| Plan Review Stops For Permit 08070216 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2009-07-07 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2009-07-07 |
Time |
13:28 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2009-07-07 |
Time |
13:28 |
Sent To |
|
|
| Notes |
| 2009-07-07 13:40:24 | BUILDING REVIEW APPROVED WITH PROVISO. | | | | | | 1- RE-SUBMIT SPIRAL STAIRS DRAWINGS. SEE COMMENTS ON | | | DRAWINGS SUBMITTED. | | | | | | 2- PROVIDE GARAGE DOOR AND DOORS AND WINDOWS STRUCTURAL | | | BUCK DETAILS WITH COMPLETE INFORMATION. DETAILS | | | PROVIDED ARE MISSING FASTENERS TYPE AND SPACING. | | | | | | 3- RE-SUBMIT SURVEYS. SEE COMMENTS ON SURVEYS | | | SUBMITTED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2009-04-02 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2009-04-02 |
Time |
16:57 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2009-04-02 |
Time |
16:56 |
Sent To |
PC |
|
| Notes |
| 2009-04-02 17:12:29 | RESIDENTIAL (R3) ADDITION, BUILDING REVIEW SECOND | | | CHECKLIST. | | | REVIEW UNDER 2004 FLORIDA RESIDENTIAL CODE WITH 2007 | | | REVISIONS. | | | | | | NOTE: PLANS SUBMITTED ARE COMPLETELY DIFFERENT THAN | | | THOSE SUBMITTED THE FIRST TIME. | | | | | | 1- PROVIDE RECORDED NOTICE OF COMMENCEMENT. SEC. 713.13 | | | FLORIDA STATUTE. | | | ***NOTE: THIS MAY BE RECORDED LATER AT TIME OF PERMIT | | | PICK UP. | | | | | | 2- PERMIT VALUATION WAS UPDATED AS REQUIRED BY SEC. | | | 108.3 CITY AMENDMENTS TO FBC 2004. OWES $346.78 FOR | | | UPDATE VALUATION AND FOR RADON FEES. | | | | | | 3- PROVIDE 2 COPIES OF PRODUCT APPROVALS AS REQUIRED BY | | | DCA RULE 9B-72 FOR: | | | A) FLAT ROOF ASSEMBLY FOR ROOF TOP PATIO. AND, CLEARLY | | | IDENTIFY SPECIFIC APPROVED ASSEMBLY TO BE INSTALLED. | | | PROVIDE RAS 117 CALCULATIONS FOR NAIL ENHANCING AT | | | PERIMETER AND CORNER AREAS AS REQUIRED BY GENERAL | | | LIMITATION #7 THAT IS TYPICALLY SHOWN ON SELECTED | | | ASSEMBLY. CHECK IF CALCULATIONS NEED TO BE SIGNED AND | | | SEALED BY ARCHITECT OR ENGINEER, IF THEY DO, THEN THEY | | | NEED TO BE PROVIDED. CHECK GENERAL LIMITATION ON LAST | | | PAGE OF PRODUCT APPROVAL FOR REQUIREMENTS. | | | NOTE: IF SELECTED ASSEMBLY IS LIMITED BY GENERAL | | | LIMITATION #9, THEN IT MAY NOT BE USED IN THIS AREA | | | BECAUSE IT WILL NOT MEET THE REQUIRED DESIGN PRESSURES | | | OF THIS AREA. | | | | | | B) SECOND FLOOR PATIO #2 ASSEMBLY THAT RECEIVES THE | | | FLOOR TILE. CHECK FOR UPLIFT RESISTANCE AND PROVIDE | | | REQUIRED INFORMATION. EG: RAS 117 CALCULATIONS. SEE | | | COMMENTS ON ITEM 3A ABOVE. | | | | | | C) GARAGE DOOR. PROVIDE PRODUCT APPROVAL FOR GARAGE | | | DOOR SIZE AS SHOWN ON PLANS. PRODUCT APPROVAL FL9462-R0 | | | SUBMITTED IS FOR 16' MAX. WIDE DOORS. THERE IS A | | | SEPARATE PRODUCT APPROVAL FOR SMALLER DOORS. | | | | | | D) (CAST-CRETE) 4", 6" & 12" PRECAST LINTELS. NOA | | | 03-0605.04 SUBMITTED EXPIRED ON 09/11/2008. NEED TO | | | PROVIDE CURRENT ONE. | | | | | | E) CASEMENT WINDOWS. NOA 05-1129.11 SUBMITTED EXPIRED | | | ON MAY 22, 2008. NEED TO PROVIDE CURRENT ONE. | | | | | | 4- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC 2004. | | | NEED TO REVISE LIST OF PRODUCT APPROVALS SHOWN ON PLANS | | | AND ADDITIONAL LIST PROVIDED TO INCLUDE THE ADDITIONAL | | | PRODUCT APPROVALS AND REVISE EXPIRED ONES. ALSO, LIST | | | IS MISSING METAL ROOFING, FLAT ROOF, ETC. | | | | | | NOTE: PERSON TO REVIEW AND APPROVE THE PRODUCT APPROVAL | | | IS THE ENGINEER WHO SIGNED AND SEALED THE PLANS. HE IS | | | THE DESIGNER OF RECORD RESPONSIBLE FOR THESE PLANS. | | | | | | 5- SHEET A2.0: REVISE ATTIC WITH STORAGE LIVE LOAD | | | SHOWN ON CONSTRUCTION NOTE #12. SEE TABLE R301.5 OF | | | 2004 FLORIDA RESIDENTIAL CODE AND REVISE AS REQUIRED. | | | | | | 6- SHEETS A9.1, A9.2 AND A9.3 NEED TO BE SIGNED AND | | | SEALED BY THE ENGINEER OF RECORD. ALSO, PROVIDE HIS | | | TITLE BLOCK AND INFORMATION ON THESE SHEETS. | | | | | | 7- A) PROVIDE COMPLETE INFORMATION FOR INSTALLATION OF | | | SPIRAL STAIRCASE TO SHOW COMPLIANCE WITH THE DESIGN | | | LOADS OF SEC. R301 OF 2004 FLORIDA RESIDENTIAL CODE. | | | SPECIFY ALL CONNECTIONS AT TOP AND BOTTOM. | | | | | | B) PROVIDE COMPLETE SPECIFICATIONS AND CUT SHEETS FOR | | | SPECIFIC SPIRAL STAIRCASE TO BE INSTALLED TO SHOW | | | COMPLIANCE WITH SEC. R311.5.8 OF 2004 FLORIDA | | | RESIDENTIAL CODE. | | | | | | 8- PROVIDE COMPLETE CONSTRUCTION DETAILS/SECTIONS AND | | | SPECIFICATIONS FOR HANDRAILS AND GUARDRAILS TO VERIFY | | | COMPLIANCE WITH TABLE R301.5 (AND FOOTNOTES D & F), | | | SEC. 312 OF 2004 FLORIDA RESIDENTIAL CODE. MISSING | | | CONSTRUCTION OF STAIRS AND RAILINGS TO RESIST LOADS | | | REQUIRED BY TABLE R301.5, SPACING BETWEEN PICKETS, ETC. | | | STAIRWAY SECTION ON SHEET A9.2 IS MISSING THIS | | | INFORMATION AND THERE IS NOT INFORMATION GIVEN FOR 2ND | | | AND 3RD FLOOR GUARDRAILS. | | | | | | 9- PROVIDE STRUCTURAL BUCK DETAILS FOR GARAGE DOOR AND | | | FOR ALL OTHER DOORS AND WINDOWS. SEE PRODUCT APPROVALS | | | FOR SIZE OF BUCK REQUIRED AND PROVIDE FULL SUPPORT TO | | | THE DOOR AND WINDOW FRAME AS REQUIRED BY SEC. R613.6 OF | | | 2004 FLORIDA RESIDENTIAL CODE. NO INFORMATION PROVIDED. | | | | | | 10- SURVEY NEEDS TO HAVE SURVEYOR'S ORIGINAL SIGNATURE | | | (NOT COPY) AS REQUIRED BY CHAPTER 472 FLORIDA STATUTE. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2008-10-17 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2008-10-17 |
Time |
09:39 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2008-10-17 |
Time |
09:38 |
Sent To |
PC |
|
| Notes |
| 2008-10-17 10:05:24 | RESIDENTIAL (R3) ADDITIONS AND ALTERATIONS, BUILDING | | | REVIEW CHECKLIST. | | | REVIEW UNDER 2004 FLORIDA RESIDENTIAL CODE WITH 2007 | | | REVISIONS. | | | | | | 1- DRAWINGS NEED TO HAVE THE STRUCTURAL REVIEW OF AN | | | ARCHITECT OR ENGINEER AS REQUIRED BY SEC. 101.2.2 OF | | | THE IBHS (GUIDELINES FOR HURRICANE RESISTANT | | | RESIDENTIAL CONSTRUCTION) CITED ON TITLE SHEET OF | | | DRAWINGS SUBMITTED. DRAWINGS INCLUDE EXISTING | | | CONSTRUCTION AND NEW ADDITION. EXISTING AND PROPOSED | | | STRUCTURES DON'T COMPLY WITH THE PRESCRIPTIVE METHOD OF | | | THE IBHS GUIDELINES. ARCHITECT OR ENGINEER TO CERTIFY | | | EXISTING AND PROPOSED NEW STRUCTURE IS STRUCTURALLY | | | SOUND IN ITS ENTIRETY. SEC. 106.1 OF CITY AMENDMENTS TO | | | FBC 2004. EXISTING WALLS TO REMAIN DON'T COMPLY WITH | | | THE IBHS PRESCRIPTIVE REQUIREMENTS. NEED TO SHOW ALL | | | REINFORCING, SHEARWALLS, DESIGN COMPLIANCE WITH SEC. | | | 105 FOR NONRECTANGULAR PLAN SHAPES AND PROPER | | | REINFORCING AT THE END OF EACH OPENINGS. | | | | | | 2- NEED RECORDED NOTICE OF COMMENCEMENT AS REQUIRED BY | | | SEC. 713.13 FLORIDA STATUTE. | | | ***NOTE: THIS MAY BE SUBMITTED LATER AT TIME OF PERMIT | | | PICK UP. | | | | | | 3- AFTER PLANS ARE REVISED BRING THEM TO PALM BEACH | | | COUNTY (2300 N. JOG RD (561)233-5120) TO VERIFY IF | | | IMPACT FEES ARE DUE. BRING BACK STAMPED PLANS AND COPY | | | OF PAID RECEIPT IF FEES ARE DUE. | | | | | | 4- PROVIDE COMPLETE DEMOLITION PLANS AND SHOW SHORING | | | FOR STRUCTURES TO REMAIN. SEC. 101.6 OF 2004 FLORIDA | | | EXISTING BUILDING CODE. CLEARLY IDENTIFY WHAT'S GOING | | | TO BE REMOVED AND WHAT'S STAYING. | | | | | | 5- UPDATE DESIGN CRITERIA. CURRENT CODE IS THE 2004 FBC | | | WITH 2007 REVISIONS. | | | | | | 6- FLOOR PLANS AND EXTERIOR ELEVATIONS DON'T MATCH | | | FLOOR PLANS. REVISE TYPE AND SIZE OF WINDOWS TO MATCH | | | FLOOR PLANS. ALSO, MISSING A WINDOW ON EAST ELEVATION. | | | | | | 7- MISSING THE WEST ELEVATION. NEED TO PROVIDE THIS | | | DRAWING. SEC. 106.3.5 CITY AMENDMENTS TO FBC 2004. | | | | | | 8- PROVIDE COMPLETE STAIR SECTION AND SPECIFICATIONS. | | | RISER OF 7 3/4" AND TREADS OF 10" DON'T COMPLY WITH | | | RISER TREAD RATIO OF SEC. R311.5.3.2 OF 2004 FLORIDA | | | RESIDENTIAL CODE. REVISE AS REQUIRED. | | | | | | 9- SHEET A-2: | | | A) PROPOSED ROOF PLAN: SPECIFY CALCULATED UPLIFT | | | PRESSURES AND SPECIFY ALL TRUSS CONNECTORS, INCLUDING | | | THE MAIN FRAMING MEMBERS LIKE TRUSS GIRDERS TO VERIFY | | | COMPLIANCE WITH SEC. R301 OF 2004 FLORIDA RESIDENTIAL | | | CODE. | | | | | | B) PROPOSED ROOF PLAN LAYOUT IS NOT DRAWN CORRECTLY. | | | CONNECTIONS OF HIPS WITH RIDGES ARE NOT DRAWN CORRECTLY | | | AND DON'T MATCH EXTERIOR ELEVATIONS. REVISE AS | | | REQUIRED. | | | | | | C) REVISE ROOF SHEATHING KEY PLAN SHOWING ROOF ZONES. | | | MISSING ROOF ZONE 3. SEE FIGURE R301.2(8) OF 2004 | | | FLORIDA RESIDENTIAL CODE. | | | | | | D) REVISE ROOF SHEATHING NOTES. REVISE SIZE OF PLYWOOD, | | | TYPE OF NAIL (NEED 8D RING SHANK) AND NAILING SPACING | | | ON ROOF ZONE 3 (NEED 4" O.C.).. SEE SEC. R803.2.3.1 OF | | | 2004 FLORIDA RESIDENTIAL CODE AND REVISE AS REQUIRED. | | | | | | E) PROVIDE COMPLETE FRAMING DETAILS AND SPECIFICATIONS | | | FOR FRAMING AT STAIRWAY OPENING. UPPER FLOOR FRAMING | | | PLAN DOESN'T PROVIDE ANY SPECIFICATIONS AND NUMBER OF | | | JOISTS. SEC. R501.2 OF 2004 FLORIDA RESIDENTIAL CODE. | | | | | | F) SPECIFY SIZE OF ATTIC ACCESS ON FIRST FLOOR IN | | | GARAGE AREA. SEC. R807.1 OF 2004 FLORIDA RESIDENTIAL | | | CODE. | | | | | | G) SPECIFY SIZE AND LOCATION OF ATTIC ACCESS ON SECOND | | | FLOOR ROOF. SEC. R807.1 OF 2004 FLORIDA RESIDENTIAL | | | CODE. | | | | | | H) CLARIFY DESIGN PRESSURES FOR ENTRY DOORS. WHAT'S | | | -+8.00 ?. | | | | | | I) UPDATE ALL NOTES. CURRENT CODE IS 2004 FBC WITH 2007 | | | REVISIONS. | | | | | | J) PROVIDE CALCULATIONS SHOWING HOW FOOTINGS FOR A TWO | | | STORY MASONRY BUILDING ARE DESIGNED BASED ON SOIL | | | BEARING CAPACITY OF 2000 PSF. SEC. R401.2 OF 2004 | | | FLORIDA RESIDENTIAL CODE. SEE NOTES #4 AND #12.. | | | | | | K) PROVIDE CLEAR AREA TABULATION. INCLUDE ALL AREAS. | | | EG: GARAGE, A/C AREAS PORCHES, ETC. PER FLOOR. CLEARLY | | | IDENTIFY EXISTING AND NEW. NEED THIS INFORMATION TO | | | PROPERLY EVALUATE RADON FEES AND CONSTRUCTION | | | VALUATION. | | | | | | L) VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO | | | LOW. SEC. 108.3 CITY AMENDMENTS TO FBC 2004. NEED TO | | | INCLUDE ALL DESIGN FEES, DEMOLITION, NEW CONSTRUCTION | | | INCLUDING ALL MATERIALS AND LABOR. | | | | | | M) PLANS SHOW FUTURE WOOD DECK. PROVIDE COMPLETE DESIGN | | | INFORMATION NOW OR SEPARATE PERMIT WILL BE REQUIRED. | | | | | | 10- SHEET A-3: | | | A) CLEARLY IDENTIFY ON FLOOR PLANS WHERE ARE THE CROSS | | | SECTIONS TAKEN AT TO FACILITATE PLAN REVIEW AND AVOID | | | CONFLICTS OR DELAYS. MAKE SURE SECTIONS MATCH | | | INFORMATION SHOWN ON FLOOR PLANS. | | | | | | B) EXTERIOR WALL SECTIONS: PROVIDE SPECIFICATION OF HOW | | | ATTACHING NEW MASONRY WALL TO EXISTING MASONRY WALL. | | | EG: SEE FOOTING AREA ON EXISTING INTERIOR BEARING WALL | | | AND CONNECTION ON EXISTING MASONRY WALL. SEE COMMENTS | | | ON PLANS. | | | | | | C) ROOF SHEATHING SPECIFICATIONS TO MATCH NOTES ON | | | SHEET A-2. SEE COMMENT # 9(D) ABOVE AND COORDINATE | | | INFORMATION. | | | | | | 11- RESUBMIT PRODUCT APPROVAL FOR GARAGE DOOR. FL10763 | | | SUBMITTED IS FOR CODE VERSION 2007. NEED TO PROVIDE | | | PRODUCT APPROVAL FOR CODE VERSION 2004 WHICH IS THE | | | CODE IN EFFECT NOW. | | | ***NOTE: PLEASE MAKE SURE DOORS WILL MEET THE DESIGN | | | PRESSURES CALCULATED ON PLANS. | | | | | | 12- ALL DOORS AND WINDOWS PRODUCT APPROVALS: CLEARLY | | | MARK ON PRODUCT APPROVAL DRAWINGS SPECIFIC SIZE, TYPE | | | OF GLASS TO VERIFY COMPLIANCE WITH THE DESIGN PRESSURES | | | CALCULATED ON THE PLANS. | | | | | | 13- PROVIDE PRODUCT APPROVAL AS REQUIRED BY DCA RULE | | | 9B-72 FOR ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED | | | ON PLANS. PROVIDE ONLY THE FLORIDA PRODUCT APPROVAL | | | COVER PAGE AND PAGE WHERE CONNECTOR IS SHOWN. | | | | | | 14- DESIGNER OF RECORD FOR THIS PROJECT NEED TO REVIEW | | | AND APPROVE IN WRITING (NOT SIGNING AND SEALING) ALL | | | PRODUCT APPROVALS AS REQUIRED BY SEC. 106.3.3 CITY | | | AMENDMENTS TO FBC 2004. | | | | | | 15- A) SUBMIT REVISED ENERGY CALCULATIONS FORM | | | 600A-04R. | | | | | | B) OWNER/AGENT TO SIGN AND DATE BOTTOM OF FORM AS WELL. | | | | | | 16- PLEASE RETURN REVIEWED AND MARKED SET OF PLANS | | | AFTER CORRECTIONS ARE DONE TO ORIGINAL DRAWINGS TO | | | EXPEDITE THE REVIEW PROCESS. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-07-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-07-24 |
Time |
08:19 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-07-24 |
Time |
08:19 |
Sent To |
|
|
| Notes |
