| Plan Review Stops For Permit 08070608 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2008-11-06 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2008-11-06 |
Time |
14:31 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2008-11-06 |
Time |
14:31 |
Sent To |
|
|
| Notes |
| 2008-11-06 14:32:23 | ADDED STRUCTURAL REPAIR DETAIL AS REQUESTED BY | | | INSPECTOR TO SHEET A1. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2008-08-25 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2008-08-25 |
Time |
09:54 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2008-08-25 |
Time |
09:54 |
Sent To |
|
|
| Notes |
| 2008-08-25 09:54:22 | BUILDING PROVISO | | | | | | 1) SUBMIT 2 COPIES OF PRODUCT APPROVALS FOR THE ROOF | | | SHINGLES THAT HAVE BEEN APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD. | | | | | | 2) ADDITIONAL STRUCTURAL DRAWINGS OR CALCULATIONS MAY | | | BE REQUIRED BY THE FIELD INSPECTOR AS THE JOB | | | PROGRESSES. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-07-29 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2008-07-29 |
Time |
16:23 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2008-07-29 |
Time |
16:23 |
Sent To |
|
|
| Notes |
| 2008-07-29 14:45:18 | 2004 FBC W/2007 REVISIONS | | | REPAIR FIRE DAMAGE/REPLACE WINDOWS | | | | | | 1)A RECORDED COPY OF THE NOTICE OF COMMENCEMENT WILL | | | BE REQUIRED. | | | | | | 2) THE BUILDING DESIGN DATA ON SHEET CVR-1 SPECIFIES A | | | 1 STORY STRUCTURE AND PLANS ARE FOR A TWO STORY. PLEASE | | | CORRECT. ALSO REVISE CODE REFERENCE TO THE 2004 FBC | | | WITH 2007 REVISIONS. | | | | | | 3) SPECIFY THE ROOF TRUSS/ RAFTER SPACING ON THE | | | FRAMING PLAN ON SHEET A3. FBC R801.2 | | | | | | 4) PLEASE CLARIFY IF THE REPAIRED AREA OF THE ROOF IS | | | ENGINEERED TRUSSES OR CONVENTIONAL ROOF FRAMING. THE | | | DETAILS AND NOTES REFER TRUSSES AND COMMON FRAMING. IF | | | CONVENTIONAL ROOF FRAMING SPECIFY THE RAFTER AND JOIST | | | SPANS AND BEARING WALL LOCATIONS. SHOW COMPLIANCE WITH | | | R801.2 REQUIREMENTS. ROOF AND CEILING CONSTRUCTION | | | SHALL BE CAPABLE OF ACCOMMODATING ALL LOADS IMPOSED | | | ACCORDING TO SECTION R301 AND OF TRANSMITTING THE | | | RESULTING LOADS TO THE SUPPORTING STRUCTURAL ELEMENTS. | | | | | | | | | 5) SHOW COMPLIANCE WITH R803.2.3.1 SHEATHING | | | FASTENINGS. WOOD STRUCTURAL PANEL SHEATHING SHALL BE | | | FASTENED TO ROOF FRAMING WITH 8D RING-SHANK NAILS AT 6 | | | INCHES ON CENTER AT EDGES AND 6 INCHES ON CENTER AT | | | INTERMEDIATE FRAMING. | | | | | | 6) THE MECHANICAL DRAWING M1 SPECIFIES THE AIR HANDLER | | | HANGING FROM THE TRUSSES OR 2X4 RAFTERS. PROVIDE | | | CALCULATIONS INDICATING THAT THE TRUSSES OR RAFTERS CAN | | | SUPPORT THE AIR HANDLER. R801.2 | | | | | | 7) SUBMIT TWO COPIES OF PRODUCT APPROVALS FOR THE | | | STRUCTURAL WINDOW MULLIONS THAT HAVE BEEN REVIEWED AND | | | APPROVED IN WRITING BY THE DESIGNER OF RECORD AS | | | REQUIRED BY RULE 9B-72 AND FBC 106.3.3* CITY | | | AMENDMENTS. | | | | | | 8) ADDITIONAL STRUCTURAL DRAWINGS OR CALCULATIONS MAY | | | BE REQUIRED BY THE FIELD INSPECTOR AS THE JOB | | | PROGRESSES. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2008-08-21 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-08-21 |
Time |
15:57 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-08-21 |
Time |
15:44 |
Sent To |
B |
|
| Notes |
| 2008-08-21 15:58:40 | TO ROBBIE'S DESK./WRT. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2008-07-23 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-07-23 |
Time |
