Plan Review Details - Permit 08070618
Plan Review Stops For Permit 08070618
Review Stop AD ADDRESSING
Rev No 2 Status P Date 2009-03-10 Cont ID  
Sent By jnguyen Date 2009-03-10 Time 09:24 Rev Time 0.00
Received By jnguyen Date 2009-03-09 Time 16:27 Sent To  
Notes
2009-03-10 09:12:53NOW REALIZING THAT THE BUILDING & ZONING DEPARTMENTS
 DEFINED TOWNHOMES DIFFERENTLY, AND CONSIDERING THE FACT
 THAT THESE UNITS WERE NOT FEE SIMPLE. I CORRECTED THE
 ADDRESSES ON THIS PARCEL TO RETAIN THE NEWLY ADJUSTED
 PRIMARY ADDRESS OF 1301 HENRIETTA AVE (EAST STRUCTURE)
 & THE SECONDARY ADDRESS OF 1307 HENRIETTA AVE (WEST
 STRUCTURE). I SENT OUT A NOTIFICATION E-MAIL TO ALL OF
 THE RELEVANT PARTIES INFORMING THEM THAT 1303, 1305 &
 1311-1325 HENRIETTA AVE WERE NO LONGER VALID (THEIR
 CORRESPONDING RECORDS WERE DELETED IN THE GIS &
 COMMUNITYPLUS DATABASES). I ALSO E-MAILED PAPA TO
 CHANGE THEIR PRIMARY ADDRESS ON THEIR WEB SITE. I HAVE
 CORRECTED THE ADDRESS FROM 1325 TO 1301 HENRIETTA AVE
 ON THE ORIGINAL PERMIT APPLICATION. THE DEVELOPER WILL
 EVENTUALLY BE RESPONSIBLE FOR ASSIGNING INDIVIDUAL
 DESIGNATORS TO ALL UNITS INSIDE THE STRUCTURE(S), ONCE
 THE CERTIFICATE OF OCCUPANCY HAS BEEN ISSUED (I.E.,
 #100-199 OFF THE MAIN ADDRESS OF THE BUILDING - 1301
 HENRIETTA AVE # 105).

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2009-03-09 Cont ID  
Sent By jnguyen Date 2008-12-12 Time 17:24 Rev Time 0.00
Received By jnguyen Date 2008-12-12 Time 08:00 Sent To  
Notes
2008-12-12 17:24:16I HAVE REVIEWED THE SITE & FLOOR PLANS FOR THIS PERMIT
 ON PCN# 74434316020300080. THE FORMER PRIMARY SITE
 ADDRESS FOR THIS PARCEL WAS 605 PALM BEACH LAKES BLVD
 (WHICH IS NOW INVALID & NO LONGER IN USE). AFTER
 THOROUGHLY ANALYZING THE SITE & PLANS, I NOTICED THAT
 THE MAIN ENTRANCE TAKES ACCESS FROM A ONE-WAY ALLEY
 THAT RUNS EAST TO WEST STARTING FROM HENRIETTA AVE TO N
 SAPODILLA AVE. I TALKED TO THE CONTRACTOR DWAYNE
 RANDOLPH & CONFIRMED THAT THE PROPOSED PARKING LOT &
 THE FRONT OF BUILDING B EXCLUSIVELY FACES THIS ONE-WAY
 ALLEY (NOT PALM BEACH LAKES BLVD). IN ACCORDANCE WITH
 OUR ADDRESSING POLICIES, I HAVE CHANGED THE PRIMARY
 SITE ADDRESS FOR PCN# 74434316020300080 TO 1325
 HENRIETTA AVE IN THE GIS & COMMUNITYPLUS DATABASES. I
 ALSO INFORMED ALL OF THE RELEVANT PARTIES (PALM BEACH
 COUNTY, USPS, FPL, ETC.) OF THE CHANGE FOR THIS PRIMARY
 SITE ADDRESS IN A NOTIFICATION E-MAIL. FOR BUILDING B
 ON THE SITE PLAN, WHICH IS TO THE SOUTH OF THE PROPOSED
 PARKING LOT & CONSISTS OF SIX TWO-STORY UNITS, I HAVE
 ASSIGNED THEM THE FOLLOWING UNIQUE SECONDARY ADDRESSES
 (FROM WEST TO EAST): 1301 HENRIETTA AVE, 1303 HENRIETTA
 AVE, 1305 HENRIETTA AVE, 1307 HENRIETTA AVE, 1309
 HENRIETTA AVE & 1311 HENRIETTA AVE (SHOWN IN
 COMMUNITYPLUS UNDER PCN# 74434316020300080 AS UNIT
 RECORDS 0001 TO 0006). FOR THE "OPEN YARD" ON THE SITE
 PLAN, WHICH IS BETWEEN BUILDINGS B & A, I HAVE ASSIGNED
 IT THE SECONDARY ADDRESS OF 1313 HENRIETTA AVE, SO JUST
 IN CASE ANOTHER STRUCTURE OR PLAYGROUND EVENTUALLY GETS
 BUILT DOWN THE LINE IN THIS VACANT LOT (SHOWN IN
 COMMUNITYPLUS UNDER PCN# 74434316020300080 AS UNIT
 RECORD 0007). FOR BUILDING A ON THE SITE PLAN, WHICH IS
 TO THE EAST OF THE PROPOSED PARKING LOT & CONSISTS OF
 FIVE TWO-STORY UNITS, I HAVE ASSIGNED THEM THE
 FOLLOWING UNIQUE SECONDARY ADDRESSES (FROM BOTTOM TO
 TOP): 1315 HENRIETTA AVE, 1317 HENRIETTA AVE, 1319
 HENRIETTA AVE, 1321 HENRIETTA AVE & 323 HENRIETTA AVE
 (SHOWN IN COMMUNITYPLUS UNDER PCN# 74434316020300080 AS
 UNIT RECORDS 0008TO 0012). I HAVE ALSO NOTIFIED THE
 APPROPRIATE PERSONNEL OF ALL OF THESE NEWLY ISSUED
 SECONDARY ADDRESSES FROM 1301 TO 1323 HENRIETTA AVE.
 PLEASE CHANGE THE ADDRESS ON THE ORIGINAL PERMIT
 APPLICATION FROM 605 PALM BEACH LAKES BLVD (NO LONGER
 GOOD) TO 1325 HENRIETTA AVE SINCE I ONLY HAVE A COPY.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2009-11-03 Cont ID  
Sent By rmcdouga Date 2009-11-03 Time 13:55 Rev Time 0.00
Received By rmcdouga Date 2009-11-03 Time 13:55 Sent To  
Notes
2009-11-03 14:07:29REVIEWED TRUSS DRAWINGS FOR CODE COMPLIANCE.
  
