Plan Review Details - Permit 08060245
Plan Review Stops For Permit 08060245
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2008-08-07 Cont ID  
Sent By lmartine Date 2008-08-07 Time 14:50 Rev Time 0.00
Received By lmartine Date 2008-08-07 Time 14:50 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2008-08-06 Cont ID  
Sent By shill Date 2008-08-06 Time 12:29 Rev Time 0.00
Received By shill Date 2008-08-06 Time 12:29 Sent To  
Notes
2008-08-06 12:31:39****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC*
 CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FACFLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 FROM PREVIOUS LIST:
  
 XX__3.PROVIDE A COPY OF THE CONDO ASSOCIATION
 APPROVAL.
  
 PLEASE PROVIDE AS REQUESTED.PER BUILDING OFFICIAL, AS
 THE APPLICANT (THE UNIT OWNER) DOES NOT OWN THE OUTSIDE
 OF THE BUILDING (OWNED BY CONDO ASSOCIATION), APPROVAL
 BY THE CONDO ASSOCIATION IS REQUIRED.THIS IS REQUIRED
 IN THE CASE OF PROPOSED CONDOMINIUM IMPROVEMENTS TO THE
 OUTSIDE OUT THE BUILDING WHEN THE APPLICANT IS NOT THE
 ASSOCIATION.IT DOES NOT APPLY TO INTERIOR RENOVATIONS
 IN CONDOMIUMNS OR TO R3 IMPROVEMENTS.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-06-12 Cont ID  
Sent By shill Date 2008-06-12 Time 11:52 Rev Time 0.00
Received By shill Date 2008-06-12 Time 11:52 Sent To  
Notes
2008-06-12 11:53:50****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC*CITY OF WEST PALM BEACH AMENDMENTS TO THE
 FBC2004
 FACFLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 ***WINDOW OR DOOR PERMIT APPLICATION, ONLY CHECKED
 ITEMS APPLY***
  
 ____1.A NOTICE OF COMMENCEMENT MUST BE FILED WITH
 THE CLERK OF COURTS PRIOR TO PERMIT PICKUP, FS713.13.
  
 _XX_2.PROVIDE BUILDING HEIGHT.DESIGN PRESSURES
 FOR BUILDINGS OVER 60FEET ARE REQUIRED TO BE DESIGNED
 USING ASCE7, FBC1609.1.1. DOCUMENTS PREPARED BY AN
 ENGINEER AND SUBMITTED FOR PUBLIC RECORD ARE TO BE
 SIGNED SEALED ORIGINALS FAC61G15-23.002.ENGINEERING
 IS TO STATE WHETHER THIS OPENING IS IN ZONE 4 OR ZONE
 5.
  
 XX__3.PROVIDE A COPY OF THE CONDO ASSOCIATION
 APPROVAL.
  
 ____4.IMPACT PROTECTION REQUIRED,FBC1609.1.4, FBC R
 301.2.1.2.PROVIDE PRODUCT APPROVALS AND, IF SHUTTERS
 ARE USED, COMPLETE THE ATTACHED INSTALLATION SCHEDULE.
 IF THIS FALLS UNDER THE 25% EXCEPTION FBC EB 507.3,
 PROVIDE CALCULATIONS.
  
 _XX_5.FLORIDA STATE OR LOCAL PRODUCT APPROVAL
 REQUIRED, FAC9B72, WWW.FLORIDABUILDING.ORG.THIS IS IN
 ADDITION TO THE NOA PROVIDED.
  
 ____6.PROVIDE A FLOOR PLAN SHOWING: WINDOW
 LOCATIONS, SIZES, WINDOW TYPE, ROOM DESIGNATIONS.NOTE
 EXISTING CONDITIONS (TYPE OF WINDOW) AND OPENING SIZE
 FOR BEDROOMS, FBC R310, FBC EB 505.1.
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-07-30 Cont ID  
Sent By adarroug Date 2008-07-30 Time 10:15 Rev Time 0.00
Received By adarroug Date 2008-07-30 Time 10:15 Sent To B
Notes
2008-07-30 10:16:00TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-06-12 Cont ID  
Sent By shill Date 2008-06-12 Time 11:53 Rev Time 0.00
Received By shill Date 2008-06-10 Time 09:14 Sent To  
Notes
2008-06-10 09:14:57TO "MISC" BOX#1


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved