| 2008-07-03 16:36:17 | |
| | |
| | DENIED |
| | |
| | 1)PLANS AND SPECIFICATIONS DESIGN PARAMETERS SHALL |
| | COMPLY WITH THE 2004 FLORIDA BLDG CODE WITH 2006 & |
| | 2007AMENDMENTS PER 106.1.1 FBC* |
| | |
| | 2)IN AN EXISTING BUILDING WHERE ALTERATIONS ARE BEING |
| | MADE A DESIGN PROFESSIONAL MUST ELECT THE LEVEL OF |
| | ALTERATION PER 301.5 OF EXISTING BUILDING CODE AND |
| | STATE ALONG WITH THE TYPE OF CONSTRUCTION ON THE |
| | DRAWINGS |
| | |
| | 3)THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS |
| | LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS |
| | AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST |
| | EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS ICC |
| | (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES |
| | PER 108.3 FBC* |
| | |
| | 4)THE STATE OF FLORIDA REQUIRES COLLECTION OF A RADON |
| | SURCHARGE ON ALL NEW CONSTRUCTION COMPUTED ON UNDER |
| | ROOF FLOOR SPACE PER 10D-91 FAC. THESE FEES WILL BE |
| | ADDED TO THE PERMIT APPLICATION FEES |
| | |
| | |
| | NOTE: FEES ARE DUE IN THE AMOUNT OF $215.68 FOR |
| | INCREASED VALUE AND STATE RADON FEES THIS AMOUNT IS |
| | REQUIRED TO BE PAID PRIOR TO FURTHER PLAN REVIEW |
| | |
| | 5)PROVIDE 2 COPIES OF A RECENT SURVEY SHOWING THE |
| | PROPOSED BUILDING/ADDITION WITH ALL SIDE AND REAR |
| | SETBACKS, PLEASE NOTE THAT SURVEY AND SITE PLAN |
| | MEASUREMENTS ARE NOT THE SAME |
| | |
| | 6)PROVIDE A SITE PLAN THAT SHOWS DRAINAGE IN |
| | COMPLIANCE WITH THE REQUIREMENTS OF R403.1 FBC RES. |
| | |
| | 7)SUBMIT TWO COPIES OF ENERGY CALC'S PER 13-101.2.2 |
| | FBC. BE SURE THAT THEY ARE SIGNED AND DATED BY PREPARER |
| | AND OWNER/AGENT PRIOR |
| | TO SUBMITTAL. |
| | |
| | 8)CORRECTIONS ARE REQUIRED IN THE SUMMER AND WINTER |
| | AS-BUILT CALCULATIONS,INCORRECT INFORMATION FOR |
| | NUMBER OF GLAZED OPENINGS, ORIENTATION, OVERHANG |
| | LENGTHS AND HEIGHTS |
| | |
| | 9)PROVIDE SMOKE ALARMS TO EXISTING BUILDING PER |
| | R313.1.1 FBC RES. |
| | |
| | 10)BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, |
| | IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY. THE |
| | ACTUAL PERMIT SETS OF PLANS MUST BE STAMPED BY THAT |
| | OFFICE, AND A COPY OF THE PAID RECEIPT ATTACHED TO THE |
| | PERMIT APPLICATION. PLEASE CALL (561) 233-5025 FOR MORE |
| | INFORMATION |
| | |
| | 11)SUBMIT 2 COPIES OF ENGINEERED TRUSS DRAWINGS THAT |
| | COMPLY WITH R802.10.1 FBC WITH PERMIT APPLICATION OR |
| | BEFORE INSTALLATION THAT HAVE BEEN REVIEWED AND |
| | APPROVED BY THE DESIGNER OF RECORD |
| | |
| | 12)A DESIGN PROFESSIONAL THAT IS REGISTERED TO |
| | PRACTICE UNDER CHAPTER 481 OR 471 OF THE FLORIDA |
| | STATUTES SHALL AFFIX THEIR OFFICIAL SEAL, SIGNATURE AND |
| | DATE TO SAID DRAWINGS AND SPECIFICATIONS PER 106.1 FBC |
| | 2004. PHOTO COPIED, STAMPED OR REPRODUCED SIGNATURES |
| | ARE NOT ACCEPTABLE PER 471.025 F.S. THESE REPRODUCED |
| | SIGNATURES ARE PRESENT ON THE SOIL REPORT AND THE TRUSS |
| | ENGINEER INDEX SHEETS |
| | |
| | 13)AN ENGINEER PRACTICING THROUGH A DULYAUTHORIZED |
| | ENGINEERING BUSINESS SHALL INDICATE THEIR NAME AND |
| | LICENSE #, AS WELL AS THE NAME, ADDRESS AND CERTIFICATE |
| | OF AUTHORIZATION #ON EACH SHEET PER 61G15-23.002 (2) |
| | FAC. THE SOIL REPORT ENGINEERING DOES NOT CONTAIN THE |
| | REQUIRED CA # |
| | |
| | 14)PROVIDE MEAN ROOF HEIGHT ON ELEVATION DRAWINGS |
| | |
| | 15)PROVIDE ATTIC ACCESS ON DRAWINGS TO ALL NEW ROOF |
| | AREAS AS REQUIRED PER R807.1 FBC RES. |
| | |
| | 16)PROVIDE MIN ROOF SHEATHING ATTACHMENT PER |
| | R803.2.3.1 FBC RES. |
| | |
| | 17)PROVIDE ENGINEERED SUBSTRATE ATTACHMENT FOR WOOD |
| | BUCKS PER 1714.5.4.1 FBC |
| | |
| | 18)THE PERMIT APPLICATION SHALL INCLUDE TWO COPIES OF |
| | EACH PRODUCT APPROVAL THAT IS RELEVANT PER 9B-72. THESE |
| | SHOULD INCLUDE THE FLORIDA STATE APPROVAL COVER PAGES. |
| | ALL CAN BE FOUND ON WWW.FLORIDABUILDING.ORG |
| | |
| | 19)THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE |
| | 9B-72 (PRODUCT APPROVALS) SHALL BE REVIEWED AND |
| | APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO |
| | SUBMITTAL FOR JURISDICTIONAL APPROVAL PER 106.3.3 FBC* |
| | |
| | 20)THE CITY OF WEST PALM BEACH REQUIRES THE FLORIDA |
| | STATE PRODUCT APPROVAL SHEETS WHEN AVAILABLE. THEY CAN |
| | BE SEARCHED FOR ON WWW.FLORIDABUILDING.ORG.WHEN |
| | AVAILABLE AND NOT SUBMITTED APPLICATIONS WILL BE |
| | DENIED |
| | |
| | 21)NO PRODUCT APPROVALS WERE SUBMITTED FOR NEW |
| | SWINGING GARAGE DOOR, LINTELS AND CONNECTORS AND |
| | STRAPS. IN LUE OF PRODUCT APPROVALS STRAPS/CONNECTORS |
| | MAY BE LISTED IN A SCHEDULE ON THE DRAWINGS COMPLETE |
| | WITH THE STATEWIDE PRODUCT APPROVAL NUMBERS OR SUBMIT |
| | SIMPSON TIE'S COMPLETE FLORIDA INDEX WITH CONNECTORS TO |
| | BE USED HIGHLIGHTED |
| | |
| | 22)PRODUCT APPROVAL FOR THE METAL ROOF DOES NOT HAVE |
| | THE COMPLIANCE/INSTALLATION REPORT, LOAD TABLES AND |
| | EVALUATION REPORT FROM THE LINK ON PAGE 2 |
| | |
| | 23)PROVIDE TRUSS UPLIFT ANCHOR SCHEDULE, ENGINEERING |
| | DOES NOT PROVIDE THIS INFORMATION, ONLY THE AMOUNT OF |
| | UPLIFT AT THE BEARING LOCATIONS |
| | |
| | 24)PROVIDE DETAILS FOR ATTACHMENT OF THE COPULAS TO |
| | THE ROOF |
| | |
| | 25)PROVIDE SCHEDULE FOR PRECAST LINTEL THAT WILL BE |
| | USED AND OPENING SIZES TO COMPLY WITH 2104.1.5 FBC FOR |
| | MIN BEARING |
| | |
| | 26)ADDITIONAL PERMITS WILL BE REQUIRED FOR PLUMBING, |
| | ELECTRICAL, MECHANICAL, ROOFING AND DRIVEWAY |
| | |
| | |
| | BLDG PLAN REVIEW |
| | ADRIAN MORSE |
| | 561-805-6716 |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |