445 |
|
|