Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-06-18 Cont ID  
Sent By adarroug Date 2008-06-18 Time 12:14 Rev Time 0.00
Received By adarroug Date 2008-06-18 Time 12:14 Sent To P
Notes
2008-06-18 12:15:11TO "P" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-06-11 Cont ID  
Sent By mperson Date 2008-06-11 Time 10:16 Rev Time 0.00
Received By mperson Date 2008-06-10 Time 09:55 Sent To PC
Notes
2008-06-10 09:55:16TO "G" BOX

Review Stop P PLUMBING
Rev No 2 Status P Date 2008-06-19 Cont ID  
Sent By mperson Date 2008-06-19 Time 10:42 Rev Time 0.00
Received By mperson Date 2008-06-19 Time 10:42 Sent To PC
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2008-06-11 Cont ID  
Sent By mperson Date 2008-06-11 Time 09:47 Rev Time 0.00
Received By mperson Date 2008-06-11 Time 09:47 Sent To I
Notes
2008-06-11 10:16:30PLUMBING PLAN REVIEW:
 DENIED:
  
 PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH
 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO
 CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE
 (F.A.C.), AND FLORIDA STATUTES (F.S.).
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE.
  
 1. DRAWINGS SUBMITTED IN PENCIL ARE UNACCEPTABLE. PER
 (W.P.B. AS AMENDED) SECTION 106.1.3 QUALITY OF BUILDING
 PLANS. THE BUILDING OFFICIAL MAY ESTABLISH THROUGH
 DEPARTMENTAL POLICY, STANDARDS FOR PLANS AND
 SPECIFICATIONS, IN ORDER TO PROVIDE CONFORMITY TO ITS
 RECORD RETENTION
 PROGRAM. THIS POLICY MAY INCLUDE SUCH THINGS AS MINIMUM
 SIZE, SHAPE, CONTRAST, CLARITY, OR OTHER ITEMS RELATED
 TO RECORDS MANAGEMENT.
 NOTE: ONE DRAWING WAS IN PENCIL.
  
 2. NOTE: ALL PLANS, SPECIFICATIONS, AND ACCOMPANYING
 DATA BEING FILED FOR PUBLIC RECORD SHALL CONTAIN THE
 PRINTED NAME OF THE RESPONSIBLE PERSON WITH THE
 ORIGINAL SIGNATURE AND DATE ON SUCH INFORMATION. PER
 SECTION *106.3.4.3.
 IF THE DESIGN PROFESSIONAL IS AN ARCHITECT OR
 ENGINEER, THEN HE OR SHE SHALL AFFIX HIS OR HER
 OFFICIAL SEAL, SIGNATURE AND DATE TO SAID DRAWINGS, PER
 FLORIDA STATUTES 481 AND 471 RESPECTIVELY.
  
 3. PERMIT APPLICATION STATES "REPLACE EXISTING 4" MAIN
 SEWER LINE UP TO 20 FEET" HOWEVER THE SUBMITTED PLAN IS
 INDICATING INSIDE A BUILDING "4" CAST IRON REPLACEMENT
 WITH 4" PVC 20 FT". FOR ALL PRACTICAL PURPOSES AND
 CLARIFICATION OF EXACTLY WHERE THE PIPING THAT IS GOING
 TO BE REPLACED LOCATION IS THE FBC-2004 PLUMBING
 CHAPTER 2 DEFINITIONS WILL BE USED. PLEASE REFERENCE
 THE FOLLOWING DEFINITIONS OF A BUILDING DRAIN AND
 BUILDING SEWER AND PLEASE CORRELATE THE PERMIT AND
 PLANS ACCORDINGLY.
  
 BUILDING DRAIN. THAT PART OF THE LOWEST PIPING OF A
 DRAINAGE SYSTEM THAT RECEIVES THE DISCHARGE FROM SOIL,
 WASTE AND OTHER DRAINAGE PIPES INSIDE AND THAT EXTENDS
 30 INCHES (762 MM) IN DEVELOPED LENGTH OF PIPE BEYOND
 THE EXTERIOR WALLS OF THE BUILDING AND CONVEYS THE
 DRAINAGE TO THE BUILDING SEWER.
 SANITARY . A BUILDING DRAIN THAT CONVEYS SEWAGE ONLY.
  
 BUILDING SEWER. THAT PART OF THE DRAINAGE SYSTEM THAT
 EXTENDS FROM THE END OF THE BUILDING DRAIN AND CONVEYS
 THE DISCHARGE TO A PUBLIC SEWER, PRIVATE SEWER,
 INDIVIDUAL SEWAGE DISPOSAL SYSTEM OR OTHER POINT OF
 DISPOSAL.
 SANITARY . A BUILDING SEWER THAT CONVEYS SEWAGE ONLY.
  
 4. PER FS 713.13 (1) THRU (6): A NOTICE OF
 COMMENCEMENT IS REQUIRED FROM THE - PALM BEACH COUNTY
 COURTHOUSE - 4TH FLOOR RECORDING DEPT. 205 N. DIXIE
 HWY., BEFORE A PERMIT CAN BE ISSUED. PER FS 713.13 (2):
 IF THE IMPROVEMENT DESCRIBED IN THE NOTICE OF
 COMMENCEMENT IS NOT ACTUALLY COMMENCED WITHIN 90 DAYS
 AFTER THE RECORDING THEREOF, SUCH NOTICE IS VOID AND OF
 NO FURTHER EFFECT.
  
 ********IMPORTANT INFORMATION********
 WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE
 OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW
 PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 END OF COMMENTS:
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 PHONE= (561) 805-6730
 FAX= (561) 805-6731
 E-MAIL= [email protected]