| Plan Review Stops For Permit 08070127 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
10 |
Status |
P |
Date |
2009-01-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-01-07 |
Time |
13:31 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2009-01-07 |
Time |
13:31 |
Sent To |
PC |
|
| Notes |
| 2009-01-07 13:33:56 | BUILDING PLAN REVIEW | | | PERMIT: 08070127 | | | ADD: 550 S ROSEMARY | | | CONT: ALLIANCE | | | TEL: (561)818-7777 | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVISION REVIEW SKETCH# 5& 6 | | | 8X11 & 11X17 | | | ACTION: REVIWED | | | 2 HR RATED VESTIBULE ASSEMBLY | | | | | | VESTIBULE IS PART OF A 2HR RATED STAIRWELL ENCLOSURE | | | AND TO COMPLY WITH 1019.1. ( ALTERNATE MEANS AND | | | MATERIALS) | | | REVIEWED BY ITERUM B.O. ROBERT BROWN | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)805-6731 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
9 |
Status |
F |
Date |
2009-01-04 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-01-04 |
Time |
08:49 |
Rev Time |
0.50 |
| Received By |
jwitmer |
Date |
2009-01-04 |
Time |
08:49 |
Sent To |
|
|
| Notes |
| 2009-01-04 09:15:42 | IMPROV CITY PLACE | | | BUILDING PLAN REVIEW | | | PERMIT: 08070127 | | | ADD: 550 S ROSEMARY AVE SUITE# 250 | | | CONT: ALLIANCE CONTRACTING | | | TEL: (561)856-6655 | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVISION REVIEW #8 1/2" X 11" FILLING OF TRASH CHUTE | | | OPENING | | | ACTION: DENIED | | | | | | 1) THE DESIGNER OF RECORD ARCHITECT JORDON SOPOURN DOES | | | NOT INDICATE ANY TRASH CHUTE OPENINGS ON THE FLOOR | | | PLANS A120.1-A120.4, PLEASE PROVIDE LOCATION AND SIZE | | | OF OPENING. THE OTHER ISSUE | | | IS THE 8 1/2" X 11" DETAIL HAS NOT BEEN REVIEWED BY THE | | | DESIGNER OF RECORD. | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC... | | | | | | 2) 61G15-23.002(2) FL. ADMIN. CODE. PLANS SIGNED & | | | SEALED BY A PROFESSIONAL ENGINEER SHALL INCLUDE EITHER | | | THE: NAME, ADDRESS AND LICENSE NUMBER OF THE ENGINEER | | | OR, IF PRACTICING AS A DULY AUTHORIZED ENGINEERING | | | BUSINESS THERE NAME AND LICENSE NUMBER OF THE ENGINEER | | | AND THE NAME, ADDRESS AND CERTIFICATE OF AUTHORIZATION | | | NUMBER OF THE ENGINEERING BUSINESS THROUGH WHICH THE | | | ENGINEER IS PRACTICING (471.025 F.S. AND 471.023 F.S.). | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)805-6731 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
F |
Date |
2009-01-04 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-01-04 |
Time |
08:22 |
Rev Time |
0.50 |
| Received By |
jwitmer |
Date |
2009-01-04 |
Time |
08:22 |
Sent To |
|
|
| Notes |
| 2009-01-04 08:48:48 | BUILDING PLAN REVIEW | | | PERMIT: 08070127 | | | ADD: 550 S ROSEMARY AVE SUITE# 250 | | | CONT: ALLIANCE CONTRACTING | | | TEL: (561)856-6655 | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVISION REVIEW # 4 SHEET A130.4 | | | ACTION: DENIED | | | | | | 1) SHEET A130.4 INDICATES A NEW BAR AND NEW ROLL DOWN | | | DOOR BY OVERHEAD DOOR CO. THE CONTRACTOR HAS NOT | | | SUBMITTED ANY PRODUCT APPROVAL FOR THIS OPENING, PLEASE | | | SEE REQUIREMENTS FOR NEW DOOR REVIEW. FL BLD CODE | | | 1609.6.2.2 COMPONENTS & CLADDING, PROVIDE 2 COPIES, | | | 3 IF THRESHOLD OR RESIDENT INSPECTOR OF PRODUCT TESTING | | | REPORTS, MISSING REPORTS ARE AS FOLLOWS: ROLL DOWN DOOR | | | BY OVERHEAD DOOR CO. | | | | | | 1A) 1603.1.4 WIND DESIGN DATA. | | | THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL | | | BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE | | | DESIGN OF THE LATERAL-FORCE-RESISTING SYSTEM OF THE | | | BUILDING: | | | | | | 1. BASIC WIND SPEED (3-SECOND GUST), MILES PER HOUR | | | (KM/HR). | | | 2. WIND IMPORTANCE FACTOR, I W , AND BUILDING | | | CLASSIFICATION FROM TABLE 1604.5 OR TABLE 6-1, ASCE 7 | | | AND BUILDING CLASSIFICATION IN TABLE 1-1, ASCE 7. | | | 3. WIND EXPOSURE, IF MORE THAN ONE WIND EXPOSURE IS | | | UTILIZED, THE WIND EXPOSURE AND APPLICABLE WIND | | | DIRECTION SHALL BE INDICATED. | | | 4. THE APPLICABLE ENCLOSURE CLASSIFICATIONS AND, IF | | | DESIGNING WITH ASCE 7, INTERNAL PRESSURE COEFFICIENT. | | | 5. COMPONENTS AND CLADDING. THE DESIGN WIND PRESSURES | | | IN TERMS OF PSF (KN/M 2 ) TO BE USED FOR THE SELECTION | | | OF EXTERIOR COMPONENTS AND CLADDING MATERIALS NOT | | | SPECIFICALLY DESIGNED BY THE REGISTERED DESIGN | | | PROFESSIONAL. | | | | | | 1B) 1609. 6.2.2 COMPONENTS AND CLADDING. | | | | | | 1C) 1609.1.4 PROTECTION OF OPENINGS IN WIND-BORNE | | | DEBRIS REGIONS, EXTERIOR GLAZING THAT RECEIVES POSITIVE | | | PRESSURE IN THE LOWER 60 FEET (18.3 M) IN BUILDINGS | | | SHALL BE ASSUMED TO BE OPENINGS AND THE BALANCE OF | | | GLAZED OPENINGS IN THE REST OF THE BUILDING SHALL BE | | | ASSUMED TO BE ZERO UNLESS SUCH GLAZING THAT RECEIVES | | | POSITIVE PRESSURE IS IMPACT RESISTANT OR PROTECTED WITH | | | AN IMPACT RESISTANT COVERING MEETING THE REQUIREMENTS | | | OF SSTD 12, ASTM E 1886 AND ASTM E 1996, OR MIAMI-DADE | | | TAS 201, 202 AND 203 REFERENCED THEREIN AS FOLLOWS: 1. | | | GLAZED OPENINGS LOCATED WITHIN 30 FEET (9.1 M) OF GRADE | | | SHALL MEET THE REQUIREMENTS OF THE LARGE MISSILE TEST. | | | 2. GLAZED OPENINGS LOCATED MORE THAN 30 FEET (9.1 M) | | | ABOVE GRADE SHALL MEET THE PROVISIONS OF THE SMALL | | | MISSILE TEST. | | | | | | 1D) ( IF APPLICABLE) PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 ARE REQUIRED | | | TO COMPLY WITH THE FLORIDA PRODUCT APPROVAL SYSTEM. FOR | | | INFORMATION PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH STATEWIDE | | | APPROVAL ARE REQUIRED TO BE SUBMITTED WITH A COVER | | | SHEET THAT LISTS THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE STATEWIDE APPROVAL, | | | SUBMIT AN APPLICATION FOR LOCAL PRODUCT APPROVAL OR | | | SITE SPECIFIC FORM PER RULE 9B-72. SEE ATTACHMENT. | | | WWW.FLORIDABUILDING.ORG | | | | | | 1E) WPB ADMIN CODE 106.3* PRODUCT APPROVALS. THOSE | | | PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)805-6731 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
P |
Date |
2009-01-04 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-01-04 |
Time |
07:57 |
Rev Time |
1.50 |
| Received By |
jwitmer |
Date |
2009-01-04 |
Time |
07:08 |
Sent To |
|
|
| Notes |
| 2009-01-04 08:22:00 | REVISION # 4 DATED 12-01-2008 | | | SHEETS REVIEWED: OK | | | A120.2, A120.4, A130.2, A180.1, A180.4 & A500.1 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
F |
Date |
2009-01-02 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-01-02 |
Time |
09:58 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2009-01-02 |
Time |
09:58 |
Sent To |
PC |
|
| Notes |
| 2009-01-02 10:16:29 | BUILDING PLAN REVIEW | | | PERMIT: 08070127 | | | ADD: 550 S ROSEMARY | | | CONT: ALLIANCE | | | TEL: (561)818-7777 | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVISION REVIEW DATED DEC. 5/2008 | | | 8X11 | | | ACTION: DENIED | | | 2 HR RATED VESTIBULE ASSEMBLY | | | | | | 1) 106.1.2 ADDITIONAL INFORMATION REQUIRED. PLANS FAIL | | | TO INDICATE THE LOCATION OF THIS VESTIBULE. SPOKE WITH | | | ARCHITECT JORY SOPOURN III ABOUT THIS REVISION, AND | | | WHAT WILL BE REQUIRED | | | FOR THE CITY TO ACCEPT THE DETAIL UNDER SECTION 104.11 | | | ALTERNATE MATERIALS, DESIGN AND METHODS OF CONSTRUCTION | | | AND EQUIPMENT, APPROVED BY THE INTERUM BUILDING | | | OFFICIAL ROBERT BROWN. | | | | | | A) PROVIDE ADDITIONAL INFORMATION WHEREAS WHERE EACH OF | | | THE AREAS ON THE PLAN IS LOCATED, STAIRWELL, ABOVE | | | CEILING AND OR IMPROV TENANT SPACE. | | | | | | B) PROVIDE A FULL HEIGHT DETAIL WITH CEILING OR DECK | | | ABOVE TO TENANT FLOOR SPACE, INDICATE CEILING LEVEL, | | | UNDERSTOOD THAT THE DRYWALL OF THE ENCLOSURE DOES NOT | | | EXTEND TO DECK ABOVE, THAT IS THE REASON FOR THE 2 HR | | | RATED CEILING WITHIN THE VESSTIBULE, NO FUEL LOADS TO | | | BE ABOVE THE RATED CEILING! | | | | | | C) PROVIDE A FLOOR PLAN INDICATING THE LOCATION OF THE | | | REVISON FOR CLARIFICATION. | | | | | | VESTIBULE IS PART OF A 2HR RATED STAIRWELL ENCLOSURE | | | AND TO COMPLY WITH 1019.1. ( ALTERNATE MEANS AND | | | MATERIALS) | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)805-6731 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2008-11-12 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-11-12 |
Time |
14:14 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2008-11-12 |
Time |
14:14 |
Sent To |
|
|
| Notes |
| 2008-11-12 14:16:37 | REVISION: | | | SK-1 BAR JOIST- DETAILS AT POINT LOADING | | | SK-2 MASONARY OPENING DETAIL | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2008-10-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-10-07 |
Time |
10:42 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2008-10-07 |
Time |
10:42 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2008-09-26 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-09-26 |
Time |
14:02 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2008-09-26 |
Time |
14:01 |
Sent To |
|
|
| Notes |
| 2008-09-26 14:15:14 | | | | BUILDING PLAN REVIEW | | | PERMIT: 08070127 | | | ADD: 550 S ROSEMARY # 250 | | | CONT: ALLIANCE | | | TEL: (561)856-6655 | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW | | | ACTION:REVIEWED | | | | | | | | | | | | BUILDING PROVISOS: | | | 1) NEEDS NOC TO BE RECORDED BEFORE FIRST INSPECTION | | | | | | 2) THIRD SET OF PLANS ARE REQUIRED FOR THE THRESHOLD | | | INSPECTOR WILL BE IN THE BUILDING DEPARTMENT | | | MONDAY 9-28-08 FOR REVIEW AND STAMPING | | | | | | 3) THRESHOLD BUILDING MEETING WITH KEN CONRAD THE | | | THRESHOLD ENGINEER & INSPECTOR | | | WILL TAKE PLACE MONDAY 9-29-08 | | | | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2008-09-10 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-09-10 |
Time |
09:30 |
Rev Time |
1.66 |
| Received By |
jwitmer |
Date |
2008-09-10 |
Time |
09:30 |