 CORRECTIONS TO THE TRUSS ANCHOR SCHEDULE ON SHEET S-10
 ARE REQUIRED. ANCHOR MARK 05 SHOULD BE USC 63 BECAUSE
 THE ROOF PITCH IS 6:12. ANCHOR MARK 6.1 SHOULD ALSO BE
 USC 63 WITH AN UPLIFT CAPACITY OF 11,150 #. A SIGNED
 AND SEALED LETTER OF CLARIFICATION FROM THE DESIGNER OF
 RECORD AS DISCUSSED WITH THE ARCHITECT WILL BE
 ACCEPTABLE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status N Date 2009-10-20 Cont ID  
Sent By rmcdouga Date 2009-10-20 Time 09:14 Rev Time 0.00
Received By rmcdouga Date 2009-10-20 Time 09:14 Sent To  
Notes
2009-10-20 09:23:00TRUSS DRAWINGS ARE DENIED
 CORRECTIONS ARE REQUIRED.
  
 1) THE FLOOR TRUSS AND LOWER ROOF LAYOUT SPECIFIES THE
 DESIGN CRITERIA AS FBC 07 / ASCE 7-05 AND EXPOSURE B.
 THE TRUSS DRAWING COVERSHEET SPECIFIES EXPOSURE C. THE
 LOWER ROOF TRUSS DRAWINGS IN THIS PACKAGE SPECIFY ASCE
 7-02 AND EXPOSURE B WITH TCDL OF 5 PSF AND BCDL OF 5
 PSF. PLEASE COORDINATE THE DESIGN CRITERIA AND LOADS
 WITH THE APPROVED PLANS. THE PLANS WERE PERMITTED UNDER
 THE 2004 FBC / ASCE 7-02 AND EXPOSURE B.
  
 NOTE YOU CAN DESIGN THE TRUSSES USING FBC 2007 AND ASCE
 7-05, HOWEVER, BECAUSE OF THE CHANGES TO THE EXPOSURE
 CATEGORY DETERMINATIONS IN THE 2009 REVISIONS TO FBC
 07, THE STRUCTURE IS IN EXPOSURE CATEGORY C USING THIS
 DESIGN CRITERIA.
  
 2) ON THE UPPER ROOF TRUSS DRAWINGS THE UPLIFT FOR ROOF
 GIRDER TRUSS C2 OF 1915# EXCEEDS THE CAPACITY OF THE
 ANCHOR SPECIFIED ON THE PLANS OF 1115#. SEE ANCHOR 6.1
 ON SHEET S-10. ALSO IF USING FBC 2007 AND ASCE 7-05,
 THE EXPOSURE CATEGORY IS C, NOT B. PLEASE CORRECT.
  
 3) THE TRUSS LAYOUT DRAWINGS ARE REQUIRED TO BE SIGNED
 AND SEALED BY THE TRUSS ENGINEER. THE SIGNATURE ON THE
 TRUSS DRAWING COVER SHEET IS REQUIRED TO BE AN ORIGINAL
 WET SIGNATURE, PHOTO-COPIES, STAMPS, ETC. ARE NOT
 ALLOWED. FAC 61G-15-23.002 AND FS 471. ELECTRONIC
 SIGNATURES OR DIGITAL SIGNATURES ARE ONLY USED FOR
 PLANS OR OTHER DOCUMENTS ARE TRANSMITTED
 ELECTRONICALLY. SEE SS 668.002 AND FAC 61G15-23.003.
  
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2009-03-17 Cont ID  
Sent By mjacobs Date 2009-03-17 Time 13:53 Rev Time 0.00
Received By mjacobs Date 2009-03-17 Time 13:53 Sent To  
Notes
2009-03-17 14:59:48NEED TO INDICATE CORRECT ADDRESS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-08-20 Cont ID  
Sent By mjacobs Date 2008-08-20 Time 11:35 Rev Time 0.00
Received By mjacobs Date 2008-08-18 Time 07:43 Sent To  
Notes
2008-08-20 07:52:112ND REVIEW 8-18-08
  
 BUILDING PLAN REVIEW
 PERMIT: 08070618
 ADD: 605-609 PBL BLVD.
 CONT: D. STEPHENSON CONSTRUCTION
 TEL: (954)315-7020
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2006 / 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW: 2ND
 ACTION: DENIED
  
 ALL PLANS SUBMITTED AFTER OCTOBER, 1, 2004 SHALL BE
 DESIGNED TO THE 2004 FLORIDA BUILDING CODE WITH THE
 2007 REVISIONS. THE PERMIT APPLICATION STILL DESCRIBES
 THE PROJECT AS TOWNHOUSES. THESE ARE NOT TOWNHOUSES AND
 WILL BE REVIEWED AS R-2 MULTI-FAMILY DWELLINGS.
 1) OK
 2) OK
 3) OK
 4) OK
 5) OK
  
 NOTED: SUBMIT THE BLUE RECEIT FOR THE IMPACT FEES FROM
 PALM BEACH COUNTY.
 6) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
 *******************************************************
 *******************************************************
 ******************
  
 7) NOTED: HOWEVER, THE REPORT MAKES REFERENCE TO FBC
 2001. ALL PLANS SUBMITTED AFTER OCTOBER, 1, 2004 SHALL
 BE DESIGNED TO THE 2004 FLORIDA BUILDING CODE. THE SOIL
 INVESTIGATION REPORT SHALL CONTAIN THE ORIGINAL RAISED
 SEAL OF THE ENGINEER RESPONSIBLE FOR THE REPORT. FAC
 61G15-23.002. A PROFESSIONAL ENGINEER SHALL SIGN HIS
 NAME AND AFFIX HIS SEAL TO ALL PLANS, SPECIFICATIONS,
 REPORTS, FINAL BID DOCUMENTS PROVIDED TO THE OWNER OR
 THE OWNERS REPRESENTATIVE, OR OTHER DOCUMENTS PREPARED
 OR ISSUED BY SAID REGISTRANT AND BEING FILED FOR PUBLIC
 RECORD. THE DATE THAT THE SIGNATURE AND SEAL IS AFFIXED
 AS PROVIDED HEREIN SHALL BE ENTERED ON SAID PLANS,
 SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS IMMEDIATELY
 UNDER THE SIGNATURE OF THE PROFESSIONAL ENGINEER.
  
 A) FBC 1802.2.1 QUESTIONABLE SOIL. WHERE THE BEARING
 CAPACITY OF THE SOIL IS NOT DEFINITELY KNOWN OR IS IN
 QUESTION, THE BUILDING OFFICIAL SHALL REQUIRE THAT THE
 NECESSARY INVESTIGATION BE MADE. THE INVESTIGATION
 SHALL COMPLY WITH THE PROVISIONS OF SECTIONS 1802.4
 THROUGH 1802.6 OF THE FBC. THE INVESTIGATION SHALL BE
 CERTIFIED BY A GEOTECHNICAL REPORT FROM A DESIGN
 PROFESSIONAL PROPERLY LICENSED IN THE STATE OF
 FLORIDA.
  
 8) FL S S 713.13 NOTICE OF COMMENCEMENT, TO BE FILED
 WITH THE CLERK OF THE COURT. NOTE: 713.13(2). IF THE
 WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS NOT
 ACTUALLY COMMENCED WITHIN 90 DAYS AFTER THE RECORDING
 THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6).
 THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE
 CONSTRUCTION SITE BEFORE THE FIRST INSPECTION.
  