| 2008-07-24 08:21:53 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | | | | 1.PROVIDE A REASONABLE VALUE FOR THIS JOB. | | | | | | 2.PROVIDE A SITE PLAN SHOWING LOCATION OF PROPOSED | | | WORK, FBC*106. | | | | | | 3.SHOW ELEVATION OF CONCRETE IN RELATION TO FINISHED | | | FLOOR ELEVATION FOR THE HOUSE, FBC R301, FBC R401.3. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2009-06-22 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-06-22 |
Time |
13:38 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-06-22 |
Time |
13:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2009-03-24 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-03-24 |
Time |
11:59 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-03-24 |
Time |
10:11 |
Sent To |
M |
|
| Notes |
| 2009-03-24 11:58:37 | | | | | | | | | | THIS REVIEW WAS DONE UNDER THESE CODE CYCLES: | | | | | | THE 2004 FLORIDA RESIDENTIAL BUILDING CODE, 2007 | | | REVISIONS, 2005 NEC, 2004 FBC AS AMENDED, CHAPTER 1.AND | | | FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | | | | 1} THE EQUIPMENT GROUND BETWEEN THE METER AND | | | DISCONNECT ON THE RISER DIAGRAM CREATES A PARALLEL PATH | | | TO GROUND WITH THE NEUTRAL AND MUST BE REMOVED. AN | | | ISOLATED NEUTRAL AND EQUIPMENT GROUND ARE TO BE RAN | | | FROM THE FIRST MEANS OF DISCONNECT. 250.6. | | | | | | 2} THERE ARE NO FEEDER CONDUCTORS SHOWN BETWEEN PANEL | | | "A" AND PANEL "B" ON THE RISER DIAGRAM.THERE IS NO OCP | | | OR CIRCUITS IN PANEL "A" FOR THIS FEED. INDICATE HOW | | | PANEL "B" IS FED, SUBMIT CONDUIT AND CONDUCTOR SIZES. | | | SEE 250.122 AND 215.5 NEC 2005. | | | | | | 3} THERE ARE TWO CIRCUITS (11,13) FOR SMALL APPLIANCE | | | ON THE SCHEDULE BUT 3 ARE CALCULATED, SEE 4500 WATTS | | | FOR THESE CIRCUITS.408.4 NEC | | | | | | 4} THE DISCONNECT FOR ACU #1IS IN VIOLATION OF 110.26 | | | CLEARANCE REQUIREMENTS IT IS SHOWN ON THE PLAN. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2008-10-15 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-10-15 |
Time |
11:46 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-10-15 |
Time |
08:45 |
Sent To |
B |
|
| Notes |
| 2008-10-15 11:10:39 | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2004 | | | RESIDENTIAL BUILDING CODE, 2005 NEC, 2004 FBC CHAPTER 1 | | | AS AMENDED AND FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | | | | ALL COMMENTS RELATE TO SHEET A-4, UNLESS OTHERWISE | | | NOTED. | | | | | | 1} THE 2005 NEC WAS ADOPTED BY THE FLORIDA LEGISLATURE | | | EFFECTIVE 8 DECEMBER 2006. THE APPLICATION FOR THIS | | | PROJECT WAS AFTER THAT DATE AND THE PLANS ARE SUBJECT | | | TO THAT CODE. PLEASE CHANGE ALL NOTES TO REFLECT THIS | | | CHANGE THE REFERENCED NEC ON SHEET A-4 IS 2002.NOTE | | | RELOCATE THE NOTES AND SYMBOLS LEGEND AS THEY ARE | | | PARTIALLY CUT OFF AS ARE THE CIRCUIT NUMBERS IN PANEL | | | "B". NOTES #4, 6, AND 8 ON SHEET A-2 SHOULD ALSO BE | | | LOCATED ON SHEET A-4 | | | | | | 2} THE GROUNDING ELECTRODE CONDUCTOR MUST COMPLY WITH | | | 250.52(A)(3) FOR FOOTER STEEL SINCE AVAILABLE. | | | | | | 3} AN EQUIPMENT GROUNDING CONDUCTOR MUST BE INSTALLED | | | FROM THE FIRST MEANS OF DISCONNECT TO THE PANEL PER | | | 250.118, SIZED PER 250.122. | | | | | | 4} THERE APPEARS TO BE 10 SMALL APPLIANCE CIRCUITS IN | | | PANEL"B", CLARIFY THE PANEL SCHEDULE PER 408.4 NEC. | | | | | | 5} PANEL "A", CIRCUITS #6,8 HAVE A #10 CONDUCTOR | | | PROTECTED WITH A 40 AMP OCP IN VIOLATION OF 310.16. | | | | | | 6} LOCATE THE WATER HEATER AND DISCONNECTING MEANS FOR | | | SAME ON THE PLAN PER 422.III. | | | | | | 7} RECEPTACLE SPACING MUST COMPLY WITH 210.52(A)(1) AND | | | 210.52(A)(2). 2005 NEC. SEE REVIEWED PLAN FOR | | | DEFICIENCIES. | | | | | | 8} SHOW THE LOCATION OF THE A/C EQUIPMENT ON THE PLAN | | | SO THAT COMPLIANCE WITH 110.26 CAN BE REMOVED. | | | | | | 9} THERE IS A POOL PUMP DISCONNECT SHOWN ON THE PLAN BY | | | THE A/C DISCONNECTS, BUT NO POOL EQUIPMENT IN THE PANEL | | | SCHEDULE OR LOAD CALCULATION.408.4, 220.82, 220.83. | | | | | | 10} INCLUDE THE ADDRESS OF THE PROJECT ON THE PLANS PER | | | 106.1.1 FBC AS AMENDED. | | | | | | 11} THE PERSON TAKING RESPONSIBILITY FOR THE DESIGN | | | MUST PRINT AND SIGN THEIR NAME TO SAME, ALL SHEETS, PER | | | 106.1.3.FBC. | | | | | | PLEASE REMOVE OLD SHEETS, INSERT NEW ONES, SUBMIT OLD | | | SHEETS TO EXPEDITE REVIEW AND SUBMIT WRITTEN RESPONSE | | | TO THE COMMENTS MADE IN THIS REVIEW. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | | | | | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2009-06-17 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2009-06-05 |
Time |
16:33 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2009-06-05 |
Time |
16:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2009-03-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-03-09 |
Time |
09:18 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-03-09 |
Time |
09:18 |
Sent To |
Z |
|
| Notes |
| 2009-03-09 09:18:36 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-09-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-09-26 |
Time |
08:56 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-09-26 |
Time |
08:56 |
Sent To |
Z |
|
| Notes |
| 2008-09-26 08:56:37 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-07-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-07-14 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-07-14 |
Time |
10:34 |
Sent To |
B |
|
| Notes |
| 2008-07-14 10:35:33 | TO "MISC" BOX#2 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-07-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-07-24 |
Time |
08:22 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-07-09 |
Time |
11:05 |
Sent To |
|
|
| Notes |
| 2008-07-09 11:05:31 | TO "Z" BOX |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
P |
Date |
2009-06-24 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2009-06-24 |
Time |
17:12 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2009-06-24 |
Time |
17:12 |
Sent To |
|
|
| Notes |
| 2009-06-24 17:16:25 | ***LANDSCAPE APPROVED WITH PROVISO*** | | | | | | PLANTING IN RIGHT-OF-WAY SHALL BE APPROVED BY | | | ENGINEERING. | | | IRRIGATION SHALL BE PROVIDED IN RIGHT-OF-WAY. | | | | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
2009-03-18 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2009-03-18 |
Time |
16:48 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2009-03-18 |
Time |
16:00 |
Sent To |
|
|
| Notes |
| 2009-03-18 16:41:59 | ***LANDSCAPE REVIEW FAILED*** | | | | | | 1. PLEASE RESPOND TO ALL COMMENTS IN WRITTEN FORMAT. | | | | | | 2. SUBMIT COST ESTIMATE THAT INCLUDES THE TOTAL COST OF | | | ALL LANDSCAPE MATERIALS AND LABOR. | | | | | | 3. PLEASE PROVIDE THE TABULATION REQUIRED TO COMPLY | | | WITH ARTICLE XIV OF THE ZONING AND LAND DEVELOPMENT | | | REGULATIONS, INCLUDING THE XERISCAPE POINTS. BASED UPON | | | THE OPEN SPACE, (4) SHADE OR FLOWERING TREES ARE | | | REQUIRED. | | | | | | 4. ALL GROUND LEVEL AIR CONDITIONING UNITS AND OTHER | | | MECHANICAL EQUIPMENT IS REQUIRED TO BE SCREENED. | | | | | | 5. ON THE LANDSCAPE PLAN, PLEASE IDENTIFY ALL | | | UTILITIES, EASEMENTS, OVERHANGING TREE CANOPIES FROM | | | NEIGHBORING PROPERTIES AND ANYTHING ELSE THAT MAY | | | INTERFERE WITH PROPOSED LANDSCAPING. | | | | | | 6. AN IRRIGATION PERMIT WILL BE REQUIRED. ALL PLANTED | | | AREA, INCLUDING THE RIGHT-OF-WAY, IS REQUIRED TO | | | RECEIVE 120% IRRIGATION COVERAGE. | | | | | | 7. PLEASE SHOW THE QUANTITY OF PLANTS IN EACH PLANT | | | BED. | | | | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT | | | KUSSNER @ (561) 822-1462. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2009-07-10 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2009-07-10 |
Time |
13:50 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2009-07-10 |
Time |
13:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2009-03-30 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2009-03-30 |
Time |
14:08 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2009-03-30 |
Time |
14:08 |
Sent To |
P |
|
| Notes |
| 2009-03-30 14:17:35 | PLAN DENIED | | | 1) PLEASE PROVIDE TWO FULL SETS OF ENERGY CALCULATIONS | | | AND LOAD CALCULATIONS WITH THE PLANS . | | | 2) PLEASE SHOW LOCATION OF WATER HEATER ON MECHANICAL | | | PLANS TO CALCULATE COMBUSTION AIR . | | | 3) PLEASE SHOW BATHROOM EXHAUST FANS ON THE MECHANICAL | | | PLANS AND THE TERMINATION OF THE EXHAUST DUCT . | | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2008-10-10 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-10-10 |
Time |
14:32 |
