Plan Review Details - Permit 08060710
Plan Review Stops For Permit 08060710
Review Stop B BUILDING (STRUCTURAL)
Rev No 8 Status P Date 2008-11-05 Cont ID  
Sent By rmcdouga Date 2008-11-05 Time 13:52 Rev Time 0.00
Received By rmcdouga Date 2008-11-05 Time 13:52 Sent To  
Notes
2008-11-05 13:53:30ARCHITECTURAL DRAWING A110.3 WAS REVISED TO INDICATE
 REMOVAL OF ONE COLUMN RATHER THAN THE TWO ORIGINALLY
 SPECIFIED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 7 Status P Date 2008-11-05 Cont ID  
Sent By rmcdouga Date 2008-11-05 Time 13:37 Rev Time 0.00
Received By rmcdouga Date 2008-11-05 Time 13:37 Sent To  
Notes
2008-11-05 13:51:13SHORING PLANS REVISED TO CORRESPOND WITH ARCHITECTURAL
 AND STRUCTURAL DRAWINGS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status P Date 2008-11-05 Cont ID  
Sent By rmcdouga Date 2008-11-05 Time 13:36 Rev Time 0.00
Received By rmcdouga Date 2008-11-05 Time 13:34 Sent To  
Notes
2008-11-05 13:37:13SHEET S1 REVISED TO CORRESPOND WITH THE GRID LINES ON
 ARCHITECTURAL DRAWING.

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2008-10-31 Cont ID  
Sent By rmcdouga Date 2008-10-31 Time 15:32 Rev Time 0.00
Received By rmcdouga Date 2008-10-31 Time 15:32 Sent To  
Notes
2008-10-31 15:43:32SUBMITTAL OF SIGNED AND SEALED CALCULATIONS FOR
 TRANSFERED LOADS RESULTING FROM REMOVAL OF ONE SECOND
 FLOOR COLUMN.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status N Date 2008-10-29 Cont ID  
Sent By rmcdouga Date 2008-10-29 Time 07:26 Rev Time 0.00
Received By rmcdouga Date 2008-10-29 Time 07:26 Sent To  
Notes
2008-10-29 07:41:46SUBMITTAL DENIED
  
 1) THE SHORING PLAN SUBMITTAL THAT WAS SUBMITTED DOES
 NOT CORRESPOND TO SHEET S1 OF THE STRUCTURAL DRAWINGS.
 THE COLUMN GRID LINES FOR THE LOCATION OF THE COLUMN TO
 BE REPLACED ARE DIFFERENT.
  
 2) THIS PROJECT HAS BEEN DETERMINED TO BE A THRESHOLD
 BUILDING UNDER FS 553.71(7) . THEREFORE, THREE (3) SETS
 OF DRAWINGS ARE REQUIRED. FBC 109.3.6* CITY AMENDMENTS
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2008-10-28 Cont ID  
Sent By rmcdouga Date 2008-10-28 Time 10:52 Rev Time 0.00
Received By rmcdouga Date 2008-10-28 Time 10:52 Sent To  
Notes
2008-10-28 10:54:20REVISED SHEET S1 TO REMOVE ONLY ONE COLUMN AND PROVIDED
 ADDITIONAL DETAILS FOR INFILL OF STAIR OPENING.
 ARCHITECTURAL SHEET A110.3 ALSO NEEDS TO BE REVISED TO
 INDICATE THAT ONLY ONE COLUMN IS BEING REMOVED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2008-07-22 Cont ID  
Sent By rmcdouga Date 2008-07-21 Time 07:37 Rev Time 0.00
Received By rmcdouga Date 2008-07-21 Time 07:37 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-07-11 Cont ID  
Sent By rmcdouga Date 2008-07-11 Time 15:48 Rev Time 0.00
Received By rmcdouga Date 2008-07-11 Time 15:48 Sent To  
Notes
2008-07-11 15:48:312004 FBC W/2007 REVISIONS
 STRUCTURAL STEEL WORK
  
 DENIED BY BUILDING
  
 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT WILL
 BE REQUIRED.
  
 2) SUBMIT TWO SETS OF ARCHITECTURAL DRAWINGS SHOWING
 LOCATION OF COLUMN LINES OR PROVIDE A KEY PLAN
 IDENTIFYING THE LOCATION IN THE BUILDING WHERE THIS
 WORK IS TO BE PERFORMED. FBC 106.1.1* CITY AMENDMENTS
 AND FBC 1603.1
  
 3) THE DESIGN LOADS NOTE ON S1 REFERENCES THE 2001 FBC.
 PLEASE REVISED TO 2004 FBC.
  
 4) DETAIL 1 IS SPECIFIED WHERE THE COLUMN WITH THE 52
 KIPS POINT LOAD IS TO BE REMOVED. DETAIL 1 DOES NOT
 CORRESPOND TO THIS LOCATION. PLEASE REVISE.
  
