Plan Review Details - Permit 08070320
| Plan Review Stops For Permit 08070320 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
15 |
Status |
P |
Date |
2009-08-21 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2009-08-21 |
Time |
11:05 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2009-08-21 |
Time |
11:05 |
Sent To |
|
|
| Notes |
| 2009-08-21 11:06:57 | SUBMITTAL ON 7/09/09 FOR STRUCTURAL INTEGRITY OF | | | PACKAGE UNITS SUBJECT TO WIND LOADS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
14 |
Status |
F |
Date |
2009-06-25 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2009-06-25 |
Time |
19:52 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2009-06-25 |
Time |
19:52 |
Sent To |
|
|
| Notes |
| 2009-06-25 20:16:41 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN (561) 805 6652 | | | E-MAIL: [email protected] | | | | | | FBC = FLORIDA BUILDING CODE 2004 | | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | F.S.= FLORIDA (STATE) STATUTE | | | | | | SUBMITTAL ON 6/22/09 FOR STRUCTURAL WIND LOAD INTEGRITY | | | OF PACKAGE UNITS. | | | | | | 1) FBCM 301.13 MECHANICAL UNITS EXPOSED TO WIND. FOR | | | THE SANYO OUTDOOR UNITS THE FIFTH PAGE (UNNUMBERED) OF | | | THE CALCULATION REPORT ONLY ADDRESSES AND SPECIFIES THE | | | SCREWS REQUIRED FOR ATTACHMENT OF THE UNIT TO IT'S | | | "BOTTOM PLATE ASSEMBLY". THE REPORT GOES ON TO SHOW | | | EXPLODED VIEWS OF THE UNIT CONSTRUCTION BUT THE | | | CALCULATIONS DO NOT ADDRESS THE REQUIREMENT TO SHOW | | | THAT THE EXTERNAL (VERTICAL AND HORIZONTAL) PANELS OF | | | THE UNIT WILL RETAIN THEIR INTEGRITY AND REMAIN | | | ATTACHED TO THE UNIT WHEN SUBJECT TO THE WIND PRESSURES | | | RESULTING FROM 140 MPH WIND SPEED (3 SECOND GUST). | | | THERE ARE NO CALCULATIONS FOR THE SCREWS/FASTENERS | | | HOLDING THE PANELS TOGETHER, AND THERE ARE NO | | | CALCULATIONS FOR THE PANELS THEMSELVES (SHEAR AT HOLES | | | BASED ON HOLE SIZE AND EDGE DISTANCE , ETC.). AS SUCH | | | THE SUBMITTED CALCULATIONS DO NOT ADDRESS THE 12/17/08 | | | PROVISO GIVEN BY RON REGUEIRO, MECHANICAL PLANS | | | EXAMINER II. THE MECHANICAL CODE SECTION REQUIRES THAT | | | THE APPLIANCE ITSELF BE DESIGNED AND INSTALLED TO | | | RESIST THE WIND PRESSURES. SUBMIT MANUFACTURER'S TEST | | | DATA OR STRUCTURAL CALCULATIONS TO SHOW THAT THE | | | PACKAGE UNIT HAS BEEN TESTED OR DESIGNED FOR THE WIND | | | PRESSURES RESULTING FROM 140 MPH WIND SPEED (3 SECOND | | | GUST). THE PROVISO GIVEN BY THE MECHANICAL PLANS | | | EXAMINER ON 12/17/08 STATED THIS SAME REQUIREMENT, | | | QUOTE: "PROVIDE MANUFACTURER'S SUBMITTAL DATA SHOWING | | | OUTDOOR APPLIANCES ARE DESIGNED TO RESIST WIND | | | PRESSURES IN ACCORDANCE WITH FBCM 301.13." | | | | | | 2) 471.025 F.S. AND 61G15-23.002 FL. ADMINISTRATIVE | | | CODE. ONLY THE COVER PAGE OF BOTH CALCULATION REPORTS | | | IS SIGNED AND SEALED. WHEN SUBMITTING CALCULATION | | | REPORTS THE ENGINEER MUST EITHER SIGN AND SEAL EACH | | | SHEET OR PROVIDE A SIGNED AND SEALED CONTENTS PAGE | | | WHICH REFERENCES THE SHEET NUMBER OF EACH SHEET IN THE | | | CALCULATION REPORT. | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | | TELEPHONE: (561) 805 6652 ROBERT BROWN | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
13 |
Status |
P |
Date |
2009-06-19 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2009-06-19 |
Time |
11:43 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2009-06-19 |
Time |
11:43 |
Sent To |
|
|
| Notes |
| 2009-06-19 11:44:18 | CAVITY SHAFT WALL SUBMITTAL | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
12 |
Status |
P |
Date |
2009-06-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2009-06-10 |
Time |
13:05 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2009-06-10 |
Time |
13:05 |
Sent To |
|
|
| Notes |
| 2009-06-10 13:06:13 | REVISION A001CR2 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
11 |
Status |
P |
Date |
2009-05-14 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2009-05-14 |
Time |
20:34 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2009-05-14 |
Time |
20:34 |
Sent To |
|
|
| Notes |
| 2009-05-14 20:35:42 | SUBMITTAL ON 4/27/09 FOR FIRESTOPPING RATED ASSEMBLIES. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
10 |
Status |
F |
Date |
2009-05-14 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2009-05-14 |
Time |
19:53 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2009-05-14 |
Time |
19:53 |
Sent To |
|
|
| Notes |
| 2009-05-14 20:09:33 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN (561) 805 6652 | | | E-MAIL: [email protected] | | | | | | FBC = FLORIDA BUILDING CODE 2004 | | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | F.S.= FLORIDA (STATE) STATUTE | | | | | | SUBMITTAL ON 4/27/09 FOR TIE DOWN CABLES ON PACKAGE | | | UNIT. | | | | | | 1) FBCM 301.13 MECHANICAL UNITS EXPOSED TO WIND. ONLY | | | TIE DOWN CABLES ARE BEING PROPOSED. THAT DOES NOT | | | ADDRESS THE 12/17/08 PROVISO GIVEN BY RON REGUEIRO, | | | MECHANICAL PLANS EXAMINER II. THE MECHANICAL CODE | | | SECTION REQUIRES THAT THE APPLIANCE ITSELF BE DESIGNED | | | AND INSTALLED TO RESIST THE WIND PRESSURES. SUBMIT | | | MANUFACTURER'S TEST DATA OR STRUCTURAL CALCULATIONS TO | | | SHOW THAT THE PACKAGE UNIT HAS BEEN TESTED OR DESIGNED | | | FOR THE WIND PRESSURES RESULTING FROM 140 MPH WIND | | | SPEED (3 SECOND GUST). THE PROVISO GIVEN BY THE | | | MECHANICAL PLANS EXAMINER ON 12/17/08 STATED THIS SAME | | | REQUIREMENT, QUOTE: "PROVIDE MANUFACTURER'S SUBMITTAL | | | DATA SHOWING OUTDOOR APPLIANCES ARE DESIGNED TO RESIST | | | WIND PRESSURES IN ACCORDANCE WITH FBCM 301.13." | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | | TELEPHONE: (561) 805 6652 ROBERT BROWN | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
9 |
Status |
P |
Date |
2009-04-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2009-04-02 |
Time |
18:03 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2009-04-02 |
Time |
18:03 |
Sent To |
|
|
| Notes |
| 2009-04-02 18:04:36 | REVISION | | | A101CR5, A103CR4,106CR3, A118CR5, A119CR5, A120CR5, | | | A901CR5 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
P |
Date |
2009-04-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2009-04-02 |
Time |
09:01 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2009-04-02 |
Time |
09:01 |
Sent To |
|
|
| Notes |
| 2009-04-02 09:19:17 | REVISION, CHANGE ROOF SYSTEM (STANDING SEAM) ON SOME | | | PORTIONS OF PROJECT | | | | | | SUBMITTALS; ROOF SHOPS AND LIGHT POLE CALCULATIONS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
F |
Date |
2009-03-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2009-03-30 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2009-03-30 |
Time |
10:50 |
Sent To |
|
|
| Notes |
| 2009-03-30 10:52:09 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2004 | | | FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FS FLORIDA STA | | | | | | 1. PLEASE HAVE ALL SUBMITTALS/SHOP DRAWINGS REVIEWED BY | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL. FAC61G15-23, | | | FAC61G1. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2009-03-09 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2009-03-09 |
Time |
18:35 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2009-03-09 |
Time |
18:35 |
Sent To |
|
|
| Notes |
| 2009-03-09 18:40:21 | REVISION ADDRESSING BUILDING AND ELECTRIC | | | PROVISOS/REDLINES: | | | | | | A101CR4, A118CR4, A120CR4, A123CR1, A901CR4 | | | | | | SUBJECT TO FIRE & ELECTRIC REVIEWS | | | | | | RECEIVED SHOP DRAWING REVIEW LETTER FROM DOR (PROVISO | | | ITEM), 1 LETTER FILED, 1 STAMPED & RETURNED TO CONTR | | | WITH CALCS (STAMPED PREVIOUS REVIEW) | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2009-02-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2009-02-25 |
Time |
17:12 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2009-02-25 |
Time |
17:12 |
Sent To |
|
|
| Notes |
| 2009-02-25 17:17:47 | REVISION DATED 2/6/9 SHEETS A101CR3, A103CR3, A106CR2, | | | A110CR2, A113CR3, A118CR3, A119CR3, A120CR3, A901CR3 | | | | | | **PROVISO** | | | ALL SUBMITTALS & DELEGATED ENGINEERING TO BE REVIEWED | | | BY DOR; SUBMIT LETTER | | | ** ISSUED AT CONTRACTOR???S RISK | | | PLAN REDLINED; 1 HR CORRIDOR REQUIRED AT EGRESS STAIR | | | SUBMIT REVISION (CHANGE WALL DESIGNATION AT THIS AREA | | | TO REFLECT | | | CONSTRUCTION OF 1 HR WALLS, PER ARCHITECT) | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2008-12-08 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-12-08 |
Time |
16:00 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-12-08 |
Time |
16:00 |
Sent To |
|
|
| Notes |
| 2008-12-08 16:01:08 | **PROVISO** - REVISE AS FOLLOWS, PRIOR TO INSTALLATION | | | | | | WBCM SUBMITTAL #8, CALCULATIONS CM MANUFACTURING, | | | PLEASE ADDRESS: | | | | | | A. ASCE7-05 REFERENCED; FBC2004 REQUIRES ASCE7-02. THIS | | | CAN BE DONE WITH A LETTER OR CAN BE A PROVISO ITEM. | | | | | | B. SEE PAGE 22, EXPOSURE B USED WITH AN IMPORTANCE | | | FACTOR OF .77. IF ACCEPTABLE TO THE DESIGNER OF RECORD, | | | THE REDUCED IMPORTANCE FACTOR CAN BE USED BUT PROVIDE | | | JUSTIFICATION FOR USE OF EXPOSURE B. THIS JOB APPEARS | | | TO HAVE EXPOSURE C CONDITIONS, FBC1609.4. | | | | | | C. CALCS AND PLANS DO NOT NEED TO BE REVISED, BUT | | | PLEASE NOTE THAT GOVERNING CODE IS FBC2004 WITH 2007 | | | REVISIONS/SUPPLEMENTS. CALCS REFER TO 2005 AND 2006 | | | REVISIONS AND SUPPLEMENTS, PLANS STATE COMPLIANCE WITH | | | INTERNATIONAL BUILDING CODE 2003. FOR FUTURE | | | SUBMITTALS, PLEASE REVISE. | | | | | | D. PAGE 21 NOTE STATES "LATERAL IMPACT DOES NOT ALLOW | | | 1/3 STRESS INCREASE AS ALLOWED FOR ASD WIND LOAD | | | ANALYSIS" PLEASE PROVIDE MORE INFORMATION REGARDING | | | STRESS INCREASE USED AND SEE FBC1605.3.1.1 AND CLARIFY | | | USE OF STRESS INCREASE. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2008-11-21 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-11-21 |
Time |
11:33 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-11-20 |
Time |
07:58 |
Sent To |
|
|
| Notes |
| 2008-11-21 11:40:45 | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2004 | | | FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FS FLORIDA STATUTE | | | | | | 1-79. ADDRESSED. | | | | | | 80. PLEASE SHOW COMPLIANCE WITH FBC910, SMOKE AND HEAT | | | VENTS. PROVIDE CALCULATIONS ON THE PLAN AND SHOW | | | COMPLIANCE WITH ALL REQUIREMENTS. | | | | | | THE REQUEST FOR CONSIDERATION UNDER ALTERNATE MATERIALS | | | AND METHODS HAS BEEN FORWARDED TO ROBERT BROWN FOR | | | REVIEW. THIS REVIEW WILL REMAIN IN FAILED STATUS UNTIL | | | HIS DECISION. IF THIS REQUEST IS DENIED, THIS REVIEW | | | WILL BE PASSED WITH PROVISO TO REVISE DESIGN TO INCLUDE | | | THE REQUIRED SMOKE AND HEAT VENTS. IF APPROVED, A | | | PASSED STATUS WILL BE ENTERED FOR THIS REVIEW. | | | | | | 81-87. ADDRESSED. | | | | | | 88. **PROVISO** - REVISE AS FOLLOWS, PRIOR TO | | | INSTALLATION | | | | | | WBCM SUBMITTAL #8, CALCULATIONS CM MANUFACTURING, | | | PLEASE ADDRESS: | | | | | | A. ASCE7-05 REFERENCED; FBC2004 REQUIRES ASCE7-02. THIS | | | CAN BE DONE WITH A LETTER OR CAN BE A PROVISO ITEM. | | | | | | B. SEE PAGE 22, EXPOSURE B USED WITH AN IMPORTANCE | | | FACTOR OF .77. IF ACCEPTABLE TO THE DESIGNER OF RECORD, | | | THE REDUCED IMPORTANCE FACTOR CAN BE USED BUT PROVIDE | | | JUSTIFICATION FOR USE OF EXPOSURE B. THIS JOB APPEARS | | | TO HAVE EXPOSURE C CONDITIONS, FBC1609.4. | | | | | | C. CALCS AND PLANS DO NOT NEED TO BE REVISED, BUT | | | PLEASE NOTE THAT GOVERNING CODE IS FBC2004 WITH 2007 | | | REVISIONS/SUPPLEMENTS. CALCS REFER TO 2005 AND 2006 | | | REVISIONS AND SUPPLEMENTS, PLANS STATE COMPLIANCE WITH | | | INTERNATIONAL BUILDING CODE 2003. FOR FUTURE | | | SUBMITTALS, PLEASE REVISE. | | | | | | D. PAGE 21 NOTE STATES "LATERAL IMPACT DOES NOT ALLOW | | | 1/3 STRESS INCREASE AS ALLOWED FOR ASD WIND LOAD | | | ANALYSIS" PLEASE PROVIDE MORE INFORMATION REGARDING | | | STRESS INCREASE USED AND SEE FBC1605.3.1.1 AND CLARIFY | | | USE OF STRESS INCREASE. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2008-11-06 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-11-06 |
Time |
12:22 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-10-29 |
Time |
10:56 |
Sent To |
|
|
| Notes |
| 2008-11-06 12:22:30 | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2004 | | | FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FS FLORIDA STATUTE | | | | | | 1-29. ADDRESSED. | | | | | | 30. ADDRESSED. | | | | | | 31C. PAGE 4 OF THE CALCULATIONS, OTHER SHEETS, PLANS, | | | REFER TO 2004 FLORIDA STATE BUILDING CODE; PLEASE | | | REVISE TO GOVERNING CODE WHICH IS FLORIDA BUILDING CODE | | | 2004 WITH 2007 REVISIONS/SUPPLEMENTS. | | | | | | 2ND REVIEW, PLANS AND CALCS STILL STATE 2004 FLORIDA | | | STATE BUILDING CODE; THIS SHOULD STATE FLORIDA BUILDING | | | CODE OR FBC 2004 (WITH 2007 REVISIONS/SUPPLEMENTS). | | | | | | E. ALL SIGNED AND SEALED SHEETS ARE TO INCLUDE ALL | | | INFORMATION REQUIRED BY FAC61G15-23.002. | | | | | | 2ND REVIEW, A NUMBER WAS INCLUDED BUT THIS NUMBER WAS | | | ISSUED TO VP CONSOLIDATED HOLDINGS, INC. THE COMPANY ON | | | THE PLANS IS VP BUILDINGS, INC. I WAS UNABLE TO FIND A | | | DBA, AND HAVE CONTACTED FBPE TO DETERMINE WHETHER OR | | | NOT THIS IS ACCEPTABLE. ALSO, VP CONSOLIDATED HOLDINGS, | | | INC. HAVE FILED A WITHDRAWAL STATING THAT THEY WILL NO | | | LONGER DO BUSINESS IN FLORIDA. HAS ADDITIONAL PAPERWORK | | | BEEN FILED WHICH I AM UNABLE TO LOCATE ON THE INTERNET? | | | COMPLIANCE WITH FS471.023(1) IS NOT CLEAR. | | | HTTP://WWW.SUNBIZ.ORG/PDF/15259987.PDF | | | | | | 32?39. ADDRESSED. | | | | | | 40. (INFORMATIONAL) THE 3 RING BINDER ENTITLED | | | TECHNICAL SPECIFICATIONS WILL BE INCLUDED WITH THE | | | RECORD SET WITH THE PROVISO IN ACCORDANCE WITH FBC2004 | | | AND PLAN. NO ACTION REQUIRED. | | | | | | 41-43. ADDRESSED. | | | | | | 44. SEE FBC TABLE 1016.1, CORRIDORS 203 AND 205 FROM | | | VISITOR'S GALLERY TO STAIRS TO HAVE 1 HOUR FIRE | | | RESISTIVE RATING AND THEREFORE DOORS 203 1, 204 1, 205 | | | 1, 206 1, 200 1, TO BE RATED IN ACCORDANCE WITH | | | FBC715.3. | | | | | | 2ND REVIEW, AS DISCUSSED WITH ENGINEER, THIS ITEM WILL | | | BE ADDRESSED IN RESUBMITTAL. NOTE THAT SOME DOORS FROM | | | FIRST REVIEW WERE REMOVED, SO THERE IS ONLY ONE | | | CORRIDOR FROM MEZZANINE LEVEL. AS DISCUSSED, THE | | | CORRIDOR STARTS AT THE DOOR (MEANS OF EGRESS STAIR | | | HALLWAY TO VIEWING GALLERY) AND TERMINATES AT THE EXIT, | | | GROUND FLOOR (CORRIDOR MUST TERMINATE AT AN EXIT, WHICH | | | IN THIS CASE IS THE EXIT DISCHARGE), SO ALTHOUGH THIS | | | IS NOT A RATED EXIT STAIR, THE STAIR IS CONTAINED IN A | | | 1 HOUR CORRIDOR. PLEASE CONTACT ME IF YOU WISH TO | | | DISCUSS. | | | | | | 45-54. ADDRESSED. | | | | | | 55. FBC13-101.1, ENERGY CALCS REQUIRED FOR BOTH THE | | | MAIN BUILDING AND FOR THE SCALE HOUSE. | | | | | | 2ND REVIEW, ENERGY CALCS SUBMITTED. FOR THE MAIN | | | BUILDING, 2 DOORS ARE SHOWN. ISN'T THE WALL BETWEEN THE | | | ADMIN AREA AND PROCESSING TO BE TREATED AS A WALL, | | | INCLUDED IN THE INPUT DATA REPORT, AND THE DOORS NOTED? | | | I WAS UNABLE TO LOCATE MEZZANINE WINDOWS IN THE INPUT | | | DATA REPORT. THE SLAB IS NOTED AS 6.38 R VALUE; PLEASE | | | CLARIFY. THE ROOF ON THE ENERGY CALC IS SHOWN AS 32.8 R | | | VALUE, PLAN (SEE DETAIL 9 A110CR1) SPECIFIES R19 BATT. | | | IF THE PEMB ROOF INCLUDES INSULATION, PLEASE PROVIDE | | | THIS INFORMATION ON THE PLAN. NOTE THAT THE TYPED NAME | | | AND LICENSE NUMBER OF THE ARCHITECT FOR CERTIFICATION | | | BY THE ARCHITECT IS ACCEPTABLE ON THE ENERGY CALC IN | | | LIEU OF SIGNATURE IF ALL INFORMATION IS INCLUDED ON THE | | | PLAN FBC13-103.1.1.1. PLEASE CONFIRM INPUT DATA | | | REQUIREMENTS AND REVISE AS NECESSARY. THIS LIST IS NOT | | | BE COMPREHENSIVE; PLEASE CHECK ALL. | | | | | | 56-58. ADDRESSED. | | | | | | 59. SEE FBC1016.4, AIR MOVEMENT IN CORRIDORS. PLEASE | | | REMOVE SUPPLY, RETURN, EXHAUST, RELIEF OR VENTILATION | | | AIR DUCTS FROM EXIT ACCESS CORRIDORS, SEE OTHER | | | COMMENTS. PLEASE NOTE THAT THERE ARE TWO HALLS IN THE | | | MEZZANINE WHICH SERVE AS CORRIDORS. | | | | | | 2ND REVIEW, ONE DOOR WAS REMOVED, SO ONLY ONE CORRIDOR | | | SERVING THE MEZZANINE REMAINS. PLEASE REVISE PLANS IN | | | ACCORDANCE WITH FBC1016.4, SEE ALSO OTHER COMMENTS | | | REGARDING 1 HOUR FIRE RATING REQUIRED. | | | | | | 60-61. ADDRESSED. | | | | | | 62. A114C, SPECIFY GUARD PICKET SPACING FBC1012. | | | | | | A114 WAS REVISED TO SPECIFY 4IN, BUT THIS IS TO RESIST | | | A 4IN OBJECT (REQUIRES SPACING LESS THAN 4IN). THIS CAN | | | BE A REDLINE ITEM IF REQUESTED. | | | | | | 63. ADDRESSED. | | | | | | 64. SEE 3 A007C, THE HANDRAIL IS NOT CONTINUOUS. A106C | | | HANDRAIL EXTENSIONS AT BOTTOM IS NOT SHOWN. PLEASE | | | PROVIDE DETAILS AND CORRELATE A SHEETS. | | | | | | 2ND REVIEW, THE ELEVATION ON A106C DOES NOT SHOW THE | | | EXTENSION REQUIRED, FBC11-4.9.4(2). AT THE BOTTOM, THE | | | HANDRAIL SHALL CONTINUE TO SLOPE FOR THE DISTANCE OF | | | WIDTH OF ONE TREAD FROM THE BOTTOM RISER, THE REMAINDER | | | OF THE EXTENSION WILL BE HORIZONTAL, FBC FIGURE 19(D). | | | SEE ALSO DETAIL 1 113, A A007 (BOTTOM). THE EXTENSIONS | | | ARE SHOWN CORRECTLY IN OTHER DETAILS. PLEASE CHECK ALL. | | | | | | 65-72. ADDRESSED. | | | | | | 73. SHOW LOCATION OF STROBES, FBC11-4.28.1. | | | | | | 2ND REVIEW, PLEASE ADD TO BATHROOM 108, TRUCKER?S | | | BATHROOM. PLEASE CONFIRM THAT STROBES ARE SHOWN IN ALL | | | LOCATIONS REQUIRED. | | | | | | 74-76. ADDRESSED. | | | | | | 77. PROVIDE A SPECIFICATION FOR ATTACHMENT OF THE | | | BACKING FOR THE GRAB BARS (A111C) TO SHOW COMPLIANCE | | | WITH FBC1607.7.1.1, FBC11-4.26.3. DETAIL STATES SCREWED | | | TO STUD BUT DOES NOT SPECIFY SIZE OF SCREWS OR DISTANCE | | | APART, DOES NOT SPECIFY A WIDTH FOR THE 22G SHEET METAL | | | BACKING. | | | | | | 2ND REVIEW, SPECIFICATION NOT PROVIDED. THIS CAN BE A | | | PROVISO ITEM; PROVIDE SHOPS BEFORE INSTALLATION. THIS | | | WILL BE REDLINED TO INCLUDE CONCENTRATED LOAD | | | REQUIREMENT OF 250 PLF 1607.7.2. | | | | | | 78-79. ADDRESSED. | | | | | | 80. PLEASE SHOW COMPLIANCE WITH FBC910, SMOKE AND HEAT | | | VENTS. PROVIDE CALCULATIONS ON THE PLAN AND SHOW | | | COMPLIANCE WITH ALL REQUIREMENTS. | | | | | | THE REQUEST FOR CONSIDERATION UNDER ALTERNATE MATERIALS | | | AND METHODS HAS BEEN FORWARDED TO ROBERT BROWN FOR | | | REVIEW. | | | | | | 81-85. ADDRESSED. | | | | | | NEW COMMENTS (NEW SUBMITTALS) ? PLEASE NOTE THAT | | | SUBMITTALS ARE NOT REQUIRED AT THIS TIME; THEY CAN BE | | | SUBMITTED PRIOR TO INSTALLATION: | | | | | | 86. **THIS SUBMITTAL CAN BE A PROVISO ITEM (SUBMIT | | | BEFORE INSTALLATION)** | | | ASSOCIATED ENGINEERING INCORPORATED IS TO HAVE A | | | CERTIFICATE OF AUTHORIZATION, FS471 (WBCM SUBMITTAL | | | #7). "AUTH # PENDING" WAS WRITTEN ON THE SHEETS | | | PREPARED BY RONALD T. FOSS, P.E. FOR THE SORT | | | ENCLOSURES, BUT THIS COMPANY NAME CANNOT BE USED UNTIL | | | THE NUMBER IS ISSUED. THE WEBSITE DOES NOT INDICATE | | | THAT AN APPLICATION IS PENDING. ARE THESE SHEETS | | | REQUIRED AT THIS TIME? CAN THEY BE SUBMITTED AFTER A | | | COFA HAS BEEN OBTAINED? A SET HAS BEEN RETAINED. PLEASE | | | INFORM MR. FOSS OF THE REQUIREMENT TO OBTAIN THIS | | | CERTIFICATE AND PLEASE HAVE HIM SEND AN EMAIL | | | CONFIRMING HIS UNDERSTANDING. | | | | | | 87. **THIS SUBMITTAL CAN BE A PROVISO ITEM (SUBMIT | | | BEFORE INSTALLATION)** | | | THE STRUCTURAL CALCULATIONS EQUIPMENT TIE-DOWN AND | | | CONNECTIONS TO ROOF STRUCTURE (WBCM SUBMITTAL #12) DOES | | | NOT INCLUDE A TITLE BLOCK, FAC61G15-23.002. | | | | | | 88. **THIS SUBMITTAL CAN BE A PROVISO ITEM (SUBMIT | | | BEFORE INSTALLATION)** | | | WBCM SUBMITTAL #8, CALCULATIONS, PLEASE ADDRESS: | | | | | | A. ASCE7-05 REFERENCED; FBC2004 REQUIRES ASCE7-02. THIS | | | CAN BE DONE WITH A LETTER OR CAN BE A PROVISO ITEM. | | | | | | B. SEE PAGE 22, EXPOSURE B USED WITH AN IMPORTANCE | | | FACTOR OF .77. IF ACCEPTABLE TO THE DESIGNER OF RECORD, | | | THE REDUCED IMPORTANCE FACTOR CAN BE USED BUT PROVIDE | | | JUSTIFICATION FOR USE OF EXPOSURE B. THIS JOB APPEARS | | | TO HAVE EXPOSURE C CONDITIONS, FBC1609.4. | | | | | | C. CALCS AND PLANS DO NOT NEED TO BE REVISED, BUT | | | PLEASE NOTE THAT GOVERNING CODE IS FBC2004 WITH 2007 | | | REVISIONS/SUPPLEMENTS. CALCS REFER TO 2005 AND 2006 | | | REVISIONS AND SUPPLEMENTS, PLANS STATE COMPLIANCE WITH | | | INTERNATIONAL BUILDING CODE 2003. FOR FUTURE | | | SUBMITTALS, PLEASE REVISE. | | | | | | D. PAGE 21 NOTE STATES "LATERAL IMPACT DOES NOT ALLOW | | | 1/3 STRESS INCREASE AS ALLOWED FOR ASD WIND LOAD | | | ANALYSIS" PLEASE PROVIDE MORE INFORMATION REGARDING | | | STRESS INCREASE USED AND SEE FBC1605.3.1.1 AND CLARIFY | | | USE OF STRESS INCREASE. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-08-08 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-08-08 |
Time |
15:08 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-08-08 |
Time |
15:08 |
Sent To |
|
|
| Notes |
| 2008-08-08 15:09:20 | ****PRIVATE PROVIDER AUDIT**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 FAC | | | FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | 1. THE OWNER'S ACKNOWLEDGEMENT IS REQUIRED, | | | FS553.791(4)(C). | | | | | | 2.THE PRIVATE PROVIDER AFFIDAVIT IS TO IDENTIFY THE | | | PLANS REVIEWED.THERE WAS A LOG PROVIDED, BUT THIS LOG | | | IS NOT A PART OF THE AFFIDAVIT.THE AFFIDAVIT STATES | | | "77 PAGES - ATTACHED" BUT NOTHING WAS ATTACHED; THE LOG | | | WAS SUBMITTED SEPARATELY.THE LOG DOES NOT PROPERLY | | | IDENTIFY EACH SHEET (SOME SHEETS HAVE DIFFERENT PAGE, | | | FOR INSTANCE E106CR1, M104C, M014C) AND THE LOG DOES | | | NOT IDENTIFY THE PLAN SHEETS BY DATE.NOT ALL SHEETS | | | WERE STAMPED BY GFA (E106CR1, S101CR1).IT APPEARS | | | THAT THE FIRE PROTECTION PLANS WERE NOT REVIEWED, OR | | | THE C SHEETS (WHICH SHOW COMPLIANCE WITH FBC11 AND FBC5 | | | REQUIREMENTS), BUT THIS IS REQUIRED BY | | | FBC*106.3.5.1.1(5), FS553.79 (2).NOTE THAT THE | | | FOUNDATION PERMIT HAS NOT YET BEEN ISSUED, SO CANNOT BE | | | USED TO SHOW CODE COMPLIANCE FOR THIS PLAN. | | | | | | 3. FIRE SPRINKLER PLANS REQUIRED.AT A MINIMUM, A HEAD | | | LAYOUT IS TO BE SUBMITTED, SEE FBC*106.3.5.1.1(5), | | | FS553.79(2), LETTER FROM DCA (AVAILABLE UPON REQUEST). | | | | | | 4. M SHEETS, THE SEAL IS TO INCLUDE THE DATE, | | | FAC61G15-23.002, FS471. | | | | | | 5. PLEASE NOTE THAT AN INDEX SHEET IS USEFUL WITH A | | | PLAN OF THIS SIZE.THIS IS NOT A REQUIREMENT, BUT A | | | SUGGESTION TO ASSIST WITH PLAN REVIEW.PROVIDING AN | | | INDEX SHEET WILL ENABLE PLAN REVIEWERS TO OBTAIN | | | NECESSARY INFORMATION MORE QUICKLY, WHICH WILL HELP TO | | | EXPEDITE THE PLAN REVIEW PROCESS AND CUT DOWN ON PLAN | | | REVIEW TIME. | | | | | | 6. TWO 8 1/2 X 11 SHEETS WERE SUBMITTED.NEITHER ARE | | | SEALED, ONE HAS THE DESIGNER'S TITLE BLOCK BUT IS | | | LACKING SOME OF THE INFORMATION REQUIRED BY | | | FAC61G15-23.002; THE OTHER IS NOT SEALED.PLEASE | | | INCORPORATE THESE CHANGES INTO THE SIGNED AND SEALED | | | PLAN. | | | | | | 7. N/A. | | | | | | 8. FBC* 109.3.7RESIDENT INSPECTOR. SUBMIT INSPECTOR | | | RESUME' AND LICENSE DOCUMENTS TO KEN CONRAD, | | | 561-805-6666.A RESIDENT INSPECTOR PROGRAM IS | | | REQUIRED, ON THIS PROJECT (STEEL STRUCTURE ONLY), DUE | | | TO ONE OR MORE OF THE FOLLOWING: | | | - BUILDINGS/ADDITIONS OF TYPE I OR II | | | CONSTRUCTION | | | - ANY MAJOR STRUCTURAL ALTERATIONS | | | - STRUCTURES IN WHICH THE CONCRETE | | | DESIGN IS BASED ON COMPRESSIVE | | | STRENGTH (F'C) IN EXCESS OF 3000 PSI | | | - PILE DRIVING | | | - BUILDINGS OVER 20,000 SQFT IN AREA | | | - BUILDINGS OVER 2 STORIES IN HEIGHT | | | - BUILDING/STRUCTURES OF UNUSUAL DESIGN OR METHODS | | | OF CONSTRUCTION | | | | | | ALSO, PLEASE ARRANGE WITH KEN CONRAD (CHIEF BUILDING | | | INSPECTOR - TEL: 561 805 6666), A MEETING INVOLVING THE | | | OWNER, RESIDENT INSPECTOR, JOB INSPECTOR, CONTRACTOR | | | AND ENGINEER.THIS MUST BE DONE PRIOR TO PERMIT | | | ISSUANCE.THREE ORIGINAL SETS OF ALL DOCUMENTS ARE | | | REQUIRED FOR PERMITTING. | | | | | | 9. A901C, SECTION 507.2 UNLIMITED AREA NOT APPLICABLE | | | TO THIS PROJECT AS THIS IS A MIXED USE, A3 AND S1 | | | DECLARED.FBC507.9 UNLIMITED AREA FOR A4 OCCUPANCY | | | REQUIRES THAT THE FINISHED FLOOR BE 12? FROM GRADE | | | LEVEL AND HAS OTHER REQUIREMENTS FOR EXITING.I WAS | | | UNABLE TO LOCATE AN ALLOWANCE FOR A3 UNLIMITED AREA, | | | TYPE IIB.SEE FBC TABLE 503 AND CHAPTER 5. | | | | | | 10. SEE FBC302.3; THIS IS A MIXED OCCUPANCY BUILDING. | | | PLEASE SEE FBC302.3.2 REGARDING BUILDING RATIOS.IT | | | APPEARS THAT THIS BUILDING HAS BEEN DESIGNED IN | | | ACCORDANCE WITH FBC302.3.1 BUT DOES NOT COMPLY WITH THE | | | MORE STRINGENT REQUIREMENT OF A3, TYPE IIB.SEE OTHER | | | COMMENTS. | | | | | | 11. IF AREA MODIFICATIONS ARE USED FOR SPRINKLERS OR | | | OPEN AREA, PLEASE INCLUDE ALL CALCULATIONS ON THE PLAN. | | | FBC506. | | | | | | 12. A901C STATES THAT THE MEZZANINE COMPLIES WITH | | | FBC505.PLEASE SHOW COMPLIANCE BY STATING THE TOTAL | | | SQUARE FOOT AREA OF THE MEZZANINE, FBC505.2. | | | | | | 13. A901C, S1 AND A3 DECLARED, EMPLOYEE BREAK ROOM | | | SHOWN AS ACCESSORY, BUT THE ADMINISTRATION (BUSINESS) | | | AREAS, FIRST FLOOR AND MEZZANINE, WERE NOT ADDRESSED. | | | DECLARE TOTAL SF AREA FOR ADMINISTRATION AND SHOW | | | COMPLIANCE WITH FBC302.FIRE RESISTIVE RATED | | | CONSTRUCTION MAY BE REQUIRED BETWEEN THE B AND S AND B, | | | S AND A OCCUPANCIES (MEZZANINE). | | | | | | 14. A901C, DECLARE SQUARE FOOT AREA FOR THE ASSEMBLY | | | AND S1 OCCUPANCIES, ACCESSORY BREAK ROOM, FBC1004, | | | FBC302.ALSO SEE OTHER COMMENT; DECLARE SF AREA FOR | | | THE BUSINESS (ADMINISTRATION) AREA SHOWN ON THE FIRST | | | FLOOR AS WELL AS THE OFFICE IN THE MEZZANINE.IT IS | | | NOT CLEAR IF THIS IS ACCESSORY OR INCIDENTAL OR MIXED | | | OCCUPANCY, FBC302. | | | | | | 15. IS THE LUBE & OIL ROOM USED AS A REPAIR GARAGE, | | | FBC406.6, MAINTENANCE OR REPAIR OF AUTOMOTIVE OR | | | SIMILAR EQUIPMENT?SHOW COMPLIANCE ON THE PLAN WITH | | | SPECIAL REQUIREMENTS, IF ANY. | | | | | | 16. DO ANY OF THE AREAS INCLUDE HIGH PILED OR RACK | | | STORAGE OF COMBUSTIBLES, FBC413.3?SHOW COMPLIANCE ON | | | THE PLAN FOR ANY SPECIAL REQUIREMENTS, IF ANY. | | | 17. THERE ARE SEVERAL STORAGE AREAS SHOWN ON THE PLAN. | | | PLEASE NOTE MATERIALS TO BE STORED IN EACH AREA, | | | HAZARDOUS MATERIALS AND AMOUNTS, AS WELL AS COMPLIANCE | | | WITH ANY SPECIAL REQUIREMENTS, IF ANY, FBC413. | | | | | | 18. SHOW ACCESSIBLE EXITS, FBC11-4.1.3(9), A901C. | | | | | | 19. A901C, SEE THE EXIT AT THE BALED STORAGE AREA. | | | PLEASE SHOW THAT THIS IS NOT A REQUIRED ACCESSIBLE EXIT | | | DUE TO TRAVEL DISTANCE AS THIS EXIT DOES NOT PROVIDE | | | VERTICAL ACCESSIBILITY, FBC11-4.1.3(9). | | | | | | 20. THE LIFE SAFETY PLAN DOES NOT CORRELATE WITH A001C. | | | THERE ARE SEVERAL AREAS IN THE PROCESSING FLOOR WITH | | | DOORS AND WHAT APPEAR TO BE WALLS OR SOME OTHER | | | OBSTRUCTION PREVENTING PASSAGE.TRAVEL DISTANCE, | | | COMMON PATH OF TRAVEL, AND DEAD END CORRIDOR | | | REQUIREMENTS (FBC1015, FBC1016.3) CANNOT BE DETERMINED | | | UNLESS THESE OBSTRUCTIONS AS WELL AS THE EQUIPMENT IS | | | PLACED ON THE LIFE SAFETY PLAN.CONVEYOR BELTS, | | | CATWALKS, AND OTHER EQUIPMENT WHICH ARE SHOWN ON A001C | | | BUT WHICH DO NOT AFFECT THE PATH OF TRAVEL NEED NOT BE | | | SHOWN ON THE LIFE SAFETY PLAN, A901C. | | | | | | 21. S1 DECLARED, BUT CODE ANALYSIS ITEM 5, FIRE | | | PROTECTION SYSTEM, REFERS TO 903.2.3, REQUIREMENTS FOR | | | F1 OCCUPANCY.PLEASE REVISE CODE REFERENCE. | | | | | | 22. TO AVOID FIELD ISSUES AND TO ASSIST TRADES AND | | | INSPECTORS, ON SHEET A901C, PLEASE SHOW HORIZONTAL FIRE | | | RESISTANCE REQUIRED BETWEEN 1ST FLOOR AND MEZZANINE. | | | | | | 23. PLEASE CLARIFY .15IN FOR EGRESS COMPONENTS, A901C. | | | IT IS UNCLEAR WHERE THIS COMES FROM.SEE FBC TABLE | | | 1005.1. | | | | | | 24. STAIRWAYS ARE TO BE .3 PER OCCUPANT, NOT .2, FBC | | | TABLE 1005.1.REVISE A901C. | | | | | | 25. OTHER COMPONENTS IN THE MEANS OF EGRESS ARE TO BE | | | .2 PER OCCUPANT, NOT .15, REVISE A901C.THE DOORS DO | | | NOT COMPLY WITH THE MINIMUM REQUIREMENTS WHEN THE | | | OCCUPANT LOAD IS MULTIPLIED BY .2 RATHER THAN .15; FOR | | | INSTANCE, SEE STAIR 2 EXIT DOOR, 39.4INCHES REQUIRED | | | BUT ONLY 32 INCHES PROVIDED.CHECK ALL. | | | | | | 26. DECLARE OCCUPANT LOAD FOR THE SCALE HOUSE, | | | FBC1004. | | | | | | 27. SHOPS/ENGINEERING FOR THE STEEL CONTAINMENT WALL | | | PROVIDED BY CP MANUFACTURING A001C REVIEWED BY ENGINEER | | | AND PRIVATE PROVIDER WILL BE REQUIRED PRIOR TO | | | INSTALLATION; PROVISO ITEM. | | | | | | 28. A004C, SECTION 2, DOES NOT APPEAR TO SHOW THE DOOR | | | AND STAIR. | | | | | | 29. A003C AND OTHER SHEETS, PLANS SHOW SEVERAL LADDERS, | | | STAIRS, EQUIPMENT PLATFORMS, AND CATWALKS.SEE | | | FBC505.5.1, FBC505.5.2, 505.5.3, FBC CHAPTER 10. PLEASE | | | PROVIDE SHOPS WHICH SHOW CODE COMPLIANCE OR CONTACT ME | | | TO DISCUSS AT WHAT POINT DESIGNER/CONTRACTOR PROPOSES | | | TO SUBMIT THE DRAWINGS FOR THESE COMPONENTS. | | | | | | 30.SHOW LOCATION OF ANY ROOFTOP MECHANICAL EQUIPMENT | | | INCLUDING DISTANCE FROM EDGE, A006C.SEE FBC1012.5 AND | | | SHOW ANY REQUIRED GUARDS, LOCATION AND A DETAIL, | | | FBC1012. | | | | | | 31. THE STRUCTURAL CALCULATIONS (VP BUILDINGS), SCALE | | | HOUSE SHOP DRAWINGS, AND STRUCTURAL PLAN FOR THE MAIN | | | BUILDING HAS A PHOTOCOPY OF THE ENGINEER?S SIGNATURE. | | | AN ORIGINAL WET SIGNATURE IS REQUIRED AS WELL AS A | | | TITLE BLOCK WITH ALL INFORMATION REQUIRED BY | | | FAC61G15-23.002.ALSO PLEASE NOTE THE FOLLOWING AND | | | ADDRESS: | | | | | | A. THE STRUCTURAL CALCULATIONS AND PLANS FOR THE VP | | | BUILDING STRUCTURE WERE NOT REVIEWED BY THE PRIVATE | | | PROVIDER OR BY THE DESIGNER FOR THE BUILDING. | | | | | | B. THE CALCS AND PLANS STATE NOT FOR CONSTRUCTION; | | | PLEASE PROVIDE CONSTRUCTION SET.PLEASE ALSO SEE | | | FAC61G15; PRELIMINARY PLANS SHOULD NOT BE SIGNED AND | | | SEALED BY THE ENGINEER. | | | | | | C. PAGE 4 OF THE CALCULATIONS, OTHER SHEETS, PLANS, | | | REFER TO 2004 FLORIDA STATE BUILDING CODE; PLEASE | | | REVISE TO GOVERNING CODE WHICH IS FLORIDA BUILDING CODE | | | 2004 WITH 2007 REVISIONS/SUPPLEMENTS. | | | | | | D. PAGE 4 CALCULATIONS, OTHER SHEETS, AISC89 SHOULD | | | INCLUDE SUPPLEMENT 1, FBC35. | | | | | | E. ALL SIGNED AND SEALED SHEETS ARE TO INCLUDE ALL | | | INFORMATION REQUIRED BY FAC61G15-23.002.IN THE PAST, | | | THIS ISSUE AS WELL AS THE PHOTOCOPIED SIGNATURE HAS | | | CAUSED PERMIT DELAYS.PLEASE ONLY SUBMIT PLANS WHICH | | | COMPLY, ESPECIALLY AS THE ENGINEER HAS BEEN ADVISED OF | | | THESE REQUIREMENTS ON AT LEAST TWO OTHER PROJECTS IN | | | THE PAST.THE ENGINEER?S COOPERATION WILL HELP TO | | | EXPEDITE PLAN REVIEW AND PERMIT ISSUANCE. | | | | | | 32. FLORIDA STATE OR LOCAL PRODUCT APPROVAL OR | | | MIAMIDADE NOA REQUIRED FOR THE ROOF PANELS, FAC9B72. | | | | | | 33. PRODUCT APPROVALS ARE TO BE APPROVED BY DESIGNER OF | | | RECORD (SHOP DRAWING REVIEW STAMP OR LETTER), | | | FBC*106.3.3.AS THEY ARE A PART OF THE BUILDING | | | ENVELOPE AND REQUIRED TO DETERMINE CODE COMPLIANCE, THE | | | PRODUCT APPROVALS ARE ALSO TO BE REVIEWED BY THE | | | PRIVATE PROVIDER. | | | | | | 34. THE PRODUCT APPROVALS SUBMITTED HAVE NOT YET BEEN | | | REVIEWED AS DESIGN PRESSURES HAVE NOT BEEN SPECIFIED. | | | HOWEVER PLEASE NOTE THAT THE COIL DOOR PRODUCT APPROVAL | | | IS FOR A 16FT WIDE DOOR MAXIMUM, BUT A 20FT DOOR IS | | | SHOWN ON A002C. | | | | | | 35. FOR FL4553, CECO DOOR, PROVIDE THE EVALUATION | | | REPORT AND INSTALLATION INSTRUCTIONS FROM THE WEBSITE, | | | WWW.FLORIDABUILDING.ORG. | | | | | | 36. DECLARE WIND DESIGN CRITERIA, FBC1603.1.4.THIS IS | | | REQUIRED FOR THE STRUCTURE, AND COMPONENT AND CLADDING | | | PRESSURES REQUIRED BUT NOT PROVIDED. | | | | | | 37. FOR THE PEERLESS HORIZONTAL SLIDER, PROVIDE FLORIDA | | | STATE PRODUCT APPROVAL OR MIAMIDADE NOA, FAC9B72.A | | | TEST REPORT WAS PROVIDED BUT ADDITIONAL INFORMATION IS | | | REQUIRED. | | | | | | 38. THE VACRO PRUDEN BUILDINGS MIAMIDADE NOA SUBMITTED | | | FOR THE WALL PANELS IS EXPIRED AS OF 7/1/08.PLEASE | | | PROVIDE A CURRENT PRODUCT APPROVAL, FAC9B72. | | | | | | 39. CALCULATIONS FOR VERSAKING BUILDINGS WERE | | | SUBMITTED.PLEASE NOTE THE FOLLOWING: | | | | | | A. THE CALCS ARE TO BE REVIEWED BY THE PRIVATE PROVIDER | | | AND BY THE DESIGNER OF RECORD. | | | | | | B. CALCS REFER TO PORTAKING DRAWINGS.PLEASE SUBMIT. | | | DRAWINGS ARE TO BE REVIEWED BY DESIGNER OF RECORD AND | | | THE PRIVATE PROVIDER. | | | | | | C. IT APPEARS THAT THE STRUCTURES WILL BE INSTALLED | | | INSIDE OF THE VP BUILDING AS NO WIND LOADS WERE | | | PROVIDED.PLEASE CLARIFY ON THE PLAN; SHOW LOCATION OF | | | THE PROPOSED PORTAKING STRUCTURES ON THE FLOOR PLAN. | | | | | | D. INCLUDE THE DOORS FOR THE STRUCTURES ON A DOOR | | | SCHEDULE OR PROVIDE INFORMATION IN ANOTHER FORMAT TO | | | SHOW COMPLIANCE WITH ACCESSIBILITY FBC11 AND OTHER | | | REQUIREMENTS FBC10. | | | | | | E. CALCULATIONS ARE TO BE EITHER SIGNED, SEALED AND | | | DATED WITH A TITLE BLOCK ON EACH SHEET, OR AN INDEX | | | SHEET IN ACCORDANCE WITH FAC61G15-23 USED.PLEASE | | | ADDRESS. | | | | | | F. GOVERNING CODE IS TO INCLUDE 2007 | | | REVISIONS/SUPPLEMENTS. | | | | | | 40. THE 3 RING BINDER ENTITLED TECHNICAL SPECIFICATIONS | | | HAS NOT BEEN REVIEWED BY THE PRIVATE PROVIDER.ALSO IT | | | WAS NOT PREPARED IN ACCORDANCE WITH FAC61G1-16.002, | | | 003; EITHER EVERY SHEET SIGNED AND SEALED OR AN INDEX | | | SHEET USED.THIS BINDER