16:18 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-07-23 |
Time |
15:46 |
Sent To |
M |
|
| Notes |
| 2008-07-23 16:17:40 | | | | NONCOMPLIANT | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE | | | CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2004 | | | RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002, | | | NFPA-101 2003, 2004 FBC CHAPTER 1 AS AMENDED AND FOUND | | | NONCOMPLIANT WITH THE FOLLOWING: | | | | | | 1}PLEASE LOCATE ALL SERVICE EQUIPMENT ON THE PLAN, | | | METER ENCLOSURE, DISCONNECTS AND PANELS, SO THAT | | | COMPLIANCE WITH ARTICLES 225 AND 230 CAN BE REVIEWED. | | | | | | 2} SHOW THE LOCATION OF THE A/C EQUIPMENT ON THE PLAN. | | | ALSO SHOW COMPLIANCE WITH THE REQUIRED DISCONNECT PER | | | 440.14,RECEPTACLE PER 210.63, LIGHT PER 210.70(A) | | | (3). | | | | | | 3} THE 2005 NEC WAS ADOPTED BY THE FLORIDA LEGISLATURE | | | EFFECTIVE 8 DECEMBER 2006. THE APPLICATION FOR THIS | | | PROJECT WAS AFTER THAT DATE AND THE PLANS ARE SUBJECT | | | TO THAT CODE. PLEASE CHANGE ALL NOTES TO REFLECT THIS | | | CHANGE.SHEET E1 | | | | | | PLEASE NOTE AN ELECTRICAL PERMIT IS REQUIRED FOR THE | | | SCOPE OF WORK PURPOSED. 105.1 FBC AS AMENDED. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW. | | | CITY OF WEST PALM BEACH | | | 561/805-6718 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-11-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-11-05 |
Time |
11:12 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-11-05 |
Time |
11:12 |
Sent To |
B |
|
| Notes |
| 2008-11-05 11:12:45 | TO "RMCDOUGAL" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-08-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-08-08 |
Time |
14:30 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-08-08 |
Time |
14:30 |
Sent To |
|
|
| Notes |
| 2008-08-15 09:43:18 | PLANS AT TOM G. DESK. | | 2008-08-08 14:31:06 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-07-29 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2008-07-29 |
Time |
16:23 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2008-07-22 |
Time |
11:31 |
Sent To |
|
|
| Notes |
| 2008-07-22 11:32:10 | TO "SFR" "E" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2008-08-15 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-08-15 |
Time |
11:14 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2008-08-15 |
Time |
11:14 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2008-07-24 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-07-24 |
Time |
09:38 |
Rev Time |
0.40 |
| Received By |
tgordon |
Date |
2008-07-24 |
Time |
09:38 |
Sent To |
P |
|
| Notes |
| 2008-07-24 10:02:27 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | *** DENIED *** | | | 1) MECHANICAL PLAN M-1 SHOWS THE AIR HANDLER UNIT ON | | | TOP OF THE ATTIC ACCESS, THE UNIT MUST BE SERVICEABLE | | | PER 2004 FBC/R M1305.1.3. PLEASE CORRECT. | | | | | | 2) MECHANICAL PLAN SECOND FLOOR SHOWS NO DUCT (FLEX) | | | GOING TO THE 14X14 R/A GRILL NEAR THE STAIRWAY. PLEASE | | | CORRECT PER 2004 FBC/R M1602.4 AND FBC 106.1.1. | | | | | | 3) SHOW THE LOCATION OF THE A/C CONDENSER UNIT ON THE | | | MECHANICAL PLAN AND STATE IF NEW OR EXISTING, PER 2004 | | | FBC 106.1.1. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2008-07-29 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2008-07-29 |
Time |
16:29 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2008-07-29 |
Time |
16:29 |
Sent To |
|
|
| Notes |
| 2008-07-29 16:30:51 | NO PLUMBING PLANS SUBMITTED AND NO PLUMBING CONTRACTOR | | | ON APPLICATION. |
|
|