Plan Review Details - Permit 08060778
Plan Review Stops For Permit 08060778
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2009-05-11 Cont ID  
Sent By rmcdouga Date 2009-05-11 Time 15:37 Rev Time 0.00
Received By rmcdouga Date 2009-05-11 Time 15:37 Sent To  
Notes
2009-05-11 15:40:05REVISED SHEETS CO.1, A.01, A.02, A.03, A.04, A.04B,
 A.05 AND A.O6 HAVE BEEN REVIEWED FOR COMPLIANCE WITH
 2004 FBC.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2009-01-08 Cont ID  
Sent By rmcdouga Date 2009-01-08 Time 13:39 Rev Time 0.00
Received By rmcdouga Date 2009-01-08 Time 13:39 Sent To  
Notes
2009-01-08 13:40:58REVISED SHEETS A.01, A.02, A.03, S.01, S.02 AND S.03
 ARE OK.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2008-10-10 Cont ID  
Sent By rmcdouga Date 2008-10-10 Time 13:39 Rev Time 0.00
Received By rmcdouga Date 2008-10-10 Time 13:39 Sent To  
Notes
2008-10-10 13:44:52BUILDING PROVISO
  
 SUBMIT TWO COPIES OF PRODUCT APPROVALS THAT HAVE BEEN
 REVIEWED AND APPROVED BY THE DESIGNER OF RECORD FOR THE
 WINDOW MULLIONS AND 8" CONCRETE LINTELS.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-07-22 Cont ID  
Sent By rmcdouga Date 2008-07-22 Time 13:30 Rev Time 0.00
Received By rmcdouga Date 2008-07-22 Time 13:30 Sent To  
Notes
2008-07-22 13:11:332004 FBC W/2007 REVISIONS
 POOL CABANA
  
 DENIED BY BUILDING
  
 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT WILL
 BE REQUIRED.
  
 2) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 3) THE OWNER/AGENT IS REQUIRED TO SIGN THE ENERGY
 CALCULATION FORMS PER FBC CHAPTER 13.
  
 4) IN ORDER TO CLAIM THE CEILING FAN CREDIT ON THE
 ENERGY CALCULATIONS, THE PLANS ARE REQUIRED TO SHOW THE
 REQUIRED CEILING FAN SIZES AND LOCATIONS. SEE FBC
 13-600.
  
 5) SPECIFY THE WATER HEATER ON THE ENERGY CALCULATIONS.
 SEE FBC 13-600.
  
 6) THE STRUCTURAL PLANS ARE REQUIRED TO BE SIGNED,
 SEALED AND DATED BY THE ENGINEER AS REQUIRED BYFS 471
 AND FAC 61G15-23.002.
  
 7) THE SOIL REPORT IS REQUIRED TO HAVE THE ORIGINAL
 SIGNATURE OF THE ENGINEER. SIGNATURE STAMPS AND
 PHOTOCOPIED SIGNATURES ARE NOT ACCEPTABLE. SEE FS 471
 AND FAC 61G15-23.002.
  
 8) THE TRUSS DRAWINGS ARE REQUIRED TO HAVE THE ORIGINAL
 SIGNATURE OF THE TRUSS ENGINEER. A COVER SHEET IN
 COMPLIANCE WITH FAC 61G15-23.002 MAY BE USED. SEE FS
 471 AND FAC 61G15-23.002.
  
 9) THE TRUSS LAYOUT IS REQUIRED TO BE REVIEWED AND
 APPROVED BY THE DESIGNER OF RECORD FOR THE STRUCTURE.
 SEE FBC R301.1. PLEASE HAVE THE DESIGNER OF RECORD PUT
 HIS SHOP DRAWING REVIEW STAMP OR OTHERWISE INDICATE ON
 THE TRUSS LAYOUT THAT THEY HAVE BEEN REVIEWED AND
 APPROVED.
  
 10) SUBMIT TWO COPIES OF PRODUCT APPROVALS AS REQUIRED
 BY DCA RULE 9B-72 FOR THE LINTELS, STRUCTURAL WINDOW
 MULLIONS, AND FIXED GLASS WINDOWS (ROUND, ARCH TOP &
 RECTANGLE).
  
 11) SUBMIT THE INSTALLATION INSTRUCTIONS FOR THE SINGLE
 AND DOUBLE OUTSWING GLAZED DOORS AS REQUIRED BY RULE
 9B-72. PLEASE PROVIDE ONE OF EACH DOOR TYPE WITH EACH
 SET OF PLANS. BOTH THE SINGLE DOOR PRODUCT APPROVALS
 WERE ATTACHED TO A PLAN AND BOTH THE DOUBLE DOOR
 APPROVALS WERE ATTACHED TO THE OTHER PLAN.
  
 12) SPECIFY WHICH ONE OF THE METHODS LISTED IN THE
 ROOFINGPRODUCT APPROVAL WILL BE USED TO ATTACH THE
 ROOF TILES. CIRCLE THE ONE THAT WILL BE USED ON THE
 NOAS. FBC R905.3.7.
  
 NOTE: PLEASE DO NOT STAPLE THE PRODUCT APPROVALS AND
 OTHER DOCUMENTS TO THE PLANS.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2009-05-07 Cont ID  
Sent By btrobaug Date 2009-05-07 Time 17:00 Rev Time 0.00
Received By btrobaug Date 2009-05-07 Time 17:00 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2008-11-06 Cont ID  
Sent By btrobaug Date 2008-11-06 Time 08:55 Rev Time 0.00
Received By btrobaug Date 2008-11-06 Time 07:49 Sent To PC
Notes
2008-11-06 08:55:46 
  
  
  
  
  
  
 PROVISO
  
 SHEET E-2 MUST BE REVISED ON THE BASE BUILDING PERMIT
 AS THAT PERMIT IS IN AN OPEN STATUS PRIOR TO
 INSTALLATION OF THE 600 AMP SERVICE SHOWN ON THIS PLAN.
 THE PERMITTED SET OF PLANS INDICATES A 400 AMP SERVICE
 AND THE RISER SUBMITTED FOR THIS PERMIT HAS A 600 AMP
 SERVICE
  

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2008-10-03 Cont ID  
Sent By btrobaug Date 2008-10-03 Time 16:41 Rev Time 0.00
Received By btrobaug Date 2008-10-03 Time 16:16 Sent To P
Notes
2008-10-03 16:40:59 
  
  
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES:
  
 THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2004
 RESIDENTIAL BUILDING CODE, 2005 NEC, 2004 FBC CHAPTER 1
 AS AMENDED AND FOUND NONCOMPLIANT WITH THE FOLLOWING:
  
 REPEAT COMMENT:
  
 1} SHEET E-2 MUST BE REVISED ON THE BASE BUILDING
 PERMIT AS THAT PERMIT IS IN AN OPEN STATUS. THE
 PERMITTED SET OF PLANS INDICATES A 400 AMP SERVICE AND
 THE RISER SUBMITTED FOR THIS PERMIT HAS A 600 AMP
 SERVICE.THERE ARE SEVERAL INCONSISTENCIES BETWEEN THE
 TWO SETS OF PLANS. PLEASE VERIFY THAT THE SET SUBMITTED
 WAS THE ONE INTENDED TO BE SUBMITTED.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2008-06-30 Cont ID  
Sent By btrobaug Date 2008-06-30 Time 11:48 Rev Time 0.00
Received By btrobaug Date 2008-06-30 Time 08:48 Sent To P
Notes
2008-06-30 11:48:09 
  
  
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE
 CYCLES:
  
 THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2004
 RESIDENTIAL BUILDING CODE, 2005 NEC, 2004 FBC CHAPTER 1
 AS AMENDED AND FOUND NONCOMPLIANT WITH THE FOLLOWING:
  
 1} SHEET E-2 MUST BE REVISED ON THE BASE BUILDING
 PERMIT AS THAT PERMIT IS IN AN OPEN STATUS. THE
 PERMITTED SET OF PLANS INDICATES A 400 AMP SERVICE AND
 THE RISER SUBMITTED FOR THIS PERMIT HAS A 600 AMP
 SERVICE.THERE ARE SEVERAL INCONSISTENCIES BETWEEN THE
 TWO SETS OF PLANS. PLEASE VERIFY THAT THE SET SUBMITTED
 WAS THE ONE INTENDED TO BE SUBMITTED.
  