Sent To |
|
|
| Notes |
| 2008-09-10 09:37:55 | BUILDING REVIEW | | | PERMIT: 08070127 | | | ADD: 550 S ROSEMARY # 250 | | | CONT: ALLIANCE | | | TEL: (561)856-6655 | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | SEPT. 10,2008 | | | | | | 2ND REVIEW | | | ACTION: DENIED | | | | | | 1A) INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE | | | INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | 1B) INFORMATIONAL: PLEASE SUBMIT (3) OF ALL SURVEYS, | | | PLANS, REPORTS, REVISIONS , PRODUCT APPROVALS AND OR | | | SUBMITTALS FOR REVIEW FOR PERMIT. YOUR PROJECT | | | CONSIDERED A THRESHOLD BUILDING REQUIRING A THRESHOLD | | | INSPECTOR THEN (3) THREE SETS OF ALL SAID DOCUMENTS | | | WILL BE REQUIRED FOR PERMIT ISSUANCE. 106.1* /2004 | | | SUBMITTAL DOCUMENTS WEST PALM BEACH ADMINISTRATIVE | | | CODE. | | | | | | 1C) ) INFORMATIONAL FL S S 713.13 NOTICE OF | | | COMMENCEMENT, TO BE FILED WITH THE CLERK OF THE COURT. | | | NOTE: 713.13(2) IF THE WORK DESCRIBED IN THE NOTICE OF | | | COMMENCEMENT IS NOT ACTUALLY COMMENCED WITHIN 90 DAYS | | | AFTER THE RECORDING THEREOF, SUCH NOTICE IS NULL & | | | VOID. NOTE: 713.13(6) THE POSTING OF THE NOTICE OF | | | COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE THE FIRST | | | INSPECTION. | | | | | | 2) SECOND REQUEST, THRESHOLD INSPECTION PLAN FL S. S. | | | 553.71(7) " THRESHOLD BUILDING" MEANING ANY BUILDING | | | WHICH IS GREATER THAN (3) STORIES OR 50 FT IN HEIGHT, | | | OR WHICH HAS AN ASSEMBLY OCCUPANCY CLASSIFICATION AS | | | DENIED IN THE FLORIDA BUILDING CODE WHICH EXCEEDS 5,000 | | | SQ FT IN AREA AND AN OCCUPANT CONTENT OF GREATER THAN | | | 500 PERSONS. | | | | | | 2A) SECOND REQUEST, 105.13.1 THE ENFORCING AGENCY SHALL | | | REQUIRE A SPECIAL INSPECTOR TO PERFORM STRUCTURAL | | | INSPECTIONS ON A THRESHOLD BUILDING PURSUANT TO A | | | STRUCTURAL INSPECTION PLAN PREPARED BY THE ENGINEER OF | | | RECORD. THE STRUCTURAL INSPECTION PLAN MUST BE | | | SUBMITTED TO THE ENFORCING AGENCY PRIOR TO THE ISSUANCE | | | OF A BUILDING PERMIT FOR THE CONSTRUCTION OF A | | | THRESHOLD BUILDING. THE PURPOSE OF THE STRUCTURAL | | | INSPECTION PLAN IS TO PROVIDE SPECIFIC INSPECTION | | | PROCEDURES AND SCHEDULES SO THAT THE BUILDING CAN BE | | | ADEQUATELY INSPECTED FOR COMPLIANCE WITH THE PERMITTED | | | DOCUMENTS. | | | | | | 2B) SECOND REQUEST, THRESHOLD INSPECTOR WPB AMENDMENT | | | 105.13.6. W.P.B. CONSTRUCTION SERVICES DEPARTMENT | | | REQUEST FOR THRESHOLD BUILDINGS A SPECIAL INSPECTOR AS | | | REQUIRED BY FL S S 553.79(5) FLORIDA STATUTES TO THE | | | MINIMUM INSPECTIONS REQUIRED BY THIS CODE. CONTACT | | | JERALD SMITH MANAGER OF THE SPECIAL INSPECTOR PROGRAM | | | AT (561)805-6667 FOR FURTHER INFORMATION BEFORE THE | | | PERMIT MAY BE ISSUED. THE THRESHOLD INSPECTOR FORMS ARE | | | STILL ATTACHED TO THE FIRST ROUND OF BUILDING COMMENTS. | | | | | | 2C) SECOND REQUEST, I COULD NOT LOCATE THE REQUIRED FL | | | S S 633 STATEMENT, IT USUALLY IS LOCATED IN EITHER THE | | | COVER PAGE WITH GENERAL INFORMATION OR PROJECT | | | INFORMATION OR ON THE LIFE SAFETY SHEET A120.1. | | | THRESHOLD BUILSING, REQUIRED STATEMENT, W.P.B. | | | AMENDMENT 105.13.4.4 ALL PLANS FOR THE BUILDING WHICH | | | ARE REQUIRED TO BE SIGNED AND SEALED BY THE ARCHITECT | | | OR ENGINEER OF RECORD CONTAIN A STATEMENT THAT, TO THE | | | BEST OF THE ARCHITECT'S PR ENGINEER'S KNOWLEDGE, THE | | | PLANS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE | | | FIRE-SAFETY STANDARDS AS DETERMINED BY THE LOCAL | | | AUTHORITY IN ACCORDANCE WITH THIS SECTION AND 633 | | | FLORIDA STATUTE. | | | | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-07-23 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-07-23 |
Time |
07:12 |
Rev Time |
6.50 |
| Received By |
jwitmer |
Date |
2008-07-23 |
Time |
07:12 |
Sent To |
|
|
| Notes |
| 2008-07-23 07:18:39 | BUILDING PLAN REVIEW | | | PERMIT: 08070127 | | | ADD: 550 S ROSEMARY # 250 | | | CONT: ALLIANCE | | | TEL: (561)856-6655 | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW | | | ACTION: DENIED | | | | | | 1A) INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE | | | INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | 1B) INFORMATIONAL: PLEASE SUBMIT 2 OF ALL SURVEYS, | | | PLANS, REPORTS, REVISIONS , PRODUCT APPROVALS AND OR | | | SUBMITTALS FOR REVIEW FOR PERMIT. IF YOUR PROJECT WILL | | | REQUIRE A RESIDENT INSPECTOR OR IF YOUR PROJECT IS A | | | THRESHOLD BUILDING REQUIRING A THRESHOLD INSPECTOR THEN | | | (3) THREE SETS OF ALL SAID DOCUMENTS WILL BE REQUIRED | | | FOR PERMIT ISSUANCE. 106.1* /2004 SUBMITTAL DOCUMENTS | | | WEST PALM BEACH ADMINISTRATIVE CODE. | | | | | | 1C) INFORMATIONAL 106.1.1* W.P.B. ADMINISTRATIVE | | | CODE/2004 DRAWINGS & SPECIFICATIONS SHALL CONTAIN | | | INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, AS TO | | | THE QUALITY OF MATERIALS, WHERE QUALITY IS ESSENTIAL TO | | | CONFORMITY WITH THE TECHNICAL CODES. SUCH INFORMATION | | | SHALL BE SPECIFIC TO THE TECHNICAL CODES "SHALL NOT BE | | | CITED AS A WHOLE OR IN PART, NOR THE TERM "LEGAL" OR | | | ITS EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC | | | INFORMATION". CONSTRUCTION DOCUMENTS SHALL BE | | | SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND | | | EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT | | | WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | | DETERMINED BY THE BUILDING OFFICIAL. | | | | | | 1D ) INFORMATIONAL FL S S 713.13 NOTICE OF | | | COMMENCEMENT, TO BE FILED WITH THE CLERK OF THE COURT. | | | NOTE: 713.13(2) IF THE WORK DESCRIBED IN THE NOTICE OF | | | COMMENCEMENT IS NOT ACTUALLY COMMENCED WITHIN 90 DAYS | | | AFTER THE RECORDING THEREOF, SUCH NOTICE IS NULL & | | | VOID. NOTE: 713.13(6) THE POSTING OF THE NOTICE OF | | | COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE THE FIRST | | | INSPECTION. | | | | | | 1E) INFORMATIONAL: PLANS SUBMITTED FOR PERMIT (FIRST | | | TIME REVIEW) AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO | | | THE 2004 FBC BUILDING WITH THE 2007 SUPPLEMENTS. | | | | | | 2) THRESHOLD INSPECTION PLAN FL S. S. 553.71(7) " | | | THRESHOLD BUILDING" MEANING ANY BUILDING WHICH IS | | | GREATER THAN (3) STORIES OR 50 FT IN HEIGHT, OR WHICH | | | HAS AN ASSEMBLY OCCUPANCY CLASSIFICATION AS DENIED IN | | | THE FLORIDA BUILDING CODE WHICH EXCEEDS 5,000 SQ FT IN | | | AREA AND AN OCCUPANT CONTENT OF GREATER THAN 500 | | | PERSONS. | | | | | | 2A) 105.13.1 | | | THE ENFORCING AGENCY SHALL REQUIRE A SPECIAL INSPECTOR | | | TO PERFORM STRUCTURAL INSPECTIONS ON A THRESHOLD | | | BUILDING PURSUANT TO A STRUCTURAL INSPECTION PLAN | | | PREPARED BY THE ENGINEER OF RECORD. THE STRUCTURAL | | | INSPECTION PLAN MUST BE SUBMITTED TO THE ENFORCING | | | AGENCY PRIOR TO THE ISSUANCE OF A BUILDING PERMIT FOR | | | THE CONSTRUCTION OF A THRESHOLD BUILDING. THE PURPOSE | | | OF THE STRUCTURAL INSPECTION PLAN IS TO PROVIDE | | | SPECIFIC INSPECTION PROCEDURES AND SCHEDULES SO THAT | | | THE BUILDING CAN BE ADEQUATELY INSPECTED FOR COMPLIANCE | | | WITH THE PERMITTED DOCUMENTS. | | | | | | 2B)THRESHOLD INSPECTOR | | | WPB AMENDMENT 105.13.6. W.P.B. CONSTRUCTION SERVICES | | | DEPARTMENT REQUEST FOR THRESHOLD BUILDINGS A SPECIAL | | | INSPECTOR AS REQUIRED BY FL S S 553.79(5) FLORIDA | | | STATUTES TO THE MINIMUM INSPECTIONS REQUIRED BY THIS | | | CODE. | | | CONTACT JERALD SMITH MANAGER OF THE SPECIAL INSPECTOR | | | PROGRAM AT (561)805-6667 FOR FURTHER INFORMATION BEFORE | | | THE PERMIT MAY BE ISSUED. | | | | | | 2C) THRESHOLD BUILSING, REQUIRED STATEMENT, | | | W.P.B. AMENDMENT 105.13.4.4 ALL PLANS FOR THE BUILDING | | | WHICH ARE REQUIRED TO BE SIGNED AND SEALED BY THE | | | ARCHITECT OR ENGINEER OF RECORD CONTAIN A STATEMENT | | | THAT, TO THE BEST OF THE ARCHITECT'S PR ENGINEER'S | | | KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE | | | APPLICABLE FIRE-SAFETY STANDARDS AS DETERMINED BY THE | | | LOCAL AUTHORITY IN ACCORDANCE WITH THIS SECTION AND 633 | | | FLORIDA STATUTE. | | | | | | 3) NOTE ISSUED PERMIT NUMBER 08060710 WILL ALSO NEED TO | | | MEET THE REQUIREMENTS FOR THRESHOLD BUILDINGS LISTED IN | | | COMMENT # 2A-2C. FL S. S. 553.71(7) . | | | | | | 4) LIFE SAFETY PLAN A120.1 IN THE PLAN NOTES AND IN THE | | | REQUIRED EGRESS WIDTHS ( 0.3 STAIRS AND 0.2 HORIZONTAL | | | AREAS) DOES NOT INDICATE THAT SMOKE CONTROLLED SEATING | | | HAS BEEN ACHIEVED AND THE CALCULATIONS ARE BASED ON | | | SMOKE CONTROLLED SEATING SEE 1024.6.1. PLEASE PROVIDE | | | EITHER COMPLIANCE WITH ALL THE REQUIREMENTS OF 1024.6.2 | | | OR INDICATE THE FACTORS IN 1024.6.1 FOR RAMPS AND | | | STAIRS. | | | NOTE A300.1 THE HIGHEST RAISED FLOOR SECTION APPEARS TO | | | ONLY BE 14'-0" TO THE CORRUGATED ROOF DECK NOT MEETING | | | THE REQUIREMENT OF 1024.6..2.2. | | | | | | 5) LIFE SAFETY PLAN A120.1 & A130.2 THE MAIN ENTRY | | | DOOR# 8 INTO THE SHOW ROOM SWING IN THE WRONG | | | DIRECTION, PLEASE SEE 1024.2 & 1008.1.2. | | | 1024.2 EVERY ASSEMBLY OCCUPANCY SHALL BE PROVIDED WITH | | | A MAIN ENTRANCE/EXIT. THE MINIMUM AGGREGATE WIDTH OF | | | THE MAIN ENTRANCE FOR GROUP A OCCUPANCIES SHALL BE | | | SUFFICIENT TO ACCOMMODATE 50 PERCENT OF THE OCCUPANT | | | LOAD AND SHALL BE AT THE LEVEL OF EXIT DISCHARGE OR | | | SHALL CONNECT TO A STAIRWAY OR RAMP LEADING TO A | | | STREET. EACH LEVEL OF A GROUP A OCCUPANCY SHALL HAVE | | | ACCESS TO A MAIN EXIT AND SUCH ACCESS SHALL HAVE | | | SUFFICIENT CAPACITY TO ACCOMMODATE 50 PERCENT OF THE | | | OCCUPANT LOAD OF SUCH LEVELS. WHERE THE MAIN EXIT FROM | | | AN ASSEMBLY OCCUPANCY IS THROUGH A LOBBY OR FOYER, THE | | | AGGREGATE CAPACITY OF ALL EXITS FROM THE LOBBY OR FOYER | | | SHALL BE PERMITTED TO PROVIDE THE REQUIRED CAPACITY OF | | | THE MAIN EXIT REGARDLESS OF WHETHER ALL SUCH EXITS | | | SERVE AS ENTRANCES TO THE BUILDING. | | | | | | 1008.1.2 EGRESS DOORS SHALL BE SIDE SWINGING. DOORS | | | SHALL BE SWING IN THE DIRECTION OF EGRESS TRAVEL WHERE | | | SERVING AN OCCUPANT LOAD OF 50 OR MORE PERSONS OR A | | | GROUP H OCCUPANCY. | | | | | | 6) WHILE THE FRONT ENTRY DOORS 1,2 & 3 WILL TAKE 50% OF | | | THE OCCUPANT LOAD THE OTHER 50% OF THE OCCUPANT LOAD | | | WILL NEED TO BE TAKEN THROUGH THE OTHER DESIGNATED | | | EXITS, NO OF THE UNKNOWNS IS AT THE EXIT DOOR# 4 THERE | | | IS A COVERED PATIO AREA BUT IS NOT CLEAR AS TO WHAT THE | | | DOUBLE HASHED LINE INDICATES IS THIS A FENCED IN AREA | | | OR IS THIS OPEN FOR THE OCCUPANTS CAN DISPERSE ONCE | | | THEY ARE THROUGH DOOR # 4. | | | IF THIS IS A FENCED IN AREA THEN BOTH DOORS 4& 5 OR | | | 12'-0" OF DOOR OPENING ARE EXITING A 5'-0" AREA, PLEASE | | | CLARIFY THIS AREA. 106.1.2 ADDITIONAL INFORMATION | | | REQUIRED. 