| Plan Review Stops For Permit 08070087 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2008-08-21 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-08-21 |
Time |
08:26 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-08-20 |
Time |
17:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-07-25 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-07-25 |
Time |
07:28 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-07-24 |
Time |
09:58 |
Sent To |
|
|
| Notes |
| 2008-07-25 07:28:15 | BUILDING PLAN REVIEW | | | PERMIT: 08070087 | | | ADD: 400 N. FLAGLER DR. #1504 | | | CONT: A MCGILL REMODELING LLC. | | | TEL: (561)632-9354 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 7-24-08 | | | REVIEW: 1ST | | | ACTION: DENIED | | | | | | 1)INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE | | | INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | 2) FL S S 713.13 NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT. NOTE: 713.13(2) IF THE | | | WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS NOT | | | ACTUALLY COMMENCED WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) | | | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE | | | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | | | 3)INFORMATIONAL: PLANS SUBMITTED FOR PERMIT (FIRST | | | TIME REVIEW) AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO | | | THE 2004 FBC BUILDING WITH THE 2007 SUPPLEMENTS. | | | | | | 4)2004 FBC EXISTING 301.5 A DESIGN PROFESSIONAL OR AN | | | OWNER MUST ELECT ONE OR A COMBINATION OF LEVELS OF | | | ALTERATION PURSUANT TO SECTIONS 303, 304 AND 305 OF | | | THIS CODE. | | | 5)THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS | | | LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDING AND | | | SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST TO INCLUDE | | | STRUCTURAL, ELECTRIC, PLUMBING, MECHANICAL, INTERIOR | | | FINISHES, ARCHITECTURAL DESIGN FEES, MARKETING COSTS, | | | OVERHEAD AND PROFIT EXCLUDING LAND VALUE. OUR VALUATION | | | REFERENCE IS ICC (BVD) MARSHALL-SWIFT AND MEANS COST | | | ANALYSIS SERVICES PER 108.3 FBC* | | | 6)PROVIDE DETAIL ELEVATION DRAWINGS AND FRAMING | | | DETAILS FOR THE NEW WALLS AND SOFFITS INDICATING ALL | | | MATERIALS, FASTENER AND FLOOR ATTACHMENTS OF THE STUD | | | SPACING. | | | 7)THE PLANS NEED TO INDICATE THE TYPE OF BUILDING PER | | | CHAPTER 6 AND THE USE AND OCCUPANCY PER CHAPTER 3. | | | 8)FBC 1207.3 FLOOR/CEILING ASSEMBLIES BETWEEN | | | DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC | | | OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN | | | IMPACT INSULATION CLASS IIC RATING OR NOT LESS THAN 50 | | | (45 IF FIELD TESTED) WHEN IN ACCORDANCE WITH ASTM E | | | 492. PROVIDE INFORMATION ON THE SOUND PROOFING OF THE | | | FLOOR. | | | 9)FBC 106.3.5.1.1(5)* FS553.79 (2) NOW THE FIRE | | | SPRINKLER SYSTEM WILL BE ALTERED, FIRE SPRINKLER PLANS | | | ARE REQUIRED TO SHOW THE NEW LAYOUT OF THE SPRINKLER | | | HEADS. THIS INFORMATION CAN BE SHOWN ON THE CEILING | | | PLANS. | | | 10)TABLE 803.5 MINIMUM INTERIOR FINISH | | | CLASSIFICATION; PROVIDE INFORMATION BASED ON INTERIOR | | | FINISH REQUIREMENTS BASED ON OCCUPANCY | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | (561)805-6726 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2009-02-05 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-02-05 |
Time |
12:12 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-02-05 |
Time |
10:46 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2008-08-21 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-08-21 |
Time |
12:21 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-08-21 |
Time |
12:01 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2008-07-10 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-07-10 |
Time |
11:32 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-07-09 |
Time |
16:02 |
Sent To |
|
|
| Notes |
| 2008-07-10 10:36:43 | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE | | | CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2004 | | | RESIDENTIAL BUILDING CODE, 2005 NEC, 2004 FBC CHAPTER 1 | | | AS AMENDED AND FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | ALL COMMENTS RELATE TO SHEET-3 UNLESS OTHERWISE NOTED. | | | ALL CODE ARTICLES REFERENCED ARE 2005 NEC UNLESS | | | OTHERWISE NOTED. | | | | | | 1} BATH CIRCUIT REQUIRED TO HAVE A 20 AMP RECEPTACLE | | | PER 210.11(C) (3), CIRCUIT #14 DOES NOT COMPLY. | | | | | | 2} CIRCUIT #15 APPEARS AT THE KITCHEN COUNTER AS WELL | | | AS THE WASHER IN VIOLATION OF 210.52(B)(1) "RECEPTACLE | | | OUTLETS SERVED IN THE KITCHEN, PANTRY, BREAKFAST ROOM, | | | DINING ROOM, OR SIMILAR AREA OF A DWELLING UNIT, THE | | | TWO OR MORE 20-AMPERE SMALL-APPLIANCE BRANCH CIRCUITS | | | REQUIRED BY 210.11(C)(1) SHALL SERVE ALL WALL AND FLOOR | | | RECEPTACLE OUTLETS COVERED BY 210.52(A), ALL COUNTERTOP | | | OUTLETS COVERED BY 210.52(C), AND RECEPTACLE OUTLETS | | | FOR REFRIGERATION EQUIPMENT.". | | | | | | 3} KITCHEN RECEPTACLE SPACING MUST COMPLY WITH | | | 210.52(A), 210.52(C), AND 210.8(A)(6) GFI.THERE IS NO | | | RECEPTACLES SHOWN INDICATING COUTERTOP REQUIREMENTS. | | | | | | 4} THE DESIGN PROFESSIONAL OR OWNER MUST ELECT THE | | | LEVEL OF ALTERATION PURSUANT TO SECTIONS 303, 304 AND | | | 305 OF THE EXISTING BUILDING CODE. PLEASE DECLARE SAME | | | ON THE PLAN. | | | | | | 5} NOTE #20 INDICATES CUTTING THE STRUCTURE. PROVIDE | | | ENGINEERING INDICATING THE STRUCTURAL INTEGRITY OF THE | | | CEILING OR FLOOR ABOVE WILL NOT BE COMPROMISED, SIGNED | | | AND SEALED. | | | | | | 6} SEE THE DEFINITION OF "SMOKE DETECTORS" 11.8.2.1 | | | NFPA-72, CLARIFY IF USING DETECTORS OR ALARMS, TO AVOID | | | CONFUSION IN THE FIELD. IF USING DETECTORS INDICATE THE | | | LOCATIONS OF THE SOUNDING DEVICES. | | | | | | 7} PER 2704.1, 2004 FBC, METAL FRAMING MEMBERS SHALL BE | | | BONDED TO THE EQUIPMENT GROUNDING CONDUCTOR FOR THE | | | CIRCUIT THAT MAY ENERGIZE THE FRAMING. PLEASE SEE | | | ARTICLE, PUT A ON THE PLAN FOR CLARITY IN THE FIELD. | | | | | | 8} FOR RECORD RETENTION PER 106.5 FBC, AND CLARITY IN | | | THE FIELD WHEN WORKING FROM THIS DOCUMENT, PLEASE | | | INDICATE THE CODE CYCLES UNDER WHICH THIS PLAN WAS | | | DESIGNED. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2008-08-18 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-08-18 |
Time |
12:43 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-08-18 |
Time |
12:33 |
Sent To |
|
|
| Notes |
| 2008-08-18 12:43:42 | *****APPROVED***** | | | | | | | | | THE COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEW HAVE | | | BEEN ADDRESSED;PLAN SHEETS A-1 AND A-3 WERE STAMPED, | | | INITIALED, AND DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2008-07-22 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-07-22 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-07-22 |
Time |
10:00 |
Sent To |
|
|
| Notes |
| 2008-07-22 10:06:12 | ***DENIED*** | | | | | | 1) SEE ELECTRICAL COMMENT #6 AND MAKE CORRECTIONS IF | | | APPLICABLE. SMOKE DETECTORS ARE TIED TO A FIRE ALARM | | | SYSTEM AND DETECT PARTICLES OF COMBUSTION WHEREAS SMOKE | | | ALARMS NOTIFY OCCUPANTS BY WAY OF AN AUDIBLE ALARM. | | | | | | 2) IN ADDITION TO APPLICABLE BUILDING CODES, LIFE | | | SAFETY TO COMPLY WITH NFPA 101, 2003 EDITION. | | | | | | 3) CONSTRUCTION, ALTERATION AND DEMOLITION TO COMPLY | | | WITH NFPA 241. | | | | | | 4) SEPARATE SHOP DRAWINGS AND PERMIT REQUIRED FOR FIRE | | | SPRINKLER REMODEL. | | | | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | | FIRE PLAN REVIEW | | | FIRE PREVENTION (561) 804-4756 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2009-02-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-02-05 |
Time |
08:37 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-02-05 |
Time |
08:37 |
Sent To |
E |
|
| Notes |
| 2009-02-05 08:37:54 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-08-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-08-06 |
Time |
10:27 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-08-06 |
Time |
10:27 |
Sent To |
|
|
| Notes |
| 2008-08-12 13:33:11 | TO "BOB"#3 | | 2008-08-06 10:27:29 | WAITING FOR "BOB" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-07-25 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-07-25 |
Time |
15:55 |
Rev Time |
0.00 |
| Received By |
tgordon |
Date |
2008-07-02 |
Time |
15:52 |
Sent To |
|
|
| Notes |
| 2008-07-02 15:55:11 | TO "BOB"#8 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2008-07-25 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-07-25 |
Time |
15:54 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2008-07-25 |
Time |
15:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2008-08-13 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-08-13 |
Time |
14:25 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-08-13 |
Time |
14:25 |
Sent To |
|
|
| Notes |
| 2008-08-13 14:26:58 | NOTE: FIXTURE CHANGE OUT ONLY. | | | | | | ***************PROVISO**************** | | | PER FBC-2004 PLUMBING, SECTION 704.5 DEAD ENDS: IN THE | | | REMOVAL OF ANY PART OF A DRAINAGE SYSTEM, DEAD ENDS | | | SHALL BE PROHIBITED. A PLUMBING PERMIT IS REQUIRED AND | | | AN INSPECTION IS REQUIRED OF PLUMBING DEMO WORK PRIOR | | | TO COVERING DEMO WORK WITH FINNISH WALLS, CIELINGS, OR | | | POURED CONCRETE SLABS. | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2008-07-25 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-07-25 |
Time |
13:54 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-07-25 |
Time |
13:54 |
Sent To |
|
|
| Notes |
| 2008-07-25 14:34:29 | PLUMBING PLAN REVIEW: | | | DENIED: | | | | | | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | | PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE. | | | | | | 1. DECLARE THE GOVERNING CODE. (FBC-2004 WITH 2007 | | | REVISIONS) PER (W.P.B. AS AMENDED) SECTION 106.5 | | | RETENTION OF CONSTRUCTION DOCUMENTS. | | | | | | 2. DECLARE THE LEVEL OF ALTERATION. PER FBC-2004 | | | EXISTING BUILDING CHAPTER 3. | | | | | | 3. THE VALUE ON THE PERMIT APPLICATION APPEARS LOW. | | | THE VALUE ON THE PERMIT APPLICATION MUST INCLUDE THE | | | TOTAL COST OF LABOR AND MATERIALS. VALUATION REFERENCES | | | MAY INCLUDE THE LATEST PUBLISHED DATA OF A NATIONAL | | | CONSTRUCTION COST ANALYSIS (MARSHALL-SWIFT, MEANS, | | | ECT...) ADJUST THE VALUE AT THE PERMIT CLERK'S DESK AND | | | PAY THE DIFFERENCE IN FEES PRIOR TO RESUBMITTING OR | | | PROVIDE A COPY OF THE SIGNED CONRACT BY BOTH PARTIES | | | (CONTRACTOR AND CUSTOMER) TO VERIFY THE PERMIT | | | APPLICATION VALUE. PER (W.P.B. AS AMENDED) SECTION | | | 108.3 BUILDING PERMIT VALUATION. | | | | | | ********IMPORTANT INFORMATION******** | | | WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE | | | OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW | | | PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | PHONE= (561) 805-6730 | | | FAX= (561) 805-6731 | | | E-MAIL= [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2008-07-07 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-07-07 |
Time |
13:30 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-07-07 |
Time |
13:30 |
Sent To |
|
|
| Notes |
| 2008-07-07 13:30:18 | *ZONING REVIEW NOT REQUIRED: INTERIOR WORK ONLY AND THE | | | VALUE OF PROPOSED WORK DOES NOT EXCEED 50% OF THE | | | IMPROVEMENT VALUE. |
|
|