 REGARDING SHEET A-6:
  
 2} THE WATER HEATER AND AHU DISCONNECTS DO NOT COMPLY
 WITH 110.26 SPACING REQUIREMENTS AS SHOWN ON THE PLAN.
  
 3} THE 100 AMP DISCONNECT MUST COMPLY WITH 250.32 WHICH
 WOULD BE SHOWN ON THE CORRECTED RISER SHEET E-2.
  
 4} SEE THE DEFINITION OF "SMOKE DETECTORS" 11.8.2.1
 NFPA-72, CLARIFY IF USING DETECTORS OR ALARMS, TO AVOID
 CONFUSION IN THE FIELD. IF USING DETECTORS INDICATE THE
 LOCATIONS OF THE SOUNDING DEVICES.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2009-04-29 Cont ID  
Sent By dpalmer Date 2009-04-29 Time 09:08 Rev Time 0.00
Received By dpalmer Date 2009-04-29 Time 09:08 Sent To  
Notes
2009-04-29 09:08:45TO R-15

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2009-04-20 Cont ID  
Sent By swurafti Date 2009-04-20 Time 16:40 Rev Time 0.00
Received By swurafti Date 2009-04-20 Time 16:40 Sent To E
Notes
2009-04-20 16:41:32TO "BTROBAUGH" DESK

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2009-02-06 Cont ID  
Sent By adarroug Date 2009-02-06 Time 10:16 Rev Time 0.00
Received By adarroug Date 2009-02-06 Time 10:16 Sent To M
Notes
2009-02-06 10:16:50TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2008-12-19 Cont ID  
Sent By adarroug Date 2008-12-19 Time 11:35 Rev Time 0.00
Received By adarroug Date 2008-12-19 Time 11:35 Sent To B
Notes
2008-12-19 11:37:00TO "RMCDOUGAL" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-09-23 Cont ID  
Sent By adarroug Date 2008-09-23 Time 11:53 Rev Time 0.00
Received By adarroug Date 2008-09-23 Time 11:53 Sent To Z
Notes
2008-09-23 11:58:42TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-07-22 Cont ID  
Sent By rmcdouga Date 2008-07-22 Time 13:30 Rev Time 0.00
Received By rmcdouga Date 2008-06-26 Time 16:30 Sent To  
Notes
2008-06-26 16:32:05TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2009-02-11 Cont ID  
Sent By hmoser Date 2009-02-11 Time 11:01 Rev Time 0.00
Received By hmoser Date 2009-02-11 Time 11:01 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2008-10-07 Cont ID  
Sent By tgordon Date 2008-10-07 Time 09:33 Rev Time 0.45
Received By tgordon Date 2008-10-07 Time 09:33 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2008-06-27 Cont ID  
Sent By tgordon Date 2008-06-27 Time 16:33 Rev Time 0.30
Received By tgordon Date 2008-06-27 Time 16:33 Sent To E
Notes
2008-06-27 16:39:04PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM
 BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA
 ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES
 (F.S.).
  
 *** DENIED ***
 1) ENERGY CALCULATIONS NEED TO BE SIGNED BY OWNER/AGENT
 ALSO, PER 2004 FBC 13-103.3.
  
 2) THE COOLING LOAD CALCULATIONS NEED TO BE THE LONG
 FORM, PER 2004 FBC 13-607.1.ABC.1.
  
 3) THE MECHANICAL PLAN NEEDS THE JOB ADDRESS ON THEM,
 PER 2004 WPB AMEND. 106.1.3.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]

Review Stop P PLUMBING
Rev No 3 Status P Date 2009-05-01 Cont ID  
Sent By kstevens Date 2009-05-01 Time 12:00 Rev Time 0.00
Received By kstevens Date 2009-05-01 Time 12:00 Sent To  
Notes
2009-05-01 12:01:16REVISION OK -- SANITARY RISER DIAGRAM SHT A-06

Review Stop P PLUMBING
Rev No 2 Status P Date 2008-10-06 Cont ID  
Sent By mperson Date 2008-10-06 Time 15:45 Rev Time 0.30
Received By mperson Date 2008-10-06 Time 15:45 Sent To M
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2008-07-03 Cont ID  
Sent By mperson Date 2008-07-03 Time 09:26 Rev Time 0.00
Received By mperson Date 2008-07-03 Time 09:26 Sent To B
Notes
2008-07-03 09:58:18PLUMBING PLAN REVIEW:
 DENIED:
  
 PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH
 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO
 CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE
 (F.A.C.), AND FLORIDA STATUTES (F.S.).
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 GAS/PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE.
  
 1. THE ENERGY CALCULATIONS NEED TO BE SIGNED BY
 OWNER/AGENT, PER FBC- 2004 SECTION 13-103.3.
  
 2. THE ENERGY CALCULATIONS FAIL TO HAVE THE WATER
 HEATER. THE NEW WATER HEATER FOR THE CABANA SHALL
 COMPLY WITH FBC- 2004 TABLE 13-612.1.ABC.3.2 MINIMUM
 PERFORMANCE STANDARDS WATER HEATING EQUIPMENT.
  
 3. SHEET A-06 POOL CABANA PLUMBING RISER. PLEASE
 CORRECT THE SANITARY RISER DIAGRAM PER FBC- PLUMBING
 THE FOLLOWING SECTIONS.
  
 A} 917.7 VENT REQUIRED. WITHIN EACH PLUMBING SYSTEM, A
 MINIMUM OF ONE VENT OR VENT STACK SHALL EXTEND OUTDOORS
 TO THE OPEN AIR. THE SUBMITTED RISER DIAGRAM INDICATES
 TWO STUDOR VENTS BEING INSTALLED WITH NO VENT OUTDOORS
 TO OPEN AIR.
  
 B} PLEASE CLEARLY INDICATE THE CLEANOUT AT THE
 JUNCTION OF THE BUILDING DRAIN AND BUILDING SEWER AS
 BEING A TWO-WAY CLEANOUT. PER SECTION 708.3.5.
  
 ********IMPORTANT INFORMATION********
 WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE
 OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW
 PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 END OF COMMENTS:
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 PHONE= (561) 805-6730
 FAX= (561) 805-6731
 E-MAIL= [email protected]

Review Stop Z ZONING
Rev No 3 Status P Date 2009-05-14 Cont ID  
Sent By mcruz Date 2009-05-14 Time 13:54 Rev Time 0.00
Received By mcruz Date 2009-05-14 Time 11:56 Sent To  
Notes
2009-05-14 13:51:13NO 220V CONNECTIONS SHALL BE INSTALLED NOR A SEPARATE
 IN ACCESSORY STRUCTURE - POOL CABANA.
  
 MAGGIE CRUZ, ASSOCIATE PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: (561) 822-1444 OR (561) 805-6720
 E-MAIL: [email protected]
  
  

Review Stop Z ZONING
Rev No 2 Status P Date 2008-10-01 Cont ID  
Sent By mcruz Date 2008-10-01 Time 10:52 Rev Time 0.00
Received By mcruz Date 2008-10-01 Time 10:52 Sent To E
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2008-06-27 Cont ID  
Sent By choops Date 2008-06-27 Time 14:29 Rev Time 0.00
Received By choops Date 2008-06-27 Time 14:29 Sent To E
Notes
2008-06-27 14:32:37***FAILED***
  
  
 1)INDICATE SETBACK DIMENSIONS FROM PROPOSED A/C
 EQUIPMENT TO ALL PROPERTY LINES.AS PER SECTION
 94-305(B)(4) OF THE CITY'S ZONING AND LAND DEVELOPMENT
 REGULATIONS (ZLDRS): MECHANICAL EQUIPMENT MAY NOT
 PROJECT MORE THAN 4 FEET INTO A REQUIRED SETBACK.
  
 2)PROVIDE BEAR LAKES HOA APPROVAL.
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS,
 ZONING TECHNICIAN (561)805-6720
 [email protected]
  
  
  
  
 SENT TO "E" - SF RACK