1004.5 EGRESS CONVERGENCE. | | | | | | 7) LS A120.1 & A130.2 & A130.3 EXIT HALLWAY | | | CONVERGENCE, THE EXIT CORRIDOR THAT BACKS UP TO THE | | | SHOW ROOM IS 5'-5 1/2" WIDE AND OPENS UP TO 10'-4 PLUS | | | STAIRS FROM THE UPPER SHOWROOM SEATING AREA. THE | | | CAPACITY OF THE HALLWAY IS 620 OCCUPANTS BUT DROPS TO | | | 170 OCCUPANTS AT DOOR # 5. DOOR # 6 AGAIN SWINGS THE | | | WRONG WAY TO BE CONSIDERED AN EGRESS DOOR,1008.1.2. | | | EVEN WITH BOTH DOORS SWINGING IN THE DIRECTION OF | | | TRAVEL YOU WOULD ONLY BE ALLOWED 340 OCCUPANTS THROUGH | | | CREATING A CONVERGENCE ( BOTTLE NECKING EFFECT). | | | 1004.5. | | | | | | 8) LS A120.1 FROM DOORWAY# 5 THROUGH THE CORRIDOR THAT | | | LEADS TO THE LOBBY OR VESTIBULE AREA DOES NOT HAVE | | | EXIT/ EMERGENCY LIGHT WITH BATTERY BACK UP. | | | | | | 9) LS A120 VESTIBULE IS CURRENTLY SET UP AS A WAITING | | | AREA FOR THE NEXT SHOW AND NO EXIT PATH IS PROVIDED FOR | | | THE EXITING PATTRENS. CURRENTLY THIS AREA WILL HOLD | | | OVER 100 OCCUPANTS REQUIRING TWO EXITS AND OVER 1/3RD | | | THE DISTANCE APART. SEE TABLE 1014.1. PLEASE REVISE | | | SHOWING THE DOORS FROM THE SHOW ROOM REVERSED AS AN | | | EXIT (COMMENT# 5) . INDICATE THE EGRESS PATH FROM THE | | | SHOW ROOM AND HOW | | | CROWD CONTROL WILL BE ESTABLISHED FOR THOUGHS EXITING | | | AND FOR THE PATTRENS WAITNG FOR THE NEXT SHOW. | | | | | | 10) SHEET A500.1 DOOR SCHEDULE EGRESS DOORS THAT ARE | | | MISSING PUSH BAR PANIC DEVICE HARDWARE, DOOR 8 WHEN | | | REVERSE, DOOR 6 WHEN REVERSED, DOOR 5,17, 23 & 26. | | | 1008.1.9 | | | ASSEMBLY OCCUPANCY WHEN LOADS OF 100 OR MORE | | | OCCUPANTS. | | | | | | 11) SHEET A 130.2 IN THE UPPER RIGHT SECTION OF THE | | | PLAN AND LOWER RIGHT SECTION OF THE PLAN THERE IS A SET | | | OF STAIRS WHERE THE HANDRAIL DOES NOT FOLLOW THE DECENT | | | PAST THE LAST RISER BUT MAKES A TURN | | | IMMEDIATELY, PLANS CALL FOR A DETAIL 5 / A400.3 THE | | | DETAIL IS BLANK. 11-4.9.4(2) AT THE BOTTOM, THE | | | HANDRAIL SHALL CONTINUE TO SLOPE FOR A DISTANCE OF THE | | | WIDTH OF ONE TREAD FROM THE BOTTOM RISER; THE REMAINDER | | | OF THE EXTENSION SHALL BE HORIZONTAL. THE PLANS | | | INDICATE THE LAST RISER IN LINE WITH THE WALL NOT | | | ALLOWING THE NOT ALLOWING THE SLOPE TO CONTINUE IN A | | | STRAIGHT LINE. | | | | | | 12) LS A120.1 THE RAMP AT THE TOP OF THE SHEET FAILS TO | | | HAVE 6'-0" CLEARENCE AT THE BOTTOM LANDING. | | | 11-4.8.4(2). | | | | | | 13) SHEET A130.2 DETAIL INDICATES 3STAIR DETAILS 4, 5&6 | | | A400.3 PLEASE CORRECT, 106.1.2 ADDITIONAL INFORMATION | | | REQUIRED, WRONG DETAILS. | | | | | | 14) SHEET A 130.3 OFFICE BOTTOM OF RAMP DOES NOT HAVE A | | | 6'-0" CLEAR BOTTOM RAMP. SEE 11-4.8.4(2). | | | | | | 15) SHEET A 130.3 TICKET OFFICE AT DOOR # 4 THE FIRE | | | EXTINGUISHER IS HIDDEN BEHIND THE DOOR WHEN OPENED. NO | | | CODE SECTION JUST A BAD LOCATION IF NOT VISIBLE. | | | | | | 16) LS A120 PLAN FAILS TO INDICATE COMPLIANCE WITH | | | PLACEMENT OF WHEELCHAIR LOCATIONS. 11-4.33.3. | | | | | | 17) LS A120 INDICATE COMPLIANCE WITH 11-4.33.6 | | | PLACEMENT OF LISTENING SYSTEMS. | | | | | | 18) LS A120 SHOW COMPLIANCE WITH 11-4.32.1-2. | | | | | | 19) A140.5 PLEASE PROVIDE SQ FT OF ROOM AND OF THE | | | RAISED PLATFORM AREA, 410.4. | | | | | | 20) A140.1 FLOOR FINISHES PLEASE PROVIDE CARPET | | | DOCUMENTATION WITH COMPLIANCE OF SECTION 804.5.1 , | | | CLASS II FOR THE ASSEMBLY OCCUPANCY. | | | | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
8 |
Status |
P |
Date |
2009-04-23 |
|
|
Cont ID |
|
| Sent By |
dwise |
Date |
2009-04-23 |
Time |
20:59 |
Rev Time |
0.00 |
| Received By |
dwise |
Date |
2009-04-23 |
Time |
20:59 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
F |
Date |
2009-03-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-03-29 |
Time |
09:57 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-03-29 |
Time |
08:37 |
Sent To |
PC |
|
| Notes |
| 2009-03-29 09:57:22 | ** DENIED REVIEW ** | | | | | | *** DENIED REVISIONS*** | | | | | | 1) NOTE: AS GIVEN ON ORIGINAL PROVISO AND IN PREVIOUS | | | NOTES, PLEASE REVISE PLANS TO CONFORM TO THE MINIMUM | | | CODES FOR LIGHTING CONTROLS IN FBC 13-415.1.ABC.1.1, | | | .1.2 AND .1.3. EXAMPLES WERE GIVEN ON PREVIOUS REVIEWS | | | HOWEVER PLANS STILL DO NOT SHOW ITEMS NEEDED. | | | | | | A) IN THE PREVIOUS REVIEW COMMENTS WERE GIVEN WITH | | | RESPECT TO THE BATHROOMS. THESE NOW SHOW *SINGLE POLE* | | | SWITCHES AS THE SEPARATE SPACE CONTROL AND OVER RIDES | | | TO THE LIGHTING CONTROL PANEL WHICH THESE LIGHTS ARE | | | CIRCUITED. | | | THE FIRST ITEM IS THAT ALL THE LIGHTING SHALL BE TURNED | | | OFF ON THIS BUILDING AUTOMATICALLY. ALL SEPARATE SPACES | | | SHALL HAVE CONTROLS EITHER OF THE FOLLOWING: A DEVICE | | | WHICH OVER RIDES THE SCHEDULED SYSTEM OR AUTOMATED | | | SINGLE CONTROLS FOR SUCH SPACE. ( AN EXAMPLE WOULD BE | | | OCCUPANCY SENSORS). IN EITHER CASE THESE DEVICES MUST | | | BE AUTOMATED. | | | SEE SECTIONS ABOVE. | | | | | | B) ANOTHER AREA IS WHEN ENTERING THROUGH THE FRONT DOOR | | | TO SEPARATE BAR SEATING AREA THERE IS NO OVER RIDE | | | CONTROLS OR A OCCUPANCY SENSOR WHICH RIDES THE TIME OF | | | DAY SCHEDULING. | | | SEE SECTIONS ABOVE. | | | | | | C) LIGHTING CIRCUITS/RELAY NUMBERS ON RPA OR ANY OTHER | | | PANEL HAVE NOT ALL BEEN UPDATED. WHERE IS E-3, 5 ETC | | | THE NOTES MENTIONS TO DIMMING CONTROL POWER BOOSTER | | | PANEL HOWEVER THE NOTES FOR CONNECTION OF POWER BOOSTER | | | PANEL TO THE PANEL RPA ARE NOT COMPLETE. | | | THERE IS NO INDICATION FOR CIRCUITING IN RPA OF MANY OF | | | THESE CIRCUITS UNDER THE CONTROL OF THE LIGHTING | | | CONTROL PANEL. | | | | | | ** ONCE AGAIN AS REQUESTED ON PROVISO ON 9/24/08, | | | PROVIDE COMPLETE FUNCTIONALITY OF SYSTEM. | | | PLEASE BE SURE TO ALSO SEE FBC 1006.1.2, NFPA-101 | | | 7.8.1.2.2 FOR CONTROLS FOR *MINIMUM* LIFE SAFETY. | | | | | | 2) NOTE: PLEASE SEE PREVIOUS NOTES WITH RESPECT TO | | | UPDATING ALL LIGHTING PERFORMANCE CALCULATIONS PER | | | 13-415.2, 13-415.2.ABC.1.1, .1.2. | | | THE SAME EXAMPLE GIVEN IS RESTROOM LIGHTING. THESE | | | NEEDS TO BE INCLUDED IN CALCULATIONS BASED ON THE FACT | | | NEW FIXTURES ARE SHOWN. IN OTHER BATHROOMS NO | | | INFORMATION ON FIXTURES ARE SHOWN YET THESE ARE FIGURED | | | INTO CALCULATIONS. | | | PLEASE SEE SHEET E2.2 FOR EXAMPLE: THE LARGE RESTROOMS | | | DO NOT INCLUDE ANY FIXTURE INFORMATION. THIS IS THE | | | SAME FOR THE SMALLER LOCATIONS ALSO. | | | | | | 3) NOTE: AS GIVEN ON PREVIOUS REVIEW. PLEASE UPDATE ALL | | | CIRCUITING ON ALL PANELS WITH PLANS. PLEASE SEE E PANEL | | | CIRCUIT #12, NOTED AS BILLIARD ROOM. THIS ROOM NO | | | LONGER EXISTS. | | | 408.4 | | | ** THIS IS ONLY ONE EXAMPLE; THERE ARE OTHERS. ALL | | | CIRCUITS NEED TO BE SPECIFIC TO THE ROOMS AND AREAS IN | | | WHICH THEY FEED. | | | | | | 4) NOTE: AS NOTED ON PREVIOUS REVIEW: PLEASE UPDATE ALL | | | LOAD CALCULATIONS. ONE EXAMPLE WAS GIVEN THAT NOT ALL | | | LOADS ON PANELS WERE UPDATE AND CARRIED THROUGH. | | | AN EXAMPLE: PANEL *B* PHASE A AND OTHER PHASES ALSO. | | | PLEASE GO OVER ALL LOADS ON ALL PANELS AND UPDATE ALL. | | | THIS IS ONE EXAMPLE GIVEN AS A BENEFIT. | | | 220, 220.12,220.14,220.42,220.44 ETC | | | 215.3, 230.42 | | | | | | 5) NOTE: ONE SET OF PLANS IS BEING RETAINED BY THIS | | | OFFICE. ONLY TWO SETS WILL BE GIVEN BACK. | | | | | | | | | | | | | | | | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
F |
Date |
2009-01-02 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-01-02 |
Time |
18:54 |
Rev Time |
2.00 |
| Received By |
dpalmer |
Date |
2009-01-02 |
Time |
18:54 |
Sent To |
|
|
| Notes |
