Plan Review Details - Permit 08070532
Plan Review Stops For Permit 08070532
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2008-09-16 Cont ID  
Sent By mjacobs Date 2008-09-16 Time 06:57 Rev Time 0.00
Received By mjacobs Date 2008-09-16 Time 06:46 Sent To PC
Notes
2008-09-16 06:50:23PROCESS PLANS

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2008-09-15 Cont ID  
Sent By mjacobs Date 2008-09-15 Time 11:59 Rev Time 0.00
Received By mjacobs Date 2008-09-15 Time 09:39 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-08-05 Cont ID  
Sent By mjacobs Date 2008-08-05 Time 13:01 Rev Time 0.00
Received By mjacobs Date 2008-08-04 Time 15:21 Sent To PC
Notes
2008-08-05 13:00:59BUILDING PLAN REVIEW
 PERMIT: 08070532
 ADD: 1101 S. FLAGLER DR.
 CONT: CREATIVE CONSTRUCTION CORP.
 TEL: (561)842-5311
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 8-5-08
 REVIEW: 1ST
 ACTION: DENIED
  
 1) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE & REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 2) PROVIDE A DOOR SCHEDULE FOR THE NEW DOORS INDICATING
 THE TYPES OF LOCKS, FIRE RATING AND THE AMOUNT OF
 GLAZING PER DOOR IN ACCORDANCE WITH TABLE 715.4.3.
  
 3) 715.3.3 DOORS LOCATED IN CORRIDORS WALLS OR SMOKE
 BARRIER WALLS HAVING A FIRE-RESISTANCE RATING IN
 ACCORDANCE WITH TABLE 715.3 SHALL BE TESTED IN
 ACCORDANCE WITH NFPA 252 OR UL 10C.
  
 4) IS ANY OF THE CMU WALL BEING DEMOED LOAD BEARING
 WALLS? PROVIDE DETAIL DRAWINGS SHOWING THESE WALLS
 BEING DEMOED WILL NOT AFFECT THE MAIN STRUCTURE. ALSO,
 SHOW THE WALLS WERE ATTACHED TO THE STRUCTURE ABOVE.
 ADDITIONAL INFORMATION REQUIRED 106.1.2*
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 (561)805-6726
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2008-07-22 Cont ID  
Sent By btrobaug Date 2008-07-22 Time 16:18 Rev Time 0.00
Received By btrobaug Date 2008-07-22 Time 16:16 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2008-09-15 Cont ID  
Sent By mawillia Date 2008-09-15 Time 14:30 Rev Time 0.00
Received By mawillia Date 2008-09-15 Time 14:11 Sent To B1
Notes
2008-09-15 14:30:24*****APPROVED*****
  
  
 THE COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEW HAVE
 BEEN ADDRESSED; PLAN SHEETS 2 AND 3 (OF 4) WERE
 STAMPED, INITIALED, AND DATED.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2008-08-01 Cont ID  
Sent By mwennerg Date 2008-08-01 Time 14:14 Rev Time 0.00
Received By mwennerg Date 2008-08-01 Time 14:14 Sent To  
Notes
2008-08-01 14:34:19***DENIED***
  
 1) SHEET TWO ON LIFE SAFETY PLAN ILLUSTRATES AN
 EXISTING FIRE ALARM HORN. ARE THERE VISUAL APPLIANCES
 IN THIS AREA?
  
 2) A DOOR LOCATED BETWEEN THE MUSIC ROOM AND AN
 EXISTING OFFICE SUITE IS NOT INDICATED AS AN EXIT DOOR,
 BUT SHOW AN EGRESS CAPACITY OF 135. EGRESS DOORS SHALL
 BE MARKED AND SHALL SWING IN THE DIRECTION OF TRAVEL
 WHERE SERVING (50) OR MORE OCCUPANTS. IF NOT AN EXIT
 DOOR, PLEASE REMOVE ANY REFERENCE TO EGRESS.
 ADDITIONALLY, PLEASE PROVIDE DOOR WIDTHS TO SUPPORT THE
 EGRESS CAPACITY CALCULATIONS ON THE DRAWINGS.
  
 3) EGRESS DOOR SERVING A ROOM OR AREA WITH GREATER THAN
 (100) OCCUPANTS, SHALL BE PROVIDED WITH PANIC OR FIRE
 EXIT HARDWARE. PLEASE PROVIDE A DOOR SCHEDULE.
  
 4) NOTE ON SHEET THREE INDICATES FIRE SPRINKLER TO
 REMAIN. IF SYSTEM IS TO BE ALTERED, SEPARATE SHOP
 DRAWINGS AND PERMIT REQUIRED.
  
 5) LIFE SAFETY TO COMPLY WITH NFPA 101, 2003.
  
 6) CONSTRUCTION, ALTERATION AND DEMOLITION TO COMPLY
 WITH NFPA 241.
  