MAY BE REMOVED IF ALL | | | INFORMATION REQUIRED TO SHOW CODE COMPLIANCE IS | | | INCLUDED IN THE PLANS.OTHERWISE, PLEASE SUBMIT | | | REVIEWED AND IN COMPLIANCE WITH FAC RULES.PLEASE NOTE | | | THAT NORMALLY THE ENTIRE DOCUMENT IS NOT REVIEWED; IT | | | WILL BE INCLUDED WITH THE RECORD SET WITH THE PROVISO | | | IN ACCORDANCE WITH FBC2004 AND PLAN. | | | | | | 41. THE DOOR SCHEDULE IN THE TECHNICAL SPECIFICATIONS | | | BINDER DOES NOT INCLUDE ALL OF THE DOORS ON THE DOOR | | | SCHEDULE IN THE PLAN; FOR INSTANCE, DOORS 102 1, 124 5, | | | 205 2.IF THE TECHNICAL SPECIFICATIONS BINDER REMAINS | | | A PART OF THE PERMIT SET, PLEASE CORRELATE. | | | | | | 42. THE WALL AT DOOR 132 1 IS NOT SHOWN AS A FIRE | | | RESISTANCE RATED WALL ALTHOUGH SPECIFIED AS FIRE | | | RESISTANCE RATED ON THE LIFE SAFETY PLAN A901C. | | | | | | 43. STAIR 1 OPENS INTO THE ELEVATOR LOBBY.SEE | | | FBC1019.1.1.NO OPENINGS PERMITTED IN THE STAIR | | | ENCLOSURE OTHER THAN THOSE REQUIRED FOR ACCESS, AND | | | THOSE OPENINGS ARE TO BE RATED. | | | | | | 43. DOOR 201 1, ASSEMBLY TO STORAGE, DOES NOT SHOW FIRE | | | RESISTANCE, SEE FBC715.3. | | | | | | 44. SEE FBC TABLE 1016.1, CORRIDORS 203 AND 205 FROM | | | VISITOR?S GALLERY TO STAIRS TO HAVE 1 HOUR FIRE | | | RESISTIVE RATING AND THEREFORE DOORS 203 1, 204 1, 205 | | | 1, 206 1, 200 1, TO BE RATED IN ACCORDANCE WITH | | | FBC715.3. | | | | | | 45. A FIRE RATED WALL IS SHOWN BETWEEN TOOL & EQUIPMENT | | | ROOM AND THE PROCESSING AREA, BUT NO RATING IS SHOWN | | | FOR DOOR 124 3.PLEASE CLARIFY DESIGN CRITERIA. | | | | | | 46. SEE FBC715.3, DOOR 201 1 AND WINDOWS W5 TO HAVE | | | FIRE PROTECTION IN ACCORDANCE WITH FBC TABLE 715.3 IF | | | AN OCCUPANCY SEPARATION IS REQUIRED.PLEASE SEE OTHER | | | REQUIREMENTS REGARDING FBC302, FBC 5, REGARDING | | | BUILDING HEIGHT AND AREA.AN UNLIMITED BUILDING SIZE | | | WAS DECLARED BUT THIS BUILDING DOES NOT COMPLY | | | (ASSEMBLY LIMITATIONS).DEPENDING ON HOW COMPLIANCE IS | | | SHOWN, VERTICAL AND HORIZONTAL OCCUPANCY SEPARATION MAY | | | BE REQUIRED. | | | | | | 47. STAIR 2 SPECIFIES A 1 HOUR WALL ON THE EXTERIOR | | | SIDE OF THE STAIR, A101C, BUT NO FIRE RATING FOR THE | | | DOOR 136 1.CLARIFY DESIGN INTENT. | | | | | | 48. A114C, 2 HOUR BLOCK SPECIFIED.PLEASE PROVIDE SPEC | | | SHEETS AS 2 HOUR IS PROPRIETARY. | | | | | | 49. UL905 SPECIFIED A114C, PROVIDE A COMPLETE DETAIL | | | FOR THIS AND ANY OTHER UL ASSEMBLIES SPECIFIED ON THE | | | PLAN. | | | | | | 50. PROVIDE PENETRATION DETAILS, FBC712. | | | | | | 51. SEE STAIR SHAFT DETAILS A114C, DOES THIS GO TO THE | | | UNDERSIDE OF THE DECK?SEE FBC706.4, 1019.1, PROVIDE A | | | DETAIL SHOWING COMPLIANCE. | | | | | | 52. A112C SPECIFIES PLYWOOD.PLEASE CLARIFY USE OF | | | COMBUSTIBLE IN THIS TYPE IIB BUILDING, FBC603. | | | | | | 53. SPECIFY INTERIOR FINISH CLASSIFICATION, FBC TABLE | | | 803.5. | | | | | | 54.THE WALL BETWEEN THE VISITOR?S GALLERY AND THE | | | OTHER ADJACENT MEZZANINE AREAS DOES NOT SHOW ANY FIRE | | | RESISTIVE RATING.PLEASE SEE OTHER COMMENTS; IS THIS | | | ALL ASSEMBLY OCCUPANCY, OR DOES IT REQUIRE AN OCCUPANCY | | | SEPARATION?DESIGN INTENT IS NOT CLEAR. | | | | | | 55. FBC13-101.1, ENERGY CALCS REQUIRED FOR BOTH THE | | | MAIN BUILDING AND FOR THE SCALE HOUSE. | | | | | | 56. JANITOR?S ROOM 138 IS TO BE ACCESSIBLE | | | FBC11-4.1.1(3), WORK AREAS ARE TO BE DESIGNED SO THAT | | | EMPLOYEES CAN APPROACH, ENTER, AND EXIT THE AREAS. SHOW | | | TURNING RADIUS. | | | | | | 57. PROVIDE INFORMATION (SPEC SHEETS SUGGESTED) FOR THE | | | DOOR AT THE VESTIBULE, 112 2 TO SHOW COMPLIANCE WITH | | | FBC11-4.13 AND FBC10. | | | 58. PROVIDE THE ANTICIPATED OCCUPANT LOAD FOR THE AREA | | | AT THE BOTTOM OF THE COMMUNICATING NON EGRESS STAIR. | | | THIS APPEARS TO BE 3FT4IN.10 OCCUPANTS SHOWN FOR DOOR | | | 134 1, PLEASE CLARIFY HOW YOU HAVE DETERMINED | | | ANTICIPATED OCCUPANTS PER DOOR. | | | | | | 59. SEE FBC1016.4, AIR MOVEMENT IN CORRIDORS.PLEASE | | | REMOVE SUPPLY, RETURN, EXHAUST, RELIEF OR VENTILATION | | | AIR DUCTS FROM EXIT ACCESS CORRIDORS, SEE OTHER | | | COMMENTS.PLEASE NOTE THAT THERE ARE TWO HALLS IN THE | | | MEZZANINE WHICH SERVE AS CORRIDORS. | | | | | | 60. SEE FBC1019.1.2, PENETRATIONS INTO THE STAIRS ARE | | | PROHIBITED EXCEPT AS PERMITTED BY THIS CODE SECTION. | | | PLEASE REVISE PLANS. | | | | | | 61. DETAIL 1 A007C STATES TO SEE STRUCTURAL DRAWINGS | | | FOR THE STAIR RAIL DETAIL.PLEASE SPECIFY DETAIL, | | | NUMBER AND PAGE. THERE ARE MANY REFERENCES THROUGHOUT | | | THE A SHEETS TO SEE STRUCTURAL DWGS.PLEASE REVISE ALL | | | TO REFER SPECIFICALLY TO A DETAIL. | | | | | | 62. A114C, SPECIFY GUARD PICKET SPACING FBC1012. | | | | | | 63. GUARDRAILS AND HANDRAILS, SPECIFY DESIGN STRENGTH | | | TO COMPLY WITH FBC1607.7. | | | | | | 64. SEE 3 A007C, THE HANDRAIL IS NOT CONTINUOUS. A106C | | | HANDRAIL EXTENSIONS AT BOTTOM NOT SHOWN. PLEASE PROVIDE | | | DETAILS AND CORRELATE A SHEETS. | | | | | | 65. 2 A107 IS LOCATED ON SHEET A102 RATHER THAN 101. IS | | | ACCESSIBILITY REQUIRED?PLEASE CONFIRM THAT ALL | | | DETAILS ARE REFERRED TO PROPERLY ON THE PLAN. | | | | | | 66. IT APPEARS THAT THE CHAIN LINK FENCE AND GATE | | | OBSTRUCT THE MEANS OF EGRESS CONTINUITY, FBC1003.1. THE | | | GATE AND COIL DOOR DO NOT MEET ANY OF THE REQUIREMENTS | | | AS A MEANS OF EGRESS COMPONENT OF CHAPTER 10. | | | | | | 67. PROVIDE A SITE PLAN AND A SURVEY TO BE INCORPORATED | | | INTO THIS PLAN TO SHOW COMPLIANCE WITH THE OPEN SPACE | | | REQUIREMENT FBC507.2, REVIEWED BY PRIVATE PROVIDER, AS | | | WELL AS ACCESSIBILITY REQUIREMENTS FOR PARKING AND | | | ACCESSIBLE ROUTE, SEE OTHER COMMENTS.PLANS WERE | | | SUBMITTED WHICH WERE PREPARED BY THE LANDSCAPE | | | ARCHITECT; IT IS NOT CLEAR IF THE LANDSCAPE PLAN IS TO | | | BE USED TO SHOW CODE COMPLIANCE WITH LIFE SAFETY, FBC | | | CHAPTER 5, AND ACCESSIBILITY.PLEASE PROVIDE A PLAN TO | | | BE USED FOR THAT PURPOSE OR INCORPORATE THE REQUIRED | | | INFORMATION INTO THE C SHEETS. | | | | | | 68. THE SITE PLAN IS TO DECLARE TOTAL NUMBER OF PARKING | | | SPACES AND TOTAL NUMBER OF ACCESSIBLE PARKING SPACES | | | FBC11-4.1.2(5)(A). | | | | | | 69. THE ACCESSIBLE PARKING SPACES ARE TO BE DISPERSED | | | FBC11-4.6.2.PLEASE SHOW THE DOORS ON THE SITE PLAN IN | | | RELATION TO THE PROPOSED ACCESSIBLE PARKING SPACES AND | | | ALSO SHOW ACCESSIBLE ENTRANCES. | | | | | | 70. SHOW THE ACCESSIBLE ROUTE FROM THE PUBLIC WAY TO | | | THE ACCESSIBLE BUILDING ENTRANCE FBC11-4.3.2.1(1). | | | | | | 71. PROVIDE A DETAIL FOR THE ACCESSIBLE PARKING SPACE | | | FBC11-4.6 AND SHOW WIDTH OF ACCESSIBLE ROUTE, NO LESS | | | THAN 44INCHES, FBC11-4.6.2(1). | | | | | | 72. PLEASE NOTE THAT THE FOUNDATION PERMIT HAS NOT BEEN | | | ISSUED; THEREFORE, ANY INFORMATION INCLUDED IN THAT | | | PERMIT CANNOT BE USED TO SHOW CODE COMPLIANCE FOR THIS | | | PERMIT AT THIS TIME. | | | | | | 73. SHOW LOCATION OF STROBES, FBC11-4.28.1. | | | | | | 74. ELEVATOR SIGNAGE TO COMPLY WITH FBC11-4.10.5, CALL | | | BUTTONS WITH FBC11-4.10.3. | | | | | | 75. SEE FC1009.4, STAIR LANDINGS, INTERMEDIATE LANDING | | | IS 44 IN, 48 INCHES REQUIRED, A113C. | | | | | | 76. PROVIDE A SPECIFICATION FOR ATTACHMENT OF THE GRAB | | | BARS TO THE SHEET METAL TO SHOW COMPLIANCE WITH | | | FBC1607.7.1.1, FBC11-4.26.3. | | | | | | 77. PROVIDE A SPECIFICATION FOR ATTACHMENT OF THE | | | BACKING FOR THE GRAB BARS (A111C) TO SHOW COMPLIANCE | | | WITH FBC1607.7.1.1, FBC11-4.26.3.DETAIL STATES | | | SCREWED TO STUD BUT DOES NOT SPECIFY SIZE OF SCREWS OR | | | DISTANCE APART, DOES NOT SPECIFY A WIDTH FOR THE 22G | | | SHEET METAL BACKING. | | | | | | 78. SEE FBC1006 AND SHOW COMPLIANCE.IT IS NOT CLEAR | | | WHAT ILLUMINATION WILL BE PROVIDED FOR THE EQUIPMENT | | | PLATFORMS, STAIRS. | | | | | | 79. INFORMATIONAL ONLY; SEPARATE PERMITS REQUIRED FOR | | | SIGNS.THEY ARE USUALLY APPLIED FOR BY THE SIGN | | | CONTRACTOR PRIOR TO INSTALLATION. | | | | | | 80. PLEASE SHOW COMPLIANCE WITH FBC910, SMOKE AND HEAT | | | VENTS.PROVIDE CALCULATIONS ON THE PLAN AND SHOW | | | COMPLIANCE WITH ALL REQUIREMENTS. | | | | | | 81. FBC505.5.2, FP101C DOES NOT MAKE REFERENCE TO | | | SPRINKLERS ABOVE AND BELOW PLATFORMS.ON THE SPRINKLER | | | HEAD LAYOUT PLAN, SHOW COMPLIANCE. | | | | | | 82. SEE OTHER COMMENTS.IT IS NOT CLEAR WHETHER THE | | | EXIT LIGHTS PROVIDED ARE ADEQUATE, FBC1006.3; CANNOT | | | DETERMINE WHETHER OR NOT EQUIPMENT OBSTRUCTS THE EXIT | | | LIGHTS.PLEASE ADDRESS ON THE PLAN, PREFERABLY THE | | | LIFE SAFETY PLAN. | | | | | | 83. SEE FBC1503.6, PROVIDE A DETAIL FOR CONDENSATE | | | LINES AND ROOF DOWNSPOUTS. | | | | | | 84. WHEN RESUBMITTING, PLEASE INCLUDE A DETAILED | | | RESPONSE LETTER STATING HOW EACH ITEM WAS ADDRESSED, | | | INCLUDING PAGE NUMBER(S) IF POSSIBLE.THIS WILL HELP | | | TO EXPEDITE PLAN REVIEW. | | | | | | 85. SOME OF THE PLANS HAVE BEEN RETAINED.WHEN | | | RESUBMITTING, PLEASE SUBMIT THREE COMPLETE SETS. THE | | | PLANS WHICH HAVE BEEN RETAINED WILL NOT BE RELEASED FOR | | | PERMITTING PURPOSES.CONTACT DEWEY PALMER IF YOU HAVE | | | QUESTIONS REGARDING THIS ISSUE. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
16 |
Status |
P |
Date |
2009-09-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-09-24 |
Time |
16:04 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-09-24 |
Time |
16:04 |
Sent To |
PC |
|
| Notes |
| 2009-09-24 16:05:13 | REVISED PANELS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
15 |
Status |
P |
Date |
2009-08-31 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-08-31 |
Time |
12:10 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-08-31 |
Time |
12:10 |
Sent To |
PC |
|
| Notes |
| 2009-08-31 12:10:48 | | | | | | | ** REDLINED REVIEW ** | | | | | | | | | | | | 1) NOTE: LARGEST BRANCH CIRCUIT ON SCS IS SHOWN AS | | | 30AMP. AS ELP1 HAS NOW BEEN REVISED TO REMOVE FEED TO | | | SUB PANEL, THEN THE ACTUAL LARGEST BREAKER IS 2-P | | | 20AMP. | | | | | | 2) NOTE: E-117 NEEDS TO BE REVISED FOR ELP1 | | | | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
14 |
Status |
F |
Date |
2009-07-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-07-16 |
Time |
09:55 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-07-16 |
Time |
09:55 |
Sent To |
|
|
| Notes |
| 2009-07-16 09:56:02 | | | | | | | ** DENIED ** | | | | | | SUBMISSION OF THE SELECTIVE COORDINATION STUDY. | | | | | | ** THE FOLLOWING COMMENTS ARE BASED ON THE SELECTIVE | | | COORDINATION STUDY AND NEW COMMENTS DERIVED DURING | | | REVIEW. A CALL WAS MADE TO GIPE AND ASSOCIATES AND | | | SPOKE TO MICHAEL PURTELL. | | | | | | ** IN THE NOTES BELOW THE SELECTIVE COORDINATION STUDY | | | WILL BE NOTED AS SCS. | | | | | | 1) NOTE: NEW COMMENT: PLEASE SEE 700.9(B). PLEASE SEE | | | NEC 2005 HANDBOOK COMMENTARY FOR WIRING OF SYSTEMS. | | | PLEASE EXPLAIN HOW OPTIONAL STAND-BY LOADS SUCH AS | | | CEILING FANS, SCALES AND OTHER GENERAL LOADS MAY BE | | | PART OF THE LIFE SAFETY/ EMERGENCY SYSTEM. THIS WAS ON | | | PREVIOUS PLANS HOWEVER WAS MISSED BY REVIEWER. | | | STAND-BY LOADS MAY BE FED FROM SEPARATE FEED ON | | | GENERATOR WITH SEPARATE TRANSFER SWITCH OR REMOVE ALL | | | LOADS FROM EMERGENCY PANELS. | | | IF ELP-1 WAS A * SWITCHBOARD * THEN THERE COULD BE A | | | SEPARATE BRANCH FEED TO A STAND-BY ATS WHICH WOULD THEN | | | FEED TERP-1. | | | | | | 2) NOTE: PLEASE COORDINATE THE SCS WITH THE PLANS. | | | PLEASE SEE THE SCS RISER AS THIS INDICATES ONLY ONE SET | | | OF FEEDERS TO ATS-2 WHERE THE PLANS ON RECORD INDICATES | | | 2 SETS OF PARALLEL 3/0. | | | | | | 3) NOTE: PLEASE EXPLAIN THE SCS RISER WHICH SEEMS TO | | | INDICATE 100HP AND 50HP FOR FIRE PUMP. | | | | | | 4) NOTE: PLEASE COORDINATE THE BREAKER ON THE GENERATOR | | | FOR ATS-2E WHICH SHOWS 250A ON SCS RISER AND 200AMP ON | | | PLANS. | | | | | | 5) NOTE: ALL OCP DEVICES ON THE GENERATOR SHALL BE PART | | | OF THE STUDY. PLEASE KNOW BASED ON THE 60AMP BREAKER ON | | | ELP-1 THIS WOULD ALSO BE ON STUDY. ALTHOUGH PLEASE SEE | | | COMMENT #1 ABOVE AS THIS DOES AFFECT THE RISER AS IT | | | STANDS. | | | | | | | | | 240.12, 701.18, 700.27 | | | | | | | | | | | | | | | ** IMPORTANT ** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED | | | INTO TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
13 |
Status |
P |
Date |
2009-05-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-05-18 |
Time |
14:51 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-05-18 |
Time |
14:51 |
Sent To |
|
|
| Notes |
| 2009-05-18 14:52:01 | REVS FOR BALER |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
12 |
Status |
P |
Date |
2009-04-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-04-20 |
Time |
14:28 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-04-20 |
Time |
14:28 |
Sent To |
PC |
|
| Notes |
| 2009-04-20 14:28:35 | ELEC REV E 107 CR5, 120 CR3 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
11 |
Status |
F |
Date |
2009-04-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-04-12 |
Time |
11:03 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-04-12 |
Time |
11:03 |
Sent To |
PC |
|
| Notes |
| 2009-04-12 11:03:50 | ** DENIED** | | | | | | 1) NOTE: THE PLANS SUBMITTED DO NOT CONTAIN THE SAME | | | SIGNATURE AS ALL OTHER PLANS IN FILE FOR THE SAME | | | ENGINEER OF RECORD. THE PLANS ARE SIGNED WITH A | | | SIGNATURE WHICH IS COMPLETELY DIFFERENT. PLEASE SEE FS | | | 471.023 AND FAC 61G15-23.002. | | | PLANS SHALL BE SIGNED AND SEALED BY THE ENGINEER BY OF | | | RECORD. AN ENGINEER MAY NOT DESIGNATE ANOTHER PERSON TO | | | SIGN PLANS. THIS HAS BEEN CONFIRMED ON MANY OCCASIONS | | | WITH THE ATTORNEYS AND INVESTIGATORS FOR THE FLORIDA | | | BOARD OF PROFESSIONAL ENGINEERS. PLEASE CONTACT THE | | | BOARD, JERRY ONGLEY, OR JACK BEAMISH WITH ANY QUESTIONS | | | ON THIS MATTER. | | | ** THIS REVIEWER HAD PLACE PHONE CALL TO THE ENGINEER'S | | | OFFICE ON THE 3RD OF APRIL IN WHICH THE OFFICE SAID THE | | | ENGINEER WAS OUT ON A VACATION. THIS IS THE SAME DATE | | | ON PLANS WHEN SIGNED AND SEALED. | | | ** ONE SET OF PLANS ARE BEING RETAINED BY THIS OFFICE. | | | | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
10 |
Status |
P |
Date |
2009-04-02 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-04-02 |
Time |
19:26 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-04-02 |
Time |
19:26 |
Sent To |
|
|
| Notes |
| 2009-04-02 19:26:59 | REV 104, 105 AND 108 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
9 |
Status |
F |
Date |
2009-04-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-04-01 |
Time |
17:49 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-04-01 |
Time |
17:49 |
Sent To |
PC |
|
| Notes |
| 2009-04-01 17:50:04 | ** DENIED REVIEW ** | | | | | | 1) NOTE: SHEETS E107, 120 AND 121 SHALL COORDINATE WITH | | | THE ELECTRICAL PLANS FOR THE EQUIPMENT ELECTRICAL | | | ENGINEERED PLANS. | | | PLEASE SEE THE PANEL PP-EC IS STILL NOT LISTED ON THE | | | MSB SWITCHBOARD. | | | THE RISER SUBMITTED FOR THE EQUIPMENT ENGINEERED PLANS | | | ALONG THE REVISED RISER ON E120 SHOWS A 175AMP BREAKER | | | FEEDING PANEL PP-EC HOWEVER PLEASE TAKE A LOOK AT MSB | | | SCHEDULE. THE ONLY 175 BREAKER ON EITHER E107 OR E120 | | | IS THE 175AMP BREAKER WHICH IS STATED FOR THE | | | *RELOCATED BALER*. TO DATE THERE IS NO PP-EC LISTED ON | | | EITHER MSB SCHEDULE. | | | PLEASE COORDINATE ALL. | | | PLEASE REVISE LOAD CALCULATIONS. | | | 408.4, 310.16, 240, 220 ETC | | | | | | 2) NOTE: SHEET E-1 THROUGH E-4 HAS BEEN STAMPED FOR | | | ELECTRICAL ENGINEERED EQUIPMENT PLANS. THIS SCOPE OF | | | WORK IS NOT PART OF THE BASE BUILDING ELECTRICAL. IN | | | FACT THIS SCOPE OF WORK IS DONE BY A SEPARATE | | | ELECTRICAL CONTRACTOR. | | | | | | A PHONE CALL WAS PLACED TO THE BASE BUILDING ELECTRICAL | | | ENGINEER FOR A RETURN CALL. | | | ONE SET OF ELECTRICAL PLANS FOR BASE BUILDING HAVE BEEN | | | RETAINED BY THIS REVIEWER. | | | | | | | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
8 |
Status |
N |
Date |
2009-03-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-03-27 |
Time |
14:35 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-03-27 |
Time |
14:35 |
Sent To |
|
|
| Notes |
| 2009-03-27 14:36:28 | HORN/ STOBE RFI, PER BUIDLING AND FIRE REVIEW. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
F |
Date |
2009-03-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-03-26 |
Time |
18:15 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-03-26 |
Time |
18:15 |
Sent To |
PC |
|
| Notes |
