Plan Review Details - Permit 08060343
Plan Review Stops For Permit 08060343
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-06-16 Cont ID  
Sent By jwitmer Date 2008-06-16 Time 08:31 Rev Time 2.22
Received By jwitmer Date 2008-06-16 Time 08:31 Sent To  
Notes
2008-06-16 08:54:53BUILDING PLAN REVIEW
 PERMIT: 08060343
 ADD: 550 S ROSEMARY AVE # 244
 CONT: FOUR CORNERS CONSTRUCTION
 TEL: (5112)796-8400
  
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 1STREVIEW
 ACTION: DENIED
  
 1A)INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE
 INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 1B) INFORMATIONAL: PLEASE SUBMIT 2 OF ALL SURVEYS,
 PLANS, REPORTS, REVISIONS , PRODUCT APPROVALS AND OR
 SUBMITTALS FOR REVIEW FOR PERMIT. IF YOUR PROJECT WILL
 REQUIRE A RESIDENT INSPECTOR OR IF YOUR PROJECT IS A
 THRESHOLD BUILDING REQUIRING A THRESHOLD INSPECTOR THEN
 (3) THREE SETS OF ALL SAID DOCUMENTS WILL BE REQUIRED
 FOR PERMIT ISSUANCE. 106.1* /2004 SUBMITTAL DOCUMENTS
 WEST PALM BEACH ADMINISTRATIVE CODE.
  
 1C)INFORMATIONAL106.1.1* W.P.B. ADMINISTRATIVE
 CODE/2004 DRAWINGS & SPECIFICATIONS SHALL CONTAIN
 INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, AS TO
 THE QUALITY OF MATERIALS, WHERE QUALITY IS ESSENTIAL TO
 CONFORMITY WITH THE TECHNICAL CODES. SUCH INFORMATION
 SHALL BE SPECIFIC TO THE TECHNICAL CODES "SHALL NOT BE
 CITED AS A WHOLE OR IN PART, NOR THE TERM "LEGAL" OR
 ITS EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC
 INFORMATION". CONSTRUCTION DOCUMENTS SHALL BE
 SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND
 EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT
 WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL.
  
 1D ) INFORMATIONAL FL S S 713.13NOTICE OF
 COMMENCEMENT, TO BE FILED WITH THE CLERK OF THE COURT.
 NOTE: 713.13(2) IF THE WORK DESCRIBED IN THE NOTICE OF
 COMMENCEMENT IS NOT ACTUALLYCOMMENCED WITHIN 90 DAYS
 AFTER THE RECORDING THEREOF, SUCH NOTICE IS NULL &
 VOID. NOTE: 713.13(6) THE POSTING OF THE NOTICE OF
 COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE THE FIRST
 INSPECTION.
  
 1E)INFORMATIONAL: PLANS SUBMITTED FOR PERMIT (FIRST
 TIME REVIEW) AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO
 THE 2004 FBC BUILDING WITH THE2007 SUPPLEMENTS.
  
 2)PERMIT APPLICATION INDICATES THIS IS A
 RE-CONFIGURATION OF THE EXTERIOR BAR LOCATION. PLANS
 FAIL TO PROVIDE THE LOCATION OF THE BAR IN REGARDS TO
 THE EXTERIOR PATIO. PLEASE PROVIDE THE LOCATION WITH
 OTHER
 TABLES AND CHAIR LOCATION EGRESS AISLES ETC, 1024.9.1.
  
 3) THE PLANS FAIL TO INDICATE HOW COMPLIANCE WITH
 11-5.2 WILL BE COMPLIED WITH, PLEASE PROVIDE ADDITIONAL
 INFORMATION, IT WILL BE GREATLY APPRCIATED .
  
 4) BOTH THE ELECTRICAL NOTES AS WELL AS THE PLUMBING
 NOTES INDICATE SEE ARCHITECTURAL PLANS THE VALUE OF
 THIS PROJECT IS INDICATED TO BE $75,000.00, PLEASE SEE
  
 FLORIDA STATE STATUTE 481.229 (C)ANY OTHER TYPE OF
 BUILDING COSTING LESS THAN $25,000, EXCEPT A SCHOOL,
 AUDITORIUM, OR OTHER BUILDING INTENDED FOR PUBLIC USE,
 PROVIDED THAT THE SERVICES OF A REGISTERED ARCHITECT
 SHALL NOT BE REQUIRED FOR MINOR SCHOOL PROJECTS
 PURSUANT TO S. 1013.45. PLANS ARE REQUIRED TO BE
 DESIGNED BY EITHER A ARCHITECT OR ENGINEER.
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)659-8026
 E-MAIL: [email protected]
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2008-06-20 Cont ID  
Sent By dpalmer Date 2008-06-20 Time 11:23 Rev Time 0.00
Received By dpalmer Date 2008-06-20 Time 11:23 Sent To  
Notes
2008-06-20 11:23:18** DENIEDREVIEW **
  
  
 1) NOTE: PLEASE SUBMIT COMPLETE ELECTRICAL PLANS FOR
 SCOPE OF WORK BEING DONE.
 PLEASE KNOW PLANS SHALL BE DONE AT A MINIMUM BY AN
 ARCHITECT FOR PROPOSED SCOPE PER FS 481.229.
 PLEASE SHOW COMPLIANCE FOR SCOPE OF WORK WITH THE 2005
 NFPA-70, 2003 NFPA-101 AND 2002 NFPA-72 ALONG WITH 2004
 FBC W/2007 REVISIONS.
 FOOD SERVICE PLANS ARE NOT ACCEPTABLE IN LIEU OF
 MINIMUM PLANS AS REQUIRED BY THE FBC ADMIN SECTIONS
 106.1, 106.1.2, 106.3.5.1.2.
  
  
  
 ** IMPORTANT**
 ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP
 FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE
 ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING.
 DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS.
 PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY
 ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS,
 SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO
 TWO SETS/FOLDERS/BINDERS ETC.
 PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS
 SHOULD BE SUBMITTED FOR REFERENCE.
 THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID
 ANY DELAYS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR REVIEW. IF
 THERE ARE ANY QUESTIONS OR COMMENTS PLEASE DO NOT
 HESITATE IN CONTACTING THIS OFFICE.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2008-06-20 Cont ID  
Sent By mawillia Date 2008-06-20 Time 11:53 Rev Time 0.00
Received By mawillia Date 2008-06-20 Time 11:40 Sent To  
Notes
2008-06-20 11:52:05*****DENIED*****
  
  
 1.THE ACTUAL PROJECT SITE ADDRESS, INCLUDING SUITE
 NUMBER, SHALL BE IN THE TITLE BLOCK OF EACH SUBMITTED
 PLAN SHEET.
  
 2.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR
 DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241.
  
 3.COMBUSTIBLE WASTE MATERIALS, DUST, AND DEBRIS SHALL
 BE REMOVED FROM THE SITE AT THE END OF EACH SHIFT OR
 MORE FREQUENTLY AS NECESSARY FOR SAFE OPERATION.
  
 4.THE SCOPE OF WORK SHALL NOT HINDER OR INTERFERE
 WITH ACCESS TO / EGRESS FROM OTHER SUITES ON THE SECOND
 FLOOR OR IN THE BUILDING.
  
 5.PROVIDE A LAYOUT OF THIS EXTERIOR BAR IN REFERENCE
 TO ITS LOCATION TO THE SUITE / FLOOR / BUILDING.
  
  
 TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE
 LETTER INDICATING WHERE ON THE PLAN EACH COMMENT WAS
 ADDRESSED
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-06-20 Cont ID  
Sent By mawillia Date 2008-06-20 Time 11:40 Rev Time 0.00
Received By mawillia Date 2008-06-13 Time 09:30 Sent To  
Notes
2008-06-13 09:30:37TO "COMM" BD#57--EXPEDITED--

Review Stop P PLUMBING
Rev No 1 Status F Date 2008-06-18 Cont ID  
Sent By kstevens Date 2008-06-18 Time 10:52 Rev Time 0.00
Received By kstevens Date 2008-06-18 Time 10:51 Sent To  
Notes
2008-06-18 11:12:24DENIED
 REFERENCE: FBC-2004 PLUMBING W/2007 REVISIONS
 FBC-2004 CHAPTER 11
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 1. PLANS ARE REQUIRED TO BE DRAWN/DESIGNED BY A DESIGN
 PROFESSIONAL, (ARCHITECT OR ENGINEER) PER FS 481.229(C)
 & SECTION 106.1.
  
 2. SUBMIT AN EXISTING FLOOR PLAN SHOWING THE LOCATION
 OF THE BAR TO BE DEMO'D AND INDICATE WHICH PIPING SHALL
 BE DEMO'D TO DETERMINE THE SCOPE OF WORK. SECTION
 106.1.2.
  
 3. SUBMIT AN ISOMETRIC WATER RISER DIAGRAM AND AN
 ISOMETRIC SANITARY RISER DIAGRAM THAT REFLECTS THE
 FLOOR PALN. SECTION 106.3.5.1.3. FOR THE WATER RISER
 DIAGRAM SHOW ALL PIPE SIZES, VALVES & (WHERE REQUIRED
 BY SECTION 604.9) WATER HAMMER ARRESTORS. SECTION
 601.1. FOR THE SANITARY RISER DIAGRAM SHOW ALL PIPE
 SIZES, VENTS, TRAPS ETC. SECTIONS 701.1, 710.1, 901.1 &
 1001.1. APPROVED INDIRECT WASTE RECEPTORS ARE FLOOR
 SINKS OR HUB DRAINS PER SECTIONS 802.3 & 802.3.2. FLOOR
 DRAINS ARE NOT APPROVED INDIRECT WASTE RECEPTORS. THE
 AIR GAPS SHALL COMPLY WITH SECTION 802.2.1. INDICATE
 THE CONNECTION LOCATION FOR THE WATER AND THE SANITARY
 SYSTEMS TO THE EXISTING SYSTEMS.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE, IDENTIFYING
 THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]
  

Review Stop Z ZONING
Rev No 1 Status F Date 2008-06-19 Cont ID  
Sent By eschneid Date 2008-06-19 Time 08:55 Rev Time 0.00
Received By eschneid Date 2008-06-19 Time 08:55 Sent To  
Notes
2008-06-19 09:01:07FAILED
  
 THE SCOPE OF WORK IS FOR DEMOLITION AND RECONSTRUCTION.
 THE FOLLOWING SHALL BE PROVIDED:
  
 A. A SITE PLAN SHOWING THE BAR TO BE DEMOLISHED.
  
 B. A SITE PLAN SHOWING THE NEW BAR IN RELATION (WITH
 DIMENSIONS) TO THE BUILDING FACE, THE PATIO AREA, ETC.
  
 CONATCT ERIC SCHNEIDER @ (561) 822-1435.