| Plan Review Stops For Permit 08070646 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2008-07-31 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2008-07-31 |
Time |
18:16 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2008-07-31 |
Time |
18:16 |
Sent To |
|
|
| Notes |
| 2008-07-31 18:16:54 | PLANS REVIEWED AND STAMPED BY LUIS MARTINEZ ON 7/30/08. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2008-09-04 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-09-04 |
Time |
16:32 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-09-04 |
Time |
16:31 |
Sent To |
|
|
| Notes |
| 2008-09-04 16:32:00 | | | | | | | | | | | | | PROVISO | | | | | | 907.2.10.1.2 GROUPS R-2, R-3, R-4 AND I-1. | | | SINGLE- OR MULTIPLE-STATION SMOKE ALARMS SHALL BE | | | INSTALLED AND MAINTAINED IN GROUPS R-2, R-3, R-4 AND | | | I-1, REGARDLESS OF OCCUPANT LOAD AT ALL OF THE | | | FOLLOWING LOCATIONS: | | | 1. ON THE CEILING OR WALL OUTSIDE OF EACH SEPARATE | | | SLEEPING AREA IN THE IMMEDIATE VICINITY OF BEDROOMS. | | | 2. IN EACH ROOM USED FOR SLEEPING PURPOSES. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2008-08-25 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-08-25 |
Time |
16:30 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-08-25 |
Time |
15:55 |
Sent To |
|
|
| Notes |
| 2008-08-25 16:30:04 | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2005 | | | NEC, NFPA-72 2002, NFPA-101 2003, 2004 FBC AS AMENDED, | | | CHAPTER 1.AND FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | | | | 1} THE PERSON TAKING RESPONSIBILITY FOR THE DESIGN MUST | | | PRINT AND SIGN THEIR NAME TO SAME PER 106.3.4.3. FBC. | | | IF AN ARCHITECT OR ENGINEER, COMPLY WITH 481 AND 471 | | | FS, RESPECTIVELY. | | | THE CONTRACTOR OF RECORD MAY BE THE DESIGN PROFESSIONAL | | | IF EXEMPTIONS UNDER CHAPTER 471.003, FLORIDA STATUTES, | | | IF EXEMPTIONS APPLY. SEE FS 481.229(C) INDICATING WORK | | | OVER $25000.00 REQUIRES AN ARCHITECT AND EXEMTIONS DO | | | NOT APPLY | | | | | | 2} PLEASE NOTE THAT HAND DRAWN CHANGES TO THE PLAN ARE | | | NOT ACCEPTABLE AS THEY CANNOT BE VERIFIED AS BEING MADE | | | BY THE DESIGNER OF RECORD AS REQUIRED BY FS 471 OR 481, | | | AS APPLICABLE. | | | | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
N |
Date |
2008-08-01 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-08-01 |
Time |
11:38 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-08-01 |
Time |
11:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2008-08-29 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-08-29 |
Time |
09:16 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-08-29 |
Time |
09:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2008-08-05 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-08-05 |
Time |
14:20 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-08-05 |
Time |
13:40 |
Sent To |
|
|
| Notes |
| 2008-08-05 14:19:55 | *****DENIED***** | | | | | | | | | 1.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241. | | | | | | 2.COMBUSTIBLE WASTE MATERIALS, DUST, AND DEBRIS SHALL | | | BE REMOVED FROM THE SITE AT THE END OF EACH SHIFT OR | | | MORE FREQUENTLY AS NECESSARY FOR SAFE OPERATION. | | | | | | 3THE REMOVAL OF AND/OR STOCKING OF BUILDING MATERIALS | | | AND SUPPLIES SHALL NOT BE STORED IN THE EXIT AISLE | | | CORRIDORS AS TO HINDER OR INTERFERE WITH ACCESS TO / | | | EGRESS FROM OTHER TENANT SPACES ON THE FLOOR OR THE | | | BUILDING.. | | | | | | 4.NFPA 101, LIFE SAFETY CODE, 2003 EDITION SHALL BE | | | REFERENCED. | | | | | | 5.SPECIFY THE THE INTERIOR FINISH MATERIAL FOR ANY | | | NEW WALLS AND CEILINGS IN TERMS OF CLASS A, CLASS B, OR | | | CLASS C. | | | | | | 6.SHOW THE LOCATION OF THE SMOKE ALARMS (SA) FOR THE | | | PROPOSED FLOOR PLAN. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING WHERE IN THE PLAN EACH COMMENT WAS | | | ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-09-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-09-03 |
Time |
12:33 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-09-03 |
Time |
12:33 |
Sent To |
|
|
| Notes |
| 2008-09-03 12:36:29 | TO "BOB"#2 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-08-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-08-18 |
Time |
16:15 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-08-18 |
Time |
16:15 |
Sent To |
|
|
| Notes |
| 2008-08-25 08:28:01 | TO BOB #2. | | 2008-08-18 16:16:13 | WAITING FOR "BOB" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-08-05 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-08-05 |
Time |
13:40 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-07-23 |
Time |
11:05 |
Sent To |
|
|
| Notes |
| 2008-07-28 09:05:24 | TO "BOB"#13 | | 2008-07-23 11:12:28 | WAITING FOR "BOB" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2008-08-26 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-08-26 |
Time |
14:45 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2008-08-26 |
Time |
14:45 |
Sent To |