 9) OK
 10) OK
 11) OK
  
 12) FBC 2303.4.1 TRUSS CONSTRUCTION DOCUMENTS SHALL
 CONFORM TO THIS SECTION OF THE FBC AND SHALL BE
 PREPARED BY A REGISTERED DESIGN PROFESSIONAL AND
 SUBMITTED TO THE BUILDING OFFICIAL PRIOR TO
 INSTALLATION.
  
 13) OK
  
 14) NOTED: HOWEVER, SOME OF THE INFORMATION INDICATED
 ON THE FORMS FOR THE BUILDING ENVELOPE DOES NOT
 CORRESPOND WITH THE ARCHITECTURAL DRAWINGS. EXAMPLE,
 SLAB-ON-GRADE SHOWS R-13 INSULATION, ALL EXTERIOR WALLS
 ARE SHOWN AS CONCRETE, BUT WALL TYPES ?F? AND ?I?
 INDICATE 2?X6? STUD PARTITION. THE LEGEND NEEDS TO
 INDICATE THE TYPE OF STUDS ALONG WITH THE STUD SPACING
 AND THE THICKNESS OF THE EXTERIOR WALL SHEATHING. THE
 INSULATION FOR THE EXTERIOR WALLS IS SHOWN AS R-11
 HOWEVER, THE LEGEND SHOWS IT AS ?? RIGID INSULATION.
 THE ENERGY CALCULATION FORMS NEED TO CORRESPOND WITH
 THE ARCHITECTURAL DRAWINGS. THERE IS NO CONCRETE ROOF
 DECK SHOWN ON THE PLANS.
 A) FL ENERGY EFFICIENCY CODE 400.ABCD. THE PERSON
 PREPARING THE COMPLIANCE CALCULATION SHALL CERTIFY THAT
 THE CALCULATION IS TRUE AND ACCURATE & DEMONSTRATES
 THAT THE BUILDING IS IN COMPLIANCE. SEE SUBCHAPTER 13-6
 OF THE FBC.
  
 15) OK
 16) OK
 17) OK
  
 **NO RESPONSE NOT ADDRESSED**
 NOTE: THE ABBREVIATION LEGEND ON SHEET SP - 1 IS NOT
 LEGIBLE.
  
 A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A
 RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 (561)805-6726
 [email protected]

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2009-04-30 Cont ID  
Sent By dpalmer Date 2009-04-30 Time 09:17 Rev Time 0.00
Received By dpalmer Date 2009-04-29 Time 17:15 Sent To PC
Notes
2009-04-30 09:29:10PROCESSED PLANS.
 STAMPED ALL SHEETS AND DOCUMENTS WHICH WERE COMPLETED
 BY OTHER TRADES.
  
 THE NEW PERMIT NUMBER 09040579 WAS GENERATED BASED ON
 PERMIT APPLICATION REQUIRED BY THE BUILDIGN OFFICIAL
 FOR THE SECOND BUILDING. THIS IS1307 HENRIETTA AVE.
 EVEN AS THE PERMIT NUMBER IS AFTER MARCH 1ST, 2009 THE
 PLANS ARE UNDER 2004 FBC. APPLICATION WOULD HAVE BEEN
 MADE UNDER THE PREVIOUS CODE IF THE CONTRACTOR HAD
 KNOWN HE NEEDED A SEPARATE PERMIT.
  
 THE SITE DATA REPORTS FOR RAIN WATER CALCULAITONS WERE
 SIGNED BY ENGINEER HOWEVER NOT SEALED. FS 471.025, FAC
 61G15-23.002.
 THIS WAS NOTED TO MANUAL GONZALES FROM ENGINEERING.
 BOTH REPORTS ARE BEING SENT BACK OUT. THEY NEED TO BE
 SEALED CORRECTLY AND SUBMITTED AS A SUBMITTAL FOR
 ENGINEERING REVIEW AND STAMPS.
  
 CIVIL SHEETS NOT STAMPED AS REVIEWED BY ENGINEERING
 DEPT. EMAIL WAS FORWARDED TO ENGINEERING STAFF. MAIN
 SET ON FILE AT THEIR OFFICE. THE REVIEWS ARE PASSED IN
 THE COMPUTER.
  
 THE ENERGY CALCULATIONS FOR UNITS A, B, AND C WERE NOT
 STAMPED BY ANY OTHER TRADES WHICH REVIEWED ALTHOUGH
 REVIEWS FOR BUILDING, MECHANICAL AND PLUMBING ARE
 PASSED IN COMPUTER.
 THE DATE STAMP AND PERMIT NUMBER STAMP WAS ADDED TO
 REPORTS. NO REVIEW OF REPROTSFOR OTHER TRADEAS WAS DONE
 BY THIS REVIEWER.
 THE ADDRESSED WAS CHANGED BY THIS REVIEWER TO LIST BOTH
 NEW ADDRESSES AS 1301 AND 1307 HENRIETTA AVE ON THE
 ENERGY CALCULATIONS. COPIES WERE MADE FOR QUARTERLY
 REPORTING TO THE DCA.
  
  

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2009-03-09 Cont ID  
Sent By dpalmer Date 2009-03-09 Time 09:53 Rev Time 0.00
Received By dpalmer Date 2009-03-06 Time 16:28 Sent To  
Notes
2009-03-09 09:54:15 
  
  
  
  
  
  
 ** PROVISO ITEMS **
  
 THE FOLLOWING CORRECTIONS WILL BE NEEDED ALONG WITH ANY
 OTHER REVISIONS BEFORE ROUGH ELECTRICAL INSPECTIONS.
  
 1) NOTE: LOAD CALCULATIONS NEED TO BE REVISED. THE ONE
 OR MORE SMALL APPLIANCE CIRCUITS SHALL BE 1500VA FOR
 EACH. AS THERE ARE THREE PER 210.52B1, 210.11C1 EACH
 SHALL BE THE 1500VA PER 220.52.
 ONLY TWO ARE SHOWN FOR A TOTAL OF 3000VA. THE DEDICATED
 DINING ROOM CIRCUIT IS NOT FIGURED INTO CALCULATIONS.
 THIS WOULD BE A TOTAL OF 4500VA.
  
 2) NOTE: THE PANEL SCHEDULE FOR THE HOUSE LOADS STILL
 SHOW THE DEDICATED CIRCUITS FOR THE OUTSIDE LIGHTING OF
 EACH BUILDING. HOWEVER THE LIGHTING ON THE OUTSIDE OF
 EACH UNIT IS NOT FED FROM THE HOUSE PANEL. EACH FIXTURE
 IS ON EACH OF THE UNITS.
 PLEASE REVISE THE PANELS AND LOADS. 408.4, 220
  
 IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT
 TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO
 CONTACT THIS REVIEWER.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  
  
2009-03-06 16:36:35ELECTRICAL REVIEW WILL BE A PROVISO HOWEVER ON HOLD FOR
 ADDRESSING CORRECTIONS TO BE MADE.
  
 ** TEMPORARY FAILED STATUS FOR THE ADDRESSING TO BE
 REVIEWED.
 BOTH BUILDINGS ARE APPLIED UNDER ONE PERMIT AND ONE
 ADDRESS ALTHOUGH EACH BUILDING IS COMPLETELY SEPARATE.
 THE ADDRESSING REVIEWER HAS ADDED ADDRESSES FOR EACH
 UNIT AS A SEPARATE OWN LOCATION. THIS NEEDS TO BE GONE
 OVER BEFORE ISSUANCE.
 EACH BUILDING SHALL CONTAIN ITS OWN ADDRESS. HOWEVER
 THERE IS ONLY ONE PERMIT APPLICATION AT THIS TIME FOR
 BOTH BUILDINGS. THE CONTRACTOR NEEDS TO BE AWARE THAT
 BOTH BUILDINGS MUST BE COMPLETE BEFORE C OF O CAN BE
 GRANTED FOR EITHER OF THE BUILDINGS.
 ALSO THESE ARE NOT FEE SIMPLE UNITS. THE ADDRESSING IS
 BASED ON THE BUILDING WITH EACH UNIT BEING A
 SUITE/UNIT/OR APARTMENT NUMBER. EACH BUILDING HAS ONLY
 ONE ELECTRICAL SERVICE AS THIS IS A MULTI-FAMILY
 BUILDING.
 THE REVIEW WILL REMAIN IN A FAILED STATUS UNTIL
 APPLICATION/ADDRESSING IS CLEARED UP. THE INFORMATION
 WAS ROUTED TO THE ADDRESSING REVIEWER AND WILL BE GONE
 OVER.
  
 REVIEW WILL GO INTO A PASSED STATUS WITH PROVISO AFTER
 ADDRESSING IS CORRECTED.
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2008-08-08 Cont ID  
Sent By dpalmer Date 2008-08-08 Time 16:53 Rev Time 0.00
Received By dpalmer Date 2008-08-08 Time 16:53 Sent To  
Notes
2008-08-08 16:54:24 
 **DENIEDREVIEW**
  
 ** PLEASE SEE SOME ITEMS FROM PREVIOUSLY SUBMITTED
 *PLAN REVIEW * WHICH IS EXPIRED ARE STILL IN NEED OF
 ADDRESSING. PREVIOUS # WAS 07080639
 THERE ARE ALSO SOME NEW COMMENTS FROM CHANGES ON PLANS
 AND INFORMATION NOW SHOWN.
 THERE IS ALSO A NEW COMMENT
  
 1) NOTE: PLEASE ADJUST CODES ON PLANS FOR THE FBC AS
 PERMIT APPLICATION IS NOW MADE OVER ONE YEAR AFTER
 PREVIOUS *PLAN REVIEW ONLY* SOME CODES HAVE CHANGED.
 PLEASE LIST THE 2004 FBC W/2007 REVISIONS.
  
 2) PLEASE SEE THE PREVIOUS REVIEW WHICH REQUESTED ALL
 CIRCUITING TO BE SHOWN ON PLANS AND COORDINATED WITH
 THE PANEL SCHEDULES SUBMITTED. THE RESPONSE MENTIONS
 CIRCUITS ON PANEL SCHEDULES ARE SHOWN. THE CIRCUITS
 REQUIRED ON PLANS ARE STILL MISSING.
 THE CIRCUITS ON PANEL SCHEDULES ARE NOT COMPLETE FOR
 BEING SPECIFIC. PLEASE SEE THE 2005 AS THE CODE WAS
 REVISED TO STATE ALL CIRCUITS SHALL BE SPECIFIC TO
 ROOMS AND AREAS IN WHICH THEY FEED. AN EXAMPLE OF THIS
 IS THE PANEL SCHEDULE WHICH INDICATE CIRCUITS 13-20 AS
 *GENERAL LIGHTING* THE CODE WHICH WILL BE QUOTED BELOW
 STATES THIS IS NOT ACCEPTABLE.
  
 ***
 SECTION 408.4 WAS REVISED FOR THE 2005 CODE TO REQUIRE
 THAT THE IDENTIFICATION FOR EVERY CIRCUIT SUPPLIED BY A
 PANEL-BOARD OR SWITCHBOARD BE LEGIBLE AND CLEARLY STATE
 THE SPECIFIC PURPOSE FOR WHICH THE CIRCUIT IS USED.
 CIRCUITS USED FOR THE SAME PURPOSE MUST BE IDENTIFIED
 AS TO THEIR LOCATION. FOR EXAMPLE, SMALL APPLIANCE
 BRANCH CIRCUITS CAN SUPPLY OUTLETS IN THE KITCHEN,
 DINING ROOM, AND KITCHEN COUNTERTOPS. IDENTIFYING THE
 CIRCUITS AS SMALL APPLIANCE BRANCH CIRCUITS IS NOT
 ACCEPTABLE; INSTEAD, THEY SHOULD BE IDENTIFIED AS
 ``KITCHEN WALL RECEPTACLES,'' ``DINING ROOM FLOOR
 RECEPTACLE,'' OR ``KITCHEN COUNTERTOP RECEPTACLES LEFT
 OF SINK.'' CIRCUIT DIRECTORIES CONTAINING MULTIPLE
 ENTRIES WITH ONLY ``LIGHTS'' OR ``OUTLETS'' DO NOT
 PROVIDE THE SUFFICIENT DETAIL REQUIRED BY THIS
 SECTION.
  
 **
 PLEASE REVISE PANEL SCHEDULES. THERE ARE SEVERAL ITEMS
 FOR CODE COMPLIANCE WHICH NEEDS TO BE REVIEWED FOR
 ITEMS SUCH AS DINING ROOMS/AREAS FOR COMPLIANCE PER
 210.52B1, 210.11C1, 220.53 ETC
  
 3) NOTE: PLEASE SEE MISSING LIGHTING REQUIRED IN AHU
 CLOSETS PER 210.70
  
 4) NOTE: PLEASE SEE SOME UNITS ARE STILL MISSING
 REQUIRED RECEPTACLES PER 210.52.
 PLEASE SEE UNIT A WHICH IS ON SHEET E-1 ON THE LEFT
 HAND SIDE. PLEASE SEE THE WALL BETWEEN THE KITCHEN AND
 LIVING ROOM. MANY OF THE LOCATIONS WERE REVISED HOWEVER
 NOT ALL.
 PLEASE ALSO SEE WALL SPACE IN KITCHENS IN UNITS B, C AS
 THERE ARE WALL SPACES GREATER THAN 2 FT.
  
 5) NOTE: PLEASE SEE MISSING LIGHTING CONTROLS REQUIRED
 WHEN ENTERING INTO THE UNITS SUCH AS UNIT *A*. PLEASE
 SEE 210.70 FOR REQUIRED HALLWAY LIGHTING AND CONTROLS
 FOR INGRESS AND EGRESS AND ENTRANCES.
 ** ( THIS NOTE IS NOT FOR OUTSIDE WHEN AUTOMATIC
 OUTSIDE LIGHTING IS BEING PROVIDED.
  