| 2009-03-26 18:15:14 | ** DENIED REVIEW ** | | | | | | ** PLEASE SEE NOTES FROM PREVIOUS REVIEW. | | | | | | 1) NOTE: PLEAS SUBMIT A COMPLETE COORDINATION STUDY. | | | THIS NEEDS TO INCLUDE COORDINATION RISER, STUDY AND | | | TIME CURVES. THE SUBMITTED SHORT CIRCUIT ANALYSIS IS | | | NOT ALL THE INFORMATION THAT IS NEEDED TO VERIFY | | | MINIMUM CODE COMPLIANCE. IT WAS GONE OVER ON THE PHONE | | | THAT THE COMPLETE STUDY ALONG WITH TIME CURVES. | | | 700.27, 701.8, 240.12 ETC. | | | *** IT IS IMPORTANT TO KNOW THAT SINCE THE COORDINATION | | | STUDY HAS YET TO BE SUBMITTED THERE MAY BE NEW COMMENTS | | | ON THE NEXT REVIEW WHICH CAN NOT BE MADE AT THIS TIME. | | | | | | 2) NOTE: AS STATED ON PREVIOUS REVIEW. THE ENGINEER FOR | | | THE BASE BUILDING ELECTRICAL PLANS NEEDS TO SIGN THE | | | SHOP DRAWING REVIEW STAMPED OF THE SUBMITTED ELECTRICAL | | | ENGINEERED SYSTEMS PLANS. | | | THE PERSON SIGNED IS NOT THE ENGINEER OF RECORD. ALL | | | ELECTRICAL WORK, LOADS ETC IN THE BUILDING BEFORE THE | | | CERTIFICATE OF OCCUPANCY IS ISSUED IS UNDER THE REVIEW | | | AND RESPONSIBILITY OF THE BASE BUILDING DESIGN | | | PROFESSIONAL TO BE AWARE OF TRACK AND ADJUST MAIN | | | PLANS. | | | FS 471.025 | | | | | | 3) NOTE: PLEASE SEE BASE BUILDING RISER AND SUBMITTED | | | ELECTRICAL ENGINEERING PLANS ARE STILL NEED | | | COORDINATION. PLEASE SEE E120CR1 WHICH IS NOW NOT | | | REVISED TO MATCH THE UPDATED MSB ON E107CR4. | | | FOR EXAMPLE: REVISED MCC1 ON E107 | | | FOR EXAMPLE: REVISED PP-EC ON E120 WHICH IS NOT ON E | | | 107. | | | PLEASE PROVIDE LOADS/CIRCUITS FOR THE LC. (LOAD | | | CENTERS) LC210- LC217 | | | 215.5, 408.4, 230, 240 SECTIONS GIVEN FOR COORDINATION | | | OF ELECTRICAL PLANS. | | | THE TOTAL LOAD SHOWN ON MSB IS NOT ACCURATE. PLEASE | | | UPDATE WITH ALL NEW LOADS. | | | | | | 4) NOTE: FOR CONTRACTOR INFORMATION: IF THE EQUIPMENT | | | PLANS AND BASE BUILDING PLANS ARE CLEARED UP BASED ON | | | NOTES #2 AND #3 THE EQUIPMENT CONTRACTOR WILL BE ABLE | | | TO APPLY FOR PERMIT. COMMENT #1 MAY REMAIN OUTSTANDING. | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
F |
Date |
2009-03-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-03-10 |
Time |
19:15 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-03-10 |
Time |
19:15 |
Sent To |
PC |
|
| Notes |
| 2009-03-10 19:15:57 | ** DENIED REVISIONS ** | | | | | | REVISION OF PLANS FOR BASE BUILDING AND SUBMITTAL OF | | | ELECTRICAL MANUFACTURING EQUIPMENT PLANS. | | | | | | 1) NOTE: THE REVISED SHEETS FOR ARCHITECTURAL NOTES AND | | | SHEET E104CR4 ARE OK. | | | | | | 2) NOTE: ELECTRICAL RISER SHEET E107CR3 WILL REMAIN IN | | | FAILED STATUS UNTIL COORDINATION WITH MANUFACTURING | | | PLANS AND REVISIONS ARE MADE. | | | SEE NOTE #4 BELOW AND OTHER NOTES. | | | | | | ** REVIEW FOR PLANS BY ASSOCIATED ENGINEERING | | | INCORPORATED: | | | | | | 3) NOTE: THE TITLE BLOCKS NEED TO CONTAIN THE PRINTED | | | NAME AND LICENSE NUMBER OF THE PROFESSIONAL ENGINEER | | | EVEN IF THIS INFORMATION IS IN THE SAID SEAL OF THE | | | SAME DESIGN PROFESSIONAL. | | | FLORIDA ADMINISTRATIVE CODE 61G15-23.002 | | | | | | 4) NOTE: PLANS SHOWS GFI PROTECTION FOR THE 3000AMP | | | MAIN DISTRIBUTION CENTER. PLEASE SEE 240.13,230.95 AS | | | THIS SHOULD BE NOTED OR IDENTIFIED AS GFP. (GROUND | | | FAULT PROTECTION) GFI IS FOR PERSONNEL PROTECTION. | | | THE RISER NOTES # 7 ON E107CR3 STILL NOTES GFI EVEN AS | | | THE MSB PANEL STATES GFP. | | | PLEASE COORDINATE. | | | | | | 5) NOTE: PLEASE SEE MCC1 AS THIS EQUIPMENT IS SHOWN | | | RATED AT 450AMP YET THERE IS A 500AMP BREAKER ON E107 | | | SHOWN FEEDING THIS EQUIPMENT. THIS IS THE SAME ON THE | | | EQUIPMENT PLANS. | | | 240, 230, 310, 110.14 ETC. | | | | | | 6) NOTE: PLEASE SEE THE EQUIPMENT PLANS AS THEY CLEARLY | | | INDICATE A 600AMP DISTRIBUTION SECTION WHICH IS NOT ON | | | THE E107 SHEET/ RISER. | | | NO INFORMATION IS PROVIDED FOR THIS PROVISION ON THE | | | BASE BUILDING PLANS. | | | FBC 106.1.1, 106.1.2, 106.3.5.1.2, COORDINATION AND | | | ADDITIONAL INFORMATION ON RECORD PLANS. NEC 220,215.5, | | | 240.4,230 ETC. THESE SECTIONS ARE GIVEN AS GENERAL | | | CHAPTERS AS PLANS ARE NOT COORDINATED. IT IS NOT | | | POSSIBLE TO DO A SPECIFIC REVIEW. | | | | | | 7) NOTE: PLEASE SEE THE ELECTRICAL EQUIPMENT RISER | | | INDICATES A NEW 300AMP BREAKER ON THE MSB FEEDING A NEW | | | 225KVA TRANSFORMER. NEITHER OF THESE TWO ITEMS IS ON | | | THE BASE BUILDING ELECTRICAL RISER DIAGRAM ON SHEET | | | E107. | | | NO INFORMATION IS PROVIDED FOR THIS PROVISION ON THE | | | BASE BUILDING PLANS. | | | FBC 106.1.1, 106.1.2, 106.3.5.1.2, COORDINATION AND | | | ADDITIONAL INFORMATION ON RECORD PLANS. NEC 220,215.5, | | | 240.4,230, 408.4ETC. THESE SECTIONS ARE GIVEN AS | | | GENERAL CHAPTERS AS PLANS ARE NOT COORDINATED. IT IS | | | NOT POSSIBLE TO DO A SPECIFIC REVIEW. | | | | | | 8) NOTE: PLEASE SEE THE ELECTRICAL EQUIPMENT RISER AS | | | THIS RISER CONTAINS TEN ELECTRICAL PANELS WHICH ARE | | | IDENTIFIED AS SE1 THROUGH SE 10. NONE OF THESE PANELS | | | ARE ON THE BASE BUILDING ELECTRICAL PLANS ON E107. | | | PLEASE SEE NOTES # 6 AND 7 ABOVE AS THESE ARE DIRECTLY | | | AFFECTED BY THESE ITEMS. | | | NO INFORMATION IS PROVIDED FOR THIS PROVISION ON THE | | | BASE BUILDING PLANS. | | | FBC 106.1.1, 106.1.2, 106.3.5.1.2, COORDINATION AND | | | ADDITIONAL INFORMATION ON RECORD PLANS. NEC 220,215.5, | | | 240.4,230, 408.4ETC. THESE SECTIONS ARE GIVEN AS | | | GENERAL CHAPTERS AS PLANS ARE NOT COORDINATED. IT IS | | | NOT POSSIBLE TO DO A SPECIFIC REVIEW. | | | | | | 9) NOTE: THE BASE BUILDING ELECTRICAL RISER INDICATES A | | | MCCB YET THE EQUIPMENT RISER FROM MANUFACTURE DOES NOT | | | INDICATE THIS MCCB. THIS IS NOT ON THE RISER OR IN THE | | | LOAD CALCULATIONS. | | | 215.5,220,408.4,240.4, 310.16 ETC | | | NO INFORMATION IS PROVIDED FOR THIS PROVISION ON THE | | | BASE BUILDING PLANS. | | | FBC 106.1.1, 106.1.2, 106.3.5.1.2, COORDINATION AND | | | ADDITIONAL INFORMATION ON RECORD PLANS. SECTIONS ARE | | | GIVEN AS GENERAL CHAPTERS AS PLANS ARE NOT COORDINATED. | | | IT IS NOT POSSIBLE TO DO A SPECIFIC REVIEW. | | | | | | 10) NOTE: PLEASE KEEP IN MIND A COMPLETE REVISED | | | ELECTRICAL COORDINATION STUDY ALONG WITH TIME CURVES | | | ETC WILL BE REQUIRED NOT THAT ALL ELECTRICAL EQUIPMENT | | | IS NOTED, FIGURED ETC. | | | PLEASE SEE 240.12, 700.27, 701.8. | | | FBC 106.1.1, 106.1.2 FOR CLARITY, COORDINATION AND | | | INFORMATION ON THE RECORD PLANS. | | | | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2009-02-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-02-23 |
Time |
18:23 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-02-23 |
Time |
18:23 |
Sent To |
|
|
| Notes |
| 2009-02-23 18:24:35 | ** DENIED/ PASSED REVISIONS ** | | | | | | | | | | | | 1) NOTE: PLEASE SEE PROVISO ISSUED 12/17/08. ITEMS | | | NUMBERS 2, 4 AND 5 NEED TO BE REVISED AT THIS TIME. | | | THESE ARE NOT ITEMS FOR *AS BUILTS*. | | | FOR INFORMATION. | | | AS-BUILTS ARE PLANS MADE UP OF ALL REVISED PLANS ALONG | | | THE PROGRESS OF THE PROJECT. THE CITY OF WEST PALM | | | BEACH DOES REQUIRE REVISIONS HOWEVER NOT A FINAL SET OF | | | AS-BUILDS. | | | | | | 2) NOTE: THE POWER PLAN SHEET WAS OK, STAMPED. | | | | | | 3) NOTE: COMMENTS FROM PROVISO WITH RESPECT TO | | | CERTIFICATE OF AUTHORIZATION NUMBERS ON REQUIRED | | | PREVIOUS PLANS IS STILL IN EFFECT. THIS WILL BE | | | ADDRESSED WHEN SUBMITTING PLANS WHICH WERE NOT REVIEWED | | | AND STAMPED. THIS IS FOR EQUIPMENT MANUFACTURE PLANS | | | AND MANUFACTURES ELECTRICAL PLANS. | | | FS 471.023,FAC 61G15-23.002. REVIEW OF SAID DOCUMENTS | | | STILL NEEDS TO TAKE PLACE FOR CODE COMPLIANCE. | | | 110.3,90.7 ETC | | | | | | ** THIS REVIEW WILL REMAINED IN A FAILED STATUS EVEN AS | | | POWER PLAN SHEET E105 IS OK. | | | | | | | | | | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2008-12-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-12-17 |
Time |
11:44 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-12-17 |
Time |
11:44 |
Sent To |
|
|
| Notes |
| 2008-12-17 11:48:35 | ** PROVISO/REDLINED PLANS*** | | | | | | THE FOLLOWING ITEMS SHALL BE ADDRESSED AND SUBMITTED. | | | | | | 1) NOTE: ELECTRICAL MANUFACTURER'S SHOP DRAWINGS WILL | | | BE SUBMITTED AT LATER DATE ONCE CA # FROM STATE IS | | | OBTAINED. | | | FS471.023,FAC 61G15-23.002 | | | | | | | | | 2) NOTE: THE RISER STILL INDICATES * EQUIPMENT | | | GROUNDING CONDUCTORS* BEFORE THE FIRST MEANS OF | | | DISCONNECT FROM THE FPL TRANSFORMER WHICH IS NOT | | | PERMITTED. THIS HAS BEEN NOTED IN ALL OF THE THREE | | | PREVIOUS REVIEWS YET THE RISER NOTES HAVE NOT BEEN | | | CORRECTED. THE RESPONSE LETTER MENTIONS REVISIONS WERE | | | MADE HOWEVER THIS IS NOT THE CASE. | | | | | | 3) NOTE: PLEASE SEE THE SUBMITTED ELECTRICAL PLANS FOR | | | EQUIPMENT FROM ASSOCIATED ENGINEERS STILL DOES NOT HAVE | | | ALL INFORMATION ON TITLE BLOCKS COMPLETE. IN FACT THE | | | TITLE BLOCK WHERE THE REQUIRED CERTIFICATE OF | | | AUTHORIZATION NUMBER IS SUPPOSE TO BE STATES THE CA | | | NUMBER IS PENDING. THESE MAY NOT BE PART OF THE | | | SUBMITTED DOCUMENTS WITHOUT COMPLETE INFORMATION. THE | | | TITLE BLOCKS ARE REQUIRED TO CONTAIN THE PRINTED NAME | | | AND LICENSE NUMBER OF DESIGNER ALONG WITH THE | | | CERTIFICATE OF AUTHORIZATION NUMBER.\ | | | FAC 61G15-23.002, FS 471.023 | | | | | | | | | 4) NOTE: THE STAIRS FROM THE MEZZANINE LEVEL STILL DO | | | NOT INDICATE ANY LIGHTING MEETING EGRESS REQUIREMENTS. | | | THE RESPONSE AND PER PHONE CONVERSATION PREVIOUSLY | | | MENTIONED THIS WAS AND IS NOT AN EGRESS PATH REQUIRED | | | OR OTHER WISE. THIS IS A MEANS OF ESCAPE AS DEFINE IN | | | THE LIFE SAFETY CODE. | | | IN ORDER NOT TO BE PART OF ANY EGRESS PATH SIGNAGE FOR | | | DOOR MUST BE ON LIFE SAFETY PLANS AS WELL AS ELECTRICAL | | | PLANS. PLEASE SEE NFPA-101 | | | 7.10.8.3.1 ANY DOOR, PASSAGE, OR STAIRWAY THAT IS | | | NEITHER AN EXIT NOR A WAY OF EXIT ACCESS AND THAT IS | | | LOCATED OR ARRANGED SO THAT IT IS LIKELY TO BE MISTAKEN | | | FOR AN EXIT SHALL BE IDENTIFIED BY A SIGN THAT READS AS | | | FOLLOWS: | | | NO | | | EXIT | | | 7.10.8.3.2 THE NO EXIT SIGN SHALL HAVE THE WORD NO IN | | | LETTERS 51 MM (2 IN.) HIGH, WITH A STROKE WIDTH OF 9.5 | | | MM ( IN.), AND THE WORD EXIT IN LETTERS 25 MM (1 IN.) | | | HIGH, WITH THE WORD EXIT BELOW THE WORD NO, UNLESS SUCH | | | SIGN IS AN APPROVED EXISTING SIGN. | | | | | | ** THIS IS REQUIRED WHETHER OR NOT COMMENT IS MADE BY | | | ANY OTHER TRADE. | | | | | | | | | 5) NOTE: PLEASE CLARIFY JOCKEY PUMP WHICH RISER | | | INDICATES 30AMP DISCONNECT FUSED AT 30AMPS YET BRANCH | | | FROM ELP1 ONLY HAS 20AMP OCP WITH #12 CONDUCTORS.?? | | | 240.4,310.16, 430. | | | FBC 106.1.1 FOR CLARITY AND COORDINATION. | | | *** PRO | | | | | | *** NOTED SEPARATE PERMITS FOR LIGHTNING PROTECTION, | | | LOW VOLTAGE SYSTEMS, FIRE ALARM, FIRE SPRINKLER. THE | | | BASE PLANS MAY BE REFERENCED FOR LOW VOLTAGE SYSTEM | | | ONLY. SEPARATE PLANS WILL BE REQUIRED FOR LP, FS AND | | | FA. | | | THIS IS NOTED FOR REVIEW ONLY. NO RESPONSE OR CHANGES | | | ARE NEEDED ON PLANS OR SUBMITTED DOCUMENTS. | | | | | | | | | *** LETTER IN FILE WITH RESPECT TO BUILDING OCCUPANCY | | | WHEN UNDER EMERGENCY BACK UP POWER. IN COMPLIANCE WITH | | | FBC CHAPTER 10 AS WELL AS NFPA-101 THE BUILDING SHALL | | | BE EVACUATED WHEN NORMAL POWER IS LOST INCLUDING ALL | | | EMPLOYEEST. LETTER SUBMITTED SIGNED AND NOTARIZED FROM | | | MR. PATRICK CARROLL DIRECTOR OF FACILITIES DEVELOPMENT | | | IS IN FILE. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2008-12-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-12-15 |
Time |
11:43 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-12-12 |
Time |
17:10 |
Sent To |
|
|
| Notes |
| 2008-12-17 11:44:30 | ** DENIED 3RD REVIEW ** | | | | | | ** SOME ITEMS FROM PREVIOUS REVIEW ARE STILL IN NEED OF | | | ADDRESSING. | | | ** SOME OF THE ITEMS MAY BE ABLE TO BE SET UP AS PART | | | OF A PROVISO/ISSUANCE WITH CONDITIONS HOWEVER SOME MUST | | | BE ADDRESSED AT THIS TIME. | | | | | | 1) NOTE: PLEASE SEE THE SUBMITTED ENERGY CALCULATIONS | | | NEED TO BE SIGNED, DATED AND SEALED BY THE RESPONSIBLE | | | DESIGNER. THE CERTIFICATION SHEET CONTAINS A SIGNATURE | | | AND DATE HOWEVER NOT SEALED WITH THE RAISED SEAL. THIS | | | IS FOR BOTH THE MAIN FACILITY BUILDING AS WELL AND | | | SCALE HOUSE. | | | | | | 2) NOTE: PLEASE SEE THE CALCULATIONS FOR ELECTRICAL | | | LIGHTING APPEAR TO SHOW NO GROSS ERRORS AS NOTED IN FBC | | | 13-103.3. HOWEVER PLEASE SEE THE SCALE HOUSE | | | CALCULATIONS AS THESE MOST CERTAINLY COULD NOT BE | | | SIGNED AS COMPLIANT BY ELECTRICAL WHEN THERE ARE ITEMS | | | FOR OTHER TRADES LEFT COMPLETELY BLANK. | | | SOME OF THESE EXAMPLES WOULD BE THE IDR INDICATES: | | | NO WINDOWS YET THERE ARE WINDOWS ON THE BUILDING AND | | | FENESTRATIONS ARE ALSO BLANK. | | | NO DOORS, YET THERE ARE DOORS ON PLANS. | | | FLOORS FOR ALL AREAS NOTED AS CARPET AND RUBBER | | | PADDING. THIS IS NOT POSSIBLE. THERE ARE AREAS WITH | | | TILE AND OTHER SURFACES WHICH ARE NOT CARPET AND RUBBER | | | PADDING. | | | | | | ** THESE ITEMS ARE CLEAR TO THIS REVIEWER AS GROSS | | | ERRORS AND THESE CALCULATIONS COULD NOT BE STAMPED BY | | | ELECTRICAL AS CODE COMPLIANT WHETHER OR NOT THEY WERE | | | SIGNED AND SEALED. | | | ** THESE ITEMS NEED TO BE ADDRESSED WHETHER OR NOT | | | COMMENT IS MADE BY OTHER REVIEW STAFF. | | | | | | 13-400.A.3, 13-401, 13-403, 13-405 | | | | | | 3) NOTE: THE RISER STILL INDICATES * EQUIPMENT | | | GROUNDING CONDUCTORS* BEFORE THE FIRST MEANS OF | | | DISCONNECT FROM THE FPL TRANSFORMER WHICH IS NOT | | | PERMITTED. THIS HAS BEEN NOTED IN ALL OF THE THREE | | | PREVIOUS REVIEWS YET THE RISER NOTES HAVE NOT BEEN | | | CORRECTED. THE RESPONSE LETTER MENTIONS REVISIONS WERE | | | MADE HOWEVER THIS IS NOT THE CASE. | | | | | | 4) NOTE: PLEASE SEE THE SUBMITTED ELECTRICAL PLANS FOR | | | EQUIPMENT FROM ASSOCIATED ENGINEERS STILL DOES NOT HAVE | | | ALL INFORMATION ON TITLE BLOCKS COMPLETE. IN FACT THE | | | TITLE BLOCK WHERE THE REQUIRED CERTIFICATE OF | | | AUTHORIZATION NUMBER IS SUPPOSE TO BE STATES THE CA | | | NUMBER IS PENDING. THESE MAY NOT BE PART OF THE | | | SUBMITTED DOCUMENTS WITHOUT COMPLETE INFORMATION. THE | | | TITLE BLOCKS ARE REQUIRED TO CONTAIN THE PRINTED NAME | | | AND LICENSE NUMBER OF DESIGNER ALONG WITH THE | | | CERTIFICATE OF AUTHORIZATION NUMBER.\ | | | FAC 61G15-23.002, FS 471.023 | | | ***PRO | | | | | | 5) NOTE: THE STAIRS FROM THE MEZZANINE LEVEL STILL DO | | | NOT INDICATE ANY LIGHTING MEETING EGRESS REQUIREMENTS. | | | THE RESPONSE AND PER PHONE CONVERSATION PREVIOUSLY | | | MENTIONED THIS WAS AND IS NOT AN EGRESS PATH REQUIRED | | | OR OTHER WISE. THIS IS A MEANS OF ESCAPE AS DEFINE IN | | | THE LIFE SAFETY CODE. | | | IN ORDER NOT TO BE PART OF ANY EGRESS PATH SIGNAGE FOR | | | DOOR MUST BE ON LIFE SAFETY PLANS AS WELL AS ELECTRICAL | | | PLANS. PLEASE SEE NFPA-101 | | | 7.10.8.3.1 ANY DOOR, PASSAGE, OR STAIRWAY THAT IS | | | NEITHER AN EXIT NOR A WAY OF EXIT ACCESS AND THAT IS | | | LOCATED OR ARRANGED SO THAT IT IS LIKELY TO BE MISTAKEN | | | FOR AN EXIT SHALL BE IDENTIFIED BY A SIGN THAT READS AS | | | FOLLOWS: | | | NO | | | EXIT | | | 7.10.8.3.2 THE NO EXIT SIGN SHALL HAVE THE WORD NO IN | | | LETTERS 51 MM (2 IN.) HIGH, WITH A STROKE WIDTH OF 9.5 | | | MM ( IN.), AND THE WORD EXIT IN LETTERS 25 MM (1 IN.) | | | HIGH, WITH THE WORD EXIT BELOW THE WORD NO, UNLESS SUCH | | | SIGN IS AN APPROVED EXISTING SIGN. | | | | | | ** THIS IS REQUIRED WHETHER OR NOT COMMENT IS MADE BY | | | ANY OTHER TRADE. | | | *** PRO | | | | | | 6) NOTE: PLEASE CLARIFY JOCKEY PUMP WHICH RISER | | | INDICATES 30AMP DISCONNECT FUSED AT 30AMPS YET BRANCH | | | FROM ELP1 ONLY HAS 20AMP OCP WITH #12 CONDUCTORS.?? | | | 240.4,310.16, 430. | | | FBC 106.1.1 FOR CLARITY AND COORDINATION. | | | *** PRO | | | | | | 7) SEPARATE PERMITS FOR LIGHTNING PROTECTION, LOW | | | VOLTAGE SYSTEMS, FIRE ALARM, FIRE SPRINKLER. THE BASE | | | PLANS MAY BE REFERENCED FOR LOW VOLTAGE SYSTEM ONLY. | | | SEPARATE PLANS WILL BE REQUIRED FOR LP, FS AND FA. | | | THIS IS NOTED FOR REVIEW ONLY. NO RESPONSE OR CHANGES | | | ARE NEEDED ON PLANS OR SUBMITTED DOCUMENTS. | | | | | | | | | | | | | | | **IMPORTANT** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED | | | INTO TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | 2008-12-12 17:11:31 | REVIEW IS IN PROGRESS. | | | REVIEW WILL BE GOING INTO FAILED STATUS ONCE COMPLETED | | | AND NOTES WILL FOLLOW. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2008-10-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-10-27 |
Time |
16:49 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-10-27 |
Time |
16:49 |
Sent To |
|
|
| Notes |
