Plan Review Details - Permit 08060709
| Plan Review Stops For Permit 08060709 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2008-07-11 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2008-07-11 |
Time |
13:24 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2008-07-11 |
Time |
13:24 |
Sent To |
|
|
| Notes |
| 2008-07-11 13:24:28 | BUILDING PROVISO | | | | | | 1) THE BUSINESS CAN NOT BE OPEN DURING DEMOLITION AS | | | REQUIRED MEANS OF EGRESS ARE BEING AFFECTED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2008-06-30 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-06-30 |
Time |
14:57 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-06-30 |
Time |
14:57 |
Sent To |
|
|
| Notes |
| 2008-06-30 14:56:33 | | | | | | | | | | | | | PLEASE NOTE AN ELECTRICAL PERMIT IS REQUIRED FOR THE | | | SCOPE OF WORK PURPOSED. 105.1 FBC AS AMENDED.AN | | | ELECTRICAL CONTRACTOR MUST REMOVE ALL WIRING IN | | | AFFECTED AREAS FOR DEMOLITION AND MAKE SAVE SAME.ALL | | | TEMPORARY WIRING FOR THIS DEMOLITION SHALL COMPLY WITH | | | ARTICLE 590 NEC. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2008-07-09 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-07-09 |
Time |
11:04 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-07-09 |
Time |
11:04 |
Sent To |
|
|
| Notes |
| 2008-07-09 11:05:01 | DEMO ONLY |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-07-11 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2008-07-11 |
Time |
13:24 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2008-06-25 |
Time |
14:30 |
Sent To |
|
|
| Notes |
| 2008-06-26 12:57:58 | TO "BOB"#13 | | 2008-06-25 14:30:26 | WAITING FOR "BOB" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2008-06-26 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-06-26 |
Time |
16:13 |
Rev Time |
0.15 |
| Received By |
tgordon |
Date |
2008-06-26 |
Time |
16:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2008-07-02 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-07-02 |
Time |
15:13 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-07-02 |
Time |
15:13 |
Sent To |
|
|
| Notes |
| 2008-07-02 15:15:19 | ******PROVISO****** | | | PER FBC-2004 PLUMBING, SECTION 704.5 DEAD ENDS: IN THE | | | REMOVAL OF ANY PART OF A DRAINAGE SYSTEM, DEAD ENDS | | | SHALL BE PROHIBITED. A PLUMBING PERMIT IS REQUIRED AND | | | AN INSPECTION IS REQUIRED OF PLUMBING DEMO WORK PRIOR | | | TO COVERING DEMO WORK WITH FINNISH WALLS, CIELINGS, OR | | | POURED CONCRETE SLABS. | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL: [email protected] |
|
|
|