| Plan Review Stops For Permit 08070532 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2008-09-16 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-09-16 |
Time |
06:57 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-09-16 |
Time |
06:46 |
Sent To |
PC |
|
| Notes |
| 2008-09-16 06:50:23 | PROCESS PLANS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2008-09-15 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-09-15 |
Time |
11:59 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-09-15 |
Time |
09:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-08-05 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-08-05 |
Time |
13:01 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-08-04 |
Time |
15:21 |
Sent To |
PC |
|
| Notes |
| 2008-08-05 13:00:59 | BUILDING PLAN REVIEW | | | PERMIT: 08070532 | | | ADD: 1101 S. FLAGLER DR. | | | CONT: CREATIVE CONSTRUCTION CORP. | | | TEL: (561)842-5311 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 8-5-08 | | | REVIEW: 1ST | | | ACTION: DENIED | | | | | | 1) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE & REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 2) PROVIDE A DOOR SCHEDULE FOR THE NEW DOORS INDICATING | | | THE TYPES OF LOCKS, FIRE RATING AND THE AMOUNT OF | | | GLAZING PER DOOR IN ACCORDANCE WITH TABLE 715.4.3. | | | | | | 3) 715.3.3 DOORS LOCATED IN CORRIDORS WALLS OR SMOKE | | | BARRIER WALLS HAVING A FIRE-RESISTANCE RATING IN | | | ACCORDANCE WITH TABLE 715.3 SHALL BE TESTED IN | | | ACCORDANCE WITH NFPA 252 OR UL 10C. | | | | | | 4) IS ANY OF THE CMU WALL BEING DEMOED LOAD BEARING | | | WALLS? PROVIDE DETAIL DRAWINGS SHOWING THESE WALLS | | | BEING DEMOED WILL NOT AFFECT THE MAIN STRUCTURE. ALSO, | | | SHOW THE WALLS WERE ATTACHED TO THE STRUCTURE ABOVE. | | | ADDITIONAL INFORMATION REQUIRED 106.1.2* | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | (561)805-6726 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2008-07-22 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-07-22 |
Time |
16:18 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-07-22 |
Time |
16:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2008-09-15 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-09-15 |
Time |
14:30 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-09-15 |
Time |
14:11 |
Sent To |
B1 |
|
| Notes |
| 2008-09-15 14:30:24 | *****APPROVED***** | | | | | | | | | THE COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEW HAVE | | | BEEN ADDRESSED; PLAN SHEETS 2 AND 3 (OF 4) WERE | | | STAMPED, INITIALED, AND DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2008-08-01 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-08-01 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-08-01 |
Time |
14:14 |
Sent To |
|
|
| Notes |
| 2008-08-01 14:34:19 | ***DENIED*** | | | | | | 1) SHEET TWO ON LIFE SAFETY PLAN ILLUSTRATES AN | | | EXISTING FIRE ALARM HORN. ARE THERE VISUAL APPLIANCES | | | IN THIS AREA? | | | | | | 2) A DOOR LOCATED BETWEEN THE MUSIC ROOM AND AN | | | EXISTING OFFICE SUITE IS NOT INDICATED AS AN EXIT DOOR, | | | BUT SHOW AN EGRESS CAPACITY OF 135. EGRESS DOORS SHALL | | | BE MARKED AND SHALL SWING IN THE DIRECTION OF TRAVEL | | | WHERE SERVING (50) OR MORE OCCUPANTS. IF NOT AN EXIT | | | DOOR, PLEASE REMOVE ANY REFERENCE TO EGRESS. | | | ADDITIONALLY, PLEASE PROVIDE DOOR WIDTHS TO SUPPORT THE | | | EGRESS CAPACITY CALCULATIONS ON THE DRAWINGS. | | | | | | 3) EGRESS DOOR SERVING A ROOM OR AREA WITH GREATER THAN | | | (100) OCCUPANTS, SHALL BE PROVIDED WITH PANIC OR FIRE | | | EXIT HARDWARE. PLEASE PROVIDE A DOOR SCHEDULE. | | | | | | 4) NOTE ON SHEET THREE INDICATES FIRE SPRINKLER TO | | | REMAIN. IF SYSTEM IS TO BE ALTERED, SEPARATE SHOP | | | DRAWINGS AND PERMIT REQUIRED. | | | | | | 5) LIFE SAFETY TO COMPLY WITH NFPA 101, 2003. | | | | | | 6) CONSTRUCTION, ALTERATION AND DEMOLITION TO COMPLY | | | WITH NFPA 241. | | | | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | | FIRE PLAN REVIEW | | | FIRE PREVENTION (561) 804-4756 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-09-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-09-11 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-09-11 |
