Plan Review Details - Permit 08070453
Plan Review Stops For Permit 08070453
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2008-08-26 Cont ID  
Sent By rmcdouga Date 2008-08-26 Time 13:42 Rev Time 0.00
Received By rmcdouga Date 2008-08-26 Time 13:42 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-07-29 Cont ID  
Sent By rmcdouga Date 2008-07-29 Time 10:21 Rev Time 0.00
Received By rmcdouga Date 2008-07-28 Time 16:40 Sent To  
Notes
2008-07-29 10:21:242004 FBC W/2007 REVISIONS
 ENCLOSED COVERED PORCH
  
 DENIED BY BUILDING
  
 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT WILL
 BE REQUIRED.
  
 2) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 3) THE STRUCTURE IS LOCATED IN AN AO FLOOD ZONE, AN
 ELEVATION CERTIFICATE WILL BE REQUIRED FOR THE ENCLOSED
 PORCH.
  
 4)SUBMIT TWO COPIES OF A SURVEY, SHOWING THE
 DISTANCES TO PROPERTY LINES AND SHOWING COMPLIANCE WITH
 R302.1 EXTERIOR WALLS.
 EXTERIOR WALLS SEPARATED BY LESS THAN 6 FEET (1828 MM)
 SHALL HAVE NOT LESS THAN A ONE-HOUR FIRE-RESISTIVE
 RATING WITH EXPOSURE FROM BOTH SIDES. PROJECTIONS SHALL
 NOT EXTEND TO A POINT CLOSER THAN 4 FEET (1220 MM) FROM
 AN ADJACENT PROJECTION OR WALL.
  
 5) SUBMIT TWO COPIES OF ENERGY CALCULATIONS FOR THE
 ENCLOSED PORCH. OWNER/AGENT IS REQUIRED TO SIGN THE
 FORM. SEE FBC 13-600.
  
 6) SPECIFY THE CEILING INSULATION ON THE PLANS. FBC
 13-600.
  
 7) THE BLOCK WALL LOAD CALCULATIONS STAPLED TO SHEET 3
 OF THE PLANS IS REQUIRED TO BE SIGNED AND SEALED. FS
 471 AND FBC 106.1* CITY AMENDMENTS.
  
 8) PLEASE PROVIDE THE WIND DESIGN DATA FOR THE ENCLOSED
 PORCH. BASIC WIND SPEED, WIND IMPORTANCE FACTOR, WIND
 EXPOSURE, ENCLOSURE CLASSIFICATION, EXPOSURE CATEGORY
 AND COMPONENT AND CLADDING PRESSURES (WINDOWS AND
 DOOR). FBC 1603.1.4 AND R301.
  
 9) SHOW COMPLIANCE WITH R403.1.4 MINIMUM DEPTH. ALL
 EXTERIOR FOOTINGS SHALL BE PLACED AT LEAST 12 INCHES
 (305 MM) BELOW THE UNDISTURBED GROUND SURFACE.
  
 10) SHOW COMPLIANCE WITH R806.1 VENTILATION REQUIRED.
 ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES FORMED WHERE
 CEILINGS ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF
 RAFTERS SHALL HAVE CROSS VENTILATION FOR EACH SEPARATE
 SPACE BY VENTILATING OPENINGS PROTECTED AGAINST THE
 ENTRANCE OF RAIN. VENTILATING OPENINGS SHALL BE
 PROVIDED WITH CORROSION-RESISTANT WIRE MESH, WITH 1/8
 INCH (3.2 MM) MINIMUM TO 1/4 INCH (6.4 MM) MAXIMUM
 OPENINGS.
  
 11) SPECIFY THE WINDOW TYPE ON THE PLANS, SO THAT THE
 CORRECT PRODUCT APPROVALS CAN BE VERIFIED. DCA RULE
 9B-72 AND FBC R301.2.1.
  
 12)FBC 106.3* CITY AMENDMENTS PRODUCT APPROVALS.
 THOSE PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72
 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL.
  
