Plan Review Details - Permit 08060347
Plan Review Stops For Permit 08060347
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2008-12-04 Cont ID  
Sent By mjacobs Date 2008-11-26 Time 16:04 Rev Time 0.00
Received By mjacobs Date 2008-11-26 Time 16:03 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2008-09-11 Cont ID  
Sent By mjacobs Date 2008-09-11 Time 10:11 Rev Time 0.00
Received By mjacobs Date 2008-09-11 Time 09:03 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2008-08-13 Cont ID  
Sent By mjacobs Date 2008-08-13 Time 16:07 Rev Time 0.00
Received By mjacobs Date 2008-08-13 Time 07:50 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-06-23 Cont ID  
Sent By mjacobs Date 2008-06-23 Time 10:36 Rev Time 0.00
Received By mjacobs Date 2008-06-23 Time 08:04 Sent To PC
Notes
2008-06-23 10:36:22BUILDING PLAN REVIEW
 PERMIT: 08060347
 ADD: 7800 S. DIXIE HWY
 CONT: J. PALMER INC.
 TEL: (561)848-7114
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 6-23-08
 REVIEW: 1ST
 ACTION: DENIED
  
 1)INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE
 INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 2) PLEASE SUBMIT 2 COPIES OF PLANS, REPORTS, PRODUCT
 APPROVALS AND OR SUBMITTALS FOR REVIEW FOR PERMIT.
 106.1* /2004 SUBMITTAL DOCUMENTS WEST PALM BEACH
 ADMINISTRATIVE CODE.
  
 3)PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW)
 AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC
 BUILDING WITH THE 2007 SUPPLEMENTS. INDICATE THE USE
 AND OCCUPANCY OF THE BUILDING PER CHAPTER 3 AND THE
 BUILDING CONSTRUCTION TYPE PER CHAPTER 6 AND TABLE
 503.
  
 4)A DESIGN PROFESSIONAL THAT IS REGISTERED TO
 PRACTICE UNDER CHAPTER 481 OR 471 OF THE FLORIDA
 STATUTES SHALLAFFIX THEIR OFFICIAL SEAL, SIGNATURE
 AND DATE TO SAID DRAWINGS AND SPECIFICATION PER 106.1
 FBC 2004, THE EXEMPTION FROM LICENSURE UNDER 481.229
 FLORIDA STATUTES DOES NOT EXEMPT THE DESIGNER
 RESPONSIBLE FOR THE DRAWINGS FROM SIGNING AND DATING
 SAID DRAWINGS.
  
 5)106.1.1 CONSTRUCTION DOCUMENTS SHALL BE OF
 SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND
 EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT
 WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS.
  
 6)THE LETTER FROM PERMIT ENGINEERING SERVICES, INC.
 NEEDS TO SHOW THE CORRECT ADDRESS OF THE BUILDING. THE
 LETTER REFERS TO LAKE WORTH AS THE CITY. A PROFESSIONAL
 ENGINEER SHALL SIGN HIS NAME AND AFFIX HIS SEAL TO ALL
 PLANS, SPECIFICATIONS, REPORTS, FINAL BID DOCUMENTS
 PROVIDED TO THE OWNER OR THE OWNER?S REPRESENTATIVE, OR
 OTHER DOCUMENTS PREPARED OR ISSUED BY SAID REGISTRANT
 AND BEING FILED FOR PUBLIC RECORD. IF PRACTICING
 THROUGH A DULY AUTHORIZED ENGINEERING BUSINESS, THE
 NAME, ADDRESS AND CERTIFICATE OF AUTHORIZATION NUMBER
 SHALL BE INDICATED ON EACH SHEET. ALL THE INFORMATION
 IN THE LETTER FROM THE ENGINEERING FIRM SHALL BE SHOWN
 IN DETAIL ON ARCHITECTURAL PLANS.61G15-23.002
  
 7)A CERTIFIED ROOFING CONTRACTOR SHALL BE RESPONSIBLE
 FOR ALL ROOFING WORK.
 ROOFING PERMIT; ONLY CHECKED ITEMS APPLY
  
 _XX 1) CONTRACTOR IS TO PROVIDE THE FOLLOWING
 INFORMATION ON THE APPLICATION, SEE ATTACHED POLICY:
 MEAN ROOF HEIGHT/ ROOF PITCH / ROOF DECK TYPE / AREA OF
 EACH ROOF TYPE
  
 _XX 2) FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED
 IN ADDITION TO THE EVALUATION REPORT SUBMITTED,
 FAC9B72.WWW.FLORIDABUILDING.ORG
  
 _XX 3) FOR THE FLAT DECK, SELECT THE APPROVED ASSEMBLY
 YOU ARE USING.ALSO INDICATE WHICH FASTENER IF THE
 OPTIONS HAVE DIFFERENT PRESSURE LIMITATIONS.
  
 _XX 4) FOR THE FLAT DECK, SPECIFY THE ENHANCED
 FASTENING FOR CORNER AND PERIMETER ZONES.
  
 _XX 5) SEE PRODUCT LIMITATION #7.CALCULATIONS
 PREPARED BY AN ARCHITECT, ENGINEER, OR REGISTERED ROOF
 CONSULTANT REQUIRED FOR ENHANCED FASTENING.
  
 8)106.3.3*THOSE PRODUCTS WHICH ARE REGULATED BY DCA
 RULE 9B-72 SHALL BE REVIEWED AND APPROVED IN WRITING BY
 THE DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL. USING THE INFORMATION FROM THE
 PRODUCT APPROVALS, CIRCLE OR HI-LIGHT WHICH DOOR AND
 WINDOW WILL BE INSTALLED,
  
 9)STATE THE R-VALUE FOR THE INSULATION WHICH WILL BE
 INSTALLED IN THE ATTIC. 13-604.1
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 (561)805-6726
 [email protected]

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2008-12-04 Cont ID  
Sent By btrobaug Date 2008-12-04 Time 12:29 Rev Time 0.00
Received By btrobaug Date 2008-12-04 Time 12:15 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2008-09-04 Cont ID  
Sent By btrobaug Date 2008-09-04 Time 15:13 Rev Time 0.00
Received By btrobaug Date 2008-09-04 Time 14:58 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2008-08-15 Cont ID  
Sent By btrobaug Date 2008-08-15 Time 15:35 Rev Time 0.00
Received By btrobaug Date 2008-08-15 Time 15:31 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2008-06-16 Cont ID  
Sent By btrobaug Date 2008-06-16 Time 10:42 Rev Time 0.00
Received By btrobaug Date 2008-06-16 Time 10:40 Sent To  
Notes
2008-06-16 10:42:38 
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE
 CYCLES:
  
 THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2004
 RESIDENTIAL BUILDING CODE, 2005 NEC, 2004 FBC CHAPTER 1
 AS AMENDED AND FOUND NONCOMPLIANT WITH THE FOLLOWING:
  
 1} AN ELECTRICAL PERMIT IS REQUIRED PER 105.1 FBC AS
 AMENDED.
  
 2} THE PERSON TAKING RESPONSIBILITY FOR THE DESIGN MUST
 PRINT AND SIGN THEIR NAME TO SAME, ALL SHEETS, PER
 106.1.3.FBC.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status P Date 2008-12-02 Cont ID  
Sent By mawillia Date 2008-12-02 Time 14:56 Rev Time 0.00
Received By mawillia Date 2008-12-02 Time 14:49 Sent To  
Notes
2008-12-02 14:54:05*****REVISION #2, DATED 11/13/2008, APPROVED*****
  
  
 REVISED PLAN SHEET A1 OF 2 WAS STAMPED, INITIALED, AND
 DATED.

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2008-09-11 Cont ID  
Sent By mwennerg Date 2008-09-11 Time 10:30 Rev Time 0.00
Received By mwennerg Date 2008-09-11 Time 10:30 Sent To B
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2008-08-11 Cont ID  
Sent By mawillia Date 2008-08-11 Time 15:12 Rev Time 0.00
Received By mawillia Date 2008-08-11 Time 14:53 Sent To  
Notes
2008-08-11 15:11:40*****DENIED*****
  
 THE FOLLOWING COMMENTS TAKEN FROM THE PREVIOUS FIRE
 PLAN REVIEW STILL NEEDS TO BE ADDRESSED:
  
  
 1.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR
 DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241.
  
 2.COMBUSTIBLE WASTE MATERIALS, DUST, AND DEBRIS SHALL
 BE REMOVED FROM THE SITE DAILY.
  
 3.THE SCOPE OF WORK SHALL NOT HINDER OR INTERFERE
 WITH ACCESS TO / EGRESS FROM OTHER GUEST ROOMS OF THE
 BUILDING.
  
 4.NFPA 101, LIFE SAFETY CODE, 2003 EDITION SHALL BE
 REFERENCED IN GENERAL;IN PARTICULAR CHAPTER 29 -
 EXISTING HOTELS AND DORMITORIES.
  
 7.DOORS THAT OPEN ONTO EXIT ACCESS CORRIDORS SHALL
 HAVE NOT LESS THAN A 20-MINUTE FIRE-RATING.
  
 8.DOORS THAT OPEN ONTO EXIT ACCESS CORRIDORS SHALL BE
 SELF-CLOSING AND SELF-LATCHING.
  