 6) NOTE: PLEASE VERIFY THE AIC RATINGS ON PLANS. PLANS
 STATE 30,000 AIC RATING FOR ALL EQUIPMENT. THIS MAY
 WANT TO BE CONFIRMED. IF PLANS INDICATE 30K FOR ALL
 THEN THIS WILL BE REQUIRED.
 THE LET THROUGH CURRENT ON THE LOAD SIDE OF MAINS
 SHOULD BE VERIFIED WITH THE MANUFACTURE ETC
 110.9.
 RESPONSE CONTAINS QUESTION MARKS.
  
 7) NOTE: PLEASE KNOW NOTES HAVE BEEN ROUTED TO
 *ADDRESSING* AS ADDRESSING OF THE BUILDINGS IS NEEDED.
 THE PERMIT APPLICATION STATES *ELEVEN NEW TOWNHOUSES *
 HOWEVER BY DEFINITION THESE ARE NOT FEE SIMPLE
 TOWNHOUSE UNITS. THESE ARE SHOWN AS MULTI-FAMILY
 BUILDINGS. EACH BUILDING WOULD NEED A SEPARATE
 ADDRESS.
 PLEASE KNOW ONCE THE FINAL ADDRESSES FOR EACH ARE
 DETERMINED PLEASE REVISE TITLE BLOCKS ACCORDINGLY.
 FAC 61G16-1.004, 61G15-23.002, FBC 106.5
  
 8) NOTE: PLEASE SEE NEC 90.8. THE SERVICE AS SHOWN IS A
 400AMP SERVICE WITH A LOAD OF 399.6 AMPS. THIS DOES NOT
 ALLOW FOR ANY FUTURE LOADS NOT EVEN FOR ONE CIRCUIT AS
 SHOWN.
 THE LOAD CALCULATIONS FOR BUILDING *A* STATES A TOTAL
 OF FOUR (4) UNITS HOWEVER BASED ON THE PLANS AND THE
 LOAD CALCULATIONS WHICH INDICATE 5 UNITS PLEASE
 REVISE.
 PLEASE REVISE SERVICE FOR BUILDING *B*.
 NEC 220, 240.4,310.16 ETC
  
 ** AS SOME ITEMS ARE NOT SHOWN, FINAL DETERMINATIONF
 FOR CODE COMPLIANCE CAN NOT BE MADE AT THIS TIME.
  
  
  
  
  
 **IMPORTANT**
 ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP
 FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE
 ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING.
 DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS.
 PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY
 ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS,
 SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO
 TWO SETS/FOLDERS/BINDERS ETC.
 PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS
 SHOULD BE SUBMITTED FOR REFERENCE.
 THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID
 ANY DELAYS.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop ENG ENGINEERING CSD
Rev No 3 Status P Date 2009-04-10 Cont ID  
Sent By mgonzale Date 2009-04-10 Time 08:08 Rev Time 1.00
Received By mgonzale Date 2009-04-10 Time 08:07 Sent To  
Notes
2009-04-10 08:11:38" APPROVED WITH PROVISO "
  
 WATER SERVICES WILL BE COORDINATED AT PRE-CONSTRUCTION
 MEETING
 EOR HAS BEEN ADVISED THAT SERVICE LINES, WATER METERS
 AND BACKFLOWS
 SHALL BE LOCATED TO THE CLOSEST SOURCE AS POSSIBLE.
  
 [email protected]
  
 EMERY FABIAN IS THE ENGINEERING PROJECT COORDINATOR
 ASSIGNED TO THIS PROJECT.
 A PRE-CONSTRUCTION CONFERENCE WITH SUCH ENTITIY MUST ME
 SET BEFORE SETTING
 METER BOXES AND OR NEW WATER SERVICES. (561) 494-1040

Review Stop ENG ENGINEERING CSD
Rev No 2 Status F Date 2009-03-06 Cont ID  
Sent By mgonzale Date 2009-03-06 Time 14:48 Rev Time 1.00
Received By mgonzale Date 2009-03-06 Time 14:07 Sent To  
Notes
2009-03-06 14:47:59**** NOT APPROVED *****
  
 PLEASE CONTACT ENGINEERING SERVICES - PLANS ARE OVER 1
 YEAR OLD.
 WATER SERVICE LINES MUST BE RUN INSIDE OF THE PROPERTY
 AND NOT UNDER THE CITY SIDEWALK.
  
 [email protected] (561) 494-1085
  
  
  

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2008-07-25 Cont ID  
Sent By rchokshi Date 2008-07-25 Time 14:37 Rev Time 0.00
Received By rchokshi Date 2008-07-25 Time 14:29 Sent To  
Notes
2008-07-25 14:37:12FAILED FOR FOLLOWING REASONS:
  
 1. PLEASE PROVIDE A COPY OF NOTICE OF INTENT (NOI).
 PLEASE APPLY AT FDEP, NPDES STORMWATER SECTION FOR
 NOI.
 YOU CAN GET NOI INFO FROM
 WWW.DEP.STATE.FL.US/WATER/STORMWATER/NPDES/
 NOTICE OF INTENT DEP FORM 62-621.300(4)(B),
 EFFECTIVE MAY 1, 2003
  
 2. PLEASE SHOW ON DRAWINGS THE SILT FENCE DETAILS &
 TURBIDITY DETAILS OFPOLLUTION PREVENTION . PLEASE
 SHOW ON DRAWINGS THE TURBIDITY AROUND EACH CATCH BASIN.
 HEIGHT OF FENCE SHOULD BE HIGH ENOUGH PER FDEP TO STOP
 DUST PARTICLES.
  
 3. PLEASE PROVIDE A COPY OF BOND FOR ORDINANCE NO.
 4060-07:
  
 ALL DEMOLITION AND NEW CONSTRUCTION PERMITS, WITH
 EXCEPTION OF SINGLE FAMILY, DUPLEX AND ACCESSORY
 APARTMENT, SHALL POST BONDS OR DEPOSITS FOR THE
 FOLLOWING:
  
 1. EROSION CONTROL, AND
 2. LAND STABILIZATION
  
 THE AMOUNT OF THE EROSION CONTROL AND LAND
 STABILIZATION BONDS SHALL BE DETERMINED BY THE ENGINEER
 OF RECORD USING THE CURRENT CITY COST SCHEDULE AND
 VERIFIED BY THE CITY'S ENGINEERING SERVICES DEPT.
 PLEASE CONTACT BRIAN MOREE, ENG SERVICES CONSTRUCTION
 SUPERVISOR, AT 561- 494 -1040 FOR MORE INFORMATION.
  
 UPON VERTICAL CONSTRUCTION COMMENCEMENT, PAYMENT IN
 FULL OF ALL APPLICABLE FEES, AND COMPLIANCE WITH ALL
 TERMS AND CONDITIONS OF ANY POSTED BOND, THE PERMITTEE
 MAY REQUEST RELEASE OF THE BONDS OR DEPOSITS.
  
 A COPY OF ORDINANCE NO. 4060-07 MAY BE OBTAINED FROM
 THE CITY CLERK'S OFFICE LOCATED ON THE FIRST FLOOR.
  