| 2009-01-02 18:55:06 | ** DENIED REVIEW OF REVISIONS ** | | | | | | 1) NOTE: PLEASE LABEL ALL REVISIONS ON PLANS WITH | | | CLOUDS WITH REVISION NUMBER IDENTIFICATION AS NOTED IN | | | TITLE BLOCKS. THERE HAVE BEEN TWO SETS OF REVISIONS | | | MADE HOWEVER UNTIL NOW NO REVISIONS WERE SUBMITTED FOR | | | REVIEW. THE NUMERICAL DESIGNATION IS ON PLANS HOWEVER | | | THE REVISED ITEMS HAVE NOT BE IDENTIFIED. | | | FBC 106.5, 106.1.1, NEC 2005, FBC 2005 FOR CLARITY, | | | COORDINATION AND ADDITIONAL INFORMATION NEEDED. | | | | | | 2) NOTE: PLEASE SEE PROVISO ISSUED IN SEPTEMBER OF | | | 2008. NO REVISED ELECTRICAL PLANS HAVE COME INTO THIS | | | OFFICE GIVING THE FUNCTIONALITY OF THE TENANT SPACE | | | LIGHTING CONTROL SYSTEM IN ORDER TO VERIFY NOT ONLY | | | LIGHTING CONTROL COMPLIANCE PER FBC CHAPTER 13 BUT ALSO | | | THE LIGHTING FOR EGRESS UNDER NORMAL, EMERGENCY AND | | | SHOW CONDITIONS. | | | THIS WAS A REQUEST OF DESIGNER SO THE SYSTEM COULD BE | | | WORKED OUT. | | | THE PROJECT IS NOW REQUESTING A TCO AND ONLY SOME ITEMS | | | HAVE BEEN REVISED ON PLANS. SOME ITEMS ON PLANS ARE NOT | | | COMPLETE AND THE COMMENTS FROM PREVIOUS PROVISO IS | | | STILL IN NEED OF ADDRESSING. | | | FBC 13-415.1.ABC.1.1, .1.2, .1.3. LS 101 7.8, 7.9, FBC | | | 1006.1 | | | | | | A) PLEASE SEE THERE ARE LIGHTING FIXTURES ON PLANS | | | WHICH HAVE BEEN REVISED WHICH NOW DO NOT INDICATE ANY | | | CIRCUITING OR CONTROLS. SEE RECESSED FIXTURES AND | | | SCONCES AT ENTRANCE INTO CLUB AREA AS ONE EXAMPLE. | | | | | | B) PLEASE SEE CIRCUITING ON THE LIGHTING CONTROL PANEL | | | SHALL BE UPDATED FOR ALL ALONG WITH PANEL SCHEDULES. | | | ONE EXAMPLE OF COORDINATION IS THE BILLIARD ROOM WHICH | | | IS STILL SHOWN AS CIRCUIT #12 ON THE RPA PANEL YET | | | THERE IS NO LONGER A BILLIARD ROOM. | | | THIS IS ONLY ONE. | | | | | | C) NOTE: PLEASE SEE AREAS SUCH AS THE LARGE MULTI-GANG | | | BATHS WHICH DO NOT COMPLY WITH SEPARATE SPACE CONTROL | | | EVEN THOUGH THEY ARE WIRED TO THE LIGHTING CONTROL | | | PANEL. PLEASE SEE 13-415.1.ABC.1.2. THIS MUST HAVE | | | SEPARATE CONTROL. | | | PLEASE SEE OTHER SMALLER BATHS WHICH INDICATE MOTION | | | SENSORS HOWEVER VERIFY THESE AS DUAL TECHNOLOGY IN | | | ORDER TO MEET THE LIFE SAFETY CODE FOR OCCUPANTS IN ANY | | | STALL AREAS. | | | | | | D) PLEASE REVISE ALL PHOTO-METRICS FOR NORMAL, AND SHOW | | | TIMES. AT THE REQUEST OF THE DESIGNER THIS WAS GOING TO | | | BE MEASURE AND SHOWN ONCE INSTALLED. IT WAS KNOWN TO | | | BOTH THE ARCHITECT AND KAMM CONSULTING THAT IF THE | | | STAIR LEVEL LIGHTING AND OTHER AREAS DID NOT MEET THE | | | MINIMUM IN THE LIFE SAFETY CODE THAT FIXTURES MAY NEED | | | TO BE ADDED. THIS NEEDS TO BE CONFIRMED AND SHOWN. | | | RECORD PLANS NEED TO SHOW THIS. A FIELD INSPECTION MAY | | | ALSO BE NEEDED. | | | | | | ** THE PROVISO WAS GRANTED IN ORDER TO PERMIT THE | | | PROJECT AND TO GET EVERYTHING STARTED. THE PROVISO IS | | | GIVEN TO GIVE THE CONTRACTOR AND THE DESIGN TEAM THE | | | OPPORTUNITY TO OBTAIN INFORMATION ETC AND REVISE PLANS. | | | IN THE MEETING HELD BEFORE PERMIT ISSUANCE THIS | | | REVIEWER SPECIFICALLY MENTION REVISED PLANS NEEDED TO | | | BE SUBMITTED IN PLENTY OF TIME WITH ALL INFORMATION | | | BEFORE FINAL INSPECTIONS WERE BEING SCHEDULED. | | | SUBMITTING THE PLANS THE WEEK BEFORE NEEDED FINALS IS | | | NOT ENOUGH TIME TO DO REVIEWS, ADDRESS ANY POSSIBLE | | | COMMENTS AND FOR PLANS TO BE ON THE SITE FOR | | | INSPECTIONS. | | | | | | | | | 3) NOTE: PREVIOUS PLANS CLEARLY INDICATE THE EXISTING | | | TRANSFORMER TEA AS GROUND MOUNTED, NOW THE POWER PLANS | | | INDICATES THIS AS ABOVE. TRANSFORMERS OVER 50KVA ARE | | | NOT PERMITTED ABOVE THE CEILING. PLEASE EXPLAIN WHAT IS | | | MEANT BY *ABOVE* AS STATED ON PLANS. | | | PLEASE SEE 450.13 AS THE LOCATION NEEDS TO BE VERIFIED | | | MEETING CODE COMPLIANCE. | | | | | | 4) NOTE: LOADS ON PANELS AND EQUIPMENT ALONG WITH | | | CIRCUITING HAS BEEN REVISED HOWEVER NOT ALL LOADS ETC | | | HAVE BEEN CARRIED THROUGH. ONE EXAMPLE IS PANEL K1 | | | WHICH HAS A SUBSTANTIALLY INCREASED LOAD WHICH AFFECTS | | | H1A YET THE LOAD ON THE MAIN SERVICE LOAD CALCULATIONS | | | HAS NOT BEEN REVISED. THE PLANS IN FACT SHOW THE SAME | | | LOADS AS NOTED ON ORIGINAL PERMITTED PLANS. | | | | | | 5) NOTE: THE LIGHTING PERFORMANCE CALCULATIONS NEED TO | | | BE UPDATED WITH ALL LIGHTING IF ALLOWANCES FOR ALL | | | LIGHTING IS GOING TO BE USED. AN EXAMPLE OF THIS IS THE | | | ALLOWANCE BEING FIGURED FOR RESTROOMS YET NO FIXTURES | | | WITH ANY INFORMATION IS ON PLANS. MAY NOT USE THE SQ FT | | | WITHOUT INCLUDING ALL LIGHTS. AS THESE SUPPOSEDLY ARE | | | EXISTING TO REMAIN PLEASE REMOVE. IF THESE ARE NEW, | | | THEN REVISED ALL INFORMATION FOR FIXTURES ETC | | | 13-415.2.ABC.1.1,.1.2. | | | ALL SPECIFIC FIXTURES NEED TO BE LISTED WITH | | | MANUFACTURE AND MODEL NUMBER ETC. THE VERIFICATION OF | | | LIGHTING COMPLIANCE CAN NOT BE CONFIRMED. | | | PLEASE KEEP IN MIND ALL WATTAGE USED FOR CALCULATIONS | | | SHALL BE BASED ON THE RATING OF FIXTURE NOT THE FIXTURE | | | BULB RATING. | | | ALL FIXTURES SHALL CONTAIN A LISTING FROM A NRTL.110.3 | | | | | | | | | | | | | | | | | | ** IMPORTANT ** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED | | | INTO TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2008-12-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-12-01 |
Time |
13:32 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-12-01 |
Time |
13:32 |
Sent To |
PC |
|
| Notes |
| 2008-12-01 13:32:52 | | | | ** FAILED REVISION** | | | | | | | | | 1) NOTE: PLEASE SUBMIT COORDINATING PLANS FOR REFLECTED | | | CEILING WITH RESPECT TO LIGHTING AND AREAS. | | | FOR EXAMPLE: SHEETS A180.1 AND OTHERS IN ARCHITECTURAL | | | SET WHICH WERE JUST RECENTLY REVISED DO NOT CONTAIN | | | MANY OF THE SAME LIGHTING FIXTURES WHICH ARE ON THE | | | ELECTRICAL PLANS. | | | PLEASE SEE AREAS SUCH AS THE * SEATING AREA* OUTSIDE | | | THE RESTROOMS WHICH ON ELECTRICAL PLANS IS SHOWN AS A * | | | PRIVATE BILLIARD ROOM*. | | | | | | 2) NOTE: PLEASE SUBMIT REVISED LIGHTING PERFORMANCE | | | CALCULATIONS. PLEASE EXPLAIN HOW THE LIGHTING DESIGN | | | WATTAGE HAS GONE DOWN FROM PERMITTED PLANS WHEN | | | FIXTURES SUCH AS THE *E* FIXTURE HAS ACTUALLY INCREASED | | | IN THE WATTAGE. IN FACT FIXTURE *E* HAS MORE THAN | | | DOUBLED IN THE WATTAGE ON THE FIXTURE LEGEND. | | | PLEASE BE SURE TO COORDINATE ALL. | | | 13-415.2,13-415.2.ABC.1.1,1.2. | | | | | | 3) NOTE: PLEASE SEE * PROVISO* FROM PERMIT ISSUANCE. | | | PLEASE SUBMIT INFORMATION AND DOCUMENTATION FOR | | | FUNCTIONALITY OF LIGHTING CONTROL SYSTEM AND SEQUENCE | | | OF OPERATION. | | | 13-415.1.ABC.1.1,.1.2 AND.1.3. | | | | | | | | | **IMPORTANT** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED | | | INTO TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-11-24 |
Time |
14:39 |
Sent To |
|
|
| Notes |
| 2008-11-24 14:40:42 | ELECTRICAL REVISIONS SUBMITTED UNDER STRUCTURAL PERMIT | | | ALONG WITH MECHANICAL REVISIONS HAVE BEEN ROUTED TO | | | ADRIANNA MCKENZIE. PLANS SUBMITTED UNDER INORRECT | | | PERMIT. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2008-09-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-09-24 |
Time |
16:58 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-09-24 |
Time |
16:58 |
Sent To |
|
|
| Notes |
| 2008-09-24 16:58:12 | | | | ** PROVISO/REDLINED ** | | | | | | 1) NOTE: SYSTEM FUNCTIONS FOR LIGHTING CONTROLS AND | | | EGRESS LIGHTING SHALL BE VERIFIED FOR MEETING LIFE | | | SAFETY CODE 7.8.1.2.2, 7.8.1.3 7.9.1 AND FBC | | | 1006.1.2.THE SYSTEM OPERATION FOR LIFE SAFETY EGRESS | | | UNDER NORMAL AND EMERGENCY CONDITIONS WILL BE FIELD | | | INSPECTED AND FINAL PLANS SHALL PROVIDE A DETAILED | | | SEQUENCE OF OPERATION. | | | THIS OFFICE MAY FIELD INSPECT SYSTEM FOR FUNCTIONALITY | | | MEETING THE FBC CHAPTER 13, 11, 10 AND LS 101 7.8, 7.9. | | | | | | 2) NOTE: AS OF REVIEW SHEETS FA.01 AND 2.1 ARE MISSING | | | FROM ONE SET. NEED TO BRING IN BEFORE FIRE REVIEW AND | | | PLACE IN SETS. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE DO NOT HESITATE TO | | | CONTACT THIS OFFICE. | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANOR PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2008-09-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-09-12 |
Time |
15:24 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-09-12 |
Time |
15:24 |
Sent To |
|
|
| Notes |
| 2008-09-12 15:25:10 | | | | | | | | | | | | | ** DENIED 2ND REVIEW ** | | | | | | | | | | | | | | | 1) NOTE: PLEASE SEE THE LIGHTING CONTROLS DO NOT MEET | | | SECTIONS OF THE CODES GIVEN ON PREVIOUS REVIEW. SOME | | | SPECIFIC EXAMPLES WILL BE GIVEN BELOW. | | | PLEASE SEE 13-415.1.ABC.1.1, .1.2, .1.3. | | | | | | FOR EXAMPLE: PLANS INDICATE LIGHTING CONTROL CIRCUIT | | | E-38 WHICH BY NOTES TAKE THIS BACK TO THE LIGHTING | | | CONTROL PANEL *RPA*. BASED ON THE ONLY TWO SWITCH BANKS | | | NOTED, THIS IS NOT PART OF EITHER SWITCH BANK. | | | | | | FOR EXAMPLE: PLEASE SEE CIRCUITS E-30 AND E20 WHICH ARE | | | SHOWN TO EXIT/EGRESS HALLWAYS. WHERE ARE THE SEPARATE | | | CONTROLS REQUIRED? | | | ** PLEASE BE SURE TO SEE COMMENTS BELOW WITH RESPECT TO | | | LIFE SAFETY NFPA-101. | | | | | | FOR EXAMPLE: PLEASE SHOW WHERE AND HOW AREAS AS NOTED | | | ABOVE FOR SEPARATE CONTROLS MEET SECTIONS. THE OCCUPANT | | | IS REQUIRED TO SEE *ALL* LIGHTING WHICH IS BEING | | | CONTROLLED OR MEET THE EXCEPTIONS IN THE CODE. THE | | | PLANS DO NOT SHOW THIS. | | | | | | | | | ** THIS IS ONLY A COUPLE OF EXAMPLES. THIS IS GIVEN AS | | | A BENEFIT ONLY AND IS NOT ALL ITEMS WHICH NEED TO BE | | | ADDRESSED WITH RESPECT LIGHTING CONTROLS. | | | | | | 2) NOTE: PLEASE SEE 13-415.2, 13-415.2.ABC.2.1, | | | 13-415.2.ABC .2.2 FOR LIGHTING PERFORMANCE | | | CALCULATIONS. PLEASE BE SURE TO SEE THE CODE SECTIONS | | | AS GIVEN AND PLEASE COORDINATE ALL LIGHTING ON THE | | | FIXTURE LEGEND AND THE CALCULATIONS. | | | | | | ONE EXAMPLE: PLEASE SEE FIXTURE *J* WHICH INDICATES | | | THIS ON THE LIGHTING PERFORMANCE CALCULATIONS AS A | | | 35WATT FIXTURE HOWEVER SEE SHEET E0.1 WHICH INDICATES | | | THIS SAME FIXTURE AS 150WATT. | | | | | | ** THIS WAS ONLY ONE EXAMPLE: PLEASE COORDINATE *ALL* | | | FIXTURES, THE NUMBER OF FIXTURES, THE TYPES OF | | | FIXTURES, THE COUNT ETC. | | | | | | 3) NOTE: PLEASE SEE FBC 1006.1.2 AND NFPA-101 | | | 7.8.1.2.2. BASED ON PLANS AND NOTES ABOVE THE LIGHTING | | | IN EGRESS/EXIT HALLWAYS ARE BEING SHOWN ON THE LIGHTING | | | CONTROL PANEL *RPA* WHICH IS OK, HOWEVER IF THIS | | | LIGHTING CONTROL PANEL OR THE OVER RIDES SHOWN TURN OFF | | | THE LIGHTING AT ANY POINT, THESE AREAS ARE LEFT IN | | | TOTAL DARKNESS WITH NO OVER RIDE DEVICES SUCH AS FAIL | | | SAFE OCCUPANCY SENSORS ETC. | | | THIS IS A MAJOR LIFE SAFETY ISSUE AND BASED ON THE | | | CODE(S) THE METHOD OF CONTROLS IN THESE AREAS AND ANY | | | EGRESS AREA NEEDS TO BE RE-=CONSIDERED IN DESIGN. | | | PLEASE BE SURE TO SEE THE NEXT COMMENT. | | | | | | 4) NOTE: PLEASE SEE TYPE *M* FOR EXAMPLE: THE FIXTURE | | | LEGEND INDICATES THIS FIXTURE IS TO BE SELECTED HOWEVER | | | BASED ON THIS FIXTURE BEING LOCATED IN MANY EGRESS | | | PATHS OR CORRIDORS. | | | AS THIS FIXTURE SIMPLY NOTES TO SEE ARCHITECTURAL FOR | | | HEIGHTS AND THE SPECIFIC FIXTURE IS NOT CALLED OUT | | | PLEASE KNOW A SPECIFIC FIXTURE IS REQUIRED TO BE SHOWN | | | MEETING CODE COMPLIANCE ALONG WITH HEIGHTS/LOCATIONS | | | ETC TO MEET FBC 11.4.4.1 | | | | | | 11-4.4.1 GENERAL. | | | OBJECTS PROJECTING FROM WALLS (FOR EXAMPLE, TELEPHONES) | | | WITH THEIR LEADING EDGES BETWEEN 27 INCHES AND 80 | | | INCHES (685 MM AND 2030 MM) ABOVE THE FINISHED FLOOR | | | SHALL PROTRUDE NO MORE THAN 4 INCHES (102 MM) INTO | | | WALKS, HALLS, CORRIDORS, PASSAGEWAYS, OR AISLES [SEE | | | FIGURE 8(A)]. OBJECTS MOUNTED WITH THEIR LEADING EDGES | | | AT OR BELOW 27 INCHES (685 MM) ABOVE THE FINISHED FLOOR | | | MAY PROTRUDE ANY AMOUNT [SEE FIGURE 8(A) AND FIGURE | | | 8(B)]. FREE-STANDING OBJECTS MOUNTED ON POSTS OR PYLONS | | | MAY OVERHANG 12 IN (305 MM) MAXIMUM FROM 27 INCHES TO | | | 80 INCHES (685 MM TO 2030 MM) ABOVE THE GROUND OR | | | FINISHED FLOOR [SEE FIGURE 8(C) AND FIGURE 8(D)]. | | | PROTRUDING OBJECTS SHALL NOT REDUCE THE CLEAR WIDTH OF | | | AN ACCESSIBLE ROUTE OR MANEUVERING SPACE [SEE FIGURE | | | 8(E)]. | | | 11-4.4.2 HEADROOM. WALKS, HALLS, CORRIDORS, | | | PASSAGEWAYS, AISLES, OR OTHER CIRCULATION SPACES SHALL | | | HAVE 80 INCHES (2030 MM) MINIMUM CLEAR HEAD ROOM [SEE | | | FIGURE 8(A)]. IF VERTICAL CLEARANCE OF AN AREA | | | ADJOINING AN ACCESSIBLE ROUTE IS REDUCED TO LESS THAN | | | 80 INCHES (2032 MM) (NOMINAL DIMENSION), A BARRIER TO | | | WARN BLIND OR VISUALLY-IMPAIRED PERSONS SHALL BE | | | PROVIDED [SEE FIGURE 8(C-1)]. | | | | | | ** BE SURE TO SEE OTHER FIXTURES IN OTHER LOCATIONS. | | | THERE ARE THREE HALLWAYS (AS NOTED ON PLANS) WHICH TYPE | | | *M* FIXTURES ARE OF CONCERN. | | | | | | 5) NOTE: PLEASE SEE PREVIOUS NOTES WITH RESPECT TO | | | EGRESS STAIRS PER LS 101 7.8.1.3. THE NEW PHOTO-METRICS | | | SUBMITTED DO NOT INDICATE THE 10FT CANDLE UNDER NORMAL | | | LEVELS. | | | *** ALL STAIRS INCLUDING AREAS WHERE PERFORMANCES ARE | | | LOCATED. ** DURING TIMES OF PERFORMANCES LIGHTING | | | LEVELS ARE PERMITTED TO MEET EXCEPTIONS HOWEVER ALL | | | OTHER NORMAL TIMES OF OCCUPANCY MUST MEET THE *MINIMUM* | | | FOR THE LIFE SAFETY CODE. | | | DUE TO THE AMOUNT OF THE SCOPE OF WORK SOME BATHROOM | | | AREAS WILL BE REQUIRED TO ADD BATTERY BACK UP LIGHT | | | FIXTURES OF SOME KIND. FOR EXAMPLE: PLEASE SEE RESTROOM | | | AND CORRIDOR IN NE CORNER TENANT SPACE. | | | | | | 6) NOTE: PLEASE COORDINATE PANELS AND RISER: | | | | | | FOR EXAMPLE: PANEL *H1* SHOWS A SUB-FEED TO A | | | TRANSFORMER *T1* YET THERE IS NO TRANSFORMER *T1* ON | | | RISER OR PLANS. | | | 240.21,310.16,240.4, 450.3 ETC | | | FBC 106.1.1, 106.3.5.1.2 FOR CLARITY AND ADDITIONAL | | | INFORMATION. | | | | | | 7) NOTE: PLEASE EXPLAIN HOW THE THREE POLE BREAKERS ON | | | PANELS K1 AND H1 TAKE SPACE FOR 6-POLES EACH. | | | WHAT TYPE OF BREAKER DOES THIS? PLEASE SUPPLY CUT SHEET | | | FOR THIS TYPE OF BREAKER OR IS THIS A MISPRINT OF SOME | | | SORT? NE C110.3,90.7 | | | | | | 8) NOTE: PLEASE SHOW COMPLETE LOAD CALCULATIONS ON | | | EXISTING SERVICE IN WHICH NEW LOADS ARE BEING ADDED. | | | PLEASE EXPLAIN HOW THE LOAD FOR WHAT IS BEING ASSUMED | | | AS TRANSFORMER TEA IS NOT THE SAME ON PANEL *H1*. | | | 220.87 | | | FBC 106.1.1, 106.3.5.1.2 FOR ADDITIONAL INFORMATION AND | | | CLARITY. | | | | | | 9) NOTE: PLEASE SEE FS 553.80(2)(B) WITH RESPECT TO | | | REPEAT COMMENTS FOR CODE COMPLIANCE. THIS IS ONLY A | | | NOTICE AT THIS TIME. ONE SET OF ELECTRICAL PLANS ARE | | | BEING RETAINED AND WILL BE PLACED WITH PREVIOUS PLANS | | | RETAINED. | | | | | | | | | | | | **IMPORTANT** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | | TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANOR PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2008-07-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-07-18 |
Time |
17:14 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-07-18 |
Time |
17:14 |
Sent To |
|
|
| Notes |
| 2008-07-18 17:14:45 | ** DENIED REVIEW ** | | | | | | 1) NOTE: **** PLEASE READ **** | | | IT IS IMPORTANT TO UNDERSTAND THAT THE PLANS SUBMITTED | | | ARE NOT COMPLETE. THERE ARE SEVERAL ITEMS MISSING FROM | | | MINIMUM CODE COMPLIANCE DESIGN. AS MANY OF THESE ITEMS | | | ARE NOT SHOWN A COMPLETE REVIEW FOR MINIMUM CODE | | | COMPLIANCE CAN NOT BE DONE AT THIS TIME. PLEASE BE SURE | | | TO SEE ALL COMMENTS BELOW AND UNDERSTAND THERE MAY VERY | | | WELL BE NEW COMMENTS ON THE FOLLOWING REVIEW. | | | ** CALLED KAMM CONSULTING AND SPOKE TO ART KAMM WITH | | | RESPECT TO PLANS. MR. KAMM MADE COMMENT THAT INCORRECT | | | PLANS WERE SIGNED, SEALED AND SUBMITTED. | | | ONE COPY OF ELECTRICAL PLANS WERE RETAINED. | | | | | | 2) NOTE: PLEASE SUBMIT COMPLETE PLANS WITH ALL | | | CIRCUITING FOR ALL LIGHTING. | | | NEC 408, 240.4, 310.16 ETC | | | FBC 106.1.1, 106.1.2, 106.3.5.1.2 | | | | | | 3) NOTE: PLEASE SEE 700.12F FOR CIRCUITING OF EMERGENCY | | | LIGHTS AND EXIT LIGHTS. | | | | | | 4) NOTE: PLEASE SUBMIT PLANS SHOWING COMPLIANCE WITH | | | FBC 13-415.1.ABC.1.1, .1.2, .1.3 AND .1.4. MOST | | | REQUIRED LIGHTING CONTROLS ARE MISSING FROM PLANS. | | | | | | 5) NOTE: PLEASE COMPLETE PLANS FOR IDENTIFICATION OF | | | ALL LIGHTING FIXTURES. PLEASE SUBMIT COMPLETE LIGHTING | | | PERFORMANCE CALCULATIONS PER 13-415.2, | | | 13-415.2.ABC.1.1, .1.2. | | | PLEASE SEE THE PARTIAL LIGHTING DENSITIES SHOWN ON | | | E-2.1 ARE NOT CODE COMPLIANT IN ANY WAY. | | | | | | 6) NOTE: PLEASE SEE THE CONDUCTORS ON THE SECONDARY | | | SIDE OF TRANSFORMER TEA TO PANEL K1 SHALL MEET OR | | | EXCEED THE OVER CURRENT PROTECTION IN WHICH THE TAPPED | | | CONDUCTORS TERMINATES. TYPICALLY IT IS PERMITTED TO GO | | | TO THE NEXT SIZE UP HOWEVER NOT ON THE SECONDARY SIDE | | | OF A TRANSFORMER. | | | 240.4,310.16,240.21,240.6 ETC | | | ** THIS IS A LIFE SAFETY AND FIRE HAZARD AND SHALL BE | | | CORRECTED EVEN IF EXISTING. | | | | | | 7) NOTE: PLEASE SEE RISER SHOWS PANELS E AND F YET THE | | | PANEL SCHEDULES WERE NOT SUBMITTED ON SHOWN ON PLANS. | | | 408.4, 215.5, 240.21, 408.36 | | | FBC 106.3.5.1.2, 106.1.1 | | | | | | 8) NOTE: PLEASE SUBMIT PHOTO-METRICS AND LIGHTING | | | LEVELS FOR ALL EGRESS PATHS. PLEASE SEE NFPA-101 2006 | | | 7.8.1.3, 7.9.2.1 | | | AS FIXTURES ARE NOT COMPLETEAND UNCLEAR IT IS NOT | | | KNOWN ALL FIXTURES WHICH MAY PROVIDE THE BACK UP | | | ILLUMINATION. | | | | | | 9) NOTE: PLEASE SEE 450.13 AS THE TRANSFORMER ARE NOTED | | | AS BEING ABOVE THE CEILING WHICH IS NOT PERMITTED. | | | | | | 10) NOTE: PLEASE SEE A NOTE ON PLANS MENTIONS THE | | | REQUIRED GFI PROTECTION HOWEVER PLEASE INDICATE THE | | | PROTECTION BY THE DEVICE OR THE CIRCUIT. PLEASE SEE | | | THAT ALL RECEPTACLES IN KITCHEN AREAS WHETHER OR NOT | | | THE FEED COUNTER SPACES SHALL BE PROTECTED FOR 15/20AMP | | | AND 125V. | | | PLEASE SEE RECEPTACLES WITHIN 6FT OF WET BAR SINKS | | | SHALL ALSO CONTAIN GFI PROTECTION. | | | 210.8B2 | | | | | | 11) NOTE: PLEASE COMPLETE PANEL SCHEDULE TO ALL ROOMS | | | AND AREAS IN WHICH CIRCUITS FEED. THE USE OF *LIGHTING | | | OR RECEPTACLES* IS NOT ACCEPTABLE. 408.4 | | | FBC 106.1.1,106.1.2,106.5 | | | | | | 12) NOTE: PLEASE BE SURE THE LATEST ADOPTED CODES FOR | | | ELECTRICAL, LIFE SAFETY DESIGN IS STATED ON PLANS. 2005 | | | NFPA-70 | | | 2002 NFPA-72 | | | 2003 NFPA-101 | | | | | | 13) NOTE: PLEASE SUBMIT COMPLETED PLANS FOR BASE FIRE | | | ALARM SYSTEM. | | | PLEASE BE SURE TO SEE FBC 11-4.28.1,.2 AND .3 FOR | | | MINIMUM DEVICES FOR ADA COMPLIANCE. | | | | | | 14) NOTE: PLEASE SEE LIFE SAFETY CODE CHAPTER 7 | | | NFPA-101.7.10.8.3.1 ANY DOOR, PASSAGE, OR STAIRWAY THAT | | | IS NEITHER AN EXIT NOR A WAY OF EXIT ACCESS AND THAT IS | | | LOCATED OR ARRANGED SO THAT IT IS LIKELY TO BE MISTAKEN | | | FOR AN EXIT SHALL BE IDENTIFIED BY A SIGN THAT READS AS | | | FOLLOWS: NO EXIT 7 | | | 7.8.10.3.2 THE NO EXIT SIGN SHALL HAVE THE WORD NO IN | | | LETTERS 51 MM (2 IN.) HIGH, WITH A STROKE WIDTH OF 9.5 | | | MM (IN.), AND THE WORD EXIT IN LETTERS 25 MM (1 IN.) | | | HIGH, WITH THE WORD EXIT BELOW THE WORD NO, UNLESS SUCH | | | SIGN IS AN APPROVED EXISTING SIGN. | | | | | | | | | | | | | | | IMPORTANT** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | | TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2009-01-07 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2009-01-07 |
Time |
18:52 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2009-01-07 |
Time |
17:50 |
Sent To |
|
|
| Notes |
| 2009-01-07 18:42:55 | *****REVISION #4, DATED 12/01/2008, APPROVED***** | | | | | | | | | REVIEWED REVISED SHEETS A120.2, A120.4, A130.2, A130.4, | | | A180.1, A180.4, AND A500.1; SHEETS A120.2, A120.4, AND | | | A500.1 WERE FIRE STAMPED, INITIALED, AND DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2008-11-04 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-11-04 |
Time |
12:09 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-11-04 |
Time |
12:09 |
Sent To |
|
|
| Notes |
| 2008-11-04 12:09:33 | REVISION DATED 10/17/08 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2008-09-16 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-09-16 |
Time |
10:04 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-09-16 |
Time |
10:04 |
Sent To |
|
|
| Notes |
| 2008-09-16 10:07:49 | ***PROVISO*** | | | | | | COMMENTS FROM FIRST FIRE REVIEW HAVE BEEN ADDRESSED PER | | | PREVIOUS MEETING. | | | | | | 1) THIS WRITER PROVIDED THE INCORRECT EDITION FOR NFPA | | | 13. THE CORRECT EDITION SHOULD READ 2002. | | | | | | 2) PLEASE SEE BUILDING REVIEW COMMENTS REGARDING | | | THRESHHOLD BUILDING REQUIREMENTS. | | | | | | | | | PLANS WILL BE STAMPED WHEN RETURNED WITH CORRECTIONS. | | | | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | | FIRE PLAN REVIEW | | | FIRE PREVENTION (561) 804-4756 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2008-07-24 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-07-24 |