| 2008-10-27 16:49:54 | | | | ** DENIED 2ND REVIEW** | | | | | | | | | 1) NOTE: PLEASE SEE THE LETTER SUBMITTED FOR THE | | | BUILDING NOT TO BE OCCUPIED UNDER THE LOSS OF | | | NORMAL/MAIN POWER IS TO BE REVISED. THE LETTER STATES | | | THE FACILITY WILL NOT OPERATE HOWEVER THE LETTER NEEDS | | | TO STATE THE BUILDING WILL NOT BE OCCUPIED BY ANY | | | PERSONNEL. THE LETTER(S) NEED TO BE ORIGINAL AND | | | NOTARIZED. PLEASE SEE FS 117.05 FOR NOTARIES. | | | NFPA-101 7.8, 7.9 | | | | | | 2) NOTE: THE PREVIOUS REVIEW REQUESTED THE REQUIRED | | | ENERGY CALCULATIONS TO BE SUBMITTED. AS THEY WERE NOT | | | SUBMITTED ON THE FIRST REVIEW THEY COULD NOT BE | | | REVIEWED. PLEASE SEE THE ENERGY CALCULATIONS AND THE | | | INPUT DATA REPORT NEED TO COORDINATE WITH THE PLANS. | | | THE INPUT DATA REPORT WILL BE NOTED BELOW AS IDR. | | | TWO SEPARATE CALCULATIONS WERE SUBMITTED. THE | | | *CERTIFICATIONS* SHEETS NEED TO BE COMPLETED WITH THE | | | SIGNATURE, DATE AND SEAL FROM THE RESPONSIBLE DESIGNER | | | OF RECORD. THE COVER SHEET WAS SIGNED AND SEALED. | | | EXAMPLES OF SOME INCONSISTENCIES OF THE SUBMITTED | | | CALCULATIONS AND THE IDR WILL BE NOTED. | | | | | | FOR EXAMPLE: PLEASE SEE THE SQUARE FOOTAGE OF THE | | | CALCULATION COVER SHEET SHOWS A TOTAL OF 7022 SQ FT | | | TOTAL OF CONDITIONED AND UNCONDITIONED SPACE. THIS IS | | | NOT POSSIBLE AS THE SQUARE FOOTAGE SHOWN ON A001CR1 | | | SHOWS NUMBERS FAR GREATER. THE SUBMITTED METHOD *A* IS | | | FOR WHOLE BUILDING. | | | | | | FOR EXAMPLE: PLEASE SEE THAT NOT ALL EXTERIOR LIGHTS ON | | | PLANS ARE IN THE IDR> ONE FIXTURE TYPE ALONE WOULD BE | | | THE S-7. THIS IS A 70W FIXTURE BASE DON THE FIXTURE | | | LEGEND AND THERE ARE NO 70W FIXTURES ON THE IDR FOR | | | EXTERIOR LIGHTING. ** THESE ARE NOT EXEMPT EVEN IF FOR | | | THE SIGN** PLEASE SEE THE FBC CHAPTER 13 IN ORDER TO | | | FALL UNDER EXCEPTIONS FOR THESE NOT TO BE | | | INCLUDED.13-415.2.ABC.1.3 | | | ** PLEASE SEE SHEET E123CR1 DOES NOT LIST THESE | | | FIXTURES AS PART OF THE CONTROLS EVEN AS THE SITE PLANS | | | CALL FOR SLP-25. | | | | | | FOR EXAMPLE: THE FIXTURE S2 IS A 400W FIXTURE HOWEVER | | | THE IDR SHOWS 800W. IT WAS ASSUMED THAT EACH POLE WHICH | | | CONTAINS TWO FIXTURES WERE COUNTED AS ONE AND THIS IS | | | WHY THE IDR SHOWS 800W WHICH ACCOUNTS FOR BOTH | | | FIXTURES. HOWEVER AS THE IDR SHOWS A TOTAL OF 6-800W | | | FIXTURES, WHAT ABOUT THE FIXTURES ON THE POLES WHICH | | | INDICATES ONLY ONE S2 FIXTURE? | | | THIS WAS NOT ACCOUNTED FOR IN THE IDR. | | | | | | FOR EXAMPLE: THE IDR INDICATES ALL * UNCOVERED PARKING | | | AREAS* AND THESE ASSOCIATED LIGHT FIXTURES. WHAT ABOUT | | | ALL OF THE OTHER FIXTURES WHICH ARE EXTERIOR FIXTURES | | | ON THE OUTSIDE OF THE BUILDING? BASED ON THE IDR, THE | | | LIGHTING PLANS AND THE FIXTURE LEGEND NONE OF THESE | | | FIXTURES WERE INCLUDED. | | | SEE E FIXTURE ALONE WHICH IS AN EXTERIOR WALL PACK. | | | | | | FOR EXAMPLE: PLEASE SEE THE INTERIOR LIGHT FIXTURES AS | | | THERE ARE SEVERAL FIXTURES ON THE PLANS WHICH ARE NOT | | | IN THE IDR. ONE OF THESE ALONE WOULD BE THE TYPE *A* | | | FIXTURE. | | | | | | ****** THESE ARE SOME EXAMPLES ONLY OF ITEMS ON THE | | | ELECTRICAL PLANS WHICH ARE NOT COORDINATED WITH THE IDR | | | AND THE SUBMITTED ENERGY CALCULATIONS. ALL AREAS, | | | TYPES, WATTAGES ETC NEED TO MEET THE MINIMUMS. | | | PLEASE SEE 13-415.2.ABC.1.1, .1.2 AND .1.3. | | | ******* | | | | | | 3) NOTE: PLEASE BE MORE SPECIFIC TO THE TYPE OF | | | OCCUPANCY SENSOR DEVICES. THE SYMBOL LEGEND DOES NOT | | | EXPAND ON DEVICES FOR AREAS SUCH AS EGRESS PATHS WHICH | | | ARE NOW ADDED TO PLANS. | | | PLEASE INDICATE THE FAIL SAFE OPERATION FOR THESE | | | DEVICES AS REQUIRED PER FBC 1006.1.2, NFPA-101 | | | 7.8.1.2.2 | | | DEVICES IN THE FIRE PUMP ROOM, MAIN ELECTRICAL ROOM AND | | | ELEVATOR EQUIPMENT ROOM ALSO NEED TO BE *FAIL SAFE ON* | | | OPERATION ON OCCUPANCY SENSING DEVICES. | | | PLEASE BE SURE THE SYMBOL LEGEND INDICATES THE TYPE AND | | | MAXIMUM TIME. | | | | | | 4) NOTE: PLEASE SEE THAT THE PREVIOUS REVIEW REQUESTED | | | INFORMATION ON THE FIRE PUMP, CONTROLLER ETC. THE | | | SUBMITTED PACKAGE DOES CONTAIN SHOP DRAWINGS/PRODUCT | | | APPROVALS WHICH DO CONTAIN THE INFORMATION HOWEVER SOME | | | OF THE SHEETS FOR THE FIRE PUMP ARE VERY FAINT AND NOT | | | READABLE. | | | PLEASE ALSO SHOW ON RISER, PLANS, SCHEDULE(S) WHERE AND | | | HOW THE JOCKEY PUMP IS BEING FED. COULD NOT LOCATE THIS | | | ON THE RISER ETC. SHEET E105CR1 INDICATES CIRCUITING TO | | | LP2, THIS IS A LIFE SAFETY SYSTEM, PLEASE EXPLAIN WHY | | | THIS IS NOT ON THE GENERATOR. | | | PLEASE SEE SAME SHEET E105CR1 WHICH DRAWING NOTE #44 | | | INDICATES A 10HP FIRE PUMP. THIS SEEMS TO BE A | | | MISPRINT? | | | PLEASE BE SURE TO SEE NFPA-20 CHAPTERS 6 AND 7 AND ALSO | | | SEE NFPA-70 695.6.C.1, 695.5 A, B. | | | | | | 5) NOTE: PLEASE SEE THE SHEET E120C WHICH STILL SHOWS | | | THE PREVIOUS RISER WHICH INDICATED THE NUMEROUS MAINS | | | AND OTHER ITEMS FROM PREVIOUS REVIEW WHICH HAVE NOW | | | BEEN REVISED. | | | PLEASE COORDINATE PLANS/SHEETS. | | | THE PREVIOUS NOTES GAVE SOME EXAMPLES OF COORDINATION | | | NEEDED. | | | EXAMPLE: PLEASE SEE E119C WHICH NOTES 3,4 AND 5 | | | INDICATE TWO PANELS AND A TRANSFORMER WHICH IS NOT ON | | | THE PRIMARY RISER SHEET. THERE ARE NO PANEL SCHEDULES | | | FOR THESE TWO PANELS ON THE SHEETS WITH THE OTHER PANEL | | | SCHEDULES AND THE 112.5 KVA TRANSFORMER IS NOT LISTED | | | ON EITHER OF THE TWO TRANSFORMER SCHEDULES ON SHEET | | | E107CR1 YET THIS IS NOTED ON SHEET E120C. PLEASE | | | EXPLAIN THE WORK SHOWN ON THESE OTHER SHEETS. ARE THESE | | | PERMITTED UNDER THIS SAME PERMIT OR SCOPE OF WORK? | | | NEC 230,240, 250, 215.5, 450ETC | | | FBC 106.1.1 FOR CLARITY AND COORDINATION OF PLANS. | | | | | | 6) NOTE: NEW NOTE: PLEASE EXPLAIN SUPPLEMENTAL LIGHTING | | | PLAN. | | | NEC 2005 | | | FBC 106.1.1 FOR ADDITIONAL INFORMATION/CLARITY | | | | | | 7) NOTE: PLEASE SEE 13-415.1.ABC.1.1,.1.2, AND .1.3. | | | THE OVER RIDES INDICATED ARE NOTED ON PLANS WITH NOTES | | | FOR LABELS AND PHONETIC LETTERING HOWEVER PLEASE SEE | | | SECTIONS NOTED. THE CODE REQUIRES THE OCCUPANT TO SEE | | | ALL LIGHTING WHICH IS BEING OVER RIDDEN OR MEET THE | | | EXCEPTION WHICH IS NOT ONLY DETAILED SIGNAGE FOR ALL | | | AREAS BEING OVER RIDDEN BUT ALSO FOR REQUIRED *PILOT | | | LIGHTS* OR * INDICATOR LIGHTS* OF SOME KIND. | | | | | | 8) NOTE: PLEASE SEE NFPA-101 7.8 AND 7.9 OF PREVIOUS | | | NOTES WITH RESPECT TO EGRESS LIGHTING LEVELS UNDER | | | NORMAL AND EMERGENCY CONDITIONS. | | | SOME LEVELS SHOWN ARE INDICATING LEVELS OF AVERAGE | | | BELOW THE 10FT CANDLES UNDER NORMAL CONDITIONS. THIS | | | LEVEL OF LIGHTING SHOULD BE FIGURED FROM THE STAIR | | | AREAS ONLY AND NOT FIGURING IN OTHER AREAS OF AVERAGE. | | | IF THERE ARE FIXTURES WHICH CONTRIBUTE TO THE LIGHTING | | | LEVELS THEN PLEASE CALL TO GO OVER CONTRIBUTIONS. THE | | | RESPONSE LETTER MENTIONS SOME STAIRS ARE NOT EGRESS | | | LOCATIONS USED FOR EXITING. | | | PLEASE SEE THE LIFE SAFETY CODE AS THE LIGHTING LEVEL | | | DOES APPLY TO EGRESS PATHS FOR ALL NOT ONLY THE GENERAL | | | PUBLIC. | | | PLEASE SEE NFPA-101 7.10.8.3,.3.1 AND .3.2 WHICH | | | REQUIRES SIGNAGE FOR ANY DOOR WHICH IS NOT AN EXIT DOOR | | | TO BE LABELED AS SUCH. PLEASE SEE SECTIONS FOR MINIMUM | | | SIZE AND WORDING. | | | | | | 9) NOTE: MSB ON SHEET E120C STILL INDICATES GFIC | | | PROTECTION. RESPONSE AND OTHER SHEETS WERE REVISED TO | | | GFP FOR PROTECTION OF MAIN SWITCH GEAR EQUIPMENT. | | | | | | 10) NOTE: PLEASE SEE THE RISER IS STILL SHOWING | | | EQUIPMENT GROUNDING FROM FPL TRANSFORMER TO THE FIRST | | | MEANS OF DISCONNECT WHICH IS NOT PERMITTED. THE | | | RESPONSE MENTION FIRE PUMP CALCULATIONS PROVIDED AND | | | THE MISINTERPRETATION OF THE CODE WITH RESPECT TO THE | | | EQUIPMENT GROUNDING CONDUCTOR. | | | 250.24C REQUIRES THE *GROUNDED* CONDUCTOR TO BE BROUGHT | | | TO THE FIRST MEANS OF DISCONNECT. AS THE CODE REQUIRES | | | BINDING OF THE GROUNDING CONDUCTOR AT THE FIRST MEANS | | | OF DISCONNECT IF AN *EQUIPMENT GROUNDING* CONDUCTOR IS | | | IN THE SAME CONDUIT THIS WOULD CREATE OBJECTIONABLE | | | CURRENTS PER 250.6. | | | ** PLEASE CALL TO GO OVER AS THERE MUST BE A LOSS IN | | | COMMUNICATION. | | | ** RESPONSE ALSO MENTIONS THE PLANS/RISER WAS REVISED | | | HOWEVER THE PLANS/RISER STILL INDICATES THE SAME. | | | | | | 11) NOTE: PLEASE SEE PREVIOUS NOTES WITH RESPECT TO | | | REQUIRED DEDICATED CIRCUITS FOR ELEVATOR EQUIPMENT | | | ROOMS. 645.23,22,24. | | | RESPONSE MENTIONS THE PLANS AND PANEL SCHEDULES HAVE | | | BEEN REVISED HOWEVER PLEASE SEE SHEET E105CR1. BASED ON | | | PLANS RECEPTACLES FED FROM RP2-35 ARE NOT MEETING THIS | | | REQUIREMENT. | | | | | | 12) NOTE: NEW NOTE: PLEASE PLACE NOTE ON PLANS FOR THE | | | *COMMUNICATION ROOM*. AS THIS IS NOT AN IT ROOM BY | | | DEFINITION IN NEC 645.2 PLEASE PLACE NOTE ON PLANS | | | WHICH STATES * NO WIRING METHODS FROM NEC 645 | | | PERMITTED* | | | | | | 13) NOTE: NOW THAT THE PLANS INDICATE THE GENERATOR | | | LOCATED OUTSIDE PLEASE SEE NFPA-110 CHAPTER 7 FOR THE | | | INSTALLATION REQUIREMENTS OF OUTDOOR UNITS. PLEASE | | | INDICATE THE ELEVATION MEETING THE SLOSH CHARTS/100 | | | YEAR FLOOD. 7.3 | | | | | | | | | | | | | | | | | | | | | | | | | | | **IMPORTANT** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED | | | INTO TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2008-07-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-07-30 |
Time |
16:29 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-07-30 |
Time |
16:29 |
Sent To |
|
|
| Notes |
| 2008-08-01 08:26:49 | ** NOTE ADDED | | | | | | | | | ** ALL CIRCUITING FOR EMEGENCY LIGHTING SHALL MEET | | | 700.12F. MANY LOCATIONS ON PLANS DO NOT MEET THE | | | EXCEPTIONS IN THE CODE. | | 2008-07-30 16:29:24 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | ** DENIEDAUDIT ** | | | | | | *** IT IS IMPORTANT TO KNOW THAT INFORMATION AND | | | DOCUMENTATION NOT SUBMITTED DOES NOT COMPLETE PACKAGE | | | FOR AUDIT AND DOES NOT PROVIDE THE MINIMUM REQUIRED BY | | | THE FLORIDA BUILDING CODE AND ALL OTHER APPLICABLE LAWS | | | AND ORDINANCES. | | | | | | 1) NOTE: *** PLEASE KNOW ALL PLANS AND DOCUMENTS WILL | | | BE RETAINED BY THIS OFFICE. PLANS AND SUPPORTING | | | DOCUMENTS MAY BE FORWARDED TO THE LICENSING BOARD FOR | | | BUILDING CODE ADMINISTRATORS AND INSPECTORS BOARD ALONG | | | WITH FLORIDA BOARD OF ENGINEERS FOR REVIEW OF SAID | | | PLANS AND DOCUMENTS. | | | | | | 2) NOTE: PLEASE SEE THERE ARE SEVERAL DOCUMENTS IN | | | PACKAGE SUBMITTED IN WHICH RAISED SEALS ARE PLACED OVER | | | PHOTO-COPIED SIGNATURES AND DATES. THIS IS NOT | | | PERMITTED UNDER FAC 61G15-23.002 AND FS 471.025. PLEASE | | | KNOW THIS SAME COMPANY IN WHICH MANY OF THESE DOCUMENTS | | | WERE DONE THIS MANOR HAS BEEN NOTIFIED ON PREVIOUS | | | PROJECTS THAT THIS IS NOT ACCEPTABLE UNDER FLORIDA LAW | | | HOWEVER THIS IS STILL BEING DONE. | | | | | | 3) NOTE:PLEASE PROVIDE AFFIDAVITS AS REQUIRED PER FS | | | 553.791 FOR EACH TRADE WHERE EACH AFFIDAVIT ACTUALLY | | | DOES LIST THE SHEETS. | | | PLACING ONE AND NOTING SEE ATTACHED IS NOT ACCEPTABLE. | | | | | | | | | 4 NOTE: PLEASE PROVIDE NOTICE TO BUILDING OFFICIAL AS | | | REQUIRED. FS553.791 | | | | | | 5) NOTE: PLEASE DO NOT SUBMIT REVISION TO THE STAMPED | | | PLANS WHEN THE | | | | | | 6) NOTE: PLEASE SUBMIT ENERGY CALCULATIONS/LIGHTING | | | PERFORMANCE CALCULATIONS PER 13-415.2.ABC.1.1, .1.2 AND | | | .1.3. | | | *** IT IS IMPORTANT TO KNOW THAT INFORMATION AND | | | DOCUMENTATION IS NOT COMPLETE. | | | | | | 7) NOTE: PLEASE KNOW THE LIGHTING PROTECTION SYSTEM | | | WILL BE REQUIRED TO BE UNDER SEPARATE PERMITS AND SHALL | | | CONTAIN NOTES AND DESIGN PER NFPA-780. | | | | | | 8) NOTE: AN AUDIT OF SIGNED, DATED AND SEALED | | | ELECTRICAL PLANS WAS NOT DONE AS NONE OF THESE CONTAIN | | | ANY STAMPS FROM THE PRIVATE PROVIDER. | | | FS 553.791 | | | | | | 9) NOTE: PLEASE SEE FBC 11-4.28.1,.2 AND .3. PLEASE | | | PROVIDE ALL MINIMUM LEVELS FOR FIRE ALARM DEVICES TO | | | MEET ADA REQUIREMENTS. PLEASE BE SURE TO STATE THE | | | LEVELS OF DEVICES. | | | | | | 10) NOTE: THE PLANS AND NOTES MENTIONS AUTOMATE | | | LIGHTING CONTROL SYSTEMS WITH CONTACTORS HOWEVER | | | COMPLETE DETAILS OF SYSTEMS, OVER RIDES, OVER RIDE | | | TIMES ETC ARE NOT LOCATED ON PLANS. | | | PLEASE SEE THERE ARE SEVERAL LOCATIONS INCLUDING | | | MEZZANINE LIGHTING WHICH DO NOT INDICATE ANY LIGHTING | | | CONTROLS FOR AUTOMATED SYSTEMS. THESE AREAS DO INDICATE | | | STANDARD SWITCHING DEVICES WHICH DO NO MEET | | | 13-415.1.ABC.1.1,.1.2, .1.3. | | | PLEASE ALSO SEE OTHER LOCATIONS ON E-112 | | | ** THIS IS NOT ALL LOCATIONS AS THERE ARE SEVERAL | | | SECTIONS ON PLANS WHICH DO NOT MEET MINIMUM CODE | | | | | | 11) NOTE: PLEASE PROVIDE COMPLETE INFORMATION ON | | | LIGHTING CONTROLS FOR EXTERIOR LIGHTING MEETING FBC | | | 13-415.1.ABC.1.4 | | | | | | 11) NOTE: PLEASE PROVIDE WORST CASE VOLTAGE DROP PER | | | 13-413.1.ABC.1.1, .1.2 | | | | | | 12) NOTE: PLEASE PROVIDE NOTES ON PLANS PER | | | 13-413.1.ABC.2.1,.2.2. | | | | | | 13) NOTE: PLEASE SEE SOME AREAS AS NOTED ON SHEET E102 | | | MENTION TO SEE E112, HOWEVER THESE SAME AREAS WHICH | | | MENTION TO SEE ENLARGED PLANS ARE NOT SHOWN. PLEASE SEE | | | SOME OF THESE AREAS ARE BREAK ROOM, BATHROOMS ETC WHICH | | | ARE NOT ON E112. | | | | | | 14) NOTE: PLEASE COMPLETE AND COORDINATE ALL SYMBOLS ON | | | PLANS. THIS INCLUDES ALL DEVICES SHOWN FOR LIGHTING | | | CONTROLS WHICH ARE NOT ON SYMBOL LEGEND. AN EXAMPLE OF | | | THIS IS SM. | | | FBC 13-415, NEC ALL | | | FBC 106.1.1 FOR CLARITY OF PLANS AND MINIMUM | | | INFORMATION. 106.3.5.1.2 | | | | | | 15) NOTE: PLEASE SUBMIT COMPLETE PHOTO-METRICS TO MEET | | | THE MINIMUM FOR LIFE SAFETY FOR ALL EGRESS PATHS. | | | PLEASE SEE SOME AREAS SUCH AS STAIRS INCLUDING THAT OF | | | EXTERIOR STAIRS DO NOT SHOW ANY BATTERY BACK UP | | | LIGHTING AS REQUIRED. | | | PLEASE SEE SECTIONS 7.8.1.3,7.9.2.1,79.2.2. | | | FAC 61G15-33.004 | | | ** EGRESS LIGHTING SHALL BE PROVIDED UNDER NORMAL AND | | | EMERGENCY CONDITIONS OUT OF THE BUILDING. PLEASE BE | | | SURE TO SEE THE LEVELS DID INCREASE UNDER THE 2003 | | | NFPA-101 | | | | | | 16) NOTE: PLEASE BE SURE THE FOLLOWING CODES ARE STATED | | | ON ELECTRICAL PLANS AT A MINIMUM FOR THIS TRADE. FBC | | | 2004 W/2007 REVISIONS. | | | 2003 NFPA-101 | | | 2005 NFPA-70 | | | 2002 NFPA-72 | | | 2003 NFPA-20 | | | 2002 NFPA-110 | | | | | | 17) NOTE: PLEASE COMPLETE ALL INFORMATION ON PLANS FOR | | | FIRE PUMP, FIRE PUMP CONTROLLER. PLEASE KNOW AS THE | | | INFORMATION ON THE FP IS NOT COMPLETE PLEASE SUBMIT | | | COMPLETE PLANS FOR MINIMUM. PLEASE KNOW THAT CHAPTERS | | | OF THEN CODES WILL BE CITED NOT SECTIONS AS THERE TOO | | | MANY SECTIONS OF THE CODE MISSING. | | | PLEASE INDICATE LOCK ROTOR MAXIMUM OVER CURRENT | | | PROTECTION. | | | PLEASE SEE NFPA-70 695.4B1 (1) OVER-CURRENT DEVICE | | | SELECTION THE OVER-CURRENT PROTECTIVE DEVICE(S) SHALL | | | BE SELECTED OR SET TO CARRY INDEFINITELY THE SUM OF THE | | | LOCKED-ROTOR CURRENT OF THE FIRE PUMP MOTOR(S) AND THE | | | PRESSURE MAINTENANCE PUMP MOTOR(S) AND THE FULL-LOAD | | | CURRENT OF THE ASSOCIATED FIRE PUMP ACCESSORY EQUIPMENT | | | WHEN CONNECTED TO THIS POWER SUPPLY. THE REQUIREMENT TO | | | CARRY THE LOCKED-ROTOR CURRENTS INDEFINITELY SHALL NOT | | | APPLY TO CONDUCTORS OR DEVICES OTHER THAN OVER-CURRENT | | | DEVICES IN THE FIRE PUMP MOTOR CIRCUIT(S). | | | | | | PLEASE SEE NFPA-20 CHAPTERS 9, 10 ETC | | | PLEASE SUBMIT MANUFACTURES SPEC/CUT SHEETS FOR THE FIRE | | | PUMP AND FIRE PUMP CONTROLLER. | | | 110.3,90.7, NFPA-20. | | | ** AS PLANS AND INFORMATION IS NOT COMPLETE MANY ITEMS | | | FOR MINIMUM CODE COMPLIANCE CAN NOT BE DETERMINED AT | | | THIS TIME. | | | | | | 18) NOTE: PLEASE SEE 230.2 AS THE NUMBER OF SERVICES | | | SHOWN ON PLANS ARE NOT PERMITTED AND NOT ALL MEET THE | | | EXCEPTIONS IN THE CODE AT THIS TIME. | | | PLEASE LOOK AT RISER AS THE EQUIPMENT FED FROM MSB ARE | | | BEING NOTED AS *MAINS*. | | | | | | 19) NOTE: PLEASE SEE 230.95, 240.13 AS THE 3000AMP MAIN | | | INDICATE GFIC PROTECTION. SHOULD THIS NOT BE GFP FOR | | | GROUND FAULT PROTECTION? GFCI IS FOR PERSONNEL. | | | | | | 20) NOTE: PLEASE SUBMIT AND SHOW A COMPLETE GROUNDING | | | ELECTRODE RISER FOR ALL TRANSFORMERS AND COMMON | | | SYSTEM. | | | 250.58, 250.66 | | | | | | 21) NOTE: PLEASE SEE THERE ARE LOCATIONS WHERE | | | EQUIPMENT GROUNDING CONDUCTORS ARE BEING SHOWN BEFORE | | | THE FIRST MEANS OF DISCONNECT WHICH IS NOT PERMITTED. | | | PLEASE CLARIFY THE #4 TO FIRE PUMP CONTROLLER. PLEASE | | | BE SURE TO SIZE THE NEUTRAL (GROUNDED CONDUCTOR) AS | | | THIS IS REQUIRED TO CONTAIN A NEUTRAL TO THE FIRST | | | MEANS OF DISCONNECT. IN NO CASE MAY THIS BE SMALLER | | | THAN THE GROUNDING ELECTRODE | | | CONDUCTOR.250.4,250.6,250.50,ETC | | | THIS IS ALSO NOTED FOR THE 3000AMP MAIN AS AN EQUIPMENT | | | GROUNDING CONDUCTOR IS ALSO SHOWN BEFORE THE FIRST | | | MEANS OF DISCONNECT WHICH IS NOT PERMITTED. THIS | | | CREATES OBJECTIONABLE CURRENTS. | | | | | | 22) NOTE: PLEASE SEE 230.95, 240.13, 700.7D, 700.26, | | | NFPA-110 6.2.1.5 | | | AS THE TRANSFER SWITCH ON PLANS DOES NOT INDICATE HOW | | | MANY POLES. BASED ON THE CODE SECTIONS GIVEN THIS IS | | | REQUIRED TO BE A FOUR POLE UNIT. THE FOLLOWING TEXT MAY | | | BE OF USE FOR THE TRANSFER SWITCH. THIS WORDING IS FROM | | | ONE WHITE PAPER FROM ONE MANUFACTURE AND THERE ARE | | | SEVERAL OTHERS AVAILABLE. | | | | | | *WHERE GROUND FAULT PROTECTION IS TRIGGERED BY THE CODE | | | AND AN ALTERNATE POWER SUPPLY IS INCLUDED, SWITCHING OF | | | THE NEUTRAL BECOMES NECESSARY. THE CIRCUIT SHOWN ABOVE | | | ILLUSTRATES SUCH A CIRCUMSTANCE. | | | THE SERVICE IS LARGER THAN 1,000 AMPS. CONSEQUENTLY, | | | GROUND FAULT PROTECTION IS REQUIRED AT THE MAIN SERVICE | | | DISCONNECT AT A MINIMUM. IF IT IS INSTALLED THERE AND | | | THE GENERATOR NEUTRAL GROUNDING WAS THROUGH A SOLID | | | CONNECTION TO THE MAIN SERVICE NEUTRAL, A GROUND FAULT | | | WHEN THE GENERATOR IS FEEDING | | | THE LOAD WILL CAUSE THE MAIN SERVICE DISCONNECT TO | | | OPEN. THIS WILL NOT DISCONNECT THE ARCING FAULT FROM | | | THE GENERATOR. COORDINATION IS THUS LOST.