Time |
10:00 |
Sent To |
|
|
| Notes |
| 2008-09-11 10:01:53 | TO "BOB"#4 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2008-08-05 |
Time |
|
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-07-18 |
Time |
14:53 |
Sent To |
|
|
| Notes |
| 2008-07-21 16:14:46 | TO "BOB"#4 | | 2008-07-18 14:53:17 | WAITING FOR "BOB" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2008-09-11 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-09-11 |
Time |
13:31 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2008-09-11 |
Time |
13:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2008-08-01 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-08-01 |
Time |
15:48 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2008-08-01 |
Time |
15:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2008-07-23 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-07-23 |
Time |
11:47 |
Rev Time |
1.45 |
| Received By |
tgordon |
Date |
2008-07-23 |
Time |
11:47 |
Sent To |
|
|
| Notes |
| 2008-07-23 12:20:14 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | *** DENIED *** | | | 1) PLAN TWO OF 4 SHOWS TWO 20X30 R/A TRANSFER GRILLS | | | OPEN TO THE CORRIDOR, PER 2004 FBC 1016.1 CORRIDORS | | | SHALL BE FIRE-RESISTANCE RATED IN ACCORDANCE WITH TABLE | | | 1016.1. THE CORRIDOR WALLS REQUIRED TO BE | | | FIRE-RESISTANCE RATED SHALL COMPLY WITH SECTION 708 FOR | | | FIRE PARTITIONS, OR MEET THE EXCEPTIONS. AND PER | | | MECHANICAL CODE 607.5.3 DUCT PENETRATIONS IN FIRE | | | PARTITIONS SHALL BE PROTECTED WITH APPROVED FIRE | | | DAMPERS INSTALLED IN ACCORDANCE WITH THEIR LISTING. | | | PLEASE CORRECT OR ADDRESS COMMENT. | | | | | | 2) PER 2004 FBC 716.5.4.1 CORRIDORS. | | | A LISTED SMOKE DAMPER DESIGNED TO RESIST THE PASSAGE OF | | | SMOKE SHALL BE PROVIDED AT EACH POINT A DUCT OR AIR | | | TRANSFER OPENING PENETRATES A CORRIDOR ENCLOSURE | | | REQUIRED TO HAVE SMOKE AND DRAFT CONTROL DOORS IN | | | ACCORDANCE WITH SECTION 715.3.3. AND PER MECHANICAL | | | CODE 607.5.4 CORRIDORS/SMOKE BARRIERS. A LISTED SMOKE | | | DAMPER DESIGNED TO RESIST THE PASSAGE OF SMOKE SHALL BE | | | PROVIDED AT EACH POINT A DUCT OR AIR TRANSFER OPENING | | | PENETRATES A SMOKE BARRIER WALL OR A CORRIDOR ENCLOSURE | | | REQUIRED TO HAVE SMOKE AND DRAFT CONTROL DOORS IN | | | ACCORDANCE WITH THE FLORIDA BUILDING CODE, BUILDING. | | | SMOKE DAMPERS AND SMOKE DAMPER ACTUATION METHODS SHALL | | | COMPLY WITH SECTION 607.5.4.1 OR MEET THE EXCEPTIONS. | | | PLEASE CORRECT OR ADDRESS COMMENT. | | | | | | 3) PLEASE SHOW THE CFM'S AT ALL NEW SUPPLY AIR GRILLS, | | | PER 2004 FBC/M 603.2. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2008-08-04 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-08-04 |
Time |
14:35 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-08-04 |
Time |
14:35 |
Sent To |
|
|
| Notes |
| 2008-08-04 14:37:15 | NOTE: PROPOSED PLANS ARE NOT INDICATING ANY PLUMBING | | | WORK AND THERE HAS BEEN NO PLUMBING PERMIT APPLIED FOR. | | | *MRPERSON. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2008-07-24 |
|
|
Cont ID |
|
| Sent By |
adavila |
Date |
2008-07-24 |
Time |
17:07 |
Rev Time |
0.00 |
| Received By |
adavila |
Date |
2008-07-24 |
Time |
17:07 |
Sent To |
|
|
| Notes |
| 2008-07-24 17:09:03 | PERMIT FOR INTERIOR WORK AND REMODELING ONLY.NO SITE | | | OR EXTERIOR WORK TO BE INCLUDED WITH THIS PERMIT. | | | | | | COMMENTS/QUESTIONS CONTACT ANDREINA DAVILA Q. OR | | | ANGELLA VANN, DEPUTY PLANNING DIRECTOR, AT (561) | | | 822-1435. | | | |
|
|