|
|
| Notes |
| 2008-08-26 14:46:46 | *** PROVISO *** | | | 1)IN REGARDS TO THE A/C UNIT. PER 2004 FBC/R M1305.1 | | | APPLIANCE ACCESS FOR INSPECTION SERVICE, REPAIR AND | | | REPLACEMENT. | | | APPLIANCES SHALL BE ACCESSIBLE FOR INSPECTION, SERVICE, | | | REPAIR AND REPLACEMENT WITHOUT REMOVING PERMANENT | | | CONSTRUCTION. THIRTY INCHES OF WORKING SPACE SHALL BE | | | PROVIDED IN FRONT OF THE CONTROL SIDE TO SERVICE AN | | | APPLIANCE. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2008-07-28 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-07-28 |
Time |
12:14 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2008-07-28 |
Time |
12:14 |
Sent To |
|
|
| Notes |
| 2008-07-28 12:22:28 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | *** DENIED *** | | | 1) INFORMATION MISSING FROM TITLE BLOCK. | | | SEE FAC 61G15-23.002 (2)A TITLE BLOCK ON EACH SHEET | | | CONTAINING THE PRINTED NAME, ADDRESS, AND LICENSE | | | NUMBER OF THE ENGINEER OR IF APPLICABLE, THE NAME AND | | | LICENSE NUMBER OF THE ENGINEER, AND THE NAME, ADDRESS | | | AND CERTIFICATE OF AUTHORIZATION NUMBER OF THE | | | ENGINEERING BUSINESS WILL SATISFY THIS REQUIREMENT. | | | | | | 2) NOTICE: IN REGARDS TO THE A/C UNIT. PER 2004 FBC/R | | | M1305.1 APPLIANCE ACCESS FOR INSPECTION SERVICE, REPAIR | | | AND REPLACEMENT. | | | APPLIANCES SHALL BE ACCESSIBLE FOR INSPECTION, SERVICE, | | | REPAIR AND REPLACEMENT WITHOUT REMOVING PERMANENT | | | CONSTRUCTION. THIRTY INCHES OF WORKING SPACE SHALL BE | | | PROVIDED IN FRONT OF THE CONTROL SIDE TO SERVICE AN | | | APPLIANCE. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2008-09-05 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-09-05 |
Time |
08:19 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-09-05 |
Time |
08:19 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2008-08-26 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-08-26 |
Time |
10:27 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-08-26 |
Time |
10:07 |
Sent To |
|
|
| Notes |
| 2008-08-26 10:26:36 | PLUMBING PLAN REVIEW: | | | DENIED 2ND TIME: | | | | | | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | | | THE FOLLOWING COMMENTS ARE NUMBERED TO CORRESPOND WITH | | | THE PREVIOUS PLUMBING REVIEW COMMENTS AS WELL AS THE | | | DESIGNER'S RESPONSES FOR THE PURPOSE OF CONTINUITY. NEW | | | COMMENTS WILL BE SO NOTED FOLLOWING THE PREVIOUS REVIEW | | | COMMENTS. | | | | | | 1. "OK" COMMENT ADDRESSED. | | | | | | 2. "OK" COMMENT ADDRESSED. | | | | | | **THE FOLLOWING IS A NEW COMMENT** | | | | | | 3. THE SANITARY ISOMETRIC RISER DIAGRAMS REQUIRE THE | | | FOLLOWING. | | | NOTE: ALL PLANS, SPECIFICATIONS, AND ACCOMPANYING DATA | | | BEING FILED FOR PUBLIC RECORD SHALL CONTAIN THE PRINTED | | | NAME OF THE RESPONSIBLE PERSON WITH THE ORIGINAL | | | SIGNATURE AND DATE ON SUCH INFORMATION. PER (W.P.B. AS | | | AMENDED) SECTION *106.3.4.3. PLEASE KNOW THAT THE | | | PLUMBING CONTRACTOR UNDER PROVISION OF FS 471.003(2)(H) | | | AND FBCB 105.3.1.2 CAN BE THE DESIGNER AS LONG AS THEY | | | ARE THE INSTALLER OF THE SYSTEM THEY DESIGN. | | | IF THE DESIGN PROFESSIONAL IS AN ARCHITECT OR | | | ENGINEER, THEN HE OR SHE SHALL AFFIX HIS OR HER | | | OFFICIAL SEAL, SIGNATURE AND DATE TO SAID DRAWINGS, PER | | | FLORIDA STATUTES 481 AND 471 RESPECTIVELY. | | | | | | ********IMPORTANT INFORMATION******** | | | WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE | | | OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW | | | PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | PHONE= (561) 805-6730 | | | FAX= (561) 805-6731 | | | E-MAIL= [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2008-07-31 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-07-31 |
Time |
10:58 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-07-31 |
Time |
10:58 |
Sent To |
|
|
| Notes |
| 2008-07-31 11:09:40 | PLUMBING PLAN REVIEW: | | | DENIED: | | | | | | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | | PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE. | | | | | | 1. INFORMATION MISSING FROM TITLE BLOCK. | | | SEE FAC 61G15-23.002 (2)A TITLE BLOCK ON EACH SHEET | | | CONTAINING THE PRINTED NAME, ADDRESS, AND LICENSE | | | NUMBER OF THE ENGINEER OR IF APPLICABLE, THE NAME AND | | | LICENSE NUMBER OF THE ENGINEER, AND THE NAME, ADDRESS | | | AND CERTIFICATE OF AUTHORIZATION NUMBER OF THE | | | ENGINEERING BUSINESS WILL SATISFY THIS REQUIREMENT. | | | | | | 2. PROPOSED FLOOR PLAN BATH 1: PLEASE CLARIFY IF THE | | | TUB IS BEING REPLACED WITH A SHOWER IN THIS BATH. THE | | | FIXTURE BEING INDICATED ON THE PLANS IS A SHOWER. PER | | | FBC-2004 PLUMBING SECTION 401.1 SCOPE. | | | | | | ********IMPORTANT INFORMATION******** | | | WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE | | | OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW | | | PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | PHONE= (561) 805-6730 | | | FAX= (561) 805-6731 | | | E-MAIL= [email protected] |
|
|