 4.PLEASE MAKE SURE THAT DUMPSTER LOCATION MUST BE
 ACCESSIBLE FOR PICKUP TRUCK.
  
 5. PLEASE SHOW ON CALCULATION THAT YOU HAVE CONSIDERED
 FLOOD ZONE AREA, & 5,10, 25, 100 YEAR FLOOD CRITERIA
 AND CROWN OF THE ROAD WHEN YOU DETERMINE THE FIRST
 FLOOR ELEVATION. FIRST FLOOR ELEVATION SHOULD BE
 ATLEAST 1 FOOT HIGHER THAN HIGHEST CROWN OF THE ROAD.
  
 6. PLEASE SHOW ON DRAINAGE DRAWINGTHE SITE AREA,
 GREEN, LAKE,PARKING AREA, IMPERVIOUS,PERVIOUS AREAYOU
 ARE DEVELOPING FOR THIS PROJECT . PLEASEMAKE SURE
 THESE AREAS SHOWN ON DRAINAGE DRAWINGS MUST MATCH WITH
 AND USED IN STORM WATER QUALITY CALCULATIONS. PLEASE
 PROVIDE A COPY OF THESE CALCULATIONS.
  
 7. PLEASE SHOW ALL STORM WATER PIPES AROUND YOUR SITE
 SO, WE CANSEE THE LAYOUT OF STORM WATER PIPES FROM
 ALL OTHER STORM WATER PIPES. PLEASE SHOW DETAIL OF THE
 CONTROL STRUCTURESWITH ELEVATIONS, NOTCHES, BLEEDING
 ELEVATION, ETC ON DRAWINGS, CALCULATION FOR
 EXFILTRATION TRENCHES, PLEASE SHOW DRY DETENTION/WET
 DETENTION AREAS IN STORM WATER CALS IF YOU HAVE ALL
 THESE. PLEASE RESUBMIT GEO-TECH REPORT AND ALL
 ENVRONMENTAL REPORT.
  
 8. ALSO PLEASE SHOW ALL CATCH BASINS NEAREST,AROUND
 YOUR SITE FOR STORM WATER DRAIN SO YOUR SITE DO NOT GET
 FLOODED AND HAVE ENOUGH DRAINS.
  
 9. PLEASE PROVIDE A COPY OF SFWMD PERMIT,, GEO-TECH
 REPORT&STORM WATER QUALITY CALCULATIONS TO 1000
 45TH STREET FOR THEIR APPROVAL BEFORE WE APPROVE.
  
 10. WATER & SEWER PLANS MUST BE APPROVED FROM MANNY G.
 OF 1000 45TH STREET BEFORE WE ISSUE A PERMIT.
  
 PLEASE RESPOND EACH ITEM IN DETAIL TO EXPEDITE YOUR
 PERMITTING PROCESS
  
 RASIK CHOKSHI805-6723

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2009-04-24 Cont ID  
Sent By mwennerg Date 2009-04-24 Time 10:38 Rev Time 0.00
Received By mwennerg Date 2009-04-24 Time 10:38 Sent To E
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2009-03-09 Cont ID  
Sent By mwennerg Date 2009-03-09 Time 12:57 Rev Time 0.00
Received By mwennerg Date 2009-03-09 Time 12:57 Sent To  
Notes
2009-03-09 13:04:07***DENIED***
  
 THIS COMMENT IS TAKEN DIRECTLY FROM THE FIRST FIRE PLAN
 REVIEW:
  
 1) 2ND REQUEST: ILLUSTRATE THE LOCATIONS OF NEW AND
 EXISTING FIRE HYDRANTS RELEVANT TO THIS PROJECT. PLEASE
 INDICATE THE DISTANCE FROM THE CLOSEST FIRE HYDRANT TO
 REFERENCED PROPERTY.
  
  
 MIKE WENNERGREN, ASST. FIRE MARSHAL
 FIRE PLAN REVIEW
 FIRE PREVENTION (561) 804-4756

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2008-08-21 Cont ID  
Sent By mwennerg Date 2008-08-21 Time 13:11 Rev Time 0.00
Received By mwennerg Date 2008-08-21 Time 13:11 Sent To  
Notes
2008-08-21 13:17:25***DENIED***
  
 MOST OF THE COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEW
 UNDER THE NOW EXPIRED PERMIT HAVE BEEN ADDRESSED.
 PLEASE SEE THE FOLLOWING COMMENT FROM THE LAST REVIEW
 AND NEW COMMENTS:
  
 1) ILLUSTRATE THE LOCATIONS OF NEW AND EXISTING FIRE
 HYDRANTS. PLEASE ILLUSTRATE ON C- SHEETS.
  
 2) NEW COMMENT- EMERGENCY VEHICLE ACCESS AND WATER
 SUPPLY SHALL COMPLY WITH NFPA 1, 2003.
  
 3) NEW COMMENT- SMOKE ALARMS SHALL BE MINIMUM OF THREE
 (3) FEET FROM AC DIFFUSERS AND COMPLY WITH 101, SEC.
 9.6.2.10 SO THAT THE OPERATION OF ONE (1) SMOKE ALARM
 ACTIVATES ALL SMOKE ALARMS IN THE UNIT.
  
  
 MIKE WENNERGREN, ASSISTANT FIRE MARSHAL
 FIRE PLAN REVIEW
 FIRE PREVENTION (561) 804-4756

Review Stop HIST HISTORICAL
Rev No 1 Status P Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
2009-02-19 12:37:43OK PER G JUDGE 8-21-07 NO FEE CHGD, OK PER J PAPA FOR
 RESUB 1-26-09 CHARGED $10 FEE, OK PER J PAPA TO RESUB
 ON 2-19-09 NO FEE CHARGED.

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2009-10-28 Cont ID  
Sent By jwitmer Date 2009-10-28 Time 13:27 Rev Time 0.00
Received By jwitmer Date 2009-10-28 Time 13:27 Sent To  
Notes
2009-10-28 13:28:46INCOMING TO: R. MC DOUGAL

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2009-09-09 Cont ID  
Sent By shill Date 2009-09-09 Time 13:42 Rev Time 0.00
Received By shill Date 2009-09-09 Time 13:42 Sent To  
Notes
2009-09-09 13:42:34TO LM DESK (TRUSS ENGINEERING)
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2009-02-24 Cont ID  
Sent By adarroug Date 2009-02-24 Time 10:54 Rev Time 0.00
Received By adarroug Date 2009-02-24 Time 10:54 Sent To  
Notes
2009-03-05 19:57:41EXPEDITE REVIEW - AFFORDABLE HOUSING - SEE HCD STAMP ON
 SHEET SP-1
  
  
2009-02-24 10:55:00TO "COMM" BD#8/PLANS ON RACK/LARGE FOLDED PLANS
 W/PAPERWORK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2009-01-28 Cont ID  
Sent By adarroug Date 2009-01-28 Time 09:52 Rev Time 0.00
Received By adarroug Date 2009-01-28 Time 09:52 Sent To  
Notes
2009-01-28 09:52:51TO "COMM" BD#59