* | | | | | | THIS WAS FROM ASCO WHITE PAPER PAGE #5. OTHERS SUCH AS | | | CATERPILLAR ETC HAVE MUCH OF THE SAME. | | | | | | | | | 23) NOTE: PLEASE SEE NFPA-110 9.6.2.2 AND INDICATE THE | | | MINIMUM TIMES FOR ON-SITE FUEL AS REQUIRED FOR POWER | | | FOR FIRE PUMP ALONG WITH OTHER EMERGENCY LOADS. 9.6.2.2 | | | THE FUEL SUPPLY CAPACITY SHALL BE SUFFICIENT TO PROVIDE | | | 8 HOURS OF FIRE PUMP OPERATION AT 100 PERCENT OF THE | | | RATED PUMP CAPACITY IN ADDITION TO THE SUPPLY REQUIRED | | | FOR OTHER DEMANDS. | | | | | | | | | 24) NOTE: PLEASE KNOW BATTERY BACK UP LIGHTING SHALL BE | | | REQUIRED FOR THE EGRESS LIGHTING PATHS PER NFPA-7.8, | | | 7.9.PLEASE KNOW THIS BUILDING SHALL NOT RELY ON THE | | | SINGLE TRIPPING OF A BREAKER, SWITCHING OF A DEVICE TO | | | LEAVE ANY ONE ARE IN TOTAL DARKNESS. | | | PLEASE BE SURE OTHER LOCATIONS SUCH AS THE MAIN | | | ELECTRICAL ROOM, FIRE PUMP ROOM, ELEVATOR EQUIPMENT | | | ROOM ALSO CONTAIN BATTERY BACK UP LIGHTING. | | | | | | 25) NOTE: PLEASE SUBMIT THE PLANS WITH THE COMPLETED | | | INFORMATION FOR LOCATION OF THE GENERATOR. THE RISER | | | SHOWS A GENERATOR HOWEVER WHERE IS THIS UNIT GOING TO | | | BE INSTALLED? PLEASE SEE OTHER PLANS SUCH AS SITE, | | | MECHANICAL, BUILDING ETC DO NOT SHOW ANY LOCATIONS. | | | | | | 26) NOTE: PLEASE SEE NEC 645.,23AS THE MINIMUM | | | REQUIRED DEDICATED CIRCUITS ARE NOT LOCATED ON PLANS. | | | IN FACT ONE EXAMPLE OF NON-COMPLIANCE IS THE FACT THE | | | LIGHTING IN THE MACHINE ROOM WHICH IS REQUIRED TO BE ON | | | A DEDICATED CIRCUIT PER 620.23 IS SHOWN CIRCUITED TO | | | OTHER NORMAL LIGHTING OUTSIDE OF THIS ROOM. | | | PANEL SCHEDULE INDICATES OTHERS PER 620.22, 620.24 | | | HOWEVER PLANS DO NOT SHOW SOME OF THESE CIRCUITS, | | | LIGHTS, PIT LIGHTING, GFI RECEPTACLES ETC. RECEPT SHOWN | | | HOWEVER SECTIONS AS NOTED REQUIRE GFCI PROTECTION. THIS | | | IS NO ON PLANS OR ON PANEL SCHEDULE | | | IF THE PANEL SCHEDULE ONLY INDICATES *RECEPTACLES FOR | | | EXAMPLE ON RP1-16 THE DEDICATE CIRCUIT IS NOT | | | DETERMINED | | | | | | | | | 27) NOTE: PLEASE SEE NFPA-110 CHAPTER 7, 7.3.3 AS THE | | | MINIMUM LIGHTING IN ANY GENERATOR ROOM SHALL MEET THIS | | | MINIMUM. | | | PLEASE KEEP IN MIND AS THE GENERATOR IS NOT SHOWN THIS | | | IS GIVEN FOR INFORMATION ONLY. | | | PLEASE SEE THE FOLLOWING FOR LOCATION AS THIS WAS NOT | | | SHOWN AT THIS TIME. | | | | | | 7.2 LOCATION. | | | 7.2.1 THE EPS SHALL BE INSTALLED IN A SEPARATE ROOM FOR | | | LEVEL 1 INSTALLATIONS. EPSS EQUIPMENT SHALL BE | | | PERMITTED TO BE INSTALLED IN THIS ROOM. | | | 7.2.1.1 THE ROOM SHALL HAVE A MINIMUM 2-HOUR FIRE | | | RATING OR BE LOCATED IN AN ADEQUATE ENCLOSURE LOCATED | | | OUTSIDE THE BUILDING CAPABLE OF RESISTING THE ENTRANCE | | | OF SNOW OR RAIN AT A MAXIMUM WIND VELOCITY REQUIRED BY | | | LOCAL BUILDING CODES. | | | 7.2.1.2 NO OTHER EQUIPMENT, INCLUDING ARCHITECTURAL | | | APPURTENANCES, EXCEPT THOSE THAT SERVE THIS SPACE, | | | SHALL BE PERMITTED IN THIS ROOM. | | | 7.2.2 EPSS EQUIPMENT SHALL NOT BE INSTALLED IN THE SAME | | | ROOM WHERE THE NORMAL ELECTRICAL SERVICE EQUIPMENT IS | | | INSTALLED. | | | 7.2.2.1 TRANSFER SWITCHES SHALL BE PERMITTED TO BE | | | INSTALLED IN THE NORMAL ELECTRICAL SERVICE ROOM WHERE | | | TWICE THE CLEARANCE REQUIRED BY ARTICLE 110.26(A) OF | | | NFPA 70, NATIONAL ELECTRICAL CODE, EXISTS BETWEEN | | | EQUIPMENT ENCLOSURES. | | | 7.2.3*THE ROOMS, SHELTERS, OR SEPARATE BUILDINGS | | | HOUSING LEVEL 1 OR LEVEL 2 EPSS EQUIPMENT SHALL BE | | | DESIGNED AND LOCATED TO MINIMIZE THE DAMAGE FROM | | | FLOODING, INCLUDING THAT CAUSED BY THE FOLLOWING: (1) | | | FLOODING RESULTING FROM FIRE FIGHTING | | | (2)SEWER WATER BACKUP | | | (3)SIMILAR DISASTERS OR OCCURRENCES | | | 7.2.4*MINIMIZING THE POSSIBILITY OF DAMAGE RESULTING | | | FROM INTERRUPTIONS OF THE EMERGENCY SOURCE SHALL BE A | | | DESIGN CONSIDERATION FOR LEVEL 1 AND LEVEL 2 EPSS | | | EQUIPMENT. | | | 7.2.5 THE EPS EQUIPMENT SHALL BE INSTALLED IN A | | | LOCATION THAT PERMITS READY ACCESSIBILITY AND A MINIMUM | | | OF 76 CM (30 IN.) FROM THE SKID RAILS' OUTERMOST POINT | | | IN THE DIRECTION OF ACCESS FOR INSPECTION, REPAIR, | | | MAINTENANCE, CLEANING, OR REPLACEMENT. THIS REQUIREMENT | | | SHALL NOT APPLY TO UNITS IN OUTDOOR HOUSINGS. | | | | | | 28) NOTE: PLEASE SEE 450.3 AS THE MAXIMUM OVER CURRENT | | | PROTECTION ON THE TRANSFORMER TRP1 SHALL BE 125% UNLESS | | | MEETING EXCEPTIONS. AS THE PLANS DO NOT INDICATE WHAT | | | TYPE OF UNIT THIS IS PLEASE SEE SECTION AS NOTED. | | | | | | 29) NOTE: PLEASE SEE 408.4 AS THE CIRCUITS SHOWN ON | | | PANEL SCHEDULES SHALL BE SPECIFIC TO ROOMS AND AREAS IN | | | WHICH THEY FEED. STATING *RECEPTACLES* OR *LIGHTING* IS | | | NOT ACCEPTABLE. PLEASE KNOW A NUMERICAL OR ALPHA | | | DESIGNATION MAY BE USED. | | | | | | 30) NOTE: PLEASE INCLUDE FOOTER STEEL AS PART OF THE | | | GROUNDING ELECTRODE SYSTEM AS REQUIRED PER 250.50. | | | | | | 31) NOTE: PLEASE SEE RISER AS ERP1 INDICATES A FEED TO | | | PANEL ERPSH HOWEVER THE PANEL SCHEDULE FOR ERP1 DOES | | | NOT INDICATE ANY SUB FEED FOR PANEL ERPSH. | | | PLEASE COMPLETE WITH OCP, CONDUCTORS, LOADS ETC. | | | 408.4,310.16,240.4,220,ETC | | | | | | 32) NOTE: PLEASE SUBMIT AND SHOW COMPLETE LOAD | | | CALCULATIONS PER NEC 220. | | | PLEASE BE SURE ALL CONTINUOUS LOADS ALONG WITH LARGEST | | | MOTOR LOADS ARE FIGURED SHOWN AT 125%. | | | PLEASE BE SURE THE WATER HEATER LOADS ARE FIGURED AND | | | SHOWN AT 125%. 220,12,220.14,220.42,,220.44,220.50, ETC | | | 215.3,230.42, 422.13 FOR CONTINUOUS LOADS. | | | FBC 106.1.1, 106.3.5.1.2 FOR CLARITY AND MINIMUM | | | REQUIRED ON PLANS. | | | | | | 33) NOTE: PLEASE SEER RISER AS LPSH INDICATES A FEED TO | | | PANEL RPSH YET THERE IS NO BREAKER, LOAD, CIRCUIT | | | LISTED ON PANEL LPSH FOR THIS NEW PANEL. | | | PLEASE COMPLETE. | | | 240.4,220,310.16 ETC | | | | | | 34) NOTE: PLEASE PROVIDE GROUNDING ELECTRODE | | | RISER/DIAGRAM FOR SCALE HOUSE PER | | | 250.50,250.30,250.32. | | | | | | 35) NOTE: PLEASE SEE THE RISER SHOWS THE TRANSFORMER AT | | | THE SCALE HOUSE AS TRP-SH WHICH BY THE TRANSFORMER | | | CALLS FOR THIS UNIT AS A 30KVA UNIT YET THE LEGEND AND | | | PLANS ON SHEET E-112 INDICATES THIS SAME UNIT AT THE | | | SCALE HOUSE IS SHOWN AS 15KVA. | | | PLEASE KNOW AS BOTH UNITS ARE SHOWN WITH TWO DIFFERENT | | | SIZES THE OVER CURRENT PROTECTION ETC CAN NOT BE | | | DETERMINED AS CODE COMPLIANT. | | | PLEASE COORDINATE | | | 450.3, 240.21, 310.16, 240.4 ETC. | | | | | | 36) NOTE: PLEASE SEE MAIN ELECTRICAL ROOM PART ROOM | | | PLAN WHICH INDICATES ANOTHER 15KVA TRANSFORMER YET THE | | | ELECTRICAL TRANSFORMER LEGEND ON SHEET ON E-107 DOES | | | NOT INDICATE ANY 15K TRANSFORMERS. AS THESE DOE NOT | | | COORDINATE DETERMINATION FOR CODE COMPLIANCE CAN NOT BE | | | DONE. | | | 240.21,450.3,310.16 ETC | | | FBC 106.1.1 FOR COORDINATION AND CLARITY OF PLANS. | | | | | | 37) NOTE: PLEASE SUBMIT THE MANUFACTURES SPECS/CUT | | | SHEETS ON THE ATS, GENERATOR, AS NOTED ABOVE FOR OTHER | | | EQUIPMENT. 110.3,90.7 | | | | | | | | | ** PLEASE KNOW AS THERE IS INFORMATION AND | | | DOCUMENTATION NOT YET SUBMITTED FOR AUDIT THERE MAY | | | VERY WELL BE NEW COMMENTS ON THE FOLLOWING AUDIT WHICH | | | CAN NOT BE MADE AT THIS TIME. | | | | | | ** IF THERE ARE ANY QUESTIONS OR IF THE COMMENTS ARE | | | NOT CLEAR IN ANY MANOR PLEASE DO NOT HESITATE IN | | | CONTACTING THIS OFFICE. | | | | | | | | | IMPORTANT** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | | TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
4 |
Status |
P |
Date |
2008-11-19 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2008-11-19 |
Time |
10:55 |
Rev Time |
1.00 |
| Received By |
mgonzale |
Date |
2008-11-19 |
Time |
10:54 |
Sent To |
|
|
| Notes |
| 2008-11-19 10:55:03 | - PASSED - | | | | | | ENGINEER HAS COMPLIED WITH ALL REQUESTS SET FORTH BY | | | THE ENGINEERING DEPT. | | | | | | MANUEL J GONZALEZ, PROJECT COORDINATOR (561) 494-1040 | | | LOCATION ADDRESS: | | | CITY OF WEST PALM BEACH | | | ENGINEERING SERVICES DEPARTMENT | | | 1000 - 45TH STREET, SUITE 15 | | | WEST PALM BEACH FL 33407 | | | CITY'S WEB SITEHAS ALL OUR REFERENCE MATERIAL YOU NEED | | | TO COMPLY: | | | FEEL FREE TO SEE THE LINKS BELOW: | | | WWW.CITYOFWPB.ORG | | | | | | MAILING ADDRESS: | | | CITY OF WEST PALM BEACH | | | ENGINEERING SERVICES DEPARTMENT | | | P.O. BOX 3506 | | | WEST PALM BEACH FL 33401 | | | TELEPHONE: | | | 45TH STREET OFFICE : 561-494-1040 | | | 45TH DIRECT: 561-494-1085 | | | FAX: 561-494-1117 | | | CITY HALL OFFICE: (561) 805-6723 | | | CITY HALL DIRECT: (561) 805-6327 | | | CITY HALL FAX: (561) 805-6731 OR 805-6676 | | | NEXTEL: 561-644-7301 | | | NEXTEL DIRECT CONNECT: 159*28165*38 | | | EMERGENCIES: | | | CENTRAL OPERATIONS CENTER (DISPATCH) 561-822-2210 | | | E-MAIL: | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
P |
Date |
2008-11-05 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2008-11-05 |
Time |
12:43 |
Rev Time |
1.00 |
| Received By |
mgonzale |
Date |
2008-11-05 |
Time |
|
Sent To |
ENG |
|
| Notes |
| 2008-11-05 12:42:56 | ENGINEER HAS POMPLIED WITH ALL REQUESTS SET FORTH BY | | | THE ENGINEERING DEPT. INCLUDES WATER, SEWER AND STORM | | | ISSUES. | | | MANNY GONZALEZ, PROJECT COORDINATOR | | | CITY OF WPB ENGINEERING (561) 494-1085 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
F |
Date |
2008-09-23 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2008-09-23 |
Time |
10:46 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2008-09-23 |
Time |
10:41 |
Sent To |
|
|
| Notes |
| 2008-09-23 10:46:04 | FAILED FOR FOLLOWING REASONS: | | | | | | 1. PLEASE SHOW ON DRAWINGS THE SILT FENCE DETAILS & | | | TURBIDITY DETAILS OF POLLUTION PREVENTION . PLEASE SHOW | | | ON DRAWINGS THE SILT FENCE AROUND THE WHOLE SITE, & | | | TURBIDITY AROUND CATCH BASINS DURING CONSTRUCTION AND | | | ALL DEMOLITION PHASE. HEIGHT OF FENCE SHOULD BE HIGH | | | ENOUGH PER FDEP TO STOP DUST PARTICLES. | | | | | | 2. PLEASE PROVIDE A COPY OF BOND FOR ORDINANCE NO. | | | 4060-07: | | | | | | ALL DEMOLITION AND NEW CONSTRUCTION PERMITS, WITH | | | EXCEPTION OF SINGLE FAMILY, DUPLEX AND ACCESSORY | | | APARTMENT, SHALL POST BONDS OR DEPOSITS FOR THE | | | FOLLOWING: | | | | | | 1. EROSION CONTROL, AND | | | 2. LAND STABILIZATION | | | | | | THE AMOUNT OF THE EROSION CONTROL AND LAND | | | STABILIZATION BONDS SHALL BE DETERMINED BY THE ENGINEER | | | OF RECORD USING THE CURRENT CITY COST SCHEDULE AND | | | VERIFIED BY THE CITY'S ENGINEERING SERVICES DEPT. | | | PLEASE CONTACT BRIAN MOREE, ENG SERVICES CONSTRUCTION | | | SUPERVISOR, AT 561- 494 -1040 FOR MORE INFORMATION. | | | | | | UPON VERTICAL CONSTRUCTION COMMENCEMENT, PAYMENT IN | | | FULL OF ALL APPLICABLE FEES, AND COMPLIANCE WITH ALL | | | TERMS AND CONDITIONS OF ANY POSTED BOND, THE PERMITTEE | | | MAY REQUEST RELEASE OF THE BONDS OR DEPOSITS. | | | | | | A COPY OF ORDINANCE NO. 4060-07 MAY BE OBTAINED FROM | | | THE CITY CLERK'S OFFICE LOCATED ON THE FIRST FLOOR. | | | | | | 3. PLEASE SHOW ON DRAWING ALL CITY STANDARDS NOTES FOR | | | SIDEWALK, DRIVEWAY, APPROACH, PARKINGS, HANDICAP | | | PARKINGS, DUMPSTER ENCLOSURE, YOU CAN GET A C D FOR ALL | | | CITY STANDARDS NOTES FROM 1000, 45 STREET, ENGINEERING | | | SERVICES, PHONE# 494-1040 | | | | | | 4. PLEASE SHOW ON DRAWINGS DUMPSTER & ITS ENCLOSURE | | | DETAILS PER CITY OF WPB, & LOCATION ON DWG, LOCATION | | | MUST BE ACCESSIBLE FOR PICKUP TRUCK. | | | | | | 5. PLEASE SHOW ON DRAINAGE DRAWING THE SITE AREA, | | | GREEN, LAKE,PARKING AREA, IMPERVIOUS,PERVIOUS AREA YOU | | | ARE DEVELOPING FOR THIS PROJECT . PLEASE MAKE SURE | | | THESE AREAS SHOWN ON DRAINAGE DRAWINGS MUST MATCH WITH | | | AND USED IN STORM WATER QUALITY CALCULATIONS. PLEASE | | | PROVIDE A COPY OF THESE CALCULATIONS. | | | | | | | | | PLEASE RESPOND EACH ITEM IN DETAIL TO EXPEDITE YOUR | | | PERMITTING PROCESS | | | | | | RASIK CHOKSHI 805-6723 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2008-07-24 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2008-07-24 |
Time |
11:08 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2008-07-24 |
Time |
11:04 |
Sent To |
|
|
| Notes |
| 2008-07-24 11:08:18 | FAILED FOR FOLLOWING REASONS: | | | | | | 1. PLEASE PROVIDE A COPY OF NOTICE OF INTENT (NOI). | | | PLEASE APPLY AT FDEP, NPDES STORMWATER SECTION FOR | | | NOI. | | | YOU CAN GET NOI INFO FROM | | | WWW.DEP.STATE.FL.US/WATER/STORMWATER/NPDES/ | | | NOTICE OF INTENT DEP FORM 62-621.300(4)(B), | | | EFFECTIVE MAY 1, 2003 | | | | | | 2. PLEASE SHOW ON DRAWINGS THE SILT FENCE DETAILS & | | | TURBIDITY DETAILS OFPOLLUTION PREVENTION . PLEASE | | | SHOW ON DRAWINGS THE SILT FENCE AROUND THE WHOLE SITE, | | | & TURBIDITY AROUND CATCH BASINS DURING CONSTRUCTION AND | | | ALL DEMOLITION PHASE.HEIGHT OF FENCE SHOULD BE HIGH | | | ENOUGH PER FDEP TO STOP DUST PARTICLES. | | | | | | 3. PLEASE PROVIDE A COPY OF BOND FOR ORDINANCE NO. | | | 4060-07: | | | | | | ALL DEMOLITION AND NEW CONSTRUCTION PERMITS, WITH | | | EXCEPTION OF SINGLE FAMILY, DUPLEX AND ACCESSORY | | | APARTMENT, SHALL POST BONDS OR DEPOSITS FOR THE | | | FOLLOWING: | | | | | | 1. EROSION CONTROL, AND | | | 2. LAND STABILIZATION | | | | | | THE AMOUNT OF THE EROSION CONTROL AND LAND | | | STABILIZATION BONDS SHALL BE DETERMINED BY THE ENGINEER | | | OF RECORD USING THE CURRENT CITY COST SCHEDULE AND | | | VERIFIED BY THE CITY'S ENGINEERING SERVICES DEPT. | | | PLEASE CONTACT BRIAN MOREE, ENG SERVICES CONSTRUCTION | | | SUPERVISOR, AT 561- 494 -1040 FOR MORE INFORMATION. | | | | | | UPON VERTICAL CONSTRUCTION COMMENCEMENT, PAYMENT IN | | | FULL OF ALL APPLICABLE FEES, AND COMPLIANCE WITH ALL | | | TERMS AND CONDITIONS OF ANY POSTED BOND, THE PERMITTEE | | | MAY REQUEST RELEASE OF THE BONDS OR DEPOSITS. | | | | | | A COPY OF ORDINANCE NO. 4060-07 MAY BE OBTAINED FROM | | | THE CITY CLERK'S OFFICE LOCATED ON THE FIRST FLOOR. | | | | | | 4. PLEASE SHOW ON DRAWING ALL CITY STANDARDS NOTES FOR | | | SIDEWALK, DRIVEWAY, APPROACH, PARKINGS, HANDICAP | | | PARKINGS, DUMPSTER ENCLOSURE, YOU CAN GET A C D FOR ALL | | | CITY STANDARDS NOTES FROM 1000, 45 STREET, ENGINEERING | | | SERVICES, PHONE# 494-1040 | | | | | | 5. PLEASE SHOW ON DRAWINGSDUMPSTER & ITS ENCLOSURE | | | DETAILS PER CITY OF WPB, &LOCATION ON DWG, LOCATION | | | MUST BE ACCESSIBLE FOR PICKUP TRUCK. | | | | | | 6. PLEASE SHOW ON CALCULATION THAT YOU HAVE CONSIDERED | | | FLOOD ZONE AREA, & 5,10, 25, 100 YEAR FLOOD CRITERIA | | | AND CROWN OF THE ROAD WHEN YOU DETERMINE THE FIRST | | | FLOOR ELEVATION. FIRST FLOOR ELEVATION SHOULD BE | | | ATLEAST 1 FOOT HIGHER THAN HIGHEST CROWN OF THE ROAD. | | | STORM WATER CALS APPROVED PER DEAN L'S E-MAILPERMIT# | | | 08050249 | | | | | | 7. PLEASE SHOW ON DRAINAGE DRAWINGTHE SITE AREA, | | | GREEN, LAKE,PARKING AREA, IMPERVIOUS,PERVIOUS AREAYOU | | | ARE DEVELOPING FOR THIS PROJECT . PLEASEMAKE SURE | | | THESE AREAS SHOWN ON DRAINAGE DRAWINGS MUST MATCH WITH | | | AND USED IN STORM WATER QUALITY CALCULATIONS. PLEASE | | | PROVIDE A COPY OF THESE CALCULATIONS. | | | | | | 8. PLEASE SHOW ALL STORM WATER PIPES AROUND YOUR SITE | | | SO, WE CANSEE THE LAYOUT OF STORM WATER PIPES FROM | | | ALL OTHER STORM WATER PIPES. PLEASE SHOW DETAIL OF THE | | | CONTROL STRUCTURESWITH ELEVATIONS, NOTCHES, BLEEDING | | | ELEVATION, ETC ON DRAWINGS, CALCULATION FOR | | | EXFILTRATION TRENCHES, PLEASE SHOW DRY DETENTION/WET | | | DETENTION AREAS IN STORM WATER CALS IF YOU HAVE ALL | | | THESE. PLEASE RESUBMIT GEO-TECH REPORT AND ALL | | | ENVRONMENTAL REPORT. | | | | | | 9. ALSO PLEASE SHOW ALL CATCH BASINS NEAREST,AROUND | | | YOUR SITE FOR STORM WATER DRAIN SO YOUR SITE DO NOT GET | | | FLOODED AND HAVE ENOUGH DRAINS. | | | | | | 10. PLEASE PROVIDE A COPY OF SFWMD PERMIT,, GEO-TECH | | | REPORT&STORM WATER QUALITY CALCULATIONS TO 1000 | | | 45TH STREET FOR THEIR APPROVAL BEFORE WE APPROVE. | | | | | | 11. WATER & SEWER PLANS MUST BE APPROVED FROM MANNY G. | | | OF 1000 45TH STREET BEFORE WE ISSUE A PERMIT. | | | | | | PLEASE RESPOND EACH ITEM IN DETAIL TO EXPEDITE YOUR | | | PERMITTING PROCESS | | | | | | RASIK CHOKSHI805-6723 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
