Plan Review Details - Permit 08070414
Plan Review Stops For Permit 08070414
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2008-09-04 Cont ID  
Sent By mjacobs Date 2008-09-04 Time 15:06 Rev Time 0.00
Received By mjacobs Date 2008-09-04 Time 08:04 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-08-01 Cont ID  
Sent By mjacobs Date 2008-08-01 Time 14:11 Rev Time 0.00
Received By mjacobs Date 2008-08-01 Time 09:56 Sent To  
Notes
2008-08-01 14:11:36BUILDING PLAN REVIEW
 PERMIT: 08070414
 ADD: 3705 S. FLAGLER DR. #31
 CONT: CRIBB CONSTRUCTION
 TEL: (561)689-6900
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 8-1-08
 REVIEW: 1ST
 ACTION: DENIED
  
 1)WHEN RESUBMITTING PLANS PLEASE INDICATE THE
 REVISION & REMOVE & REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 2) FL S S 713.13NOTICE OF COMMENCEMENT, TO BE FILED
 WITH THE CLERK OF THE COURT. NOTE: 713.13(2) IF THE
 WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS NOT
 ACTUALLY COMMENCED WITHIN 90 DAYS AFTER THE RECORDING
 THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6)
 THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE
 CONSTRUCTION SITE BEFORE THE FIRST INSPECTION.
  
 3)THE DESCRIPTION ON THE APPLICATION DOES NOT MATCH
 THE INFORMATION ON THE DRAWINGS. PROVIDE THE PRODUCT
 APPROVALS FOR THE NEW DOOR AND WINDOW AS INDICATED ON
 THE PLANS. THE PRODUCT APPROVAL SHALL INDICATE WHICH
 DOOR OR WINDOW WILL BE USED AT THE PROJECT. 106.3.3*
 PRODUCT APPROVALS- 2004 THOSE PRODUCTS THAT ARE
 REGULATED BY DCA RULE 9B-72 SHALL BEREVIEWED AND
 APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO
 SUBMITTAL FOR JURISDICTIONAL APPROVAL.
  
 4)1207.3 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING
 UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC OR
 SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN IMPACT
 INSULATION CLASS (IIC) RATING OF NOT LESS THAN 50 (45
 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E
 492. PROVIDE THE MANUFACTURE SPECIFICATIONS FOR THE
 SOUND BARRIER FOR THE NEW FLOOR SYSTEM.
  
 5)2004 FBC EXISTING 301.5 A DESIGN PROFESSIONAL OR AN
 OWNER MUST ELECT ONE OR A COMBINATION OF LEVELS OF
 ALTERATION PURSUANT TO SECTIONS 303, 304 AND 305 OF
 THIS CODE.
  
 6)THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS
 LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS
 AND SYSTEMS SHALL BE TOTAL REPLACEMENT VALUE TO INCLUDE
 ELECTRIC, PLUMBING, INTERIOR FINISHES, ARCHITECTURAL
 AND DESIGN FEES, MARKETING COSTS, OVERHEAD AND PROFIT;
 EXCLUDING LAND. OUR VALUATION REFERENCE IS ICC (BVD),
 MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES PER
 108.3 FBC*
  
 7)SUBMIT A DETAIL DRAWING FOR THE NEW DRYWALL ON THE
 CEILING; INDICATE THE SCREW SPACING AND THE EXISTING
 STUDS SPACING. IF ADDITIONAL STUDS WILL BE ADDED
 INDICATE HOW THEY WILL BE ATTACHED TO THE ABOVE
 STRUCTURE. ADDITIONAL INFORMATION REQUIRED 106.1.2*
  
 NOTE: PLEASE INDICATE THE HEIGHT OF THE BUILDING ON THE
 PLANS.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 (561)805-6726
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2008-08-27 Cont ID  
Sent By btrobaug Date 2008-08-27 Time 16:21 Rev Time 0.00
Received By btrobaug Date 2008-08-27 Time 16:21 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2008-08-04 Cont ID  
Sent By btrobaug Date 2008-08-04 Time 11:10 Rev Time 0.00
Received By btrobaug Date 2008-08-04 Time 11:10 Sent To I
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2008-08-29 Cont ID  
Sent By mwennerg Date 2008-08-29 Time 10:22 Rev Time 0.00
Received By mwennerg Date 2008-08-29 Time 10:22 Sent To  
Notes
2008-08-29 10:23:27STAMPED NEW SHEET A-1. (2)

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2008-08-01 Cont ID  
Sent By mwennerg Date 2008-08-01 Time 14:55 Rev Time 0.00
Received By mwennerg Date 2008-08-01 Time 14:55 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-08-21 Cont ID  
Sent By adarroug Date 2008-08-21 Time 12:03 Rev Time 0.00
Received By adarroug Date 2008-08-21 Time 12:03 Sent To  
Notes
2008-08-25 08:47:37TO BOB #5.
2008-08-21 12:04:08WAITING FOR "BOB"

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-08-04 Cont ID  
Sent By btrobaug Date 2008-08-04 Time 11:11 Rev Time 0.00
Received By btrobaug Date 2008-07-15 Time 15:41 Sent To PC
Notes
2008-07-15 15:43:52TO "BOB"#15

Review Stop P PLUMBING
Rev No 2 Status P Date 2008-08-25 Cont ID  
Sent By mperson Date 2008-08-25 Time 16:29 Rev Time 0.00
Received By mperson Date 2008-08-25 Time 16:29 Sent To  
Notes
2008-08-25 16:30:14NOTE: EXACT FIXTURE CHANGE OUT. *MRPERSON.

Review Stop P PLUMBING
Rev No 1 Status P Date 2008-08-05 Cont ID  
Sent By mperson Date 2008-08-05 Time 11:35 Rev Time 0.00
Received By mperson Date 2008-08-05 Time 11:35 Sent To PC
Notes
2008-08-05 11:36:54NOTE: EXACT FIXTURE CHANGE OUT. *MRPERSON.

Review Stop Z ZONING
Rev No 1 Status N Date 2008-07-17 Cont ID  
Sent By eschneid Date 2008-07-17 Time 10:13 Rev Time 0.00
Received By eschneid Date 2008-07-17 Time 10:12 Sent To  
Notes
***NONE***