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-10-10 Cont ID  
Sent By lmartine Date 2008-08-21 Time 08:57 Rev Time 0.00
Received By lmartine Date 2008-07-23 Time 13:05 Sent To  
Notes
2008-07-23 13:11:58TO "COMM" BD#40

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2009-03-09 Cont ID  
Sent By rregueir Date 2009-03-09 Time 15:47 Rev Time 0.00
Received By rregueir Date 2009-03-09 Time 15:42 Sent To  
Notes
2009-03-09 15:47:09****PROVISO****
 PAGES M-1 THROUGH M-4: NOTE #1 CALLS FOR 1" COPPER PIPE
 TO BE TRANSITIONED TO 3/4 PVC PIPE. CONDENSATE PIPE
 SHALL NOT DECREASE IN SIZE FROM THE DRAIN PAN
 CONNECTION TO THE PLACE OF CONDENSATE DISPOSAL IN
 ACCORDANCE WITH FBC-M 307.2.2. IF PIPE STARTS AS 1" IT
 MUST STAY AT 1". PIPE MAY ALSO START AT 3/4" AS LONG AS
 IT DOES NOT REDUCE IN SIZE. REVISE PLANS PRIOR TO
 INSPECTION TO ADDRESS THIS CONDITION IN ACCORDANCE WITH
 FBC-B 106.4.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT:
 RONALD J. REGUEIRO
 561.805.6719
 [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2008-08-11 Cont ID  
Sent By rregueir Date 2008-08-11 Time 13:28 Rev Time 0.00
Received By rregueir Date 2008-08-11 Time 10:10 Sent To  
Notes
2008-08-11 13:28:02REVIEW #: 2ND
 ACTION: DENIED
  
 REVIEWED UNDER THE FOLLOWING CODES:
  
 FBC 2004 CODE FAMILY W/ 2007 SUPPLEMENTS
 FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH
  
 THE FOLLOWING COMMENTS ARE NUMBERED TO CORRESPOND WITH
 PREVIOUS REVIEW COMMENTS AS WELL AS DESIGNER'S WRITTEN
 RESPONSES FOR THE PURPOSE OF CONTINUITY.
 NOTE: THESE COMMENTS ARE BASED AND NUMBERED ON COMMENTS
 UNDER EXPIRED PERMIT #07080639 DATED 10/31/07.
 ADDITIONAL COMMENTS ARE POSSIBLE. THIS IS A NEW PERMIT
 APPLICATION AND WILL BE REVIEWED ACCORDINGLY.
  
 1. THE JOB DESCRIPTION ON THE PERMIT APPLICATION IS
 STILL DESCRIBING THIS WORK AS TOWNHOUSES. BY DEFINITION
 IN FBCB SECTION 202, THESE ARE NOT TOWNHOUSES AND WILL
 CONTINUE TO BE REVIEWED UNDER THE FBC AS R-2
 MULTI-FAMILY DWELLINGS.
  
 2. ENERGY CODE COMPLIANCE FORMS HAVE BEEN SUBMITTED.
 HOWEVER, THE BUILDING ENVELOPE COMPONENTS SHOWN ON THE
 COMPLIANCE FORM BARE NO RESEMBLANCE TO THE COMPONENTS
 SHOWN ON THE ARCHITECTURAL PLANS. PLEASE SEE BUILDING
 PLAN REVIEW FOR MORE SPECIFIC INFORMATION. ALSO, A
 COOLING AND HEATING LOAD CALCULATION SHALL BE PERFORMED
 ON THE BUILDING AND SHALL BE ATTACHED TO THE FORM 600
 SUBMITTED WHEN APPLICATION IS MADE FOR A BUILDING
 PERMIT IN ACCORDANCE WITH FBCB 13-607.1.ABC.1. COOLING
 EQUIPMENT CAPACITY SHALL BE DETERMINED IN ACCORDANCE
 WITH 13-607.1.ABC.1.1.
  
 3. OK
  
 4. OK
  
 5. OK
  
 6. PAGE M-5 SHOWS A PRESCRIPTIVE TIE-DOWN METHOD PER
 FBCB 301.13.1. PLEASE NOTE THAT 301.13.1 IS ONLY
 APPLICABLE TO R-3 OCCUPANCIES. AS STATED IN COMMENT #1
 ABOVE, THESE BUILDINGS ARE CLASSIFIED AS R-2
 OCCUPANCIES. THEREFORE, AN ENGINEERED DESIGN OF
 ATTACHMENT WITH SUPPORTING WIND LOAD CALCULATIONS IS
 REQUIRED IN ACCORDANCE WITH FBCM 301.13. PLEASE PROVIDE
 THE REQUESTED INFORMATION AND RESUBMIT.
  
 7. PAGE M-1 THROUGH M-4 CALL FOR 1 INCH CPVC PIPE TO BE
 USED FOR CONDENSATE. SUPPORTING DOCUMENTATION WAS
 REQUESTED SHOWING THAT THE SPECIFIED SIZE OF CPVC WOULD
 MEET THE 25/50 RATING WHEN TESTED IN ACCORDANCE WITH
 ASTM E84 PER FBCM 602.2.1. NO SUCH DOCUMENTATION WAS
 PROVIDED. THE ONLINE DOCUMENTATION WHICH WAS RESEARCHED
 DURING THIS REVIEW INDICATES THAT ONLY 1/2 INCH AND 3/4
 INCH CPVC HAS MET THE 25/50 REQUIREMENT WHEN NOT FILLED
 WITH WATER. CONDENSATE DRAIN PIPES ARE NOT FILLED WITH
 WATER AND THEREFORE 1 INCH CPVC IS NOT ACCEPTABLE IN
 THE PLENUM SPACES PER FBCM 602.2.1. PLEASE BE REMINDED
 THAT 3/4 INCH CPVC DOES NOT MEET THE INTERNAL DIAMETER
 REQUIREMENTS OF FBCM 307.2.2. PLEASE SHOW A CONDENSATE
 DRAIN MATERIAL WITHIN THE PLENUM SPACE WHICH MEETS THE
 REQUIREMENTS OF BOTH CODE SECTIONS REFERENCED ABOVE.
  
 8. OK
  
 NEW COMMENTS:
  
 9. PAGES M-1 THROUGH M-4 SHOW PLAN NOTE #3 WHICH CALLS
 FOR BATHROOM AND DRYER EXHAUST TO TERMINATE ON THE ROOF
 AT A GOOSENECK WITH BACK DRAFT DAMPER AND BIRD SCREEN.
 DRYER EXHAUST DUCTS FOR CLOTHES DRYERS SHALL TERMINATE
 ON THE OUTSIDE OF THE BUILDING AND SHALL BE EQUIPPED
 WITH A BACKDRAFT DAMPER. SCREENS SHALL NOT BE INSTALLED
 AT THE DUCT TERMINATION IN ACCORDANCE WITH FBCM 504.4.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT:
 RONALD J. REGUEIRO
 561.805.6719
 [email protected]

Review Stop P PLUMBING
Rev No 2 Status P Date 2009-04-09 Cont ID  
Sent By kstevens Date 2009-04-09 Time 14:18 Rev Time 0.00
Received By kstevens Date 2009-04-09 Time 14:18 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2008-08-05 Cont ID  
Sent By kstevens Date 2008-08-05 Time 08:19 Rev Time 0.00
Received By kstevens Date 2008-08-05 Time 08:19 Sent To  
Notes
2008-08-05 09:47:41DENIED
 REFERENCE: FBC-2004 PLUMBING
  
 1. SHT P-1 SHOWS VENTS AT THE CURB OF THE SHOWER IN
 UNITS "A". PLEASE CLARIFY. WILL THIS BE A SOLID WALL
 WITH A DOOR? 106.1.2.
  