 13) THE PRODUCT APPROVALS THAT WERE SUBMITTED FOR THE
 WINDOWS ARE EXPIRED AND ARE FOR A XOX HORIZONTAL
 SLIDING WINDOW THAT ARE NOT SHOWN ON PLANS. SUBMIT A
 CURRENT PRODUCT APPROVAL FOR THE WINDOWS THAT WILL BE
 INSTALLED. RULE 9B-72
  
 14) THE PRODUCT APPROVALS THAT WERE SUBMITTED FOR THE
 DOORS ARE EXPIRED AND ARE FOR A SLIDING GLASS DOOR AND
 THE PLANS SPECIFY A DOUBLE OUTSWING FRENCH DOOR. SUBMIT
 A CURRENT PRODUCT APPROVAL FOR THE DOOR THAT WILL BE
 INSTALLED. RULE 9B-72
  
 15) THE DOOR PRODUCT APPROVAL THAT WAS SUBMITTED IS FOR
 A NON-IMPACT RATED DOOR. SUBMIT PRODUCT APPROVALS FOR
 STORM PANELS AS REQUIRED BY FBC R301.2.1.2. SPECIFY THE
 MOUNT TYPE, EDGE DISTANCE, GLASS SEPARATION DISTANCE,
 FASTENER TYPE AND SPACING, SPANS, ETC.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2008-07-25 Cont ID  
Sent By btrobaug Date 2008-07-25 Time 09:46 Rev Time 0.00
Received By btrobaug Date 2008-07-25 Time 09:40 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2008-08-14 Cont ID  
Sent By adarroug Date 2008-08-14 Time 14:09 Rev Time 0.00
Received By adarroug Date 2008-08-14 Time 14:09 Sent To Z
Notes
2008-08-14 14:10:03TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-07-29 Cont ID  
Sent By rmcdouga Date 2008-07-29 Time 10:21 Rev Time 0.00
Received By rmcdouga Date 2008-07-24 Time 09:18 Sent To  
Notes
2008-07-24 09:18:40TO "SFR" "E"

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-07-28 Cont ID  
Sent By rmcdouga Date 2008-07-28 Time 16:40 Rev Time 0.00
Received By rmcdouga Date 2008-07-28 Time 16:40 Sent To  
Notes
2008-07-16 11:09:40TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2008-07-24 Cont ID  
Sent By tgordon Date 2008-07-24 Time 16:20 Rev Time 0.25
Received By tgordon Date 2008-07-24 Time 16:20 Sent To E
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2008-07-25 Cont ID  
Sent By mperson Date 2008-07-25 Time 13:30 Rev Time 0.00
Received By mperson Date 2008-07-25 Time 13:30 Sent To B
Notes
2008-07-25 13:32:20NOTE: THERE IS NO PLUMBING ON THE PLANS AND THERE IS NO
 PLUMBING PERMIT APPLIED FOR ON THE PERMIT APPLICATION.
 **MRPERSON.

Review Stop Z ZONING
Rev No 2 Status P Date 2008-08-24 Cont ID  
Sent By mcruz Date 2008-08-24 Time 11:27 Rev Time 0.00
Received By mcruz Date 2008-08-24 Time 11:27 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2008-07-23 Cont ID  
Sent By mcruz Date 2008-07-23 Time 17:02 Rev Time 0.00
Received By mcruz Date 2008-07-23 Time 17:02 Sent To I
Notes
2008-07-23 17:05:34**ZONING FAILED**
  
 1.PLEASE PROVIDE ALL RESPONSES IN WRITING.
  
 2.PROVIDE TWO (2) COPIES OF A CURRENT SURVEY, WHICH
 INCLUDES THE PROPERTY?S ADDRESS AND LEGAL DESCRIPTION.
 MARK ON THE SURVEY THE LOCATION OF THE PROPOSED SCREEN
 ENCLOSURE, INCLUDING THE SETBACK DIMENSIONS TO EACH
 PROPERTY LINE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO
 CONTACT ME AT:(561) 822-1444 OR (561) 805-6720 OR
 [email protected]
  
 MAGGIE CRUZ, ASSOCIATE PLANNER
 PLANNING AND ZONING DEPARTMENT