8 |
Status |
P |
Date |
2009-05-26 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2009-05-26 |
Time |
09:31 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2009-05-26 |
Time |
09:03 |
Sent To |
|
|
| Notes |
| 2009-05-26 09:12:55 | *****REVISIONS, DATED 04/24/09, APPROVED***** | | | | | | | | | OF THE SUBMITTED NINE REVISED SHEETS, SHEETS E103CR2, | | | E105CR5, AND E112CR3 WERE STAMPED, INITIALED, AND | | | DATED. | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
7 |
Status |
P |
Date |
2009-04-06 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2009-04-06 |
Time |
11:09 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2009-04-06 |
Time |
10:34 |
Sent To |
|
|
| Notes |
| 2009-04-06 10:44:19 | *****REVISIONS, DATED 03/27/09, APPROVED***** | | | | | | | | | REVISED PLAN SHEETS A103CR4, A106CR3, A118CR5, A901CR5, | | | E104CR5, AND E105CR4 WERE STAMPED, INITIALED, AND | | | DATED. | | | | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
6 |
Status |
P |
Date |
2009-04-06 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2009-04-06 |
Time |
10:33 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2009-04-06 |
Time |
10:03 |
Sent To |
|
|
| Notes |
| 2009-04-06 10:33:09 | *****SUBMITTAL APPROVED***** | | | | | | | | | RFI 244 - HORN STROBE MOUNTING ELEVATION IN PUSH WALLS | | | WAS BLOCK STAMPED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
5 |
Status |
P |
Date |
2009-03-10 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2009-03-10 |
Time |
10:33 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2009-03-10 |
Time |
10:33 |
Sent To |
|
|
| Notes |
| 2009-03-10 10:34:43 | REVISION #4 DATED 2/24/09 STAMPED SHEET A901CR4. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2009-02-24 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2009-02-24 |
Time |
14:20 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2009-02-24 |
Time |
13:35 |
Sent To |
|
|
| Notes |
| 2009-02-24 13:37:15 | *****REVISION #3, DATED 1/18/09, APPROVED***** | | | | | | | | | PLAN SHEETS A103CR3, A106CR2, A113CR3, AND A118CR3 WERE | | | STAMPED, INITIALED, AND DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2008-12-17 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-12-17 |
Time |
14:40 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-12-17 |
Time |
14:27 |
Sent To |
|
|
| Notes |
| 2008-12-17 14:39:56 | *****APPROVED***** | | | | | | | | | PLAN SHEETS A002CR1, A103CR2, A104C, A106CR1, A113CR2 & | | | A114CR2, A118CR2, A123C, C001CR3, C004CR2, E102CR2, | | | E111CR2, FP101CR1 THRU FP103CR1, AND FP104C & FP105C | | | WERE STAMPED, INITIALED, AND DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2008-11-04 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-11-04 |
Time |
11:17 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-11-04 |
Time |
11:17 |
Sent To |
|
|
| Notes |
| 2008-11-04 11:26:51 | ***DENIED*** | | | | | | MOST OF THE PREVIOUS COMMENTS HAVE BEEN ADDRESSED. | | | PLEASE SEE THE FOLLOWING FROM THE PREVIOUS REVIEW FOR | | | CORRECTION OR FURTHER CLARIFICATION: | | | | | | 1) OK- PLEASE ADD NFPA 101, 2003 TO THE CODE ANALYSIS | | | ON SHEET A901CR1. | | | | | | 19) OK- PLEASE ILLUSTRATE THE LOCATION OF THE FIRE | | | DEPARTMENT CONNECTION(S) ON SHEET CO12CR1. | | | | | | 20) PLEASE ILLUSTRATE THE LOCATION OF THE DOUBLE CHECK | | | DETECTOR ASSEMBLY AND ADD NOTE REGARDING CHAIN AND LOCK | | | REQUIREMENT IN ADDITION TO ELECTRONIC SUPERVISION. | | | | | | 23) EXIT SIGN IS STILL MISSING ON SHEET E102CR1. | | | | | | ADDITIONAL NOTE FOR CLARIFICATION: | | | HOSE STATIONS SHALL BE PROVIDED WITH 2 1/2" - 1 1/2" | | | CONNECTIONS WITH CHAINS. | | | | | | | | | MIKE WENNERGREN, ASST. FIRE MARSHAL | | | FIRE PLAN REVIEW | | | FIRE PREVENTION (561) 804-4756 | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2008-08-08 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-08-08 |
Time |
10:55 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-08-08 |
Time |
10:55 |
Sent To |
|
|
| Notes |
| 2008-08-08 11:24:15 | ***DENIED*** | | | | | | 1) IN ADDITION TO APPLICABLE BUILDING CODES, LIFE | | | SAFETY TO COMPLY WITH NFPA 101, 2003. | | | | | | 2) ADDRESS ON BUILDING SHALL BE MINIMUM 6" IN HEIGHT, | | | 1" WIDTH AND CONTRASTING WITH BACKGROUND. PLEASE ADD TO | | | ELEVATIONS. | | | | | | 3) KNOX BOX TO BE LOCATED AT WHAT IS CONSIDERED TO BE | | | FRONT ENTRANCE TO BUILDING. CONTACT WPBFR BUREAU OF | | | FIRE PREVENTION AT (561) 804-4724 FOR ASSISTANCE. | | | | | | 4) PROVIDE PRESCRIPTIVE STRENGTH REQUIREMENTS FOR | | | HANDRAILS AND GUARDS. | | | | | | 5) EMERGENCY VEHICLE ACCESS AND WATER SUPPLY TO COMPLY | | | WITH NFPA 1, 2003, CHAPTER-18. | | | | | | 6) ELEVATOR SHALL COMPLY WITH REQUIREMENTS OF ASME | | | A17.1. | | | | | | 7) FIRE RATED DOORS SHALL BE PROVIDED WITH UL LISTED | | | DOOR CLOSERS TO CREATE POSITIVE LATCH. DOOR SCHEDULE ON | | | SHEET A118C. | | | | | | 8) PROVIDE MINIMUM INTERIOR FINISH CLASSIFICATION FOR | | | WALLS AND CEILING. | | | | | | 9) A FACTOR OF .2" PER PERSON HAS BEEN CALCULATED ON | | | SHEET A901C FOR STAIRWAYS. PLEASE NOTE THAT TABLE | | | 7.3.3.1 NFPA 101 USES A FACTOR OF 0.2" FOR LEVEL | | | COMPONENTS AND RAMPS AND 0.3" FOR STAIRWAYS. THIS WILL | | | HAVE AN OVERALL IMPACT ON CALCULATIONS. | | | | | | 10) PLEASE EXPLAIN FACTOR OF .15 FOR DOOR EGRESS. | | | PLEASE NOTE LAST COMMENT REGARDING LEVEL COMPONENTS. | | | | | | 11) CONSTRUCTION, ALTERATION AND DEMOLITION TO COMPLY | | | WITH REQUIREMENTS OF NFPA 241. | | | | | | 12) CLARIFY OCCUPANT CLASSIFICATION FOR EACH AREA. | | | MODERATE HAZARD IS INDICATED IN CODE ANALYSIS UNDER USE | | | OF OCCUPANCY. ADDITIONALLY, PLANS INDICATE VARIOUS | | | PROCESSING AREAS WHICH SEEMS TO SUGGEST INDUSTRIAL | | | USE. | | | | | | | | | 13) SEPARATE SHOP DRAWINGS AND PERMITS REQUIRED FOR | | | FIRE SPRINKLER AND FIRE ALARM SYSTEMS. | | | | | | 14) FIRE ALRM SHALL BE UL CERTIFICATED FOR CENTRAL | | | STATION SERVICE. | | | | | | 15) PENETRATIONS INTO EXIT ENCLOSURES SHALL BE LIMITED | | | AND IN COMPLIANCE WITH SEC. 7.1.3.2 (6), NFPA 101. | | | SHEET M102C | | | | | | 16) DUCT SMOKE DETECTORS SHALL INITIATE A GENERAL FIRE | | | ALARM IN ACCORDANCE WITH LOCAL REQUIREMENTS. | | | | | | 17) NEW FIRE DAMPERS TO BE TESTED FOR CLOSURE IN | | | ACCORDANCE WITH THE REQUIREMENTS OF UL 555. | | | | | | 18) PROVIDE MANUFACTURER SPECIFICATION SHEETS FOR | | | PROPOSED FIRE PUMP. | | | | | | 19) KNOX LOCKING CAPS ARE REQUIRED FOR FIRE DEPARTMENT | | | CONNECTION. SHEET FP 103C | | | | | | 20) PROVIDE DETAIL FOR DOUBLE CHECK DETECTOR ASSEMBLY. | | | IN ADDITION TO ELECTRONIC SUPERVISION, CONTROL VALVES | | | TO BE SECURED WITH CHAIN AND LOCK. | | | | | | 21) PROVIDE LOCATION OF AND MANUFACTURER SPECIFICATIONS | | | FOR GENERATOR. | | | | | | 22) PLEASE SHOW LOCATION OF NEW FIRE HYDRANTS THAT | | | SHALL BE OPERATIONAL PRIOR TO, DURING AND AFTER | | | CONSTRUCTION. | | | | | | 23) EXIT SIGN IS MISSING AT EXTERIOR CORRIDOR DOOR | | | BETWEEN THE LOCKERS AND TOOL/EQUIPMENT ROOM. ELECTRICAL | | | LIGHTING SHEET | | | | | | 24) FIRE ALARM RISER DOES NOT APPEAR TO ILLUSTRATE | | | SMOKE DETCTION DEVICES WITH EXCEPTION OF AIR DUCTS. | | | | | | | | | A RESPONSE LETTER INDICATING HOW AND WHERE ON EACH | | | SHEET EACH COMMENT WAS ADDRESSED WILL HELP EXPEDITE THE | | | PLAN REVIEW PROCESS. | | | | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | | FIRE PLAN REVIEW | | | FIRE PREVENTION (561) 804-4756 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
22 |
Status |
N |
Date |
2009-09-22 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2009-09-16 |
Time |
08:37 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2009-09-16 |
Time |
08:36 |
Sent To |
|
|
| Notes |
| 2009-09-22 08:38:45 | ELECTRICAL COORDINATION STUDY, GAVE TO DEWEY |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
21 |
Status |
N |
Date |
2009-08-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-08-05 |
Time |
07:45 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-08-05 |
Time |
07:45 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
20 |
Status |
N |
Date |
2009-07-10 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2009-07-10 |
Time |
16:30 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2009-07-10 |
Time |
16:30 |
Sent To |
|
|
| Notes |
| 2009-07-10 16:31:08 | GAVE TO ROBERT BROWN |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
19 |
Status |
N |
Date |
2009-07-01 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2009-07-01 |
Time |
08:25 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2009-07-01 |
Time |
08:25 |
Sent To |
|
|
| Notes |
| 2009-07-01 08:26:38 | ELECTRICAL COORDINATION STUDY TO D.PALMER'S DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
18 |
Status |
N |
Date |
2009-06-16 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2009-06-16 |
Time |
15:41 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2009-06-15 |
Time |
15:41 |
Sent To |
|
|
| Notes |
| 2009-06-16 15:42:42 | GAVE TO RON | | 2009-06-16 15:41:53 | MINOR MECHANICAL DUCT REVISIONS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
17 |
Status |
N |
Date |
2009-06-11 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-06-11 |
Time |
13:32 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-06-11 |
Time |
13:32 |
Sent To |
B |
|
| Notes |
| 2009-06-11 13:32:30 | TO JW DESK - HORIZONTAL SHAFT ASSEMBLY |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
16 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2009-05-12 |
Time |
|
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2009-05-12 |
Time |
16:49 |
Sent To |
|
|
| Notes |
| 2009-05-12 16:49:43 | SENT TO C12 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
15 |
Status |
N |
Date |
2009-04-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-04-29 |
Time |
12:55 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-04-29 |
Time |
12:55 |
Sent To |
B |
|
| Notes |
| 2009-05-05 10:39:10 | PLANS ROUTED TO DOUG WISE FOR EXPEDITED REVIEW | | 2009-04-29 12:56:13 | TO SH |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
14 |
Status |
N |
Date |
2009-04-17 |
|
|
Cont ID |
|
| Sent By |
swurafti |
Date |
2009-04-17 |
Time |
15:34 |
Rev Time |
0.00 |
| Received By |
swurafti |
Date |
2009-04-17 |
Time |
15:34 |
Sent To |
E |
|
| Notes |
| 2009-04-17 15:41:27 | TO "DPALMER" DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
13 |
Status |
N |
Date |
2009-04-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-04-08 |
Time |
13:03 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-04-08 |
Time |
13:03 |
Sent To |
I |
|
| Notes |
| 2009-04-08 13:04:55 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2009-04-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-04-02 |
Time |
14:38 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-04-02 |
Time |
14:38 |
Sent To |
|
|
| Notes |
| 2009-04-02 14:42:02 | TO "C19" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2009-04-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-04-02 |
Time |
14:05 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-04-02 |
Time |
14:05 |
Sent To |
E |
|
| Notes |
| 2009-04-02 14:06:15 | TO "DPALMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2009-04-01 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2009-04-01 |
Time |
16:21 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2009-04-01 |
Time |
16:21 |
Sent To |
|
|
| Notes |
| 2009-04-01 16:21:23 | BLDG REVISION/SUBMITTAL TO SMH DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2009-03-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-03-30 |
Time |
16:56 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-03-30 |
Time |
16:56 |
Sent To |
B |
|
| Notes |
| 2009-03-30 16:56:57 | TO "SHILL" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2009-03-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-03-26 |
Time |
17:00 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-03-26 |
Time |
17:00 |
Sent To |
B |
|
| Notes |
| 2009-03-26 17:00:39 | TO "SHILL" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2009-03-24 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-03-24 |
Time |
17:24 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-03-24 |
Time |
17:24 |
Sent To |
E |
|
| Notes |
| 2009-03-24 17:24:32 | SENT TO DVP DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2009-03-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-03-09 |
Time |
11:56 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-03-09 |
Time |
11:56 |
Sent To |
|
|
| Notes |
| 2009-03-09 11:58:45 | TO "COMM" BD#63 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2009-03-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-03-09 |
Time |
11:46 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-03-09 |
Time |
11:46 |
Sent To |
|
|
| Notes |
| 2009-03-09 11:49:00 | TO "COMM" BD#10 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2009-02-23 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-02-23 |
Time |
16:28 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-02-23 |
Time |
16:27 |
Sent To |
|
|
| Notes |
| 2009-02-23 16:27:24 | TO COMM BOARD #37 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-11-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-11-19 |
Time |
16:01 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-11-19 |
Time |
16:01 |
Sent To |
|
|
| Notes |
| 2008-11-19 16:04:03 | TO "COMM" BD#27/PLANS ON RACK/7 ROLLS/3 BOXES--PRIVATE | | | PROVIDER-- |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-09-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-09-29 |
Time |
08:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-09-29 |
Time |
08:50 |
Sent To |
|
|
| Notes |
| 2008-09-29 08:53:25 | TO "COMM" BD#28/PLANS ON RACK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
|
Date |
2008-08-08 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2008-08-08 |
Time |
00:05 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2008-07-11 |
Time |
10:25 |
Sent To |
|
|
| Notes |
| 2008-07-11 10:26:04 | TO "COMM" BD#22/PLANS ON RACK--PRIVATE PROVIDER-- |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
8 |
Status |
P |
Date |
2009-08-03 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2009-08-03 |
Time |
08:26 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2009-08-03 |
Time |
08:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
7 |
Status |
P |
Date |
2009-04-14 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-04-14 |
Time |
17:56 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-04-14 |
Time |
17:41 |
Sent To |
PC |
|
| Notes |
| 2009-04-14 17:56:44 | REVISED M102CR5 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
P |
Date |
2009-04-02 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-04-02 |
Time |
19:16 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-04-02 |
Time |
19:16 |
Sent To |
|
|
| Notes |
| 2009-04-02 19:16:50 | REVISED M102CR4 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2009-03-30 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-03-30 |
Time |
17:56 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-03-30 |
Time |
17:46 |
Sent To |
PC |
|
| Notes |
| 2009-03-30 17:55:59 | THREE SIGNED/SEALED INSTALLATION DETAILS: | | | | | | 1. WALL PROPELLER FAN | | | 2. OUTSIDE AIR MOTORIZED DAMPER | | | 3. PERLIN ATTACHMENT FOR HANGERS |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2009-02-23 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-02-23 |
Time |
19:16 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-02-23 |
Time |
19:15 |
Sent To |
|
|
| Notes |
| 2009-02-23 19:16:16 | REVISED M203CR3. WIND LOAD CALCS FOR APPLIANCES AND | | | DUCTWORK SUBJECT TO BUILDING (STRUCTURAL) PLAN REVIEW. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2008-12-17 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-12-17 |
Time |
14:56 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-12-16 |
Time |
19:40 |
Sent To |
|
|
| Notes |