 2. SHT P-2 TUBS INDICATED AS SHOWERS IN THE MASTER
 BATHROOMS OF "A" & "B" UNITS ARE NOT VENTED. SECTION
 901.2.1.
  
 3. SHT P-3 THE WASH MACHINES IN THE "B" UNITS AND ONE
 "C" UNIT SHALL DISCHARGE DOWNSTREAM OF THE HORIZONTAL
 WET VENT FOR THE BATHROOM FIXTURES. SECTION 909.1.
  
 4. SHT P-3 THE FLOOR PLANS FOR THE WASH MACHINES AND
 WATER HEATERS ARE DIFFERENT IN BOTH "C" UNITS. AS SUCH
 SEPARATE RISER DIAGRAMS REFLECTING THE DIFFERENT FLOOR
 PLANS WILL BE REQUIRED FOR THE SANITARY AND WATER
 ISOMETRICS. SECTION 106.3.5.1.3.
  
 5. SHT P-4 TUBS INDICATED AS SHOWERS IN THE MASTER
 BATHROOMS OF THE "B" UNITS ARE NOT VENTED. SECTION
 901.2.1.
  
 6. SHT P-5 SANITARY RISER DIAGRAM UNIT "A"DOES NOT
 REFLECT THE FLOOR PLAN FIRST FLOOR. THE VENT AT THE
 SHOWER IS NOT SHOWN AND AS SUCH IS NOT VENTED. THE
 "SHOWER" FOR THE MASTER BATH IS NOT VENTED. (THIS IS
 SHOWN AS A TUB ON THE FLOOR PLAN). SECTIONS 106.1.1 &
 901.2.1.
  
 7. SHT P-5 SANITARY RISER DIAGRAM UNIT "B"DOES NOT
 REFLECT THE FLOOR PLAN FIRST FLOOR. THE WASH MACHINE IS
 SHOWN CONNECTING DOWNSTREAM OF THE WATER CLOSET ON THE
 FLOOR PLAN, BUT BETWEEN THE WATER CLOSET AND LAV ON THE
 RISER DIAGRAM. (SEE SECTION 909.1). THE MASTER BATH
 SHOWER, (SHOWN AS A TUB ON THE FLOOR PLAN), IS NOT
 VENTED. SECTIONS 106.1.1 & 901.2.1.
  
 8. SHT P-5 SANITARY RISER DIAGRAM UNIT "C" DOES NOT
 REFLECT THE FLOOR PLAN FIRST FLOOR. THE STACK FOR THE
 SECOND FLOOR BATHROOM IS SHOWN CONNECTING TO THE BRANCH
 LINE TO THE POWDER ROOM ON THE FLOOR PLAN, BUT ON THE
 BRANCH LINE TO THE WASH MACHINE ON THE RISER DIAGRAM.
 ALSO THE WASH MACHINE IS SHOWN UPSTREAM OF THE KITCHEN
 SINK ON THE FLOOR PLAN BUT DOWNSTREAM OF THE KITCHEN
 SINK ON THE RISER DIAGRAM. PLEASE CORRELATE. SECTIONS
 106.1.1 & 710.1.
  
 9. SHT P-6 WATER RISER DIAGRAM UNIT "A" DOES NOT
 REFLECT THE FLOOR PLAN AT THE WATER HEATER. FLOOR PLAN
 SHOWS THE WATER HEATER BETWEEN THE BATHROOM FIXTURES
 AND THE WASH MACHINE BUT THE RISER DIAGRAM SHOWS THE
 WATER HEATER PAST THE KITCHEN SINK BRANCH LINE. PLEASE
 CORRELATE. SECTIONS 106.1.1 & 604.1.
  
 10. SHT P-6 WATER RISER DIAGRAM UNIT "C" DOES NOT
 REFLECT THE FLOOR PLAN AT THE WATER HEATER. FLOOR PLAN
 SHOWS THE WATER HEATER BETWEEN THE BATHROOM FIXTURES
 AND THE WASH MACHINE BUT THE RISER DIAGRAM SHOWS THE
 WATER HEATER PAST THE KITCHEN SINK AND THE WASH MACHINE
 BRANCH LINES. PLEASE CORRELATE. SECTIONS 106.1.1 &
 604.1.
  
 11. SHT P-6 ALL WATER RISER DIAGRAMS. WATER HAMMER
 ARRESTORS ARE REQUIRED AT THE WASH MACHINES, DISH
 WASHERS & ICE MAKERS (REF) PER SECTION 604.9. THE WATER
 HAMMER ARRESTORS SHALL BE LOCATED NEAR THE FIXTURES IN
 AN "EFFECTIVE RANGE" (NOT IN THE CEILING). PDI-WH 201.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 2 Status P Date 2009-03-06 Cont ID  
Sent By kdfreema Date 2009-03-06 Time 16:48 Rev Time 0.00
Received By kdfreema Date 2009-03-06 Time 16:48 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2008-07-30 Cont ID  
Sent By kdfreema Date 2008-07-30 Time 13:41 Rev Time 0.00
Received By kdfreema Date 2008-07-30 Time 13:41 Sent To  
Notes
2008-07-30 14:42:31***FAILED***
  
 1. THE PLANS TO NOT BEAR THE REVIEW STAMP OF THE
 HISTORIC PRESERVATION DIVISION, THEY MUST REVIEW AND
 STAMP THE PLANS BEFORE SUBMITTAL.
  
 2. PLEASE PROVIDED DOCUMENTATION THAT THE BOND RELATING
 TO THE REDESIGNATION OF THE ALLEY TO THE NORTH AS
 ONE-WAY HAS BEEN PAID.
  
 3. ADDRESS CHARACTERS MUST BE A MINIMUM OF 6 INCHES IN
 HEIGHT.
  
 4. CONSIDER RELOCATING THE PROPOSED BIKE RACK TO THE
 INSIDE OF THE FENCE. THE PROPOSED LOCATIONS LEAVES THE
 BICYCLES MORE PRONE TO THEFT.
  
 5. CONSIDER ADDING A SECOND HEAD TO THE
 SOUTHEASTERN-MOST POLE LIGHT TO ILLUMINATE THE
 RECREATION/OPEN SPACE AS A MEANS TO DETER LOITERING IN
 THAT SPACE AFTER DARK.
  
 PLEASE CONTACT KELLY FREEMAN, PLANNER, AT 822-1458 OR
 [email protected] WITH QUESTIONS.