  
 MIKE WENNERGREN, ASSISTANT FIRE MARSHAL
 FIRE PLAN REVIEW
 FIRE PREVENTION (561) 804-4756

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-09-11 Cont ID  
Sent By adarroug Date 2008-09-11 Time 10:00 Rev Time 0.00
Received By adarroug Date 2008-09-11 Time 10:00 Sent To  
Notes
2008-09-11 10:01:53TO "BOB"#4

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2008-08-05 Time   Rev Time 0.00
Received By adarroug Date 2008-07-18 Time 14:53 Sent To  
Notes
2008-07-21 16:14:46TO "BOB"#4
2008-07-18 14:53:17WAITING FOR "BOB"

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2008-09-11 Cont ID  
Sent By tgordon Date 2008-09-11 Time 13:31 Rev Time 0.30
Received By tgordon Date 2008-09-11 Time 13:31 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2008-08-01 Cont ID  
Sent By tgordon Date 2008-08-01 Time 15:48 Rev Time 0.25
Received By tgordon Date 2008-08-01 Time 15:48 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2008-07-23 Cont ID  
Sent By tgordon Date 2008-07-23 Time 11:47 Rev Time 1.45
Received By tgordon Date 2008-07-23 Time 11:47 Sent To  
Notes
2008-07-23 12:20:14PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM
 BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA
 ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES
 (F.S.).
  
 *** DENIED ***
 1) PLAN TWO OF 4 SHOWS TWO 20X30 R/A TRANSFER GRILLS
 OPEN TO THE CORRIDOR, PER 2004 FBC 1016.1 CORRIDORS
 SHALL BE FIRE-RESISTANCE RATED IN ACCORDANCE WITH TABLE
 1016.1. THE CORRIDOR WALLS REQUIRED TO BE
 FIRE-RESISTANCE RATED SHALL COMPLY WITH SECTION 708 FOR
 FIRE PARTITIONS, OR MEET THE EXCEPTIONS. AND PER
 MECHANICAL CODE 607.5.3 DUCT PENETRATIONS IN FIRE
 PARTITIONS SHALL BE PROTECTED WITH APPROVED FIRE
 DAMPERS INSTALLED IN ACCORDANCE WITH THEIR LISTING.
 PLEASE CORRECT OR ADDRESS COMMENT.
  
 2) PER 2004 FBC 716.5.4.1 CORRIDORS.
 A LISTED SMOKE DAMPER DESIGNED TO RESIST THE PASSAGE OF
 SMOKE SHALL BE PROVIDED AT EACH POINT A DUCT OR AIR
 TRANSFER OPENING PENETRATES A CORRIDOR ENCLOSURE
 REQUIRED TO HAVE SMOKE AND DRAFT CONTROL DOORS IN
 ACCORDANCE WITH SECTION 715.3.3. AND PER MECHANICAL
 CODE 607.5.4 CORRIDORS/SMOKE BARRIERS. A LISTED SMOKE
 DAMPER DESIGNED TO RESIST THE PASSAGE OF SMOKE SHALL BE
 PROVIDED AT EACH POINT A DUCT OR AIR TRANSFER OPENING
 PENETRATES A SMOKE BARRIER WALL OR A CORRIDOR ENCLOSURE
 REQUIRED TO HAVE SMOKE AND DRAFT CONTROL DOORS IN
 ACCORDANCE WITH THE FLORIDA BUILDING CODE, BUILDING.
 SMOKE DAMPERS AND SMOKE DAMPER ACTUATION METHODS SHALL
 COMPLY WITH SECTION 607.5.4.1 OR MEET THE EXCEPTIONS.
 PLEASE CORRECT OR ADDRESS COMMENT.
  
 3) PLEASE SHOW THE CFM'S AT ALL NEW SUPPLY AIR GRILLS,
 PER 2004 FBC/M 603.2.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]

Review Stop P PLUMBING
Rev No 1 Status N Date 2008-08-04 Cont ID  
Sent By mperson Date 2008-08-04 Time 14:35 Rev Time 0.00
Received By mperson Date 2008-08-04 Time 14:35 Sent To  
Notes
2008-08-04 14:37:15NOTE: PROPOSED PLANS ARE NOT INDICATING ANY PLUMBING
 WORK AND THERE HAS BEEN NO PLUMBING PERMIT APPLIED FOR.
 *MRPERSON.

Review Stop Z ZONING
Rev No 1 Status N Date 2008-07-24 Cont ID  
Sent By adavila Date 2008-07-24 Time 17:07 Rev Time 0.00
Received By adavila Date 2008-07-24 Time 17:07 Sent To  
Notes
2008-07-24 17:09:03PERMIT FOR INTERIOR WORK AND REMODELING ONLY.NO SITE
 OR EXTERIOR WORK TO BE INCLUDED WITH THIS PERMIT.
  
 COMMENTS/QUESTIONS CONTACT ANDREINA DAVILA Q. OR
 ANGELLA VANN, DEPUTY PLANNING DIRECTOR, AT (561)
 822-1435.
  