| 2008-08-01 14:11:36 | BUILDING PLAN REVIEW |
| | PERMIT: 08070414 |
| | ADD: 3705 S. FLAGLER DR. #31 |
| | CONT: CRIBB CONSTRUCTION |
| | TEL: (561)689-6900 |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | W/ 2007 FBC REVISIONS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | 8-1-08 |
| | REVIEW: 1ST |
| | ACTION: DENIED |
| | |
| | 1)WHEN RESUBMITTING PLANS PLEASE INDICATE THE |
| | REVISION & REMOVE & REPLACE ANY PAGES AS NECESSARY. A |
| | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT |
| | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, |
| | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE |
| | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. |
| | THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | 2) FL S S 713.13NOTICE OF COMMENCEMENT, TO BE FILED |
| | WITH THE CLERK OF THE COURT. NOTE: 713.13(2) IF THE |
| | WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS NOT |
| | ACTUALLY COMMENCED WITHIN 90 DAYS AFTER THE RECORDING |
| | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) |
| | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE |
| | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. |
| | |
| | 3)THE DESCRIPTION ON THE APPLICATION DOES NOT MATCH |
| | THE INFORMATION ON THE DRAWINGS. PROVIDE THE PRODUCT |
| | APPROVALS FOR THE NEW DOOR AND WINDOW AS INDICATED ON |
| | THE PLANS. THE PRODUCT APPROVAL SHALL INDICATE WHICH |
| | DOOR OR WINDOW WILL BE USED AT THE PROJECT. 106.3.3* |
| | PRODUCT APPROVALS- 2004 THOSE PRODUCTS THAT ARE |
| | REGULATED BY DCA RULE 9B-72 SHALL BEREVIEWED AND |
| | APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO |
| | SUBMITTAL FOR JURISDICTIONAL APPROVAL. |
| | |
| | 4)1207.3 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING |
| | UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC OR |
| | SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN IMPACT |
| | INSULATION CLASS (IIC) RATING OF NOT LESS THAN 50 (45 |
| | IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E |
| | 492. PROVIDE THE MANUFACTURE SPECIFICATIONS FOR THE |
| | SOUND BARRIER FOR THE NEW FLOOR SYSTEM. |
| | |
| | 5)2004 FBC EXISTING 301.5 A DESIGN PROFESSIONAL OR AN |
| | OWNER MUST ELECT ONE OR A COMBINATION OF LEVELS OF |
| | ALTERATION PURSUANT TO SECTIONS 303, 304 AND 305 OF |
| | THIS CODE. |
| | |
| | 6)THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS |
| | LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS |
| | AND SYSTEMS SHALL BE TOTAL REPLACEMENT VALUE TO INCLUDE |
| | ELECTRIC, PLUMBING, INTERIOR FINISHES, ARCHITECTURAL |
| | AND DESIGN FEES, MARKETING COSTS, OVERHEAD AND PROFIT; |
| | EXCLUDING LAND. OUR VALUATION REFERENCE IS ICC (BVD), |
| | MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES PER |
| | 108.3 FBC* |
| | |
| | 7)SUBMIT A DETAIL DRAWING FOR THE NEW DRYWALL ON THE |
| | CEILING; INDICATE THE SCREW SPACING AND THE EXISTING |
| | STUDS SPACING. IF ADDITIONAL STUDS WILL BE ADDED |
| | INDICATE HOW THEY WILL BE ATTACHED TO THE ABOVE |
| | STRUCTURE. ADDITIONAL INFORMATION REQUIRED 106.1.2* |
| | |
| | NOTE: PLEASE INDICATE THE HEIGHT OF THE BUILDING ON THE |
| | PLANS. |
| | |
| | MYRON JACOBS |
| | BUILDING PLAN REVIEWER |
| | (561)805-6726 |
| | [email protected] |