Time |
13:56 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-07-24 |
Time |
13:56 |
Sent To |
|
|
| Notes |
| 2008-07-24 14:11:15 | ***DENIED*** | | | | | | 1) PLEASE ADD THE FOLLOWING CODE TO APPLICABLE CODE | | | SECTION: | | | A) FIRE SPRINKLER WORK SHALL COMPLY WITH THE | | | REQUIREMENTS OF NFPA 13, 2003. | | | | | | 2) SEPARATE SHOP DRAWINGS AND PERMIT REQUIRED FOR FIRE | | | SPRINKLER REMODEL. ADDITIONALLY, PROVIDE A FIRE | | | SPRINKLER LAYOUT WITH MASTER PERMIT SUBMITTAL. | | | | | | 3) EXISTING BUILDING FIRE PROTECTION SYSTEMS SHALL | | | REMAIN IN SERVICE. CONTACT WPB BUREAU OF FIRE | | | PREVENTION AT (561) 804-4724 SHOULD ANY INTERUPTION OF | | | REQUIRED SYSTEMS OCCUR. | | | | | | 4) JOB SITE TO BE CLEANED OF EXCESS DEBRIS DAILY OR | | | MORE FREQUENTLY TO MAINTAIN SAFE OPERATION. | | | | | | 5) PROVIDE MINIMUM INTERIOR FINISH CLASSIFICATION FOR | | | WALLS AND CEILING THAT IS SPECIFIC TO THIS PROJECT. | | | | | | 6) PROVIDE PRESCRIPTIVE STENGTH REQUIREMENTS FOR | | | HANDRAILS AND GUARDS. | | | | | | 7) KNOX BOX IS REQUIRED FOR AFTER NORMAL BUSINESS HOURS | | | EMERGENCY SERVICE ACCESS. CONTACT WPB BUREAU OF FIRE | | | PREVENTION AT (561) 804-4724 FOR ASSISTANCE. | | | | | | 8) EGRESS DOORS SERVING AN AREA OR ROOM THAT SERVES | | | GREATER THAN (100) OCCUPANTS SHALL BE PROVIDED WITH | | | PANIC OR FIRE EXIT HARDWARE.CLEARLY IDENTIFY APPLICABLE | | | DOORS. RATED DOORS SHALL BE PROVIDED WITH UL LISTED | | | CLOSERS FOR POSITIVE LATCH EFFECT. PLEASE ADD TO DOOR | | | SCHEDULE. | | | | | | 9) OCCUPANT LOAD SIGNS TO BE POSTED PRIOR TO FINAL | | | INSPECTION. | | | | | | 10) RAMPS TO COMPLY WITH NFPA 101, SEC. 7.2.5. | | | | | | 11) DOOR SWINGS IN AREAS OR ROOMS SERVING (50) OR MORE | | | OCCUPANTS SHALL SWING IN THE DIRECTION OF TRAVEL. | | | | | | 12) HOOD SUPPRESSION SYSTEM SHALL BE TIED INTO THE | | | BUILDING FIRE ALARM SYSTEM. NEW HOOD SUPPRESSION | | | SYSTEMS SHALL COMPLY WITH THE REQUIREMENTS OF UL 300 | | | FOR WET CHEMICAL AGENT. SEPARATE SHOP DRAWINGS AND | | | PERMIT REQUIRED FOR NEW OR ALTERED HOOD/SUPPRESSION | | | SYSTEMS. | | | | | | 13) SOFFITS SHALL NOT INTERFERE WITH OR OBSTRUCT FIRE | | | SPRINKLER COVERAGE. | | | | | | 14) SOME SHEETS ILLUSTRATE AN EXIT SIGN LEADING | | | OCCUPANTS FROM THE MAIN EAST EXIT HALLWAY INTO A | | | SEATING AREA WITH OBSTRUCTION OF TABLES AND CHAIRS. | | | PLEASE CORRECT AND CORRELATE ALL SHEETS. | | | | | | 15) ELECTRICAL POWER PLAN (SHEET E-3.1) DOES NOT | | | INDICATE ANY LAY OUT OF FIRE ALARM EQUIPMENT. IN | | | ADDITION, SEPARATE SHOP DRAWINGS AND PERMIT REQUIRED | | | FOR FIRE ALARM REMODEL OR INSTALLATION. | | | | | | 16) HOW WILL THIS PROJECT IMPACT EXISTING MEANS OF | | | EGRESS, MORE SPECIFICALLY EXIT DISCHARGE? | | | | | | 17) THE DOOR SWING FROM THE VESTIBULE IS CONFLICTING ON | | | DIFFERENT SHEETS. PLEASE CORRELATE INFORMATION. | | | | | | 18) CONTACT BUREAU OF FIRE PREVENTION PRIOR TO CUTTING | | | OR WELDING OPERATIONS. WORK SHALL COMPLY WITH NFPA | | | 51B. | | | | | | 19) DUCT SMOKE DETECTORS IN ADDITION TO FAN SHUT DOWN, | | | SHALL INITIATE A GENERAL FIRE ALARM IN ACCORDANCE WITH | | | LOCAL REQUIREMENTS. | | | | | | 20) PLEASE EXPLAIN HOW SMOKE WOULD BE REMOVED OR | | | RELOCATED SHOULD A FIRE EMERGENCY OCCUR. | | | | | | 21) FIRE ALARM SYSTEM TO BE UL CERTIFICATED FOR CENTRAL | | | STATION SERVICE. | | | | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | | FIRE PLAN REVIEW | | | FIRE PREVENTION (561) 804-4756 | | | | | | | | | | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
4 |
Status |
F |
Date |
2009-01-06 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-01-06 |
Time |
17:12 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-01-05 |
Time |
18:56 |
Sent To |
|
|
| Notes |
| 2009-01-06 17:33:01 | REVISION DENIED | | | REFERENCE: | | | FBC-2004 FUEL GAS | | | FBC-2004 CHAPTER 1 | | | | | | 1. SHT P6.1 THERE ARE CHANGES TO THE GAS RISER DIAGRAM | | | THAT ARE NOT CLOUDED NOR INDICATED WITH A REVISION | | | NUMBER. EACH REVISION SHALL BE INDICATED WITH A CLOUD | | | AND A REVISION NUMBER. (SEE P19G 35,000 BTU DELETED AT | | | THE END OF LINE 2, P23G 225,000 BTU STUB OUT PIPE SIZE | | | CHANGED TO 1-1/2" LINE 2. -- SEE P17G 70,000 BTU ADDED | | | TO LINE 1, P25G 140,000 BTU DELETED FROM LINE 1). ALSO | | | CLARIFY THE P57G ON LINE 1 IS INDICATED AS 224,000 BTU, | | | BUT THE P57G ON LINE 2 IS INDICATED AS 168,000 BTU. IS | | | THIS A DIFFERENT GAS APPLIANCE? IF SO PLEASE SUBMIT THE | | | MANUF. SPECIFICATION FOR THE NEW P57G SHOWING LISTING | | | AND BTU LOAD. | | | | | | 2. SHT P6.1 SHOWS A REVISION 4 IN THE REVISION INDEX | | | THAT IS NOT SHOWN ON THE RISER DIAGRAMS. PLEASE CLARIFY | | | AS THIS REVISION HAS NOT BEEN APPROVED OR REVIEWED. | | | SECTION 106.1.1. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2008-09-23 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-09-23 |
Time |
09:27 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-09-23 |
Time |
09:27 |
Sent To |
|
|
| Notes |
| 2008-09-23 09:38:14 | | | | | | | | | | PASSED/PROVISO | | | | | | 1. SUBMIT MANUF. SPECIFICATIONS FOR ALL GAS APPLIANCES | | | AT THE TIME OF PERMIT APPLICATION SHOWING LISTING & BTU | | | LOAD. BTU LOAD SHALL REFLECT THE BTU LOAD SHOWN ON THE | | | GAS RISER ON PLANS. | | | | | | 2. PIPE SIZES FOR APPLIANCES RED LINED APPLIANCES P19G, | | | P23G & P57G SHALL BE 1-1/2" NOT 1-1/4" AS INDICATED. | | | PIPE SIZE FOR THE GAS MAIN LINE SHALL BE MINIMUM 2-1/2" | | | UPSTREAM OF APPLIANCE P24G. TABLE 402.4(2) FBC-FUEL GAS | | | -- REVISION REQUIRED. | | | | | | 3. WATER FILTER SHALL MEET NSF-42 REQUIREMENTS. MANUF. | | | SPECIFICATIONS REQUIRED AT THE TIME OF FINAL PLUMBING | | | INSPECTION. | | | | | | | | | | | | | | | | | | | | | | | | | | | . |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2008-09-22 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-08-27 |
Time |
10:07 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-08-27 |
Time |
10:07 |
Sent To |
|
|
| Notes |
| 2008-09-22 10:09:10 | DENIED | | | REFERENCE: FBC-2004 FUEL GAS | | | | | | ****FROM PREVIOUS REVIEW: | | | | | | 1. SHT P6.1 A SEPARATE GAS PERMIT IS REQUIRED. THE | | | REQUIREMENTS FOR PERMIT FOLLOW: | | | | | | A. OK | | | B. OK | | | C. OK | | | D. OK | | | E. OK | | | F. OK | | | | | | G. SUBMIT A DETAIL SHOWING THE TYPE, | | | LOCATION, SIZE AND TERMINATION OF THE | | | GAS VENTS PER FBC-2004 FUEL GAS CODE | | | SECS. 502 THRU 505. | | | ****RESPONSE NOTED, BUT COMMENT NOT ADDRESSED FOR THE | | | IWH'S. | | | | | | H. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2004 FUEL GAS CODE SEC 402.2. | | | ****RESPONSE NOTED, COMMENT NOT ADDRESSED. | | | | | | I. N/A | | | J. N/A | | | K. OK | | | | | | L. INDICATE THE PIPE SIZE FOR EACH APPLIANCE STUB-OUT | | | FROM THE BRANCH LINE. SHUT OFF VALVE SHALL BE THE SAME | | | SIZE AS THE STUB-OUT FOR THE APPLIANCE. SECTION 402. | | | ****RESPONSE NOTED, BUT PIPE SIZE AND VALVE TO EACH | | | APPLIANCE SHALL BE FULL SIZE. SEE TABLE 402.4(6). | | | | | | M. OK | | | | | | ***********NEW COMMENT*********** | | | | | | 1B. INDICATE IF THE GAS PIPING WILL BE WELDED OR SCREW | | | PIPE ON THE PLANS. IF WELDED THEN THE WELDING PROCEDURE | | | AND WELDING CERTIFICATIONS & PICTURE I.D. OF THE PERSON | | | WELDING THE PIPE ARE REQUIRED AT THE TIME OF GAS PERMIT | | | APPLICATION. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, IDENTIFYING | | | THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2008-07-09 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-07-09 |
Time |
10:05 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-07-09 |
Time |
10:05 |
Sent To |
|
|
| Notes |
| 2008-09-22 10:06:48 | DENIED | | | REFERENCE: FBC-2004 FUEL GAS | | | | | | 1. SHT P6.1 A SEPARATE GAS PERMIT IS REQUIRED. THE | | | REQUIREMENTS FOR PERMIT FOLLOW: | | | | | | A. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2004 | | | FUEL GAS CODE. | | | | | | B. SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | | NUMBER OF CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE IF BEING USED. | | | | | | C. TYPE OF GAS, (LP OR NATURAL). | | | | | | D. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES A.3.1(4). -- TO BE VERIFIED WHEN | | | COMMENT 9(A) IS ADDRESSED. | | | | | | E. SUBMIT CALCULATIONS FOR COMBUSTION | | | AIR (IF APPLICABLE) PER FBC-2004 FUEL | | | GAS CODE SECTION 304. | | | | | | F. INDICATE THE DELIVERY PRESSURE (PSI) | | | PER FBC-2004 FUEL GAS CODE SEC. 402.2. | | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. | | | | | | G. SUBMIT A DETAIL SHOWING THE TYPE, | | | LOCATION, SIZE AND TERMINATION OF THE | | | GAS VENTS PER FBC-2004 FUEL GAS CODE | | | SECS. 502 THRU 505. | | | | | | H. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2004 FUEL GAS CODE SEC 402.2. | | | | | | I. CLEARLY SHOW THE LOCATION AND CAP- | | | ACITY OF LP TANK(S), TYPE OF TANK (DOT | | | OR ASME), THE DISTANCE OF THE TANK FROM | | | THE BUILDING AND ADJACENT PROPERTY LINES | | | THE DISTANCE OF THE TANK FROM ALL SOUR- | | | CES OF IGNITION, OTHER CONTAINERS, BUILD | | | INGS, AND THE LOCATION OF ANY BUILDING | | | OPENINGS BELOW THE RELIEF VALVE OF THE | | | TANK PER NFPA 58, TABLE 3-2.2.2. | | | | | | J. CLEARLY INDICATE ON THE PLAN IF THE | | | LP TANK IS ABOVE OR BELOW GROUND, AND | | | SHOW REQUIRED PROTECTION OF THE TANK AND APPURTENANCES | | | PER NFPA 58. IF THE TANK | | | IS BELOW GROUND THE CONTAINER SHALL BE | | | SECURILY ANCHORED PER NFPA 58 SECTION | | | 3-2.2.7(H). | | | | | | K. EMERGENCY HOOD SHUT DOWN SHUT OFF | | | VALVE TO BE BELOW CEILING. MANUAL SHUT | | | OFF VALVE TO BE UPSTREAM. UNION TO BE | | | DOWN STREAM OF MANUAL VALVE. -- (NO UNIONS | | | INDICATED) | | | | | | L. INDICATE THE PIPE SIZE FOR EACH APPLIANCE STUB-OUT | | | FROM THE BRANCH LINE. SHUT OFF VALVE SHALL BE THE SAME | | | SIZE AS THE STUB-OUT FOR THE APPLIANCE. SECTION 402. | | | | | | M. SHUT OFF VALVES ARE REQUIRED FOR LINES 1 & 2 AS THEY | | | ENTER THE TENANT SPACE. SECTION 409.3.1. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, IDENTIFYING | | | THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