Rev Time |
0.40 |
| Received By |
tgordon |
Date |
2008-10-10 |
Time |
14:24 |
Sent To |
P |
|
| Notes |
| 2008-10-10 14:32:07 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | *** DENIED *** | | | | | | 1) ENERGY CALCULATIONS NEED TO BE ON FORM 600A-04R, PER | | | 2004 FBC 13-600.3.A (12-8-06 REVISION). | | | | | | 2) ENERGY CALCULATIONS NEED TO BE SIGNED BY OWNER/AGENT | | | ALSO, PER 2004 FBC 13-103.3. | | | | | | 3) SUBMIT COOLING LOAD CALCULATIONS, PER 2004 FBC | | | 13-607.1.ABC.1. | | | | | | 4) SUBMIT MECHANICAL (A/C) PLANS, PER 2004 WPB AMEND. | | | 106.3.5.4 (10). | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2009-06-17 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-06-17 |
Time |
08:27 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-06-16 |
Time |
16:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2009-03-31 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-03-31 |
Time |
13:40 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-03-31 |
Time |
13:40 |
Sent To |
B |
|
| Notes |
| 2009-03-31 14:14:40 | DENIED | | | REFERENCE: | | | FBC-2004 RESIDENTIAL | | | FBC-2004 PLUMBING | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1. ALL SHTS WITH TURQUOISE CONSULTING INC. THE | | | CERTIFICATE OF AUTHORIZATION NUMBER IS REQUIRED IN THE | | | TITLE BLOCK OF EACH SHEET. FAC 61G15-23/002(2) & FS | | | 471.025. | | | | | | 2. SHT A4.0 SANITARY RISER DIAGRAM. THE AUTOMATIC | | | CLOTHES WASHER FIXTURE DRAIN SHALL CONNECT TO A BRANCH | | | DRAIN OR DRAINAGE STACK A MINIMUM OF 3 INCHES IN | | | DIAMETER. SECTION 406.3. | | | PLEASE CORRECT ON RISER DIAGRAM. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2008-10-10 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-10-13 |
Time |
16:30 |
Rev Time |
3.00 |
| Received By |
mperson |
Date |
2008-10-10 |
Time |
16:30 |
Sent To |
E |
|
| Notes |
| 2008-10-10 16:57:56 | PLUMBING PLAN REVIEW: | | | DENIED: | | | | | | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | | PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE. | | | | | | 1. CLEARLY INDICATE THE CODE CYCLE ON THE PLANS. PER | | | CITY OF WPB AMENDMENTS TO CHAPTER 1, SECTION 106.5 | | | RETENTION OF CONSTRUCTION DOCUMENTS. | | | THE CURRENT CODE CYCLE FOR THE PLANS IS "FBC-2004 WITH | | | 2007 REVISIONS". | | | | | | 2. DECLARE THE LEVEL OF ALTERATION. PER FBC-2004 | | | EXISTING BUILDING CHAPTER 3. | | | | | | 3. NOTE: FROM THE RESUBMITTAL FORM AND WHATS BEING | | | INDICATED ON SHEET A-2, IT APPEARS THE ENTIRE RESIDENCE | | | HAS A NEW FLOOR PLAN LAYOUT. PLEASE PROVIDE AN EXISTING | | | FLOOR PLAN LAYOUT OF THE RESIDENCE THAT CLEARLY | | | INDICATES EXACTLY WHERE ALL THE EXISTING PLUMBING | | | FIXTURES WERE LOCATED. PER FBC-2004 CHAPTER 1, (W.P.B. | | | AS AMENDED SECTION 106.1.2 ADDITIONAL DATA. | | | | | | 4. SHEET A-3 TYPICAL PLUMBING ISOMETRIC: PLEASE KNOW | | | THAT THE SUBMITTED SANITARY ISOMETRIC RISER DIAGRAM | | | DOES NOT REFLECT THE FLOOR PLAN. THE TUB AND LAVATORY | | | IN ONE OF THE 2ND FLOOR BATHROOMS ARE BEING INDICATED | | | IN THE WRONG LOCATION. AT A MINIMUM THE SANITARY RISER | | | DIAGRAM SHALL REFLECT THE FLOOR PLAN. PLEASE PROVIDE A | | | FLAT LINE DRAWING OF THE PROPOSED SANITARY PLUMBING ON | | | THE FLOOR PLAN AND CORRELATE THE SANITARY RISER DIAGRAM | | | WITH IT. PER FBC-2004 PLUMBING CODE SECTION 701.1 AND | | | 901.1 SCOPE AND FBC-2004 CHAPTER 1, (W.P.B. AS AMENDED) | | | SECTION 106.1.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | 5. SHEET A-3 TYPICAL PLUMBING ISOMETRIC: PLEASE CORRECT | | | THE FOLLOING ITEMS ON THE SANITARY ISOMETRIC COMPLIANT | | | WITH THE FBC-2004 PLUMBING CODE SECTIONS. | | | | | | A} THE WATER CLOSETS ARE BEING INDICATED WITH TRAPS | | | BEING INSTALLED FOR THEM. PLEASE KNOW THAT WATER | | | CLOSETS HAVE INTEGRAL TRAPS AND THAT FIXTURES SHALL NOT | | | BE DOUBLE TRAPPED. PER SECTION 1002.1 FIXTURE TRAPS. | | | | | | B} A LOT OF THE FIXTURES ARE BEING INDICATED AS HAVING | | | "S" TRAPS. PLEASE KNOW THAT "S" TRAPS ARE PROHIBITED. | | | PLEASE REFERENCE THE RED CIRCLED PROHIBITED "S" TRAPS | | | ON THE ISOMETIC AND REVISE. PER SECTION 1002.3 | | | PROHIBITED TRAPS. | | | | | | C} FIXTURE VENTS ARE BEING INDICATED AT THE FIXTURE | | | TRAP INLET. HOW WILL THESE FIXTURES DRAIN WITH A VENT | | | IN THEIR FIXTURE TRAP INLET? PLEASE KNOW THAT THE VENT | | | FOR THE FIXTURE DRAIN SHALL CONNECT ABOVE THE WEIR OF | | | THE FIXTURE TRAP BEING VENTED. PER SECTION 906.2 | | | VENTING OF FIXTURE DRAINS. | | | | | | D} PLEASE CLARIFY THE VENT TERMINATIONS OF THE STACK | | | VENT AS TERMINATING OUTDOORS TO OPEN AIR, SUCH AS VENT | | | THRU ROOF (V.T.R.). PER SECTION 903.3 VENT TERMINATION. | | | | | | E} THE PROPOSED 2ND FLOOR SANITARY PLUMBING IS BEING | | | INDICATED AS CONNECTING TO THE WASHING MACHINE FIXTURE | | | DRAIN INLET. HOW WILL THE WASHING MACHINE DRAIN? PLEASE | | | KNOW THAT THE PROPOSED 2ND FLOOR PLUMBING FIXTURES WILL | | | REQUIRE A SEPERATE DRAINAGE STACK. PER SECTION 908.3 | | | CONNECTION AT DIFFERENT LEVELS. | | | | | | F} NOTE: IF THE PROPOSED DRAINAGE STACK FOR THE 2ND | | | FLOOR FLOOR PLUMBING IS LOCATED BY THE WASHING MACHINE | | | PLEASE KNOW THAT VENTS WILL BE REQUIRED FOR THE 1ST | | | FLOOR L.T. AND KITCHEN FIXTURES. PER SECTION 901.2.1 | | | VENTING REQUIRED. | | | | | | G} NOTE: 2ND FLOOR NEW 3" WASTE LINE BY THE LAV. IS | | | BEING INDICATED WITH A DEAD END. PLEASE KNOW THAT IN | | | THE INSTALLATION OF ANY PART OF A DRAINAGE SYSTEM, DEAD | | | ENDS SHALL BE PROHIBITED. PER SECTION 704.5 DEAD ENDS. | | | | | | H} NOTE: CLEANOUTS ARE REQUIRED FOR THE SANITARY SYSTEM | | | AND THEY SHALL BE LOCATED PER THE FOLLOWING CODE | | | SECTIONS. | | | | | | SECTION 708.3.4 BASE OF STACK. A CLEANOUT | | | SHALL BE PROVIDED AT THE BASE OF EACH | | | WASTE OR SOIL STACK | | | | | | SECTION 708.3.5 BUILDING DRAIN AND BUILDING SEWER | | | JUNCTION. THERE SHALL BE A TWO-WAY CLEANOUT NEAR THE | | | JUNCTION OF THE BUILDING DRAIN AND THE BUILDING SEWER. | | | | | | 6. ALL PLANS, SPECIFICATIONS, AND ACCOMPANYING DATA | | | BEING FILED FOR PUBLIC RECORD SHALL CONTAIN THE PRINTED | | | NAME OF THE RESPONSIBLE PERSON WITH THE ORIGINAL | | | SIGNATURE AND DATE ON SUCH INFORMATION. PER SECTION | | | *106.3.4.3. | | | IF THE DESIGN PROFESSIONAL IS AN ARCHITECT OR ENGINEER, | | | THEN HE OR SHE SHALL AFFIX HIS OR HER OFFICIAL SEAL, | | | SIGNATURE AND DATE TO SAID DRAWINGS, PER FLORIDA | | | STATUTES 481 AND 471 RESPECTIVELY. | | | NOTE: ONLY TITLE SHEET CONTAINED THE PRINTED NAME AND | | | ORIGINAL SIGNATURE OF THE RESPOSIBLE PERSON. | | | | | | ********IMPORTANT INFORMATION******** | | | WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE | | | OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW | | | PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | **PLEASE KNOW THAT ADDITIONAL COMMENTS MAY APPEAR ON | | | THE NEXT PLUMBING PLAN REVIEW DUE TO THE SANITARY | | | ISOMETRIC RISER DIAGRAM BEING REVISED. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | PHONE= (561) 805-6730 | | | FAX= (561) 805-6731 | | | E-MAIL= [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2009-06-25 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2009-06-25 |
Time |
11:11 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2009-06-24 |
Time |
09:14 |
Sent To |
|
|
| Notes |
| 2009-06-25 11:11:26 | PLACED BACK ON R5 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2009-03-17 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2009-03-17 |
Time |
18:45 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2009-03-17 |
Time |
18:33 |
Sent To |
L |
|
| Notes |
| 2009-03-17 18:45:29 | PLANNING AND ZONING DEPT: ***ZONING FAILED*** | | | | | | 1. PLEASE PROVIDE ALL RESPONSES IN WRITING. | | | | | | 2. INDICATE SETBACK DIMENSIONS FROM PROPOSED MECHANICAL | | | (A/C AND POOL) EQUIPMENT TO ALL PROPERTY LINES. | | | PURSUANT THE CITY OF WEST PALM BEACH ZONING AND LAND | | | DEVELOPMENT REGULATIONS (ZLDR), SECTION 94-305(B)(4): | | | MECHANICAL EQUIPMENT MAY NOT PROJECT MORE THAN 4 FEET | | | INTO A REQUIRED SETBACK. | | | | | | 3. INDICATE OVERHANG DIMENSIONS OF THE PROPOSED | | | IMPROVEMENTS. PURSUANT TO THE CITY OF WEST PALM BEACH | | | ZONING AND LAND DEVELOPMENT REGULATIONS (ZLDR), SECTION | | | 94-305(B): OVERHANGS SHALL NOT PROJECT MORE THAN THREE | | | (3) FEET INTO A REQUIRED SETBACK. | | | | | | 4. THE PROPOSED DRIVEWAY SHALL BE SUBMITTED UNDER | | | SEPARATE PERMIT. ADDITIONALLY, A RIGHT-OF-WAY PERMIT | | | WILL NEED TO BE ACQUIRED FROM THE CITY'S ENGINEERING | | | DEPARTMENT (561.494.1040), FOR THE PROPOSED APPROACH | | | EXTENSION. | | | | | | 6. AS THE VALUE OF THE PROPOSED PROJECT INCREASED FROM | | | $40,000 TO $75,000, AND EXCEEDS 50% OF THE STRUCTURE'S | | | VALUE (LISTED AS "IMPROVEMENT VALUE" WITH THE P.B.C. | | | PROPERTY APPRAISER'S OFFICE), LANDSCAPING SHALL BE IN | | | COMPLIANCE WITH ALL APPLICABLE REGULATIONS FOUND IN | | | ARTICLE XIV OF THE ZLDR, SECTIONS 94-442 AND 94-445 OF | | | THE ZLDR. | | | | | | NOTE: THE SUBMITTAL OF THE REQUESTED INFORMATION MAY | | | GENERATE ADDITIONAL COMMENTS. | | | | | | FOR ADDITIONAL INFORMATION, THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT | | | WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH | | | PLANNING DEPARTMENT WEBSITE AT | | | WWW.CITYOFWPB.COM/PLAN/INDEX.HTM. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | | CONTACT ME. | | | | | | MAGGIE CRUZ, ASSOCIATE PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: (561) 822-1444 OR (561) 805-6720 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2008-10-03 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2008-10-03 |
Time |
13:35 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2008-10-03 |
Time |
13:00 |
Sent To |
B |
|
| Notes |
| 2008-10-03 13:34:44 | ***ZONING FAILED*** | | | | | | 1. PLEASE PROVIDE ALL RESPONSES IN WRITING. | | | | | | 2. THE PROPOSED ADDITIONS EXCEED THE FRONT AND SIDE | | | MINIMUM PRINCIPAL STRUCTURE SETBACKS. PLEASE CORRECT. | | | NOTE: CITY OF WEST PALM BEACH ZONING AND LAND | | | DEVELOPMENT REGULATIONS (ZLDR), SECTION 94-74: SINGLE | | | FAMILY HIGH DENSITY (SF14) RESIDENTIAL DISTRICT - | | | MINIMUM SETBACKS FOR PRINCIPAL BUILDING ARE AS FOLLOWS: | | | | | | A. FRONT: 25 FEET; | | | | | | B. CORNER: 12.5 FEET; TEN FEET IF LOT IS LESS THAN 60 | | | FEET WIDE; | | | | | | C. REAR: 15 FEET OR TEN PERCENT OF DEPTH, WHICHEVER IS | | | LESS; | | | | | | D. SIDE: FIVE FEET MINIMUM, 15 FEET TOTAL. | | | | | | 3. INDICATE OVERHANG DIMENSIONS OF THE PROPOSED | | | ADDITION. PURSUANT TO THE ZLDR, SECTION 94-305(B): | | | OVERHANGS SHALL NOT PROJECT MORE THAN THREE (3) FEET | | | INTO A REQUIRED SETBACK. | | | | | | 4. IT APPEARS ON THE SITE PLAN THAT A WALKWAY IS BEING | | | PROPOSED. PURSUANT TO THE ZLDR, SECTION 94-482: | | | REQUIRED OFF-STREET PARKING SPACES FOR LESS THAN FOUR | | | RESIDENTIAL DWELLING UNITS SHALL BE LOCATED ON THE | | | PROPERTY ON WHICH THE UNITS ARE CONSTRUCTED. REQUIRED | | | PARKING MAY BE LOCATED IN A FRONT YARD; HOWEVER, THE | | | LESSER OF 1,000 SQUARE FEET OR 75 PERCENT OF THE FRONT | | | YARD AREA MUST BE LANDSCAPED. PARKING AREAS LOCATED IN | | | THE FRONT YARD SHALL BE SURFACED WITH A SMOOTH, | | | NONDUSTING SURFACE IN COMPLIANCE WITH SUBSECTION | | | 33-485(E). IT SHALL BE A VIOLATION OF THIS CHAPTER TO | | | PARK ON ANY UNPAVED AREAS AS DESCRIBED IN THIS ARTICLE. | | | | | | PLEASE INDICATE SQUARE FOOTAGE OF ALL IMPERMEABLE | | | SURFACES (EXISTING AND PROPOSED) LOCATED WITHIN THE | | | FRONT YARD (FROM FRONT PROPERTY LINE TO THE FRONT | | | BUILDING FACADE). | | | | | | 5. INDICATE SETBACK DIMENSIONS FROM ANY PROPOSED A/C | | | EQUIPMENT TO ALL PROPERTY LINES. PURSUANT TO THE ZLDR, | | | SECTION 94-305(B)(4): MECHANICAL EQUIPMENT MAY NOT | | | PROJECT MORE THAN FOUR (4) FEET INTO A REQUIRED | | | SETBACK. | | | | | | | | | | | | NOTE: THE SUBMITTAL OF THE REQUESTED INFORMATION MAY | | | GENERATE ADDITIONAL COMMENTS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | | CONTACT ME. | | | | | | MAGGIE CRUZ, ASSOCIATE PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: (561) 822-1444 OR (561) 805-6720 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2009-03-17 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2008-07-11 |
Time |
|
Rev Time |
|
| Received By |
mcruz |
Date |
2008-07-11 |
Time |
|
Sent To |
I |
|
| Notes |
| 2008-07-11 16:47:28 | NOTE - SETBACK OFF APPROXIMATELY 0.2 FEET, HOWEVER, | | | PURSUANT TO PERMIT #3378I OBTAINED ON 10/15/82, THE | | | OPEN CARPORT WAS LEGALLY CONVERTED TO A GARAGE. |
|
|