 5) INDICATE ON THE ROOF PLAN THE LOCATION OF DETAIL 4.
 THIS APPEARS TO BE THE DETAIL FOR THE LOCATIONS WHERE
 THE TWO COLUMNS WILL BE REMOVED. PLEASE CLARIFY.
  
 6) PROVIDE A KEY PLAN OR SUBMIT ARCHITECTURAL DRAWINGS
 SPECIFYING THE LOCATION OF THE NEW 6" CONCRETE SLAB
 SHOWN ON THE SECOND FLOOR PLAN ON S1. PROVIDE
 DIMENSIONS OF THE NEW SLAB.FBC 106.1.1* CITY
 AMENDMENTS AND FBC 1603.1
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status N Date 2008-06-30 Cont ID  
Sent By btrobaug Date 2008-06-30 Time 14:29 Rev Time 0.00
Received By btrobaug Date 2008-06-30 Time 14:26 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status N Date 2008-07-09 Cont ID  
Sent By mwennerg Date 2008-07-09 Time 11:15 Rev Time 0.00
Received By mwennerg Date 2008-07-09 Time 11:15 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2008-11-13 Cont ID  
Sent By adarroug Date 2008-11-13 Time 14:02 Rev Time 0.00
Received By adarroug Date 2008-11-13 Time 14:02 Sent To P
Notes
2008-11-13 14:02:39TO "P" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2008-11-13 Cont ID  
Sent By adarroug Date 2008-11-13 Time 13:48 Rev Time 0.00
Received By adarroug Date 2008-11-13 Time 13:48 Sent To M
Notes
2008-11-13 13:48:54TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2008-11-13 Cont ID  
Sent By adarroug Date 2008-11-13 Time 13:43 Rev Time 0.00
Received By adarroug Date 2008-11-13 Time 13:43 Sent To E
Notes
2008-11-13 13:43:54TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2008-11-05 Cont ID  
Sent By adarroug Date 2008-11-05 Time 09:29 Rev Time 0.00
Received By adarroug Date 2008-11-05 Time 09:29 Sent To B
Notes
2008-11-05 09:30:22TO "RMCDOUGAL" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2008-10-24 Cont ID  
Sent By adarroug Date 2008-10-24 Time 08:58 Rev Time 0.00
Received By adarroug Date 2008-10-24 Time 08:58 Sent To B
Notes
2008-10-24 08:59:06TO "RMCDOUGAL" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-07-18 Cont ID  
Sent By adarroug Date 2008-07-18 Time 10:10 Rev Time 0.00
Received By adarroug Date 2008-07-18 Time 10:10 Sent To B
Notes
2008-07-18 10:10:49TO "RMCDOUGAL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-07-11 Cont ID  
Sent By rmcdouga Date 2008-07-11 Time 15:48 Rev Time 0.00
Received By rmcdouga Date 2008-06-25 Time 14:28 Sent To  
Notes
2008-06-26 12:57:38TO "BOB"#13
2008-06-25 14:29:16WAITING FOR "BOB"W/INTERIOR DEMO PERMIT.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2008-11-22 Cont ID  
Sent By rregueir Date 2008-11-22 Time 11:46 Rev Time 0.00
Received By rregueir Date 2008-11-22 Time 11:45 Sent To  
Notes
2008-11-22 11:46:30MECH REVISION SUBMITTED FOR STRUCTURE ONLY PERMIT. FEES
 AND REVISION NEED TO BE APPLIED TO REMODEL PERMIT
 #08070127

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2008-06-26 Cont ID  
Sent By tgordon Date 2008-06-26 Time 16:12 Rev Time 0.15
Received By tgordon Date 2008-06-26 Time 16:12 Sent To  
Notes
2008-06-26 16:13:17NO MECHANICAL PLANS SUBMITTED, AND NO
 MECHANICAL PERMIT NUMBER APPLIED FOR AT
 THIS TIME.

Review Stop P PLUMBING
Rev No 1 Status N Date 2008-07-02 Cont ID  
Sent By mperson Date 2008-07-02 Time 15:38 Rev Time 0.00
Received By mperson Date 2008-07-02 Time 15:38 Sent To  
Notes
2008-07-02 15:41:20NOTE: NO PLUMBING PLAN OR PERMIT APPLICATION FOR THIS
 PERMIT. THIS PERMIT FOR STRUCTURAL ONLY.

Review Stop Z ZONING
Rev No 1 Status N Date 2008-06-26 Cont ID  
Sent By choops Date 2008-06-26 Time 14:30 Rev Time 0.00
Received By choops Date 2008-06-26 Time 14:30 Sent To  
Notes
2008-06-26 14:31:02*ZONING REVIEW NOT REQUIRED: INTERIOR WORK ONLY AND THE
 VALUE OF PROPOSED WORK DOES NOT EXCEED 50% OF THE
 IMPROVEMENT VALUE.


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved