| Plan Review Stops For Permit 08060778 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2009-05-11 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2009-05-11 |
Time |
15:37 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2009-05-11 |
Time |
15:37 |
Sent To |
|
|
| Notes |
| 2009-05-11 15:40:05 | REVISED SHEETS CO.1, A.01, A.02, A.03, A.04, A.04B, | | | A.05 AND A.O6 HAVE BEEN REVIEWED FOR COMPLIANCE WITH | | | 2004 FBC. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2009-01-08 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2009-01-08 |
Time |
13:39 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2009-01-08 |
Time |
13:39 |
Sent To |
|
|
| Notes |
| 2009-01-08 13:40:58 | REVISED SHEETS A.01, A.02, A.03, S.01, S.02 AND S.03 | | | ARE OK. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2008-10-10 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2008-10-10 |
Time |
13:39 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2008-10-10 |
Time |
13:39 |
Sent To |
|
|
| Notes |
| 2008-10-10 13:44:52 | BUILDING PROVISO | | | | | | SUBMIT TWO COPIES OF PRODUCT APPROVALS THAT HAVE BEEN | | | REVIEWED AND APPROVED BY THE DESIGNER OF RECORD FOR THE | | | WINDOW MULLIONS AND 8" CONCRETE LINTELS. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-07-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2008-07-22 |
Time |
13:30 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2008-07-22 |
Time |
13:30 |
Sent To |
|
|
| Notes |
| 2008-07-22 13:11:33 | 2004 FBC W/2007 REVISIONS | | | POOL CABANA | | | | | | DENIED BY BUILDING | | | | | | 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT WILL | | | BE REQUIRED. | | | | | | 2) IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | COPY OF RECEIPT SUBMITTED TO CITY OF | | | WEST PALM BEACH BUILDING DEPARTMENT, | | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | | | 3) THE OWNER/AGENT IS REQUIRED TO SIGN THE ENERGY | | | CALCULATION FORMS PER FBC CHAPTER 13. | | | | | | 4) IN ORDER TO CLAIM THE CEILING FAN CREDIT ON THE | | | ENERGY CALCULATIONS, THE PLANS ARE REQUIRED TO SHOW THE | | | REQUIRED CEILING FAN SIZES AND LOCATIONS. SEE FBC | | | 13-600. | | | | | | 5) SPECIFY THE WATER HEATER ON THE ENERGY CALCULATIONS. | | | SEE FBC 13-600. | | | | | | 6) THE STRUCTURAL PLANS ARE REQUIRED TO BE SIGNED, | | | SEALED AND DATED BY THE ENGINEER AS REQUIRED BYFS 471 | | | AND FAC 61G15-23.002. | | | | | | 7) THE SOIL REPORT IS REQUIRED TO HAVE THE ORIGINAL | | | SIGNATURE OF THE ENGINEER. SIGNATURE STAMPS AND | | | PHOTOCOPIED SIGNATURES ARE NOT ACCEPTABLE. SEE FS 471 | | | AND FAC 61G15-23.002. | | | | | | 8) THE TRUSS DRAWINGS ARE REQUIRED TO HAVE THE ORIGINAL | | | SIGNATURE OF THE TRUSS ENGINEER. A COVER SHEET IN | | | COMPLIANCE WITH FAC 61G15-23.002 MAY BE USED. SEE FS | | | 471 AND FAC 61G15-23.002. | | | | | | 9) THE TRUSS LAYOUT IS REQUIRED TO BE REVIEWED AND | | | APPROVED BY THE DESIGNER OF RECORD FOR THE STRUCTURE. | | | SEE FBC R301.1. PLEASE HAVE THE DESIGNER OF RECORD PUT | | | HIS SHOP DRAWING REVIEW STAMP OR OTHERWISE INDICATE ON | | | THE TRUSS LAYOUT THAT THEY HAVE BEEN REVIEWED AND | | | APPROVED. | | | | | | 10) SUBMIT TWO COPIES OF PRODUCT APPROVALS AS REQUIRED | | | BY DCA RULE 9B-72 FOR THE LINTELS, STRUCTURAL WINDOW | | | MULLIONS, AND FIXED GLASS WINDOWS (ROUND, ARCH TOP & | | | RECTANGLE). | | | | | | 11) SUBMIT THE INSTALLATION INSTRUCTIONS FOR THE SINGLE | | | AND DOUBLE OUTSWING GLAZED DOORS AS REQUIRED BY RULE | | | 9B-72. PLEASE PROVIDE ONE OF EACH DOOR TYPE WITH EACH | | | SET OF PLANS. BOTH THE SINGLE DOOR PRODUCT APPROVALS | | | WERE ATTACHED TO A PLAN AND BOTH THE DOUBLE DOOR | | | APPROVALS WERE ATTACHED TO THE OTHER PLAN. | | | | | | 12) SPECIFY WHICH ONE OF THE METHODS LISTED IN THE | | | ROOFINGPRODUCT APPROVAL WILL BE USED TO ATTACH THE | | | ROOF TILES. CIRCLE THE ONE THAT WILL BE USED ON THE | | | NOAS. FBC R905.3.7. | | | | | | NOTE: PLEASE DO NOT STAPLE THE PRODUCT APPROVALS AND | | | OTHER DOCUMENTS TO THE PLANS. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2009-05-07 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-05-07 |
Time |
17:00 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-05-07 |
Time |
17:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2008-11-06 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-11-06 |
Time |
08:55 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-11-06 |
Time |
07:49 |
Sent To |
PC |
|
| Notes |
| 2008-11-06 08:55:46 | | | | | | | | | | | | | | | | | | | | | | PROVISO | | | | | | SHEET E-2 MUST BE REVISED ON THE BASE BUILDING PERMIT | | | AS THAT PERMIT IS IN AN OPEN STATUS PRIOR TO | | | INSTALLATION OF THE 600 AMP SERVICE SHOWN ON THIS PLAN. | | | THE PERMITTED SET OF PLANS INDICATES A 400 AMP SERVICE | | | AND THE RISER SUBMITTED FOR THIS PERMIT HAS A 600 AMP | | | SERVICE | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2008-10-03 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-10-03 |
Time |
16:41 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-10-03 |
Time |
16:16 |
Sent To |
P |
|
| Notes |
| 2008-10-03 16:40:59 | | | | | | | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2004 | | | RESIDENTIAL BUILDING CODE, 2005 NEC, 2004 FBC CHAPTER 1 | | | AS AMENDED AND FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | | | | REPEAT COMMENT: | | | | | | 1} SHEET E-2 MUST BE REVISED ON THE BASE BUILDING | | | PERMIT AS THAT PERMIT IS IN AN OPEN STATUS. THE | | | PERMITTED SET OF PLANS INDICATES A 400 AMP SERVICE AND | | | THE RISER SUBMITTED FOR THIS PERMIT HAS A 600 AMP | | | SERVICE.THERE ARE SEVERAL INCONSISTENCIES BETWEEN THE | | | TWO SETS OF PLANS. PLEASE VERIFY THAT THE SET SUBMITTED | | | WAS THE ONE INTENDED TO BE SUBMITTED. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2008-06-30 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-06-30 |
Time |
11:48 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-06-30 |
Time |
08:48 |
Sent To |
P |
|
| Notes |
| 2008-06-30 11:48:09 | | | | | | | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE | | | CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2004 | | | RESIDENTIAL BUILDING CODE, 2005 NEC, 2004 FBC CHAPTER 1 | | | AS AMENDED AND FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | | | | 1} SHEET E-2 MUST BE REVISED ON THE BASE BUILDING | | | PERMIT AS THAT PERMIT IS IN AN OPEN STATUS. THE | | | PERMITTED SET OF PLANS INDICATES A 400 AMP SERVICE AND | | | THE RISER SUBMITTED FOR THIS PERMIT HAS A 600 AMP | | | SERVICE.THERE ARE SEVERAL INCONSISTENCIES BETWEEN THE | | | TWO SETS OF PLANS. PLEASE VERIFY THAT THE SET SUBMITTED | | | WAS THE ONE INTENDED TO BE SUBMITTED. | | | | | | REGARDING SHEET A-6: | | | | | | 2} THE WATER HEATER AND AHU DISCONNECTS DO NOT COMPLY | | | WITH 110.26 SPACING REQUIREMENTS AS SHOWN ON THE PLAN. | | | | | | 3} THE 100 AMP DISCONNECT MUST COMPLY WITH 250.32 WHICH | | | WOULD BE SHOWN ON THE CORRECTED RISER SHEET E-2. | | | | | | 4} SEE THE DEFINITION OF "SMOKE DETECTORS" 11.8.2.1 | | | NFPA-72, CLARIFY IF USING DETECTORS OR ALARMS, TO AVOID | | | CONFUSION IN THE FIELD. IF USING DETECTORS INDICATE THE | | | LOCATIONS OF THE SOUNDING DEVICES. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2009-04-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-04-29 |
Time |
09:08 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-04-29 |
Time |
09:08 |
Sent To |
|
|
| Notes |
| 2009-04-29 09:08:45 | TO R-15 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2009-04-20 |
|
|
Cont ID |
|
| Sent By |
swurafti |
Date |
2009-04-20 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
swurafti |
Date |
2009-04-20 |
Time |
16:40 |
Sent To |
E |
|
| Notes |
| 2009-04-20 16:41:32 | TO "BTROBAUGH" DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2009-02-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-02-06 |
Time |
10:16 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-02-06 |
Time |
10:16 |
Sent To |
M |
|
| Notes |
| 2009-02-06 10:16:50 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-12-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-12-19 |
Time |
11:35 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-12-19 |
Time |
11:35 |
Sent To |
B |
|
| Notes |
| 2008-12-19 11:37:00 | TO "RMCDOUGAL" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-09-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-09-23 |
Time |
11:53 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-09-23 |
Time |
11:53 |
Sent To |
Z |
|
| Notes |
| 2008-09-23 11:58:42 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-07-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2008-07-22 |
Time |
13:30 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2008-06-26 |
Time |
16:30 |
Sent To |
|
|
| Notes |
| 2008-06-26 16:32:05 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2009-02-11 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2009-02-11 |
Time |
11:01 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2009-02-11 |
Time |
11:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2008-10-07 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-10-07 |
Time |
09:33 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2008-10-07 |
Time |
09:33 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2008-06-27 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-06-27 |
Time |
16:33 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2008-06-27 |
Time |
16:33 |
Sent To |
E |
|
| Notes |
| 2008-06-27 16:39:04 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | *** DENIED *** | | | 1) ENERGY CALCULATIONS NEED TO BE SIGNED BY OWNER/AGENT | | | ALSO, PER 2004 FBC 13-103.3. | | | | | | 2) THE COOLING LOAD CALCULATIONS NEED TO BE THE LONG | | | FORM, PER 2004 FBC 13-607.1.ABC.1. | | | | | | 3) THE MECHANICAL PLAN NEEDS THE JOB ADDRESS ON THEM, | | | PER 2004 WPB AMEND. 106.1.3. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2009-05-01 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-05-01 |
Time |
12:00 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-05-01 |
Time |
12:00 |
Sent To |
|
|
| Notes |
| 2009-05-01 12:01:16 | REVISION OK -- SANITARY RISER DIAGRAM SHT A-06 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2008-10-06 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-10-06 |
Time |
15:45 |
Rev Time |
0.30 |
| Received By |
mperson |
Date |
2008-10-06 |
Time |
15:45 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2008-07-03 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-07-03 |
Time |
09:26 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-07-03 |
Time |
09:26 |
Sent To |
B |
|
| Notes |
| 2008-07-03 09:58:18 | PLUMBING PLAN REVIEW: | | | DENIED: | | | | | | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | | GAS/PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE. | | | | | | 1. THE ENERGY CALCULATIONS NEED TO BE SIGNED BY | | | OWNER/AGENT, PER FBC- 2004 SECTION 13-103.3. | | | | | | 2. THE ENERGY CALCULATIONS FAIL TO HAVE THE WATER | | | HEATER. THE NEW WATER HEATER FOR THE CABANA SHALL | | | COMPLY WITH FBC- 2004 TABLE 13-612.1.ABC.3.2 MINIMUM | | | PERFORMANCE STANDARDS WATER HEATING EQUIPMENT. | | | | | | 3. SHEET A-06 POOL CABANA PLUMBING RISER. PLEASE | | | CORRECT THE SANITARY RISER DIAGRAM PER FBC- PLUMBING | | | THE FOLLOWING SECTIONS. | | | | | | A} 917.7 VENT REQUIRED. WITHIN EACH PLUMBING SYSTEM, A | | | MINIMUM OF ONE VENT OR VENT STACK SHALL EXTEND OUTDOORS | | | TO THE OPEN AIR. THE SUBMITTED RISER DIAGRAM INDICATES | | | TWO STUDOR VENTS BEING INSTALLED WITH NO VENT OUTDOORS | | | TO OPEN AIR. | | | | | | B} PLEASE CLEARLY INDICATE THE CLEANOUT AT THE | | | JUNCTION OF THE BUILDING DRAIN AND BUILDING SEWER AS | | | BEING A TWO-WAY CLEANOUT. PER SECTION 708.3.5. | | | | | | ********IMPORTANT INFORMATION******** | | | WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE | | | OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW | | | PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | PHONE= (561) 805-6730 | | | FAX= (561) 805-6731 | | | E-MAIL= [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2009-05-14 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2009-05-14 |
Time |
13:54 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2009-05-14 |
Time |
11:56 |
Sent To |
|
|
| Notes |
| 2009-05-14 13:51:13 | NO 220V CONNECTIONS SHALL BE INSTALLED NOR A SEPARATE | | | IN ACCESSORY STRUCTURE - POOL CABANA. | | | | | | MAGGIE CRUZ, ASSOCIATE PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: (561) 822-1444 OR (561) 805-6720 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2008-10-01 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2008-10-01 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2008-10-01 |
Time |
10:52 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2008-06-27 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-06-27 |
Time |
14:29 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-06-27 |
Time |
14:29 |
Sent To |
E |
|
| Notes |
| 2008-06-27 14:32:37 | ***FAILED*** | | | | | | | | | 1)INDICATE SETBACK DIMENSIONS FROM PROPOSED A/C | | | EQUIPMENT TO ALL PROPERTY LINES.AS PER SECTION | | | 94-305(B)(4) OF THE CITY'S ZONING AND LAND DEVELOPMENT | | | REGULATIONS (ZLDRS): MECHANICAL EQUIPMENT MAY NOT | | | PROJECT MORE THAN 4 FEET INTO A REQUIRED SETBACK. | | | | | | 2)PROVIDE BEAR LAKES HOA APPROVAL. | | | | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, | | | ZONING TECHNICIAN (561)805-6720 | | | [email protected] | | | | | | | | | | | | | | | SENT TO "E" - SF RACK |
|
|