| 2008-12-17 15:18:50 | PASSED WITH PROVISO | | | | | | *********PROVISO********** | | | | | | PROVIDE MANUFACTURER'S SUBMITTAL DATA SHOWING OUTDOOR | | | APPLIANCES ARE DESIGNED TO RESIST WIND PRESSURES IN | | | ACCORDANCE WITH FBCM 301.13. THIS DOCUMENTATION SHALL | | | BE PROVIDED FOR REVIEW AND APPROVAL PRIOR TO | | | INSTALLATION AND INSPECTION OF OUTDOOR APPLIANCES. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] | | 2008-12-16 20:49:36 | | | | | | | 12/16/08: REVIEW IN PROGRESS. PLANS HAVE BEEN REVIEWED | | | FOR CODE COMPLIANCE AND STAMPED. CORRECTIONS ARE NEEDED | | | TO ENERGY CALCULATIONS. | | | | | | THESE CORRECTIONS HAVE BEEN COMMUNICATED TO PERMIT | | | APPLICANT. REVIEW STATUS WILL BE PASSED ONCE ENERGY | | | CALCULATIONS HAVE BEEN CORRECTED. | | | | | | A PROVISO WILL BE ISSUED RELATED TO WIND RESISTANCE OF | | | ALL OUTDOOR APPLIANCES. | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2008-10-25 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-10-25 |
Time |
14:47 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-10-25 |
Time |
14:46 |
Sent To |
|
|
| Notes |
| 2008-10-25 14:47:50 | REVIEW #: 2ND | | | ACTION: DENIED | | | | | | FBC 2004 CODE FAMILY W/ 2007 SUPPLEMENTS | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | THE FOLLOWING COMMENTS ARE NUMBERED TO CORRESPOND WITH | | | PREVIOUS REVIEW COMMENTS AS WELL AS DESIGNER'S WRITTEN | | | RESPONSES FOR THE PURPOSE OF CONTINUITY. | | | | | | 1 THROUGH 7: OK | | | | | | 8. CONDENSATE DISCHARGING OUTDOORS IS OK. HOWEVER, | | | DETAIL 12 ON PAGE M104CR1 SHOWS CONDENSATE TYING INTO | | | STORM WATER PIPING AT AN ELEVATION LOWER THAN THE STORM | | | WATER INLET. THIS CONFIGURATION CREATES AN OPENING IN | | | THE STORM WATER DRAIN WITHIN THE BUILDING. SHOULD THE | | | STORM WATER DRAIN EVER BACK UP AT A POINT DOWNSTREAM OF | | | THE CONDENSATE PIPE, THIS WILL CAUSE THE STORM WATER TO | | | BACKUP INTO THE CONDENSATE PIPE AND MAKE THE CONDENSATE | | | PIPE A STORM DRAIN PIPE DISCHARGING WITHIN THE | | | BUILDING. THIS IS NOT AN APPROVED PLACE OF CONDENSATE | | | DISPOSAL. SEE FBCM 307.2.1 AND THE DEFINITION OF | | | APPROVED IN SECTION 202 OF FBCM. | | | | | | 9 AND 10: OK | | | | | | 11. PROVIDE PRODUCT APPROVALS AND SUPPORTING | | | DOCUMENTATION FOR WIND RESISTANCE FOR ALL OUTDOOR | | | APPLIANCES WHICH ARE EXPOSED TO WIND, INCLUDING EXHAUST | | | FANS, PACKAGE UNITS AND CONDENSING UNITS. ALL OF THESE | | | APPLIANCES ARE NOT ONLY REQUIRED TO BE SECURED TO | | | RESIST WIND PRESSURES, BUT ALSO BE DESIGNED AND | | | CONSTRUCTED TO RESIST WIND PRESSURES IN ACCORDANCE WITH | | | FBCM 301.13. ALSO, NO INFORMATION COULD BE FOUND IN | | | STRUCTURAL PLANS FOR CONSTRUCTION AND SUPPORTS FOR WIND | | | RESISTANCE RELATED TO EXTERIOR DUCTWORK. PLEASE PROVIDE | | | MISSING INFORMATION IN ACCORDANCE WITH FBCM 301.13. | | | | | | 12. OK | | | | | | 13. WRITTEN RESPONSE INDICATES A CARRIER HAP REPORT IS | | | ATTACHED TO THE WRITTEN RESPONSES FOR THE PURPOSE OF | | | SHOWING COMPLIANCE WITH ASHRAE 62.1-2004. NO SUCH | | | REPORT COULD BE FOUND ATTACHED TO THE WRITTEN | | | RESPONSES. PLEASE PROVIDE THE REPORT MENTIONED IN THE | | | RESPONSE TO DEMONSTRATE COMPLIANCE WITH FBCM 401.1. | | | | | | 14. OK | | | | | | 15. ENERGY CODE COMPLIANCE FORMS HAVE BEEN PROVIDED IN | | | RESPONSE TO THIS COMMENT. HOWEVER, THERE ARE MULTIPLE | | | MITSUBISHI SPLIT-SYSTEMS NOT INCLUDED IN THE ENERGY | | | CODE COMPLIANCE FORM. PLEASE INCLUDE ALL COOLING | | | APPLIANCES IN THE COMPLIANCE FORM. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2008-07-29 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-07-29 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-07-24 |
Time |
16:48 |
Sent To |
|
|
| Notes |
| 2008-07-29 11:49:27 | PRIVATE PROVIDER AUDIT #: 1ST | | | ACTION: DENIED | | | | | | FBC 2004 CODE FAMILY W/ 2007 SUPPLEMENTS | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | 1. M101C: EF 18 IS SHOWN SERVING STORAGE ROOM 122 WITH | | | 2200 TOTAL CFM OF EXHAUST. HOWEVER, THE FAN SCHEDULE ON | | | M106C SHOWS EF 18 PROVIDING 3650 CFM OF EXHAUST. WHICH | | | IS CORRECT? PLEASE COORDINATE FLOOR PLANS AND EQUIPMENT | | | SCHEDULES SHOWING THE REQUIRED DISTRIBUTION OF AIR IN | | | ACCORDANCE WITH FBCM 603.1, 501.1 AND FBCB 106.1.1. | | | | | | 2. M101C AND A002C: THE FOLLOWING ROOMS: 124, 125, 126 | | | AND 127 HAVE A ROOF WHICH IS LOWER THAN THE MAIN ROOF | | | OF THE BUILDING. THIS ROOF HAS MULTIPLE EXHAUST FANS | | | WHICH ARE REQUIRED TO BE ACCESSIBLE FOR SERVICE AND | | | REPLACEMENT IN ACCORDANCE WITH FBCM 306.1. ALSO, WHERE | | | EQUIPMENT AND APPLIANCES REQUIRING ACCESS ARE INSTALLED | | | ON ROOFS OR ELEVATED STRUCTURES AT A HEIGHT EXCEEDING | | | 16 FEET, SUCH ACCESS SHALL BE PROVIDED BY A PERMANENT | | | APPROVED MEANS OF ACCESS, THE EXTENT OF WHICH SHALL BE | | | FROM GRADE OR FLOOR LEVEL TO THE EQUIPMENT AND | | | APPLIANCES? LEVEL SERVICE SPACE IN ACCORDANCE WITH FBCM | | | 306.5. THIS LOWER ROOF IS SHOWN ON PAGE A002C TO HAVE A | | | HEIGHT OF 25 FEET ABOVE GRADE. PLEASE SHOW A PERMANENT | | | MEANS OF ACCESS TO THIS ROOF LEVEL IN ACCORDANCE WITH | | | THIS SECTION. | | | | | | 3. M102C DETAIL 3: STAIR #1 ENCLOSURE 209 IS SHOWN | | | BEING PENETRATED BY A 20X16 EXHAUST DUCT FROM EF 30 ON | | | THE 2ND FLOOR. PENETRATIONS INTO AND OPENINGS THROUGH | | | AN EXIT ENCLOSURE ARE PROHIBITED EXCEPT FOR REQUIRED | | | EXIT DOORS, EQUIPMENT AND DUCTWORK NECESSARY FOR | | | INDEPENDENT PRESSURIZATION, SPRINKLER PIPING, | | | STANDPIPES, ELECTRICAL RACEWAY FOR FIRE DEPARTMENT | | | COMMUNICATION AND ELECTRICAL RACEWAY SERVING THE EXIT | | | ENCLOSURE IN ACCORDANCE WITH FBCB 1019.1.2 AND 1020.5. | | | | | | 4. M102C DETAIL 2: STAIR #1 ENCLOSURE 110 IS SHOWN WITH | | | MULTIPLE DUCT PENETRATIONS OF THIS EXIT ENCLOSURE/EXIT | | | PASSAGEWAY ON THE FIRST FLOOR. THIS AREA ALSO SHOWS A | | | SUPPLY DUCT AND RETURN GRILL SERVING THE EXIT ENCLOSURE | | | FROM VAV-1. THIS METHOD OF EXIT ENCLOSURE VENTILATION | | | IS PROHIBITED. IF VENTILATION IS TO BE PROVIDED FOR | | | THIS ENCLOSURE, IT SHALL BE PROVIDED IN ACCORDANCE WITH | | | ONE OF THE THREE METHODS LISTED IN ACCORDANCE WITH FBCB | | | 1019.1.3. UNDER ANY OF THESE CONDITIONS, THE EXIT | | | ENCLOSURE VENTILATION SYSTEM SHALL BE INDEPENDENT OF | | | OTHER BUILDING VENTILATION SYSTEMS IN ACCORDANCE WITH | | | THIS SECTION. | | | | | | 5. M102C DETAIL 3: RELIEF AIR DUCT FROM 1ST FLOOR | | | MECHANICAL ROOM CALLS FOR 24X12 WHILE DETAIL 5 CALLS | | | FOR THIS SAME DUCT TO BE 20X12. WHICH IS CORRECT? | | | PLEASE CLARIFY IN ACCORDANCE WITH FBCM 603.1 AND FBCB | | | 106.1.1. | | | | | | 6. M102C DETAIL 1: EF #31 IN CORRIDOR 123 IS PROVIDING | | | VENTILATION FOR THIS EXIT ENCLOSURE. THERE IS NO | | | INDICATION ON PLANS WHAT THE SOURCE OF MAKEUP AIR WILL | | | BE FOR THE 300 CFM OF EXHAUST. MECHANICAL VENTILATION | | | SHALL BE PROVIDED BY A METHOD OF SUPPLY AIR AND RETURN | | | OR EXHAUST AIR. THE AMOUNT OF SUPPLY AIR SHALL BE | | | APPROXIMATELY EQUAL TO THE AMOUNT OF RETURN AND EXHAUST | | | AIR IN ACCORDANCE WITH FBCM 403.1. ALSO, PLEASE SHOW | | | THE SOURCE OF SUPPLY OR MAKEUP AIR TO BE IN COMPLIANCE | | | WITH FBCM 401.4, 401.5 AND 401.6. | | | | | | 7. M102C DETAIL 3: NOTE 17 CALLS FOR EF 30 TO BE | | | MOUNTED VERTICALLY ON A WALL. THE ONLY INSTALLATION | | | DETAIL FOUND IN PLANS FOR INLINE FANS IS FOR HORIZONTAL | | | INSTALLATIONS. PROVIDE DETAIL SHOWING VERTICAL | | | INSTALLATION, VIBRATION ISOLATION AND SUPPLEMENTAL | | | RESTRAINT METHODS TO BE USED. EQUIPMENT AND APPLIANCES | | | SHALL BE INSTALLED AS REQUIRED BY THE TERMS OF THEIR | | | APPROVAL, IN ACCORDANCE WITH THE CONDITIONS OF THE | | | LISTING, THE MANUFACTURER?S INSTALLATION INSTRUCTIONS | | | AND THIS CODE IN ACCORDANCE WITH FBCM 304.1. WHERE | | | VIBRATION ISOLATION OF EQUIPMENT AND APPLIANCES IS | | | EMPLOYED, AN APPROVED MEANS OF SUPPLEMENTAL RESTRAINT | | | SHALL BE USED TO ACCOMPLISH THE SUPPORT AND RESTRAINT | | | IN ACCORDANCE WITH FBCM 301.10 | | | | | | 8. M102C DETAIL 5: MECHANICAL ROOM DETAIL AND | | | CONDENSATE TRAP DETAIL SHOWS THE CONDENSATE FROM AHU 2 | | | DISCHARGING TO A FLOOR DRAIN. THIS DRAIN IS TIED TO THE | | | SANITARY SEWER SYSTEM. AIR CONDITIONING CONDENSATE | | | SHALL NOT DISCHARGE INTO THE SANITARY SEWER SYSTEM IN | | | ACCORDANCE WITH LOCAL ORDINANCE ARTICLE 3 SECTION | | | 90-125(5). CONDENSATE FROM ALL COOLING COILS AND | | | EVAPORATORS SHALL BE CONVEYED FROM THE DRAIN PAN OUTLET | | | TO AN APPROVED PLACE OF DISPOSAL IN ACCORDANCE WITH | | | FBCM 307.2.1. CONDENSATE SHALL NOT DISCHARGE INTO A | | | STREET, ALLEY OR OTHER AREAS SO AS TO CAUSE A | | | NUISANCE. | | | NOTE: THESE REQUIREMENTS APPLY TO ALL CONDENSATE | | | DISPOSAL SYSTEMS FROM ALL COOLING COILS. SHOW | | | COMPLIANCE WITH THESE SECTIONS. | | | | | | 9. M102C DETAIL 2: VAV #1 ON FLOOR PLAN CALLS FOR 355 | | | CFM OF SUPPLY. HOWEVER, EQUIPMENT SCHEDULE ON M106C | | | CALLS FOR A MAXIMUM CFM OF 225 FOR THE SAME VAV. PLEASE | | | COORDINATE FLOOR PLANS WITH EQUIPMENT SCHEDULES. AIR | | | DISTRIBUTION SYSTEMS SHALL BE DESIGNED AND INSTALLED TO | | | SUPPLY THE REQUIRED DISTRIBUTION OF AIR IN ACCORDANCE | | | WITH FBCM 603.1. | | | | | | 10. M102C: FLOOR PLAN SHOWS AHU #2 SERVING THE EMPLOYEE | | | BREAK ROOM AND AHU #2 ALSO SERVING THE ADMIN AREA. | | | THESE APPLIANCES APPEAR TO BE MISLABELED. THE AHU | | | SERVING THE ADMIN AREA IS ATTACHED TO ACCU #1 AND THE | | | AHU SERVING THE EMPLOYEE BREAK AREA IS ACTUALLY A | | | PACKAGE UNIT. PLEASE COORDINATE FLOOR PLANS AND | | | EQUIPMENT SCHEDULES, SHOWING ALL APPLIANCES PROPERLY | | | LABELED IN RELATION TO THE AREAS BEING SERVED IN | | | ACCORDANCE WITH FBCM 301.1, 304.11 AND FBCB 106.1.1. | | | | | | 11. M104C: ROOF CURB DETAIL HAS NO INFORMATION | | | REGARDING ATTACHMENT OF CURB TO STRUCTURE OR ATTACHMENT | | | OF FAN TO ROOF CURB. MECHANICAL EQUIPMENT, APPLIANCES | | | AND SUPPORTS THAT ARE EXPOSED TO WIND SHALL BE DESIGNED | | | AND INSTALLED TO RESIST THE WIND PRESSURES ON THE | | | EQUIPMENT AND THE SUPPORTS AS DETERMINED IN ACCORDANCE | | | WITH FBCM 301.13. PROVIDE SUFFICIENT DETAIL WITH | | | SUPPORTING WIND LOAD CALCULATIONS AS NEEDED (FOR | | | BUILDING PLAN REVIEW) TO SHOW THE INSTALLATION OF ALL | | | APPLIANCES AND DUCTWORK WHICH IS EXPOSED TO WIND IS | | | SUFFICIENT TO RESIST ANTICIPATED WIND PRESSURES IN | | | ACCORDANCE WITH THIS SECTION AND FBCB SECTION 1609. | | | ALSO PROVIDE SUPPORTING DOCUMENTATION SHOWING OUTDOOR | | | APPLIANCES THEMSELVES DESIGNED TO RESIST WIND | | | PRESSURES. THIS INCLUDES ROOFTOP FANS AS WELL AS GROUND | | | MOUNTED PACKAGE UNITS AND CONDENSING UNITS. | | | | | | 12. M105C: THE RELIEF AIR DUCT WHICH IS SHOWN | | | DISCHARGING ONTO THE RECYCLING FLOOR IS ALSO SHOWN | | | ATTACHED TO THE RETURN AIR PLENUM OF AHU #1. ACCORDING | | | TO THE SEQUENCE, DAMPERS ARE TO MODULATE BASED ON THE | | | PRESSURE IN THE CONDITIONED SPACE TO ALLOW RELIEF AIR | | | TO BE DISCHARGED. HOWEVER, THE RETURN AIR PLENUM WILL | | | BE UNDER A CONSTANT NEGATIVE PRESSURE. THIS DESIGN WILL | | | CAUSE THE RELIEF AIR DUCT TO ACT AS AN INTAKE DUCT, | | | DRAWING AIR FROM THE RECYCLING FLOOR INTO THE ADMIN | | | AREA. THIS DESIGN IS NOT IN COMPLIANCE WITH FBCM | | | 401.5.1, 403.2.1(1) AND FBCM 603.1. PLEASE SHOW A | | | DESIGN WHICH IS CAPABLE OF ACHIEVING THE DESIGN INTENT | | | AS DESCRIBED IN THE RELIEF AIR SEQUENCE OF OPERATIONS. | | | ALSO, THE RELIEF AIR SEQUENCE CALLS FOR 3 DIFFERENT | | | MODULATING DAMPERS TO BE OPENED IN STAGES. FLOOR PLANS | | | AND CONTROL DIAGRAM ONLY SHOW ONE MOTORIZED DAMPER ON | | | THE RELIEF AIR SYSTEM. PLEASE CLARIFY. | | | | | | 13. OUTSIDE AIR: NO INFORMATION REGARDING THE REQUIRED | | | RATES OF OUTSIDE AIR HAS BEEN PROVIDED. PLEASE PROVIDE | | | OUTSIDE AIR CALCULATIONS SHOWING THE VENTILATION METHOD | | | USED, SUCH AS FBCM TABLE 403.3, THE VENTILATION RATE | | | METHOD OF AHSRAE 62.1-2004 OR THE IAQ METHOD OF ASHRAE | | | 62.1-2004 AS ALLOWED UNDER FBCM 403.4. PROVIDE | | | SUPPORTING DOCUMENTATION AND/OR CALCULATIONS | | | APPROPRIATE FOR THE METHOD USED IN ACCORDANCE WITH FBCM | | | 401.1. IT IS ACKNOWLEDGED THAT CO2 CONTROLS ARE SHOWN | | | ON THE VAV SEQUENCE, BUT THE REQUIRED RATES OF | | | VENTILATION FOR THE SPACES BEING SERVED ARE NOT | | | PROVIDED ON PLANS. ALSO, THE EMPLOYEE BREAK ROOM IS NOT | | | SERVED BY A VAV SYSTEM AND IS THEREFORE NOT ACCOUNTED | | | FOR IN THIS SEQUENCE. | | | | | | 14. REHEAT: THE CO2 CONTROL SEQUENCE CALLS FOR ELECTRIC | | | REHEAT OF VAV SYSTEMS WHEN OUTSIDE AIR IS REQUIRED TO | | | PREVENT OVER-COOLING. REHEATING OR THE SIMULTANEOUS | | | OPERATION OF THE HEATING AND COOLING SYSTEMS TO THE | | | SAME ZONE ARE PROHIBITED IN ACCORDANCE WITH FBCB | | | 13-407.1.ABC.2.1.1. IF REHEAT IS TO BE USED, PLEASE | | | PROVIDE DOCUMENTATION SHOWING AT LEAST ONE OF THE | | | EXCEPTIONS UNDER THIS SECTION HAS BEEN SATISFIED. | | | | | | 15. ENERGY: ENERGY CALCULATIONS WERE NOT PROVIDED WITH | | | THIS APPLICATION FOR PERMIT. PROVIDE A COMPLETED ENERGY | | | CODE COMPLIANCE FORM IN ACCORDANCE WITH FBCM 301.2 AND | | | FBCB 13-101.1.1. ALSO, COOLING LOAD CALCULATIONS SHALL | | | BE APPENDED TO THE ENERGY CODE COMPLIANCE FORM IN | | | ACCORDANCE WITH FBCB 13-407.1.ABC.1. AUDIT FOR | | | COMPLIANCE WITH THE REQUIREMENTS OF FBCB CHAPTER 13 CAN | | | NOT BE PERFORMED AT THIS TIME. | | | | | | 16. THIS PERMIT APPLICATION WAS SUBMITED UNDER THE | | | PRIVATE PROVIDER PROVISIONS OF FS 553.791. AS SUCH THE | | | FOLLOWING REQUIREMENTS HAVE NOT BEEN SATISFIED: | | | A) A NOTICE TO BUILDING OFFICIAL HAS NOT BEEN PROVIDED | | | AS REQUIRED UNDER FS 553.791(4). | | | B) PLANS FOR THE "SORT ENCLOSURE" AIR CONDITIONING | | | SYSTEMS HAVE BEEN SUBMITTED AS SHOP DRAWINGS, BUT THEY | | | ARE ACTUALLY SIGNED AND SEALED PLANS BY THE DESIGNER OF | | | RECORD FOR THIS PROJECT. EITHER WAY, THESE PLANS WERE | | | NOT STAMPED AS REVIEWED AND NO AFFIDAVIT WAS PROVIDED | | | FOR THESE PLANS BY THE PRIVATE PROVIDER AS REQUIRED | | | UNDER FS 553.791(6). THESE PLANS WILL NOT BE AUDITED | | | PRIOR TO REVIEW AND SUBMISSION OF AFFIDAVIT BY THE | | | PRIVATE PROVIDER. | | | | | | PLEASE RESPOND TO EACH COMMENT IN WRITING WITH A | | | DETAILED EXPLANATION OF HOW EACH COMMENT HAS BEEN | | | ADDRESSED AS WELL AS WHERE THE SUPPORTING INFORMATION | | | CAN BE FOUND. ALSO, PLEASE RETURN ONE OLD/VOIDED SET OF | | | PLANS FOR REFERENCE. THESE STEPS WILL ASSIST IN A | | | TIMELY AUDIT OF RESUBMITTED PLANS. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2008-10-07 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-10-07 |
Time |
09:56 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-10-06 |
Time |
14:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2008-07-16 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-07-16 |
Time |
16:05 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-07-16 |
Time |
16:05 |
Sent To |
|
|
| Notes |
| 2008-07-16 16:44:41 | AUDIT DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | FBC-2004 CHAPTER 11 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1. PLEASE SUBMIT AFFIDAVITS AS REQUIRED IN FS 553.791 | | | FOR EACH DISCIPLINE. | | | | | | 2. SHT A101C MEN'S AND WOMEN'S TOILET AREAS ARE | | | INDICATED BY DETAIL 1/A101 - A111 - A112. SHTS A101, | | | A111 & A112 NOT SUBMITTED. PLEASE CORRELATE. SECTIONS | | | 106.1.1 & 106.1.3. THIS IS INDICATED IN MANY AREAS WITH | | | MANY DETAILS AND MANY SHEETS WHERE THE DETAILS DO NOT | | | CORRELATE WITH SHEETS SUBMITTED. | | | | | | 3. SHT A105C DETAIL 7 SHOW THE CLEAR FLOOR SPACE FOR | | | ACCESSIBLE W/C & LAV. SECTIONS 11-4.16.2 & 11-4.19.3. | | | | | | 4. SHT A105C DETAILS 8 C & D. SHOW CLEARANCES AND | | | INDICATE FAUCET TYPES PER SECTIONS 11-4.19.2 & | | | 11-4.19.5. | | | | | | 5. SHT A111C DETAILS 1, 2, 3 & 4 SHOW THE CLEAR FLOOR | | | SPACE FOR ACCESSIBLE W/C'S, LAVS, URINALS & DRINKING | | | FOUNTAINS PER SECTIONS 11-4.15.5(1), 11-4.16.2, | | | 11-4.18.3 & 11-4.19.3. | | | | | | 6. SHT A112C DETAILS 14 & 17 INDICATE THE FAUCET TYPE | | | PER SECTIONS 11-4.19.5 & 11-4.24.7. | | | | | | 7. SHT A112C DETAIL 17 SHOW SINK DEPTH PER SECTION | | | 11-4.24.4. (SHOWS 12" - MAX 6-1/2"). | | | | | | 8. MINIMUM 3 SETS OF PLANS REQUIRED TO BE SUBMITTED PER | | | SECTION 106.1. ONLY ONE SET OF ARCHITECTURAL, | | | STRUCTURAL, LANDSCAPE, IRRIGATION, PLUMBING, ELECTRIC & | | | MECHANICAL. SUBMITTED. | | | | | | 9. ALL SHEETS SUBMITTED HAVE NOT BEEN REVIEWED AND | | | SIGNED OFF BY THE PRIVATE PROVIDER. SECTION | | | 553.791(1)(H)(I). (SEE LANDSCAPE, IRRIGATION & FIRE | | | PROTECTION). | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2008-10-07 |
|
|
Cont ID |
|
| Sent By |
kdfreema |
Date |
2008-10-07 |
Time |
14:47 |
Rev Time |
0.00 |
| Received By |
kdfreema |
Date |
2008-10-07 |
Time |
14:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2008-07-30 |
|
|
Cont ID |
|
| Sent By |
kdfreema |
Date |
2008-07-30 |
Time |
13:34 |
Rev Time |
0.00 |
| Received By |
kdfreema |
Date |
2008-07-30 |
Time |
13:34 |
Sent To |
|
|
| Notes |
|
|
|