17 |
Status |
N |
Date |
2009-04-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-04-06 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-04-06 |
Time |
11:16 |
Sent To |
E |
|
| Notes |
| 2009-04-06 11:16:42 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
16 |
Status |
N |
Date |
2009-03-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-03-18 |
Time |
16:00 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-03-18 |
Time |
16:00 |
Sent To |
E |
|
| Notes |
| 2009-03-18 16:05:22 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
15 |
Status |
N |
Date |
2009-01-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-01-06 |
Time |
15:52 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-01-06 |
Time |
15:52 |
Sent To |
B |
|
| Notes |
| 2009-01-06 15:53:12 | TO "JWITMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
14 |
Status |
N |
Date |
2009-01-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-01-06 |
Time |
15:45 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-01-06 |
Time |
15:45 |
Sent To |
B |
|
| Notes |
| 2009-01-06 15:45:37 | TO "JWITMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
13 |
Status |
N |
Date |
2008-12-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-12-26 |
Time |
08:52 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-12-26 |
Time |
08:52 |
Sent To |
|
|
| Notes |
| 2008-12-26 08:53:06 | TO "COMM" BD#12 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2008-12-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-12-26 |
Time |
08:40 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-12-26 |
Time |
08:40 |
Sent To |
E |
|
| Notes |
| 2008-12-26 08:40:19 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2008-12-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-12-26 |
Time |
08:37 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-12-26 |
Time |
08:37 |
Sent To |
M |
|
| Notes |
| 2008-12-26 08:37:16 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2008-12-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-12-26 |
Time |
08:31 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-12-26 |
Time |
08:31 |
Sent To |
P |
|
| Notes |
| 2008-12-26 08:31:42 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2008-12-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-12-16 |
Time |
16:17 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-12-16 |
Time |
16:16 |
Sent To |
B |
|
| Notes |
| 2008-12-16 16:17:20 | TO "JWITMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2008-11-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-11-05 |
Time |
09:02 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-11-05 |
Time |
09:02 |
Sent To |
B |
|
| Notes |
| 2008-11-05 09:02:56 | TO "JWITMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2008-12-01 |
Time |
|
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2008-10-30 |
Time |
11:32 |
Sent To |
|
|
| Notes |
| 2008-10-30 11:34:11 | REVISION FOR BAR JOIST REINFORCING DETAIL TO JIM | | | WITMER'S DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2008-10-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-10-24 |
Time |
09:43 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-10-24 |
Time |
09:43 |
Sent To |
|
|
| Notes |
| 2008-10-24 09:46:04 | TO "COMM" BD#47 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2008-10-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-10-24 |
Time |
09:02 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-10-24 |
Time |
09:02 |
Sent To |
B |
|
| Notes |
| 2008-10-24 09:03:00 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2008-10-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-10-03 |
Time |
14:22 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-10-03 |
Time |
14:22 |
Sent To |
B |
|
| Notes |
| 2008-10-03 14:23:02 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-09-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-09-22 |
Time |
13:27 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-09-22 |
Time |
13:27 |
Sent To |
|
|
| Notes |
| 2008-09-22 13:34:20 | TO "COMM" BD#63--EXPEDITED-- |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-08-25 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-08-25 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
tgordon |
Date |
2008-08-25 |
Time |
14:42 |
Sent To |
|
|
| Notes |
| 2008-08-25 14:43:05 | TO "COMM" BD #39. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-07-24 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-07-24 |
Time |
15:23 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-07-03 |
Time |
14:18 |
Sent To |
|
|
| Notes |
| 2008-07-03 14:41:26 | TO "COMM" BD#24--EXPEDITED-- | | | | | | | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2009-01-07 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-01-07 |
Time |
19:46 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-01-07 |
Time |
19:44 |
Sent To |
PC |
|
| Notes |
| 2009-01-07 19:46:00 | M0.1, M2.1 AND M7.1 REV6, M6.1 REV5, |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2008-11-24 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-11-24 |
Time |
19:34 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-11-24 |
Time |
19:06 |
Sent To |
PC |
|
| Notes |
| 2008-11-24 19:34:49 | REVISED M0.1, M2.1, M6.1 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2008-09-09 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-09-09 |
Time |
08:39 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-09-09 |
Time |
08:23 |
Sent To |
|
|
| Notes |
| 2008-09-09 08:39:40 | KITCHEN EQUIPMENT PLANS SHOW NEW WALK-IN COOLERS AND/OR | | | FREEZERS. SEPARATE PERMITS ARE REQUIRED FOR THE | | | INSTALLATION OF THESE ITEMS. SUBMIT SEPARATE PLANS AND | | | SPECIFICATIONS WITH PERMIT APPLICATION. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2008-07-15 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-07-15 |
Time |
16:54 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-07-15 |
Time |
13:23 |
Sent To |
|
|
| Notes |
| 2008-07-15 15:42:32 | KITCHEN EQUIPMENT PLANS SHOW NEW WALK-IN COOLERS AND/OR | | | FREEZERS. SEPARATE PERMITS ARE REQUIRED FOR THE | | | INSTALLATION OF THESE ITEMS. SUBMIT SEPARATE PLANS AND | | | SPECIFICATIONS WITH PERMIT APPLICATION. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
7 |
Status |
P |
Date |
2009-06-25 |
|
|
Cont ID |
|
| Sent By |
dwise |
Date |
2009-06-25 |
Time |
20:01 |
Rev Time |
0.00 |
| Received By |
dwise |
Date |
2009-06-25 |
Time |
20:00 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
6 |
Status |
F |
Date |
2009-01-06 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-01-06 |
Time |
17:07 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-01-06 |
Time |
17:07 |
Sent To |
|
|
| Notes |
| 2009-01-06 17:12:05 | REVISION DENIED | | | REFERENCE: | | | FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | | | | 1. SHT P0.1 SHOWS MANY CHANGES TO THE EQUIPMENT | | | SCHEDULE THAT ARE NOT INDICATED WITH A REVISION NUMBER | | | , NOR CLOUDED AS REQUIRED. ALL REVISIONS SHALL BE | | | INDICATED WITH A CLOUD AND A REVISION NUMBER. SECTION | | | 106.1.3. -- THE REVISION INDEX SHOWS A REVISION 4 THAT | | | IS NOT INDICATED ON THE FLOOR PLAN. PLEASE CLARIFY. | | | SECTION 106.1.1. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2009-01-06 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-01-06 |
Time |
17:06 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-01-05 |
Time |
18:55 |
Sent To |
|
|
| Notes |
| 2009-01-06 17:07:27 | REVISIONS OK -- SHTS P2.1, P3.1 & P5.1 -- SHTS P2.1 & | | | P5.1 SHOW A REVISION 4 IN THE REVISION INDEX THAT WAS | | | NOT FOUND OR APPROVED. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2008-12-10 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-12-10 |
Time |
16:12 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-12-10 |
Time |
16:12 |
Sent To |
|
|
| Notes |
| 2008-12-10 16:24:30 | REVISIONS DENIED | | | REFERENCE: | | | FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1. SHTS P0.1, P2.1 & P5.1 THE PRINTED NAME OF THE | | | ENGINEER SIGNING AND SEALING THE PLANS IS REQUIRED IN | | | THE TITLE BLOCK OF EACH SHEET. (MIRCLA PELLA). FAC | | | 61G15-23.002(2) & FS 471.025. | | | | | | 2. SHT P0.1 EQUIPMENT SCHEDULE. CHANGES TO THE GAS | | | EQUIPMENT IN INDICATED. REVISIONS ARE REQUIRED FOR THE | | | FLOOR PLAN AND THE GAS ISOMETRIC RISER DIAGRAM TO | | | REFLECT THE CHANGES. SECTION 106.3.5.2. | | | | | | 3. SHT P0.1 EQUIPMENT SCHEDULE. ITEMS P85, P88C, P88H & | | | PB4.2 ARE NOT FOUND ON THE FLOOR PLAN. PLEASE | | | CORRELATE. SECTION 106.1.1. | | | | | | 4. ALL CHANGES TO THE WATER PIPING SHALL BE INDICATED | | | WITH REVISIONS TO THE FLOOR PLAN AND THE WATER | | | ISOMETRIC RISER DIAGRAM. SECTION 106.3.5.1.3. | | | | | | 5. SHT P5.1 SANITARY RISER DIAGRAM DOES NOT REFLECT THE | | | CHANGES ON THE FLOOR PLAN. UPSTREAM OF THE CONNECTION | | | TO THE RISER THERE IS A P-2 AND TWO FLOOR DRAINS SHOWN | | | ON THE FLOOR PLAN BUT NOT ON THE RISER DIAGRAM. PLEASE | | | CORRLEATE. SECTION 106.1.1. | | | | | | 6. PLEASE TURN OFF ALL PREVIOUS REVISION CLOUDS AND | | | REVISION NUMBERS FOR REVISIONS 1 & 2 AS THEY DELAY THE | | | REVIEW PROCESS. SECTION 106.1.3. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2008-09-23 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-09-23 |
Time |
09:25 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-09-22 |
Time |
15:58 |
Sent To |
|
|
| Notes |
| 2008-09-23 09:26:54 | PASSED/PROVISO -- WATER FILTER SHALL MEET THE | | | REQUIREMENTS OF NSF-42. -- MANUF. SPECIFICATIONS | | | REQUIRED AT THE TIME OF FINAL PLUMBING INSPECTION. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2008-08-27 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-08-27 |
Time |
10:30 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-08-26 |
Time |
12:58 |
Sent To |
|
|
| Notes |
| 2008-08-27 10:46:30 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 FUEL GAS | | | FBC-2004 CHAPTER 1 | | | CITY WPB MUNICIPAL CODE | | | | | | ****FROM PREVIOUS REVIEW: | | | | | | 1. SHT A120.1 CODE ANALYSIS INDICATES GROSS AREA @ | | | 15,832SF & NET AREA @ 15,304SF, BUT THE ADDITION OF THE | | | SHOWROOM, STAGE, BUSINESS, KITCHEN, BAR & WAITING AREAS | | | ONLY ADD UP TO 11, 864SF. PLEASE CLARIFY. SECTIONS 1004 | | | & 403 & TABLES 1004.1.2 & 403.1. ALSO THE COVERED PATIO | | | AREA IS NOT INCLUDED IN THE ANALYSIS. PLEASE INDICATE | | | THE OCCUPANT LOAD AND IF THERE IS SEATING IN THIS AREA. | | | SECTIONS 1004.8 & 403.1.3. | | | ****RESPONSE NOTED, BUT COMMENT NOT ADDRESSED. | | | | | | 2. SHT A120.1 PER TABLES 1004.1.2 & 403.1 & SECTION | | | 403.1.1.2, 10 WATER CLOSETS ARE REQUIRED FOR THE MEN. | | | THIS MAY CHANGE WITH THE OCCUPANCY OF THE COVERED PATIO | | | ESTABLISHED AND ADDED TO TOTAL. | | | ****RESPONSE NOTED, BUT DUE TO NEW INFORMATION | | | REQUIRED, IT IS INDICATED THAT THERE ARE "ALOT OF SEATS | | | IN THE SPACE, BUT A LOT OF PEOPLE WILL TAKE JUST A | | | DRINK (THIS IS A COMEDY CLUB)" (SEE ATTACHED SHEETS) | | | | | | 3. OK | | | | | | 4. SHT P0.1 PLUMBING SCHEDULE: ITEMS P21, P36.2, P68, | | | PB4.1 & PB4.2C SHOWN ON THE SCHEDULE WERE NOT FOUND ON | | | THE FLOOR PLAN. -- ITEM P45 INDICATES QTY 1 ON THE | | | SCHEDULE, BUT 2 WERE FOUND ON THE FLOOR PLAN. -- ITEM | | | PB1 INDICATES QTY 2 ON THE SCHEDULE, BUT 3 WERE FOUND | | | ON THE FLOOR PLAN. -- ITEM PB4C INDICATES QTY 2 ON THE | | | SCHEDULE, BUT ONLY 1 WAS FOUND ON THE FLOOR PLAN. -- | | | ITEM PB28 INDICATES QTY 5 ON THE SCHEDULE, BUT ONLY 4 | | | WERE FOUND ON THE FLOOR PLAN. PLEASE CORRELATE. SECTION | | | 106.1.1. | | | ****RESPONSE NOTED, BUT ITEMS P21 & P68 ARE STILL NOT | | | FOUND ON THE FLOOR PLAN. | | | | | | 5. OK | | | 6. OK | | | 7. OK | | | | | | 8. THE WATER FILTER INDICATED ON ITEM PB4.2C SHT P0.1 | | | SHALL MEET THE REQUIREMENTS OF NSF-42. PLEASE SUBMIT | | | MANUF. SPECIFICATION SHEETS SHOWING COMPLIANCE. | | | SECTIONS 106.1.2 & 611.1. | | | ****RESPONSE NOTED, COMMENT NOT ADDRESSED. | | | | | | 9. SHT P6.1 A SEPARATE GAS PERMIT IS REQUIRED. THE | | | REQUIREMENTS FOR PERMIT FOLLOW: | | | | | | A. OK | | | B. OK | | | C. OK | | | D. OK | | | E. OK | | | F. OK | | | | | | G. SUBMIT A DETAIL SHOWING THE TYPE, | | | LOCATION, SIZE AND TERMINATION OF THE | | | GAS VENTS PER FBC-2004 FUEL GAS CODE | | | SECS. 502 THRU 505. | | | ****RESPONSE NOTED, BUT COMMENT NOT ADDRESSED FOR THE | | | IWH'S. | | | | | | H. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2004 FUEL GAS CODE SEC 402.2. | | | ****RESPONSE NOTED, COMMENT NOT ADDRESSED. | | | | | | I. N/A | | | J. N/A | | | K. OK | | | | | | L. INDICATE THE PIPE SIZE FOR EACH APPLIANCE STUB-OUT | | | FROM THE BRANCH LINE. SHUT OFF VALVE SHALL BE THE SAME | | | SIZE AS THE STUB-OUT FOR THE APPLIANCE. SECTION 402. | | | ****RESPONSE NOTED, BUT PIPE SIZE AND VALVE TO EACH | | | APPLIANCE SHALL BE FULL SIZE. SEE TABLE 402.4(6). | | | | | | M. OK | | | | | | ***********NEW COMMENT*********** | | | | | | 1B. INDICATE IF THE GAS PIPING WILL BE WELDED OR SCREW | | | PIPE ON THE PLANS. IF WELDED THEN THE WELDING PROCEDURE | | | AND WELDING CERTIFICATIONS & PICTURE I.D. OF THE PERSON | | | WELDING THE PIPE ARE REQUIRED AT THE TIME OF GAS PERMIT | | | APPLICATION. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, IDENTIFYING | | | THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2008-07-09 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-07-09 |
Time |
11:15 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-07-07 |
Time |
15:59 |
Sent To |
|
|
| Notes |
| 2008-07-09 11:57:45 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 FUEL GAS | | | FBC-2004 CHAPTER 1 | | | CITY WPB MUNICIPAL CODE | | | | | | 1. SHT A120.1 CODE ANALYSIS INDICATES GROSS AREA @ | | | 15,832SF & NET AREA @ 15,304SF, BUT THE ADDITION OF THE | | | SHOWROOM, STAGE, BUSINESS, KITCHEN, BAR & WAITING AREAS | | | ONLY ADD UP TO 11, 864SF. PLEASE CLARIFY. SECTIONS 1004 | | | & 403 & TABLES 1004.1.2 & 403.1. ALSO THE COVERED PATIO | | | AREA IS NOT INCLUDED IN THE ANALYSIS. PLEASE INDICATE | | | THE OCCUPANT LOAD AND IF THERE IS SEATING IN THIS AREA. | | | SECTIONS 1004.8 & 403.1.3. | | | | | | 2. SHT A120.1 PER TABLES 1004.1.2 & 403.1 & SECTION | | | 403.1.1.2, 10 WATER CLOSETS ARE REQUIRED FOR THE MEN. | | | THIS MAY CHANGE WITH THE OCCUPANCY OF THE COVERED PATIO | | | ESTABLISHED AND ADDED TO TOTAL. | | | | | | 3. BECAUSE OF THE TOTAL AMOUNT OF SEATING THE UTILITY | | | DEPT., INDUSTRIAL PRETREATMENT, ENVIRONMENTAL | | | COMPLIANCE SHALL BE CONTACTED TO DETERMINE THE | | | REQUIREMENTS FOR THE GREASE INTERCEPTOR. PLEASE CONTACT | | | RODNEY (561) 644-1821, FAX (561) 822-2287 OR E-MAIL HIM | | | AT [email protected]. ARTICLE III SECTION 90-124(7). | | | | | | 4. SHT P0.1 PLUMBING SCHEDULE: ITEMS P21, P36.2, P68, | | | PB4.1 & PB4.2C SHOWN ON THE SCHEDULE WERE NOT FOUND ON | | | THE FLOOR PLAN. -- ITEM P45 INDICATES QTY 1 ON THE | | | SCHEDULE, BUT 2 WERE FOUND ON THE FLOOR PLAN. -- ITEM | | | PB1 INDICATES QTY 2 ON THE SCHEDULE, BUT 3 WERE FOUND | | | ON THE FLOOR PLAN. -- ITEM PB4C INDICATES QTY 2 ON THE | | | SCHEDULE, BUT ONLY 1 WAS FOUND ON THE FLOOR PLAN. -- | | | ITEM PB28 INDICATES QTY 5 ON THE SCHEDULE, BUT ONLY 4 | | | WERE FOUND ON THE FLOOR PLAN. PLEASE CORRELATE. SECTION | | | 106.1.1. | | | | | | 5. SHT P2.1 ITEM P48 SHALL DRAIN INTO THE SANITARY | | | SYSTEM AND NOT THE GREASE SYSTEM. ARTICLE III SECTION | | | 90-124(7)(B). PLEASE SHOW PROPER CONNECTION. | | | | | | 6. SHT P2.1 ITEM P61 INDICATED ON THE FLOOR PLAN IS NOT | | | SHOWN ON THE SCHEDULE SHT P0.1. PLEASE CORRELATE. | | | SECTION 106.1.1. | | | | | | 7. SHT P5.1 FLOOR SINK TO ITEM 48 SHALL DRAIN INTO THE | | | SANITARY SYSTEM AND NOT THE GREASE SYSTEM. ARTICLE III | | | SECTION 90-124(7)(B). PLEASE SHOW PROPER CONNECTION. | | | | | | 8. THE WATER FILTER INDICATED ON ITEM PB4.2C SHT P0.1 | | | SHALL MEET THE REQUIREMENTS OF NSF-42. PLEASE SUBMIT | | | MANUF. SPECIFICATION SHEETS SHOWING COMPLIANCE. | | | SECTIONS 106.1.2 & 611.1. | | | | | | 9. SHT P6.1 A SEPARATE GAS PERMIT IS REQUIRED. THE | | | REQUIREMENTS FOR PERMIT FOLLOW: | | | | | | A. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2004 | | | FUEL GAS CODE. | | | | | | B. SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | | NUMBER OF CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE IF BEING USED. | | | | | | C. TYPE OF GAS, (LP OR NATURAL). | | | | | | D. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES A.3.1(4). -- TO BE VERIFIED WHEN | | | COMMENT 9(A) IS ADDRESSED. | | | | | | E. SUBMIT CALCULATIONS FOR COMBUSTION | | | AIR (IF APPLICABLE) PER FBC-2004 FUEL | | | GAS CODE SECTION 304. | | | | | | F. INDICATE THE DELIVERY PRESSURE (PSI) | | | PER FBC-2004 FUEL GAS CODE SEC. 402.2. | | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. | | | | | | G. SUBMIT A DETAIL SHOWING THE TYPE, | | | LOCATION, SIZE AND TERMINATION OF THE | | | GAS VENTS PER FBC-2004 FUEL GAS CODE | | | SECS. 502 THRU 505. | | | | | | H. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2004 FUEL GAS CODE SEC 402.2. | | | | | | I. CLEARLY SHOW THE LOCATION AND CAP- | | | ACITY OF LP TANK(S), TYPE OF TANK (DOT | | | OR ASME), THE DISTANCE OF THE TANK FROM | | | THE BUILDING AND ADJACENT PROPERTY LINES | | | THE DISTANCE OF THE TANK FROM ALL SOUR- | | | CES OF IGNITION, OTHER CONTAINERS, BUILD | | | INGS, AND THE LOCATION OF ANY BUILDING | | | OPENINGS BELOW THE RELIEF VALVE OF THE | | | TANK PER NFPA 58, TABLE 3-2.2.2. | | | | | | J. CLEARLY INDICATE ON THE PLAN IF THE | | | LP TANK IS ABOVE OR BELOW GROUND, AND | | | SHOW REQUIRED PROTECTION OF THE TANK AND APPURTENANCES | | | PER NFPA 58. IF THE TANK | | | IS BELOW GROUND THE CONTAINER SHALL BE | | | SECURILY ANCHORED PER NFPA 58 SECTION | | | 3-2.2.7(H). | | | | | | K. EMERGENCY HOOD SHUT DOWN SHUT OFF | | | VALVE TO BE BELOW CEILING. MANUAL SHUT | | | OFF VALVE TO BE UPSTREAM. UNION TO BE | | | DOWN STREAM OF MANUAL VALVE. -- (NO UNIONS | | | INDICATED) | | | | | | L. INDICATE THE PIPE SIZE FOR EACH APPLIANCE STUB-OUT | | | FROM THE BRANCH LINE. SHUT OFF VALVE SHALL BE THE SAME | | | SIZE AS THE STUB-OUT FOR THE APPLIANCE. SECTION 402. | | | | | | M. SHUT OFF VALVES ARE REQUIRED FOR LINES 1 & 2 AS THEY | | | ENTER THE TENANT SPACE. SECTION 409.3.1. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, IDENTIFYING | | | THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2008-10-30 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2008-10-30 |
Time |
14:51 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
2008-10-30 |
Time |
14:51 |
Sent To |
|
|
| Notes |
| 2008-10-30 14:51:47 | RESTAMP |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2008-09-24 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2008-09-24 |
Time |
10:45 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
2008-09-24 |
Time |
10:45 |
Sent To |
|
|
| Notes |
| 2008-09-24 10:45:22 | RESTAMP |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2008-07-11 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2008-07-11 |
Time |
12:06 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
2008-07-11 |
Time |
12:06 |
Sent To |
|
|
| Notes |
|
|