  
 TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE
 LETTER INDICATING WHERE ON THE APPROPIATE PLAN SHEET
 EACH COMMENT WAS ADDRESSED
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2008-06-19 Cont ID  
Sent By mawillia Date 2008-06-19 Time 15:17 Rev Time 0.00
Received By mawillia Date 2008-06-19 Time 14:28 Sent To  
Notes
2008-06-19 14:59:30*****DENIED*****
  
 NOTE:THE LETTER RECEIVED FROM PERMIT ENGINEERING
 SEVICES INC REFERENCES THE AQUA MOTEL ADDRESSED IN LAKE
 WORTH, FLORIDA.PLEASE BE ADVISED THIS BUILDING IS IN
 THE JURISDICTION OF THE CITY OF WEST PALM BEACH.
  
  
 1.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR
 DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241.
  
 2.COMBUSTIBLE WASTE MATERIALS, DUST, AND DEBRIS SHALL
 BE REMOVED FROM THE SITE DAILY.
  
 3.THE SCOPE OF WORK SHALL NOT HINDER OR INTERFERE
 WITH ACCESS TO / EGRESS FROM OTHER GUEST ROOMS OF THE
 BUILDING.
  
 4.NFPA 101, LIFE SAFETY CODE, 2003 EDITION SHALL BE
 REFERENCED IN GENERAL;IN PARTICULAR CHAPTER 29 -
 EXISTING HOTELS AND DORMITORIES.
  
 5.SPECIFY THE WALL AND CEILING FINISH MATERIALS IN
 TERMS OF CLASS A, CLASS B, OR CLASS C.
  
 6.SHOW THE LOCATION OF THE SMOKE ALARM IN THIS GUEST
 ROOM.AN APPROVED SINGLE-STATION SMOKE ALARM SHALL BE
 INSTALLED IN GUEST ROOM AND EVERY LIVING AREA AND
 SLEEPING ROOM WITHIN A GUEST SUITE.
  
 7.DOORS THAT OPEN ONTO EXIT ACCESS CORRIDORS SHALL
 HAVE NOT LESS THAN A 20-MINUTE FIRE-RATING.
  
 8.DOORS THAT OPEN ONTO EXIT ACCESS CORRIDORS SHALL BE
 SELF-CLOSING AND SELF-LATCHING.
  
  
 TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE
 LETTER INDICATING WHERE ON THE APPROPIATE PLAN SHEET
 EACH COMMENT WAS ADDRESSED
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2008-11-18 Cont ID  
Sent By adarroug Date 2008-11-18 Time 14:26 Rev Time 0.00
Received By adarroug Date 2008-11-18 Time 14:26 Sent To  
Notes
2008-11-21 16:48:54TO "BOB"#11
2008-11-18 14:26:30WAITING FOR "BOB"

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2008-09-02 Cont ID  
Sent By adarroug Date 2008-09-02 Time 11:07 Rev Time 0.00
Received By adarroug Date 2008-09-02 Time 11:07 Sent To  
Notes
2008-09-02 11:10:23TO "BOB"#15

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-07-28 Cont ID  
Sent By adarroug Date 2008-07-28 Time 14:35 Rev Time 0.00
Received By adarroug Date 2008-07-28 Time 14:35 Sent To  
Notes
2008-08-08 13:15:43TO "BOB"#10
2008-07-28 14:35:38WAITING FOR "BOB"

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-07-28 Cont ID  
Sent By adarroug Date 2008-06-23 Time 14:34 Rev Time 0.00
Received By adarroug Date 2008-06-13 Time 09:13 Sent To  
Notes
2008-06-13 09:20:15TO "BOB"#6

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2008-06-16 Cont ID  
Sent By tgordon Date 2008-06-16 Time 16:17 Rev Time 0.20
Received By tgordon Date 2008-06-16 Time 16:17 Sent To  
Notes
2008-06-16 16:20:23NO MECHANICAL PLANS SUBMITTED, AND NO
 MECHANICAL PERMIT NUMBER APPLIED FOR AT
 THIS TIME.
  
 *** NOTICE ***
 1) BEFORE DOING ANY MECHANICAL (A/C) WORK, A MECHANICAL
 PERMIT WILL BE REQUIRED AND MECHANICAL PLANS
 SUBMITTED.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]

Review Stop Z ZONING
Rev No 1 Status N Date 2008-06-16 Cont ID  
Sent By choops Date 2008-06-16 Time 10:06 Rev Time 0.00
Received By choops Date 2008-06-16 Time 10:06 Sent To  
Notes
2008-06-16 10:06:27*ZONING REVIEW NOT REQUIRED: INTERIOR WORK ONLY AND THE
 VALUE OF PROPOSED WORK DOES NOT EXCEED 50% OF THE
 IMPROVEMENT VALUE.